PS_PS-DA0412-300.pdf

DC-AC INVERTER UNIT
PS-DA0412-300(S) (25 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for quad lamps.
Optimized for AUO: M190EG01 V0
APPLICABLE LCD:
15 to 21 inches quad lamps
Lamp Voltage 653 Vrms
Lamp Current 4 x 7.5 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open lamp detection
Internal PWM controller with wide dimming range
High efficiency
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +50°C
-30°C ~ +85°C
95 %RH max
200 x 44 x 12 mm
PS-DA0412-05(S)
Unit : mm
Weight :38,4 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 ~ CN5
Input side CN1:
Pin No. Symbols
Vin
CN 1-1;2;3
GND
CN 1-4;5;6
Vbr
CN 1-7
Vrmt
CN 1-8
Qty.
1
1
4
Material
UL94V-0 (FR-4 or CEM-3)
B8B-PH-K
SM02B-BHSS-1-TB
Note
t=1mm
JST or equal
JST or equal
Output side CN2 ~ CN5
Pin No.
CN 2-1
CN 2-2
Ratings
10.8 ~ 13.2 Vdc
Symbols
Vhigh
Vlow
Ratings
653 Vrms (7.5 mArms)
(GND)
0 ~ 3.0 Vdc
0 ~ 0.5 = OFF / 3.3 ~ Vin = ON
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1, 20th May 2014
DC-AC INVERTER UNIT
PS-DA0412-300(S) (25 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1:
Note 2:
Vin (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
Conditions
Vrmt
Tu (°C)
(V)
5±0.25 0 ~ +50
5±0.25 0 ~ +50
5±0.25 0 ~ +50
5±0.25 0 ~ +50
5±0.25 0 ~ +50
Specification
Min.
Typ.
Max.
7.0
7.5
20
2.5
55
1.800
8.0
3.2
60
3.000
50
1.650
Unit
mArms
%
Adc
kHz
Vrms
Note
Vbr = 0 Vdc
Vbr = 3.0 Vdc
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany