Errata Sheet V1.1, 2005-04-07 Device C164CI-8E Marking/Step Step ES-DB, DB Package P-MQFP-80 This Errata Sheet describes the deviations from the current user documentation. The module oriented classification and numbering system uses an ascending sequence over several derivatives, including already solved deviations. So gaps inside this enumeration can occur. Current Documentation • C164CI/CL, SI/SL Data Sheet, V2.0, May 2001 • C164CI/CL, SI/SL User’s Manual, V3.1, Feb. 2002 • Instruction Set Manual, V2.0, Mar. 2001 Note: Devices marked with EES- or ES are engineering samples which may not be completely tested in all functional and electrical characteristics, therefore they should be used for evaluation only. The specific test conditions for EES and ES are documented in a separate Status Sheet. Contents Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page History List/Change Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Functional Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Deviations from Electrical- and Timing Specification. . . . . . . . . . . . . . . . . . . . . . .16 Application Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Documentation Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 C164CI-8E, Step ES-DB, DB 1/28 es, V1.1, 2005-04-07 Errata Sheet History List/Change Summary 1 History List/Change Summary (from step ES-BB, previous errata sheet V1.0, step: DB) Table 1 Functional Deviations Functional Problem Short Description ADC.11 Modifications of ADM field while bit ADST = 0 SSC.9 Data Transmission in Slave Mode CAN.7 Unexpected Remote Frame Transmission CAN.9 Contents of Message Objects and Mask of Last Message Registers after Reset Fixed Change in step new CAPCOM.2 Wakeup from Idle Mode by CAPCOM2 channels CC19 or CC27 CA CAPCOM6.3 Write Access to CAPCOM6 Registers CA CAPCOM6.4 Spike when enabling alternate Port Function RTC.2 Read RTC count registers CA RTC.4 Undefined Results after write to T14 DA TCOMP.3 Pad Driver Temperature Compensation disabled (see also Documentation Update TCOMP.D2) DA BUS.17 Spikes on CS lines after access with RDCS and/or WRCS DA BUS.18 PEC transfers after JMPR DA X9 Read Access to XPERs in Visible Mode OTP.7 Verify in CHM when Bootstrap Loader Mode is selected OTP.8 CPU.16 Programming Voltage VPP and Supply Voltage VDD Data read access with MOVB [Rn], mem instruction to internal ROM/Flash/OTP DA CPU.17 Arithmetic Overflow by DIVLU instruction DA CPU.21 BFLDL/BFLDH Instructions after Write Operation to internal IRAM DA CPU.22 Z Flag after PUSH and PCALL PLL.3.1 Increased PLL Jitter caused by external Access PWRDN.1 Execution of PWRDN instruction while Pin NMI = high C164CI-8E, Step ES-DB, DB 2/28 CA DA es, V1.1, 2005-04-07 Errata Sheet History List/Change Summary Table 1 Functional Deviations (cont’d) Functional Problem Short Description Fixed Change in step POWER.22 Wake up from Sleep Mode in Oscillator Decay Time new RST.4 Power on Reset CA ADP.1 Oscillator in Adapt Mode CA Table 2 AC/DC Deviations AC/DC Deviations Short Description DC.AH.2 ALE active current 650 µA DC.HYS.1 Input Hysteresis (Special Threshold) 300 mV DC.IOZ2.2 Input Leakage Current IOZ2 +/- 1 µA (Pin EA only) DC.P0L.2 P0 configuration current -120 µA CA DC.P4L.2 P4 active current -650 µA CA DC.RL.2 RD/WR active current -650 µA CA DC.VDD.1 Device Supply Voltage VDD min. 4.4 V DA DC.VDD.3 see Documentation Update (VDD.D1) DC.VILS.1 Input low voltage (Special Threshold) 1.7 V DC.VIH.1 Input high voltage VIH_min on P20.5 / EA AC.PLL.1 PLL Base Frequency 2...6 MHz (instead of 2...5) AC.t34.n4 CLKOUT rising edge to ALE falling edge min -4ns AC.t48.1 RDCS/WRCS low time (with RW-delay) 2TCL-12ns DA AC.t49.1 RDCS/WRCS low time (no RW-delay) 3TCL-12ns DA C164CI-8E, Step ES-DB, DB Fixed Change in step CA 3/28 es, V1.1, 2005-04-07 Errata Sheet History List/Change Summary Table 3 Application Hints Hint Short Description SSC.H1 Handling of the SSC Busy Flag (SSCBSY) SSC.H2 Timing of flag SSCTIR (SSC Transmit Interrupt Request) CAN.H1 Note on Interrupt Register behaviour of the CAN module Change CAPCOM6.H1 Improvements of Capture/Compare Unit CAPCOM6 EMUL.H1 Adapt Mode Setting OTP.H1 OTP Read access in CHM Mode delivers Zeros only BSL.H1 Bootstrap Loader: Baudrate Detection in Single Chip Boot Mode MainOsc.H1 Oscillator Type_LP2: Negative Resistance and Start-up Reliability MainOsc.H2 Maximum (Type_LP2) Oscillator Frequency = 16 MHz OWD.H2 Oscillator Watchdog and Prescaler Mode ISNC.H1 Maintenance of ISNC Register C164CI-8E - Step DA Enhancements Table 4 Documentation Update Name Short Description Change New User’s Manual available: C164CI/CL, SI/SL User’s Manual, V3.1, Feb. 2002 New Data Sheet available: C164CI/CL, SI/SL Data Sheet, V2.0, May 2001 TCOMP.D2 Temperature Compensation redesigned PORT.D3 P3.15 and Frequency Output Signal Path INT.D1 CCxIC Registers PLL.D1 PLL goes to Unlocked State after Configuration VDD.D1 Data Sheet V2.0, 2001-05 - Operating Conditions new ID-Registers ID-Registers C164CI-8E, Step ES-DB, DB 4/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems 2 Functional Problems ADC.11 Modifications of ADM field while bit ADST = 0 The A/D converter may unintentionally start one auto scan single conversion sequence when the following sequence of conditions is true: 1. the A/D converter has finished a fixed channel single conversion of an analog channel n > 0 (i.e. contents of ADCON.ADCH = n during this conversion) 2. the A/D converter is idle (i.e. ADBSY = 0) 3. then the conversion mode in the ADC Mode Selection field ADM is changed to Auto Scan Single (ADM = 10b) or Continuous (ADM = 11b) mode without setting bit ADST = 1 with the same instruction Under these conditions, the A/D converter will unintentionally start one auto scan single conversion sequence, beginning with channel n-1, down to channel number 0. When no interrupt or PEC is servicing the A/D Conversion Complete Interrupt, interrupt request flag ADCIR will be set, and for n > 1 also the A/D Overrun Error interrupt request flag will be set, unless the wait for ADDAT read mode had been selected. When ADCON.ADWR = 1 (wait for ADDAT read), the converter will wait after 2 conversions until ADDAT is read. In case the channel number ADCH has been changed before or with the same instruction which selected the auto scan mode, this channel number has no effect on the unintended auto scan sequence (i.e. it is not used in this auto scan sequence). Note: When a conversion is already in progress, and then the configuration in register ADCON is changed, • the new conversion mode in ADM is evaluated after the current conversion • the new channel number in ADCH and new status of bit ADST are evaluated after the current conversion when a conversion in fixed channel conversion mode is in progress, and after the current conversion sequence (i.e. after conversion of channel 0) when a conversion in an auto scan mode is in progress. In this case, it is a specified operational behaviour that channels n-1 .. 0 are converted when ADM is changed to an auto scan mode while a fixed channel conversion of channel n is in progress (see e.g. C164CI User's Manual, V1.0, p.18-4) Workaround: When an auto scan conversion is to be performed, always start the A/D converter with the same instruction which sets the configuration in register ADCON. C164CI-8E, Step ES-DB, DB 5/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems SSC.9 Data Transmission in Slave Mode During data reception in slave mode of the SSC module, sporadically the shift clock supplied by the external master on pin SCLK may not be properly recognized due to a synchronization problem when all of the following conditions are true: 1. the latching edge for the serial data is the falling edge of SCLK (i.e. both bit SSCPO = 1 and bit SSCPH = 1, or SSCPO = 0 and SSCPH = 0 in register SSCCON), and 2. the transmit buffer SSCTB of the slave has not been written prior to the start of the reception (initiated by the master asserting the shift clock SCLK), and 3. a specific time window (phase delay) is hit by the serial shift clock SCLK in relation to the internal system clock of the slave. Therefore, this synchronization problem will occur in particular when the slave device is clocked (on XTAL1) by an external clock generation circuit which is independent from the clock generation circuit of the master (i.e. slave and master clocks are asynchronous). When the problem occurs, this results in missing bits in the character received in SSCTB, and in duplicated bits in the character transmitted on pin MRST of the slave. As a consequence, interrupt generation in the slave is delayed by the number of missed bits. Workaround For systems using the falling edge of SCLK as latching edge (see condition 1. above), always write to the transmit buffer SSCTB prior to any reception in slave mode of the SSC module. For the second and all following characters, e.g. write a (dummy) character to SSCTB in the receive interrupt routine, or use a PEC transfer triggered by the transmit interrupt request to write to SSCTB. In this case, the critical synchronization path is not used, and the problem will not occur. CAN.7 Unexpected Remote Frame Transmission Symptom: The on-chip CAN module may send an unexpected remote frame with the identifier = 0, when a pending transmit request of a message object is disabled by software. Detailed Description: There are three possibilities to disable a pending transmit request of a message object (n = 1..14): • Set CPUUPDn element • Reset TXRQn element C164CI-8E, Step ES-DB, DB 6/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems • Reset MSGVALn element Either of these actions will prevent further transmissions of message object n. The symptom described above occurs when the CPU accesses CPUUPD, TXRQ or MSGVAL, while the pending transmit request of the corresponding message object is transferred to the CAN state machine (just before start of frame transmission). At this particular time the transmit request is transferred to the CAN state machine before the CPU prevents transmission. In this case the transmit request is still accepted from the CAN state machine. However the transfer of the identifier, the data length code and the data of the corresponding message object is prevented. Then the pre-charge values of the internal "hidden buffer" are transmitted instead, this causes to a remote frame transmission with identifier = 0 (11 bit) and data length code = 0. This behavior occurs only when the transmit request of message object n is pending and the transmit requests of other message objects are not active (single transmit request). If this remote frame loses arbitration (to a data frame with identifier = 0) or if it is disturbed by an error frame, it is not retransmitted. Effects to other CAN nodes in the network: The effect leads to delays of other pending messages in the CAN network due to the high priority of the Remote Frame. Furthermore the unexpected remote frame can trigger other data frames depending on the CAN node's configuration. Workarounds: • The behavior can be avoided if a message object is not updated by software when a transmission of the corresponding message object is pending (TXRQ element is set) and the CAN module is active (INIT = 0). If a re-transmission of a message (e.g. after lost arbitration or after the occurrence of an error frame) needs to be cancelled, the TXRQ element should be cleared by software as soon as NEWDAT is reset from the CAN module. • The nodes in the CAN system ignore the remote frame with the identifier = 0 and no data frame is triggered by this remote frame. CAN.9 Contents of Message Objects and Mask of Last Message Registers after Reset After any reset, the contents of the CAN Message Objects and the Mask of Last Message Registers may be undefined instead of unaffected (reset value 'X' instead of 'U'). C164CI-8E, Step ES-DB, DB 7/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems This problem depends on temperature and the length of the reset, and differs from device to device. The problem is more likely to occur at high temperature and for long hardware resets (> 100 ms). Workaround: Re-initialize the CAN module after each reset. CAPCOM6.4 Spike when enabling alternate Port Function When switching a port from I/O mode to compare mode during the low state of the PWM by setting bits in register CC6MSEL, a spike is generated for one TCL before the PMW signal starts. Workaround: When the port configuration is changed during the high phase of the compare output the spike is suppressed. Two different interrupts can be used for this synchronization depending on the initial value bits in the register CC6MCON (CCxI and COUTxI represent the passive output level for the enabled compare channels). The first high phase of the PWM signal is delayed by the corresponding interrupt latency and the execution time of the necessary instructions: • If the initial value is 0, the compare interrupt service routine switches the port to compare output. So the spike is pushed in the high phase of the PWM. • If the initial value is 1, the Timer 12 period match interrupt service routine switches the port to compare mode with the same result. X9 Read Access to XPERs in Visible Mode The data of a read access to an XBUS-Peripheral (CAN) in Visible Mode (SYSCON.1 = 1) is not driven to the external bus. PORT0 is tristated during such read accesses. Note that in Visible Mode PORT1 will drive the address for an access to an XBUSPeripheral, even when only a multiplexed external bus is enabled. C164CI-8E, Step ES-DB, DB 8/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems OTP.8 Programming Voltage V PP and Supply Voltage VDD To guarantee a proper internal OTP programming the tolerances for supply voltage VDD and programming voltage VPP are reduced. The following values have been successfully tested and can be recommended: Supply Voltage VDD 4.35V - 4.65V Programming Voltage VPP 11.35V - 11.65V 4.85V - 5.15V 11.8V - 12.1V Application Hints: • Devices formerly programmed with these recommended values can be used without restriction. • Software for OTP programming tools should be adapted to one of these recommended values (VDD = 4.85V - 5.15V and VPP = 11.8 - 12.1V can still be used after the problem is fixed in the future). CPU.22 Z Flag after PUSH and PCALL The Z flag in the PSW is erroneously set to '1' by PUSH reg or PCALL reg, rel instructions when all of the following conditions are true: a) for PUSH reg instructions: • the contents of the high byte of the GPR or (E)SFR which is pushed is 00H, and • the contents of the low byte of the GPR or (E)SFR which is pushed is > 00H, and • the contents of GPR Rx is odd, where x = 4 msbs of the 8-bit 'reg' address of the pushed GPR or (E)SFR Examples: PUSH PUSH R1 ;(coding: F1 ; incorrect ; and 00FFh DPP3 ;(coding: 03 ; incorrect ; and 00FFh EC): setting of ≥ contents EC): setting of ≥ contents Z flag if contents of R15 is odd, of R1 ≥ 0001h Z flag if contents of R0 is odd, of DPP3 ≥ 0001h b) for PCALL reg, rel instructions: • when the contents of the high byte of the GPR or SFR which is pushed is 00H, and • when the contents of the low byte of the GPR or SFR which is pushed is odd C164CI-8E, Step ES-DB, DB 9/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems This may lead to wrong results of instructions following PUSH or PCALL if those instructions explicitly (e.g. BMOV .. , Z; JB Z, ..; ..) or implicitly (e.g. JMP cc_Z, ..; JMP cc_NET, ..; ..) evaluate the status of the Z flag before it is newly updated. Note: Some instructions (e.g. CALL, ..) have no effect on the status flags, such that the status of the Z flag remains incorrect after a PUSH/PCALL instruction until an instruction that correctly updates the Z flag is executed. Example: PUSH R1 CALL proc_xyz ... ... proc_xyz: JMP cc_Z,end_xyz ... end_xyz: ; incorrect setting of Z flag if R15 is odd ; Z flag remains unchanged ; (is a parameter for proc_xyz) ; Z flag evaluated with incorrect setting Effect on Tools: • The Hightec C166 tools (all versions) don't use the combination of PUSH/PCALL and the evaluation of the Z flag. Therefore, these tools are not affected. • The code generated by the Keil C166 Compiler evaluates the Z flag only after MOV, CMP, arithmetic, or logical instructions. It is never evaluated after a PUSH instruction. PCALL instructions are not generated by the C166 Compiler. This has been checked with all C166 V3.xx and V4.xx compiler versions. Even the upcoming V5.xx is not affected by the CPU.22 problem. The assembler portions of the C166 V3.xx and V4.xx Run-Time Libraries, the RTX166 Full and TX166 Tiny Real Time Operating system do also not contain any evaluation of the Z flag after PUSH or PCALL. • The TASKING compiler V7.5r2 never generates a PCALL instruction, nor is it used in the libraries. The PUSH instruction is only used in the entry of an interrupt frame, and sometimes on exit of normal functions. The zero flag is not a parameter or return value, so this does not give any problems. C164CI-8E, Step ES-DB, DB 10/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems Previous versions of TASKING tools: V3.x and higher are not affected, versions before 3.x are most likely not affected. Contact TASKING when using versions before V3.x. Since code generated by the C166 compiler versions mentioned before is not affected, analysis and workarounds are only required for program parts written in assembler, or instruction sequences inserted via inline assembly. Workaround (for program parts written in assembler): Do not evaluate the status of the Z flag generated by a PUSH or PCALL instruction. Instead, insert an instruction that correctly updates the PSW flags, e.g. PUSH CMP JMPR reg reg, #0 ; note: ; CMP additionally modifies the C and V flags, ; while PUSH or MOV leaves them unaffected cc_Z, label_1; implicitly tests Z flag or PCALL reg, procedure_1 ... procedure_1: MOV ONES, reg JMPR cc_NET, label_1 ; implicitly tests flags Z and E Hints for Detection of Critical Instruction Combinations Whether or not an instruction following PUSH reg or PCALL reg, rel actually causes a problem depends on the program context. In most cases, it will be sufficient to just analyze the instruction following PUSH or PCALL. In case of PCALL, this is the instruction at the call target address. Support Tool for Analysis of Hex Files For complex software projects, where a large number of assembler source (or list) files would have to be analyzed, Infineon provides a tool aiScan22 which scans hex files for critical instruction sequences and outputs diagnostic information. This tool is available as part of the Application Note ap1679 'Scanning for Problem CPU.22' on the 16-bit microcontroller internet pages of Infineon Technologies: www.infineon.com/16-bit-microcontrollers C164CI-8E, Step ES-DB, DB 11/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems direct links: AP1679 Description: www.infineon.com/cmc_upload/documents/040/841/ ap1679_v1.1_2002_05_scanning_cpu22.pdf and AP1679 Software: www.infineon.com/cgi/ecrm.dll/ecrm/scripts/ public_download.jsp?oid=40840&parent_oid=-8984 Individual Analysis of Assembler Source Code With respect to problem CPU.22, all instructions of the C166 instruction set can be classified into the following groups: • Arithmetic/logic/data movement instructions as successors of PUSH/PCALL (correctly) modify the condition flags in the PSW according to the result of the operation. These instructions may only cause a problem if the PSW is a source or source/ destination operand: ADD/B, ADDC/B, CMP/B, CMPD1/2, CMPI1/2, SUB/B, SUBC/B AND/B, OR/B, XOR/B ASHR MOV/B, MOVBZ/MOVBS SCXT PUSH, PCALL ! analysis must be repeated for successor of PUSH/PCALL • The following instructions (most of them with immediate or register (Rx) addressing modes) can never cause a problem: CPL/B, NEG/B DIV/U, DIVL/U, MUL/U SHL/SHR, ROL/ROR PRIOR POP RETI ! updates complete PSW with stacked value RETP ! updates condition flags PWRDN ! program restarts after reset SRST ! program restarts • Conditional branch instructions which may evaluate the Z flag: JB/JNB Z, rel ; directly evaluates Z flag CALLA/CALLI, JMPA/JMPI/JMPR with the following condition codes cc_Z, cc_EQ, cc_NZ, cc_NE cc_ULE, cc_UGT, cc_SLE, cc_SGT cc_NET C164CI-8E, Step ES-DB, DB 12/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems ! For these branch conditions, the branch may be performed in the wrong way. ! For other branch conditions, the branch target as well as the linear successor of the branch instruction must be analyzed (since these branch instruction don't modify the PSW flags). • For instructions that have no effect on the condition flags and that don't evaluate the Z flag, the instruction that follows this instruction must be analyzed. These instructions are: NOP ATOMIC, EXTxx DISWDT, EINIT, IDLE, SRVWDT CALLR, CALLS, JMPS ! branch target must be analyzed RET, RETS ! return target must be analyzed (value pushed by PUSH/PCALL = return IP, Z flag contains information whether intra-segment target address = 0000H or not) TRAP ! both trap target and linear successor must be analyzed, since Z flag may be incorrect in PSW on stack as well as in PSW at entry of trap routine • For bit modification instructions, the problem may only occur if a source bit is the Z flag, and/or the destination bit is in the PSW, but not the Z flag. These instructions are: BMOV/BMOVN BAND/BOR/BXOR BCMP BFLDH BFLDL ! problem only if bit 3 of @@ mask = 0, i.e. if Z is not selected BCLR/BSET ! problem only if operand is not Z flag JBC/JNBS ! wrong branch if operand is Z flag PWRDN.1 Execution of PWRDN Instruction while pin NMI = high When instruction PWRDN is executed while pin NMI is at a high level, power down mode should not be entered, and the PWRDN instruction should be ignored. However, under the conditions described below, the PWRDN instruction may not be ignored, and no further instructions are fetched from external memory, i.e. the CPU is in a quasi-idle state. This problem will only occur in the following situations: a) the instructions following the PWRDN instruction are located in external memory, and a multiplexed bus configuration with memory tristate waitstate (bit MTTCx = 0) is used, or b) the instruction preceeding the PWRDN instruction writes to external memory or an XPeripheral (e.g. CAN or XRAM), and the instructions following the PWRDN instruction C164CI-8E, Step ES-DB, DB 13/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems are located in external memory. In this case, the problem will occur for any bus configuration. Note: The on-chip peripherals are still working correctly, in particular the Watchdog Timer will reset the device upon an overflow. Interrupts and PEC transfers, however, can not be processed. In case NMI is asserted low while the device is in this quasi-idle state, power down mode is entered. Workaround: Ensure that no instruction which writes to external memory or an XPeripheral preceeds the PWRDN instruction, otherwise insert e.g. a NOP instruction in front of PWRDN. When a muliplexed bus with memory tristate waitstate is used, the PWRDN instruction should be executed out of internal RAM. POWER.22 Wake up from Sleep Mode in Oscillator Decay Time ran do m wa ke sl e up ep mo de e ke up leep m od tOSC mode fro m sleep random wa random wake tDECAY from s up fr om sl eep mo de Due to a synchronization problem, the device may not correctly wake up from sleep mode if an asynchronous external wake up trigger occurs already in the oscillator decay time, i.e. in a particular time window before the device has actually entered sleep mode (see figure) VIH threshold cyclic wake up from sleep mode VIL threshold Entry into sleep mode Figure 1 tCRIT Critical Event This problem may occur when all of the following conditions are met at the same time: 1. the device is configured for sleep mode with the following settings where the main oscillator (input XTAL1) will be switched off, i.e. a) with RTC and oscillator to be stopped (SYSCON1 bitfield SLEEPCON = 11B), or b) only for devices with XTAL3 input: with RTC running and supplied by the clock from XTAL3 (SYSCON1 bitfield SLEEPCON = 01B and SYSCON2 bit RCS = 1) C164CI-8E, Step ES-DB, DB 14/28 es, V1.1, 2005-04-07 Errata Sheet Functional Problems 2. the IDLE instruction to enter sleep mode has been executed, i.e. the main oscillator is in the oscillator decay time (typically ~ 160 µs decay time for a 16 MHz crystal, ~ 2 µs for a 16 MHz ceramic resonator) 3. the external wake up trigger signal (fast external interrupt or signal on pin NMI) coincides with the critical time window (tCRIT) of each oscillator cycle during the decay time of the clock signal at pin XTAL1 (critical times shown in red in figure) In this case the clock system may get blocked but the internal program memory module becomes enabled. IDDI rises up to IPDR ... 3 mA with main oscillator. The watchdog timer - stopped in sleep mode - cannot restart the system. Only HW reset restarts the system properly. The problem occurs only in the decay time of the main oscillator and in a very small window around the clock edge at XTAL1 (tCRIT is about 5 ps wide). The following formula shows a risk calculation for an asynchronous (random) wake up event at any time within a 100 ms sleep period (16 MHz crystal/resonator): PLock-Up = PSensitive Device* PCritical Wake-Up-Event PLock-Up = 5 ps (critical window) / 62500 ps (one 16 MHz oscillator period) * 160 µs (typical crystal decay time) / 100000 µs (wake up after 100 ms) PLock-Up = 5 / 62500 * 160 / 100000 = 0.000'000'13 = 0.13 failure events per 1 million random wake up events (for a 16 MHz crystal) The decay time of a resonator circuit is below 2 µs typically: PLock-Up (resonator) = 5 / 62500 * 2 / 100000 = 0.000'000'001’6 = 0.0016 failure events per 1 million random wake up events (for a 16 MHz resonator) Note: A cyclic wake up event would never cause the problem as it happens well after entry into sleep mode and after the decay time. Workarounds: • Select RTC on in sleep mode (SYSCON1.SLEEPCON = 01B). For devices with auxiliary oscillator (e.g. C161CS), select main oscillator as clock source (SYSCON2.RCS = 0). • Avoid a wake up during the main oscillator decay time C164CI-8E, Step ES-DB, DB 15/28 es, V1.1, 2005-04-07 Errata Sheet Deviations from Electrical- and Timing Specification 3 Deviations from Electrical- and Timing Specification Problem Parameter Short Name Symbol Limit Values min. max. Unit Test Condition DC.HYS.11) Input Hysteresis HYS (Special Threshold) 300 1) instead of 400 – mV – DC.IOZ2.2 Input Leakage Current (Pin EA only) – +/- 1000 instead of ±500 nA 0.45 V < VIN < VDD DC.VILS.11) Input low voltage VILS (Special Threshold) - 0.5 1.7 1) instead of 2.0 V – DC.VIH.1 Input high voltage (Pin EA only) VIH 0.7 VDD VDD + instead of 0.5 0.2 VDD + 0.9 V – AC.t34.n4 CLKOUT rising edge to ALE falling edge t34 -4 + tA instead of 0 + tA ns – AC.PLL.1 Pll base frequency - 2...6 MHz instead of see User's 2...5 MHz Manual: "Clock Generation" "PLL Operation" IOZ2 10 + tA 1) If fCPU ≤ 16 MHz the specified value is guaranteed by design. Note: Timing t28: Parameter description and test changed from 'Address hold after RD/ WR' to 'Address hold after WR'. It is guaranteed by design that read data are internally latched by the controller before the address changes. Note: During reset and adapt mode (in external bus mode - pin EA = LOW), the internal pull-ups on P4[3:0] are active, independent whether the respective pins are used for CS function after reset or not. C164CI-8E, Step ES-DB, DB 16/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints 4 Application Hints SSC.H1 Handling of the SSC Busy Flag (SSCBSY) In master mode of the High-Speed Synchronous Serial Interface (SSC), when register SSCTB has been written, flag SSCBSY is set to '1' when the baud rate generator generates the next internal clock pulse. The maximum delay between the time SSCTB has been written and flag SSCBSY=1 is up to 1/2 bit time. SSCBSY is cleared 1/2 bit time after the last latching edge. When polling flag SSCBSY after SSCTB has been written, SSCBSY may not yet be set to '1' when it is tested for the first time (in particular at lower baud rates). Therefore, e.g. the following alternative methods are recommended: • test flag SSCRIR (receive interrupt request) instead of SSCBSY (in case the receive interrupt request is not serviced by CPU interrupt or PEC), e.g. loop: BCLR SSCRIR ;clear receive interrupt request flag MOV SSCTB, #xyz ;send character wait_tx_complete: JNB SSCRIR, wait_tx_complete ;test SSCRIR JB SSCBSY, wait_tx_complete ;test SSCBSY to achieve original ;timing (SSCRIR may be set 1/2 bit ;time before SSCBSY is cleared) • use a software semaphore bit which is set when SSCTB is written and is cleared in the SSC receive interrupt routine SSC.H2 Timing of flag SSCTIR (SSC Transmit Interrupt Request) In master mode, the timing of SSCTIR is as follows: When SSCTB has been written while the transmit shift register was empty (and the SSC is enabled), flag SSCTIR is set to '1' directly after completion of the write operation, independent of the selected baud rate. When the transmit shift register is not empty when SSCTB was written, SSCTIR is set to '1' after the last latching edge of SCLK (= 1/ 2 bit time before the first shifting edge of the next character). See also e.g. C167CR User's Manual V3.1, p. 12-5. The following diagram shows these relations in an example for a data transfer in master mode with SSCPO = 0 and SSCPH = 0. It is assumed that the transmit shift register is empty at the time the first character is written to SSCTB: C164CI-8E, Step ES-DB, DB 17/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints write to SSCTB, first character write to SSCTB, next character SCLK Bit 0 Bit n Bit 1 Bit 0 MTSR SSCTIR = 1 SSCTIR = 1 Figure 2 SSCTB Timing Typically, in interrupt driven systems, no problems are expected from the modified timing of flag SSCTIR. However, when flag SSCTIR is polled by software in combination with other flags which are set/cleared at the end or at the beginning of a transfer (e.g. SSCBSY), the modified timing may have an effect. Another situation where a different system behaviour may be noticed is the case when only one character is transferred by the PEC into the transmit buffer register SSCTB. In this case, 2 interrupt requests from SSCTIR are expected: the 'PEC COUNT = 0' interrupt, and the 'SSCTB empty' interrupt: When the PEC transfer is performed with sufficient margin to the next clock tick from the SSC baud rate generator, and no higher priority interrupt request has occurred in the meantime, the 'PEC COUNT = 0' interrupt will be acknowledged before the 'SSCTB empty' interrupt request is generated, i.e. two interrupts will occur based on these events. However, when the PEC transfer takes place relatively close before the next clock tick from the SSC baud rate generator, or a higher priority interrupt request has occurred while the PEC transfer is performed, the 'PEC COUNT = 0' interrupt may not be acknowledged before the 'SSCTB empty' interrupt request is generated, such that effectively only one interrupt request will be generated for two different events. In order to achieve a defined and systematic behavior with all device steps, the SSC receive interrupt, which is generated at the end of a character transmission, may be used instead of the SSC transmit interrupt. C164CI-8E, Step ES-DB, DB 18/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints CAN.H1 Note on Interrupt Register Behaviour of the CAN module Due to the internal state machine of the CAN module, a specific delay has to be considered between resetting INTPND and reading the updated value of INTID. See Application Note AP2924 "Interrupt Register behaviour of the CAN module ..." on: Infineon Microcontroller Products: www.infineon.com/microcontrollers AP 2924 V01: http://www.infineon.com/cgi/ecrm.dll/ecrm/scripts/ public_download.jsp?oid=10042&parent_oid=-8984 CAPCOM6.H1 Improvements of Capture/Compare Unit CAPCOM6 From step Dx a new version of module CAPCOM6 has been implemented. The improvements are described in AP1673 “Technical details on CAPCOM6 module C164 family”. See: Infineon Microcontroller Products: www.infineon.com/microcontrollers AP1673: http://www.infineon.com/cmc_upload/documents/042/818/ap1607310_.pdf EMUL.H1 Adapt Mode setting for emulation of devices in Single Chip Mode In Adapt Mode all target device pins are in high impedance state. This mode is mainly used for deactivation of the soldered device while an emulator probe is connected. In single chip mode (EA = 1) Adapt Mode can not be selected via PORT0 (P0L.1) during reset, because PORT0 is not evaluated in this mode. Recommendation: • use no target device or a dummy device (package without silicon on the PCB) for emuation or • use the target device on the PCB and: – provide a possibility to set target device pins EA and P0L.1 to "0" during reset (now the adapt mode is enabled on the target device) and – disconnect pin EA from the emulator probe and – set the EA pin on the emulator-probe to "1" to configure the emulator in single chip mode. C164CI-8E, Step ES-DB, DB 19/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints OTP.H1 OTP Read access in CHM Mode delivers Zeros only In CHM mode the ROM-bus interface has no access to OTP (the OTP module is in a special mode for programming). In this mode the OTP contents can be checked by the verify sequence only. See e.g. C164CI User's Manual: Memory Organization - OTP Memory Programming - OTP Programming Example: "ALT_VERIFY". BSL.H1 Bootstrap Loader: Baudrate Detection in Single Chip Boot Mode In single chip boot mode (Pin EA = 1) the bootstrap loader mode is detected during hardware reset when pin RD is tied to low. In this mode fCPU = fOSC / 2 (default configuration) and can be controlled via register RSTCON. In case of a desired PLL mode (e.g. with a PLL factor of 5), fCPU in bootstrap loader mode is 10 times slower than in normal running mode. So a communication with an external host starts with a baudrate related to fCPU = fOSC / 2. It is recommended to establish a 2nd level loader which adapts fCPU and baudrate to a convenient transmission rate. MainOsc.H1 Main Oscillator Type_LP2: Negative Resistance and Start-up Reliability Compared to other C16x microcontrollers the gain of the on-chip oscillator (Type_LP2) is slightly different. It is recommended to check the negative resistance and the start-up reliability of the oscillator circuit in the original application. Please refer to the limits specified by the quartz crystal or ceramic resonator supplier. See also Application Note AP2420 'Crystal Oscillator of the C500 and C166 Microcontroller Families' and Application Note AP2424 'Ceramic Resonator Oscillators of the C500 and C166 Microcontroller Families'. Infineon Microcontroller Products: www.infineon.com/microcontrollers AP2420: www.infineon.com/cgi/ecrm.dll/ecrm/scripts/ public_download.jsp?oid=9746&parent_oid=-8984 AP2424: www.infineon.com/cgi/ecrm.dll/ecrm/scripts/ public_download.jsp?oid=9745&parent_oid=-8984 C164CI-8E, Step ES-DB, DB 20/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints MainOsc.H2 Maximum Oscillator Frequency = 16 MHz (Main: Type_LP2) The main oscillator is optimized for oscillation with a crystal within a frequency range of 4...16 MHz. When driven by an external clock signal it will accept the specified frequency range (see Data Sheet, AC Characteristics, tables ’Clock Generation Modes’ and ’External Clock Drive Characteristics’). Operation at lower input frequencies is possible but is guaranteed by design only (not 100% tested) (see Data Sheet, AC Characteristics, table ’External Clock Drive Characteristics’). OWD.H2 Oscillator Watchdog and Prescaler Mode The OWD replaces a missing oscillator clock signal with the PLL clock signal (base frequency). In direct drive mode the PLL base frequency is used directly (fCPU = 2...5 MHz). In prescaler mode the PLL base frequency is divided by 2 (fCPU = 1...2.5 MHz). C164CI-8E, Step ES-DB, DB 21/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints ISNC.H1 Maintenance of ISNC register The RTC and PLL interrupts share one interrupt node (XP3IC). If an interrupt request occurs the request bit in the Interrupt Subnode Control register has to be checked and cleared by software. To avoid a collision with the next hardware interrupt request of same source it is recommended to clear the request and the enable bit first and then to set the enable bit again. Example for an XP3 interrupt service routine (for Tasking C compiler): ... if (PLLIR) { _bfld (ISNC, 0x000C, 0x0000); _putbit (1, ISNC, 3); ... } if (RTCIR) { _bfld (ISNC, 0x0003, 0x0000); _putbit (1, ISNC, 1); ... } ... // clear PLLIE and PLLIR // set PLLIE // further actions concerning PLL/OWD // clear RTCIE and RTCIR // set RTCIE // further actions concerning RTC Example for an XP3 interrupt service routine (in assembly language): ... EXTR JNB EXTR #1 PLLIR, no_pll_request #2 ; no further interruption of this ; sequence possible BFLDL ISNC, #0Ch, #00h ; clear PLLIE and PLLIR BSET PLLIE ; set PLLIE ... ; further actions concerning PLL/OWD no_pll_request: EXTR #1 JNB RTCIR, no_rtc_request EXTR #2 ; no further interruption of this sequence possible BFLDL ISNC, #03h, #00h ; clear RTCIE and RTCIR BSET RTCIE ; set RTCIE ... ; further actions concerning RTC no_rtc_request: ... C164CI-8E, Step ES-DB, DB 22/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints C164CI-8E - Step DA Enhancements Compared to the Cx-step, the following feature enhancements have been implemented in the DA- (and all following) steps of the C164CI/SI. They are described in detail in the respective chapters of the C164 User's Manual or in the Documentation Update, and are summarized in Table 5 for easier reference. Table 5 C164CI-8E - Step DA enhancements Topic short description change necessary (Compared to the Cx-step) Single Chip Mode Reset Default Configuration and software setting of register RSTCON (After EINIT the Unlock Sequence is necessary to change RSTCON) yes - SW change **) see User’s Manual “20.4.2 System Startup Configuration upon a Single-Chip Mode Reset“ Bootstrap loader activation in single chip configuration (pin EA = high and pin RD is tied to low during HW reset) - restricted baudrate due to default fCPU = fOSC/2 after HW reset while pin EA = 1 yes - HW change **) see User’s Manual “20.4.2 System Startup Configuration upon a Single-Chip Mode Reset - Single-Chip Startup Modes“ Variable frequency output The system clock output (CLKOUT) can be no - new feature replaced by the programmable frequency see User’s Manual output signal fOUT . “21.6 Programmable Frequency Output Signal“ XRAM 2k bytes of on chip XRAM are enabled by no - if external address XPEN = 1 in register SYSCON range 0E000h ... 0E7FFh was not used (address range 0E000h ... 0E7FFh) before BUSCON switch WaitState A tristate waitstate is inserted if the next bus cycle accesses a different window than the one controlled by this BUSCON register (bit BSWCx in register BUSCONx) C164CI-8E, Step ES-DB, DB 23/28 no - new feature see User’s Manual “9.4 Controlling the External Bus Controller“ *) **) *) es, V1.1, 2005-04-07 Errata Sheet Application Hints Table 5 C164CI-8E - Step DA enhancements (cont’d) Topic short description change necessary (Compared to the Cx-step) *) **) Early Write Early write: The WR signal is deactivated and write data is tristated one TCL earlier (bit EWENx in register BUSCONx) no - new feature see User’s Manual “9.4 Controlling the External Bus Controller“ *) CAPCOM2 output pins Port 1H can be used as CC24...27 Compare Output no - new feature see User’s Manual “Table 16-1 CAPCOM Channel Port Connections“ CAPCOM2 channels eight additional channels available but no dedicated I/O pins no - new feature *) see User’s Manual “Table 16-1 CAPCOM Channel Port Connections“ CAPCOM6 version 5 implemented with significant improvements see application note AP1673 “Technical details on CAPCOM6 module - C164 family” **) Watchdog timer Watchdog Timer Input Prescaler implemented (bit WDTPRE in register WDTCON) no - new feature see User’s Manual “13.1 Operation of the Watchdog Timer“ *) Alternate interrupt inputs the modules ASC0 (RxD) and SSC (SCLK) can be used to wake up from IDLE or SLEEP mode by fast external interrupt (bitfields EX2IN and EX3IN in register EXISEL) no - new feature see User’s Manual “page 5-29 External Interrupt Source Control“ *) P4 Open Drain function Open Drain function for Port 4 available no - new feature see User’s Manual “7.7 Port 4“ *) CAN pins Pin Assignment selects a pair of port pins that connect the CAN module to the external transceiver. This is done via bitfield IPC in register PCIR. yes - SW change see User’s Manual “page 19-30 CAN Module Activation“ *) C164CI-8E, Step ES-DB, DB 24/28 es, V1.1, 2005-04-07 Errata Sheet Application Hints Table 5 C164CI-8E - Step DA enhancements (cont’d) Topic short description change necessary (Compared to the Cx-step) *) **) CAN register register IR replaced by register PCIR (including bitfield IPC) yes - SW change see User’s Manual “page 19-30 CAN Module Activation“ *) CAN clock prescaler bit CPS = 1 in CAN register CSR: Fast mode: the input clock is used directly 1:1. The minimum input frequency to achieve a baudrate of 1 MBaud is fCPU = 8 MHz. no - new feature see User’s Manual “19.2 General Functional Description“ Port Output Control Edge and Driver Characteristic can be selected (registers POCONx) see Documentation Update above yes - SW change see User’s Manual “7.2 Output Driver Control“ Sleep Mode In Sleep mode both the CPU and the peripherals are stopped (bitfield SLEEPCON in register SYSCON1) no - new feature see User’s Manual “21 Power Management“ **) *) function / feature not implemented in ROM type (C164CI-8E step Cx) **) different function in ROM type (C164CI-8E step Cx) C164CI-8E, Step ES-DB, DB 25/28 es, V1.1, 2005-04-07 Errata Sheet Documentation Update 5 Documentation Update TCOMP.D2 Temperature Compensation redesigned The new temperature compensation is disabled by default. The complete description can be found in the current User’s Manual. PORT.D3 P3.15 and Frequency Output Signal Path To enable the frequency output signal fOUT bit CLKEN in register SYSCON must be cleared (before EINIT) and fOUT must be enabled in register FOCON. In contrast to signal CLKOUT the direction latch has to be set by software to enable fOUT. Port Output Latch Write Read Write Read Internal Bus Direction Latch 1 0 0 1 AltDir_CLKOUT = '1' CLKEN fOUT 0 1 Pin 0 1 FOUT_active Driver fCPU Clock Input Latch MCB04353_315 C164CI-8E, Step ES-DB, DB 26/28 es, V1.1, 2005-04-07 Errata Sheet Documentation Update INT.D1 Data Sheet V2.0, 2001-05 - Special Function Registers Overview In contrast to Table 7 (Data Sheet V2.0, page 33...) the following CCxIC registers are not implemented: CC20IC, CC21IC, CC22IC, CC23IC, CC28IC, CC29IC, CC30IC and CC31IC. See also Table 3 C164CI Interrupt Nodes (page 17). PLL.D1 PLL goes to Unlocked State after Configuration When the PLL is (re-)configured via software by writing to register RSTCON, the PLL goes to an unlocked state first (CLKLOCK = SYSCON2.15 = 0) and the PLL interrupt request is set (flag PLLIR = ISNC.3 = 1) in the following cases: • SW configuration of a PLL mode after single chip mode reset (pin EA is High) when a PLL configuration is selected in bitfield CLKCFG (RSTCON.15 … 13), i.e. all selections except 001B and 011B. • SW re-configuration of a PLL mode in bitfield CLKCFG (RSTCON.15 … 13), i.e. all selections except 001B and 011B. When the PLL is locked again, bit CLKLOCK (SYSCON2.15) is set. A re-configuration of register RSTCON with the same CLKCFG setting does not influence the PLL. In direct drive and prescaler mode (bitfield CLKCFG = RSTCON.15 … 13 = 001B or 011B) the PLL cannot lock and bit CLKLOCK in register SYSCON2 remains cleared. Note: If PLLIR is set directly after reset the clock system is running on PLL base frequency (or PLL base frequency / 2) and fOSC is missing or was unstable during reset. Switching to SDD mode in this state could stop the system. To avoid an unintentional PLL interrupt during this SW configuration of RSTCON, it is recommended to disable the PLL interrupt while the PLL is in unlocked state. The example program for PLL modes shown below assumes that instruction EINIT has not been executed yet. After EINIT, unlock sequences must be used to change RSTCON and SYSCON2. To avoid a deadlock situation, the wait_for_CLKLOCK loop should be terminated after a timeout (before the WDT reset occurs). JB PLLIR, osc_clock_missing ; no osc clock before configuration ; is done, jump to emergency routine, ; don’t select SDD mode! disable_PLL_interrupt: EXTR #2 BCLR XP3IE ; disabled by default after reset BCLR PLLIE ; ISNC.3, disabled by default after reset C164CI-8E, Step ES-DB, DB 27/28 es, V1.1, 2005-04-07 Errata Sheet Documentation Update change_PLL_configuration: MOV R4, #0000110100000000b ; PLL * 2.5, no CS, no SEG addr. lines MOV RSTCON, R4 ; memory addressing mode only ; EXTR #2 MOV SYSCON2, #0400h MOV SYSCON2, #0000h ... ; ; ; ; ; (after EINIT unlock sequences are required for RSTCON and SYSCON2) SDD / 1 mode: enable RSTCON setting PLLIR is set when PLL mode is changed basic clock mode: activate setting some instructions while clock is not at final state wait_for_CLKLOCK: EXTR #1 JNB SYSCON2.15, wait_for_CLKLOCK ; timeout recommended PLL_locked: enable_PLL_interrupt: EXTR #3 MOV XP3IC, #0077h ; ; ; ; BFLDL ISNC, #0Ch, #00h BSET PLLIE ; ... clear requests, enable XP3 interrupt, int. level 13, group level 3 clear PLLIE and PLLIR enable PLL interrupt stable PLL clock VDD.D1 Data Sheet V2.0, 2001-05 - Operating Conditions In contrast to Table 9 (Data Sheet V2.0, page 42) VDD min. is 4.5 V for all devices listed in Table 1 (Data Sheet V2.0, page 2). Additionally, the OTP devices can be used up to 25 MHz operating frequency @ VDD min = 4.75 V. ID-Registers Register: IDMANUF IDCHIP Device IDMEM IDPROG IDMEM2 F07CH F07AH F078H F076 H C164CI-8E Step Address: F07EH -DA 1820H 0A04H 4010H 9340H 0000 H C164CI-8E -DB 0A05H 4010H 9340H 0000 H 1820H Product and Test Engineering Group, Munich C164CI-8E, Step ES-DB, DB 28/28 es, V1.1, 2005-04-07