INTERSIL X9520V20IB

X9520
®
Fiber Channel/Gigabit Ethernet Laser Diode Control for Fiber Optic Modules
Data Sheet
PRELIMINARY
March 8, 2005
Triple DCP, POR, 2kbit EEPROM Memory,
Dual Voltage Monitors
FN8206.0
DESCRIPTION
The X9520 combines three Digitally Controlled Potentiometers (DCPs), V1 / Vcc Power-on Reset (POR) circuitry, two programmable voltage monitor inputs with
software and hardware indicators, and integrated
EEPROM with Block Lock™ protection. All functions of
the X9520 are accessed by an industry standard 2-Wire
serial interface.
FEATURES
• Three Digitally Controlled Potentiometers (DCPs)
—64 Tap - 10kΩ
—100 Tap - 10kΩ
—256 Tap - 100kΩ
—Nonvolatile
—Write Protect Function
• 2kbit EEPROM Memory with Write Protect & Block
LockTM
• 2-Wire industry standard Serial Interface
—Complies to the Gigabit Interface Converter
(GBIC) specification
• Power-on Reset (POR) Circuitry
—Programmable Threshold Voltage
—Software Selectable reset timeout
—Manual Reset
• Two Supplementary Voltage Monitors
—Programmable Threshold Voltages
• Single Supply Operation
—2.7V to 5.5V
• Hot Pluggable
• 20 Pin packages
—CSP (Chip Scale Package)
—TSSOP
Two of the DCPs of the X9520 may be utilized to control
the bias and modulation currents of the laser diode in a
Fiber Optic module. The third DCP may be used to set
other various reference quantities, or as a coarse trim
for one of the other two DCPs. The 2kbit integrated
EEPROM may be used to store module definition data.
The programmable POR circuit may be used to ensure
that V1 / Vcc is stable before power is applied to the
laser diode / module. The programmable voltage monitors may be used for monitoring various module alarm
levels.
The features of the X9520 are ideally suited to simplifying the design of fiber optic modules which comply to
the Gigabit Interface Converter (GBIC) specification.
The integration of these functions into one package significantly reduces board area, cost and increases reliability of laser diode modules.
BLOCK DIAGRAM
RH0
WIPER
COUNTER
REGISTER
RW0
RL0
8
WP
6 - BIT
NONVOLATILE
MEMORY
PROTECT LOGIC
RH1
CONSTAT
SDA
SCL
WIPER
COUNTER
REGISTER
REGISTER
DATA
REGISTER
4
COMMAND
DECODE &
CONTROL
LOGIC
RW1
RL1
7 - BIT
NONVOLATILE
MEMORY
2kbit
EEPROM
ARRAY
RH2
WIPER
COUNTER
REGISTER
THRESHOLD
RESET LOGIC
RW2
RL2
MR
2
+
V3RO
VTRIP3
+
V2RO
VTRIP 2
VTRIP 1
+
-
V3
V2
V1 / Vcc
1
8 - BIT
NONVOLATILE
MEMORY
POWER-ON /
LOW VOLTAGE
RESET
GENERATION
V1RO
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-352-6832 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
©2000 Intersil Inc., Patents Pending. Copyright Intersil Americas Inc. 2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
X9520
output (V3RO, V2RO) are allowed to go HIGH. If the
input voltage becomes lower than it’s associated trip
level, the corresponding output is driven LOW. A
corresponding binary representation of the two monitor
circuit outputs (V2RO and V3RO) are also stored in
latched, volatile (CONSTAT) register bits. The status of
these two monitor outputs can be read out via the 2-wire
serial port.
DETAILED DEVICE DESCRIPTION
The X9520 combines three Intersil Digitally Controlled
Potentiometer (DCP) devices, V1 / Vcc power-on reset
control, V1 / Vcc low voltage reset control, two supplementary voltage monitors, and integrated EEPROM with
Block Lock™ protection, in one package. These functions are suited to the control, support, and monitoring of
various system parameters in Fiber Channel / Gigabit
Ethernet fiber optic modules, such as in Gigabit Interface
Converter (GBIC) applications. The combination of the
X9520 fucntionality lowers system cost, increases reliability, and reduces board space requirements using
Intersil’s unique XBGA™ packaging.
An application of the V1RO output may be to drive the
“ENABLE” input of a Laser Driver IC, with MR as a
“TX_DISABLE” input. V2RO and V3RO may be used to
monitor “TX_FAULT” and “RX_LOS” conditions respectively.
Two high resolution DCPs allow for the “set-and-forget”
adjustment of Laser Driver IC parameters such as Laser
Diode Bias and Modulation Currents. One lower resolution DCP may be used for setting sundry system parameters such as maximum laser output power (for eye
safety requirements).
Intersil’s unique circuits allow for all internal trip voltages
to be individually programmed with high accuracy. This
gives the designer great flexibility in changing system
parameters, either at the time of manufacture, or in the
field.
The memory portion of the device is a CMOS serial
EEPROM array with Intersil’s Block Lock™ protection.
This memory may be used to store fiber optic module
manufacturing data, serial numbers, or various other system parameters. The EEPROM array is internally organized as x 8, and utilizes Intersil’s proprietary Direct
Write™ cells, providing a minimum endurance of
1,000,000 cycles and a minimum data retention of 100
years.
Applying voltage to VCC activates the Power-on Reset
circuit which allows the V1RO output to go HIGH, until
the supply the supply voltage stabilizes for a period of
time (selectable via software). The V1RO output then
goes LOW. The Low Voltage Reset circuitry allows the
V1RO output to go HIGH when VCC falls below the minimum VCC trip point. V1RO remains HIGH until VCC
returns to proper operating level. A Manual Reset (MR)
input allows the user to externally trigger the V1RO output (HIGH).
The device features a 2-Wire interface and software
protocol allowing operation on an I2C™ compatible
serial bus.
Two supplementary Voltage Monitor circuits continuously
compare their inputs to individual trip voltages. If an input
voltage exceeds it’s associated trip level, a hardware
PIN CONFIGURATION
CSP
20 Pin TSSOP
1
RH2
RW2
RL2
V3
V3RO
MR
WP
1
2
3
4
5
6
SCL
7
8
SDA
VSS
9
10
2
3
4
V1 / Vcc
20
19
18
17
V1RO
V2RO
V2
RL0
RW0
16
15
14
13
12
11
RH0
RH1
A
V2RO V1 / Vcc RW2
RL2
V2
V1RO
RH2
V3
RW0
RL0
V3RO
WP
RH1
RH0
MR
SCL
VSS
RW1
RL1
SDA
B
C
D
RW1
RL1
E
Top View – Bumps Down
NOT TO SCALE
2
FN8206.0
March 8, 2005
X9520
PIN ASSIGNMENT
TSSOP
CSP
Name
1
B3
RH2
Connection to end of resistor array for (the 256 Tap) DCP 2.
2
A3
Rw2
Connection to terminal equivalent to the “Wiper” of a mechanical potentiometer for DCP 2.
3
A4
RL2
Connection to other end of resistor array for (the 256 Tap) DCP 2.
4
B4
V3
V3 Voltage Monitor Input. V3 is the input to a non-inverting voltage comparator circuit. When
the V3 input is higher than the VTRIP3 threshold voltage, V3RO makes a transition to a
HIGH level. Connect V3 to VSS when not used.
5
C3
V3RO
V3 RESET Output. This open drain output makes a transition to a HIGH level when V3 is
greater than VTRIP3 and goes LOW when V3 is less than VTRIP3. There is no delay circuitry on this pin. The V3RO pin requires the use of an external “pull-up” resistor.
MR
Manual Reset. MR is a TTL level compatible input. Pulling the MR pin active (HIGH) initiates
a reset cycle to the V1RO pin (V1 / Vcc RESET Output pin). V1RO will remain HIGH for time
tpurst after MR has returned to it’s normally LOW state. The reset time can be selected using
bits POR1 and POR0 in the CONSTAT Register. The MR pin requires the use of an external
“pull-down” resistor.
6
D3
Function
7
C4
WP
Write Protect Control Pin. WP pin is a TTL level compatible input. When held HIGH, Write Protection is enabled. In the enabled state, this pin prevents all nonvolatile “write” operations. Also, when the Write Protection is enabled, and the device Block Lock feature is active (i.e. the
Block Lock bits are NOT [0,0]), then no “write” (volatile or nonvolatile) operations can be performed in the device (including the wiper position of any of the integrated Digitally Controlled
Potentiometers (DCPs). The WP pin uses an internal “pull-down” resistor, thus if left floating
the write protection feature is disabled.
8
D4
SCL
Serial Clock. This is a TTL level compatible input pin used to control the serial bus timing for
data input and output.
9
E4
SDA
Serial Data. SDA is a bidirectional TTL level compatible pin used to transfer data into and
out of the device. The SDA pin input buffer is always active (not gated). This pin requires an
external pull up resistor.
10
E1
Vss
Ground.
11
E3
RL1
Connection to other end of resistor for (the 100 Tap) DCP 1.
12
E2
Rw1
Connection to terminal equivalent to the “Wiper” of a mechanical potentiometer for DCP 1.
13
D1
RH1
Connection to end of resistor array for (the 100 Tap) DCP 1.
14
D2
RH0
Connection to end of resistor array for (the 64 Tap) Digitally Controlled Potentiometer (DCP) 0.
15
C1
RW0
Connection to terminal equivalent to the “Wiper” of a mechanical potentiometer for DCP 0.
16
C2
RL0
Connection to the other end of resistor array for (the 64 Tap) DCP 0.
17
B1
V2
V2 Voltage Monitor Input. V2 is the input to a non-inverting voltage comparator circuit. When
the V2 input is greater than the VTRIP2 threshold voltage, V2RO makes a transition to a
HIGH level. Connect V2 to VSS when not used.
V2RO
V2 RESET Output. This open drain output makes a transition to a HIGH level when V2 is
greater than VTRIP2, and goes LOW when V2 is less than VTRIP2. There is no power-up
reset delay circuitry on this pin. The V2RO pin requires the use of an external “pull-up” resistor.
V1 / Vcc RESET Output. This is an active HIGH, open drain output which becomes active
whenever V1 / Vcc falls below VTRIP1. V1RO becomes active on power-up and remains
active for a time tpurst after the power supply stabilizes (tpurst can be changed by varying the
POR0 and POR1 bits of the internal control register). The V1RO pin requires the use of an
external “pull-up” resistor. The V1RO pin can be forced active (HIGH) using the manual reset
(MR) input pin.
18
A1
19
B2
V1RO
20
A2
V1 / Vcc
3
Supply Voltage.
FN8206.0
March 8, 2005
X9520
SCL
SDA
Data Stable
Figure 1.
Data Change
Data Stable
Valid Data Changes on the SDA Bus
Serial Stop Condition
PRINCIPLES OF OPERATION
SERIAL INTERFACE
Serial Interface Conventions
The device supports a bidirectional bus oriented protocol.
The protocol defines any device that sends data onto the
bus as a transmitter, and the receiving device as the
receiver. The device controlling the transfer is called the
master and the device being controlled is called the
slave. The master always initiates data transfers, and
provides the clock for both transmit and receive operations. Therefore, the X9520 operates as a slave in all
applications.
Serial Clock and Data
Data states on the SDA line can change only while SCL
is LOW. SDA state changes while SCL is HIGH are
reserved for indicating START and STOP conditions.
See Figure 1. On power-up of the X9520, the SDA pin is
in the input mode.
All communications must be terminated by a STOP
condition, which is a LOW to HIGH transition of SDA
while SCL is HIGH. The STOP condition is also used to
place the device into the Standby power mode after a
read sequence. A STOP condition can only be issued
after the transmitting device has released the bus. See
Figure 2.
Serial Acknowledge
An ACKNOWLE DGE (ACK) is a software convention
used to indicate a successful data transfer. The transmitting device, either master or slave, will release the
bus after transmitting eight bits. During the ninth clock
cycle, the receiver will pull the SDA line LOW to
ACKNOWLEDGE that it received the eight bits of data.
Refer to Figure 3.
Serial Start Condition
The device will respond with an ACKNOWLEDGE after
recognition of a START condition if the correct Device
Identifier bits are contained in the Slave Address Byte. If
a write operation is selected, the device will respond with
an ACKNOWLEDGE after the receipt of each subsequent eight bit word.
All commands are preceded by the START condition,
which is a HIGH to LOW transition of SDA while SCL is
HIGH. The device continuously monitors the SDA and
SCL lines for the START condition and does not respond
to any command until this condition has been met. See
Figure 2.
In the read mode, the device will transmit eight bits of
data, release the SDA line, then monitor the line for an
ACKNOWLEDGE. If an ACKNOWLEDGE is detected
and no STOP condition is generated by the master, the
device will continue to transmit data. The device will ter-
SCL
SDA
Start
Figure 2.
4
Stop
Valid Start and Stop Conditions
FN8206.0
March 8, 2005
X9520
SCL
from
Master
Data Output
from
Transmitter
Data Output
from
Receiver
1
8
9
Start
Figure 3.
Acknowledge
Acknowledge Response From Receiver
minate further data transmissions if an ACKNOWLEDGE
is not detected. The master must then issue a STOP
condition to place the device into a known state.
DEVICE INTERNAL ADDRESSING
Addressing Protocol Overview
The user addressable internal components of the X9520
can be split up into three main parts:
—Three Digitally Controlled Potentiometers (DCPs)
—EEPROM array
—The next three bits (SA3 - SA1) are the Internal Device
Address bits. Setting these bits to 000 internally
selects the EEPROM array, while setting these bits to
111 selects the DCP structures in the X9520. The
CONSTAT Register may be selected using the Internal Device Address 010.
—The Least Significant Bit of the Slave Address (SA0)
Byte is the R/W bit. This bit defines the operation to be
performed on the device being addressed (as defined
in the bits SA3 - SA1). When the R/W bit is “1”, then a
READ operation is selected. A “0” selects a WRITE
operation (Refer to Figure 4.)
—Control and Status (CONSTAT) Register
SA7
Depending upon the operation to be performed on each
of these individual parts, a 1, 2 or 3 Byte protocol is used.
All operations however must begin with the Slave
Address Byte being issued on the SDA pin. The Slave
address selects the part of the X9520 to be addressed,
and specifies if a Read or Write operation is to be performed.
It should be noted that in order to perform a write operation to either a DCP or the EEPROM array, the Write
Enable Latch (WEL) bit must first be set (See “BL1, BL0:
Block Lock protection bits - (Nonvolatile)” on page 13.)
Slave Address Byte
Following a START condition, the master must output a
Slave Address Byte (Refer to Figure 4.). This byte consists of three parts:
—The Device Type Identifier which consists of the most
significant four bits of the Slave Address (SA7 - SA4).
The Device Type Identifier must always be set to 1010
in order to select the X9520.
5
SA6 SA5
SA4
1 0 1
DEVICE TYPE
IDENTIFIER
SA3
SA2
SA1
0
SA0
R/W
INTERNAL
DEVICE
ADDRESS
READ /
WRITE
(SA3 - SA1)
Internally Addressed
Device
000
EEPROM Array
010
CONSTAT Register
111
DCP
Internal Address
Bit SA0
Operation
0
WRITE
1
READ
Figure 4.
Slave Address Format
FN8206.0
March 8, 2005
X9520
Nonvolatile Write Acknowledge Polling
After a nonvolatile write command sequence (for either
the EEPROM array, the Non Volatile Memory of a DCP
(NVM), or the CONSTAT Register) has been correctly
issued (including the final STOP condition), the X9520
initiates an internal high voltage write cycle. This cycle
typically requires 5 ms. During this time, no further Read
or Write commands can be issued to the device. Write
Acknowledge Polling is used to determine when this high
voltage write cycle has been completed.
To perform acknowledge polling, the master issues a
START condition followed by a Slave Address Byte. The
Slave Address issued must contain a valid Internal
Device Address. The LSB of the Slave Address (R/W)
can be set to either 1 or 0 in this case. If the device is still
busy with the high voltage cycle then no ACKNOWLEDGE will be returned. If the device has completed the
write operation, an ACKNOWLEDGE will be returned
and the host can then proceed with a read or write operation (Refer to Figure 5.).
WIPER
COUNTER
REGISTER
(WCR)
DECODER
“WIPER”
FET
SWITCHES
RESISTOR
ARRAY
2
NON
VOLATILE
MEMORY
(NVM)
1
0
RLx
RWx
Figure 6.
DCP Internal Structure
DIGITALLY CONTROLLED POTENTIOMETERS
Byte load completed
by issuing STOP.
Enter ACK Polling
DCP Functionality
Issue START
Issue Slave Address
Byte (Read or Write)
Issue STOP
YES
High Voltage Cycle
NO
Issue STOP
complete. Continue
The X9520 includes three independent resistor arrays.
These arrays respectively contain 63, 99 and 255
discrete resistive segments that are connected in series.
The physical ends of each array are equivalent to the
fixed terminals of a mechanical potentiometer (RHx and
RLx inputs - where x = 0,1,2).
At both ends of each array and between each resistor
segment there is a CMOS switch connected to the wiper
(Rwx) output. Within each individual array, only one
switch may be turned on at any one time. These
switches are controlled by the Wiper Counter Register
(WCR) (See Figure 6). The WCR is a volatile register.
NO
ACK
returned?
command sequence?
YES
Continue normal
Read or Write
command sequence
PROCEED
Figure 5.
RHx
N
On power-up of the X9520, wiper position data is automatically loaded into the WCR from its associated Non
Volatile Memory (NVM) Register. The Table below
shows the Initial Values of the DCP WCR’s before the
contents of the NVM is loaded into the WCR.
DCP
Initial Values Before Recall
R0 / 64 TAP
VH / TAP = 63
R1 / 100 TAP
VL / TAP = 0
R2 / 256 TAP
VH / TAP = 255
Acknowledge Polling Sequence
6
FN8206.0
March 8, 2005
X9520
V1 / Vcc
V1 / Vcc (Max.)
VTRIP1
ttrans
tpurst
t
0
Maximum Wiper Recall time
Figure 7.
DCP Power
The data in the WCR is then decoded to select and
enable one of the respective FET switches. A “make
before break” sequence is used internally for the FET
switches when the wiper is moved from one tap position
to another.
Hot Pluggability
Figure 7 shows a typical waveform that the X9520 might
experience in a Hot Pluggable situation. On power-up,
V1 / Vcc applied to the X9520 may exhibit some amount
of ringing, before it settles to the required value.
The device is designed such that the wiper terminal
(RWx) is recalled to the correct position (as per the last
stored in the DCP NVM), when the voltage applied to V1
/ Vcc exceeds VTRIP1 for a time exceeding tpurst (the
Power-on Reset time, set in the CONSTAT Register See “CONTROL AND STATUS REGISTER” on
page 13.).
Therefore, if ttrans is defined as the time taken for V1 /
Vcc to settle above VTRIP1 (Figure 7): then the desired
wiper terminal position is recalled by (a maximum) time:
ttrans + tpurst. It should be noted that ttrans is determined by system hot plug conditions.
DCP Operations
In total there are three operations that can be performed
on any internal DCP structure:
—DCP Nonvolatile Write
—DCP Volatile Write
—DCP Read
A nonvolatile write to a DCP will change the “wiper
position” by simultaneously writing new data to the
associated WCR and NVM. Therefore, the new “wiper
position” setting is recalled into the WCR after V1 / Vcc of
the X9520 is powered down and then powered back up.
7
A volatile write operation to a DCP however, changes the
“wiper position” by writing new data to the associated
WCR only. The contents of the associated NVM register
remains unchanged. Therefore, when V1 / Vcc to the
device is powered down then back up, the “wiper
position” reverts to that last position written to the DCP
using a nonvolatile write operation.
Both volatile and nonvolatile write operations are
executed using a three byte command sequence: (DCP)
Slave Address Byte, Instruction Byte, followed by a Data
Byte (See Figure 9)
A DCP Read operation allows the user to “read out” the
current “wiper position” of the DCP, as stored in the
associated WCR. This operation is executed using the
Random Address Read command sequence, consisting
of the (DCP) Slave Address Byte followed by an
Instruction Byte and the Slave Address Byte again (Refer
to Figure 10.).
Instruction Byte
While the Slave Address Byte is used to select the DCP
devices, an Instruction Byte is used to determine which
DCP is being addressed.
The Instruction Byte (Figure 8) is valid only when the
Device Type Identifier and the Internal Device Address
bits of the Slave Address are set to 1010111. In this
case, the two Least Significant Bit’s (I1 - I0) of the
Instruction Byte are used to select the particular DCP (0
- 2). In the case of a Write to any of the DCPs (i.e. the
LSB of the Slave Address is 0), the Most Significant Bit of
the Instruction Byte (I7), determines the Write Type (WT)
performed.
If WT is “1”, then a Nonvolatile Write to the DCP occurs.
In this case, the “wiper position” of the DCP is changed
by simultaneously writing new data to the associated
FN8206.0
March 8, 2005
X9520
I7
WT
I6
I5
I4
I3
I2
0
0
0
0
0
I1
P1
WRITE TYPE
Next, an Instruction Byte is issued on SDA. Bits P1 and
P0 of the Instruction Byte determine which WCR is to be
written, while the WT bit determines if the Write is to be
volatile or nonvolatile. If the Instruction Byte format is
valid, another ACKNOWLEDGE is then returned by the
X9520.
I0
P0
DCP SELECT
WT†
Description
0
Select a Volatile Write operation to be performed
on the DCP pointed to by bits P1 and P0
1
Select a Nonvolatile Write operation to be performed on the DCP pointed to by bits P1 and P0
Following the Instruction Byte, a Data Byte is issued to
the X9520 over SDA. The Data Byte contents is latched
into the WCR of the DCP on the first rising edge of the
clock signal, after the LSB of the Data Byte (D0) has
been issued on SDA (See Figure 34).
The Data Byte determines the “wiper position” (which
FET switch of the DCP resistive array is switched ON) of
the DCP. The maximum value for the Data Byte depends
upon which DCP is being addressed (see Table below).
†This bit has no effect when a Read operation is being performed.
Figure 8.
Instruction Byte Format
WCR and NVM. Therefore, the new “wiper position” setting is recalled into the WCR after V1 / Vcc of the X9520
has been powered down then powered back up
If WT is “0” then a DCP Volatile Write is performed. This
operation changes the DCP “wiper position” by writing
new data to the associated WCR only. The contents of
the associated NVM register remains unchanged. Therefore, when V1 / Vcc to the device is powered down then
back up, the “wiper position” reverts to that last written to
the DCP using a nonvolatile write operation.
In order to perform a write operation on a particular DCP,
the Write Enable Latch (WEL) bit of the CONSTAT Register must first be set (See “BL1, BL0: Block Lock protection bits - (Nonvolatile)” on page 13.)
The Slave Address Byte 10101110 specifies that a Write
to a DCP is to be conducted. An ACKNOWLEDGE is
returned by the X9520 after the Slave Address, if it has
been received correctly.
1
0
1
1
1
SLAVE ADDRESS BYTE
Figure 9.
8
0
A WT
C
K
0
0
0
# Taps
Max. Data Byte
0
0
x=0
64
3Fh
0
1
x=1
100
Refer to Appendix 1
1
0
x=2
256
FFh
1
1
Reserved
For DCP0 (64 Tap) and DCP2 (256 Tap), the Data Byte
maps one to one to the “wiper position” of the DCP
“wiper terminal”. Therefore, the Data Byte 00001111
(1510) corresponds to setting the “wiper terminal” to tap
position 15. Similarly, the Data Byte 00011100 (2810)
corresponds to setting the “wiper terminal” to tap position
28. The mapping of the Data Byte to “wiper position” data
for DCP1 (100 Tap), is shown in “APPENDIX 1” . An
example of a simple C language function which “translates” between the tap position (decimal) and the Data
Byte (binary) for DCP1, is given in “APPENDIX 2” .
A write to DCPx (x = 0,1,2) can be performed using the
three byte command sequence shown in Figure 9.
0
DCPx
Using a Data Byte larger than the values specified above
results in the “wiper terminal” being set to the highest tap
position. The “wiper position” does NOT roll-over to the
lowest tap position.
DCP Write Operation
S 1
T
A
R
T
P1 - P0
0
0
P1 P0
INSTRUCTION BYTE
A
C
K
D7 D6 D5 D4 D3 D2 D1 D0
DATA BYTE
A
C
K
S
T
O
P
DCP Write Command Sequence
FN8206.0
March 8, 2005
X9520
WRITE Operation
S
t
a
r
t
Signals from
the Master
SDA Bus
Slave
Address
Instruction
Byte
10101110
W 00000 P P
1 0
T
A
C
K
Signals from
the Slave
S
t
a
r
t
READ Operation
Slave
Address
S
t
o
p
Data Byte
10101111
A
C
K
A
C
K
“Dummy” write
DCPx
- -
x=0
-
x=1
x=2
LSB
MSB
“-” = DON’T CARE
Figure 10.
DCP Read Sequence
It should be noted that all writes to any DCP of the X9520
are random in nature. Therefore, the Data Byte of consecutive write operations to any DCP can differ by an
arbitrary number of bits. Also, setting the bits P1 = 1,
P0 = 1 is a reserved sequence, and will result in no
ACKNOWLEDGE after sending an Instruction Byte on
SDA.
operation). An ACKNOWLEDGE is returned by the
X9520 after the Slave Address if received correctly. Next,
an Instruction Byte is issued on SDA. Bits P1-P0 of the
Instruction Byte determine which DCP “wiper position” is
to be read. In this case, the state of the WT bit is “don’t
care”. If the Instruction Byte format is valid, then another
ACKNOWLEDGE is returned by the X9520.
The factory default setting of all “wiper position” settings
is with 00h stored in the NVM of the DCPs. This corresponds to having the “wiper teminal” RWX (x = 0,1,2) at
the “lowest” tap position, Therefore, the resistance
between RWX and RLX is a minimum (essentially only
the Wiper Resistance, RW).
Following this ACKNOWLEDGE, the master immediately
issues another START condition and a valid Slave
address byte with the R/W bit set to 1. Then the X9520
issues an ACKNOWLEDGE followed by Data Byte, and
finally, the master issues a STOP condition. The Data
Byte read in this operation, corresponds to the “wiper
position” (value of the WCR) of the DCP pointed to by
bits P1 and P0.
DCP Read Operation
A read of DCPx (x = 0,1,2) can be performed using the
three byte random read command sequence shown in
Figure 10.
It should be noted that when reading out the data byte
for DCP0 (64 Tap), the upper two most significant bits
are “unknown” bits. For DCP1 (100 Tap), the upper
most significant bit is an “unknown”. For DCP2 (256
Tap) however, all bits of the data byte are relevant (See
Figure 10).
The master issues the START condition and the Slave
Address Byte 10101110 which specifies that a “dummy”
write” is to be conducted. This “dummy” write operation
sets which DCP is to be read (in the preceding Read
Signals from
the Master
SDA Bus
Signals from
the Slave
S
t
a
r
t
WRITE Operation
Address
Byte
Slave
Address
S
t
o
p
Data
Byte
1 01 00 00 0
Internal
Device
Address
A
C
K
A
C
K
A
C
K
Figure 11. EEPROM Byte Write Sequence
9
FN8206.0
March 8, 2005
X9520
Signals from
the Master
SDA Bus
S
t
a
r
t
S
t
o
p
(2 < n < 16)
Address
Byte
Slave
Address
Data
(n)
Data
(1)
1 01 00 00 0
Signals from
the Slave
A
C
K
A
C
K
A
C
K
A
C
K
Figure 12. EEPROM Page Write Operation
EEPROM Page Write
2kbit EEPROM ARRAY
Operations on the 2kbit EEPROM Array, consist of either
1, 2 or 3 byte command sequences. All operations on the
EEPROM must begin with the Device Type Identifier of
the Slave Address set to 1010000. A Read or Write to
the EEPROM is selected by setting the LSB of the Slave
Address to the appropriate value R/W (Read = “1”,
Write = ”0”).
In some cases when performing a Read or Write to the
EEPROM, an Address Byte may also need to be specified. This Address Byte can contain the values 00h to
FFh.
EEPROM Byte Write
In order to perform an EEPROM Byte Write operation to
the EEPROM array, the Write Enable Latch (WEL) bit of
the CONSTAT Register must first be set (See “BL1, BL0:
Block Lock protection bits - (Nonvolatile)” on page 13.)
For a write operation, the X9520 requires the Slave
Address Byte and an Address Byte. This gives the master access to any one of the words in the array. After
receipt of the Address Byte, the X9520 responds with an
ACKNOWLEDGE, and awaits the next eight bits of data.
After receiving the 8 bits of the Data Byte, it again
responds with an ACKNOWLEDGE. The master then
terminates the transfer by generating a STOP condition,
at which time the X9520 begins the internal write cycle to
the nonvolatile memory (See Figure 11). During this
internal write cycle, the X9520 inputs are disabled, so it
does not respond to any requests from the master. The
SDA output is at high impedance. A write to a region of
EEPROM memory which has been protected with the
Block-Lock feature (See “BL1, BL0: Block Lock protection bits - (Nonvolatile)” on page 13.), suppresses the
ACKNOWLEDGE bit after the Address Byte.
10
In order to perform an EEPROM Page Write operation to
the EEPROM array, the Write Enable Latch (WEL) bit of
the CONSTAT Register must first be set (See “BL1, BL0:
Block Lock protection bits - (Nonvolatile)” on page 13.)
The X9520 is capable of a page write operation. It is initiated in the same manner as the byte write operation; but
instead of terminating the write cycle after the first data
byte is transferred, the master can transmit an unlimited
number of 8-bit bytes. After the receipt of each byte, the
X9520 responds with an ACKNOWLEDGE, and the
address is internally incremented by one. The page
address remains constant. When the counter reaches
the end of the page, it “rolls over” and goes back to ‘0’ on
the same page.
For example, if the master writes 12 bytes to the page
starting at location 11 (decimal), the first 5 bytes are written to locations 11 through 15, while the last 7 bytes are
written to locations 0 through 6. Afterwards, the address
counter would point to location 7. If the master supplies
more than 16 bytes of data, then new data overwrites the
previous data, one byte at a time (See Figure 13).
The master terminates the Data Byte loading by issuing
a STOP condition, which causes the X9520 to begin the
nonvolatile write cycle. As with the byte write operation,
all inputs are disabled until completion of the internal
write cycle. See Figure 12 for the address, ACKNOWLEDGE, and data transfer sequence.
Stops and EEPROM Write Modes
Stop conditions that terminate write operations must be
sent by the master after sending at least 1 full data byte
and receiving the subsequent ACKNOWLEDGE signal.
If the master issues a STOP within a Data Byte, or before
the X9520 issues a corresponding ACKNOWLEDGE,
the X9520 cancels the write operation. Therefore, the
contents of the EEPROM array does not change.
FN8206.0
March 8, 2005
X9520
Signals from
the Master
S
t
a
r
t
SDA Bus
S
t
o
p
Slave
Address
1 01 0 0 0 0 1
Signals from
the Slave
A
C
K
Data
Figure 14. Current EEPROM Address Read Sequence
EEPROM Array Read Operations
Read operations are initiated in the same manner as
write operations with the exception that the R/W bit of the
Slave Address Byte is set to one. There are three basic
read operations: Current EEPROM Address Read, Random EEPROM Read, and Sequential EEPROM Read.
Current EEPROM Address Read
Internally the device contains an address counter that
maintains the address of the last word read incremented
by one. Therefore, if the last read was to address n, the
next read operation would access data from address
n+1. On power-up, the address of the address counter is
undefined, requiring a read or write operation for initialization.
Upon receipt of the Slave Address Byte with the R/W bit
set to one, the device issues an ACKNOWLEDGE and
then transmits the eight bits of the Data Byte. The master
terminates the read operation when it does not respond
with an ACKNOWLEDGE during the ninth clock and then
issues a STOP condition (See Figure 14 for the address,
ACKNOWLEDGE, and data transfer sequence).
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read operation, the master must either issue a STOP condition
during the ninth cycle or hold SDA HIGH during the ninth
clock cycle and then issue a STOP condition.
Another important point to note regarding the “Current
EEPROM Address Read” , is that this operation is not
available if the last executed operation was an access to
a DCP or the CONSTAT Register (i.e.: an operation
using the Device Type Identifier 1010111 or 1010010).
Immediately after an operation to a DCP or CONSTAT
Register is performed, only a “Random EEPROM Read”
is available. Immediately following a “Random EEPROM
Read” , a “Current EEPROM Address Read” or “Sequential EEPROM Read” is once again available (assuming
that no access to a DCP or CONSTAT Register occur in
the interim).
Random EEPROM Read
Random read operation allows the master to access any
memory location in the array. Prior to issuing the Slave
Address Byte with the R/W bit set to one, the master
must first perform a “dummy” write operation. The master
issues the START condition and the Slave Address Byte,
receives an ACKNOWLEDGE, then issues an Address
5 bytes
5 bytes
7 bytes
address
1110
address
= 6 10
address
1510
address pointer
ends here
Addr = 710
Figure 13. Example: Writing 12 bytes to a 16-byte page starting at location 11.
11
FN8206.0
March 8, 2005
X9520
Signals from
the Master
SDA Bus
READ Operation
WRITE Operation
S
t
a
r
t
Slave
Address
S
t
Slave
a
r Address
t
Address
Byte
10100001
10 1 0 0 0 0 0
A
C
K
Signals from
the Slave
S
t
o
p
A
C
K
A
C
K
Data
“Dummy” Write
Figure 15. Random EEPROM Address Read Sequence
Byte. This “dummy” Write operation sets the address
pointer to the address from which to begin the random
EEPROM read operation.
After the X9520 acknowledges the receipt of the Address
Byte, the master immediately issues another START
condition and the Slave Address Byte with the R/W bit
set to one. This is followed by an ACKNOWLEDGE from
the X9520 and then by the eight bit word. The master terminates the read operation by not responding with an
ACKNOWLEDGE and instead issuing a STOP condition
(Refer to Figure 15.).
A similar operation called “Set Current Address” also
exists. This operation is performed if a STOP is issued
instead of the second START shown in Figure 15. In this
case, the device sets the address pointer to that of the
Address Byte, and then goes into standby mode after the
STOP bit. All bus activity will be ignored until another
START is detected.
Signals from
the Master
SDA Bus
Slave
Address
Sequential EEPROM Read
Sequential reads can be initiated as either a current
address read or random address read. The first Data
Byte is transmitted as with the other modes; however,
the master now responds with an ACKNOWLEDGE,
indicating it requires additional data. The X9520 continues to output a Data Byte for each ACKNOWLEDGE
received. The master terminates the read operation by
not responding with an ACKNOWLEDGE and instead
issuing a STOP condition.
The data output is sequential, with the data from
address n followed by the data from address n + 1. The
address counter for read operations increments through
the entire memory contents to be serially read during
one operation. At the end of the address space the
counter “rolls over” to address 00h and the device continues to output data for each ACKNOWLEDGE
received (Refer to Figure 16.).
A
C
K
A
C
K
A
C
K
S
t
o
p
0 0 01
A
C
K
Signals from
the Slave
Data
(1)
Data
(2)
Data
(n-1)
Data
(n)
(n is any integer greater than 1)
Figure 16. Sequential EEPROM Read Sequence
12
FN8206.0
March 8, 2005
X9520
CS7
CS6
CS5
CS4
CS3
CS2
CS1
CS0
POR1
V2OS
V3OS
BL1
BL0
RWEL
WEL
POR0
NV
NV
NV
Bit(s)
WEL
NV
Description
Write Enable Latch bit
RWEL
Register Write Enable Latch bit
V2OS
V2 Output Status flag
V3OS
V3 Output Status flag
BL1 - BL0
POR1 - POR0
Sets the Block Lock partition
Sets the Power-on Reset time
Writes to the WEL bit do not cause an internal high voltage write cycle. Therefore, the device is ready for
another operation immediately after a STOP condition is
executed in the CONSTAT Write command sequence
(See Figure 18).
RWEL: Register Write Enable Latch (Volatile)
The RWEL bit controls the (CONSTAT) Register Write
Enable status of the X9520. Therefore, in order to write
to any of the bits of the CONSTAT Register (except
WEL), the RWEL bit must first be set to “1”. The RWEL
bit is a volatile bit that powers up in the disabled, LOW
(“0”) state.
It must be noted that the RWEL bit can only be set, once
the WEL bit has first been enabled (See "CONSTAT
Register Write Operation").
NOTE: Bits labelled NV are nonvolatile (See “CONTROL AND STATUS REGISTER”).
Figure 17. CONSTAT Register Format
CONTROL AND STATUS REGISTER
The Control and Status (CONSTAT) Register provides
the user with a mechanism for changing and reading
the status of various parameters of the X9520 (See
Figure 17).
The CONSTAT register is a combination of both volatile
and nonvolatile bits. The nonvolatile bits of the CONSTAT register retain their stored values even when V1 /
Vcc is powered down, then powered back up. The volatile bits however, will always power-up to a known logic
state “0” (irrespective of their value at power-down).
A detailed description of the function of each of the CONSTAT register bits follows:
WEL: Write Enable Latch (Volatile)
The WEL bit controls the Write Enable status of the
entire X9520 device. This bit must first be enabled before
ANY write operation (to DCPs, EEPROM memory array,
or the CONSTAT register). If the WEL bit is not first
enabled, then ANY proceeding (volatile or nonvolatile)
write operation to DCPs, EEPROM array, as well as the
CONSTAT register, is aborted and no ACKNOWLEDGE
is issued after a Data Byte.
The WEL bit is a volatile latch that powers up in the disabled, LOW (0) state. The WEL bit is enabled / set by
writing 00000010 to the CONSTAT register. Once
enabled, the WEL bit remains set to “1” until either it is
reset to “0” (by writing 00000000 to the CONSTAT register) or until the X9520 powers down, and then up again.
13
The RWEL bit will reset itself to the default “0” state, in
one of three cases:
—After a successful write operation to any bits of
the CONSTAT register has been completed (See
Figure 18).
—When the X9520 is powered down.
—When attempting to write to a Block Lock protected
region of the EEPROM memory (See "BL1, BL0: Block
Lock protection bits - (Nonvolatile)", below).
BL1, BL0: Block Lock protection bits - (Nonvolatile)
The Block Lock protection bits (BL1 and BL0) are used
to:
—Inhibit a write operation from being performed to certain addresses of the EEPROM memory array
—Inhibit a DCP write operation (changing the “wiper
position”).
The region of EEPROM memory which is protected /
locked is determined by the combination of the BL1 and
BL0 bits written to the CONSTAT register. It is possible
to lock the regions of EEPROM memory shown in the
table below:
BL1 BL0
Protected Addresses
(Size)
Partition of array
locked
0
0
None (Default)
None (Default)
0
1
C0h - FFh (64 bytes)
Upper 1/4
1
0
80h - FFh (128 bytes)
Upper 1/2
1
1
00h - FFh (256 bytes)
All
If the user attempts to perform a write operation on a protected region of EEPROM memory, the operation is
aborted without changing any data in the array.
FN8206.0
March 8, 2005
X9520
SCL
SDA
S
T
A
R
T
1
0
1
0
0
1
0
R/W A
C
K
SLAVE ADDRESS BYTE
1
1
1
1
1
1
1
1
CS7 CS6 CS5 CS4 CS3 CS2 CS1 CS0
A
C
K
ADDRESS BYTE
CONSTAT REGISTER DATA IN
A
C
K
S
T
O
P
Figure 18. CONSTAT Register Write Command Sequence
When the Block Lock bits of the CONSTAT register are
set to something other than BL1 = 0 and BL0 = 0, then
the “wiper position” of the DCPs cannot be changed - i.e.
DCP write operations cannot be conducted:
BL1
BL0
DCP Write Operation Permissible
0
0
YES (Default)
0
1
NO
1
0
NO
1
1
NO
The nominal Power-on Reset delay time can be selected
from the following table, by writing the appropriate bits to
the CONSTAT register:
POR1
POR0
Power-on Reset delay (tPUV1RO)
0
0
50ms
0
1
100ms (Default)
1
0
200ms
1
1
300ms
The default for these bits are POR1 = 0, POR0 = 1.
The factory default setting for these bits are BL1 = 0,
BL0 = 0.
IMPORTANT NOTE: If the Write Protect (WP) pin of the
X9520 is active (HIGH), then all nonvolatile write operations to both the EEPROM memory and DCPs are inhibited, irrespective of the Block Lock bit settings (See "WP:
Write Protection Pin").
POR1, POR0: Power-on Reset bits – (Nonvolatile)
Applying voltage to VCC activates the Power-on Reset
circuit which holds V1RO output HIGH, until the supply
voltage stabilizes above the VTRIP1 threshold for a
period of time, tPURST (See Figure 30).
The Power-on Reset bits, POR1 and POR0 of the
CONSTAT register determine the tPURST delay time of
the Power-on Reset circuitry (See "VOLTAGE MONITORING FUNCTIONS"). These bits of the CONSTAT
register are nonvolatile, and therefore power-up to the
last written state.
14
V2OS, V3OS: Voltage Monitor Status Bits (Volatile)
Bits V2OS and V3OS of the CONSTAT register are
latched, volatile flag bits which indicate the status of the
Voltage Monitor reset output pins V2RO and V3RO.
At power-up the VxOS (x = 2,3) bits default to the value
“0”. These bits can be set to a “1” by writing the appropriate value to the CONSTAT register. To provide consistency between the VxRO and VxOS however, the status
of the VxOS bits can only be set to a “1” when the corresponding VxRO output is HIGH.
Once the VxOS bits have been set to “1”, they will be
reset to “0” if:
—The device is powered down, then back up,
—The corresponding VxRO output becomes LOW.
FN8206.0
March 8, 2005
X9520
CONSTAT Register Write Operation
The CONSTAT register is accessed using the Slave
Address set to 1010010 (Refer to Figure 4.). Following
the Slave Address Byte, access to the CONSTAT register requires an Address Byte which must be set to FFh.
Only one data byte is allowed to be written for each
CONSTAT register Write operation. The user must issue
a STOP, after sending this byte to the register, to initiate
the nonvolatile cycle that stores the BP1, BP0, POR1
and POR0 bits. The X9520 will not ACKNOWLEDGE
any data bytes written after the first byte is entered (Refer
to Figure 18.).
Prior to writing to the CONSTAT register, the WEL and
RWEL bits must be set using a two step process, with
the whole sequence requiring 3 steps
—Write a 02H to the CONSTAT Register to set the Write
Enable Latch (WEL). This is a volatile operation, so
there is no delay after the write. (Operation preceded
by a START and ended with a STOP).
—Write a 06H to the CONSTAT Register to set the Register Write Enable Latch (RWEL) AND the WEL bit.
This is also a volatile cycle. The zeros in the data byte
are required. (Operation preceded by a START and
ended with a STOP).
—Write a one byte value to the CONSTAT Register that
has all the bits set to the desired state. The CONSTAT
register can be represented as qxyst01r in binary,
where xy are the Voltage Monitor Output Status
(V2OS and V3OS) bits, st are the Block Lock Protection (BL1 and BL0) bits, and qr are the Power-on Reset
delay time (tPUV1RO) control bits (POR1 - POR0).
S
t
a
r
t
Signals from
the Master
SDA Bus
This operation is proceeded by a START and ended
with a STOP bit. Since this is a nonvolatile write cycle,
it will typically take 5ms to complete. The RWEL bit is
reset by this cycle and the sequence must be repeated
to change the nonvolatile bits again. If bit 2 is set to ‘1’
in this third step (qxys t11r) then the RWEL bit is set,
but the V2OS, V3OS, POR1, POR0, BL1 and BL0 bits
remain unchanged. Writing a second byte to the control register is not allowed. Doing so aborts the write
operation and the X9520 does not return an
ACKNOWLEDGE.
For example, a sequence of writes to the device CONSTAT register consisting of [02H, 06H, 02H] will reset all
of the nonvolatile bits in the CONSTAT Register to “0”.
It should be noted that a write to any nonvolatile bit of
CONSTAT register will be ignored if the Write Protect
pin of the X9520 is active (HIGH) (See "WP: Write Protection Pin").
CONSTAT Register Read Operation
The contents of the CONSTAT Register can be read at
any time by performing a random read (See Figure 19).
Using the Slave Address Byte set to 10100101, and an
Address Byte of FFh. Only one byte is read by each register read operation. The X9520 resets itself after the first
byte is read. The master should supply a STOP condition
to be consistent with the bus protocol.
After setting the WEL and / or the RWEL bit(s) to a “1”,
a CONSTAT register read operation may occur, without
interrupting a proceeding CONSTAT register write
operation.
READ Operation
WRITE Operation
Slave
Address
S
t
Slave
a
r Address
t
Address
Byte
CS7 … CS0
1 0 1 0 0 1 01
10 1 0 0 1 0 0
A
C
K
Signals from
the Slave
S
t
o
p
A
C
K
A
C
K
Data
“Dummy” Write
Figure 19. CONSTAT Register Read Command Sequence
15
FN8206.0
March 8, 2005
X9520
DATA PROTECTION
There are a number of levels of data protection features
designed into the X9520. Any write to the device first
requires setting of the WEL bit in the CONSTAT register.
A write to the CONSTAT register itself, further requires
the setting of the RWEL bit. Block Lock protection of the
device enables the user to inhibit writes to certain regions
of the EEPROM memory, as well as to all the DCPs. One
further level of data protection in the X9520, is incorporated in the form of the Write Protection pin.
V1 / Vcc
VTRIP1
0 Volts
MR
V1RO
0 Volts
0 Volts
tPURST
WP: Write Protection Pin
When the Write Protection (WP) pin is active (HIGH), it
disables nonvolatile write operations to the X9520.
The table below (X9520 Write Permission Status) summarizes the effect of the WP pin (and Block Lock), on the
write permission status of the device.
Additional Data Protection Features
In addition to the preceding features, the X9520 also
incorporates the following data protection functionality:
—The proper clock count and data bit sequence is
required prior to the STOP bit in order to start a nonvolatile write cycle.
Figure 20. Manual Reset Response
For the Power-on / Low Voltage Reset function of the
X9520, the V1RO output may be driven HIGH down to a
V1 / Vcc of 1V (VRVALID). See Figure 30. Another feature of the X9520, is that the value of tPURST may be
selected in software via the CONSTAT register (See
“POR1, POR0: Power-on Reset bits – (Nonvolatile)” on
page 14.).
It is recommended to stop communication to the device
while V1R0 is HIGH. Also, setting the Manual Reset
(MR) pin HIGH overrides the Power-on / Low Voltage circuitry and forces the V1RO output pin HIGH (See "MR:
Manual Reset").
VOLTAGE MONITORING FUNCTIONS
MR: Manual Reset
V1 / Vcc Monitoring
The X9520 monitors the supply voltage and drives the
V1RO output HIGH (using an external “pull up” resistor)
if V1 / Vcc is lower than VTRIP1 threshold. The V1RO
output will remain HIGH until V1 / Vcc exceeds VTRIP1
for a minimum time of tPURST. After this time, the
V1RO pin is driven to a LOW state. See Figure 30.
The V1RO output can be forced HIGH externally using
the Manual Reset (MR) input. MR is a de-bounced, TTL
compatible input, and so it may be operated by connecting a push-button directly from V1 / Vcc to the MR pin.
V1RO remains HIGH for time tPURST after MR has
returned to its LOW state (See Figure 20). An external
“pull down” resistor is required to hold this pin (normally) LOW.
X9520 Write Permission Status
Block Lock
Bits
Write to CONSTAT Register
Permitted
BL1
WP
DCP Volatile Write
Permitted
DCP Nonvolatile
Write Permitted
Write to EEPROM
Permitted
Volatile Bits
Nonvolatile
Bits
x
1
1
NO
NO
NO
NO
NO
1
x
1
NO
NO
NO
NO
NO
0
0
1
YES
NO
NO
NO
NO
x
1
0
NO
NO
Not in locked region
YES
YES
1
x
0
NO
NO
Not in locked region
YES
YES
0
0
0
YES
YES
Yes (All Array)
YES
YES
BL0
16
FN8206.0
March 8, 2005
X9520
V2 Monitoring
The X9520 asserts the V2RO output HIGH if the voltage V2 exceeds the corresponding VTRIP2 threshold
(See Figure 21). The bit V2OS in the CONSTAT register is then set to a “0” (assuming that it has been set to
“1” after system initilization).
VTRIPx
Vx
0V
VxRO
0V
The V2RO output may remain active HIGH with VCC
down to 1V.
V1 / Vcc
V3 Monitoring
VTRIP1
0 Volts
The X9520 asserts the V3RO output HIGH if the voltage V3 exceeds the corresponding VTRIP3 threshold
(See Figure 21). The bit V3OS in the CONSTAT register is then set to a “0” (assuming that it has been set to
“1” after system initilization).
(x = 2,3)
Figure 21. Voltage Monitor Response
directly into the VTRIPx cell. If however, the new setting is to be lower than the present setting, then it is
necessary to “reset” the VTRIPx voltage before setting
the new value.
The V3RO output may remain active HIGH with VCC
down to 1V.
VTRIPX THRESHOLDS (X=1,2,3)
The X9520 is shipped with pre-programmed threshold
(VTRIPx) voltages. In applications where the required
thresholds are different from the default values, or if a
higher precision / tolerance is required, the X9520 trip
points may be adjusted by the user, using the steps
detailed below.
Setting a Higher VTRIPx Voltage (x=1,2,3)
To set a VTRIPx threshold to a new voltage which is
higher than the present threshold, the user must apply
the desired VTRIPx threshold voltage to the corresponding input pin (V1 / Vcc, V2 or V3). Then, a programming voltage (Vp) must be applied to the WP pin
before a START condition is set up on SDA. Next, issue
on the SDA pin the Slave Address A0h, followed by
the Byte Address 01h for VTRIP1, 09h for VTRIP2, and
0Dh for VTRIP3, and a 00h Data Byte in order to program VTRIPx. The STOP bit following a valid write
operation initiates the programming sequence. Pin WP
must then be brought LOW to complete the operation
Setting a VTRIPx Voltage (x=1,2,3)
There are two procedures used to set the threshold
voltages (VTRIPx), depending if the threshold voltage
to be stored is higher or lower than the present value.
For example, if the present VTRIPx is 2.9 V and the
new VTRIPx is 3.2 V, the new voltage can be stored
VTRIPx
V1 / Vcc
V2, V3
VP
WP
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
SCL
00h
SDA
A0h
S
T
A
R
T
†
†
†
09h sets VTRIP2
†
0Dh sets V
01h sets VTRIP1
Data Byte †
TRIP3
† All others Reserved.
Figure 22. Setting VTRIPx to a higher level (x=1,2,3).
17
FN8206.0
March 8, 2005
X9520
(See Figure 23). The user does not have to set the
WEL bit in the CONSTAT register before performing
this write sequence.
If the desired threshold is less that the present threshold
voltage, then it must first be “reset” (See "Resetting the
VTRIPx Voltage (x=1,2,3).").
Setting a Lower VTRIPx Voltage (x=1,2,3).
The desired threshold voltage is then applied to the
appropriate input pin (V1 / Vcc, V2 or V3) and the procedure described in Section “Setting a Higher VTRIPx
Voltage“ must be followed.
In order to set VTRIPx to a lower voltage than the
present value, then VTRIPx must first be “reset”
according to the procedure described below. Once
VTRIPx has been “reset”, then VTRIPx can be set to
the desired voltage using the procedure described in
“Setting a Higher VTRIPx Voltage”.
Resetting the VTRIPx Voltage (x=1,2,3).
To reset a VTRIPx voltage, apply the programming
voltage (Vp) to the WP pin before a START condition is
set up on SDA. Next, issue on the SDA pin the Slave
Address A0h followed by the Byte Address 03h for
VTRIP1, 0Bh for VTRIP2, and 0Fh for VTRIP3, followed
by 00h for the Data Byte in order to reset VTRIPx. The
STOP bit following a valid write operation initiates the
programming sequence. Pin WP must then be brought
LOW to complete the operation (See Figure 23).The
user does not have to set the WEL bit in the CONSTAT register before performing this write sequence.
After being reset, the value of VTRIPx becomes a nominal value of 1.7V.
VTRIPx Accuracy (x=1,2,3).
The accuracy with which the VTRIPx thresholds are set,
can be controlled using the iterative process shown in
Figure 24.
Once the desired VTRIPx threshold has been set, the
error between the desired and (new) actual set threshold
can be determined. This is achieved by applying V1 / Vcc
to the device, and then applying a test voltage higher
than the desired threshold voltage, to the input pin of the
voltage monitor circuit whose VTRIPx was programmed.
For example, if VTRIP2 was set to a desired level of 3.0
V, then a test voltage of 3.4 V may be applied to the voltage monitor input pin V2. In the case of setting of VTRIP1
then only V1 / Vcc need be applied. In all cases, care
should be taken not to exceed the maximum input voltage limits.
After applying the test voltage to the voltage monitor
input pin, the test voltage can be decreased (either in discrete steps, or continuously) until the output of the voltage monitor circuit changes state. At this point, the error
between the actual / measured, and desired threshold
levels is calculated.
For example, the desired threshold for VTRIP2 is set to
3.0 V, and a test voltage of 3.4 V was applied to the input
pin V2 (after applying power to V1 / Vcc). The input voltage is decreased, and found to trip the associated output
level of pin V2RO from a LOW to a HIGH, when V2
reaches 3.09 V. From this, it can be calculated that the
programming error is 3.09 - 3.0 = 0.09 V.
VP
WP
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
SCL
00h †
SDA
A0h†
S
T
A
R
T
†
†
0Bh Resets VTRIP2
†
0Fh Resets VTRIP3
03h Resets VTRIP1
Data Byte
Figure 23. Resetting the VTRIPx Level
18
† All others Reserved.
FN8206.0
March 8, 2005
X9520
If the error between the desired and measured VTRIPx is
less than the maximum desired error, then the programming process may be terminated. If however, the error is
greater than the maximum desired error, then another
iteration of the VTRIPx programming sequence can be
performed (using the calculated error) in order to further
increase the accuracy of the threshold voltage.
Continuing the previous example, we see that the calculated error was 0.09V. Since this is greater than zero, we
must first “reset” the VTRIP2 threshold, then apply a voltage equal to the last previously programmed voltage,
minus the last previously calculated error. Therefore, we
must apply VTRIP2 = 2.91 V to pin V2 and execute the
programming sequence ( ) .
If the calculated error is greater than zero, then the
VTRIPx must first be “reset”, and then programmed to the
a value equal to the previously set VTRIPx minus the calculated error. If it is the case that the error is less than
zero, then the VTRIPx must be programmed to a value
equal to the previously set VTRIPx plus the absolute
value of the calculated error.
Using this process, the desired accuracy for a particular VTRIPx threshold may be attained using a successive number of iterations.
Note: X = 1,2,3.
VTRIPx Programming
NO
Let: MDE = Maximum Desired Error
MDE+
Desired VTRIPx <
present value?
Desired Value
Acceptable
Error Range
MDE–
YES
Execute
VTRIPx Reset
Sequence
Error = Actual - Desired
Set Vx = desired VTRIPx
Execute
Set Higher VTRIPx
Sequence
New Vx applied =
Old Vx applied + | Error |
New Vx applied =
Old Vx applied - | Error |
Execute
Reset VTRIPx
Sequence
Apply Vcc & Voltage
> Desired VTRIPx to Vx
Decrease Vx
NO
Output
switches?
YES
Error < MDE–
Actual VTRIPx
- Desired VTRIPx
Error >MDE+
= Error
| Error | < | MDE |
DONE
Figure 24. VTRIPx Setting / Reset Sequence (x=1,2,3)
19
FN8206.0
March 8, 2005
X9520
ABSOLUTE MAXIMUM RATINGS
Parameter
Temperature under Bias
Storage Temperature
Voltage on WP pin (With respect to Vss)
Voltage on other pins (With respect to Vss)
| Voltage on RHx– Voltage on RLx | (x = 0,1,2. Referenced to Vss)
D.C. Output Current (SDA,V1RO,V2RO,V3RO)
Lead Temperature (Soldering, 10 seconds)
Supply Voltage Limits (Applied V1 / Vcc voltage, referenced to Vss)
Min.
Max.
Units
-65
-65
-1.0
-1.0
+135
+150
+15
+7
V1 / Vcc
5
300
5.5
°C
°C
V
V
V
mA
°C
V
0
2.7
RECOMMENDED OPERATING CONDITIONS
Temperature
Industrial
Min.
Max.
Units
-40
+85
°C
NOTE: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only and the functional operation of the device at these or any other conditions above those listed in the
operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 25. Equivalent A.C. Circuit
V1 / Vcc = 5V
2300Ω
SDA
V2RO
V3RO
V1RO
100pF
Figure 26. DCP SPICE Macromodel
RTOTAL
RHx
CH
CL
RW
RLx
10pF
CW
10pF
25pF
(x = 0,1,2)
RWx
20
FN8206.0
March 8, 2005
X9520
TIMING DIAGRAMS
Figure 27. Bus Timing
tHIGH
tF
SCL
tLOW
tR
tSU:DAT
tSU:STA
tHD:DAT
tHD:STA
SDA IN
tSU:STO
tA
tDH
tBUF
SDA OUT
Figure 28. WP Pin Timing
START
SCL
Clk 1
Clk 9
SDA IN
tSU:WP
WP
tHD:WP
Figure 29. Write Cycle Timing
SCL
SDA
8th bit of last byte
ACK
tWC
Stop
Condition
21
Start
Condition
FN8206.0
March 8, 2005
X9520
Figure 30. Power-Up and Power-Down Timing
t
tF
R
V1 / Vcc
V TRIP1
0 Volts
t
t
PURST
PURST
tRPD
tRPD
V1RO
0 Volts
MR
0 Volts
Figure 31. Manual Reset Timing Diagram
MR
tMRPW
0 Volts
t
tMRD
V1RO
PURST
0 Volts
V1 / Vcc
V1 / Vcc
V TRIP1
Figure 32. V2, V3 Timing Diagram
t
tFx
Rx
Vx
V TRIPx
tRPDx
tRPDx
tRPDx
0 Volts
tRPDx
VxRO
0 Volts
V1 / Vcc
V TRIP1
V
RVALID
0 Volts
Note : x = 2,3.
22
FN8206.0
March 8, 2005
X9520
Figure 33. VTRIPX Programming Timing Diagram (x=1,2,3).
V1 / Vcc, V2, V3
VTRIPx
tTSU
tTHD
VP
WP
tVPS
tVPO
SCL
twc
00h
SDA
NOTE : V1/Vcc must be greater than V2, V3 when programming.
tVPH
Figure 34. DCP “Wiper Position” Timing
Rwx (x = 0,1,2)
Rwx(n+1)
Rwx(n)
Rwx(n-1)
twr
Time
n = tap position
SCL
SDA
S 1
T
A
R
T
0
1
0
1
1
1
SLAVE ADDRESS BYTE
23
0
A WT
C
K
0
0
0
0
0
INSTRUCTION BYTE
P1 P0
A
C
K
D7 D6 D5 D4 D3 D2 D1 D0
DATA BYTE
A
C
K
S
T
O
P
FN8206.0
March 8, 2005
X9520
D.C. OPERATING CHARACTERISTICS
Symbol
Parameter
Min
Typ
Max
Unit
Test Conditions / Notes
0.4
1.5
mA
fSCL = 400kHz
µA
VSDA = VCC
MR = Vss
WP = Vss or Open/Floating
VSCL= VCC (when no bus
activity else fSCL = 400kHz)
10
µA
VIN (4) = GND to VCC.
10
µA
1
10
µA
0.1
10
µA
Current into VCC Pin
(X9520: Active)
Read memory array (3)
Write nonvolatile memory
ICC1(1)
Current into VCC Pin
(X9520:Standby)
With 2-Wire bus activity (3)
No 2-Wire bus activity
ICC2(2)
ILI
50
50
Input Leakage Current (SCL, SDA, MR)
0.1
Input Leakage Current (WP)
VIN = VSS to VCC with all other
analog inputs floating
Iai
Analog Input Leakage
ILO
Output Leakage Current (SDA, V1RO,
V2RO, V3RO)
VTRIP1PR
VTRIP1 Programming Range
2.75
4.70
V
VTRIPxPR
VTRIPx Programming Range (x=2,3)
1.8
4.70
V
VTRIP1 (6)
Pre - programmed VTRIP1 threshold
2.85
4.55
3.0
4.7
3.05
4.75
V
Factory shipped default option A
Factory shipped default option B
VTRIP2 (6)
Pre - programmed VTRIP2 threshold
1.65
2.85
1.8
3.0
1.85
3.05
V
Factory shipped default option A
Factory shipped default option B
VTRIP3 (6)
Pre - programmed VTRIP3 threshold
1.65
2.85
1.8
3.0
1.85
3.05
V
Factory shipped default option A
Factory shipped default option B
IVx
V2 Input leakage current
V3 Input leakage current
1
1
µA
VIL (7)
Input LOW Voltage (SCL, SDA, WP, MR)
-0.5
0.8
V
VIH (7)
Input HIGH Voltage (SCL,SDA, WP, MR)
2.0
VCC
+0.5
V
VOLx
V1RO, V2RO, V3RO, SDA Output Low
Voltage
0.4
V
VOUT (5) = GND to VCC.
X9520 is in Standby(2)
VSDA = VSCL = VCC
Others=GND or VCC
ISINK = 2.0mA
Notes: 1. The device enters the Active state after any START, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave
Address Byte are incorrect; 200nS after a STOP ending a read operation; or tWC after a STOP ending a write operation.
Notes: 2. The device goes into Standby: 200nS after any STOP, except those that initiate a high voltage write cycle; tWC after a STOP that initiates a high voltage cycle; or 9 clock cycles after any START that is not followed by the correct Device Select Bits in the Slave Address
Byte.
Notes: 3. Current through external pull up resistor not included.
Notes: 4. VIN = Voltage applied to input pin.
Notes: 5. VOUT = Voltage applied to output pin.
Notes: 6. See “ORDERING INFORMATION” on page 33.
Notes: 7. VIL Min. and VIH Max. are for reference only and are not tested
24
FN8206.0
March 8, 2005
X9520
A.C. CHARACTERISTICS (See Figure 27, Figure 28, Figure 29)
400kHz
Symbol
Min
Max
Units
SCL Clock Frequency
0
400
kHz
tIN (5)
Pulse width Suppression Time at inputs
50
tAA (5)
SCL LOW to SDA Data Out Valid
0.1
tBUF
Time the bus free before start of new transmission
1.3
µs
tLOW
Clock LOW Time
1.3
µs
tHIGH
Clock HIGH Time
0.6
µs
tSU:STA
Start Condition Setup Time
0.6
µs
tHD:STA
Start Condition Hold Time
0.6
µs
tSU:DAT
Data In Setup Time
100
ns
tHD:DAT
Data In Hold Time
0
µs
tSU:STO
Stop Condition Setup Time
0.6
µs
Data Output Hold Time
50
ns
fSCL
tDH
(5)
Parameter
ns
µs
0.9
tR (5)
SDA and SCL Rise Time
20 +.1Cb (2)
300
ns
tF (5)
SDA and SCL Fall Time
20 +.1Cb (2)
300
ns
tSU:WP
WP Setup Time
0.6
µs
tHD:WP
WP Hold Time
0
µs
Cb (5)
Capacitive load for each bus line
400
pF
A.C. TEST CONDITIONS
Input Pulse Levels
0.1VCC to 0.9VCC
Input Rise and Fall Times
10ns
Input and Output Timing Levels
0.5VCC
Output Load
See Figure 25
NONVOLATILE WRITE CYCLE TIMING
Symbol
tWC(4)
Parameter
Min.
Typ.(1)
Max.
Units
5
10
ms
Nonvolatile Write Cycle Time
CAPACITANCE (TA = 25°C, F = 1.0 MHZ, VCC = 5V)
Symbol
COUT
(5)
CIN (5)
Parameter
Max
Units
Test Conditions
Output Capacitance (SDA, V1RO, V2RO, V3RO)
8
pF
VOUT = 0V
Input Capacitance (SCL, WP, MR)
6
pF
VIN = 0V
Notes: 1. Typical values are for TA = 25°C and VCC = 5.0V
Notes: 2. Cb = total capacitance of one bus line in pF.
Notes: 3. Over recommended operating conditions, unless otherwise specified
Notes: 4. tWC is the time from a valid STOP condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It
is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
Notes: 5. This parameter is not 100% tested.
25
FN8206.0
March 8, 2005
X9520
POTENTIOMETER CHARACTERISTICS
Limits
Symbol
Parameter
Min.
Typ.
Max.
Units
Test Conditions/Notes
RTOL
End to End Resistance Tolerance
-20
+20
%
VRHx
RH Terminal Voltage (x = 0,1,2)
Vss
VCC
V
VRLx
RL Terminal Voltage (x = 0,1,2)
Vss
VCC
V
PR
Power Rating (1)(6)
10
mW
RTOTAL = 10kΩ (DCP0, DCP1)
5
mW
RTOTAL = 100kΩ (DCP2)
200
400
Ω
IW = 1mA, VCC = 5 V,
VRHx = Vcc, VRLx = Vss
(x = 0,1,2).
400
1200
Ω
IW = 1mA, VCC = 2.7 V,
VRHx = Vcc, VRLx = Vss
(x = 0,1,2)
4.4
mA
RW
IW
DCP Wiper Resistance
Wiper Current (6)
Noise
mV/
sqt(Hz)
RTOTAL = 10kΩ (DCP0, DCP1)
mV/
sqt(Hz)
RTOTAL = 100kΩ (DCP2)
Absolute Linearity (2)
-1
+1
MI(4)
Rw(n)(actual) - Rw(n)(expected)
Relative Linearity (3)
-1
+1
MI(4)
Rw(n+1) - [Rw(n)+MI]
RTOTAL Temperature Coefficient
CH/CL/CW
Potentiometer Capacitances (6)
twr
Wiper Response time (6)
±300
ppm/°C
RTOTAL = 10kΩ (DCP0, DCP1)
±300
ppm/°C
RTOTAL = 100kΩ (DCP2)
pF
10/10/25
200
µs
See Figure 26.
See Figure 34.
Notes: 1. Power Rating between the wiper terminal RWX(n) and the end terminals RHX or RLX - for ANY tap position n, (x = 0,1,2).
Notes: 2. Absolute Linearity is utilized to determine actual wiper resistance versus, expected resistance = (Rwx(n)(actual) - Rwx(n)(expected)) = ±1
Ml Maximum (x = 0,1,2).
Notes: 3. Relative Linearity is a measure of the error in step size between taps = RWx(n+1) - [Rwx(n) + Ml] = ±1 Ml (x = 0,1,2)
Notes: 4. 1 Ml = Minimum Increment = RTOT / (Number of taps in DCP - 1).
Notes: 5. Typical values are for TA = 25°C and nominal supply voltage.
Notes: 6. This parameter is periodically sampled and not 100% tested.
26
FN8206.0
March 8, 2005
X9520
VTRIPX (X=1,2,3) PROGRAMMING PARAMETERS (See Figure 33)
Parameter
Description
Min
Typ
Max
Units
tVPS
VTRIPx Program Enable Voltage Setup time
10
µs
tVPH
VTRIPx Program Enable Voltage Hold time
10
µs
tTSU
VTRIPx Setup time
10
µs
tTHD
VTRIPx Hold (stable) time
10
µs
tVPO
VTRIPx Program Enable Voltage Off time
(Between successive adjustments)
1
ms
twc
VTRIPx Write Cycle time
VP
Programming Voltage
Vta
Vtv
Notes:
5
VTRIPx Program Voltage accuracy
(Programmed at 25oC.)
VTRIP Program variation after programming (-40 - 85oC).
10
ms
10
15
V
-100
+100
mV
-25
+10
+25
mV
Condition
Min.
Typ.
Max.
Units
POR1 = 0, POR0 = 0
25
50
75
ms
POR1 = 0, POR0 = 1
50
100
150
ms
POR1 = 1, POR0 = 0
100
200
300
ms
POR1 = 1, POR0 = 1
150
300
450
ms
5
µs
(Programmed at 25oC.)
The above parameters are not 100% tested.
V1RO, V2RO, V3RO OUTPUT TIMING. (See Figure 30, Figure 31, Figure 32)
Symbol
tPURST (5)
tMRD
(31)(2)(5)
Description
Power On Reset delay time
MR to V1RO propagation delay
See (1)(2)(4)
tMRDPW(5)
MR pulse width
tRPDx (5)
V1 / Vcc, V2, V3 to V1RO,
V2RO, V3RO propagation
delay (respectively)
tFx (5)
V1 / Vcc, V2, V3 Fall Time
20
mV/µs
tRx (5)
V1 / Vcc, V2, V3 Rise Time
20
mV/µs
VRVALID (5)
V1 / Vcc for V1RO, V2RO,
V3RO Valid (3).
1
V
500
ns
20
µs
Notes: 1. See Figure 31 for timing diagram.
Notes: 2. See Figure 25 for equivalent load.
Notes: 3. This parameter describes the lowest possible V1 / Vcc level for which the outputs V1RO, V2RO, and V3RO will be correct with respect to
their inputs (V1 / Vcc, V2, V3).
Notes: 4. From MR rising edge crossing VIH, to V1RO rising edge crossing VOH.
Notes: 5. The above parameters are not 100% tested.
27
FN8206.0
March 8, 2005
X9520
APPENDIX 1
DCP1 (100 Tap) Tap position to Data Byte translation Table
Data Byte
Tap
Position
Decimal
Binary
0
0
0000 0000
1
1
0000 0001
.
.
.
.
.
.
23
23
0001 0111
24
24
0001 1000
25
56
0011 1000
26
55
0011 0111
.
.
.
.
.
.
48
33
0010 0001
49
32
0010 0000
50
64
0100 0000
51
65
0100 0001
.
.
.
.
.
.
73
87
0101 0111
74
88
0101 1000
75
120
0111 1000
76
119
0111 0111
.
.
.
.
.
.
98
97
0110 0001
99
96
0110 0000
28
FN8206.0
March 8, 2005
X9520
APPENDIX 2
DCP1 (100 Tap) tap position to Data Byte translation algorithm example. (Example 1)
unsigned
{
int
int
int
int
DCP1_TAP_Position(int tap_pos)
block;
i;
offset;
wcr_val;
offset= 0;
block = tap_pos / 25;
if (block < 0) return ((unsigned)0);
else if (block <= 3)
{
switch(block)
{
case (0): return ((unsigned)tap_pos) ;
case (1):
{
wcr_val = 56;
offset = tap_pos - 25;
for (i=0; i<= offset; i++) wcr_val-- ;
return ((unsigned)++wcr_val);
}
case (2):
{
wcr_val = 64;
offset = tap_pos - 50;
for (i=0; i<= offset; i++) wcr_val++ ;
return ((unsigned)--wcr_val);
}
case (3):
{
wcr_val = 120;
offset = tap_pos - 75;
for (i=0; i<= offset; i++) wcr_val-- ;
return ((unsigned)++wcr_val);
}
}
}
}
return((unsigned)01100000);
29
FN8206.0
March 8, 2005
X9520
APPENDIX 2
DCP1 (100 Tap) tap position to Data Byte translation algorithm example. (Example 2)
unsigned DCP100_TAP_Position(int tap_pos)
{
/* optional range checking
*/ if (tap_pos < 0) return ((unsigned)0);
else if (tap_pos >99) return ((unsigned) 96);
/* set to min val */
/* set to max val */
/* 100 Tap DCP encoding formula */
if (tap_pos > 74)
return ((unsigned) (195 - tap_pos));
else if (tap_pos > 49)
return ((unsigned) (14 + tap_pos));
else if (tap_pos > 24)
return ((unsigned) (81 - tap_pos));
else return (tap_pos);
}
30
FN8206.0
March 8, 2005
X9520
20-Bump Chip Scale Package (CSP B20)
Package Outline Drawing
a
9520RR
YWW IA
LOT #
f
d
A4
A3
A2
A1
B4
B3
B2
B1
C4
C3
C2
C1
D4
D3
D2
D1
E4
E3
E2
E1
b
j
m
l
Top View (Marking Side)
e
k
Bottom View (Bumped Side)
Side View
e
c
Side View
Package Dimensions
Ball Matrix:
Millimeters
Min
Nominal
Max
Package Width
a
2.542
2.572
2.602
Package Length
b
3.812
3.842
3.872
Package Height
c
0.644
0.677
0.710
Body Thickness
d
0.444
0.457
0.470
Ball Height
e
0.220
0.240
0.260
Ball Diameter
f
0.310
0.330
0.350
Ball Pitch – Width
j
Ball Pitch – Length
k
Ball to Edge Spacing – Width
l
0.511
0.536
0.561
Ball to Edge Spacing – Length
m
0.896
0.921
0.946
31
4
3
A
RL2
B
V3
C
WP
Inches
Symbol
Min
Nominal
Max
2
1
RW2
Vcc
V2RO
RH2
V1RO
V2
V3RO
RL0
RW0
D
SCL
MR
RH0
RH1
E
SDA
RL1
RW1
Vss
0.5
0.5
FN8206.0
March 8, 2005
X9520
PACKAGING INFORMATION
20-LEAD PLASTIC, TSSOP PACKAGE TYPE V
.025 (.65) BSC
.169 (4.3)
.252 (6.4) BSC
.177 (4.5)
.252 (6.4)
.260 (6.6)
.047 (1.20)
.0075 (.19)
.0118 (.30)
.002 (.05)
.006 (.15)
(4.16) (7.72)
.010 (.25)
Gage Plane
0° - 8 °
Seating Plane
.019 (.50)
.029 (.75)
(1.78)
(0.42)
Detail A (20X)
(0.65)
ALL MEASUREMENTS ARE TYPICAL
.031 (.80)
.041 (1.05)
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
32
FN8206.0
March 8, 2005
X9520
ORDERING INFORMATION
X9520
P
T
- y
Preset (Factory Shipped) VTRIPx Threshold Levels (x=1,2,3)
A = Optimized for 3.3 V system monitoring †
B = Optimized for 5 V system monitoring †
Device
Temperature Range
I = Industrial -40°C to +85°C
Package
V20 = 20-Lead TSSOP
B20 = 20-Lead CSP
† For details of preset threshold values, See "D.C. OPERATING CHARACTERISTICS"
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
33
FN8206.0
March 8, 2005