ACG4000CE303

New
Standard type
Old
( HHR150AA)
BK150AA
N
AA size (HR15/51)
■ Dimensions (with tube)
type
■ Typical charge characteristics
2.0
Charge : 1500 mA -dV = 10 mV
ø 14.5 -+00.7
1.8
Voltage (V)
(+)
1.6
1.4
1.2
0℃
20 ℃
40 ℃
1.0
0.8
+0
50.5 -1.5
0
20
40
60
Charge time (minutes)
80
100
■ Typical discharge characteristics
1.8
(- )
Charge : 1500 mA -dV = 10mV, 20 ℃
Discharge : 20 ℃
1.7
Unit: mm
1.6
14.5 +0 / -0.7 mm
50.5 +0 / -1.5 mm
26 g
Nominal Voltage
1.2 V
Average *2
Rated (min.)
Ambient Temperature
Charge
Standard
Rapid
*3
1.0
0.9
0.8
0
1
2
3
4
Discharge time (hours)
5
6
1500 mAh
23 mΩ
150 mA X 16 hrs.
1.8
1500 mA X 1.2 hrs.
0 °C to 45 °C
1.6
Rapid
0 ℃ to 40 ℃
1.5
-10 ℃ to 65 ℃
Charge : 1500 mA -dV = 10mV, 20 ℃
Discharge : 20 ℃
1.7
Standard
Discharge
Storage
1.2
1580 mAh
Approx. Internal impedance
at 1000Hz at charged state.
Charge
1.4
1.3
1.1
Voltage (V)
*1
Voltage (V)
Diameter
Height
Approximate Weight
Discharge
Capacity
300 mA(0.2 lt)
1.5
■ Specifications
1500 mA (1 It)
3000 mA (2 It)
1.4
1.3
<1 year
-20 ℃ to 35 ℃
<6 months
-20 ℃ to 45 ℃
1.1
<1 month
-20 ℃ to 55 ℃
1.0
<1 week
-20 ℃ to 65 ℃
1.2
0.9
0.8
0
10
*1 After charging at 0.1 It for 16 hours, discharging at 0.2 It.
*2 For reference only.
*3 Need specially designed control system. Please contact Panasonic for details.
20
30
40
50
60
70
80
Discharge time (minutes)
Battery performance and cycle life are strongly affected by how they are used. In order to
maximize battery safety, please consult Panasonic when determining charge/discharge specs, warning label contents and unit design.
*The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty.
Nickel Metal Hydride Battery
2014/03