ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Midget Fuse Product #: BLF Issue Date: August 20, 2010 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Coordinator> (1) Parts, sub-materials and unit parts This document covers the GDT_Midget Fuse RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: 1 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 7 Form 585-047 Rev. A Raw Material Part Number 923-001 Fish Paper (909-410) 090190 955107 692532 648102 082xxx-001 Raw Material Description Cap Body Wire-99% Cu Sn Plated Wire-Zn Alloy Solder Ceramic Yarn Element- 99% Cu Sn Plated 2 Page(s) 3-19 20-35 20-35 36-38 39-52 53-56 53-56 2/21/06 Report No.: MX10-1742 Date:2010-08-16 RESULTS REPORT INTERTEK TESTING SERVICES DE MEXICO SA DE CV LABORATORIO CD. DE MEXICO DELIVER TO: ATTENTION: Littelfuse, S.A. de C.V. Blvd. Fausto Z. Martínez 1800, Col. Magisterio Sección 38, Piedras Negras, Coahuila Ing. Mario Falcón / Ing. Manuel Berain It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s). The results that appear in this report belong solely to (s) shows (s) analyzed (s). 1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. Intertek Testing Services de México, S.A. de C.V. Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863 www.intertek.com ILTA/003/GENS-F8 Report No.: MX10-1742 Date:2010-08-16 TEST REPORT APPLICANT Littelfuse, S.A. de C.V. Blvd. Fausto Z. Martínez 1800, Col. Magisterio Sección 38, Piedras Negras, Coahuila Ing. Mario Falcón / Ing. Manuel Berain SAMPLE DESCRIPTION One (1) group of submitted samples said to be : Sample Description Serie FLQ 1) N.P. 648102 Item No. 2) N.P. 082201-001 Country of Origin NP Buyer's Name NP Supplier's Name NP Date sample received 2010-08-12 Testing period 2010-08-13 to 2010-08-16 ******************************************************************************************** TEST CONDUCTED As requested by the applicant, for details please refer to attached pages. ******************************************************************************************** CONCLUSION Sample Number 1 Testing item Conclusion Failed component Failed result Pass --See Result summary 2 Pass N.P. 082201-001 --See Result summary ******************************************************************************************** N.P. 648102 It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s). The results that appear in this report belong solely to (s) shows (s) analyzed (s). 1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. Intertek Testing Services de México, S.A. de C.V. Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863 www.intertek.com ILTA/003/GENS-F8 ----- Report No.: MX10-1742 Date:2010-08-16 TEST CONDUCTED Sample : 1) 2) N.P. 648102 N.P. 082201-001 TEST RESULT SUMMARY FOR RoHS DIRECTIVE : Ω RESULT (ppm) TESTING ITEM Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) Limit (1) (2) ND ND 0,01% (100 ppm) 13,33 ND 0,1% (1000 ppm) ND 0,096 0,1% (1000 ppm) ND ND 0,1% (1000 ppm) ppm = parts per million based on dry weight of sample. µg/cm2 = microgram per square centimeter. mg/kg WITH 50cm2 = milligram per kilogram with 50 square centimeter. < = less than. ND = Not detected. The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. These Accreditations only apply for the methods listed in such. Not accredited under EMA Ω. Prepared and checked by: For Intertek Laboratory Manager The Official Mexican Standard NOM-008-SCFI-1993 establishes like separator decimal the comma (,). It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s). The results that appear in this report belong solely to (s) shows (s) analyzed (s). 1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. Intertek Testing Services de México, S.A. de C.V. Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863 www.intertek.com ILTA/003/GENS-F8 Report No.: MX10-1742 Date:2010-08-16 NOTE :DecaBDE IN POLYMERIC APPLICATIONS IS EXEMPTED ACCORDING TO ROHS DIRECTIVE AMENDMENT 2005/717/EC. # =ACCORDING TO IEC 62321, A POSITIVE RESULT INDICATES THE PRESENCE OF Cr(VI) COATING. IT IS THE Cr(VI) CONCENTRATION DETECTED IN THE BOILING-WATER-EXTRACTION SOLUTION AND SHOULD NOT BE INTERPRETED AS THE Cr(VI) CONCENTRATION IN THE COATING LAYER OF THE SAMPLE. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX10-1742-1 WERE TESTED TOGETHER. REMARK : AS REQUESTED BY THE APPLICANT, COATING WITH BASE MATERIAL OF TESTED COMPONENTS OF THE SAMPLE MX10-1742-2 WERE TESTED TOGETHER. Test method: Sample Number 1,2 Sample Number Testing item Chromium content VI (Cr6+) Testing item Ω Testing method Quality control Batch: Analysis Date: Analyzed By: Reporting limit ppm With reference to USEPA 3060, by EPA 7196 QHU2009-3p168 2010-08-14 JLHS,MLG 2,0 Ω Testing method Quality control Batch: Analysis Date: Analyzed By: Reporting limit ppm 1 Lead (Pb) content With reference to USEPA 3052, by EPA 6010 MET2010-32p50 2010-08-16 DCL,JMR 2 Lead (Pb) content With reference to USEPA 3050-MOD, by EPA 6010 MET2010-32p51 2010-08-16 DCL,JMR 5,0 5,0 Sample Number Testing item Ω Testing method Quality control Batch: Analysis Date: Analyzed By: Reporting limit ppm 1 Cadmium (Cd) content With reference to USEPA 3052, by EPA 6010 MET2010-32p50 2010-08-16 DCL,JMR 2 Cadmium (Cd) content With reference to USEPA 3050-MOD, by EPA 6010 MET2010-32p51 2010-08-16 DCL,JMR 2,0 2,0 Sample Number Testing item Ω Testing method Quality control Batch: Analysis Date: Analyzed By: Reporting limit ppm 1 Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-31p37,38 2010-08-16 JAPM 2 Mercury (Hg) content With reference to USEPA 7471 by USEPA 7471 MET2010-31p37,38 2010-08-16 JAPM 0,083 0,083 It is prohibited the total or partial reproduction of this document, as well as any modification or alteration in no of its parts without the previous authorization of Intertek Testing Services de México, S.A. de C.V. On the contrary Intertek reserves the right of coming from legal form against that (it is) they are responsible (s). The results that appear in this report belong solely to (s) shows (s) analyzed (s). 1ª. Emisión Junio 2005, 1° Revisión Junio 26, 2009. Intertek Testing Services de México, S.A. de C.V. Blvd. Manuel Ávila Camacho No. 182 Col. Lomas de Chapultepec C.P. 11650, México, D.F. Tel.: 50912150 Fax: 55407863 www.intertek.com ILTA/003/GENS-F8