Wall Plug - Ins WDU18-250 Electrical Specifications (@25C) 1. Primary Rating: 120V 60Hz 12.0W 2. Primary Excitation Current: 60mA Max 3. Secondary Rating: 18VDC ± 5%, 250mADC 4. Secondary No-Load Rating: 26.5VDC Ref. 5. Output Ripple Voltage: 800mV Max 6. Operating Temperature Range: -10 Deg C to +40 Deg C 7. Temperature Rise: 70 Deg C Max at rated load 50 Deg C Max on enclosure surface Mechanical Parameters: Case Type: Thermoplastic molded enclosure. Output Cord: 24 AWG, 6 Ft. Long Min. Agency File: UL/CUL: File E104603, UL 1310 CSA: LR67888 A. Dimensions: H W D 64 51 41 *Units: In Millimeter 120V 60HZ 1000uF/35V B. Schematic: Technical Note: 1. Inside (tip)-positive (+), outside-negative (-) U.S. DOE Compliance per Sec. 301 of EISA 2007: As of July 1, 2008, this product is intended for use as follows: 1. Requires Federal Food and Drug Administration listing and approval as a medical device in accordance with section 513 of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. 360c) 2. Powers the charger of a detachable battery pack or charges the battery of a product that is fully or primarily motor operated. 3. As a service part or a spare part for an end-use product manufactured before July 1, 2008, that constitutes the primary load of this power supply. NAMEPLATE MARKING AC ADAPTOR MODEL: WDU18-250 INPUT: 120V 60Hz 12W OUTPUT: 18.0VDC .25A CLASS 2 TRANSFORMER LISTED UL R R AEC-T4118A 16UO E104603 RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. LR67888 MADE IN CHINA * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013