DBZ 012058 Datasheet

DBZ 012058
www.vishay.com
Vishay Draloric
RF Power Feed-Through Capacitors
with Screw Terminals, Class 1 Ceramic
FEATURES
• Small size
• Geometry minimizes inductance
APPLICATIONS
Filtering purposes in industrial and medical RF power
equipment.
CAPACITANCE RANGE
200 pF
CAPACITANCE TOLERANCE
- 10 % + 20 %
QUICK REFERENCE DATA
CERAMIC DIELECTRICS
DESCRIPTION
VALUE
Ceramic Class
1
Ceramic Dielectric
Type
R85
DBZ 012058
R85 (TCC - 750 ppm/K)
RATED VOLTAGE
7.5 kVp
Voltage (Vp)
7500
Min. Capacitance (pF)
200
DIELECTRIC STRENGTH TEST
Max. Capacitance (pF)
200
12.5 kVDC, 1 minute
Mounting
Screw terminal
MATERIAL
Capacitor elements made from class 1 ceramic dielectric
with noble metal electrodes.
DISSIPATION FACTOR
Max. 0.05 % (1 MHz)
INSULATION RESISTANCE
Connection terminals:
thread terminal, copper / brass, silver plated
Min. 100 000 M (at 25 °C)
Allowable torque: 3.5 Nm (13 lbf in)
OPERATING TEMPERATURE RANGE
FINISH
-55 °C to +100 °C
Capacitor body completely protective lacquered.
MARKING
Type designator, capacitance value and tolerance, rated
peak voltage, ceramic material code, production date code,
manufacturer logo
Revision: 02-Sep-15
Document Number: 22101
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
DBZ 012058
www.vishay.com
Vishay Draloric
SAP PART NUMBER AND ELECTRICAL DATA
PART NUMBER
CERAMIC
CAP.
VALUES
(pF)
RATED
VOLTAGE
(kVP)
RATED
POWER (1)
(kvar)
RATED
CURRENT
(ARMS)
FEED-THROUGH
CURRENT (2)
(A)
R85
200
7.5
5.0
4.0
7.0
DBZ12058VZ20172BJ1
Notes
(1) The surface temperature during operation must not exceed +100 °C
(2) DC or low frequency RMS current (< 20 kHz)
20 ± 1
(0.79 ± 0.04)
28.0 + 0.5
(1.102 + 0.020)
Ø 3.3 + 0.2
(0.130 + 0.008 Dia.)
Ø 14
(0.55 Dia.)
Ø 12
(0.47 Dia.)
0.5
(0.020)
22.0 ± 0.2
(0.866 ± 0.008)
DIMENSIONS in millimeters (inches)
=
=
58 + 2
(2.28 + 0.08)
M4 threads both ends
62 max.
(2.44 max.)
DERATING DIAGRAM
0.14 MHz
Ug (kVp)
10
Ig (ARMS)
Qg (kvar)
10
2.54 MHz
Ug
Qg
1
1
Ig
0.1
0.01
0.1
0.1
1
10
100
Frequency (MHz)
RELATED DOCUMENTS
General Information
Revision: 02-Sep-15
www.vishay.com/doc?22071
Document Number: 22101
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000