AAA2000CE8

Panasonic
R134a DG series
Performance & dimensions
Application: Low back pressure
Refrigerant: R134a (CF3CH2F)
Evaporator temp range: -35°C to -5 °C
Rated voltage
Model
Voltage range
ASHRAE
/ Frequency
50Hz
Capacity
60Hz
COP - W/W
Capacity
COP – W/W
W
kcal/hr
RSIR
RSCR
W
kcal/hr
RSIR
RSCR
100V
DG51C90RA00
145
125
-
1.49
176
151
-
1.56
50Hz/60Hz
DG57C96RA00
168
144
-
1.50
202
174
-
1.57
DG57C12GAT6
202
174
1.42
-
88V-121V
DG66C10RAT6
242
208
-
1.62
99V-121V
DG51C69RAU6
176
151
-
1.63
DG51C72RAU6
176
151
-
1.61
DG57C84RAU6
202
174
-
1.64
DG66C10RAU6
242
208
-
1.68
DG73C12RAU6
279
240
-
1.68
DG86C15RAU6
325
280
-
1.67
110V 60Hz
115V 60Hz
DG77C16GAX5
225
194
1.40
-
DG91C21RAX5
259
223
1.40
1.46
DG51C89RAW5
145
125
-
1.53
DG57C96RAW5
168
144
-
1.58
220V-240V
DG66C11RAW5
187
161
-
1.60
50Hz
DG73C12RAW5
212
182
-
1.62
DG77C14RAW5
225
194
-
1.62
DG91C18RAW5
259
223
-
1.58
220V 50Hz
Condition
ASHRAE
90V-110V
103V-127V
170V-250V
187V-255V
CECOMAF
Condensing temperature:
54.4 °C
55 °C
Evaporating temperature:
-23.3 °C
-25 °C
Gas superheated to:
32.2 °C
32 °C
Liquid subcooled to:
32.2 °C
55 °C
Ambient temperature:
32.2 °C
32 °C
Notes: All data covered by this catalogue are given as general information only.
Since we are constantly improving our products, as the specifications and availability are subject to change without notice
Panasonic
R134a DG series
Performance & dimensions
Appearance - representative
Rated voltage
Model
/ Frequency
Name
Cooling type
100V
DG51C90RA00
ST
50Hz/60Hz
DG57C96RA00
ST
DG57C12GAT6
110V 60Hz
115V 60Hz
220V 50Hz
Dimension -mm
Mount
A
B
C
Dia.-mm
Pitch-mm
185.4
189.6
195.6
Ø16 * 4
70 * 170
ST
185.4
187.0
195.6
Ø16 * 4
70 * 170
DG66C10RAT6
OC
185.4
203.8
212.4
Ø19 * 4
101.6 * 165.1
DG51C69RAU6
ST/FC
DG51C72RAU6
ST/FC
DG57C84RAU6
ST/FC
DG66C10RAU6
ST/FC
184.6
198.8
211.0
Ø19 * 4
101.6 * 165.1
DG73C12RAU6
ST/FC
DG86C15RAU6
ST/FC
DG77C16GAX5
OC
DG91C21RAX5
OC
184.6
212.4
221
DG51C89RAW5
ST
185.4
187
195.6
DG57C96RAW5
ST/FC
185.4
197.8
206.4
DG66C11RAW5
ST/FC
220V-240V
DG73C12RAW5
ST
50Hz
DG77C14RAW5
ST
DG91C18RAW5
ST
DG73C12RAW5
DG77C14RAW5
185.4
206.8
215.4
OC
185.4
203.8
212.4
OC
185.4
212.8
221.4
Ø16 * 4
70 * 170
Ø19 * 4
101.6 * 165.1
Ø16 * 4
Ø19 * 4
70 * 170
101.6 * 165.1
Note) Compressor cooling: ST = Static cooling, FC = Fan cooling, OC = Oil cooling
Tube dimension - representative
Rated voltage
/ Frequency
ID / OD -mm
Location of
Dis.
Suc.
Pro.
100V 50Hz/60Hz
4.9 / 7.0
6.5 / 8.3
6.5 / 8.3
110V 60Hz
4.9 / 7.0
6.5 / 8.3
6.5 / 8.3
115V 60Hz
6.5 / 8.3
8.1 / 10
6.5 / 8.3
220V-240V 50Hz
4.9 / 7.0
6.5 / 8.3
6.5 / 8.3
Oil cooler
4.9 / 7.0
Suction tube
Discharge tube side
4.9 / 7.0
Notes: All data covered by this catalogue are given as general information only.
Since we are constantly improving our products, as the specifications and availability are subject to change without notice
Panasonic
R134a DG series
Performance & dimensions
110V 60Hz
220V-240V 50Hz
Oil cooling
110V 60Hz
220V-240V 50Hz
115V 60Hz
A
Pro.
A
A
Suc.
Suc.
Suc.
Dis.
Pro.
Dis.
Pro.
233mm
233mm
225mm
B
C
Dis.
B
B
C
C
Oil cooler
Notes: All data covered by this catalogue are given as general information only.
Since we are constantly improving our products, as the specifications and availability are subject to change without notice
Panasonic
R134a DG series
Performance & dimensions
Notes: All data covered by this catalogue are given as general information only.
Since we are constantly improving our products, as the specifications and availability are subject to change without notice