INTERSIL ISL23511

ISL23511
®
Single Push Button Controlled Potentiometer (XDCP™)
Data Sheet
December 3, 2007
Low Noise, Low Power, 32 Taps, Push
Button Controlled Potentiometer
Features
• Solid-state volatile potentiometer
The Intersil ISL23511 is a three-terminal digitally-controlled
potentiometer (XDCP) implemented by a resistor array
composed of 31 resistive elements and a wiper switching
network. The ISL23511 features a push button control, a
shutdown mode, as well as an industry-leading µTQFN
package.
• Push button controlled
• Single or Auto increment/decrement
- Fast Mode after 1s button press
• Shutdown Mode
The push button control has individual PU and PD inputs for
adjusting the wiper. To eliminate redundancy the wiper
position will automatically increment or decrement if one of
these inputs is held longer than one second.
Forcing both PU and PD low for more than two seconds
activates shutdown mode. Shutdown mode disconnects the
top of the resistor chain and moves the wiper to the lowest
position, minimizing power consumption.
The three terminals accessing the resistor chain naturally
configure the ISL23511 as a voltage divider. A rheostat is
easily formed by floating an end terminal or connecting it to
the wiper.
VCC (SUPPLY VOLTAGE)
RH
PD
2
RH
3
VSS
4
PD
CONTROL
BLOCK
• Low power CMOS
- VCC = 2.7V to 5.5V
- Terminal voltage, 0 to VCC
- Standby current, 3µA max
• RTOTAL value = 10kΩ, 50kΩ
• Packages
- 8 Ld SOIC and 10 Ld µTQFN (2.1x1.6mm)
Applications
• Volume Control
10
9
NC
uTFQFN
8
VCC
(Top View)
7
NC
6
RL
• LED/LCD Brightness Control
• Contrast Control
• Programming Bias Voltages
5
PU
1
• 32 wiper tap points
- Zero scale wiper position on power-up
• Pb-free (RoHS compliant)
NC
O
PU
FN6588.0
RW
RW
• Ladder Networks
O
RL
PU
1
8
VCC
PD
2
SOIC
7
NC
RH
3
(Top View)
6
RL
VSS
4
5
RW
VSS (GROUND)
Ordering Information
PART
NUMBER
PART
MARKING
RTOTAL
(kΩ)
TEMP.
RANGE(°C)
PACKAGE
(Pb-Free)
PKG.
DWG. #
ISL23511WFB8Z* (Note 1)
23511 WFBZ
10
-40 to +125
8 Ld SOIC
M8.15
ISL23511UFB8Z* (Note 1)
23511 UFBZ
50
-40 to +125
8 Ld SOIC
M8.15
ISL23511WFRU10Z* (Note 2)
GA
10
-40 to +125
10 Ld µTQFN
L10.2.1x1.6A
ISL23511UFRU10Z* (Note 2)
FZ
50
-40 to +125
10 Ld µTQFN
L10.2.1x1.6A
*Add “-TK” suffix for tape and reel. Please refer to TB347 for details on reel specifications.
NOTES:
1. These Intersil Pb-free plastic packaged products employ special Pb-free material sets; molding compounds/die attach materials and 100%
matte tin plate PLUS ANNEAL - e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering
operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of
IPC/JEDEC J STD-020.
2. These Intersil Pb-free plastic packaged products employ special Pb-free material sets; molding compounds/die attach materials and NiPdAu
plate - e4 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free
products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020.
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
XDCP is a trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2007. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
ISL23511
Pinouts
ISL23511
(10 LD µTDFN)
TOP VIEW
ISL23511
(8 LD SOIC)
TOP VIEW
1
8
VCC
PD
2
7
NC
RH
3
6
RL
VSS
4
5
RW
PU
1
9
NC
PD
2
8
VCC
RH
3
7
NC
VSS
4
6
RL
5
PU
O
10
NC
O
RW
Pin Descriptions
SOIC
PIN
µTQFN
PIN
SYMBOL
1
1
PU
The PU is a negative-edge triggered input with internal pull-up. Toggling PU will move the wiper close to RH
terminal.
2
2
PD
The PD is a negative-edge triggered input with internal pull-up. Toggling PD will move the wiper close to RL
terminal.
3
3
RH
The RH and RL pins of the ISL23511 are equivalent to the fixed terminals of a mechanical potentiometer. The
minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position
of the terminal in relation to wiper movement direction selected by the PU/PD input.
4
4
VSS
Ground
5
5
RW
The RW pin is the wiper terminal of the potentiometer which is equivalent to the movable terminal of a mechanical
potentiometer.
6
6
RL
The RH and RL pins of the ISL23511 are equivalent to the fixed terminals of a mechanical potentiometer. The
minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position
of the terminal in relation to wiper movement direction selected by the PU/PD input.
7
7, 9, 10
NC
No connection
8
8
VCC
Supply Voltage
BRIEF DESCRIPTION
Block Diagrams
PU
PD
VCC (SUPPLY VOLTAGE)
5-BIT
UP/DOWN
COUNTER
RH
31
30
29
RH
PU
PD
CONTROL
BLOCK
RW
ONE 28
OF
THIRTY
TWO
DECODER
TRANSFER
GATES
RESISTOR
ARRAY
RW
2
RL
1
0
VSS (GROUND)
GENERAL
RL
DETAILED
2
FN6588.0
December 3, 2007
ISL23511
Absolute Maximum Ratings
Thermal Information
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage at PU and PD Pin with Respect to GND . -0.3V to VCC + 0.3
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +6V
Voltage at any DCP Pin with respect to GND . . . . . . . . -0.3V to VCC
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Latchup . . . . . . . . . . . . . . . . . . . . . . . . . Class II, Level A @ +125°C
ESD Rating
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3kV
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250V
Thermal Resistance (Typical, Note 3, 4)
θJA (°C/W)
θJC (°C/W)
8 Lead SOIC . . . . . . . . . . . . . . . . . . . .
120
10 Lead µTQFN . . . . . . . . . . . . . . . . .
150
48.3
Maximum Junction Temperature (Plastic Package). . . . . . . . +150°C
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Temperature Range (Extended Industrial). . . . . . . .-40°C to +125°C
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Power Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15mW
Wiper Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3.0mA
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
3. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
4. θJC is for the location in the center of the exposed metal pad on the package underside.
Potentiometer Specifications Over recommended operating conditions, unless otherwise specified.
SYMBOL
RTOTAL
PARAMETER
RH to RL Resistance
TEST CONDITIONS
MIN
(Note 18)
W option
kΩ
+20
%
End-to-End Temperature Coefficient W option
±80
ppm/°C
(Note 16)
U option
±125
ppm/°C
(Note 16)
Wiper Resistance
VCC = 3.3V, wiper current IRW = VCC/RTOTAL
VRH and VRL Terminal Voltages
VRH and VRL to GND
Noise on wiper terminal
from 0Hz to 10MHz
CH/CL/CW
(Note 17)
Potentiometer Capacitance
ILkgDCP
UNIT
kΩ
50
-20
VRH, VRL
RW
MAX
(Note 18)
10
U option
RH to RL Resistance Tolerance
TYP
(Note 5)
Leakage on DCP Pins
130
0
Voltage at pin from GND to VCC
400
Ω
VCC
V
-80
dBV
10/10/25
pF
0.05
0.4
µA
-1
1
LSB
(Note 6)
-0.5
0.5
LSB
(Note 6)
0.3
3
LSB
(Note 6)
VOLTAGE DIVIDER MODE (0V @ RL; VCC @ RH; measured at RW unloaded)
INL
(Note 10)
Integral Non-linearity
DNL
(Note 9)
Differential Non-linearity
Monotonic over all tap positions
ZSerror
(Note 7)
Zero-scale Error
W option
FSerror
(Note 8)
Full-scale Error
TCV
(Note 11)
fCUTOFF
0
U option
0
0.3
1
W option
-3
-0.3
0
U option
-1
-0.3
0
LSB
(Note 6)
Ratiometric Temperature Coefficient wiper from 5 hex to 1F hex for W and U option
±25
ppm/°C
3dB cut off frequency
wiper at the middle scale, W option
500
kHz
wiper at the middle scale, U option
75
kHz
RESISTOR MODE (Measurements between RW and RL with RH not connected, or between RW and RH with RL not connected)
RINL
(Note 15)
Integral Non-linearity
3
DCP register set between 1 hex and 1F hex;
monotonic over all tap positions; W option
-1.5
1.5
MI
(Note 12)
DCP register set between 1 hex and 1F hex;
monotonic over all tap positions; U option
-1
1
MI
(Note 12)
FN6588.0
December 3, 2007
ISL23511
Potentiometer Specifications Over recommended operating conditions, unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 18)
RDNL
(Note 14)
Differential Non-linearity
W and U option
Roffset
(Note 13)
Offset
W option
0
U option
0
DC Electrical Specifications
SYMBOL
PARAMETER
VCC Active Current
ISB
Standby Current
ILkg
PU, PD Input Leakage Current
VIH
PU, PD Input HIGH Voltage
-0.5
MI
(Note 12)
1
3
MI
(Note 12)
0.5
1
MI
(Note 12)
TEST CONDITIONS
MIN
(Note 18)
TYP
(Note 5)
MAX
(Note 18)
UNIT
150
µA
3
µA
+2
µA
0.6
VIL
PU, PD input LOW Voltage
PU, PD Input Capacitance
Rpull_up
(Note 17)
Pull-up Resistor for PU and PD
AC Electrical Specifications
SYMBOL
UNIT
0.5
VCC = 5.5V, perform wiper move
operation
CIN
(Note 17)
tDB
MAX
(Note 18)
Over recommended operating conditions unless otherwise specified.
ICC
tGAP
(Note 17)
TYP
(Note 5)
VIN = VSS to VCC
-2
VCC x 0.7
V
VCC x 0.1
VCC = 3.3V, TA = +25°C, f = 1MHz
V
10
pF
1
MΩ
Over recommended operating conditions unless otherwise specified.
PARAMETER
MIN
(Note 18)
TYP
(Note 5)
MAX
(Note 18)
UNIT
Time Between Two Separate Push Button Events
1
ms
Debounce Time
15
30
ms
tS SLOW
Wiper Change on a Slow Mode
100
250
375
ms
tS FAST
Wiper Change on a Fast Mode
25
50
75
ms
tstdn
(Note 17)
tR VCC
Time to Enter Shutdown Mode (keep PU and PD LOW)
VCC Power-up Rate
2
0.2
s
50
V/ms
NOTES:
5. Typical values are for TA = +25°C and 3.3V supply voltage.
6. LSB: [V(RW)31 – V(RW)0]/31. V(RW)31 and V(RW)0 are voltage on RW pin for the DCP register set to 1F hex and 00 hex respectively. LSB is
the incremental voltage when changing from one tap to an adjacent tap.
7. ZS error = V(RW)0/LSB.
8. FS error = [V(RW)31 – VCC]/LSB.
9. DNL = [V(RW)i – V(RW)i-1]/LSB -1, for i = 1 to 31; i is the DCP register setting.
10. INL = [V(RW)i – i • LSB – V(RW)]/LSB for i = 1 to 31
Max ( V ( RW ) i ) – Min ( V ( RW ) i )
10 6
11. TC = --------------------------------------------------------------------------------------------- × ---------------------for i = 5 to 31 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
V
[ Max ( V ( RW ) i ) + Min ( V ( RW ) i ) ] ⁄ 2 +165°C voltage and Min ( ) is the minimum value of the wiper voltage over the temperature range.
12. MI = |RW31 – RW0|/31. MI is a minimum increment. RW31 and RW0 are the measured resistances for the DCP register set to 1F hex and 00
hex respectively.
13. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW31/MI, when measuring between RW and RH.
14. RDNL = (RWi – RWi-1)/MI, for i = 1 to 31.
15. RINL = [RWi – (MI • i) – RW0]/MI, for i = 1 to 31.
6 for i = 5 to 31, T = -40°C to +125°C. Max( ) is the maximum value of the resistance and Min ( ) is the
[ Max ( Ri ) – Min ( Ri ) ]
10
TC R = ---------------------------------------------------------------- × --------------------- minimum value of the resistance over the temperature range.
[ Max ( Ri ) + Min ( Ri ) ] ⁄ 2 +165°C
17. Limits should be considered typical and are not production tested.
16.
18. Parts are 100% tested at +25°C. Over-temperature limits established by characterization and are not production tested.
4
FN6588.0
December 3, 2007
ISL23511
Slow Mode Timing
tDB
tGAP
PU
MI*
VW
* MI in the AC timing diagram refers to the minimum incremental change in the wiper voltage.
Fast Mode Timing
tDB
PU
tS FAST
tS SLOW
MI*
VW
1s
* MI in the AC timing diagram refers to the minimum incremental change in the wiper voltage.
Shutdown Mode Timing
tDB
2s
SHUTDOWN MODE
PU
PD
VW
5
FN6588.0
December 3, 2007
ISL23511
Typical Performance Curves
160
3.0
VCC = 5.5V
+125ºC
2.5
120
2.0
+25ºC
100
ICC (µA)
WIPER RESISTANCE (Ω)
140
80
60
VCC = 5.5V
VCC = 2.7V
1.0
-40ºC
40
0.5
20
0
1.5
0
5
10
15
20
25
0
-40
30
-15
10
TAP POSITION (DECIMAL)
35
60
85
110
TEMPERATURE (°C)
FIGURE 1. WIPER RESISTANCE vs TAP POSITION
[ I(RW) = VCC/RTOTAL ] FOR 10kΩ (W)
FIGURE 2. STANDBY ICC vs TEMPERATURE
0.03
0.010
VCC = 2.7V
VCC = 2.7V
0.02
0.005
INL (LSB)
DNL (LSB)
0.01
0.000
0.00
-0.01
-0.005
VCC = 5.5V
-0.02
VCC = 5.5V
-0.010
0
5
10
15
20
25
-0.03
30
0
5
TAP POSITION (DECIMAL)
FIGURE 3. DNL vs TAP POSITION IN VOLTAGE DIVIDER
MODE FOR 10kΩ (W)
20
25
30
0
0.005
0.004
VCC = 5.5V
0.003
0.002
VCC = 2.7V
0.001
-15
10
35
60
85
TEMPERATURE (°C)
FIGURE 5. ZS ERROR vs TEMPERATURE
6
110
FULL SCALE ERROR (LSB)
ZERO SCALE ERROR (LSB)
15
FIGURE 4. INL vs TAP POSITION IN VOLTAGE DIVIDER
MODE FOR 10kΩ (W)
0.006
0
-40
10
TAP POSITION (DECIMAL)
VCC = 5.5V
-0.1
-0.2
-0.3
-0.4
VCC = 2.7V
-0.5
-40
-15
10
35
60
85
110
TEMPERATURE (°C)
FIGURE 6. FS ERROR vs TEMPERATURE
FN6588.0
December 3, 2007
ISL23511
Typical Performance Curves
(Continued)
0.2
0.8
VCC = 2.7V
VCC = 2.7V
0.6
RINL (LSB)
RDNL (LSB)
0.1
0.0
-0.1
-0.2
5
10
VCC = 5.5V
0.2
VCC = 5.5V
0
0.4
15
20
25
0.0
30
0
5
TAP POSITION (DECIMAL)
15
20
25
FIGURE 8. INL vs TAP POSITION IN RHEOSTAT MODE FOR
10kΩ (W)
40
1.20
10k
35
VCC = 5.5V
30
TCv (ppm/°C)
0.60
10k
0.00
VCC = 2.7V
-0.60
-1.20
-40
25
VCC = 5.5V
15
50k
5
0
-15
VCC = 2.7V
20
10
50k
10
35
60
85
110
5
10
15
20
25
FIGURE 10. TC FOR VOLTAGE DIVIDER MODE IN ppm
FIGURE 9. END TO END RTOTAL % CHANGE vs
TEMPERATURE
300
250
TCr (ppm/°C)
50k
200
VCC = 5.5V
150
10k
100
0
VCC = 2.7V
5
10
15
20
30
TAP POSITION (DECIMAL)
TEMPERATURE (°C)
50
30
TAP POSITION (DECIMAL)
FIGURE 7. DNL vs TAP POSITION IN RHEOSTAT MODE FOR
10kΩ (W)
RTOTAL CHANGE (%)
10
25
30
TAP POSITION (DECIMAL)
FIGURE 11. TC FOR RHEOSTAT MODE IN ppm
FIGURE 12. FREQUENCY RESPONSE (500kHz)
ISL23511
Power-Up and Power-Down Requirements
There are no restrictions on the power-up or power-down
conditions of VCC and the voltages applied to the
potentiometer pins provided that VCC is always more
positive than or equal to VRH and VRL, i.e., VCC ≥ VRH,VRL.
The VCC ramp rate specification is always in effect.
Pin Descriptions
RH and RL
The RH and RL pins of the ISL23511 are equivalent to the
fixed terminals of a mechanical potentiometer. The minimum
voltage is VSS and the maximum is VCC. The terminology of
RH and RL references the relative position of the terminal in
relation to wiper movement direction.
RW
The RW pin is the wiper terminal of the potentiometer which
is equivalent to the movable terminal of a mechanical
potentiometer. The default wiper position at power-up is at
0 tap.
PU
The debounced PU input is used to increment the wiper
position. An on-chip pull-up holds the PU input HIGH. A
switch closure to ground or a LOW logic level will, after a
debounce time, move the wiper to the next adjacent higher
tap position.
PD
input, the wiper will be switched to the next adjacent tap
position.
Internal debounce circuitry prevents inadvertent switching of
the wiper position if PU or PD remain LOW for less than
15ms, typical. Each of the buttons can be pushed either
once for a single increment/decrement or continuously for a
multiple increments/decrements. The number of
increments/decrements of the wiper position depend on how
long the button is being pushed. When making a continuous
push, after the first second, the increment/decrement speed
increases. For the first second, the device will be in the slow
scan mode. Then, if the button is held for longer than 1s, the
device will go into the fast scan mode. As soon as the button
is released, the ISL23511 will return to a stand-by condition.
If both PU and PD buttons are pulled low more than 15ms
from each other, all commands are ignored upon release of
ALL buttons.
The wiper, when at either fixed terminal, acts like its
mechanical equivalent and does not move beyond the last
position. That is, the counter does not wrap around when
clocked to either extreme.
Shutdown Mode
The ISL23511 enters into Shutdown Mode if both PU and PD
inputs are kept LOW for 2 seconds. In this mode, the
resistors array is totally disconnected from its RH pin and the
wiper is moved to the position closest to the RL pin, as
shown in Figure 13.
RH
The debounced PD input is used to decrement the wiper
position. An on-chip pull-up holds the PD input HIGH. A
switch closure to ground or a LOW logic level will, after a
debounce time, move the wiper to the next adjacent lower
tap position.
RW
Device Operation
RL
There are three sections of the ISL23511: the input control,
the counter and decode section and the resistor array. The
input control section operates just like an up/down counter.
The output of this counter is decoded to turn on a single
electronic switch, connecting a point on the resistor array to
the wiper output. The resistor array is comprised of 31
individual resistors connected in series. At either end of the
array and between each resistor is an electronic switch that
transfers the potential at that point to the wiper.
The ISL23511 is designed to interface directly to two push
button switches for effectively moving the wiper up or down.
The PU and PD inputs increment or decrement a 5-bit
counter respectively. The output of this counter is decoded to
select one of the thirty-two wiper positions along the resistive
array. The wiper increment input, PU and the wiper
decrement input, PD are both connected to an internal
pull-up so that they normally remain HIGH. When pulled
LOW by an external push button switch or a logic LOW level
8
FIGURE 13. DCP CONNECTION IN SHUTDOWN MODE
Note that PU and PD inputs must be brought LOW within tDB
time window of 15ms (see “Shutdown Mode Timing” on
page 5.) otherwise all commands will be ignored until both
inputs are released.
Holding either PU or PD input LOW for more than 15ms will
exit shutdown mode and return wiper to prior shutdown
position. If PU or PD will be held LOW for more than 250ms,
the ISL23511 will start auto-increment or auto-decrement of
wiper position.
RTOTAL with VCC Removed
The end to end resistance of the array will fluctuate once
VCC is removed.
FN6588.0
December 3, 2007
ISL23511
9
FN6588.0
December 3, 2007
ISL23511
Ultra Thin Quad Flat No-Lead Plastic Package (UTQFN)
D
6
INDEX AREA
A
L10.2.1x1.6A
B
N
10 LEAD ULTRA THIN QUAD FLAT NO-LEAD PLASTIC
PACKAGE
MILLIMETERS
E
SYMBOL
2X
MIN
NOMINAL
MAX
1
2X
2
0.10 C
TOP VIEW
C
A
0.05 C
SEATING PLANE
1
0.45
0.50
0.55
-
A1
-
-
0.05
-
0.127 REF
-
b
0.15
0.20
0.25
5
D
2.05
2.10
2.15
-
E
1.55
1.60
1.65
-
A1
e
SIDE VIEW
k
0.20
-
-
L
0.35
0.40
0.45
(DATUM A)
PIN #1 ID
A
A3
0.10 C
4xk
2
NX L
0.50 BSC
-
NX b
e
2
Nd
4
3
Ne
1
3
0
-
12
NOTES:
5
BOTTOM VIEW
CL
(A1)
L
5
e
SECTION "C-C"
TERMINAL TIP
C C
4
Rev. 3 6/06
0.10 M C A B
0.05 M C
3
(ND-1) X e
-
10
(DATUM B)
N-1
-
N
θ
N
NX (b)
NOTES
0.10 C
FOR ODD TERMINAL/SIDE
b
1. Dimensioning and tolerancing conform to ASME Y14.5-1994.
2. N is the number of terminals.
3. Nd and Ne refer to the number of terminals on D and E side,
respectively.
4. All dimensions are in millimeters. Angles are in degrees.
5. Dimension b applies to the metallized terminal and is measured
between 0.15mm and 0.30mm from the terminal tip.
6. The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 identifier may be
either a mold or mark feature.
7. Maximum package warpage is 0.05mm.
8. Maximum allowable burrs is 0.076mm in all directions.
9. Same as JEDEC MO-255UABD except:
No lead-pull-back, "A" MIN dimension = 0.45 not 0.50mm
"L" MAX dimension = 0.45 not 0.42mm.
10. For additional information, to assist with the PCB Land Pattern
Design effort, see Intersil Technical Brief TB389.
2.50
1.75
0.05 MIN
L
2.00
0.80
0.275
0.10 MIN
DETAIL “A” PIN 1 ID
0.50
0.25
LAND PATTERN 10
10
FN6588.0
December 3, 2007
ISL23511
Small Outline Plastic Packages (SOIC)
M8.15 (JEDEC MS-012-AA ISSUE C)
N
8 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE
INDEX
AREA
H
0.25(0.010) M
B M
INCHES
E
SYMBOL
-B-
1
2
3
L
SEATING PLANE
-A-
A
D
h x 45°
-C-
e
A1
B
0.25(0.010) M
C
0.10(0.004)
C A M
MIN
MAX
MIN
MAX
NOTES
A
0.0532
0.0688
1.35
1.75
-
A1
0.0040
0.0098
0.10
0.25
-
B
0.013
0.020
0.33
0.51
9
C
0.0075
0.0098
0.19
0.25
-
D
0.1890
0.1968
4.80
5.00
3
E
0.1497
0.1574
3.80
4.00
4
e
α
B S
0.050 BSC
1.27 BSC
-
H
0.2284
0.2440
5.80
6.20
-
h
0.0099
0.0196
0.25
0.50
5
L
0.016
0.050
0.40
1.27
6
N
α
NOTES:
MILLIMETERS
8
0°
8
8°
0°
7
8°
1. Symbols are defined in the “MO Series Symbol List” in Section 2.2 of
Publication Number 95.
Rev. 1 6/05
2. Dimensioning and tolerancing per ANSI Y14.5M-1982.
3. Dimension “D” does not include mold flash, protrusions or gate burrs.
Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006
inch) per side.
4. Dimension “E” does not include interlead flash or protrusions. Interlead flash and protrusions shall not exceed 0.25mm (0.010 inch) per
side.
5. The chamfer on the body is optional. If it is not present, a visual index
feature must be located within the crosshatched area.
6. “L” is the length of terminal for soldering to a substrate.
7. “N” is the number of terminal positions.
8. Terminal numbers are shown for reference only.
9. The lead width “B”, as measured 0.36mm (0.014 inch) or greater
above the seating plane, shall not exceed a maximum value of
0.61mm (0.024 inch).
10. Controlling dimension: MILLIMETER. Converted inch dimensions
are not necessarily exact.
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
11
FN6588.0
December 3, 2007