TRPRG1xAxC000E2G

TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
Document History
Date
Status
Author
2011/12/06
Version 01
Yingying Cai
Remarks
Preliminary Specifications
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 1 of 6
S0306. Rev.01. 2011-12-06
TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
Features

Up to 1.25Gb/s bi-directional data links

Lead Free Design & Compliant with RoHS Directive 2002/95/EC

Compatible with SFP MSA

Compatible with IEEE 802.3-2002 and IEEE 802.3ab Gigabit Ethernet and 1000BASE-T Specifications

Hot-pluggable SFP footprint

TX Disable and RX Los/without Los function

Fully metallic enclosure for low EMI

Low power dissipation (1.05W typical)

Compact RJ-45 connector assembly

Access to physical layer IC via 2-wire serial bus

1000 BASE-T operation in host systems with SERDES interface

10/100/1000Mbps compliant in host systems with SGMII interface

Operating case temperature range of 0°C to +70°C (Commercial) or -40°C to +85°C (Industrial)
Description
TRPRG1-G Copper Small Form Pluggable (SFP)
transceivers is high performance, cost effective module
compliant with the Gigabit Ethernet and 1000BASE-T
standards as specified in IEEE 802.3-2002 and IEEE
802.3ab, which supports 1000Mbps data-rate up to 100
meters reach over unshielded twisted-pair category 5
cable. The module supports 1000Mbps full duplex datalinks with 5-level Pulse Amplitude Modulation (PAM)
signals. All four pairs in the cable are used with symbol
rate at 250Mbps on each pair. The module provides
standard serial ID information compliant with SFP MSA,
which can be accessed with address of A0h via the 2wire
serial CMOS EEPROM protocol. The physical IC can also
be accessed via 2-wire serial bus at address ACh.
All modules satisfy Class I Laser Safety requirements in
accordance with the U.S. FDA/CDRH and international
IEC-60825 standards.
The transceivers operate from a single +3.3V power
supply over an operating case temperature range of 0°C
to +70°C (Commercial) or -40°C to +85°C (Industrial). The
housing is made of metal for EMI immunity.
Absolute Maximum Ratings
Parameters
Storage Temperature
1
Operating Case Temperature
1
Commercial
Industrial
Symbol
Min
Max
Units
TST
- 40
+ 85
°C
0
+ 70
- 40
+ 85
TOP
°C
Measured on top side of SFP module at the front center vent hole of the cage.
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 2 of 6
S0306. Rev.01. 2011-12-06
TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
General specifications
Parameter
Symbol
Min
Typ
Max
Units
1.2.
B
10
-
1000
Mb/s
L
-
-
100
m
Operating Data Rate
Cable Length
3
1
Clock tolerance is +/- 50 ppm.
2
Automatic cross over detection is enabled. External crossover cable is not required.
3
Category 5 UTP. BER<10-12.
+3.3V Volt Electrical Power Interface
Symbol
Min
Typ
Max
Units
Supply Voltage
Parameter
VCC
3.13
3.3
3.47
V
Supply Current
Icc
-
320
375
mA
-
Vmax
-
-
4
V
-
Maximum Voltage
Notes/Conditions
Referenced to GND
High-speed electrical interface, transmission line-SFP
Parameter
Symbol
Min
Typ
Max
Units
fL
-
125
-
MHz
5-level encoding, per IEEE 802.3
Tx Output Impedance
Zout,TX
-
100
-
Ohm
Differential, for all Frequencies
between 1MHz and 125MHz
Rx Input Impedance
Zin,RX
-
100
-
Ohm
Differential, for all Frequencies
between 1MHz and 125MHz
Line Frequency
Notes/Conditions
High-speed electrical interface, host-SFP
Parameter
Single ended data input swing
Single ended data output swing
Symbol
Min
Typ
Max
Units
Notes/Conditions
Vinsing
Voutsing
250
350
-
1200
800
mV
mV
Single ended
Single ended
Tr,Tf
-
175
-
psec
20%-80%
Tx Input Impedance
Zin
-
50
-
Ohm
Single ended
Rx Output Impedance
Zout
-
50
-
Ohm
Single ended
Notes/Conditions
4.7k to 10k pull-up to host_Vcc,
measured at host side of connector
4.7k to 10k pull-up to host_Vcc,
measured at host side of connector
4.7k to 10k pull-up to Vcc,
measured at SFP side of connector
4.7k to 10k pull-up to Vcc,
measured at SFP side of connector
Rise/Fall Time
Low-speed signals, electronic characteristics
Parameter
Symbol
Min
Max
Units
SFP Output LOW
VOL
0
0.5
V
SFP Output HIGH
VOH
host_Vcc-0.5
host_Vcc +
0.3
V
SFP Input LOW
VIL
0
0.8
V
SFP Input HIGH
VIH
2
Vcc + 0.3
V
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 3 of 6
S0306. Rev.01. 2011-12-06
TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
Package Outline
Electrical Pad Layout
Host Board Connector Pad Layout
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 4 of 6
S0306. Rev.01. 2011-12-06
TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
Pin Descriptions
Pin
Signal Name
Description
Plug Seq.
1
VEET
Transmitter Ground
1
2
TX FAULT
Transmitter Fault Indication
3
3
TX DISABLE
Transmitter Disable
3
4
MOD_DEF(2)
SDA Serial Data Signal
3
5
MOD_DEF(1)
SCL Serial Clock Signal
3
6
MOD_DEF(0)
TTL Low
3
7
Rate Select
Not Connected
3
8
LOS
Loss of Signal
3
9
VEER
Receiver ground
1
10
VEER
Receiver ground
1
11
VEER
Receiver ground
1
12
RD-
Inv. Received Data Out
3
13
RD+
Received Data Out
3
14
VEER
Receiver ground
1
15
VCCR
Receiver Power Supply
2
16
VCCT
Transmitter Power Supply
2
17
VEET
Transmitter Ground
1
18
TD+
Transmit Data In
3
19
TD-
Inv. Transmit Data In
3
20
VEET
Transmitter Ground
1
Notes:
Plug Seq.: Pin engagement sequence during hot plugging.
Application Notes
Loss of Signal (LOS): LVTTL compatible with a
maximum voltage of 2.5V. LOS pin can enabled or
disabled (Refer to Ordering information).
TX_Fault: TX_Fault pin is not supported, and is always
connected to ground.
TX_Disable: It is an input used to reset the transceiver
module. This pin is pulled up within the module with a 4.7
KΩ resistor. Low (0 – 0.8 V): Transceiver on; Between 0.8
V and 2.0 V: Undefined; High (2.0 – 3.465 V): Transceiver
in reset state; Open: Transceiver in reset state.
Serial Identification and Monitoring: The module
definition of SFP is indicated by the three module
definition pins, MOD_DEF(0), MOD_DEF(1) and
MOD_DEF(2).
They should be pulled up with a 4.7K~10K resistor on the
host board. The pull-up voltage shall be VccT or VccR.
MOD_DEF(0) is grounded by the module to indicate that
the module is present. MOD_DEF(1) is the clock line of
two wire serial interface for serial ID. MOD_DEF(2) is the
data line of two wire serial interface for serial ID.
RD-/+: These are the differential receiver outputs. They
are AC coupled 100 differential lines which should be
terminated with 100 (differential) at the user SERDES.
TD-/+: These are the differential transmitter inputs. They
are AC-coupled, differential lines with 100 differential
terminations inside the module.
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 5 of 6
S0306. Rev.01. 2011-12-06
TRPRG1-G 1.25G Ethernet
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
Ordering Information
Oplink Part Number
Speed Mode
MAC interface
TX Disable
function
Link Indicator
on RX_LOS Pin
Operating
Temperature
TRPRG1VA2C000E2G
10/100/1000Mbps
SGMII
Yes
Yes
0°C to +70°C
TRPRG1VA1C000E2G
10/100/1000Mbps
SGMII
Yes
No
0°C to +70°C
TRPRG1NA2C000E2G
1000Mbps
SERDES
Yes
Yes
0°C to +70°C
TRPRG1NA1C000E2G
1000Mbps
SERDES
Yes
No
0°C to +70°C
TRPRG1VA2I000E2G
10/100/1000Mbps
SGMII
Yes
Yes
- 40°C to +85°C
TRPRG1VA1I000E2G
10/100/1000Mbps
SGMII
Yes
No
- 40°C to +85°C
TRPRG1NA2I000E2G
1000Mbps
SERDES
Yes
Yes
- 40°C to +85°C
TRPRG1NA1I000E2G
1000Mbps
SERDES
Yes
No
- 40°C to +85°C
Oplink Communications, Inc.
46335 Landing Parkway, Fremont, CA 94538-6407 Tel: (510)933-7200, Fax: (510)933-7300, www.oplink.com
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink
Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any
infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.
©2011 Oplink Communications, Inc.
46335 Landing Pkwy‧Fremont CA 94538-6407‧Tel: 510-933-7200‧Fax: 510-933-7300‧Email: [email protected]‧Web: www.oplink.com
Page 6 of 6
S0306. Rev.01. 2011-12-06