Spec in PDF

AZ
AZ2501L
60 AMP LATCHING
POWER RELAY
FEATURES
•
•
•
•
•
•
60 Amp switching
Heavy loads to 15000 VA
Inrush current 500A/2ms max.
4 kV dielectric
Manual switch standard
UL, CUR file E44211
GENERAL DATA
CONTACTS
Arrangement
SPST (1 Form A) (1 Form B)
Ratings
Resistive load:
Max.
Max.
Max.
Max.
UL/CUR
switched power: 15000 VA
switched current: 60 A
switched voltage: 440 VAC
continuous current: 20 A
20 A at 277 VAC, Resistive, 85°C, 100k cycles
20 A at 30 VDC, Resistive, 85°C, 100k cycles
60 A at 250 VAC, General use, 85°C 30k cycles
5000 W at 250 VAC, Tungsten, 30k cycles
20 A at 277 VAC, Standard Ballast, 30k cycles
16 A at 277 VAC, Electronic Ballast, 30k cycles
Material
Silver tin oxide
Resistance
< 50 milliohms initially
(24 V, 1 A voltage drop method)
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 106
3 x 104 at rated load
Set and Reset
Pulse Duration
50 ms minimum
Set Time (typical)
15 ms at nominal coil voltage
Reset Time (typical)
15 ms at nominal coil voltage
Dielectric Strength
4000 Vrms coil to contact
(at sea level for 1 min.) 1500 Vrms between open contacts
Insulation
Resistance
1000 megohms min. at 20°C, 500 VDC,
50% RH
Creepage Distance
8 mm
Ambient Temperature
Operating
At nominal coil voltage
-40°C (-40°F) to 85°C (158°F)
Vibration
0.059" DA at 10–55 Hz
Shock
Operating
10 g
Non-Operating 100 g
COIL
Power
At Pickup Voltage
(typical)
.92 W single coil
1.8 W dual coil
Temperature
NOTES
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy
Max. Solder Temp.
270°C (518°F)
Max. Solder Time
5 seconds
Weight
32 grams
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
12/16/13
AZ
AZ2501L
RELAY ORDERING DATA
COIL SPECIFICATIONS -Standard Single Coil
Nominal Coil
VDC
6
12
24
48
Must Operate
VDC
4.8
9.6
19.2
38.4
ORDER NUMBER*
Max. Continuous
VDC [1]
7.8
15.6
31.2
62.4
Coil Resistance
± 10%
22
100
360
1600
COIL SPECIFICATIONS -Standard Dual Coil
1 Form A
AZ2501LP1–1A–6D
AZ2501LP1–1A–12D
AZ2501LP1–1A–24D
AZ2501LP1–1A–48D
1 Form B
AZ2501LP1–-1B–6D
AZ2501LP1–-1B–12D
AZ2501LP1–-1B–24D
AZ2501LP1–-1B–48D
ORDER NUMBER*
Nominal Coil
Must Operate
Max. Continuous
Coil Resistance
VDC
VDC
VDC [1]
± 10%
6
4.8
7.8
11 + 11
12
9.6
15.6
50 + 50
24
19.2
31.2
180 + 180
48
38.4
62.4
800 + 800
* For reverse polarity coil add suffix “R”. NOTE: [1] Max. continuous voltage should not be applied for
1 Form A
AZ2501LP2–1A–6D
AZ2501LP2–1A–12D
AZ2501LP2–1A–24D
AZ2501LP2–1A–48D
more then 30 seconds
1 Form B
AZ2501LP2–-1B–6D
AZ2501LP2–-1B–12D
AZ2501LP2–-1B–24D
AZ2501LP2–-1B–48D
(Bottom View)
MECHANICAL DATA
If no tolerance is shown: outline dimension <= 1mm, tolerance is ±0.2mm; outline dimension > 1mm
and <=5mm, tolerance is ±0.3mm; outline dimension >5mm, tolerance is ±0.4mm.
12/16/13
AZ2501L
NOTE:
Regarding Standard Polarity type:
1. “Single Coil Latching Version”
(1) After energizing 1 (-) and 2 (+), 50ms pulse, terminal 3 and 4 is connected.
(2) After energizing 2 (-) and 1 (+), 50ms pulse, terminal 3 and 4 is disconnected.
2. “Double Coil Latching Version”
(1) After energizing 5 (+) and 1 (-), 50ms pulse, terminal 3 and 4 is connected.
(2) After energizing 5 (+) and 2 (-) , 50ms pulse, terminal 3 and 4 is disconnected.
Regarding Reverse Polarity type:
1. “Single Coil Latching Version”
(1) After energizing 1 (+) and 2 (-), 50ms pulse, terminal 3 and 4 is connected.
(2) After energizing 2 (+) and 1 (-), 50ms pulse, terminal 3 and 4 is disconnected.
2. “Double Coil Latching Version”
(1) After energizing 5 (+) and 2 (-), 50ms pulse, terminal 3 and 4 is connected.
(2) After energizing 5 (+) and 1 (-), 50ms pulse, terminal 3 and 4 is disconnected.
5/14/13