DATASHEET K2 ULTRACAPACITORS - 3.0V/3000F FEATURES AND BENEFITS TYPICAL APPLICATIONS Highest voltage and power DuraBlueTM Shock and Vibration Technology Up to 1,000,000 duty cycles or 10 year DC life* 16 kW/kg of Specific Power 3.75 Wh of Stored Energy High shock and vibration environments Automotive subsystems Wind turbine pitch control Hybrid vehicles Rail Heavy industrial equipment UPS & telecom systems PRODUCT SPECIFICATIONS ELECTRICAL NEW TYPICAL CHARACTERISTICS BCAP3000 TEMPERATURE BCAP3000 Rated Voltage 3.00 V Operating temperature range Minimum Capacitance1, initial, rated value 3,000 F (Cell case temperature) Maximum ESR DC 1, initial, rated value 0.27 mΩ Minimum -40oC Maximum 65oC POWER & ENERGY Usable Specific Power, Pd2 7.7 kW/kg ELECTRICAL Impedance Match Specific Power, Pmax3 16 kW/kg Leakage Current at 25°C, maximum7 12 mA Specific Energy, Emax 7.2 Wh/kg Absolute Maximum Voltage 8 3.25 V 3.75 Wh Absolute Maximum Current 2,200 A 4 Stored Energy, E stored5 LIFE SHOCK & VIBRATION Vibration Specification Shock Specification ISO 16750-3, Tables 12 & 14 SAE J2464, IEC 60068-2-27, -29 SAFETY Short Circuit Current, typical (Current possible with short circuit from rated voltage. Do not use as an operating current.) Certifications DC Life at High Temperature1 (held continuously at Rated Voltage & Maximum Operating Temperature) Capacitance Change (% decrease from rated value) ESR Change 11,000 A RoHS, REACH THERMAL (% increase from rated value) Projected DC Life at 25°C1 (held continuously at Rated Voltage) Capacitance Change (% decrease from rated value) Thermal Resistance (Rca, Case to Ambient), typical 3.2oC/W Thermal Capacitance (Cth), typical 600 J/oC Maximum Continuous Current (ΔT = 15°C)6 130 ARMS Maximum Continuous Current (ΔT = 40°C)6 210 ARMS ESR Change (% increase from rated value) Projected Cycle Life at 25°C1, 9, 10 Capacitance Change (% decrease from rated value) ESR Change (% increase from rated value) Shelf Life (Stored uncharged at 25±10°C) 1,500 hours 20% 100% 10 years 20% 100% 1,000,000 cycles 20% 100% 4 years PHYSICAL Mass, typical Threads *Results may vary. Additional terms and conditions, including the limited warranty, apply at the time of purchase. See the warranty details for applicable operating and use requirements. Page 1 Document number: 3001423-EN.1 maxwell.com 520 g M12 X 1.7511 DATASHEET K2 ULTRACAPACITORS - 3.0V/3000F BCAP3000 P300 K04 NOTES 1. 2. Part Description Dimensions (mm) L (±0.3mm) D1 (±0.2mm) D2 (±0.7mm) Package Quantity 138 60.4 60.7 15 BCAP3000 P300 K04 NEW MOUNTING RECOMMENDATIONS Capacitance and ESRDC measured using 100 A test current at 25°C per document number 1007239 available at maxwell.com. 0.12V2 Per IEC 62391-2, Pd = ESRDC x mass 3. Pmax = V2 4 x ESRDC x mass 4. Emax = ½ CV2 3,600 x mass 5. Estored = 6. ∆T=IRMS2 x ESR x Rca ½ CV2 3,600 7. 8. 9. After 72 hours at rated voltage. Initial leakage current can be higher. Absolute maximum voltage, non-repeated. Not to exceed 1 second. Cycle between 3.0V and 1.5V using 100 A constant current with 5 second rest at 3.0V and 15 second rest at 1.5V. 10. Cycle life varies depending upon application-specific characteristics. Actual results will vary. 11. Maximum Torque is 14 Nm. MARKINGS Do not reverse polarity. Products are marked with the following information: Rated capacitance, rated voltage, product number, name of manufacturer, positive terminal, warning marking, serial number. Product dimensions are for reference only unless otherwise identified. Product dimensions and specifications may change without notice. Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this datasheet are covered by the following U.S. patents and their respective foreign counterparts: 6643119, 7295423, 7342770, 7352558, 7384433, 7440258, 7492571, 7508651, 7580243, 7791860, 7791861, 7859826, 7883553, 7935155, 8072734, 8098481, 8279580. Maxwell Technologies, Inc. Global Headquarters 3888 Calle Fortunada San Diego, CA 92123 USA Tel: +1 (858) 503-3300 Fax: +1 (858) 503-3301 Maxwell Technologies SA Route de Montena 65 CH-1 728 Rossens Switzerland Tel: +41 (0)26 411 85 00 Fax: +41 (0)26 411 85 05 Maxwell Technologies, GmbH Leopoldstrasse 244 80807 Münich Germany Tel: +49 (0)89 / 4161403 0 Fax: +49 (0)89 / 4161403 99 Maxwell Technologies, Inc. Shanghai Trading Co. Ltd Unit A2BC, 12th Floor Huarun Times Square 500 Zhangyang Road, Pudong Shanghai, 200122, P.R. China Phone: +86 21 3852 4000 Fax: +86 21 3852 4099 Maxwell Technologies Korea Co., Ltd Room 1524, D-Cube City Office Tower, 15F #662 Gyeongin-Ro, Guro-Gu, Seoul, Korea, 152-706 Phone: +82 10 4518 9829 MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGY’S FUTURE, BOOSTCAP, D CELL and their respective designs and/or logos are either trademarks or registered trademarks of Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in part, without the prior written permission from Maxwell Technologies, Inc. All contents copyright © 2016 Maxwell Technologies, Inc. All rights reserved. No portion of these materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc. Page 2 Document number: 3001423-EN.1 maxwell.com