Sync n Go Flyer

Introducing Abracon’s Sync’n-Go
10 MHZ Portable Precision-Frequency-Reference
Most professional test and measurement equipment offering high accuracy and precision; has an input for an
external 10MHz frequency reference. Test Labs and Design facilities often have their 10MHz reference signals
distributed from a common standard, or they have bulky bench devices, which makes them unsuitable for
portable use.
ABRACON offers a pocket-size portable solution – SYNC-n-Go
How it Works….
Ensure that the Sync’n-Go is charged via the mini USB
connectorized wall charger Synchronize the Sync’n Go’s
internal Stratum-III oscillator to a more accurate
reference (e.g. GPSDO, Rubidium standard, etc.) at the
push of a button.
To Sync the device up to an external reference, the
reference signal must be connected to the ‘Ref In’
connector. Next, press the ‘Synchronize’ button.
If the reference signal is stable, the Sync’n Go will
synchronize, and the ‘Lock’ LED will turn yellow then
• Standalone precision 10MHz Synchronized reference green & then turn itself off indicating that the Sync-n-Go
• Fully automated synchronization to an external
is now locked to the external reference.
reference at the press of a button.
• Excellent Portability - 89 x 36mm for bench or field In case the LED starts to flash red, the Sync’n Go could
• Very low Phase Noise
not synchronize to the external signal, due to excessive
(-122dBc/Hz at 100Hz offset),< -160dBc/Hz floor
jitter or incorrect input frequency (other than 10MHz).
• Frequency drift < +/-25ppb over (25°C +/-10°C)
• Typical stability <+/-100ppb over (0°C to +60°C)
Connect the ‘Out’ SMA connector to your test
• LED’s for lock, battery status and output
equipment or measurement system and press the
• Typical 8dBm Sine wave O/P (min 6dBm).
‘power’ button and the ‘On’ LED will turn green
• 10 hour minimum standalone operation
indicating 10MHz reference is available.
• Rechargeable via mini USB connector from PC
or charger
Watch more about Sync’n-Go on YouTube
• Robust construction (Machined Aluminium Enclosure)
www.youtube.com/user/AbraconCorp
Key Features:
Typical Phase Noise @ Offset from Carrier
1Hz offset
-60dBcHz
10Hz offset
-93dBc/Hz
100Hz offset
-122dBc/Hz
1KHz offset
-143dBc/Hz
10KHz offset
-153dBc/Hz
1MHz offset
-157dBc/Hz
5MHz offset
-162dBc/Hz
Applications:
• Mobile testing – Reference for mobile equipment
• Convenient hand-held reference when 10MHz
standards locally unavailable
• Field reference for testing at remote sites
• Very low phase noise reference for in-circuit
bench testing
Links and Resources:
http://www.abracon.com/Precisiontiming/SYNC-10MHz.pdf
In-Stock @: Farnell & Abracon.