TRP1G1HYXI000x0G

Multi-rate Gigabit Ethernet & Fibre Channel SFP
CWDM Transceivers with Digital Diagnostics
TRP1G1xxXIxG CWDM
Pb
Product Description
The TRP1G1xxXIxG SFP series of multi-rate fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick and reliable interface for Gigabit Ethernet
and 1.062GBd Fibre Channel applications. The transceivers are
designed to support data rates ranging from 1.25Gb/s down to
125Mb/s. Diagnostics monitoring functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) SFF-8472, Rev. 9.4.
There are eight center wavelengths available: 1471nm, 1491nm,
1511nm, 1531nm, 1551nm, 1571nm, 1591nm and 1611nm. Three
optical link power budget options are offered, YX (22dB minimum), ZX (24dB minimum) and VX (32dB minimum). They correspond to transmission distances of 62km, 70km and 120km,
respectively (assuming a total connector/splice/CWDM mux and
demux loss of 4.5dB, allocated system penalty of 2dB and fiber
loss of 0.25dB/km). All modules satisfy Class I Laser Safety requirements in accordance with the U.S. FDA/CDRH and international
IEC-60825 standards.
The TRP1G1xxXIxG CWDM transceivers connect to standard 20pad SFP connectors for hot plug capability. This allows the system
designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing
the power supply from the host system.
The transceivers have colored bail-type latches, which offer an
easy and convenient way to release the modules. The latch is
compliant with the SFP MSA.
Features
 Industrial Operating Temperature Range
 Lead Free Design & Fully RoHS Compliant
 Eight (8) Wavelength CWDM Transceivers
 Compatible with SFP MSA
 Compatible with IEEE 802.3z Gigabit Ethernet
1000BASE-LX PMD Specifications
 Compatible with 1.062GBd Fibre Channel 100-SM-LC-L
FC-PI Standards
 Digital Diagnostics through Serial Interface
 Internal Calibration for Digital Diagnostics
The transmitter and receiver DATA interfaces are AC coupled internally. LV-TTL Transmitter Disable control input and Loss of Signal output interfaces are also provided.
 Minimum Optical Link Power Budgets of 22dB, 24dB
and 32dB to Support 62km, 70km and 120km
The transceivers operate from a single +3.3V power supply over
an operating temperature range of -40°C to +85°C (-40°C to 0°C is
ambient, and 0°C to +85°C is case). The housing is made of metal
for EMI immunity.
 Duplex LC Optical Interface
 Eye Safe (Class I Laser Safety)
 Loss of Signal Output & TX Disable Input
 Hot-pluggable
 Single +3.3V Power Supply
Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Tst
- 40
+ 85
°C
Operating Case Temperature
Top
- 40
+ 85
°C
Supply Voltage
Vcc
0
+ 4.5
V
Input Voltage
Vin
0
Vcc
V
Storage Temperature
1
-40°C to 0°C is ambient, and 0°C to +85°C is case temperature. For case temperature, measure on top side of SFP module at the front center vent hole
of the cage.
1
S0137. Rev. 04 (web) 2013-02-15
TRP1G1xxXIxG CWDM
Transmitter Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
B
125
-
1250
Mb/s
- 2.0
-
+ 3.0
0
-
+ 5.0
VX
0
-
+ 5.0
1271nm
1264.5
1271
1277.5
1291nm
1284.5
1291
1297.5
1311nm
1304.5
1311
1317.5
1331nm
1324.5
1331
1337.5
1351nm
1344.5
1351
1357.5
1371nm
1364.5
1371
1377.5
1391nm
1384.5
1391
1397.5
1411nm
1404.5
1411
1417.5
1431nm
1424.5
1431
1437.5
1444.5
1451
1457.5
1471nm
1464.5
1471
1477.5
1491nm
1484.5
1491
1497.5
1511nm
1504.5
1511
1517.5
1531nm
1524.5
1531
1537.5
1551nm
1544.5
1551
1557.5
1571nm
1564.5
1571
1577.5
1591nm
1584.5
1591
1597.5
1611nm
1604.5
1611
1617.5
Δλ20
-
-
1.0
nm
Side Mode Suppression Ratio
SMSR
30
-
-
dB
Extinction Ratio
Phi /Plo
9
-
-
dB
Deterministic Jitter
DJ
-
-
80
ps
Total Jitter
TJ
-
-
227
ps
Optical Rise/Fall Time (20% to 80%)
tr ,tf
-
-
0.32
ns
Relative Intensity Noise
RIN
-
-
- 120
dB/Hz
-
-
-
1.5
dB
Operating Data Rate
YX
Optical Output Power 1
Center Wavelength
1451nm
Spectral Width (-20dB)
Dispersion Penalty
ZX
2
Po
λC
Transmitter Output Eye
dBm
nm
Compliant with Eye Mask Defined in IEEE 802.3z Standard
Measured average power coupled into single mode fiber.
2
Specified at 1360ps/nm (YX), 1540ps/nm (ZX) and 2600ps/nm dispersion, which corresponds to the approximate worst-case dispersion for 62km,
70km and 120km G .652 fiber over the wavelength range of 1464.5 to 1617.5nm
1
Oplink Communications, Inc
2
S0137. Rev. 04 (web) 2013-02-15
TRP1G1xxXIxG CWDM
Receiver Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Operating Data Rate
Minimum Input Optical
Power (10-12 BER)1
YX, ZX
Maximum Input Optical
Power (10-12 BER)1
YX, ZX
LOS Thresholds
VX
VX
Increasing
Light Input
YX, ZX
Decreasing
Light Input
YX, ZX
VX
VX
Symbol
Minimum
Typical
Maximum
Units
B
125
-
1250
Mb/s
- 24.0
-
-
- 32.0
- 35.0
-
- 3.0
-
-
- 10.0
-
-
-
-
- 24.0
-
-
- 32.0
- 35.0
-
-
- 45.0
-
-
Pmin
Pmax
Plos+
Plos-
dBm
dBm
dBm
Increasing Light Input
t_loss_off
-
-
100
Decreasing Light Input
t_loss_on
-
-
100
-
0.5
-
-
dB
Deterministic Jitter
DJ
-
-
170
ps
Total Jitter
TJ
-
-
266
ps
Wavelength of Operation
λ
1260
-
1620
nm
ORL
12
-
-
dB
-
-
-
1500
MHz
LOS Timing Delay
LOS Hysteresis
Optical Return Loss
Electrical 3dB Upper Cutoff Frequency
1
µs
When measured with 27-1 PRBS at 125Mb/s, 1062.5Mb/s and 1250Mb/s.
Oplink Communications, Inc
3
S0137. Rev. 04 (web) 2013-02-15
TRP1G1xxXIxG CWDM
Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Input Voltage Swing (TD+ & TD-)1
VPP-DIF
0.50
-
2.4
V
Input HIGH Voltage (TX Disable)
VIH
2.0
-
VCC
V
2
2
Input LOW Voltage (TX Disable)
VIL
0
-
0.8
V
Output HIGH Voltage (TX Fault)3
VOH
2.0
-
VCC + 0.3
V
Output LOW Voltage (TX Fault)
VOL
0
-
0.8
V
3
Differential peak-to-peak voltage.
There is an internal 4.7 to 10kΩ pull-up resistor to VccT.
3
Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
1
2
Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
VPP-DIF
0.6
-
2.0
V
Output HIGH Voltage (LOS)
VOH
2.0
-
VCC + 0.3
V
Output LOW Voltage (LOS)2
VOL
0
-
0.5
V
Output Voltage Swing (RD+ & RD-)1
2
Differential peak-to-peak voltage across external 100Ω load.
Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
1
2
Electrical Power Supply Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter
Symbol
Minimum
Typical
Maximum
Units
VCC
3.13
3.3
3.47
V
-
200
300
-
-
550
Supply Voltage
0°C to +85°C
Supply Current
ICC
- 40°C to 0°C
mA
Module Definition
MOD_DEF(0)
pin 6
MOD_DEF(1)
pin 5
MOD_DEF(2)
pin 4
Interpretation by Host
TTL LOW
SCL
SDA
Serial module definition protocol
Electrical Pad Layout
Host Board Connector Pad Layout
20
TX GND
1
TX GND
19
TD- (TX DATA IN-)
2
TX Fault
1
18
TD+ (TX DATA IN+)
3
TX Disable
2
17
TX GND
4
MOD_DEF(2)
3
16
VccTX
5
MOD_DEF(1)
Toward
Bezel
4
5
15
VccRX
6
MOD_DEF(0)
14
RX GND
7
NO CONNECTION
6
13
RD+ (RX DATA OUT+)
8
LOS
7
12
RD- (RX DATA OUT-)
9
RX GND
8
11
RX GND
10
RX GND
9
10
Top of Board
Oplink Communications, Inc
20
19
18
17
16
15
Toward
ASIC
14
13
12
11
Bottom of Board
(as viewed thru top of board)
4
S0137. Rev. 04 (web) 2013-02-15
TRP1G1xxXIxG CWDM
Example of SFP host board schematic
Vcc
3.3V
1 µH coil or ferrite bead
(<0.2 Ω series resistance)
Vcc
3.3V
+
10
0.1
0.1
+
10
0.1
50Ω line
TX DATA IN+
R: 4.7 to 10kΩ
CAP Values in µF
15
R
R
50Ω line
R
R
TX Fault
2
8
LOS
4
5
MOD_DEF(2)
MOD_DEF(1)
TRP1G1xxXI
3 MR CWDM 6
TX Disable
TX DATA IN-
R
16
MOD_DEF(0)
50Ω line
18
13
19
12
50Ω line
RX DATA OUT+
to 50Ω load
RX DATA OUTto 50 Ωload
1, 9,10,11,14,17,20
Application Notes
Electrical Interface: All signal interfaces are compliant with
the SFP MSA specification. The high speed DATA interface
is differential AC-coupled internally with 0.1μF and can be
directly connected to a 3.3V SERDES IC. All low speed control
and sense output signals are open collector TTL compatible
and should be pulled up with a 4.7 - 10kΩ resistor on the host
board.
MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power
up, MOD_DEF(1:2) appear as NC (no connection), and
MOD_DEF(0) is TTL LOW. When the host system detects this
condition, it activates the serial protocol (standard two-wire
I2C serial interface) and generates the serial clock signal (SCL).
The positive edge clocks data into the EEPROM segments of
the SFP that are not write protected, and the negative edge
clocks data from the SFP.
Loss of Signal (LOS): The Loss of Signal circuit monitors the
level of the incoming optical signal and generates a logic HIGH
when an insufficient photocurrent is produced.
The serial data signal (SDA) is for serial data transfer. The
host uses SDA in conjunction with SCL to mark the start and
end of serial protocol activation. The supported monitoring
functions are temperature, voltage, bias current, transmitter
power, average receiver signal, all alarms and warnings, and
software monitoring of TX Fault/LOS. The device is internally
calibrated.
TX Fault: The output indicates LOW when the transmitter
is operating normally, and HIGH with a laser fault including
laser end-of-life. TX Fault is an open collector/drain output
and should be pulled up with a 4.7 - 10kΩ resistor on the host
board. TX Fault is non-latching (automatically deasserts when
fault goes away).
The data transfer protocol and the details of the mandatory
and vendor specific data structures are defined in the SFP MSA,
and SFF-8472, Rev. 9.4.
TX Disable: When the TX Disable pin is at logic HIGH, the
transmitter optical output is disabled (less than -35dBm,
-45dBm for F7G). Optical output is disabled from cold start
until operating wavelength is within specified range.
Power supply and grounding: The power supply line should
be well-filtered. All 0.1μF power supply bypass capacitors
should be as close to the transceiver module as possible.
Serial Identification and Monitoring: The module definition
of SFP is indicated by the three module definition pins,
Oplink Communications, Inc.
Laser Safety: All transceivers are Class I Laser products per
FDA/CDRH and IEC-60825 standards. They must be operated
under specified operating conditions.
DATE OF MANUFACTURE:
This product complies with
21 CFR 1040.10 and 1040.11
Meets Class I Laser Safety Requirements
Oplink Communications, Inc
5
S0137. Rev. 04 (web) 2013-02-15
TRP1G1xxXIxG CWDM
Package Outline
54.6
2.15
1.27
.05 MAX
13.56
.53
15.67
.62
8.51
.34
9.55
.38
1
.04 MAX
6.25±0.051
.25±.002
1
.04
FRONT EDGE OF
TRANSCEIVER CAGE
47.50
1.87 REF
8.9
.35
46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: [email protected] • www.oplink.com
13.9±0.1
.546±.004
1.8
.07
41.8±0.15
1.645±.006
Dimensions in inches [mm]
Default tolerances:
.xxx = ± .005”, .xx = ± .01”
45±0.20
1.772±.008
Ordering Information
Model Name
Operating
Temperature
Nominal
Wavelength
(nm)
Latch
Color
22dB Link Budget
(62km Reach, YX)1
24dB Link Budget
(70km Reach, ZX)1
32dB Link Budget
(120km Reach, VX)1
TRP1G1HYXI000L0G
TRP1G1KZXI000L0G
TRP1G1KVXI000L0G
- 40°C to +85°C
1271
Light Violet
TRP1G1HYXI000K0G
TRP1G1KZXI000K0G
TRP1G1KVXI000K0G
- 40°C to +85°C
1291
Sky blue
TRP1G1HYXI000J0G
TRP1G1KZXI000J0G
TRP1G1KVXI000J0G
- 40°C to +85°C
1311
Lime
TRP1G1HYXI000H0G
TRP1G1KZXI000H0G
TRP1G1KVXI000H0G
- 40°C to +85°C
1331
Dark Green
TRP1G1HYXI000G0G
TRP1G1KZXI000G0G
TRP1G1KVXI000G0G
- 40°C to +85°C
1351
Pink
TRP1G1HYXI000F0G
TRP1G1KZXI000F0G
TRP1G1KVXI000F0G
- 40°C to +85°C
1371
Beige
TRP1G1HYXI000D0G
TRP1G1KZXI000D0G
TRP1G1KVXI000D0G
- 40°C to +85°C
1391
White
TRP1G1HYXI000C0G
TRP1G1KZXI000C0G
TRP1G1KVXI000C0G
- 40°C to +85°C
1411
Silver
TRP1G1HYXI000B0G
TRP1G1KZXI000B0G
TRP1G1KVXI000B0G
- 40°C to +85°C
1431
Black
TRP1G1HYXI000A0G
TRP1G1KZXI000A0G
TRP1G1KVXI000A0G
- 40°C to +85°C
1451
Magenta
TRP1G1HYXI00010G
TRP1G1KZXI00010G
TRP1G1KVXI00010G
- 40°C to +85°C
1471
Gray
TRP1G1HYXI00020G
TRP1G1KZXI00020G
TRP1G1KVXI00020G
- 40°C to +85°C
1491
Violet
TRP1G1HYXI00030G
TRP1G1KZXI00030G
TRP1G1KVXI00030G
- 40°C to +85°C
1511
Blue
TRP1G1HYXI00040G
TRP1G1KZXI00040G
TRP1G1KVXI00040G
- 40°C to +85°C
1531
Green
TRP1G1HYXI00050G
TRP1G1KZXI00050G
TRP1G1KVXI00050G
- 40°C to +85°C
1551
Yellow
TRP1G1HYXI00060G
TRP1G1KZXI00060G
TRP1G1KVXI00060G
- 40°C to +85°C
1571
Orange
TRP1G1HYXI00070G
TRP1G1KZXI00070G
TRP1G1KVXI00070G
- 40°C to +85°C
1591
Red
TRP1G1HYXI00080G
TRP1G1KZXI00080G
TRP1G1KVXI00080G
- 40°C to +85°C
1611
Brown
The indicated transmission distance is for guidelines only, not guaranteed. It assumes a total connector/splice/CWDM mux and demux loss of
4.5dB, allocated system penalty of 2dB and fiber loss of 0.25dB/km. Longer distances can be supported if the optical link power budget is satisfied.
1
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements
of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.
© 2013, Oplink Communications, Inc.
S0137. Rev. 04 (web) 2013-02-15
6