M39006/09, M39006/21 www.vishay.com Vishay Wet Tantalum Capacitors, Military Established Reliability, MIL-PRF-39006/09/21 Qualified Styles CLR65, CLR69 FEATURES • Hermetically sealed • Metal cased • Axial lead • Tubular STYLE, MILITARY SPECIFICATION • CLR65, M39006/09 MIL-PRF-39006/09 • CLR69, M39006/21 MIL-PRF-39006/21 PERFORMANCE CHARACTERISTICS Operating Temperature: -55 °C to +125 °C (above 85 °C, voltage derating is required) Capacitance Range: M39006/09 - 1.7 μF to 1200 μF; M39006/21 - 6.8 μF to 2200 μF Capacitance Tolerance: ± 5 %, ± 10 %, ± 20 % Voltage Rating: 6 VDC to 125 VDC For information on the performance characteristics of these capacitors, please refer to the latest issue of the military specification. Established Reliability Tantalum Capacitors to Military Specification MIL-PRF-39006: in accordance with the military specification MIL-PRF-39006 all capacitors are marked with the military part number (M39006/xx-xxxx) rather than the older style designation (CLR65, CLR69) and should be ordered as such. Each order for military style capacitors requiring government inspection must state whether inspection is to be at the destination or at the Vishay plant. Orders requiring source inspection cannot be shipped until this has been accomplished. ORDERING INFORMATION M39006 /09 -8005 BASIC DOCUMENT NUMBER SLASH SHEET DASH NUMBER Indicates the basic specification; in this case MIL-PRF-39006 Indicates the specification sheet of the basic military specification Taken from Standard/Extended Ratings tables Revison: 14-Jun-16 Document Number: 40159 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay DIMENSIONS in inches [millimeters] Style CLR65 Style CLR69 Tantalum feed-through 0.078 [1.98] max. dia. 0.250 [6.35] max. Terminal welded to case Term. loc. within 0.031 [0.79] R of true position - + D dia. Circuit diagram 0.094 [2.38] max. External weld E L Glass 0.025 ± 0.002 [0.64 ± 0.05] E Insulating sleeve BARE CASE CASE CODE T1 T2 T3 T4 WITH INSULATING SLEEVE D L D (Max.) L (Max.) E LEAD LENGTH 0.188 ± 0.016 [4.78 ± 0.41] 0.281 ± 0.016 [7.14 ± 0.41] 0.375 ± 0.016 [9.53 ± 0.41] 0.375 ± 0.016 [9.53 ± 0.41] 0.453 + 0.031/- 0.016 [11.51 + 0.79/- 0.41] 0.641 + 0.031/- 0.016 [16.28 + 0.79/- 0.41] 0.766 + 0.031/- 0.016 [19.46 + 0.79/- 0.41] 1.062 + 0.031/- 0.016 [26.97 + 0.79/- 0.41] 0.219 [5.56] 0.312 [7.92] 0.406 [10.31] 0.406 [10.31] 0.515 [13.08] 0.704 [17.88] 0.828 [21.03] 1.126 [28.60] 1.500 ± 0.250 [38.10 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] WEIGHT (oz./g) (Max.) 0.07 [2.0] 0.18 [5.1] 0.36 [10.2] 0.49 [13.9] RATINGS AND CASE CODES - M39006/09 μF 1.7 2.5 3.5 3.6 4.0 4.7 5.0 6.8 8.0 8.2 9.0 10 11 15 20 22 25 30 33 39 40 43 47 50 56 60 68 70 82 86 100 6 8 10 15 25 30 50 60 75 100 125 T1 T1 T1 T1 T1 T1 T1 T1 T1 T1 T2 T1 T1 T2 T1 T1 T2 T1 T2 T1 T2 T1 T2 T3 T1 T3 T1 T2 T2 T2 T3 T3 T1 T2 T3 T1 T3 T4 T3 T1 Revison: 14-Jun-16 T2 T3 T2 T3 T4 T2 T2 T3 Document Number: 40159 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay RATINGS AND CASE CODES - M39006/09 μF 110 120 140 150 160 170 180 220 250 270 300 330 350 390 430 540 560 750 850 1200 6 8 10 15 25 30 50 60 75 T4 100 125 75 100 125 T1 T2 T2 T4 T3 T4 T3 T2 T3 T2 T3 T2 T3 T4 T3 T4 T3 T3 T4 T3 T4 T4 T4 RATINGS AND CASE CODES - M39006/21 μF 6.8 10 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 6 8 10 15 25 30 50 60 T1 T1 T1 T2 T1 T2 T3 T1 T1 T3 T2 T1 T4 T2 T2 T4 T1 T1 T1 T2 T2 T3 T4 T3 T4 T3 T4 T2 T2 T3 T4 T2 T2 T3 T3 T4 T3 T4 T3 T4 T3 T4 T4 Revison: 14-Jun-16 Document Number: 40159 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR65 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/09FAILURE RATE LEVEL (%/1000 h) L 2.0 30 30 30 68 68 68 140 140 140 270 270 270 330 330 330 560 560 560 1200 1200 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8011 8012 8013 8014 8015 8016 8017 8018 8019 8020 25 25 25 56 56 56 220 220 220 430 430 430 850 850 T1 T1 T1 T1 T1 T1 T2 T2 T2 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8021 8022 8023 8024 8025 8026 8027 8028 8029 8030 8031 8032 8033 8034 20 20 20 47 47 47 100 100 100 180 180 180 250 250 250 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 8035 8036 8037 8038 8039 8040 8041 8042 8043 8044 8045 8046 8047 8048 8049 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/09-XXXX MAX. DF AT +25 °C (%) 6 VDC AT +85 °C; 4 VDC AT +125 °C 8206 1 2 9.1 8207 1 2 9.1 8208 1 2 9.1 8209 1 2 20.4 8210 1 2 20.4 8211 1 2 20.4 8212 1 3 21.3 8213 1 3 21.3 8214 1 3 21.3 8215 1 6.5 81.8 8216 1 6.5 81.8 8217 1 6.5 81.8 8218 2 7.9 49.6 8219 2 7.9 49.6 8220 2 7.9 49.6 8221 2 13 128 8222 2 13 128 8223 2 13 128 8224 3 14 144.4 8225 3 14 144.4 8 VDC AT +85 °C; 5 VDC AT +125 °C 8226 1 2 7.6 8227 1 2 7.6 8228 1 2 7.6 8229 1 2 17 8230 1 2 17 8231 1 2 17 8232 1 7 66.4 8233 1 7 66.4 8234 1 7 66.4 8235 2 14 91.5 8236 2 14 91.5 8237 2 14 91.5 8238 4 16 65.8 8239 4 16 65.8 10 VDC AT +85 °C; 7 VDC AT +125 °C 8240 1 2 6.1 8241 1 2 6.1 8242 1 2 6.1 8243 1 2 18.1 8244 1 2 18.1 8245 1 2 18.1 8246 1 4 15.2 8247 1 4 15.2 8248 1 4 15.2 8249 1 7 54.4 8250 1 7 54.4 8251 1 7 54.4 8252 2 10 37.8 8253 2 10 37.8 8254 2 10 37.8 MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 100 100 100 60 60 60 40 40 40 25 25 25 20 20 20 25 25 25 20 20 -40 -40 -40 -40 -40 -40 -40 -40 -40 -44 -44 -44 -44 -44 -44 -64 -64 -64 -80 -80 +10.5 +10.5 +10.5 +14 +14 +14 +14 +14 +14 +17.5 +17.5 +17.5 +14 +14 +14 +17.5 +17.5 +17.5 +25 +25 +12 +12 +12 +16 +16 +16 +16 +16 +16 +20 +20 +20 +16 +16 +16 +20 +20 +20 +25 +25 100 100 100 59 59 59 30 30 30 25 25 25 22 22 -40 -40 -40 -40 -40 -40 -44 -44 -44 -64 -64 -64 -80 -80 +10.5 +10.5 +10.5 +14 +14 +14 +17.5 +17.5 +17.5 +17.5 +17.5 +17.5 +25 +25 +12 +12 +12 +16 +16 +16 +20 +20 +20 +20 +20 +20 +25 +25 175 175 175 100 100 100 60 60 60 40 40 40 30 30 30 -32 -32 -32 -36 -36 -36 -36 -36 -36 -36 -36 -36 -40 -40 -40 +10.5 +10.5 +10.5 +14 +14 +14 +14 +14 +14 +14 +14 +14 +14 +14 +14 +12 +12 +12 +16 +16 +16 +16 +16 +16 +16 +16 +16 +16 +16 +16 Note Style CLR65 is inactive for new military design. For new design use style CLR79. (1) Revison: 14-Jun-16 Document Number: 40159 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR65 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/09FAILURE RATE LEVEL (%/1000 h) L 2.0 390 390 390 750 750 T3 T3 T3 T4 T4 20 10 5 20 10 8050 8051 8052 8053 8054 15 15 15 33 33 33 70 70 70 120 120 120 170 170 170 270 270 270 540 540 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8055 8056 8057 8058 8059 8060 8061 8062 8063 8064 8065 8066 8067 8068 8069 8070 8071 8072 8073 8074 10 10 10 22 22 22 100 100 100 180 180 180 350 350 T1 T1 T1 T1 T1 T1 T2 T2 T2 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8075 8076 8077 8078 8079 8080 8081 8082 8083 8084 8085 8086 8087 8088 8.0 8.0 8.0 15 15 15 40 40 40 T1 T1 T1 T1 T1 T1 T2 T2 T2 20 10 5 20 10 5 20 10 5 8089 8090 8091 8092 8093 8094 8095 8096 8097 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/09-XXXX MAX. DF AT +25 °C (%) 10 VDC AT +85 °C; 7 VDC AT +125 °C 8255 2 16 87.6 8256 2 16 87.6 8257 2 16 87.6 8258 4 16 56.5 8259 4 16 56.5 15 VDC AT +85 °C; 10 VDC AT +125 °C 8260 1 2 5.7 8261 1 2 5.7 8262 1 2 5.7 8263 1 2 12.5 8264 1 2 12.5 8265 1 2 12.5 8266 1 4 13.1 8267 1 4 13.1 8268 1 4 13.1 8269 1 7 36.8 8270 1 7 36.8 8271 1 7 36.8 8272 2 10 25.4 8273 2 10 25.4 8274 2 10 25.4 8275 2 16 60.9 8276 2 16 60.9 8277 2 16 60.9 8278 6 24 49 8279 6 24 49 25 VDC AT +85 °C; 15 VDC AT +125 °C 8280 1 2 4.6 8281 1 2 4.6 8282 1 2 4.6 8283 1 2 8.3 8284 1 2 8.3 8285 1 2 8.3 8286 1 10 31.4 8287 1 10 31.4 8288 1 10 31.4 8289 2 18 54.3 8290 2 18 54.3 8291 2 18 54.3 8292 7 28 35 8293 7 28 35 30 VDC AT +85 °C; 20 VDC AT +125 °C 8294 1 2 4.5 8295 1 2 4.5 8296 1 2 4.5 8297 1 2 9.1 8298 1 2 9.1 8299 1 2 9.1 8300 1 5 12.2 8301 1 5 12.2 8302 1 5 12.2 MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 25 25 25 23 23 -64 -64 -64 -80 -80 +17.5 +17.5 +17.5 +25 +25 +20 +20 +20 +25 +25 155 155 155 90 90 90 75 75 75 50 50 50 35 35 35 30 30 30 23 23 -24 -24 -24 -28 -28 -28 -28 -28 -28 -28 -28 -28 -32 -32 -32 -56 -56 -56 -80 -80 +10.5 +10.5 +10.5 +14 +14 +14 +14 +14 +14 +17.5 +17.5 +17.5 +14 +14 +14 +17.5 +17.5 +17.5 +25 +25 +12 +12 +12 +16 +16 +16 +16 +16 +16 +20 +20 +20 +16 +16 +16 +20 +20 +20 +25 +25 220 220 220 140 140 140 50 50 50 32 32 32 24 24 -16 -16 -16 -20 -20 -20 -28 -28 -28 -48 -48 -48 -70 -70 +8 +8 +8 +10.5 +10.5 +10.5 +13 +13 +13 +13 +13 +13 +25 +25 +9 +9 +9 +12 +12 +12 +15 +15 +15 +15 +15 +15 +25 +25 275 275 275 175 175 175 65 65 65 -16 -16 -16 -20 -20 -20 -24 -24 -24 +8 +8 +8 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +12 +12 +12 +12 +12 +12 +12 +12 +12 Note Style CLR65 is inactive for new military design. For new design use style CLR79. (1) Revison: 14-Jun-16 Document Number: 40159 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR65 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/09FAILURE RATE LEVEL (%/1000 h) L 2.0 68 68 68 100 100 100 150 150 150 300 300 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 8098 8099 8100 8101 8102 8103 8104 8105 8106 8107 8108 5.0 5.0 5.0 10 10 10 25 25 25 47 47 47 60 60 60 82 82 82 160 160 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125 8126 8127 8128 4.0 4.0 4.0 8.2 8.2 8.2 20 20 20 39 39 39 50 50 50 68 68 68 140 140 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 8129 8130 8131 8132 8133 8134 8135 8136 8137 8138 8139 8140 8141 8142 8143 8144 8145 8146 8147 8148 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/09-XXXX MAX. DF AT +25 °C (%) 30 VDC AT +85 °C; 20 VDC AT +125 °C 8303 1 8 31 8304 1 8 31 8305 1 8 31 8306 2 12 19 8307 2 12 19 8308 2 12 19 8309 2 18 46 8310 2 18 46 8311 2 18 46 8312 8 32 35 8313 8 32 35 50 VDC AT +85 °C; 30 VDC AT +125 °C 8314 1 2 3.4 8315 1 2 3.4 8316 1 2 3.4 8317 1 2 6 8318 1 2 6 8319 1 2 6 8320 1 5 11.2 8321 1 5 11.2 8322 1 5 11.2 8323 1 9 21.4 8324 1 9 21.4 8325 1 9 21.4 8326 2 12 13.6 8327 2 12 13.6 8328 2 12 13.6 8329 2 16 24.9 8330 2 16 24.9 8331 2 16 24.9 8332 8 32 25.7 8333 8 32 25.7 60 VDC AT +85 °C; 40 VDC AT +125 °C 8334 1 2 3 8335 1 2 3 8336 1 2 3 8337 1 2 5 8338 1 2 5 8339 1 2 5 8340 1 5 7.6 8341 1 5 7.6 8342 1 5 7.6 8343 1 9 20.7 8344 1 9 20.7 8345 1 9 20.7 8346 2 12 15.3 8347 2 12 15.3 8348 2 12 15.3 8349 2 16 30.7 8350 2 16 30.7 8351 2 16 30.7 8352 8 32 25.7 8353 8 32 25.7 MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 60 60 60 40 40 40 35 35 35 25 25 -24 -24 -24 -28 -28 -28 -48 -48 -48 -60 -60 +13 +13 +13 +10.5 +10.5 +10.5 +13 +13 +13 +25 +25 +15 +15 +15 +12 +12 +12 +15 +15 +15 +25 +25 400 400 400 250 250 250 95 95 95 70 70 70 45 45 45 45 45 45 27 27 -16 -16 -16 -24 -24 -24 -20 -20 -20 -28 -28 -28 -16 -16 -16 -32 -32 -32 -50 -50 +5 +5 +5 +8 +8 +8 +10.5 +10.5 +10.5 +13 +13 +13 +10.5 +10.5 +10.5 +13 +13 +13 +25 +25 +6 +6 +6 +9 +9 +9 +12 +12 +12 +15 +15 +15 +12 +12 +12 +15 +15 +15 +25 +25 550 550 550 275 275 275 105 105 105 90 90 90 50 50 50 50 50 50 28 28 -16 -16 -16 -24 -24 -24 -16 -16 -16 -28 -28 -28 -16 -16 -16 -32 -32 -32 -40 -40 +5 +5 +5 +8 +8 +8 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +10.5 +20 +20 +6 +6 +6 +9 +9 +9 +12 +12 +12 +12 +12 +12 +12 +12 +12 +12 +12 +12 +20 +20 Note Style CLR65 is inactive for new military design. For new design use style CLR79. (1) Revison: 14-Jun-16 Document Number: 40159 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR65 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/09FAILURE RATE LEVEL (%/1000 h) L 2.0 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/09-XXXX MAX. DF AT +25 °C (%) MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 75 VDC AT +85 °C; 50 VDC AT +125 °C 3.5 T1 20 8149 8354 1 2 2.5 650 -16 +5 +6 3.5 T1 10 8150 8355 1 2 2.5 650 -16 +5 +6 3.5 T1 5 8151 8356 1 2 2.5 650 -16 +5 +6 6.8 T1 20 8152 8357 1 2 4.1 300 -20 +8 +9 6.8 T1 10 8153 8358 1 2 4.1 300 -20 +8 +9 6.8 T1 5 8154 8359 1 2 4.1 300 -20 +8 +9 15 T2 20 8155 8360 1 5 7.5 150 -16 +8 +9 15 T2 10 8156 8361 1 5 7.5 150 -16 +8 +9 15 T2 5 8157 8362 1 5 7.4 150 -16 +8 +9 33 T2 20 8158 8363 1 10 17.5 90 -24 +10.5 +15 33 T2 10 8159 8364 1 10 17.5 90 -24 +10.5 +15 33 T2 5 8160 8365 1 10 17.5 90 -24 +10.5 +15 40 T3 20 8161 8366 2 12 15.2 60 -16 +10.5 +12 40 T3 10 8162 8367 2 12 15.2 60 -16 +10.5 +12 40 T3 5 8163 8368 2 12 15.2 60 -16 +10.5 +12 56 T3 20 8164 8369 2 17 26 60 -28 +10.5 +15 56 T3 10 8165 8370 2 17 26 60 -28 +10.5 +15 56 T3 5 8166 8371 2 17 26 60 -28 +10.5 +15 110 T4 20 8167 8372 9 36 25.7 29 -35 +20 +20 110 T4 10 8168 8373 9 36 25.7 29 -35 +20 +20 100 VDC AT +85 °C; 65 VDC AT +125 °C 2.5 T1 20 8169 8374 1 2 5 950 -16 +7 +8 2.5 T1 10 8170 8375 1 2 5 950 -16 +7 +8 2.5 T1 5 8171 8376 1 2 5 950 -16 +7 +8 4.7 T1 20 8172 8377 1 2 3.6 500 -16 +7 +8 4.7 T1 10 8173 8378 1 2 3.6 500 -16 +7 +8 4.7 T1 5 8174 8379 1 2 3.6 500 -16 +7 +8 11 T2 20 8175 8380 1 4 5 200 -16 +7 +8 11 T2 10 8176 8381 1 4 5 200 -16 +7 +8 11 T2 5 8177 8382 1 4 5 200 -16 +7 +8 22 T2 20 8178 8383 1 9 11.8 100 -16 +7 +8 22 T2 10 8179 8384 1 9 11.8 100 -16 +7 +8 22 T2 5 8180 8385 1 9 11.8 100 -16 +7 +8 30 T3 20 8181 8386 2 12 9.1 80 -16 +7 +8 30 T3 10 8182 8387 2 12 9.1 80 -16 +7 +8 30 T3 5 8183 8388 2 12 9.1 80 -16 +7 +8 43 T3 20 8184 8389 2 17 19.7 70 -20 +7 +8 43 T3 10 8185 8390 2 17 19.7 70 -20 +7 +8 43 T3 5 8186 8391 2 17 19.7 70 -20 +7 +8 86 T4 20 8187 8392 9 36 20.7 30 -25 +15 +15 86 T4 10 8188 8393 9 36 20.7 30 -25 +15 +15 Note (1) Style CLR65 is inactive for new military design. For new design use style CLR79. Revison: 14-Jun-16 Document Number: 40159 7 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR65 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/09FAILURE RATE LEVEL (%/1000 h) L 2.0 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/09-XXXX MAX. DF AT +25 °C (%) MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 125 VDC AT +85 °C; 85 VDC AT +125 °C 1.7 T1 20 8189 8394 1 2 7 1250 -16 +7 +8 1.7 T1 10 8190 8395 1 2 7 1250 -16 +7 +8 1.7 T1 5 8191 8396 1 2 7 1250 -16 +7 +8 3.6 T1 20 8192 8397 1 2 4.1 600 -16 +7 +8 3.6 T1 10 8193 8398 1 2 4.1 600 -16 +7 +8 3.6 T1 5 8194 8399 1 2 4.1 600 -16 +7 +8 9.0 T2 20 8195 8400 1 5 10.2 240 -16 +7 +8 9.0 T2 10 8196 8401 1 5 10.2 240 -16 +7 +8 9.0 T2 5 8197 8402 1 5 10.2 240 -16 +7 +8 25 T3 20 8204 8409 2 13 19 93 -16 +7 +8 25 T3 10 8205 8410 2 13 19 93 -16 +7 +8 25 T3 5 9026 9029 2 13 19 93 -16 +7 +8 56 T4 20 9027 9030 10 40 17.5 32 -25 +15 +15 56 T4 10 9028 9031 10 40 17.5 32 -25 +15 +15 Note (1) Style CLR65 is inactive for new military design. For new design use style CLR79. STANDARD RATINGS/EXTENDED RATINGS: CLR69 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/21FAILURE RATE LEVEL (%/1000 h) L 2.0 M 1.0 0089 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/21-XXXX MAX. DF AT +25 °C (%) MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C -64 +13 +16 6 VDC AT +85 °C; 4 VDC AT +125 °C 220 T1 20 0001 2 9 50 36 220 T1 10 0002 0090 2 9 50 36 -64 +13 +16 820 T2 20 0003 0091 3 14 155 18 -88 +16 +20 820 T2 10 0004 0092 3 14 155 18 -88 +16 +20 1500 T3 20 0005 0093 5 20 172 18 -90 +20 +25 1500 T3 10 0006 0094 5 20 172 18 -90 +20 +25 2200 T4 20 0007 0095 6 24 170 13 -90 +25 +30 2200 T4 10 0008 0096 6 24 170 13 -90 +25 +30 8 VDC AT +85 °C; 5 VDC AT +125 °C 180 T1 20 0009 0097 2 9 41 45 -60 +13 +16 180 T1 10 0010 0098 2 9 41 45 -60 +13 +16 680 T2 20 0011 0099 3 14 130 22 -83 +16 +20 680 T2 10 0012 0100 3 14 130 22 -83 +16 +20 1500 T3 20 0013 0101 5 20 170 18 -90 +20 +25 1500 T3 10 0014 0102 5 20 170 18 -90 +20 +25 1800 T4 20 0015 0103 7 25 138 14 -90 +25 +30 1800 T4 10 0016 0104 7 25 138 14 -90 +25 +30 Note (1) Style CLR69 is inactive for new military design. For new design use style CLR81. Revison: 14-Jun-16 Document Number: 40159 8 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR69 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/21FAILURE RATE LEVEL (%/1000 h) L 2.0 150 150 560 560 1200 1200 1500 1500 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0017 0018 0019 0020 0021 0022 0023 0024 100 100 390 390 820 820 1000 1000 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0025 0026 0027 0028 0029 0030 0031 0032 68 68 270 270 560 560 680 680 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0033 0034 0035 0036 0037 0038 0039 0040 56 56 220 220 470 470 560 560 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0041 0042 0043 0044 0045 0046 0047 0048 33 33 120 120 270 270 330 330 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0049 0050 0051 0052 0053 0054 0055 0056 27 27 100 100 220 220 270 270 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0057 0058 0059 0060 0061 0062 0063 0064 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/21-XXXX MAX. DF AT +25 °C (%) 10 VDC AT +85 °C; 7 VDC AT +125 °C 0105 2 9 34 0106 2 9 34 0107 3 16 106 0108 3 16 106 0109 5 20 137 0110 5 20 137 0111 7 25 114 0112 7 25 114 15 VDC AT +85 °C; 10 VDC AT +125 °C 0113 2 9 30 0114 2 9 30 0115 3 16 74 0116 3 16 74 0117 6 24 111 0118 6 24 111 0119 8 32 92 0120 8 32 92 25 VDC AT +85 °C; 15 VDC AT +125 °C 0121 2 9 22 0122 2 9 22 0123 3 16 55 0124 3 16 55 0125 7 28 76 0126 7 28 76 0127 8 32 63 0128 8 32 63 30 VDC AT +85 °C; 20 VDC AT +125 °C 0129 2 9 22 0130 2 9 22 0131 3 16 42 0132 3 16 42 0133 8 32 64 0134 8 32 64 0135 9 36 55 0136 9 36 55 50 VDC AT +85 °C; 30 VDC AT +125 °C 0137 2 9 12.3 0138 2 9 12.3 0139 4 24 22.5 0140 4 24 22.5 0141 8 32 37 0142 8 32 37 0143 9 36 38 0144 9 36 38 60 VDC AT +85 °C; 40 VDC AT +125 °C 0145 3 12 10.2 0146 3 12 10.2 0147 4 20 19 0148 4 20 19 0149 8 32 30 0150 8 32 30 0151 9 36 27 0152 9 36 27 MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 54 54 27 27 18 18 15 15 -55 -55 -77 -77 -88 -88 -88 -88 +13 +13 +16 +16 +20 +20 +25 +25 +16 +16 +20 +20 +25 +25 +30 +30 72 72 31 31 22 22 17 17 -44 -44 -66 -66 -77 -77 -77 -77 +13 +13 +16 +16 +20 +20 +25 +25 ++16 +16 +20 +20 +25 +25 +30 +30 90 90 33 33 24 24 19 19 -40 -40 -62 -62 -72 -72 -72 -72 +12 +12 +13 +13 +20 +20 +25 +25 +15 +15 +16 +16 +25 +25 +30 +30 100 100 36 36 25 25 20 20 -38 -38 -60 -60 -65 -65 -65 -65 +12 +12 +13 +13 +20 +20 +25 +25 +15 +15 +16 +16 +25 +25 +30 +30 135 135 49 49 29 29 22 22 -29 -29 -42 -42 -46 -46 -46 -46 +10 +10 +12 +12 +20 +20 +25 +25 +12 +12 +15 +15 +25 +25 +30 +30 144 144 54 54 29 29 23 23 -24 -24 -36 -36 -40 -40 -45 -45 +10 +10 +12 +12 +16 +16 +20 +20 +12 +12 +15 +15 +20 +20 +25 +25 Note Style CLR69 is inactive for new military design. For new design use style CLR81. (1) Revison: 14-Jun-16 Document Number: 40159 9 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/09, M39006/21 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR69 CAPACITANCE (μF) CASE CODE CAP. TOL. (± %) PART NO. M39006/21FAILURE RATE LEVEL (%/1000 h) L 2.0 M 1.0 (1), MAX. DCL (μA) AT +25 °C +85 °C +125 °C M39006/21-XXXX MAX. DF AT +25 °C (%) MAX. IMP. AT -55 °C () MAX. CAPACITANCE CHANGE (%) AT -55 °C +85 °C +125 °C 75 VDC AT +85 °C; 50 VDC AT +125 °C 22 T1 20 0065 0153 3 12 8.5 157 -19 +10 +12 22 T1 10 0066 0154 3 12 8.5 157 -19 +10 +12 82 T2 20 0067 0155 4 24 15.2 63 -30 +12 +15 82 T2 10 0068 0156 4 24 15.2 63 -30 +12 +15 180 T3 20 0069 0157 9 36 24.4 30 -35 +16 +20 180 T3 10 0070 0158 9 36 24.4 30 -35 +16 +20 220 T4 20 0071 0159 10 40 37 24 -40 +20 +25 220 T4 10 0072 0160 10 40 37 24 -40 +20 +25 100 VDC AT +85 °C; 65 VDC AT +125 °C 10 T1 20 0073 0161 3 12 4.5 200 -17 +10 +12 10 T1 10 0074 0162 3 12 4.5 200 -17 +10 +12 39 T2 20 0075 0163 5 24 10.4 80 -20 +12 +15 39 T2 10 0076 0164 5 24 10.4 80 -20 +12 +15 68 T3 20 0077 0165 10 40 11.3 40 -30 +14 +16 68 T3 10 0078 0166 10 40 11.3 40 -30 +14 +16 120 T4 20 0079 0167 12 48 25 30 -35 +15 +17 120 T4 10 0080 0168 12 48 25 30 -35 +15 +17 6 300 -14 +10 +12 125 VDC AT +85 °C; 85 VDC AT +125 °C 6.8 T1 20 0081 0169 3 12 6.8 T1 10 0082 0170 3 12 6 300 -14 +10 +12 27 T2 20 0083 0171 5 24 7.2 90 -18 +12 +15 27 T2 10 0084 0172 5 24 7.2 90 -18 +12 +15 47 T3 20 0085 0173 10 40 7.9 50 -26 +14 +16 47 T3 10 0086 0174 10 40 7.9 50 -26 +14 +16 82 T4 20 0087 0175 12 48 17.4 32 -30 +15 +17 82 T4 10 0088 0176 12 48 17.4 32 -30 +15 +17 Note (1) Style CLR69 is inactive for new military design. For new design use style CLR81. VOLTAGE DERATING WITH TEMPERATURE PERCENT OF RATED VOLTAGE 100 80 60 40 20 0 - 55 Revison: 14-Jun-16 - 35 -5 25 45 65 TEMPERATURE IN °C 85 105 125 Document Number: 40159 10 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000