ICPTest_BLF pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Midget Fuse
Product #:
BLF
Issue Date:
August 20, 2010
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Coordinator>
(1) Parts, sub-materials and unit parts
This document covers the GDT_Midget Fuse RoHS-Compliant series products
manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
1
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
7
Form 585-047 Rev. A
Raw Material Part Number
923-001
Fish Paper (909-410)
090190
955107
692532
648102
082xxx-001
Raw Material Description
Cap
Body
Wire-99% Cu Sn Plated
Wire-Zn Alloy
Solder
Ceramic Yarn
Element- 99% Cu Sn Plated
2
Page(s)
3-19
20-35
20-35
36-38
39-52
53-56
53-56
2/21/06
Report No.: MX10-1742
Date:2010-08-16
RESULTS REPORT
INTERTEK TESTING SERVICES
DE MEXICO SA DE CV
LABORATORIO CD. DE MEXICO
DELIVER TO:
ATTENTION:
Littelfuse, S.A. de C.V.
Blvd. Fausto Z. Martínez 1800, Col. Magisterio Sección 38,
Piedras Negras, Coahuila
Ing. Mario Falcón / Ing. Manuel Berain
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009.
Intertek Testing Services de México, S.A. de C.V.
Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec
C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863
www.intertek.com
ILTA/003/GENS-F8
Report No.: MX10-1742
Date:2010-08-16
TEST REPORT
APPLICANT
Littelfuse, S.A. de C.V.
Blvd. Fausto Z. Martínez 1800, Col. Magisterio Sección 38, Piedras Negras, Coahuila
Ing. Mario Falcón / Ing. Manuel Berain
SAMPLE DESCRIPTION
One (1) group of submitted samples said to be :
Sample Description
Serie FLQ
1) N.P. 648102
Item No.
2) N.P. 082201-001
Country of Origin
NP
Buyer's Name
NP
Supplier's Name
NP
Date sample received 2010-08-12
Testing period
2010-08-13 to 2010-08-16
********************************************************************************************
TEST CONDUCTED
As requested by the applicant, for details please refer to attached pages.
********************************************************************************************
CONCLUSION
Sample
Number
1
Testing item
Conclusion
Failed component Failed result
Pass
--See Result summary
2
Pass
N.P. 082201-001
--See Result summary
********************************************************************************************
N.P. 648102
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009.
Intertek Testing Services de México, S.A. de C.V.
Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec
C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863
www.intertek.com
ILTA/003/GENS-F8
-----
Report No.: MX10-1742
Date:2010-08-16
TEST CONDUCTED
Sample :
1)
2)
N.P. 648102
N.P. 082201-001
TEST RESULT SUMMARY FOR RoHS DIRECTIVE :
Ω RESULT (ppm)
TESTING ITEM
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
6+
Chromium (VI) (Cr )
Limit
(1)
(2)
ND
ND
0,01% (100 ppm)
13,33
ND
0,1% (1000 ppm)
ND
0,096
0,1% (1000 ppm)
ND
ND
0,1% (1000 ppm)
ppm = parts per million based on dry weight of sample.
µg/cm2 = microgram per square centimeter.
mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter.
< = less than.
ND = Not detected.
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material.
These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω.
Prepared and checked by:
For Intertek
Laboratory Manager
The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator
decimal the comma (,).
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009.
Intertek Testing Services de México, S.A. de C.V.
Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec
C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863
www.intertek.com
ILTA/003/GENS-F8
Report No.: MX10-1742
Date:2010-08-16
NOTE :DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO
ROHS DIRECTIVE AMENDMENT 2005/717/EC.
# =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF
Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE
BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS
THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE.
REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF
TESTED COMPONENTS OF THE SAMPLE MX10-1742-1 WERE TESTED TOGETHER.
REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF
TESTED COMPONENTS OF THE SAMPLE MX10-1742-2 WERE TESTED TOGETHER.
Test method:
Sample
Number
1,2
Sample
Number
Testing item
Chromium
content
VI
(Cr6+)
Testing item
Ω Testing method
Quality control
Batch:
Analysis
Date:
Analyzed
By:
Reporting limit
ppm
With reference to USEPA 3060, by
EPA 7196
QHU2009-3p168
2010-08-14
JLHS,MLG
2,0
Ω Testing method
Quality control
Batch:
Analysis
Date:
Analyzed
By:
Reporting limit
ppm
1
Lead (Pb) content
With reference to USEPA 3052, by EPA 6010
MET2010-32p50
2010-08-16
DCL,JMR
2
Lead (Pb) content
With reference to USEPA 3050-MOD, by EPA 6010
MET2010-32p51
2010-08-16
DCL,JMR
5,0
5,0
Sample
Number
Testing item
Ω Testing method
Quality control
Batch:
Analysis
Date:
Analyzed
By:
Reporting limit
ppm
1
Cadmium (Cd) content
With reference to USEPA 3052, by EPA 6010
MET2010-32p50
2010-08-16
DCL,JMR
2
Cadmium (Cd) content
With reference to USEPA 3050-MOD, by EPA 6010
MET2010-32p51
2010-08-16
DCL,JMR
2,0
2,0
Sample
Number
Testing item
Ω Testing method
Quality control
Batch:
Analysis
Date:
Analyzed
By:
Reporting limit
ppm
1
Mercury (Hg) content
With reference to USEPA 7471 by USEPA 7471
MET2010-31p37,38
2010-08-16
JAPM
2
Mercury (Hg) content
With reference to USEPA 7471 by USEPA 7471
MET2010-31p37,38
2010-08-16
JAPM
0,083
0,083
It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing
Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s).
The results that appear in this report belong solely to (s) shows (s) analyzed (s).
1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009.
Intertek Testing Services de México, S.A. de C.V.
Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec
C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863
www.intertek.com
ILTA/003/GENS-F8