XF7-CT30 CPU (XCONT) Board マスタ タイトルの書式設定 The XF7-CT30 board performs the total monitoring control for each board installed in the XF-700 series frames. 10/100Base-T RS-422A CPU Board BB GPI/ALM ・・ ・ Via Backboard Serial Bus communication between this board and the other slots Features XF700 series ENC&MUX frame control function •This board performs setting for each board installed in the ENC&MUX frame. Setting control •You can control each board setting through Web and remote communication messages. Monitoring control •This board can notify the external equipment of each board alarm information through SNMP Trap. •You can monitor each board status from the external equipment through SNMP MIB. Alarm contact output function •This board can output the contacts of CPU trip, power supply alarm and FAN alarm. Synchronization function This board is able to carry out operations synchronized with the reference signal (black burst.) NEC Corporation http://www.nec.com/global/prod/nw/broadcast/ XF-700 Series CPU (XCONT) Board Specifications Input signal (1) Black burst signal RS170A 1 channel Control signal (1) Monitoring control interface 10/100Base-T Ethernet (IEEE 802 3) (2) Serial port (option) RS-422A (3) CPU alarm output No-voltage contact (4) FAN alarm output No-voltage contact (5) PS unit-1 alarm output No-voltage contact (6) PS unit-2 alarm output No-voltage contact (7) CPU reset input No-voltage contact (8) General-purpose input No-voltage contact (9) General-purpose output Open collector 1 channel Operation temperature 0 ºC to 40 ºC Power supply +12V DC: 0.6 A Power consumption Approx. 9.2 W External dimensions Front board: 114 mm × 340 mm (H × D) Rear board: 116 mm × 80 mm (H × D) Weight Front board: 500 g or less 1 channel 1 channel 1 channel 1 channel 1 channel 1 channel 2 channels 2 channels Rear board: 200 g or less ! Safety precautions To install, make connections and operate this product, please carefully read and observe instructions, precautions and recommendations in our instruction manuals. ● The colours in this brochure may differ from those of the actual unit. Designs and specifications of this product is subject to change without prior notice. NEC Corporation International Sales Division Broadcast and Video Systems 7-1, Shiba 5-chome, Minato-ku, Tokyo, 108-8001, Japan Tel: +81-3-3798-5463 Fax: +81-3-3798-8476 NEC Europe Ltd. Network Solutions Division NEC House, 1 Victoria Road, London W3 6BL, United Kingdom Tel: +44-(0)20-8993-8111 Fax: +44-(0)20-8752-3735 NEC India Pvt. Limited NEC de Colombia S.A. 7th Floor, Ashoka Estate 24 Barakhamba Road, New Delhi - 110 001 Tel: +91-(0)11-2331-3633 Fax: +91-(0)11-2332-4259 Carrera 9 No. 80 – 32 Bogotá, D.C. – Colombia Tel: +57-1-644-5600 Fax: +57-1-644-5648 © 2012 NEC Corporation. NEC and the NEC logo are registered trademarks of NEC Corporation. HO1-560157-101