New Standard type Old ( HHR200A) BK200A N 4/5A size (HR17/43) ■ Dimensions (with tube) type ■ Typical charge characteristics 2.0 Charge : 1700 mA -dV = 10 mV 1.8 (+ ) 1.6 Voltage (V) ø 17.0 -+00.7 1.4 1.2 0℃ 20 ℃ 40 ℃ 1.0 +0 43.0 -1.5 0.8 0 20 40 60 80 100 Charge time (minutes) ■ Typical discharge characteristics (- ) 1.8 Charge : 1700 mA -dV = 10mV, 20 ℃ Discharge : 20 ℃ 1.7 Unit: mm 1.6 17.0 +0 / -0.7 mm 43.0 +0 / -1.5 mm 32 g Nominal Voltage 1.2 V Average *2 Rated (min.) Ambient Temperature Charge Standard Rapid *3 1.0 0.9 0.8 0 1 2 3 4 5 6 Discharge time (hours) 2000 mAh 20 mΩ 200 mA X 16 hrs. 1.8 1700 mA X 1.4 hrs. 0 °C to 45 °C 1.6 Rapid 0 ℃ to 40 ℃ 1.5 -10 ℃ to 65 ℃ Charge : 1700 mA -dV = 10mV, 20 ℃ Discharge : 20 ℃ 1.7 Standard Discharge Storage 1.2 2040 mAh Approx. Internal impedance at 1000Hz at charged state. Charge 1.4 1.3 1.1 Voltage (V) *1 Voltage (V) Diameter Height Approximate Weight Discharge Capacity 400 mA (0.2 lt) 1.5 ■ Specifications 2000 mA (1 It) 4000 mA (2 It) 1.4 1.3 <1 year -20 ℃ to 35 ℃ <6 months -20 ℃ to 45 ℃ 1.1 <1 month -20 ℃ to 55 ℃ 1.0 <1 week -20 ℃ to 65 ℃ 1.2 0.9 0.8 0 10 *1 After charging at 0.1 It for 16 hours, discharging at 0.2 It. *2 For reference only. *3 Need specially designed control system. Please contact Panasonic for details. 20 30 40 50 60 70 80 Discharge time (minutes) Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge/discharge specs, warning label contents and unit design. *The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Nickel Metal Hydride Battery 2014/03