Multi-rate Gigabit Ethernet & Fibre Channel SFP CWDM Transceivers with Digital Diagnostics TRP1G1xxXIxG CWDM Pb Product Description The TRP1G1xxXIxG SFP series of multi-rate fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick and reliable interface for Gigabit Ethernet and 1.062GBd Fibre Channel applications. The transceivers are designed to support data rates ranging from 1.25Gb/s down to 125Mb/s. Diagnostics monitoring functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) SFF-8472, Rev. 9.4. There are eight center wavelengths available: 1471nm, 1491nm, 1511nm, 1531nm, 1551nm, 1571nm, 1591nm and 1611nm. Three optical link power budget options are offered, YX (22dB minimum), ZX (24dB minimum) and VX (32dB minimum). They correspond to transmission distances of 62km, 70km and 120km, respectively (assuming a total connector/splice/CWDM mux and demux loss of 4.5dB, allocated system penalty of 2dB and fiber loss of 0.25dB/km). All modules satisfy Class I Laser Safety requirements in accordance with the U.S. FDA/CDRH and international IEC-60825 standards. The TRP1G1xxXIxG CWDM transceivers connect to standard 20pad SFP connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing the power supply from the host system. The transceivers have colored bail-type latches, which offer an easy and convenient way to release the modules. The latch is compliant with the SFP MSA. Features Industrial Operating Temperature Range Lead Free Design & Fully RoHS Compliant Eight (8) Wavelength CWDM Transceivers Compatible with SFP MSA Compatible with IEEE 802.3z Gigabit Ethernet 1000BASE-LX PMD Specifications Compatible with 1.062GBd Fibre Channel 100-SM-LC-L FC-PI Standards Digital Diagnostics through Serial Interface Internal Calibration for Digital Diagnostics The transmitter and receiver DATA interfaces are AC coupled internally. LV-TTL Transmitter Disable control input and Loss of Signal output interfaces are also provided. Minimum Optical Link Power Budgets of 22dB, 24dB and 32dB to Support 62km, 70km and 120km The transceivers operate from a single +3.3V power supply over an operating temperature range of -40°C to +85°C (-40°C to 0°C is ambient, and 0°C to +85°C is case). The housing is made of metal for EMI immunity. Duplex LC Optical Interface Eye Safe (Class I Laser Safety) Loss of Signal Output & TX Disable Input Hot-pluggable Single +3.3V Power Supply Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Tst - 40 + 85 °C Operating Case Temperature Top - 40 + 85 °C Supply Voltage Vcc 0 + 4.5 V Input Voltage Vin 0 Vcc V Storage Temperature 1 -40°C to 0°C is ambient, and 0°C to +85°C is case temperature. For case temperature, measure on top side of SFP module at the front center vent hole of the cage. 1 S0137. Rev. 04 (web) 2013-02-15 TRP1G1xxXIxG CWDM Transmitter Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units B 125 - 1250 Mb/s - 2.0 - + 3.0 0 - + 5.0 VX 0 - + 5.0 1271nm 1264.5 1271 1277.5 1291nm 1284.5 1291 1297.5 1311nm 1304.5 1311 1317.5 1331nm 1324.5 1331 1337.5 1351nm 1344.5 1351 1357.5 1371nm 1364.5 1371 1377.5 1391nm 1384.5 1391 1397.5 1411nm 1404.5 1411 1417.5 1431nm 1424.5 1431 1437.5 1444.5 1451 1457.5 1471nm 1464.5 1471 1477.5 1491nm 1484.5 1491 1497.5 1511nm 1504.5 1511 1517.5 1531nm 1524.5 1531 1537.5 1551nm 1544.5 1551 1557.5 1571nm 1564.5 1571 1577.5 1591nm 1584.5 1591 1597.5 1611nm 1604.5 1611 1617.5 Δλ20 - - 1.0 nm Side Mode Suppression Ratio SMSR 30 - - dB Extinction Ratio Phi /Plo 9 - - dB Deterministic Jitter DJ - - 80 ps Total Jitter TJ - - 227 ps Optical Rise/Fall Time (20% to 80%) tr ,tf - - 0.32 ns Relative Intensity Noise RIN - - - 120 dB/Hz - - - 1.5 dB Operating Data Rate YX Optical Output Power 1 Center Wavelength 1451nm Spectral Width (-20dB) Dispersion Penalty ZX 2 Po λC Transmitter Output Eye dBm nm Compliant with Eye Mask Defined in IEEE 802.3z Standard Measured average power coupled into single mode fiber. 2 Specified at 1360ps/nm (YX), 1540ps/nm (ZX) and 2600ps/nm dispersion, which corresponds to the approximate worst-case dispersion for 62km, 70km and 120km G .652 fiber over the wavelength range of 1464.5 to 1617.5nm 1 Oplink Communications, Inc 2 S0137. Rev. 04 (web) 2013-02-15 TRP1G1xxXIxG CWDM Receiver Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Parameter Operating Data Rate Minimum Input Optical Power (10-12 BER)1 YX, ZX Maximum Input Optical Power (10-12 BER)1 YX, ZX LOS Thresholds VX VX Increasing Light Input YX, ZX Decreasing Light Input YX, ZX VX VX Symbol Minimum Typical Maximum Units B 125 - 1250 Mb/s - 24.0 - - - 32.0 - 35.0 - - 3.0 - - - 10.0 - - - - - 24.0 - - - 32.0 - 35.0 - - - 45.0 - - Pmin Pmax Plos+ Plos- dBm dBm dBm Increasing Light Input t_loss_off - - 100 Decreasing Light Input t_loss_on - - 100 - 0.5 - - dB Deterministic Jitter DJ - - 170 ps Total Jitter TJ - - 266 ps Wavelength of Operation λ 1260 - 1620 nm ORL 12 - - dB - - - 1500 MHz LOS Timing Delay LOS Hysteresis Optical Return Loss Electrical 3dB Upper Cutoff Frequency 1 µs When measured with 27-1 PRBS at 125Mb/s, 1062.5Mb/s and 1250Mb/s. Oplink Communications, Inc 3 S0137. Rev. 04 (web) 2013-02-15 TRP1G1xxXIxG CWDM Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Input Voltage Swing (TD+ & TD-)1 VPP-DIF 0.50 - 2.4 V Input HIGH Voltage (TX Disable) VIH 2.0 - VCC V 2 2 Input LOW Voltage (TX Disable) VIL 0 - 0.8 V Output HIGH Voltage (TX Fault)3 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault) VOL 0 - 0.8 V 3 Differential peak-to-peak voltage. There is an internal 4.7 to 10kΩ pull-up resistor to VccT. 3 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). 1 2 Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units VPP-DIF 0.6 - 2.0 V Output HIGH Voltage (LOS) VOH 2.0 - VCC + 0.3 V Output LOW Voltage (LOS)2 VOL 0 - 0.5 V Output Voltage Swing (RD+ & RD-)1 2 Differential peak-to-peak voltage across external 100Ω load. Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). 1 2 Electrical Power Supply Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units VCC 3.13 3.3 3.47 V - 200 300 - - 550 Supply Voltage 0°C to +85°C Supply Current ICC - 40°C to 0°C mA Module Definition MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host TTL LOW SCL SDA Serial module definition protocol Electrical Pad Layout Host Board Connector Pad Layout 20 TX GND 1 TX GND 19 TD- (TX DATA IN-) 2 TX Fault 1 18 TD+ (TX DATA IN+) 3 TX Disable 2 17 TX GND 4 MOD_DEF(2) 3 16 VccTX 5 MOD_DEF(1) Toward Bezel 4 5 15 VccRX 6 MOD_DEF(0) 14 RX GND 7 NO CONNECTION 6 13 RD+ (RX DATA OUT+) 8 LOS 7 12 RD- (RX DATA OUT-) 9 RX GND 8 11 RX GND 10 RX GND 9 10 Top of Board Oplink Communications, Inc 20 19 18 17 16 15 Toward ASIC 14 13 12 11 Bottom of Board (as viewed thru top of board) 4 S0137. Rev. 04 (web) 2013-02-15 TRP1G1xxXIxG CWDM Example of SFP host board schematic Vcc 3.3V 1 µH coil or ferrite bead (<0.2 Ω series resistance) Vcc 3.3V + 10 0.1 0.1 + 10 0.1 50Ω line TX DATA IN+ R: 4.7 to 10kΩ CAP Values in µF 15 R R 50Ω line R R TX Fault 2 8 LOS 4 5 MOD_DEF(2) MOD_DEF(1) TRP1G1xxXI 3 MR CWDM 6 TX Disable TX DATA IN- R 16 MOD_DEF(0) 50Ω line 18 13 19 12 50Ω line RX DATA OUT+ to 50Ω load RX DATA OUTto 50 Ωload 1, 9,10,11,14,17,20 Application Notes Electrical Interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally with 0.1μF and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10kΩ resistor on the host board. MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter power, average receiver signal, all alarms and warnings, and software monitoring of TX Fault/LOS. The device is internally calibrated. TX Fault: The output indicates LOW when the transmitter is operating normally, and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up with a 4.7 - 10kΩ resistor on the host board. TX Fault is non-latching (automatically deasserts when fault goes away). The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.4. TX Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -35dBm, -45dBm for F7G). Optical output is disabled from cold start until operating wavelength is within specified range. Power supply and grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, Oplink Communications, Inc. Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements Oplink Communications, Inc 5 S0137. Rev. 04 (web) 2013-02-15 TRP1G1xxXIxG CWDM Package Outline 54.6 2.15 1.27 .05 MAX 13.56 .53 15.67 .62 8.51 .34 9.55 .38 1 .04 MAX 6.25±0.051 .25±.002 1 .04 FRONT EDGE OF TRANSCEIVER CAGE 47.50 1.87 REF 8.9 .35 46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: [email protected] • www.oplink.com 13.9±0.1 .546±.004 1.8 .07 41.8±0.15 1.645±.006 Dimensions in inches [mm] Default tolerances: .xxx = ± .005”, .xx = ± .01” 45±0.20 1.772±.008 Ordering Information Model Name Operating Temperature Nominal Wavelength (nm) Latch Color 22dB Link Budget (62km Reach, YX)1 24dB Link Budget (70km Reach, ZX)1 32dB Link Budget (120km Reach, VX)1 TRP1G1HYXI000L0G TRP1G1KZXI000L0G TRP1G1KVXI000L0G - 40°C to +85°C 1271 Light Violet TRP1G1HYXI000K0G TRP1G1KZXI000K0G TRP1G1KVXI000K0G - 40°C to +85°C 1291 Sky blue TRP1G1HYXI000J0G TRP1G1KZXI000J0G TRP1G1KVXI000J0G - 40°C to +85°C 1311 Lime TRP1G1HYXI000H0G TRP1G1KZXI000H0G TRP1G1KVXI000H0G - 40°C to +85°C 1331 Dark Green TRP1G1HYXI000G0G TRP1G1KZXI000G0G TRP1G1KVXI000G0G - 40°C to +85°C 1351 Pink TRP1G1HYXI000F0G TRP1G1KZXI000F0G TRP1G1KVXI000F0G - 40°C to +85°C 1371 Beige TRP1G1HYXI000D0G TRP1G1KZXI000D0G TRP1G1KVXI000D0G - 40°C to +85°C 1391 White TRP1G1HYXI000C0G TRP1G1KZXI000C0G TRP1G1KVXI000C0G - 40°C to +85°C 1411 Silver TRP1G1HYXI000B0G TRP1G1KZXI000B0G TRP1G1KVXI000B0G - 40°C to +85°C 1431 Black TRP1G1HYXI000A0G TRP1G1KZXI000A0G TRP1G1KVXI000A0G - 40°C to +85°C 1451 Magenta TRP1G1HYXI00010G TRP1G1KZXI00010G TRP1G1KVXI00010G - 40°C to +85°C 1471 Gray TRP1G1HYXI00020G TRP1G1KZXI00020G TRP1G1KVXI00020G - 40°C to +85°C 1491 Violet TRP1G1HYXI00030G TRP1G1KZXI00030G TRP1G1KVXI00030G - 40°C to +85°C 1511 Blue TRP1G1HYXI00040G TRP1G1KZXI00040G TRP1G1KVXI00040G - 40°C to +85°C 1531 Green TRP1G1HYXI00050G TRP1G1KZXI00050G TRP1G1KVXI00050G - 40°C to +85°C 1551 Yellow TRP1G1HYXI00060G TRP1G1KZXI00060G TRP1G1KVXI00060G - 40°C to +85°C 1571 Orange TRP1G1HYXI00070G TRP1G1KZXI00070G TRP1G1KVXI00070G - 40°C to +85°C 1591 Red TRP1G1HYXI00080G TRP1G1KZXI00080G TRP1G1KVXI00080G - 40°C to +85°C 1611 Brown The indicated transmission distance is for guidelines only, not guaranteed. It assumes a total connector/splice/CWDM mux and demux loss of 4.5dB, allocated system penalty of 2dB and fiber loss of 0.25dB/km. Longer distances can be supported if the optical link power budget is satisfied. 1 Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2013, Oplink Communications, Inc. S0137. Rev. 04 (web) 2013-02-15 6