ACG4000CE267

New
High rate discharge & high temperature type
Old
( HHR330APH)
BK330APH
PH type
LFat/A size
■ Dimensions (with tube)
■ Typical charge characteristics
ø 18.2 -+00.7
2.0
(+)
1.8
Voltage (V)
Charge : 320 mA(0.1 lt) × 16 hrs.
1.6
1.4
1.2
-10 ℃
20 ℃
60 ℃
1.0
+0
67.5 -1.5
0.8
0
2
4
6
8
10
12
Charge time (hours)
14
16
18
20
120
110
Unit: mm
■ Specifications
Diameter
Height
Approximate Weight
18.2 +0 / -0.7 mm
67.5 +0 / -1.5 mm
60 g
Nominal Voltage
1.2 V
Average *2
Rated (min.)
Charge
Rapid
*3
Low rate
Ambient Temperature
Standard
Charge
Rapid
Low rate
Discharge
Storage
80
70
60
40
30
-20
-10
0
10
20
30
40
50
60
70
Temperature (℃)
3,200 mAh
5.5 mΩ
320 mA X 16 hrs.
■ Typical discharge characteristics
1.8
1650 mA X 2.4 hrs.
-10 ℃ to 60 ℃
-10 ℃ to 45 ℃
-10 ℃ to 60 ℃
Charge : 1650 mA -dV = 5 mV, 20 ℃
Discharge : 20 ℃
1.7
165 mA X 32 hrs.
110 mA X 48 hrs.
1.6
10 A
20 A
1.5
1.4
1.3
1.2
1.1
<1 year
-20 ℃ to 35 ℃
1.0
<6 months
-20 ℃ to 45 ℃
0.9
<1 month
-20 ℃ to 55 ℃
0.8
<1 week
Charge : 320 mA (0.1 It) ×16 hrs.
Charge temperature : -10 to 60 ℃
Discharge : 640 mA(0.2 It)
Cut off voltage : 1.0 V
Discharge temperature : 20 ℃
3,300 mAh
Approx. Internal impedance
at 1000Hz at charged state.
Standard
90
50
Voltage (V)
*1
Discharge
Capacity
Capacity raito (%)
100
(- )
0
5
-20 ℃ to 65 ℃
10
15
20
25
30
Discharge time (minutes)
*1 After charging at 0.1 It for 16 hours, discharging at 0.2 It.
*2 For reference only.
*3 Need specially designed control system. Please contact Panasonic for details.
Battery performance and cycle life are strongly affected by how they are used. In order to
maximize battery safety, please consult Panasonic when determining charge/discharge
specs, warning label contents and unit design.
*The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty.
Nickel Metal Hydride Battery
2014/03