ACG4000CE294

New
Standard type
Old
( HHR450A)
BK450A
N
LFat/A size
■ Dimensions (with tube)
type
■ Typical charge characteristics
ø 18.2 -+00.7
2.0
(+ )
1.8
Charge : 2000 mA -dV = 5 mV
Voltage (V)
1.6
1.4
1.2
0℃
20 ℃
40 ℃
1.0
+0
67.5 -1.5
0.8
0
20
40
60
80
100
120
140
160
Charge time (minutes)
■ Typical discharge characteristics
1.8
Charge : 2000 mA -dV = 5 mV, 20 ℃
Discharge : 20 ℃
1.7
Unit: mm
(- )
1.6
18.2 +0 / -0.7 mm
67.5 +0 / -1.5 mm
60 g
Nominal Voltage
1.2 V
Average *2
Rated (min.)
Ambient Temperature
Charge
Standard
Rapid
1.0
0.9
0.8
0
1
2
3
4
5
6
Discharge time (hours)
4200 mAh
25 mΩ
420 mA X 16 hrs.
*3
1.8
2000 mA
0 °C to 45 °C
1.6
Rapid
0 ℃ to 40 ℃
1.5
-10 ℃ to 65 ℃
Charge : 2000 mA -dV = 5 mV, 20 ℃
Discharge : 20 ℃
1.7
Standard
Discharge
Storage
1.2
4500 mAh
Approx. Internal impedance
at 1000Hz at charged state.
Charge
1.4
1.3
1.1
Voltage (V)
*1
Voltage (V)
Diameter
Height
Approximate Weight
Discharge
Capacity
840 mA (0.2 lt)
1.5
■ Specifications
4200 mA (1 lt)
1.4
1.3
<1 year
-20 ℃ to 35 ℃
<6 months
-20 ℃ to 45 ℃
1.1
<1 month
-20 ℃ to 55 ℃
1.0
<1 week
-20 ℃ to 65 ℃
1.2
0.9
0.8
0
10
*1 After charging at 0.1 It for 16 hours, discharging at 0.2 It.
*2 For reference only.
*3 Need specially designed control system. Please contact Panasonic for details.
20
30
40
50
60
70
80
Discharge time (minutes)
Battery performance and cycle life are strongly affected by how they are used. In order to
maximize battery safety, please consult Panasonic when determining charge/discharge specs, warning label contents and unit design.
*The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty.
Nickel Metal Hydride Battery
2014/03