Wall Plug - Ins WDU18-300 Electrical Specifications (@25C) 1. Primary Rating: 120V 60Hz 9W 2. Primary Excitation Current: 75mA Max 3. Secondary Rating: 18VDC ± 5%, 300mADC 4. Secondary No-Load Rating: 24.20VDC Ref. 5. Output Ripple Voltage: 1280mV Max 6. Operating Temperature Range: -10 Deg C to +40 Deg C 7. Temperature Rise: 75 Deg C Max at rated load 50 Deg C Max on enclosure surface Mechanical Parameters: Case Type: Thermoplastic molded enclosure. Output Cord: 24 AWG, 6 Ft. Long Min. Agency File: UL/CUL: File E245587, UL 1310 A. Dimensions: H W D 70 50 41 *Units: In Millimeter B. Schematic: Technical Note: 1. Inside (tip)-positive (+), outside-negative (-) U.S. DOE Compliance per Sec. 301 of EISA 2007: As of July 1, 2008, this product is intended for use as follows: 1. Requires Federal Food and Drug Administration listing and approval as a medical device in accordance with section 513 of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. 360c) 2. Powers the charger of a detachable battery pack or charges the battery of a product that is fully or primarily motor operated. 3. As a service part or a spare part for an end-use product manufactured before July 1, 2008, that constitutes the primary load of this power supply. RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013