Errata Sheet V1.1, 2005-10-10 Device C164CI-8E Marking/Step Step ES-CB, CB Package C-MQFP, P-MQFP-80 This Errata Sheet describes the deviations from the current user documentation. The module oriented classification and numbering system uses an ascending sequence over several derivatives, including already solved deviations. So gaps inside this enumeration can occur. Current Documentation • C164CI/CL, SI/SL Data Sheet, V2.0, May 20011) • C164CI/CL, SI/SL User’s Manual, V3.1, Feb. 2002 • Instruction Set Manual, V2.0, Mar. 2001 Note: Devices marked with EES- or ES are engineering samples which may not be completely tested in all functional and electrical characteristics, therefore they should be used for evaluation only. The specific test conditions for EES and ES are documented in a separate Status Sheet. Note: For simplicity all versions are referred to by the term C164CI-8E throughout this document. Contents Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page History List/Change Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Functional Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Deviations from Electrical- and Timing Specification. . . . . . . . . . . . . . . . . . . . . . .19 Application Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Documentation Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 1) see introduction in DOC_OTP.D1 C164CI-8E, Step ES-CB, CB 1/30 es, V1.1, 2005-10-10 Errata Sheet History List/Change Summary 1 History List/Change Summary (from step ES-BB, previous errata sheet V1.0, step: CB) Table 1 Functional Deviations Functional Problem Short Description ADC.11 Modifications of ADM field while bit ADST = 0 SSC.9 Data Transmission in Slave Mode CAN.7 Unexpected Remote Frame Transmission CAN.9 Contents of Message Objects and Mask of Last Message Registers after Reset Fixed Change in step CAPCOM.2 Wakeup from Idle Mode by CAPCOM2 channels CC19 or CC27 CA CAPCOM6.3 Write Access to CAPCOM6 Registers CA RTC.2 Read RTC count registers CA RTC.4 Undefined Results after write to T14 BUS.17 Spikes on CS lines after access with RDCS and/or WRCS BUS.18 PEC transfers after JMPR X9 Read Access to XPERs in Visible Mode OTP.7 Verify in CHM when Bootstrap Loader Mode is selected OTP.8 Programming Voltage VPP and Supply Voltage VDD CPU.16 Data read access with MOVB [Rn], mem instruction to internal ROM/Flash/OTP CB CPU.17 Arithmetic Overflow by DIVLU instruction CB CPU.21 BFLDL/BFLDH Instructions after Write Operation to internal IRAM CB CPU.22 Z Flag after PUSH and PCALL PLL.3.1 Increased PLL Jitter caused by external Access PWRDN.1 Execution of PWRDN instruction while Pin NMI = high RST.4 Power on Reset RST.13.1 Power Up with missing Clock (former name: RST.13) C164CI-8E, Step ES-CB, CB CA CA 2/30 name changed es, V1.1, 2005-10-10 Errata Sheet History List/Change Summary Table 1 Functional Deviations (cont’d) Functional Problem Short Description ADP.1 Oscillator in Adapt Mode Table 2 AC/DC Deviations AC/DC Deviations Short Description DC.AH.2 ALE active current 650 µA DC.HYS.1 Input Hysteresis (Special Threshold) 300 mV DC.IOZ2.2 Input Leakage Current IOZ2 +/- 1 µA (Pin EA# only) DC.IPDR.2 see C164 Data Sheet V2.0, May 2001, DC Characteristics (IPDR = 200 + 25 x fOSC [µA]) DC.P0L.2 P0 configuration current -120 µA CA DC.P4L.2 P4 active current -650 µA CA DC.RL.2 RD#/WR# active current -650 µA CA DC.VDD.1 see C164 Data Sheet V2.0, May 2001, Operating Condition Parameters (VDD = 4.75 ... 5.5 V) DC.VILS.1 Input low voltage (Special Threshold) 1.7 V DC.VIH.1 Input high voltage VIH_min on P20.5 / EA AC.t48.1 RDCS#/WRCS# low time (with RW-delay) 2TCL12ns AC.t49.1 RDCS#/WRCS# low time (no RW-delay) 3TCL-12ns C164CI-8E, Step ES-CB, CB Fixed Change in step CA Fixed Change in step CA 3/30 es, V1.1, 2005-10-10 Errata Sheet History List/Change Summary Table 3 Application Hints Hint Short Description SSC.H1 Handling of the SSC Busy Flag (SSCBSY) SSC.H2 Timing of flag SSCTIR (SSC Transmit Interrupt Request) CAN.H1 Note on Interrupt Register behaviour of the CAN module EMUL.H1 Adapt Mode Setting OTP.H1 OTP Read access in CHM Mode delivers Zeros only Change MainOsc.H1 Oscillator Type_LP2: Negative Resistance and Start-up Reliability MainOsc.H2 Maximum (Type_LP2) Oscillator Frequency = 16 MHz OWD.H2 Oscillator Watchdog and Prescaler Mode ISNC.H1 Maintenance of ISNC Register Table 4 Documentation Update Name Short Description PORT.D2 Output Driver Control INT.D1 CCxIC Registers Change DOC_OTP.D1 Differences to Data Sheet Version 2.0, May 2001 Updated: Introduction; Ports: Output high voltage updated ID-Registers updated ID-Registers C164CI-8E, Step ES-CB, CB 4/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems 2 Functional Problems ADC.11 Modifications of ADM field while bit ADST = 0 The A/D converter may unintentionally start one auto scan single conversion sequence when the following sequence of conditions is true: 1. the A/D converter has finished a fixed channel single conversion of an analog channel n > 0 (i.e. contents of ADCH (ADCON.3-0) = n during this conversion) 2. the A/D converter is idle (i.e. ADBSY (ADCON.8) = 0) 3. then the conversion mode in the ADC Mode Selection field ADM (ADCON.5-4) is changed to Auto Scan Single (ADM = 10B) or Continuous (ADM = 11B) mode without setting bit ADST = 1 with the same instruction Under these conditions, the A/D converter will unintentionally start one auto scan single conversion sequence, beginning with channel n-1, down to channel number 0. When no interrupt or PEC is servicing the A/D Conversion Complete Interrupt, interrupt request flag ADCIR (ADCIC.7) will be set, and for n > 1 also the A/D Overrun Error interrupt request flag will be set, unless the wait for ADDAT read mode had been selected. When ADWR (ADCON.9) = 1 (wait for ADDAT read), the converter will wait after 2 conversions until ADDAT is read. In case the channel number ADCH has been changed before or with the same instruction which selected the auto scan mode, this channel number has no effect on the unintended auto scan sequence (i.e. it is not used in this auto scan sequence). Note: When a conversion is already in progress, and then the configuration in register ADCON is changed, • the new conversion mode in ADM is evaluated after the current conversion • the new channel number in ADCH and new status of bit ADST are evaluated after the current conversion when a conversion in fixed channel conversion mode is in progress, and after the current conversion sequence (i.e. after conversion of channel 0) when a conversion in an auto scan mode is in progress. In this case, it is a specified operational behaviour that channels n-1 .. 0 are converted when ADM is changed to an auto scan mode while a fixed channel conversion of channel n is in progress (see e.g. C164CI User's Manual, V1.0, p.18-4) Workaround: When an auto scan conversion is to be performed, always start the A/D converter with the same instruction which sets the configuration in register ADCON. C164CI-8E, Step ES-CB, CB 5/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems SSC.9 Data Transmission in Slave Mode During data reception in slave mode of the SSC module, sporadically the shift clock supplied by the external master on pin SCLK may not be properly recognized due to a synchronization problem when all of the following conditions are true: 1. the latching edge for the serial data is the falling edge of SCLK (i.e. both bit SSCPO = 1 and bit SSCPH = 1, or SSCPO = 0 and SSCPH = 0 in register SSCCON), and 2. the transmit buffer SSCTB of the slave has not been written prior to the start of the reception (initiated by the master asserting the shift clock SCLK), and 3. a specific time window (phase delay) is hit by the serial shift clock SCLK in relation to the internal system clock of the slave. Therefore, this synchronization problem will occur in particular when the slave device is clocked (on XTAL1) by an external clock generation circuit which is independent from the clock generation circuit of the master (i.e. slave and master clocks are asynchronous). When the problem occurs, this results in missing bits in the character received in SSCTB, and in duplicated bits in the character transmitted on pin MRST of the slave. As a consequence, interrupt generation in the slave is delayed by the number of missed bits. Workaround For systems using the falling edge of SCLK as latching edge (see condition 1. above), always write to the transmit buffer SSCTB prior to any reception in slave mode of the SSC module. For the second and all following characters, e.g. write a (dummy) character to SSCTB in the receive interrupt routine, or use a PEC transfer triggered by the transmit interrupt request to write to SSCTB. In this case, the critical synchronization path is not used, and the problem will not occur. CAN.7 Unexpected Remote Frame Transmission Symptom: The on-chip CAN module may send an unexpected remote frame with the identifier = 0, when a pending transmit request of a message object is disabled by software. Detailed Description: There are three possibilities to disable a pending transmit request of a message object (n = 1..14): • Set CPUUPDn element C164CI-8E, Step ES-CB, CB 6/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems • Reset TXRQn element • Reset MSGVALn element Either of these actions will prevent further transmissions of message object n. The symptom described above occurs when the CPU accesses CPUUPD, TXRQ or MSGVAL, while the pending transmit request of the corresponding message object is transferred to the CAN state machine (just before start of frame transmission). At this particular time the transmit request is transferred to the CAN state machine before the CPU prevents transmission. In this case the transmit request is still accepted from the CAN state machine. However the transfer of the identifier, the data length code and the data of the corresponding message object is prevented. Then the pre-charge values of the internal "hidden buffer" are transmitted instead, this causes to a remote frame transmission with identifier = 0 (11 bit) and data length code = 0. This behavior occurs only when the transmit request of message object n is pending and the transmit requests of other message objects are not active (single transmit request). If this remote frame loses arbitration (to a data frame with identifier = 0) or if it is disturbed by an error frame, it is not retransmitted. Effects to other CAN nodes in the network: The effect leads to delays of other pending messages in the CAN network due to the high priority of the Remote Frame. Furthermore the unexpected remote frame can trigger other data frames depending on the CAN node's configuration. Workarounds: • The behavior can be avoided if a message object is not updated by software when a transmission of the corresponding message object is pending (TXRQ element is set) and the CAN module is active (INIT = 0). If a re-transmission of a message (e.g. after lost arbitration or after the occurrence of an error frame) needs to be cancelled, the TXRQ element should be cleared by software as soon as NEWDAT is reset from the CAN module. • The nodes in the CAN system ignore the remote frame with the identifier = 0 and no data frame is triggered by this remote frame. CAN.9 Contents of Message Objects and Mask of Last Message Registers after Reset After any reset, the contents of the CAN Message Objects and the Mask of Last Message Registers may be undefined instead of unaffected (reset value 'X' instead of 'U'). C164CI-8E, Step ES-CB, CB 7/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems This problem depends on temperature and the length of the reset, and differs from device to device. The problem is more likely to occur at high temperature and for long hardware resets (> 100 ms). Workaround: Re-initialize the CAN module after each reset. RTC.4 Undefined Results after write to T14 A write operation to T14 leads to undefined results depending on contents of T14REL. Workaround: Load T14REL (1st) and T14 (2nd) with the desired value. E.g. MOV MOV T14REL, #xxxx T14, #xxxx BUS.17 Spikes on CS Lines after access with RDCS and/or WRCS Spikes of about 5 ns width (measured at VOH = 0.9 VCC) from VCC to VSS may occur on Port 6 lines configured as CS signals. The spikes occur on one CSx line at a time for the first external bus access which is performed via a specific BUSCONx/ADDRSELx register pair (x=1..4) or via BUSCON0 (x=0) when the following two conditions are met: 1. the previous bus cycle was performed in a non-multiplexed bus mode without tristate waitstate via a different BUSCONy/ADDRSELy register pair (y=1..4, y≠x) or BUSCON0 (y=0, y≠x) and 2. the previous bus cycle was a read cycle with RDCSy (bit BUSCONy.CSRENy = 1) or a write cycle with WRCS (bit BUSCONy.CSWENy = 1). The position of the spikes is at the beginning of the new bus cycle which is performed via CSx, synchronous with the rising edge of ALE and synchronous with the rising edge of RD/WR of the previous bus cycle. Potential effects on applications: - when CS lines are used as CE signals for external memories, typically no problems are expected, since the spikes occur after the rising edge of the RD or WR signal. - when CS lines configured as RDCS and/or WRCS are used e.g. as OE signals for external devices or as clock input for shift registers, problems may occur (temporary bus C164CI-8E, Step ES-CB, CB 8/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems contention for read cycles, unexpected shift operations, etc.). When CS lines configured as WRCS are used as WE signals for external devices, no problems are expected, since a tristate waitstate should be used anyway due to the negative address hold time after WRCS (t55) without tristate WS. Workarounds: 1. Use a memory tristate WS (i.e. leave bit BUSCONy.5 = 0) in all active BUSCON registers where RD/WR-CS is used (i.e. bit BUSCONy.CSRENy = 1 and/or bit BUSCONy.CSWENy = 1), or 2. Use Address-CS instead of RD/WR-CS (i.e. leave bits BUSCONy[15:14] = 00b) for all BUSCONy registers where a non-multiplexed bus without tristate WS is configured (i.e. bit BUSCONy.5 = 1). BUS.18 PEC Transfers after JMPR instruction Problems may occur when a PEC transfer immediately follows a taken JMPR instruction when the following sequence of 4 conditions is met (labels refer to following examples): 1. in an instruction sequence which represents a loop, a jump instruction (Label_B) which is capable of loading the jump cache (JMPR, JMPA, JB/JNB/JBC/JNBS) is taken 2. the target of this jump instruction directly is a JMPR instruction (Label_C) which is also taken and whose target is at address A (Label_A) 3. a PEC transfer occurs immediately after this JMPR instruction (Label_C) 4. in the following program flow, the JMPR instruction (Label_C) is taken a second time, and no other JMPR, JMPA, JB/JNB/JBC/JNBS or instruction which has branched to a different code segment (JMPS/CALLS) or interrupt has been processed in the meantime (i.e. the condition for a jump cache hit for the JMPR instruction (Label_C) is true) In this case, when the JMPR instruction (Label_C) is taken for the second time (as described in condition 4 above), and the 2 words stored in the jump cache (word address A and A+2) have been processed, the word at address A+2 is erroneously fetched and executed instead of the word at address A+4. Note: the problem does not occur when • the jump instruction (Label_C) is a JMPA instruction • the program sequence is executed from internal Flash/ROM/OTP C164CI-8E, Step ES-CB, CB 9/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems Example1: Label_A: ..... Label_B: ..... Label_C: instruction x instruction x+1 ; Begin of Loop JMP Label_C; JMP may be any of the following jump instructions: ; JMPR cc_zz, JMPA cc_zz, JB/JNB/JBC/JNBS ; jump must be taken in loop iteration n ; jump must not be taken in loop iteration n+1 JMPR ; ; ; cc_xx, Label_A ; End of Loop instruction must be JMPR (single word instruction) jump must be taken in loop iteration n and n+1 PEC transfer must occur in loop iteration n Example2: Label_A: ..... Label_C: ..... Label_B: instruction x instruction x+1 ; Begin of Loop1 JMPR cc_xx, Label_A ; End of Loop1, Begin of Loop2 ; instruction must be JMPR (single word instruction) ; jump not taken in loop iteration n-1, i.e. Loop2 is entered ; jump must be taken in loop iteration n and n+1 ; PEC transfer must occur in loop iteration n JMP Label_C ; End of Loop2 ; JMP may be any of the following jump instructions: ; JMPR cc_zz, JMPA cc_zz, JB/JNB/JBC/JNBS ; jump taken in loop iteration n-1 A code sequence with the basic structure of Example1 was generated e.g. by a compiler for comparison of double words (long variables). Workarounds: • use a JMPA instruction instead of a JMPR instruction when this instruction can be the direct target of a preceding JMPR, JMPA, JB/JNB/JBC/JNBS instruction, or • insert another instruction (e.g. NOP) as branch target when a JMPR instruction would be the direct target of a preceding JMPR, JMPA, JB/JNB/JBC/JNBS instruction, or • change the loop structure such that instead of jumping from Label_B to Label_C and then to Label_A, the jump from Label_B directly goes to Label_A. C164CI-8E, Step ES-CB, CB 10/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems Notes on compilers: In the Hightec compiler beginning with version Gcc 2.7.2.1 for SAB C16x - V3.1 Rel. 1.1, patchlevel 5, a switch -m bus18 is implemented as workaround for this problem. In addition, optimization has to be set at least to level 1 with -u1. The Keil C compiler versions < V4.0 and run time libraries do not generate or use instruction sequences where a JMPR instruction can be the target of another jump instruction, i.e. the conditions for this problem do not occur. In V4.0, the problem may occur when optimize (size or speed, 7) is selected. Lower optimization levels than 7 are not affected. In V4.01, a new directive FIXPEC is implemented which avoids this problem. In the TASKING C166 Software Development Tools, the code sequence related to problem BUS.18 can be generated in Assembly. The problem can also be reproduced in C-language by using a particular sequence of GOTOs. With V6.0r3, TASKING tested all the Libraries, C-startup code and the extensive set of internal test-suite sources and the BUS.18 related code sequence appeared to be NOT GENERATED. To prevent introduction of this erroneous code sequence, the TASKING Assembler V6.0r3 has been extended with the CHECKBUS18 control which generates a WARNING in the case the described code sequence appears. When called from within EDE, the Assembler control CHECKBUS18 is automatically 'activated'. X9 Read Access to XPERs in Visible Mode The data of a read access to an XBUS-Peripheral (CAN) in Visible Mode (SYSCON.1 = 1) is not driven to the external bus. PORT0 is tristated during such read accesses. Note that in Visible Mode PORT1 will drive the address for an access to an XBUSPeripheral, even when only a multiplexed external bus is enabled. OTP.8 Programming Voltage VPP and Supply Voltage VDD To guarantee a proper internal OTP programming the tolerances for supply voltage VDD and programming voltage VPP are reduced. C164CI-8E, Step ES-CB, CB 11/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems The following values have been successfully tested and can be recommended: Supply Voltage VDD Programming Voltage VPP 4.35V - 4.65V 11.35V - 11.65V 4.85V - 5.15V 11.8V - 12.1V Application Hints: • Devices formerly programmed with these recommended values can be used without restriction. • Software for OTP programming tools should be adapted to one of these recommended values (VDD = 4.85V - 5.15V and VPP = 11.8 - 12.1V can still be used after the problem is fixed in the future). CPU.22 Z Flag after PUSH and PCALL The Z flag in the PSW is erroneously set to '1' by PUSH reg or PCALL reg, rel instructions when all of the following conditions are true: a) for PUSH reg instructions: • the contents of the high byte of the GPR or (E)SFR which is pushed is 00H, and • the contents of the low byte of the GPR or (E)SFR which is pushed is > 00H, and • the contents of GPR Rx is odd, where x = 4 msbs of the 8-bit 'reg' address of the pushed GPR or (E)SFR Examples: PUSH PUSH R1 ;(coding: F1 ; incorrect ; and 00FFh DPP3 ;(coding: 03 ; incorrect ; and 00FFh EC): setting of ≥ contents EC): setting of ≥ contents Z flag if contents of R15 is odd, of R1 ≥ 0001h Z flag if contents of R0 is odd, of DPP3 ≥ 0001h b) for PCALL reg, rel instructions: • when the contents of the high byte of the GPR or SFR which is pushed is 00H, and • when the contents of the low byte of the GPR or SFR which is pushed is odd C164CI-8E, Step ES-CB, CB 12/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems This may lead to wrong results of instructions following PUSH or PCALL if those instructions explicitly (e.g. BMOV .. , Z; JB Z, ..; ..) or implicitly (e.g. JMP cc_Z, ..; JMP cc_NET, ..; ..) evaluate the status of the Z flag before it is newly updated. Note: Some instructions (e.g. CALL, ..) have no effect on the status flags, such that the status of the Z flag remains incorrect after a PUSH/PCALL instruction until an instruction that correctly updates the Z flag is executed. Example: PUSH R1 CALL proc_xyz ... ... proc_xyz: JMP cc_Z,end_xyz ... end_xyz: ; incorrect setting of Z flag if R15 is odd ; Z flag remains unchanged ; (is a parameter for proc_xyz) ; Z flag evaluated with incorrect setting Effect on Tools: • The Hightec C166 tools (all versions) don't use the combination of PUSH/PCALL and the evaluation of the Z flag. Therefore, these tools are not affected. • The code generated by the Keil C166 Compiler evaluates the Z flag only after MOV, CMP, arithmetic, or logical instructions. It is never evaluated after a PUSH instruction. PCALL instructions are not generated by the C166 Compiler. This has been checked with all C166 V3.xx and V4.xx compiler versions. Even the upcoming V5.xx is not affected by the CPU.22 problem. The assembler portions of the C166 V3.xx and V4.xx Run-Time Libraries, the RTX166 Full and TX166 Tiny Real Time Operating system do also not contain any evaluation of the Z flag after PUSH or PCALL. • The TASKING compiler V7.5r2 never generates a PCALL instruction, nor is it used in the libraries. The PUSH instruction is only used in the entry of an interrupt frame, and sometimes on exit of normal functions. The zero flag is not a parameter or return value, so this does not give any problems. Previous versions of TASKING tools: C164CI-8E, Step ES-CB, CB 13/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems V3.x and higher are not affected, versions before 3.x are most likely not affected. Contact TASKING when using versions before V3.x. Since code generated by the C166 compiler versions mentioned before is not affected, analysis and workarounds are only required for program parts written in assembler, or instruction sequences inserted via inline assembly. Workaround (for program parts written in assembler): Do not evaluate the status of the Z flag generated by a PUSH or PCALL instruction. Instead, insert an instruction that correctly updates the PSW flags, e.g. PUSH CMP JMPR reg reg, #0 ; note: ; CMP additionally modifies the C and V flags, ; while PUSH or MOV leaves them unaffected cc_Z, label_1; implicitly tests Z flag or PCALL reg, procedure_1 ... procedure_1: MOV ONES, reg JMPR cc_NET, label_1 ; implicitly tests flags Z and E Hints for Detection of Critical Instruction Combinations Whether or not an instruction following PUSH reg or PCALL reg, rel actually causes a problem depends on the program context. In most cases, it will be sufficient to just analyze the instruction following PUSH or PCALL. In case of PCALL, this is the instruction at the call target address. Support Tool for Analysis of Hex Files For complex software projects, where a large number of assembler source (or list) files would have to be analyzed, Infineon provides a tool aiScan22 which scans hex files for critical instruction sequences and outputs diagnostic information. This tool is available as part of the Application Note ap1679 'Scanning for Problem CPU.22' on the 16-bit microcontroller internet pages of Infineon Technologies. Follow the link: ’Application Notes - 16-bit Microcontrollers’ in: www.infineon.com/16-bit-microcontrollers C164CI-8E, Step ES-CB, CB 14/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems Individual Analysis of Assembler Source Code With respect to problem CPU.22, all instructions of the C166 instruction set can be classified into the following groups: • Arithmetic/logic/data movement instructions as successors of PUSH/PCALL (correctly) modify the condition flags in the PSW according to the result of the operation. These instructions may only cause a problem if the PSW is a source or source/ destination operand: ADD/B, ADDC/B, CMP/B, CMPD1/2, CMPI1/2, SUB/B, SUBC/B AND/B, OR/B, XOR/B ASHR MOV/B, MOVBZ/MOVBS SCXT PUSH, PCALL Î analysis must be repeated for successor of PUSH/PCALL • The following instructions (most of them with immediate or register (Rx) addressing modes) can never cause a problem: CPL/B, NEG/B DIV/U, DIVL/U, MUL/U SHL/SHR, ROL/ROR PRIOR POP RETI Î updates complete PSW with stacked value RETP Î updates condition flags PWRDN Î program restarts after reset SRST Î program restarts • Conditional branch instructions which may evaluate the Z flag: JB/JNB Z, rel ; directly evaluates Z flag CALLA/CALLI, JMPA/JMPI/JMPR with the following condition codes cc_Z, cc_EQ, cc_NZ, cc_NE cc_ULE, cc_UGT, cc_SLE, cc_SGT cc_NET Î For these branch conditions, the branch may be performed in the wrong way. Î For other branch conditions, the branch target as well as the linear successor of the branch instruction must be analyzed (since these branch instruction don't modify the PSW flags). • For instructions that have no effect on the condition flags and that don't evaluate the Z flag, the instruction that follows this instruction must be analyzed. These instructions are: C164CI-8E, Step ES-CB, CB 15/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems NOP ATOMIC, EXTxx DISWDT, EINIT, IDLE, SRVWDT CALLR, CALLS, JMPS Î branch target must be analyzed RET, RETS Î return target must be analyzed (value pushed by PUSH/PCALL = return IP, Z flag contains information whether intra-segment target address = 0000H or not) TRAP Î both trap target and linear successor must be analyzed, since Z flag may be incorrect in PSW on stack as well as in PSW at entry of trap routine • For bit modification instructions, the problem may only occur if a source bit is the Z flag, and/or the destination bit is in the PSW, but not the Z flag. These instructions are: BMOV/BMOVN BAND/BOR/BXOR BCMP BFLDH BFLDL Î problem only if bit 3 of @@ mask = 0, i.e. if Z is not selected BCLR/BSET Î problem only if operand is not Z flag JBC/JNBS Î wrong branch if operand is Z flag PLL.3.1 Increased PLL Jitter caused by external Access Problem description: In systems where the PLL is used for generation of the CPU clock frequency, the PLL jitter can increase under certain circumstances and exceed the specified value. The value of the additional jitter is not a fixed one but it depends on the kind of activity on the external bus or output pins. The additional jitter increases with the number of output/bus pins which are switched at the same time to a new voltage level because the problem is caused by noise on the on-chip power supply. The capacitive load of the used pins has also an influence to the additional jitter. A high capacitive load can increase the additional jitter. Effects to the system: All PLL factors are affected (PLL factor 1.5 / 2 / 2.5 / 3 / 4 / 5). The PLL jitter increases when an access to the external bus or output pins is performed. This phenomenon has no influence to direct drive-, prescaler-, and SDD mode. The problem does not affect the functionality of the CPU and the on-chip peripherals. C164CI-8E, Step ES-CB, CB 16/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems The additional jitter has the maximum effect if only one TCL is considered (period jitter). This can have an influence to the bus timings with one TCL. The additional jitter decreases with the number of consecutive TCLs (accumulated jitter). The accumulated jitter has an effect on timings with more than one TCL (certain bus timings, CAN bus timing, serial interfaces). New value of the additional jitter For an accumulated period of N*TCL the new maximum jitter DN[ns], which exceeds the specified value in the Data Sheet, is computed using the formula: DN[ns] = ±[(50 / fCPU + 164 / fCPU2 - 0.04) * (N / 2 - 1) + 1180 / fCPU2 + 0.2] Were N = number of consecutive TCL, fCPU = CPU frequency in MHz. This approximated formula is valid for 1 ≤ N ≤ 12 and 10 MHz ≤ fCPU ≤ 25 MHz. For all accumulated periods longer than 12 TCL the N=12 value can be used; see figure below. ±45 Max. jitter DN[ns] 10MHz ±40 ±35 ±30 ±25 16MHz ±20 20MHz 25MHz ±15 ±10 ±5 0 1 Figure 1 5 10 15 20 25 30 35 40 TCL Additional Jitter Workaround: In case that the additional jitter causes problems in the system which cannot be relaxed with software adapted timing parameters, then direct drive or prescaler mode can be used. If the maximum frequency of the on-chip oscillator (16 MHz) is not sufficient then an external clock generator can be used. C164CI-8E, Step ES-CB, CB 17/30 es, V1.1, 2005-10-10 Errata Sheet Functional Problems PWRDN.1 Execution of PWRDN Instruction while pin NMI = high When instruction PWRDN is executed while pin NMI is at a high level, power down mode should not be entered, and the PWRDN instruction should be ignored. However, under the conditions described below, the PWRDN instruction may not be ignored, and no further instructions are fetched from external memory, i.e. the CPU is in a quasi-idle state. This problem will only occur in the following situations: a) the instructions following the PWRDN instruction are located in external memory, and a multiplexed bus configuration with memory tristate waitstate (bit MTTCx = 0) is used, or b) the instruction preceeding the PWRDN instruction writes to external memory or an XPeripheral (e.g. CAN or XRAM), and the instructions following the PWRDN instruction are located in external memory. In this case, the problem will occur for any bus configuration. Note: The on-chip peripherals are still working correctly, in particular the Watchdog Timer will reset the device upon an overflow. Interrupts and PEC transfers, however, can not be processed. In case NMI is asserted low while the device is in this quasi-idle state, power down mode is entered. Workaround: Ensure that no instruction which writes to external memory or an XPeripheral preceeds the PWRDN instruction, otherwise insert e.g. a NOP instruction in front of PWRDN. When a muliplexed bus with memory tristate waitstate is used, the PWRDN instruction should be executed out of internal RAM. RST.13.1 Power Up with missing Clock While no clock is provided at XTAL1 and - RSTIN = High (while VDD ≤ 2V) or - power off/on recovery time is below 1 second (beginning from ≤ 0.3V at all pins) then following settings can be found: • The realtime clock registers are not cleared (T14, T14REL, RTCH, RTCL). • The slow down divider (SDD) can be selected as fCPU clock source (no oscillator watchdog function possible - the device will stop while external clock is missing) Workaround: None C164CI-8E, Step ES-CB, CB 18/30 es, V1.1, 2005-10-10 Errata Sheet Deviations from Electrical- and Timing Specification 3 Deviations from Electrical- and Timing Specification Problem Parameter Short Name Symbol Limit Values min. max. Unit Test Condition DC.HYS.11) Input Hysteresis HYS (Special Threshold) 300 1) instead of 400 – mV – DC.IOZ2.2 Input Leakage Current (Pin EA only) – ± 1000 instead of ±500 nA 0.45 V < VIN < VDD DC.VILS.12) Input low voltage VILS (Special Threshold) - 0.5 1.7 2) instead of 2.0 V – DC.VIH.1 Input high voltage (Pin EA only) VIH 0.7 VDD VDD + instead of 0.5 0.2 VDD + 0.9 V – AC.t48.1 RDCS#/WRCS# low time (with RWdelay) t48 38 + tc instead of 40 + tc ns – AC.t49.1 RDCS#/WRCS# low time (without RW-delay) t49 63+tc instead of 65 + tc ns – IOZ2 1) If fCPU ≤ 16 MHz the specified value is guaranteed by design. 2) For VDD > 4.4 V and fCPU ≤ 16 MHz the specified value is guaranteed by design. Note: Timing t28: Parameter description and test changed from 'Address hold after RD/ WR' to 'Address hold after WR'. It is guaranteed by design that read data are internally latched by the controller before the address changes. Note: During reset and adapt mode (in external bus mode - pin EA = LOW), the internal pull-ups on P4[3:0] are active, independent whether the respective pins are used for CS function after reset or not. C164CI-8E, Step ES-CB, CB 19/30 es, V1.1, 2005-10-10 Errata Sheet Application Hints 4 Application Hints SSC.H1 Handling of the SSC Busy Flag (SSCBSY) In master mode of the High-Speed Synchronous Serial Interface (SSC), when register SSCTB has been written, flag SSCBSY is set to '1' when the baud rate generator generates the next internal clock pulse. The maximum delay between the time SSCTB has been written and flag SSCBSY=1 is up to 1/2 bit time. SSCBSY is cleared 1/2 bit time after the last latching edge. When polling flag SSCBSY after SSCTB has been written, SSCBSY may not yet be set to '1' when it is tested for the first time (in particular at lower baud rates). Therefore, e.g. the following alternative methods are recommended: • test flag SSCRIR (receive interrupt request) instead of SSCBSY (in case the receive interrupt request is not serviced by CPU interrupt or PEC), e.g. loop: BCLR SSCRIR ;clear receive interrupt request flag MOV SSCTB, #xyz ;send character wait_tx_complete: JNB SSCRIR, wait_tx_complete ;test SSCRIR JB SSCBSY, wait_tx_complete ;test SSCBSY to achieve original ;timing (SSCRIR may be set 1/2 bit ; time before SSCBSY is cleared) • use a software semaphore bit which is set when SSCTB is written and is cleared in the SSC receive interrupt routine SSC.H2 Timing of flag SSCTIR (SSC Transmit Interrupt Request) In master mode, the timing of SSCTIR is as follows: When SSCTB has been written while the transmit shift register was empty (and the SSC is enabled), flag SSCTIR is set to '1' directly after completion of the write operation, independent of the selected baud rate. When the transmit shift register is not empty when SSCTB was written, SSCTIR is set to '1' after the last latching edge of SCLK (= 1/ 2 bit time before the first shifting edge of the next character). See also e.g. C167CR User's Manual V3.1, p. 12-5. The following diagram shows these relations in an example for a data transfer in master mode with SSCPO = 0 and SSCPH = 0. It is assumed that the transmit shift register is empty at the time the first character is written to SSCTB: C164CI-8E, Step ES-CB, CB 20/30 es, V1.1, 2005-10-10 Errata Sheet Application Hints write to SSCTB, first character write to SSCTB, next character SCLK MTSR Bit 0 Bit n Bit 1 SSCTIR = 1 SSCTIR = 1 Figure 2 Bit 0 SSCTB Timing Typically, in interrupt driven systems, no problems are expected from the modified timing of flag SSCTIR. However, when flag SSCTIR is polled by software in combination with other flags which are set/cleared at the end or at the beginning of a transfer (e.g. SSCBSY), the modified timing may have an effect. Another situation where a different system behaviour may be noticed is the case when only one character is transferred by the PEC into the transmit buffer register SSCTB. In this case, 2 interrupt requests from SSCTIR are expected: the 'PEC COUNT = 0' interrupt, and the 'SSCTB empty' interrupt: When the PEC transfer is performed with sufficient margin to the next clock tick from the SSC baud rate generator, and no higher priority interrupt request has occurred in the meantime, the 'PEC COUNT = 0' interrupt will be acknowledged before the 'SSCTB empty' interrupt request is generated, i.e. two interrupts will occur based on these events. However, when the PEC transfer takes place relatively close before the next clock tick from the SSC baud rate generator, or a higher priority interrupt request has occurred while the PEC transfer is performed, the 'PEC COUNT = 0' interrupt may not be acknowledged before the 'SSCTB empty' interrupt request is generated, such that effectively only one interrupt request will be generated for two different events. In order to achieve a defined and systematic behavior with all device steps, the SSC receive interrupt, which is generated at the end of a character transmission, may be used instead of the SSC transmit interrupt. C164CI-8E, Step ES-CB, CB 21/30 es, V1.1, 2005-10-10 Errata Sheet Application Hints CAN.H1 Note on Interrupt Register Behaviour of the CAN module Due to the internal state machine of the CAN module, a specific delay has to be considered between resetting INTPND and reading the updated value of INTID. See Application Note AP2924 "Interrupt Register behaviour of the CAN module ...". Follow the link: ’Application Notes - 16-bit Microcontrollers’ on the 16-bit microcontroller internet pages of Infineon Technologies: www.infineon.com/16-bit-microcontrollers EMUL.H1 Adapt Mode setting for emulation of devices in Single Chip Mode In Adapt Mode all target device pins are in high impedance state. This mode is mainly used for deactivation of the soldered device while an emulator probe is connected. In single chip mode (EA = 1) Adapt Mode can not be selected via PORT0 (P0L.1) during reset, because PORT0 is not evaluated in this mode. Recommendation: • use no target device or a dummy device (package without silicon on the PCB) for emuation or • use the target device on the PCB and: – provide a possibility to set target device pins EA and P0L.1 to "0" during reset (now the adapt mode is enabled on the target device) and – disconnect pin EA from the emulator probe and – set the EA pin on the emulator-probe to "1" to configure the emulator in single chip mode. OTP.H1 OTP Read access in CHM Mode delivers Zeros only In CHM mode the ROM-bus interface has no access to OTP (the OTP module is in a special mode for programming). In this mode the OTP contents can be checked by the verify sequence only. See e.g. C164CI User's Manual: Memory Organization - OTP Memory Programming - OTP Programming Example: "ALT_VERIFY". C164CI-8E, Step ES-CB, CB 22/30 es, V1.1, 2005-10-10 Errata Sheet Application Hints MainOsc.H1 Main Oscillator Type_LP2: Negative Resistance and Start-up Reliability Compared to other C16x microcontrollers the gain of the on-chip oscillator (Type_LP2) is slightly different. It is recommended to check the negative resistance and the start-up reliability of the oscillator circuit in the original application. Please refer to the limits specified by the quartz crystal or ceramic resonator supplier. See also Application Note AP2420 'Crystal Oscillator of the C500 and C166 Microcontroller Families' and Application Note AP2424 'Ceramic Resonator Oscillators of the C500 and C166 Microcontroller Families'. Follow the link: ’Application Notes - 16-bit Microcontrollers’ on the 16-bit microcontroller internet pages of Infineon Technologies: www.infineon.com/16-bit-microcontrollers MainOsc.H2 Maximum Oscillator Frequency = 16 MHz (Main: Type_LP2) The main oscillator is optimized for oscillation with a crystal within a frequency range of 4...16 MHz. When driven by an external clock signal it will accept the specified frequency range (see Data Sheet, AC Characteristics, tables ’Clock Generation Modes’ and ’External Clock Drive Characteristics’). Operation at lower input frequencies is possible but is guaranteed by design only (not 100% tested) (see Data Sheet, AC Characteristics, table ’External Clock Drive Characteristics’). OWD.H2 Oscillator Watchdog and Prescaler Mode The OWD replaces a missing oscillator clock signal with the PLL clock signal (base frequency). In direct drive mode the PLL base frequency is used directly (fCPU = 2...5 MHz). In prescaler mode the PLL base frequency is divided by 2 (fCPU = 1...2.5 MHz). C164CI-8E, Step ES-CB, CB 23/30 es, V1.1, 2005-10-10 Errata Sheet Application Hints ISNC.H1 Maintenance of ISNC register The RTC and PLL interrupts share one interrupt node (XP3IC). If an interrupt request occurs the request bit in the Interrupt Subnode Control register has to be checked and cleared by software. To avoid a collision with the next hardware interrupt request of same source it is recommended to clear the request and the enable bit first and then to set the enable bit again. Example for an XP3 interrupt service routine (for Tasking C compiler): ... if (PLLIR) { _bfld (ISNC, 0x000C, 0x0000); _putbit (1, ISNC, 3); ... } if (RTCIR) { _bfld (ISNC, 0x0003, 0x0000); _putbit (1, ISNC, 1); ... } ... // clear PLLIE and PLLIR // set PLLIE // further actions concerning PLL/OWD // clear RTCIE and RTCIR // set RTCIE // further actions concerning RTC Example for an XP3 interrupt service routine (in assembly language): ... EXTR JNB EXTR #1 PLLIR, no_pll_request #2 ; no further interruption of this ; sequence possible BFLDL ISNC, #0Ch, #00h ; clear PLLIE and PLLIR BSET PLLIE ; set PLLIE ... ; further actions concerning PLL/OWD no_pll_request: EXTR #1 JNB RTCIR, no_rtc_request EXTR #2 ; no further interruption of this sequence possible BFLDL ISNC, #03h, #00h ; clear RTCIE and RTCIR BSET RTCIE ; set RTCIE ... ; further actions concerning RTC no_rtc_request: ... C164CI-8E, Step ES-CB, CB 24/30 es, V1.1, 2005-10-10 Errata Sheet Documentation Update 5 Documentation Update INT.D1 Data Sheet V2.0, 2001-05 - Special Function Registers Overview In contrast to Table 7 (Data Sheet V2.0, page 33...) the following CCxIC registers are not implemented: CC20IC, CC21IC, CC22IC, CC23IC, CC28IC, CC29IC, CC30IC and CC31IC. See also Table 3 C164CI Interrupt Nodes (page 17). PORT.D2 Output Driver Control In contrast to the user’s manual in the C164CI-8E the registers POCONx are not available. The output drivers edge characteristic can be configured by register PDCR instead. Edge Characteristic This defines the rise/fall time for the respective output, i.e. the output transition time. Slow edges reduce the peak currents that are drawn when changing the voltage level of an external capacitive load. For a bus interface, however, fast edges may still be required. Edge characteristic effects the pre-driver which controls the final output driver stage. Open Drain control Edge control Push Data Signal Pull Control Signals Figure 3 Driver Control Logic Driver Stage Pin Structure of Output Driver with Edge Control C164CI-8E, Step ES-CB, CB 25/30 es, V1.1, 2005-10-10 Errata Sheet Documentation Update The Port Driver Control Register PDCR provides the corresponding control bits. A separate control bit is provided for bus pins as well as for non-bus pins. PDCR Port Driver Control Reg. ESFR (F0AAH/55H) Reset value: 0000H 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 - - - - - - - - - - - NBP EC - - - BIP EC - - - - - - - - - - - rw - - - rw Bit Function BIPEC Bus Interface Pins Edge Characteristic (Defines the outp. rise/fall time tRF) 0: Fast edge mode, rise/fall times depend on the driver’s dimensioning. 1: Reduced edge mode. BIPEC controls: PORT0, PORT1, Port 4, RD, WR, ALE, CLKOUT, BHE/WRH, RSTOUT, RSTIN (bidirectional reset mode only). NBPEC Non-Bus Pins Edge Characteristic (Defines the output rise/fall time tRF) 0: Fast edge mode, rise/fall times depend on the driver’s dimensioning. 1: Reduced edge mode. NBPEC controls: Port 3, Port 8 The figure below summarizes the effects of the driver characteristics: Edge characteristic generally influences the output signal’s shape. Fast Edge Figure 4 Slow Edge General Output Signal Waveforms C164CI-8E, Step ES-CB, CB 26/30 es, V1.1, 2005-10-10 Errata Sheet Documentation Update DOC_OTP.D1 Differences to Data Sheet Version 2.0, May 2001 To merge the documentation of all C164CI derivatives the Data Sheet Version 2.0, May 2001 will be used as the standard description. The following table describes the differences of the C164CI-8E Steps Cx to this document. Therefore, in conjunction with the described differences the Data Sheet V2.0 is valid for steps Cx, even though the Data Sheet refers to steps starting with DA. Table 5 Function Documentation Update Short Description Data Sheet V2.0, 2001-05 affected section Operating Frequency Standard operating frequency: 20 MHz. • overview All timings, baud rates, resolutions and • Functional ADC conversion time have to be Description recalculated • Serial Channels • Table 11 • Table 12 • AC Characteristics • CLKOUT page 1 11 26 51 54 58 ff 72 Extension RAM XRAM is not available in step C overview 1 CAN pin assignment CAN RxD and TxD are fixed assigned to Port 4 (P4.5 and P4.6), CAN Register IR is implemented instead of PCIR (no bitfield IPC) - see CAN.D1 • Figure 2 • Table 2 Pin Definitions and Functions • CAN-Module 4 10 27 CAN clock prescaler Clock Prescaler Control Bit CPS in CAN-Module register CSR is implented in step D 1st 27 OTP Programming voltage see OTP.8 Memory Organization 12 External Bus Controller Demultiplexed Bus Mode available (this mode was not described before) • Ext. Bus Controller • AC Characteristics 13 65 ff CAPCOM6 Version 3 implemented - see description below The Capture/ Compare Unit CAPCOM6 Watchdog Timer No input prescaler implemented Watchdog Timer only fCPU / 2 or fCPU / 128 available time interval 26 µs ... 422 ms @ 20 MHz default interval 6.55 ms @ 20 MHz C164CI-8E, Step ES-CB, CB 27/30 21 27 es, V1.1, 2005-10-10 Errata Sheet Documentation Update Table 5 Function Documentation Update (cont’d) Short Description Data Sheet V2.0, 2001-05 affected section page Frequency output The programmable frequency output FOUT is not available in step C • Parallel Ports • Power Management 28 30 Port Driver Port driver characteristics controlled by • Parallel Ports register PDCR (for 2 groups: ext. bus • Operating ports and others) instead of registers Conditions POCONx - see PORT.D2 (footnote 5) 28 42 Sleep Mode The sleep mode (and register SYSCON1) is not available in step C • overview • Power Management • Power Consumption 1 30 46 Digital supply voltage Minimum 4.5 V Operating Conditions 42 Ports Output low voltage VOL max = 0.45 V @ IOL = 2.4 mA (PORT0, PORT1, Port 4, ALE, RD, WR, BHE, CLKOUT, RSTOUT) DC Characteristics 43 Ports Output low voltage VOL1 max = 0.45 V @ IOL = 1.6 mA (all other outputs) DC Characteristics 43 Ports Output high voltage VOH min = 2.4 V @ IOH = -2.4 mA VOH min = 0.9 VDD @ IOH = -0.5 mA (PORT0, PORT1, Port 4, ALE, RD, WR, BHE, CLKOUT, RSTOUT) DC Characteristics 43 Ports Output high voltage VOH1 min = 2.4 V @ IOH = -1.6 mA VOH1 min = 0.9 VDD @ IOH = -0.25 mA (all other outputs) DC Characteristics 43 RSTIN inactive / active current To meet the real test condition the pullup resistor definition is replaced by "RSTIN inactive current" and "RSTIN active current" DC Characteristics footnote 6 44 C164CI-8E, Step ES-CB, CB 28/30 es, V1.1, 2005-10-10 Errata Sheet Documentation Update Table 5 Function Documentation Update (cont’d) Short Description Data Sheet V2.0, 2001-05 affected section page Port drivers The pin drivers have a fixed DC Characteristics configuration (control register PDCR is Table 10 (Current implemented instead of POCONx) Limits for Port Output Drivers) 45 Power Consumption Power-down mode supply current with RTC running: IPDR = 200 + 25 * fOSC see DC.IPDR.2 Power Consumption 46 External Clock Drive Characteristics 54 External Clock Minimum Oscillator Period: • Direct Drive: 50 ns • Prescaler 2:1: 25 ns • PLL 1:N: 75 ns Minimum high time t1 = 181) ns Minimum low time t2 = 181) ns 1) The minimum high and low time refers to a duty cycle of 50%. The maximum operating freqency (fCPU) in direct drive mode depends on the duty cycle of the clock input signal. CAPCOM6 Version 3 • The Block Commutation sequence table for left rotation is not a standard commutation table, but rather is shifted against the standard pattern by 60 degrees. • Cout63 is switched to P1L.6 while CTRAP = low. • In case of a trap event (CTRAP = low) CAPCOM6 outputs are not switched to their initial values (CC6MCON, bits 0..5 and bit 7), but to port register P1L instead. • switches TT12DIS and TT13DIS are not available For more details see application note AP1673: Technical details on CAPCOM6 module C164CI-8E, Step ES-CB, CB 29/30 es, V1.1, 2005-10-10 Errata Sheet Documentation Update ID-Registers Register: IDMANUF IDCHIP IDMEM IDPROG IDMEM2 Device Step Address: F07EH F07CH F07AH F078H F076H C164CI-8E -CA 1820H 0A03H 4010H 9340H 0000H C164SI-8E -CA 1820H 1B03H 4010H 9340H 0000H C164CI-8E -CB 1820H 0A06H 4010H 9340H 0000H C164SI-8E -CB 1820H 1B06H 4010H 9340H 0000H Product and Test Engineering Group, Munich C164CI-8E, Step ES-CB, CB 30/30 es, V1.1, 2005-10-10