DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0412-06(S) (25 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for quad lamps.
APPLICABLE LCD:
6.4 to 15 inches quad lamp type
Lamp Voltage 800 Vrms
Lamp Current 4 x 7,5 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
Sample picture
FEATURES :
Remote ON/OFF
Open Lamp Detection
Horizontal Input Connector.
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-10°C ~ +50°C
-20°C ~ +85°C
95 %RH max
200 x 44 x 13 mm
Unit : mm
Weight :38,4 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
B8B-PH-K
Note
t=1mm
JST or equal
3
Connector CN2 ~ CN5
4
SM02B-BHSS-1-TB
JST or equal
Output side CN2 ~ CN5
Input side CN1:
Pin No. Symbols
Vin
CN 1-1;2;3
GND
CN 1-4;5;6
Vbr
CN 1-7
Vrmt
CN 1-8
Ratings
10.8 ~ 13.2 Vdc
Pin No.
CN 2-1
Symbols
Vhigh
Ratings
800 Vrms (7.5 mArms)
CN 2-2
Vlow
(GND)
0 ~ 3.0 Vdc
0 ~ 0.5 = OFF / 3.3 ~ Vin = ON
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0 10th September 2010
DC-AC INVERTER UNIT
PS-DA0412-06(S) (25 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Vin (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
Conditions
Vrmt
Tu (°C)
(V)
5±0.25 -10 ~ +50
5±0.25 -10 ~ +50
5±0.25 -10 ~ +50
5±0.25 -10 ~ +50
5±0.25 -10 ~ +50
Specification
Min.
Typ.
Max.
7.0
50
1.650
7.5
18.0
1.92
55
1.800
8.0
2.49
60
3.000
Unit
Note
mArms
%
Adc
kHz
Vrms
Vbr = 0 Vdc
Vbr = 3.0 Vdc
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
Note 2:
TEST CIRCUIT :
F
Vin
10.8 ~ 13.2 V
Iin
A
1000:1
PROBE
F
CN2-1
CN1-1
CN1-2
CN1-3
V
A Iout
1
~
SW4
SW3
SW 1
CN3-1
T1
CN4-1
V
b
CN4-2
SW1
CN1-8
A
~
A
~
CL1
Iout
1
RL1
SW4
a
CL1
Iout
1
Operation of unit
a
Operation
b
Non operation
SW3
CN1-7
Vbr
0 ~ 3.0 Vdc
A
~
CL1
Iout
1
RL1
CN3-2 SW4
Vrmt
0 / 3.3 Vdc
CL1
RL1
CN2-2
CN1-4
CN1-5
CN1-6
Vopen V
~
SW3
SW3
CN5-1
RL1
CN5-2 SW4
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 2.0 10th September 2010