Прекъ�вачи ни�ко напрежение Emax2

www.abb.com
The data and illustrations are not binding. We reserve
the right to modify the contents of this document on the
basis of technical development of the products, without
prior notice.
Copyright 2013 ABB. All rights reserved.
1SDC200023D0201 - 03/2013 - 6.000 - CAL - Preliminary
ABB SACE
A division of ABB S.p.A.
L.V. Breakers
Via Baioni, 35
24123 Bergamo
Phone: +39 035 395.111
Fax: +39 035 395.306-433
SACE Emax 2. New low voltage air circuit-breakers
Contact us
Technical catalogue - Edition 03.2013 - Preliminary
Technical cat. | Ed. 03.2013 | Preliminary
SACE Emax 2
New low voltage air circuit-breakers
Index
Main characteristics
1
The ranges
2
Protection trip units
3
Communication devices and systems
4
Accessories
5
Installation
6
Overall dimensions
7
Wiring diagrams
8
Ordering codes
9
ABB catalogue | 1SDC200023D0201 | 0/1
Emax2_cap01.indd 1
12/04/2013 13:52:56
SACE Emax 2
Consultation guide
Chapter 1
Main characteristics
Overview of the SACE Emax 2 family,
distinctive features of the series,
product conformity and service.
Chapter 5
Accessories
Accessories for SACE Emax 2 circuitbreakers (signaling, control, interlocks,
etc..) and for Ekip protection trip
units (connectivity, measurements,
protection, etc).
Chapter 2
The ranges
Electrical characteristics of automatic
circuit-breakers, switch-disconnectors
and derived versions.
Chapter 6
Installation
Installation and circuit-breaker
performance in switchgear, installation
environment, degree of protection and
limiting curves.
Chapter 3
Protection trip units
Latest generation Ekip protection trip
units for power distribution, generator
protection and power control.
Chapter 7
Overall dimensions
Overall dimensions for fixed circuitbreakers, withdrawable circuit-breakers
and accessories.
Chapter 4
Communication devices and systems
Supervision, Energy Management and
complete integration in the systems with
the possibility of communicating with all
the main protocols used in the industrial
sector.
Chapter 8
Wiring diagrams
Circuit-breaker and accessories wiring
diagrams.
00000 000 00
Chapter 9
Ordering codes
Ordering codes with configuration
examples.
0/2 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 2
12/04/2013 13:52:57
Main characteristics
Overview of the SACE Emax 2 family
Guide to selection
1/2
1
Distinctive features of the series
Efficiency
1/3
Control
1/4
Connectivity
1/5
Performance
1/6
Ease of use and safety
1/7
Product conformity
Approvals and certifications
1/9
Quality and Sustainability
1/10
ABB SACE Global Service
1/12
ABB catalogue | 1SDC200023D0201 | 1/1
Emax2_cap01.indd 1
12/04/2013 13:52:57
Overview of the SACE Emax 2 family
1
Guide to selection
Ranges available
E1.2
E2.2
E4.2
E6.2
Automatic circuit-breakers @ 690-1150 V AC
•
•
•
•
Switch-disconnectors @ 690-1150 V AC, 1000 V DC
•
Sectionalizing truck
•
•
•
•
•
•
Earthing switch with making capacity
•
•
•
Earthing truck
•
•
•
Automatic circuit-breakers
Icu (440Vac)
Versione
200
X
150
V
100
H
85
S
66
N
50
C
42
B
630
800
1000
1250
1600
2000
2500
3200
4000
5000
6300
E6.2
E4.2
E2.2
E1.2
Switch-disconnectors
Icw (1s)
Version
120
X
100
V
85
H
66
N
50
N
42
B
630
800
1000
1250
1600
2000
2500
3200
4000
5000
6300
E6.2
E4.2
E2.2
E1.2
Protection trip units
Version
Ekip Dip
Ekip Touch
Ekip Hi-Touch
Application
Distribution
Power control
Generators
Protection devices
-
-
Protection devices and Measurements
Protection devices and Measurements
-
Protection devices, Measurements,
Network analyzer
Protection devices, Measurements,
Network analyzer
-
Protection devices and Measurements
Protection devices and Measurements
Protection devices, Measurements,
Network analyzer
Protection devices, Measurements,
Network analyzer
Ekip G Touch
Ekip G Hi-Touch
1/2 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 2
12/04/2013 13:52:57
Distinctive features
SACE Emax 2 is a new series of low voltage air circuit-breakers up to 6300 A.
With the ability to efficiently and simply control electrical installations – from
the traditional to the more complex – with minimum impact, the new SACE
Emax 2 circuit-breakers represent the evolution of a circuit-breaker into a
Power Manager.
1
Efficiency
1SDC200403F001
1SDC200402F001
SACE Emax 2 air circuit-breakers have been designed to manage, with maximum efficiency, all low voltage electrical
installations: from industrial plants, naval applications, traditional and renewable power generation installations to buildings,
shopping centres, data centres and communication networks.
Achieving maximum efficiency of an electrical installation in order to reduce consumption and waste requires intelligent
management of power supplies and energy use. For this reason, the new technologies used in the SACE Emax 2 circuitbreakers allow the productivity and reliability of installations to be optimized, and at the same time, power consumption to be
reduced while fully respecting the environment.
ABB catalogue | 1SDC200023D0201 | 1/3
Emax2_cap01.indd 3
12/04/2013 13:52:58
Distinctive features
Control
The exclusive Power Controller function available on the new SACE Emax 2 circuit-breakers monitors the power managed
by the circuit-breaker, keeping it below the limit set by the user. As a result of this more effective use, the peak of power
consumed can be limited allowing savings on electricity bills.
The Power Controller, patented by ABB, disconnects non-priority utilities, such as electric car charging stations, lighting or
refrigeration units, during the times when consumption limits need to be respected, and connects them again as soon as it is
appropriate. When required, it automatically activates auxiliary power supplies such as generator sets. No monitoring system
is required: it is sufficient to set the required load limit on Emax 2, which can control any circuit-breaker located downstream,
even if it is not equipped with a measurement function. In installations that are already equipped with energy management
systems, the load limit can also be modified remotely.
SACE Emax 2 circuit-breakers are equipped with a new generation of protection trip units that are easy to programme and
read. The Ekip Touch trip units measure power and energy with precision and save the most recent alarms, events and
measurements in order to prevent faults to the installation or trip effectively when necessary. On request, the Network Analyzer
function is also available, which controls the quality of absorbed power in real time and with extreme precision.
In addition, the innovative Ekip Touch and Hi Touch trip units in the G version include all the functions of generator protection
switchgear, offering a safe control solution that is ready to use. No external devices, wiring or inspections are required.
1SDC200405F001
1
1/4 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 4
12/04/2013 13:52:59
Connectivity
1
1SDC200406F001
SACE Emax 2 series circuit-breakers can be integrated perfectly into all automation and energy management systems to
improve productivity and energy consumption and to carry out remote service.
All circuit-breakers can be equipped with communication units available for use with Modbus, Profibus, and DeviceNet
protocols as well as the modern Modbus TCP, Profinet and EtherNet IP protocols. The cartridge-type modules can be easily
installed directly on the terminal box, even at a later date.
Furthermore, the integrated IEC61850 communication module enables connection to automation systems widely used in
medium voltage power distribution to create intelligent networks (Smart Grids).
Accurate measurements of current, voltage, power and energy are all available by means of the communication modules.
The trip units themselves can be used as multimeters that display the measurements available, or the Ekip Multimeter can be
connected in the front of the switchgear without the need for external instruments and bulky transformers.
All circuit-breaker functions are also accessible via the Internet, in complete safety, through the Ekip Link switchgear
supervision system and the Ekip Control Panel operator panel.
The power and auxiliary connections are optimized to simplify connection to the switchgear. The power terminals, which can
be oriented horizontally or vertically, have been designed for the most common busbars, while the push-in connections of the
auxiliaries ensure immediate and safe wiring.
ABB catalogue | 1SDC200023D0201 | 1/5
Emax2_cap01.indd 5
12/04/2013 13:53:00
Distinctive features
1
Performance
The SACE Emax 2 range is made up of 4 sizes: E1.2, E2.2, E4.2 and E6.2 up to 6300A, which enable switchgear of compact
dimensions and high ratings to be built with busbars of reduced length and cross-section.
The protection trip units, auxiliary connections and main accessories are the same throughout the range to simplify design and
installation. Furthermore, the sizes from E2.2 to E6.2 have the same height and depth.
The rating levels are updated and uniform throughout the sizes to meet the demands and needs of today’s installations, from 42kA
to 200kA, and to standardize switchgear projects.
High short-time currents, together with the efficiency of the protection functions, guarantee complete selectivity in all situations.
Accurate design and choice of materials enable optimization of the overall dimensions of the circuit-breaker. In this way switchgear
of compact dimensions can be built and outstanding savings at the same performance can be obtained.
In particular:
– E1.2 offers 1,600A with breaking capacity up to 66kA and withstand current of 50kA for 1 second in an extremely compact
structure. In the three and four pole version, it offers the sturdiness of SACE Emax with reduced dimensions and enables
switchgear of 66kA to be built in units of 400mm, which is indispensable in places where reduced dimensions are essential,
such as naval and offshore installations.
– E2.2 enables in the three pole version ratings of up to 2,500A to be achieved in switchgear with a width of 400mm.
In addition, it provides short-circuit currents up to 100kA and 85kA for 1 second.
– E4.2 is the new 4,000A circuit-breaker designed to withstand high currents with a withstand rating of 100kA for 1 second
without the need for particular precautions.
– E6.2 is the top of the range, with an interrupting rating of 200kA and a structure that allows 6,300A to be reached, even in
complex installation conditions.
1/6 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 6
12/04/2013 13:53:01
Ease of use and safety
1
The entire range is available in fixed and withdrawable versions, with double insulation between the front of the switchgear and
the live parts to ensure operation in complete safety. The circuit-breakers can be powered indifferently from above or below.
All essential information is available in the central area of the front shield and enables immediate identification of the status of
the circuit-breaker: open, closed, ready to close, charged and discharged springs.
Maintenance is simply and safe. Thanks to the new front shield, the main accessories can be frontally accessed without
completely removing it.
The withdrawable circuit-breaker is inserted and removed via dedicated guide rails that simplify movement. The correct
movement from racked-in, test isolated, to racked-out position is guaranteed by a lock in each position. As a further guarantee
of safety, the shutters of the fixed part can be locked from the front when the circuit-breaker is removed. The shutters of the
upper terminals are independent of those of the lower terminals to facilitate checking and maintenance operations.
The Ekip Touch protection trip units are equipped with a large colour touch-screen display which enables safe and intuitive
operation. Furthermore the Ekip units can be programmed and consulted from a tablet, smart phone or portable PC via
the Ekip Connect application, which allows the parameters of the safety devices calculated in the DOC software to be set
automatically.
1SDC200407F001
The trip units are easily interchangeable from the front of the circuit-breaker, and all communication units can be installed
directly on the terminal box with a few simple operations.
ABB catalogue | 1SDC200023D0201 | 1/7
Emax2_cap01.indd 7
12/04/2013 13:53:01
Distinctive features
1
2
1
3
4
9
5
7
8
10
1SDC200402F001
6
Key
1 Trademark and size of circuit- breaker
2 SACE Ekip protection trip unit
3 Pushbutton for manual opening
4 Pushbutton for manual closing
5 Lever to manually charge closing springs
6 Electrical rating plate
7 Mechanical device to signal circuit-breaker open “O” and closed “I”
8 Signal for springs charged or discharged
9 Mechanical signalling of overcurrent release tripped
10 Size and serial number
1/8 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 8
12/04/2013 13:53:02
Product conformity
SACE Emax 2 circuit-breakers and their accessories conform to IEC 60947,
EN 60947 international Standard
1
Approvals and certifications
SACE Emax 2 circuit-breakers and their accessories conform to the international IEC 60947, EN 60947 (harmonized in
30 CENELEC countries), CEI EN 60947 and IEC 61000 Standards and comply with the following EC directives:
– “Low Voltage Directives” (LVD) no. 2006/95/EC
– “Electromagnetic Compatibility Directive” (EMC) no. 2004/108/EC.
The ABB air circuit-breakers include a range that has been certified according to American UL 1066 Standards; it is also
certified by the Russian certification body GOST (Russia Certificate of Conformity) and has achieved China CCC Certification
(China Compulsory Certification).
Certification of conformity with the above-mentioned product Standards is carried out in compliance with the European
EN 45011 Standard by the Italian certification body ACAE (Association for the Certification of Electrical Equipment),which
is recognized by the European organization LOVAG (Low Voltage Agreement Group), and by the Swedish Intertek SEMKO
certification organization Intertek Semko which is recognized by the international organization IECEE.
Germanischer
Lloyd (GL):
Deutsch
Lloyd’s Register
of Shipping (LR):
English
Bureau Veritas (BV):
French
Nippon Kaiji Kyokai
(NKK): Japan
1SDC200415F001
1SDC200412F001
American Bureau
Shipping (ABS):
American
Russian Maritime
Register of Shipping
(RMRS): Russian
Det Norske Veritas (DNV):
Norway
1SDC200413F001
1SDC200410F001
1SDC200409F001
1SDC200411F001
1SDC200408F001
Registro Italiano
Navale (RINA):
Italian
1SDC200414F001
The main versions of the devices are about to be approved by the following shipping registers
For the types of certified circuit-breakers, certified ratings and corresponding validity, please contact ABB SACE.
ABB catalogue | 1SDC200023D0201 | 1/9
Emax2_cap01.indd 9
12/04/2013 13:53:04
Product conformity
1
Quality and Sustainability: company efficiency and integrated management
systems. Quality, Sustainability and Customer Satisfaction have always been
ABB SACE’s major commitment.
1SDC200419F001
1SDC200418F001
1SDC200417F001
1SDC200416F001
The involvement of all company departments and organization of processes have led the company to develop, implement and
certify management systems in compliance with international Standards:
– ISO 9001 for quality management
– IRIS for the quality of supplies in the railway sector (International Railway Industry Standards)
– ISO 14001 for environmental management
– OHSAS 18001 for the management of the health and safety of employees in the workplace
– SA 8000 for the management of social responsibility.
1/10 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 10
12/04/2013 13:53:05
The ABB SACE testing laboratory, accredited by ACCREDIA in compliance with
ISO/IEC 17025 Standard, provides both ABB and external customers with a
qualified service for performing certification tests on devices and electric equipment
of low and medium voltage in accordance with the relevant product Standards.
1
Thanks to the implementation of systems and their integration (Integrated Management System), ABB SACE, with a view to
continuous improvement, has implemented processes with a focus on:
– quality, preventing defects and faults along the entire supply chain
– environment, reviewing production processes in terms of ecology and waste reduction, rationalizing the consumption of raw
materials and energy, preventing pollution, containing noise emissions and reducing the quantity of rejects in the production
processes
– health and safety of employees, offering a healthy and safe workplace in all of the various stages of work with a “zero
accident objective”
– social responsibility, guaranteeing the respect of human rights and the absence of any discrimination throughout the supply
chain, and offering a favourable and transparent working atmosphere.
1SDC200421F001
1SDC200420F001
A further commitment aimed at safeguarding the environment has been achieved by assessing products’ life cycles (LCA, Life
Cycle Assessment): this includes the assessment and improvement of the environmental performance of products from the
engineering stage throughout their entire life cycle. The materials, processes and packaging used are chosen with a view to
optimising the actual environmental impact of each product, including its energy efficiency and recyclability.
ABB catalogue | 1SDC200023D0201 | 1/11
Emax2_cap01.indd 11
12/04/2013 13:53:11
ABB SACE Global Service
1
ABB’s technical assistance service offers solutions aimed at supporting the
customer in all stages of the lifespan of the circuit-breaker in service and covering
the entire chain of value; ABB is present from the moment of selection to the end of
the life of the product, thereby guaranteeing the investments of its customers.
ABB supplies annual updates regarding the evolution of the circuit-breaker ranges (Life Cycle Management) and for each
product it provides details of associated services and the level of support available, so that customers can chose the products
and spare parts best suited to their needs.
ABB’s organisation offers services that include installation and commissioning, technical training on the use and maintenance of
products, the supply of original spare parts, corrective and preventive maintenance, equipment diagnostics, modernisation of
systems with upgrades and retrofitting kits, consultancy services and personalised maintenance and service contracts.
All this is supported by one of the most extensive global sales and service networks.
1SDC200423F001
1SDC200422F001
Retrofitting kit
Through continuous research targeted at the needs of the customer, ABB SACE Service has developed innovative retrofitting
kits in order to simplify and speed up installation of a new circuit-breaker, updating the customer’s investment with the latest
technology available and with very limited down times.
The retrofitting kit between Emax2 and Emax is a retrofill solution: it is therefore possible to replace the withdrawable version of
Emax with an equivalent Emax2 model without changing the switchboard busbars, by simply removing the fixed part of Emax
replacing it with a fixed part of Emax2 which has been suitably modified with dedicated terminals.
1/12 | 1SDC200023D0201 | ABB catalogue
Emax2_cap01.indd 12
12/04/2013 13:53:12
The Ranges
SACE Emax 2 automatic circuit-breakers
2/2
SACE Emax 2 switch-disconnectors
2/4
2
SACE Emax 2 automatic circuit-breakers
for applications up to 1150V AC
2/6
SACE Emax 2 switch-disconnectors
for applications up to 1150V AC
2/8
SACE Emax 2 switch-disconnectors
for applications up to 1000 V DC
2/10
SACE Emax 2 derived versions
2/12
ABB catalogue | 1SDC200023D0201 | 2/1
Emax2_cap02.indd 1
15/04/2013 16:21:42
SACE Emax 2 automatic circuit-breakers
2
Rated service voltage Ue
[V]
690
Rated insulation voltage Ui
[V]
1000
Rated impulse withstand voltage Uimp
[kV] 12
Frequency
[Hz] 50 - 60
Number of poles
3- 4
Version
Fixed - Withdrawable
Isolation behaviour
IEC 60947-2
1SDC200424F001
Common data
SACE Emax 2
E1.2
Performance levels
Rated uninterrupted current Iu @ 40°C
B
C
N
L
[A]
630
630
250
630
[A]
800
800
630
800
[A]
1000
1000
800
1000
[A]
1250
1250
1000
1250
[A]
1600
1600
[A]
1250
1600
[A]
Neutral pole current-carrying capacity for 4-pole CBs
[%Iu]
100
100
100
100
Rated ultimate short-circuit
breaking capacity Icu
400-415 V
[kA]
42
50
66
150
440 V
[kA]
42
50
66
130
500-525 V
[kA]
42
42
50
100
690 V
[kA]
42
42
50
60
Rated service short-circuit breaking capacity Ics
[%Icu]
100
100
100
Rated short-time withstand
current Icw
(1s)
[kA]
42
42
50
15
(3s)
[kA]
24
24
36
-
Rated short-circuit making
capacity (peak value) Icm
400-415 V
[kA]
88
105
145
330
440 V
[kA]
88
105
145
286
500-525 V
[kA]
88
88
105
220
690 V
[kA]
132
1)
100
88
88
105
Utilization category (according to IEC 60947-2)
B
B
B
A
Breaking
40
40
40
40
Breaking time for I<Icw
Breaking time for I>Icw
Dimensions
25
25
25
10
H - Fixed/Withdrawable
[mm]
296/363.5
296/363.5
296/363.5
296/363.5
D - Fixed/Withdrawable
[mm]
183/271
183/271
183/271
183/271
W - Fixed 3p/4p/4p FS
[mm]
210/280
W - Withdrawable 3p/4p/4p FS
[mm]
278/348
1) Ics : 50kA for 400V…440V voltage
SACE Emax 2
E1.2
[Iu]
d 1000
1250
1600
1600 L
[No.oper.x 1000]
20
20
20
20
Frequency
[Oper./Hour]
60
60
60
60
440 V
[No.oper.x 1000]
8
8
8
3
690 V
[No.oper.x 1000]
8
6,5
6,5
1
Frequency
[Oper./Hour]
30
30
30
30
Mechanical and electrical life with regular ordinary
maintenance prescribed by the manufacturer
Electrical life
2/2 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 2
15/04/2013 16:21:43
E2.2
1SDC200427F001
1SDC200425F001
1SDC200426F001
2
E4.2
E6.2
B
N
S
H
N
S
H
V
H
V
X
1600
800
250
800
3200
3200
3200
2000
4000
4000
4000
2000
1000
800
1000
4000
4000
4000
2500
5000
5000
5000
1250
1000
1250
3200
6300
6300
6300
1600
1250
1600
4000
2000
1600
2000
2500
2000
2500
2500
100
100
100
100
100
100
100
100
50-100
50-100
50-100
42
66
85
100
66
85
100
150
100
150
200
42
66
85
100
66
85
100
150
100
150
200
42
66
66
85
66
66
85
100
100
130
130
42
66
66
85
66
66
85
100
100
100
120
100
100
100
100
100
100
100
85
100
100
100
42
66
66
85
66
66
85
100
100
100
120
42
50
50
66
36
50
66
75
100
100
100
88
145
187
220
145
187
220
330
220
330
440
88
145
187
220
145
187
220
330
220
330
440
88
145
145
187
145
145
187
220
220
286
286
88
145
145
187
145
145
187
220
220
220
264
B
B
B
B
B
B
B
B
B
B
B
40
40
40
40
40
40
40
40
40
40
40
25
25
25
25
25
25
25
25
25
25
25
371/425
371/425
371/425
371/425
371/425
371/425
371/425
371/425
371/425
371/425
371/425
270/383
270/383
270/383
270/383
270/383
270/383
270/383
270/383
270/383
270/383
270/383
276/366
384/510
762/888/1014
317/407
425/551
803/929/1069
E2.2
E4.2
E6.2
< 1600
1600
2000
2500
< 2500
2500
3200
4000
4000
5000
6300
25
25
25
20
20
20
20
15
12
12
12
60
60
60
60
60
60
60
60
60
60
60
15
12
10
8
10
8
7
5
4
3
2
15
10
8
7
10
8
7
4
4
2
2
30
30
30
30
20
20
20
20
10
10
10
ABB catalogue | 1SDC200023D0201 | 2/3
Emax2_cap02.indd 3
15/04/2013 16:21:47
SACE Emax 2 switch-disconnectors
2
Switch-disconnectors, identified with the abbreviation “/MS”, are devices that satisfy the isolating specifications provided by
the IEC 60947-3 Standard. The switch-disconnectors are derived from the corresponding automatic circuit-breakers, and they
have the same dimensions and accessory options. This version differs from the automatic circuit-breakers only because of the
absence of protection trip units.
Common data
Rated service voltage Ue
[V]
690
Rated insulation voltage Ui
[V]
1000
Rated impulse withstand voltage Uimp
[kV]
12
Frequency
[Hz]
50 - 60
3- 4
Version
Fixed - Withdrawable
Isolation behaviour
IEC 60947-3
1SDC200428F001
Number of poles
SACE Emax 2
E1.2
Performance levels
B/MS
Rated uninterrupted current Iu @ 40°C
N/MS
[A]
630
250
[A]
800
630
[A]
1000
800
[A]
1250
1000
[A]
1600
1250
[A]
1600
Neutral pole current-carrying capacity for 4-pole CBs
[%Iu]
100
100
Rated short-time withstand
current Icw
(1s)
[kA]
42
50
(3s)
[kA]
24
36
Rated short-circuit making
capacity (peak value) Icm
400-415 V
[kA]
88
105
440 V
[kA]
88
105
500-525 V
[kA]
88
105
690 V
[kA]
88
105
AC-23A
AC-23A
Utilization category (according to IEC 60947-3)
Dimensions
H - Fixed / Withdrawable
[mm]
296 / 363.5
296 / 363.5
D - Fixed / Withdrawable
[mm]
183 / 271
183 / 271
W - Fixed 3p/4p/4p FS
[mm]
210 / 280
W - Withdrawable 3p/4p/4p FS
278 / 348
SACE Emax 2
E1.2
Mechanical and electrical life with regular ordinary
maintenance prescribed by the manufacturer
[Iu]
< 1000
1000
1600
[No.oper.x 1000]
20
20
20
[Oper./Hour]
60
60
60
440 V
[No.oper.x 1000]
8
8
8
690 V
[No.oper.x 1000]
8
6.5
6.5
Frequency
[Oper./Hour]
30
30
30
Frequency
Electrical life
2/4 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 4
15/04/2013 16:21:47
E2.2
E4.2
E6.2
B/MS
N/MS
H/MS
N/MS
H/MS
V/MS
H/MS
1600
800
800
3200
3200
2000
4000
4000
2000
1000
1000
4000
4000
2500
5000
5000
1250
1250
3200
6300
6300
1600
1600
4000
2000
2000
X/MS
2500
2500
100
100
100
100
100
100
50-100
50-100
42
66
85
66
85
100
100
120
42
50
66
36
66
75
100
100
88
145
187
145
187
220
220
264
88
145
187
145
187
220
220
264
88
145
187
145
187
220
220
264
88
145
187
145
187
220
220
264
AC-23A
AC-23A
AC-23A
AC-23A
AC-23A
AC-23A
AC-23A
AC-23A
371 / 425
371 / 425
371 / 425
371 / 425
371 / 425
371 / 425
371 / 425
371 / 425
270 / 383
270 / 383
270 / 383
270 / 383
270 / 383
270 / 383
270 / 383
270 / 383
276 / 366
384 / 510
762 / 888 / 1014
317 / 407
425 / 551
803 / 929 / 1069
E2.2
2
1SDC200431F001
1SDC200429F001
1SDC200430F001
The device, when in the open position, guarantees an isolating distance between the main contacts of the circuit-breaker that
is sufficient to ensure that the installation downstream is not live.
Furthermore the switch-disconnectors, if used with an external protection relay with maximum delay of 500ms, enable a
breaking capacity at a maximum rated operating voltage (Ue) equal to the value of rated short-time withstand current (Icw) for
one second.
E4.2
E6.2
< 1600
1600
2000
2500
< 2500
2500
3200
4000
4000
5000
6300
25
25
25
20
20
20
20
15
12
12
12
60
60
60
60
60
60
60
60
60
60
60
15
12
10
8
10
8
7
5
4
3
2
15
10
8
7
10
8
7
4
4
2
2
30
30
30
30
20
20
20
20
10
10
10
ABB catalogue | 1SDC200023D0201 | 2/5
Emax2_cap02.indd 5
15/04/2013 16:21:49
SACE Emax 2 automatic circuit-breakers
for applications up to 1150V AC
ABB SACE offers a solution designed for electrical applications with voltages up to 1150V in alternating current. The 1150V AC
range, which maintains the same dimensions and accessories as the standard 690V AC range, is identified by the letters “/E”.
2
Rated service voltage Ue
[V]
1150
Rated insulation voltage Ui
[V]
1250
Rated impulse withstand voltage Uimp
[kV]
12
Frequency
[Hz]
50 - 60
Number of poles
3- 4
Version
Fixed - Withdrawable
Isolation behaviour
IEC 60947-2
1SDC200424F001
Common data
SACE Emax 2
E1.2
Performance levels
N/E
Rated uninterrupted current Iu @ 40°C
[A]
630
[A]
800
[A]
1000
[A]
1250
[A]
1600
[A]
Neutral pole current-carrying capacity for 4-pole CBs
[%Iu]
100
Rated ultimate short-circuit breaking
capacity Icu
1000 V
[kA]
30
1150 V
[kA]
25
Rated service short-circuit breaking capacity Ics
[%Icu]
100
Rated short-time withstand current Icw (1s)
[kA]
25
(3s)
[kA]
25
1000 V
[kA]
63
1150 Z
[kA]
Rated short-circuit making
capacity (peak value) Icm
Utilization category (according to IEC 60947-3)
SACE Emax 2
E1.2
Mechanical and electrical life with regular ordinary
maintenance prescribed by the manufacturer
Electrical life
53
B
[Iu]
< 1000
1000
[No.oper.x 1000]
20
20
1600
20
Frequency
[Oper./Hour]
60
60
60
1150 V
[No.oper.x 1000]
1
1
1
Frequency
[Oper./Hour]
30
30
30
2/6 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 6
15/04/2013 16:21:49
1SDC200427F001
1SDC200425F001
1SDC200426F001
2
E2.2
E4.2
E6.2
H/E
H/E
X/E
800
3200
4000
1000
4000
5000
1250
6300
1600
2000
2500
100
100
50 - 100
30
50
65
30
30
65
100
100
100
30
50
65
30
30
65
63
105
143
53
105
143
B
B
B
E2.2
E4.2
E6.2
< 2000
2000
2500
< 3200
3200
4000
4000
5000
6300
25
25
20
20
20
15
12
12
12
60
60
60
60
60
60
60
60
60
2
2
2
1
1
1
1
1
1
30
30
30
20
20
20
10
10
10
ABB catalogue | 1SDC200023D0201 | 2/7
Emax2_cap02.indd 7
15/04/2013 16:21:52
SACE Emax 2 switch-disconnectors
for applications up to 1150V AC
2
The switch-disconnectors for applications at 1150V, identified by the letters “/E” and “/MS”, are derived from the corresponding
standard automatic circuit-breakers, of which maintain the overall dimensions and the possibility of mounting accessories.
The switch-disconnectors are not equipped with Ekip protection trip units. By means of external protection relay with 500 ms
maximum timing, the Icu breaking capacity is equal to the value of Icw (1s).
Rated service voltage Ue
[V]
1150
Rated insulation voltage Ui
[V]
1250
Rated impulse withstand voltage Uimp
[kV]
12
Frequency
[Hz]
50 - 60
Number of poles
3- 4
Version
Fixed - Withdrawable
Isolation behaviour
IEC 60947-3
1SDC200428F001
Common data
SACE Emax 2
E1.2
Performance levels
N/E MS
Rated uninterrupted current Iu @ 40°C
[A]
630
[A]
800
[A]
1000
[A]
1250
[A]
1600
[A]
Neutral pole current-carrying capacity for 4-pole CBs
Rated short-time withstand current Icw
Rated short-circuit making capacity (peak value) Icm
[%Iu]
100
(1s)
[kA]
25
(3s)
[kA]
25
1000 V
[kA]
53
1150 V
[kA]
53
SACE Emax 2
E1.2
Mechanical and electrical life with regular ordinary
maintenance prescribed by the manufacturer
Electrical life
[Iu]
< 1000
1000
1600
[No.oper.x 1000]
20
20
20
Frequency
[Oper./Hour]
60
60
60
1150 V
[No.oper.x 1000]
1
1
1
Frequency
[Oper./Hour]
30
30
30
2/8 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 8
15/04/2013 16:21:53
1SDC200431F001
1SDC200429F001
1SDC200430F001
2
E2.2
E4.2
E6.2
H/E MS
H/E MS
X/E MS
800
3200
4000
1000
4000
5000
1250
6300
1600
2000
2500
100
100
50 - 100
30
50
65
30
30
65
53
105
143
53
105
143
E2.2
E4.2
E6.2
< 2000
2000
2500
< 3200
3200
4000
4000
5000
6300
25
25
20
20
20
15
12
12
12
60
60
60
60
60
60
60
60
60
2
2
2
1
1
1
1
1
1
30
30
30
20
20
20
10
10
10
ABB catalogue | 1SDC200023D0201 | 2/9
Emax2_cap02.indd 9
15/04/2013 16:21:54
SACE Emax 2 Switch-disconnectors
for applications up to 1000V DC
2
ABB SACE extends its solutions to applications in direct current with a range of switch-disconnectors for applications up to
1000V, which comply with the international IEC60947-3 standard.
For all applications in which integrated protection is requested in addition to isolation, ABB SACE offers SACE Emax automatic
circuit-breakers with PR122/DC and PR123/DC. For further information, please refer to the technical catalogue “SACE Emax DC.
Low voltage air circuit-breakers for direct current applications”.
Rated service voltage Ue
[V]
750 (3p) / 1000 (4p)
Rated insulation voltage Ui
[V]
1000
Rated impulse withstand voltage Uimp
[kV]
12
Number of poles
3- 4
Version
Fixed - Withdrawable
Isolation behaviour
IEC 60947-3
1SDC200428F001
Common data
SACE Emax 2
E1.2
Performance levels
N/DC MS
Rated uninterrupted current Iu @ 40°C
[A]
800
[A]
1250
[A]
[A]
[A]
[A]
Poles
3
4
4
Rated service voltage Ue
750
750
1000
Rated insulation voltage Ui
1000
1000
1000
20
Rated short-time withstand current Icw
(1s)
[kA]
20
25
Rated short-circuit making capacity (peak value) Icm
750 V
[kA]
40
53
1000 V
[kA]
40
40
Utilization category (according to IEC 60947-3)
SACE Emax 2
E1.2
Mechanical and electrical life with regular ordinary
maintenance prescribed by the manufacturer
Electrical life
[Iu]
< 1000
1250
[No.oper.x 1000]
20
20
Frequency
[Oper./Hour]
60
60
1000 V
[No.oper.x 1000]
1
1
Frequency
[Oper./Hour]
Note: by means of external protection relay with 500 ms maximum timing, the breaking capacity Icu at the maximum rated use voltage is equal to the value of Icw (1s).
2/10 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 10
15/04/2013 16:21:55
1SDC200431F001
1SDC200429F001
1SDC200430F001
2
E2.2
E4.2
E6.2
S/DC MS
H/DC MS
X/DC MS
1250
1250
4000
1600
1600
5000
2000
2000
6300
2500
2500
3200
4000
3
4
4
3
4
4
3
4
4
750
750
1000
750
750
1000
750
750
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
25
40
25
40
50
40
65
65
65
53
84
53
84
105
84
143
143
53
E2.2
84
E4.2
143
143
E6.2
< 2000
2000
2500
< 3200
3200
4000
4000
5000
6300
25
25
20
20
20
15
12
12
12
60
60
60
60
60
60
60
60
60
2
2
2
1
1
1
1
1
1
ABB catalogue | 1SDC200023D0201 | 2/11
Emax2_cap02.indd 11
15/04/2013 16:21:56
SACE Emax 2 derived versions
1SDC200435F001
1SDC200439F001
1SDC200441F001
1SDC200437F001
1SDC200438F001
1SDC200440F001
1SDC200434F001
1SDC200433F001
– Sectionalizing truck CS: in normal operating conditions
of the electrical circuit, this device is inserted in the fixed
part and short-circuits the upper and lower terminals of
the power circuit. When maintenance activities need to be
carried out, the sectionalizing truck is removed and the
part of the system involved is isolated. The device can be
accessorised with a keylock and padlocks for locking in the
withdrawn position.
1SDC200436F001
1SDC200432F001
2
Safety is an indispensable requirement that must always be guaranteed in electrical installations. In this
regard, ABB SACE offers devices developed to further increase safety standards during inspection and
maintenance activities on electrical installations.
In particular, in a withdrawable version, ABB SACE Emax 2 offers:
– Earthing truck MT: this device enables all phases of
the electrical circuit in which maintenance needs to be
performed to be earthed 1).
The earthing truck is available in two versions: for earth
connection from the upper or lower terminals.
– Earthing switch with making capacity MTP: similar to the
MT device, this differs due to the presence of a mechanical
stored energy control which allows the circuit to be opened
and closed. Two versions of this earthing switch are also
available: for earth connection from the upper or lower
terminals. It can also be accessorised with a keylock or
padlocks for locking in the open position.
1) The earthing circuit is dimensioned for a short-time current equal to 60% of
the maximum Icw of the circuit-breaker from which it is derived (IEC 60439-1)
2/12 | 1SDC200023D0201 | ABB catalogue
Emax2_cap02.indd 12
15/04/2013 16:21:57
Common data
Rated service voltage Ue
[V]
690
Rated insulation voltage Ui
[V]
1000
Rated impulse withstand voltage Uimp
[kV]
12
Frequency
[Hz]
50 - 60
2
Number of poles
3-4
Version
Withdrawable
SACE Emax 2
E2.2
Performance levels
CS
MT
MTP
CS
E4.2
MT
MTP
CS
E6.2
MT
MTP
Rated uninterrupted current Iu @ 40°C
2500
2500
2500
4000
4000
4000
6300
6300
6300
Neutral pole current-carrying capacity for 4-pole CBs
100
100
100
100
100
100
50-100
50-100
50-100
Rated short-time withstand current Icw (1s) [kA]
-
30
30
-
50
50
-
50
50
Other versions
Corrosive substances, vibrations, shocks or very low temperatures can be present in particular applications. In this regard,
SACE Emax 2 circuit-breakers offer specific solutions developed precisely for:
– Aggressive environments, such as industrial processes for paper production, oil refining or water treatment, which are
subject to high levels of sulphur dioxide (SO2) and hydrogen sulphide (H2S) contamination.
– Antiseismic installations, for areas with seismic risk where industrial and civil activities take place and where the continuity
of critical processes must be guaranteed even in the case of particular natural events.
For further detail, please contact ABB SACE.
ABB catalogue | 1SDC200023D0201 | 2/13
Emax2_cap02.indd 13
15/04/2013 16:21:57
Emax2_cap02.indd 14
15/04/2013 16:21:57
Protection trip units
Introduction
3/2
Architecture
3/4
Protection trip units for power distribution
Ekip Dip
3/6
Ekip Touch
3/10
Ekip Hi-Touch
3/20
3
Protection trip units for generators
Ekip G Touch
3/24
Ekip G Hi-Touch
3/29
Protection trip units for power control
Ekip Power Controller
3/32
Technical characteristics for protection trip units
Protection functions
3/38
Measurement functions
3/46
ABB catalogue | 1SDC200023D0201 | 3/1
Emax2_cap03.indd 1
15/04/2013 16:45:54
Protection trip units
Introduction
The SACE Emax 2 Ekip protection trip units are the new benchmark for the
protection, measurement and control of low voltage electrical systems. The result
of ABB SACE’s experience and research, they make Emax 2 not only a circuitbreaker, but an actual Power Manager with all the functions necessary for optimal
management of the system without the need for external devices.
3
The protection units are divided into two families: Ekip for distribution protection and Ekip G for generator protection. The range of
trip units is available with three levels of performance, Dip, Touch and Hi-Touch, to satisfy simple to advanced applications. Exclusive
functions such as the Ekip Power Controller and Network Analyzer complete the range, enabling power management and analysis of
energy quality.
The complete, flexible Ekip protection trip unit offering, which can be adapted to the actual level of protection required, is shown
below:
Fields of
applications
Distribution
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
Measurement and
Protection of Voltage,
Power, Energy
Network
Analyzer
Power
Control
–
–
–
–
•
with Ekip Measuring
with Ekip Measuring Pro
–
•
•
•
•
•
•
•
–
•
•
•
•
with Ekip Multimeter
Ekip Dip
Ekip Touch
Measurement of
Voltage, Power, Energy
Measurement and
Protection of Current
Generators
with Ekip Power Controller
with Ekip Power Controller
Ekip Power Controller function
monitors installation loads
and generators, permitting
the power consumed to be
limited and allowing savings
on electricity bills.
3/2 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 2
15/04/2013 16:45:55
The protection units for power distribution, available in the LI, LSI and LSIG versions, are suited to all distribution systems.
The Ekip trip units are designed to protect a vast range of applications, such as use with transformers, motors and drives. Ekip
Dip, Ekip Touch or Ekip Hi-Touch can be selected, depending on the complexity of the system, the need to take voltage or
energy measurements or to include control systems in switchgear.
Ekip G enables the protection of generators without the use of external devices that require dedicated relays and wiring.
Ekip G increases efficiency from the design stage to installation, minimizing the time needed for realization and commissioning
of the system, and ensuring high levels of accuracy and reliability of all protection devices required for running generators in
applications such as naval, GenSet or cogeneration.
3
Ekip Power Controller is the new function that controls the power absorbed, thereby increasing the efficiency of the system.
This ABB SACE patented function measures power and energy but also controls, without the use of complex external
automation logic, loads and generators in order to optimize the power consumed.
Thanks to the Network Analyzer function integrated in all Hi-Touch versions, the quality of energy in terms of harmonics,
micro-interruptions or voltage dips is monitored without the need for dedicated instrumentation. This allows effective preventive
and corrective action to be implemented through accurate analysis of the faults, thereby improving the efficiency of the system.
1SDC200442F001
Ekip G enables the protection
of generators without the
use of external devices that
require dedicated relays and
wiring.
ABB catalogue | 1SDC200023D0201 | 3/3
Emax2_cap03.indd 3
15/04/2013 16:45:55
Protection trip units
Architecture
All SACE Emax 2 circuit-breakers are equipped with protection trip units that are
interchangeable from the front with just a few, simple operations by the customer.
There is no need to dismantle the circuit-breaker or access dangerous parts.
1SDC200444F001
3
This enables personalization of the functions available, even during commissioning or when the circuit-breaker has already been
installed. In particular, SACE Ekip consists of:
– Protection trip unit, available with different interfaces and versions that range from basic to more complete; it contains a
latest generation microprocessor that performs all the functions of protection and control.
– Ekip Measuring Module, connected internally to Emax 2, performs voltage, power and energy measurements with high
accuracy without requiring any external connection or voltage transformer. The Ekip Measuring Pro version also performs
all protection functions based on voltage and power without the need for external units, thereby simplifying design and
construction of the system.
– Interchangeable rating plug enables all protection thresholds to be adjusted according to the rated current, increasing
flexibility for the customer. It is useful in installations that are prepared for future development or in cases in which the power
supplied may be limited temporarily.
– Main board is the mechanical housing of the trip unit, which includes a micro-controller for measuring currents and the
self-protection functions. The separation of trip units ensures excellent reliability and immunity to conducted and radiated
emissions. Integrated new generation Rogowski sensors, which are sensitive to the true r.m.s. value of the current, guarantee
high accuracy of both measurements and protection.
3/4 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 4
15/04/2013 16:45:56
All protection trip units of the SACE Emax 2 family are self-powered by current that
crosses the circuit-breaker. They guarantee excellent reliability thanks to a system
of self-control of internal connections. The setting, testing and downloading of
reports can be carried out directly from a Smartphone, Tablet or PC.
In addition, the commissioning stage can be further accelerated, minimizing the possibility of errors, by directly configuring the
protection trip unit with the DOC design software settings.
3
1SDC200445F001
Cartridge-type modules that are easily installed on-board enable the units to be integrated into the most complex systems.
Additional functions can be created, such as:
– Synchrocheck, to check the synchronization of the two half-busbars before enabling circuit-breaker closing;
– Communication with all supervision systems available in the Modbus, Profibus and DeviceNet protocols as well as the
modern Modbus TCP, Profinet and EtherNet/IP protocols;
– Integration into Smart Grids thanks to the possibility of communicating without the assistance of any external converter,
according to standards (IEC 61850) already in use in the automation systems of high and medium voltage substations;
– Multi-voltage supply module, which enables the protection trip unit and modules present to be supplied with any auxiliary
voltage available in direct or alternating current;
– Programmable logic management thanks to Ekip Signalling modules that make a high number of electrical input and output
contacts;
– Logical interlocks between circuit-breakers, which can be made with the Ekip Link proprietary communication protocol,
avoiding complex wiring thanks to the transmission of all signals via bus;
– Increase of current-carrying capacity in switchgear of the circuit-breaker by means of Ekip Fan which continuously monitors
the internal temperature at the fixed part and activates cooling fans if the temperature is too high.
ABB catalogue | 1SDC200023D0201 | 3/5
Emax2_cap03.indd 5
15/04/2013 16:45:59
Protection trip units for power distribution
Ekip Dip
3
Characteristics
Ekip Dip is the new protection trip unit of the SACE Emax 2 family for all
applications in which high accuracy and reliable protection against overcurrent are
required. Ekip Dip offers a complete set of standard protection functions. Dedicated
LEDs allow the fault that caused tripping to be determined.
The unit is
– Ekip Dip
– Ekip Dip
– Ekip Dip
available in the following versions:
LI
LSI
LSIG
1
2
4
3
5
1SDC200446F001
6
Key:
1. Power-on LED for signalling correct operation
(watchdog)
2. LEDs for alarm signalling of L, S, I and G
protection functions and diagnostics
4. Dip switches for setting the network frequency
and neutral protection device
5. Pushbutton for test and for indicating the cause
of tripping
6. Test and programming connector
3. Dip switches for setting the protection functions
3/6 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 6
15/04/2013 16:45:59
Protection functions
Ekip Dip offers overcurrent protection functions and, in the event of tripping, controls the opening of the circuit-breaker,
preventing it from closing again unless it has been reset by the operator (lockout device – code ANSI 86).
Overload (L - ANSI 49): with inverse long-time delay trip of the type t = k/l2 available with 25 current
thresholds and 8 curves, it provides effective protection of all systems. A pre-alarm warning is also
available on reaching 90% of the threshold set.
t
I1
t1
3
I
Time-delayed overcurrent (S - ANSI 51 & 50TD): with constant tripping time (t = k), or with constant
specific let-through energy (t = k/l2), it provides 15 current thresholds and 8 curves, for fine adjustment.
The function can be excluded by setting the dip switch combination to “OFF”.
t
I2
t2
I
Thermal memory: for L and S protection functions, this is used to protect components, such as
transformers, from overheating following an overload. The function, which can be enabled by the Ekip
Connect software, adjusts the protection tripping time according to the length of time that has elapsed
since the first overload, taking into account the amount of heat generated.
t
L
cold curve
S
hot curve
I
Instantaneous overcurrent (l - ANSI 50): with tripping curve without intentional delay, it offers 15
tripping thresholds and can be excluded by setting the dip switch combination to “OFF”.
t
I3
I
Earth fault (G - ANSI 51N & 50NTD): with tripping time independent of current (t = k) or constant
specific let-through energy (t = k/l2). The function can be excluded by setting the dip switch combination
to “OFF”.
t
I4
t4
I
t
100% 200%
50% 150%
Neutral protection: available at 50%, 100% or 200% of the phase currents, or disabled,
it is applied to the overcurrent protections L, S and I.
L
S
I
I
ABB catalogue | 1SDC200023D0201 | 3/7
Emax2_cap03.indd 7
15/04/2013 16:45:59
Protection trip units for power distribution
Ekip Dip
3
Measurements
The Ekip Dip unit measures phase and neutral current with great accuracy: 1% including the current transformers in the 0.2 ...
1.2 In range (class 1 in accordance with IEC 61557-12). Using the current sensors in the circuit-breaker and without the need to
install an external measuring system, it is possible to view the measurements by the display on the front of the Ekip Multimeter
and Ekip Control Panel.
Ekip Dip also records the characteristics of the circuit-breaker, to enable a rapid analysis in the event of maintenance:
– Maximum and average current values per phase;
– Date, time, fault current per phase and type of protection tripped over the last 30 trips;
– Date, time and type of operation of the last 200 events (for example: opening/closing of circuit-breaker, pre-alarms, editing
settings);
– Number of mechanical and electric operations of the circuit-breaker;
– Total operating time;
– Contact wear;
– Date and time of the last maintenance carried out, in addition to the estimate of the next maintenance required;
– Circuit-breaker identifying data: type, serial number, firmware version, name of the device as assigned by the user.
The values can be displayed on the front of the Ekip Multimeter or Ekip Control Panel or by Ekip Connect software on a
Smartphone, Tablet or PC by using the communication units Ekip T&P or Ekip Bluetooth.
Watchdog
All the protection trip units of the SACE Emax 2 family ensure high reliability owing to an electronic circuit that periodically controls
the continuity of the internal connections (trip coil, rating plug and current sensors). In the event of a malfunction, the LEDs indicate
the corresponding alarm to enable the fault to be identified rapidly. Furthermore, Ekip Dip detects and indicates that the circuitbreaker has been opened because one of the protection functions has been tripped (Ansi BF code).
In order to preserve the correct operation of the unit, Ekip Dip is also provided with self-protection against abnormal temperature
(OT) inside the protection trip unit. The user can set it to open the circuit-breaker or to merely indicate an alarm.
User interface
Ekip offers a great variety of thresholds and trip times, the protections can be set by dip-switches. Up to 5 LEDs are also
available (depending on the version) to indicate correct operation or alarms. The interface always enables the status of the
installation to be identified clearly and quickly:
– correct operation (green LED)
– overcurrent pre-alarms or alarms
– presence of self-control functions alarms
– maintenance interval expired
– indication of tripped protection after a fault
The protection tripped indication is activated by pressing the iTest key, and operates without the need of an external power
supply because a battery is installed inside the unit.
Communication
The Ekip Bluetooth wireless communication unit enables the operator to interact with the protection trip unit by computer,
Smartphone or Tablet. In fact, the free Ekip Connect software for Smartphones, Tablets and PC, enables measurements and
fault data to be read and alarm status and information on the circuit-breaker or maintenance to be displayed. It is also possible
to set parameters such as date, time and thermal memory and for the records to be reset.
3/8 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 8
15/04/2013 16:45:59
Test function
The test port on the front of the protection trip unit can be used to run the circuit-breaker tests by connecting one of the
following devices:
– Ekip TT to run the trip test, the LEDs test and check absence of alarms detected by the watchdog function;
– Ekip T&P to permit not only the trip test and LEDs test but also to run the test of the individual protection functions and save
the relative report;
– ITest key that is pressed to run the battery test when the circuit-breaker is disconnected.
3
Supply
The Ekip Dip protection trip unit does not require an external supply for the protection functions or for the alarm indication
functions because it is self-supplied by the current sensors installed on the circuit-breaker. A three-phase 100A current suffices
to activate the LED indications.
The Ekip Supply module enables an auxiliary supply to be easily connected and is able to receive both a direct current supply
(24-48VDC or 110-240VDC) and an alternating current (110-240VAC) to activate additional functions such as:
– G protection at values below 100A or below 0.2 In;
– connecting to external devices such as Ekip Multimeter and Ekip Control Panel;
– recording the number of operations.
The Ekip Dip protection trip unit also has a battery that enables the indication of the cause of the fault to be viewed for an unlimited
time after tripping. In addition to that, the battery enables date and time to be maintained and updated, thus ensuring the chronology
of the events. On the other hand, when the unit is switched off, the battery test can be run by simply pressing the iTest key.
Supply
Ekip Supply
Nominal voltage
24-48V DC
110-240V AC/DC
Voltage range
21.5 - 53V DC
105-265V AC/DC
Rated power (including modules)
10W max.
10W max.
Inrush current
~10 A for 5 ms
~10 A for 5 ms
Whenever cartridge modules are not used in the terminal box area, the trip unit can be supplied by means of a galvanically
isolated 24V DC auxiliary voltage.
ABB catalogue | 1SDC200023D0201 | 3/9
Emax2_cap03.indd 9
15/04/2013 16:45:59
Protection trip units for power distribution
Ekip Touch
Characteristics
Ekip Touch is the new protection trip unit for SACE Emax 2 that provides a
complete series of protections and high accuracy measurements of all electric
parameters and can be integrated perfectly with the most common automation and
supervision systems.
3 The simple and intuitive interface enables the operator to access all the information
and settings rapidly and easily by minimizing installation and commissioning time.
The unit is available in the versions:
– Ekip Touch LI
– Ekip Touch LSI
– Ekip Touch LSIG
2
3
4
5
1
6
1SDC200466F001
7
Key:
4. Alarm LED
1. Wide high-resolution colour touchscreen display
5. Home pushbutton to return to home page
2. Power-on LED to indicate correct operation
(watchdog)
6. Pushbutton for test and indicating cause of trip
7. Test and programming connector
3. Pre-alarm LED
3/10 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 10
15/04/2013 16:46:00
Protection functions
Ekip Touch enables all the protection functions to be set with a few simple steps directly from the wide touchscreen display. If
the circuit breaker is tripped it must be reset manually or electrically by the operator (lockout relay – code ANSI 86).
t
Extremely Inverse
Very Inverse
Standard Inverse
Overload (L - ANSI 49): available with three different types of trip curve:
1. t = k/l2 with inverse long time;
2. IDMT in accordance with IEC 60255-3 for coordination with medium voltage protections, that are
available according to the Standard Inverse (SI), Very Inverse (VI) and Extremely Inverse (EI) curves;
3. with t = k/l4 curve for better coordination with upstream circuit-breakers or with fuses.
3
I
The thresholds can be fine tuned (for example 1A for circuit-breaker E1.2 1000A) and the timings to the
second can be set directly from the display. The settable pre-alarm indicates the set threshold is reached
before the protection is tripped. The protection can be disabled by rating plug L=off.
Time-delayed overcurrent (S - ANSI 51 & 50TD): with constant trip time (t = k), or constant specific letthrough energy (t = k/l2).
t
I2
t2
I
Thermal memory: for protections L and S it is used to protect the components, such as transformers,
against overheating following overloads. The protection adjusts the trip time of the protection according
to how much time has elapsed after the first overload, taking account of the overheating caused.
t
L
cold curve
S
hot curve
I
Instantaneous overcurrent (l - ANSI 50): with trip curve without intentional delay.
t
Closing on short-circuit (MCR): the protection uses the same algorithm of the protection l, limiting
operation to a settable time window from the closing of the circuit-breaker. The protection can be
disabled, also alternatively to protection l. The function is active with an auxiliary supply.
I3
I
Earth fault (G - ANSI 51N & 50NTD): with trip time independent of the current (t = k) or with constant
specific let-through energy (t = k/l2). A pre-alarm indication is also available when 90% of the threshold is
reached to activate corrective measures before the protection is tripped. The function also enables the
trip to be excluded so that only the alarm is indicated, for use in installations where continuity of service is
an essential requirement.
t
I4
t4
I
ABB catalogue | 1SDC200023D0201 | 3/11
Emax2_cap03.indd 11
15/04/2013 16:46:00
Protection trip units for power distribution
Ekip Touch
Earth fault on toroid (G ext - ANSI 51G & 50GTD): with trip time independent of the current (t = k) or
with constant specific let-through energy (t = k/l2). Pre-alarm that 90% threshold has been reached permit
the fault to be reported to supervision systems without interruption of continuity. The protection uses the
external toroid installed, for example, on the star centre of the transformer, and is an alternative to the G
and Rc functions. The function is active with an auxiliary supply.
t
I4
t4
I
3
t
Neutral protection: available at 50%, 100%, 150% or 200% of the phase currents, or disabled, it is
applied to the overcurrent protections L, S and I.
100% 200%
50% 150%
L
S
I
I
t
steady
state
start-up
I
Start-up function: enables protections S, I and G to operate with higher trip thresholds during the
starting phase, avoiding untimely trips due to high inrush currents of certain loads (motors, transformers,
lamps). The starting phase lasts 100 ms to 30 s and is recognized automatically by the trip unit:
– at the closing of the circuit-breaker with a self-supplied trip unit;
– when the peak value of the maximum current exceeds the set threshold (0.1…10 x In) with an externally
supplied trip unit; a new start-up is possible after the current falls below the threshold.
Current unbalance (IU – ANSI 46): with constant trip time (t = k), protects from an unbalance between
the currents of the single phases protected by the circuit breaker.
t
I7
t7
Zone 3
Zone 2
Zone 1
I
Zone selectivity for S and G protection (ANSI 68): can be used to minimize circuit-breaker trip times
closer to the fault. The protection is provided by connecting all the zone selectivity outputs of the trip
units belonging to the same zone and taking this signal to the trip unit input that is immediately upstream.
Each circuit-breaker that detects a fault reports it to the circuit-breaker upstream; the circuit-breaker thus
detects the fault but does not receive any communication from those downstream and opens without
waiting for the set delay to elapse. It is possible to enable zone selectivity if the fixed-time curve has been
selected and the auxiliary supply is present.
Current thresholds: this function enables the realization of four independent thresholds to be indicated in
order to enable corrective action implementation before the overload L protection trips the circuit-breaker.
For example, by disconnecting loads located downstream of the circuit-breaker that are controlled by Ekip
Signalling.
Power Controller: Power controller function (optional) with Ekip Measuring module.
3/12 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 12
15/04/2013 16:46:00
1SDC200467F001
Protection functions with Ekip Measuring Pro
The Ekip Touch protection functions can be further increased by using the Ekip Measuring Pro measuring
and protection module. With this module, all the protection functions linked to voltage, frequency and
power can be enabled, thus making Ekip Touch a multifunction unit that can measure, control and protect
even the most complex installation.
A different operating mode can be chosen for each protection function:
1. Active: protection enabled by opening of the circuit-breaker when the threshold is reached;
2. Only alarm: protection active, with only alarm indication when the threshold is reached;
3. Deactivated: protection disabled.
Furthermore, when the voltage and frequency protections are activated, they indicate an alarm status
even when the circuit-breaker is open so that a fault can be identified before the circuit-breaker closes.
3
Undervoltage (UV - ANSI 27): with constant trip time (t = k), function is tripped when phase voltage falls
below set threshold.
t
U8
t8
V
Overvoltage (OV - ANSI 59): with constant trip time (t = k), function is tripped when phase voltage
exceeds the set threshold.
t
U9
t9
t8
V
Underfrequency (UF - ANSI 81L): with constant trip time (t = k), function is tripped when network
frequency falls below set threshold.
t
f12
t12
f
Overfrequency (OF - ANSI 81H): ): with constant trip time (t = k), function is tripped when network
frequency exceeds the set threshold.
t
f13
t13
f
ABB catalogue | 1SDC200023D0201 | 3/13
Emax2_cap03.indd 13
15/04/2013 16:46:00
Protection trip units for power distribution
Ekip Touch
mean
Voltage unbalance (VU – ANSI 47): with constant trip time (t = k), protects against an unbalance
between the voltages of the individual phases that are protected by the circuit-breaker.
U14
U1
U2
U3
3
PE
L1 L2 L3 N
Residual current (Rc – ANSI 64 & 50NDT): with constant temperature (t=k) protects against indirect
contacts and is integrated into Ekip Touch by a dedicated residual current rating plug and external toroid.
The protection is an alternative to the functions G and Gext.
LOAD
Reverse active power (RP - ANSI 32R): with constant trip time (t = k), function is tripped when total
active power – in the opposite direction of the current - exceeds the set threshold.
M
RP
In addition to the protection functions, the following indication and control functions are available to
warn the user that a given condition has been reached. The active indications are always shown on the
display and are also available by communication on the system bus (with Ekip Com modules) or electrical
indication (with Ekip Signalling modules).
Synchrocheck (SC - ANSI 25): the synchronism control function compares the voltages in the module,
the frequency and phase of the two circuits to which the circuit-breaker is connected. Ekip Touch
indicates that conditions have been reached that enable the two lines to be made parallel. The function is
available with two work modes:
– In systems with both busbars supplied, where synchronism is determined by:
1. voltage of the two half-busbars above the Ulive threshold for the set time
2. difference of the module of the two voltages below the threshold 'U
3. difference of the frequency of the two voltages below the threshold 'f
4. difference of the phase of the two voltages below the threshold '
5. desirable time for synchronism condition tsyn
6. circuit-breaker open
– In systems with an out-of-service line (dead busbar), where the synchronism condition is determined by
the concurrence of the following conditions for the tref set time:
1. voltage of the active half-busbar above threshold Ulive
2. voltage of the dead half-busbar below threshold Udead
3. circuit-breaker open
U, f,
In both cases, synchronism consent is withdrawn when one of the above conditions is missing and it has not
been less than 200ms from the change of the circuit-breaker condition (when the relationship has been set).
The indication of reached synchronism is available directly as an electrical indication via a contact that is always
supplied with the module. The function can be activated simply by connecting the Ekip Synchrocheck module to
any Ekip Touch provided with an Ekip Measuring Pro module.
V1
Cyclical direction of the phases (ANSI 47): indicates an alarm through inversion of the phases sequence.
V3
V2
Power factor (ANSI 78): available with a three-phase threshold, warns when the system operates with a
power factor that is less than the set power factor.
3/14 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 14
15/04/2013 16:46:01
1SDC200470F001
1SDC200469F001
1SDC200468F001
Measurements
Measurements and meters
All versions of the Ekip Touch unit measure the RMS value of the currents of
the three phases (L1, L2, L3) and of neutral (Ne) with 1% accuracy in the 0.2 to
1.2 In range (class 1 in accordance with IEC 61557-12). The complete range of
measurement is from 0.03 to 16x In, where In is the value of the rating plug.
The display shows the current of the most loaded phase both in numeric and
analogue format on an ammeter with a 0-125% In scale for rapid identification of
the load of the circuit-breaker.
3
Alternatively, bar graphs that show the currents of the three phases and of neutral
on a 0-125% In scale in addition to the numeric value of the most loaded phase
can be selected as the default page. The bar graphs are yellow in the event of a
pre-alarm and red in the event of an overload to enable an irregular condition to be
identified immediately.
Where applicable, the measurement of the earth fault current is shown on a
dedicated page. The ammeter can operate both in self-supplied mode and with
auxiliary voltage. In the latter case, the display always has back lighting and the
ammeter is also active at currents below 100A.
Adding the Ekip Measuring or Ekip Measuring Pro module to Ekip Touch enables
Ekip Touch to be used as a multimeter to measure the values of:
– Voltage: phase-phase, phase-neutral (accuracy 0.5%);
– Power: active, reactive, apparent (accuracy 2%);
– Energy: active, reactive, apparent (accuracy 2%);
– Frequency (accuracy 0.2%);
– Power factor by phase and total;
– Peak factor.
Maximum values and values register
The Ekip Touch unit is able to supply the measurement trend of certain parameters
over a settable period of time such as: average power, maximum power,
maximum and minimum current, maximum and minimum voltage. The values of
the last 24 time intervals are recorded in the unit with a relative timestamp and
can be consulted directly from the display or remotely using one of the available
communication protocols. The communication can also be used to synchronize the
recording time interval.
Data logger
Ekip Touch is always supplied with the exclusive Data Logger (register) function that
stores with high sampling frequency the instantaneous values of all the measurements
in two memory buffer registers. The data can be easily downloaded by the Ekip
Connect unit and transferred to any personal computer. This enables the current and
voltage waveforms to be analyzed for rapid fault analysis. The function continuously
stores and stops recording, with a selectable delay, whenever the event set by the
user occurs (e.g. trip or alarm). In this manner, it is possible to analyze the complete
evolution of the fault: from the start to its complete elimination.
ABB catalogue | 1SDC200023D0201 | 3/15
Emax2_cap03.indd 15
15/04/2013 16:46:02
Protection trip units for power distribution
Ekip Touch
Information on trip and opening data
If a trip occurs, Ekip Touch stores all the information that is required for rapid
identification and elimination of the causes:
– Protection tripped
– Opening data (current, voltage or frequency)
– Time-stamping (data, time and consecutive opening number)
3
1SDC200471F001
If the iTest key is pressed, the trip unit displays all these data directly on the display.
No auxiliary supply is required. The information is also available to the user with the
circuit-breaker open or without current flow, due to the battery installed inside the unit.
Maintenance indicators
A complete set of information about the circuit-breaker and its operation is available
for effective fault analysis and preventive scheduling of maintenance. All the
information can be seen from the display or from a PC using a communication unit.
In particular:
– Date, time, fault current by phase and type of protection tripped over the last 30
trips;
– Date, time and type of operation of the last 200 events (example: opening/closing
of circuit-breaker, pre-alarms, editing of settings, ect.);
– Number of operations of the circuit-breaker: divided into mechanical operations
(no current), electrical operations (with current) and protection function (trip);
– Contact wear estimated in function of the number and type of openings;
– Total operating time of the circuit-breaker with circulating current;
– Date and time of the last maintenance session, scheduling of the next
maintenance session;
– Circuit-breaker identifying data: type, serial number, firmware version, device
name assigned by the user.
All the information can be viewed directly from the display and from a Smartphone,
Tablet (with Ekip Bluetooth) or PC using the front port of the trip unit or the system
communication.
3/16 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 16
15/04/2013 16:46:02
Watchdog
All of the trip units in the SACE Emax 2 family ensure high reliability because of an electronic circuit that periodically controls
continuity of the internal connections (trip coil, rating plug and each current sensor). In the event of an alarm, a message is
shown on the display, and if it is set during the installation phase, the trip unit can command the opening of the circuit-breaker.
If a protection function intervenes, Ekip Touch always checks that the circuit-breaker has been opened by auxiliary contacts
that indicate the position of the main contacts. Otherwise, Ekip Touch indicates an alarm (ANSI BF code - Breaker Failure) to
be used to command the opening of the circuit-breaker located upstream.
Ekip also contains self-protection that preserves the correct operation of the unit against abnormal temperatures (OT) inside
the protection trip unit. The user disposes of the following indications or controls:
3
– “Warning” LED for temperature below -20°C or above +70 °C, at which the trip unit operates correctly with the display
switched off
– “Alarm” LED for temperature outside the operating range, at which the trip unit commands the opening of the circuit-breaker
(if set during the configuration phase).
1SDC200472F001
User interface
All Ekip Touch operations are simple and intuitive due to the wide graphic colour
touchscreen display. For example, all the main information is listed on one page
(settable by default), thus enabling the state of the installation to be identified rapidly:
maximum current, maximum voltage, active, reactive, apparent power and energy.
In addition, the use of Ekip Touch is further simplified by the possibility of scrolling
through the menu and reading the alarms in one of the languages that can be
set directly from the display: Italian, English, German, French, Spanish, Chinese,
Russian, Turkish and Thai.
The home pushbutton enables you to return, at any moment, to the main page and
the iTest key enables the information to be viewed after a circuit-breaker trip and test.
As in the previous generation of trip units, a password system is used to manage
“Read” or “Edit” modes. The default password, 00001, can be edited by the user.
The protection parameters (curve and trip thresholds) are settable in “Edit” mode
whereas it is always possible to consult the information in “Read” mode.
1SDC200473F001
On the front of the trip unit there are also two LEDs: a pre-alarm LED (square yellow
LED) and an alarm LED (red triangular LED); a message on the display always
accompanies the flashing of the LEDs for clear identification of the type of event.
The list of all the alarms active at that moment can be viewed by simply touching
the display on the white strip in the bottom left of the alarms zone.
Ekip Touch is also supplied with a front port that permits a temporary connection to
devices for test, supply or communication (for example Ekip T&P).
ABB catalogue | 1SDC200023D0201 | 3/17
Emax2_cap03.indd 17
15/04/2013 16:46:03
Protection trip units for power distribution
Ekip Touch
3
Communication
Communication modules that can be installed inside the circuit-breaker enable Ekip Touch to be integrated into the most
modern supervision systems with protocols:
– IEC 61850
– Modbus TCP
– Modbus RS-485
– Profibus
– Profinet
– DeviceNet
– EtherNet/IP
The integration into communication systems enables measurements, statuses and alarms to be programmed and viewed by
remote functions. If the circuit-breaker has to be opened and closed remotely, the Ekip Com Actuator module can be installed
in the circuit-breaker front, in the right-hand accessories chamber.
For each circuit-breaker, several communication modules with different protocols can be used simultaneously; for example, this
enables the circuit-breaker to be connected to the Ekip link system to obtain local supervision from the front of the switchgear
and to simultaneously integrate it into a communication network. In addition, for applications requiring very high reliability, up
to two modules of the same protocol can be inserted by use of the redundant version that enables two different addresses to
communicate on the same bus.
Test function
For circuit-breaker testing it is possible to use the test port and the iTest key positioned on the front of the protection trip unit.
The available functions are:
– trip test, test of the display and of the LEDs and check of absence of alarms detected by the watchdog function using Ekip
TT (always supplied with Ekip Touch);
– test of the single protection functions and saving of the report, in addition to the trip test and test of the display, using Ekip
T&P;
– test of the battery with the circuit-breaker switched off by pressing the iTest key.
3/18 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 18
15/04/2013 16:46:03
Supply
The Ekip Touch protection trip unit is self-supplied by the current sensors and does not require an external supply for the
basic protection functions or for the alarm indication functions. All protection settings are stored in a non-volatile memory that
maintains the information, even without a power supply. To activate the indication functions the ammeter and the display, a 100A
three-phase current suffices.
An auxiliary supply can easily be connected. The Ekip Supply module can be connected to supplies of both direct current and
alternating current to activate additional functions such as:
– using the unit with circuit-breaker open;
– using additional modules such as Ekip Signalling and Ekip Com;
– connection to external devices such as Ekip Multimeter and Ekip Control Panel;
– recording the number of operations;
– G protection with values below 100A or below 0.2 In;
– zone selectivity;
– Gext and MCR protection functions.
Supply
Ekip Supply
Nominal voltage
24-48V DC
110-240V AC/DC
Voltage range
21.5-53V DC
105-265V AC/DC
Rated power (including modules)
10W max.
10W max.
Inrush current
~10 A for 5 ms
~10 A for 5 ms
3
The Ekip Supply module allows the cartridge modules to be used in the terminal box area. Otherwise, the trip unit can be
supplied by means of a galvanically isolated 24 VDC auxiliary voltage.
The Ekip Measuring Pro module can supply the Ekip Touch trip unit with line voltage above 85V. In addition, if the module is
installed with voltage pick-ups on the supply side, the trip unit can be used even if the circuit-breaker is open.
The Ekip Touch protection trip unit is also supplied with a battery that enables the cause of the fault to be indicated after a trip,
without a time limit. In addition, the battery enables date and time to be updated, thus ensuring the chronology of the events.
When Ekip Touch is operating, it uses an internal control circuit to indicate automatically that the battery is flat. On the other
hand, when the unit is switched off the battery test can be run by simply pressing the iTest key.
ABB catalogue | 1SDC200023D0201 | 3/19
Emax2_cap03.indd 19
15/04/2013 16:46:03
Protection trip units for power distribution
Ekip Hi-Touch
Characteristics
The Ekip Hi-Touch of SACE Emax 2 is a high-performance multifunction unit that is
extraordinarily versatile and can be used in even the most complex installations. Ekip
Hi-Touch, in fact, features exclusive functions such as: directional protection, restricted
earth fault and dual setting of the protections. In addition, Ekip Hi-Touch is supplied
3 with the exclusive Network Analyzer function that can monitor the quality of the power
absorbed by the installation in accordance with existing standards.
Ekip Hi-Touch boasts all the features of Ekip Touch; as standard, it features the measuring and protection module Ekip
Measuring Pro and can also be fitted, like Ekip Touch, with the additional features provided by the internal modules and by the
external accessories.
The front interface of the unit, which is common to Ekip Touch, is extremely simply because of the touchscreen colour display;
it is able to show measurements, bar graphs and sine curves of the different electrical values.
The unit is available in the versions:
– Ekip Hi-Touch LSI
– Ekip Hi-Touch LSIG
2
3
4
5
1
6
8
Key:
5. Home pushbutton to return to home page
1. Wide high-resolution colour touchscreen display
2. Power-on LED indicating correct operation
6. Pushbutton for test and for indicating cause of
the trip
3. Pre-alarm LED
7. Test and programming connector
4. Alarm LED
8. Ekip Measuring Pro module, with relative LED
power on
1SDC200470F001
1SDC200474F001
7
3/20 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 20
15/04/2013 16:46:03
Protection functions
The Ekip Hi-Touch trip unit has the following protection functions, which it shares with Ekip Touch:
– Overload (L – ANSI 49);
– Time-delayed overcurrent (S – ANSI 51 & 50TD);
– Thermal memory;
– Instantaneous overcurrent (I – ANSI 50);
– Closing on short-circuit (MCR);
– Earth fault (G – ANSI 51N & 50NTD);
– Earth fault on toroid (G ext – ANSI 51G & 50GTD)
– Neutral protection;
– Start-up function;
– Zone selectivity for functions S and G (ANSI 68);
– Current unbalance (IU – ANSI 46);
– Undervoltage (UV – ANSI 27);
– Overvoltage (OV – ANSI 59);
– Underfrequency (UF – ANSI 81L);
– Overfrequency (OF – ANSI 81H);
– Voltage unbalance (VU – ANSI 47);
– Residual current (Rc – ANSI 64 & 50NTD);
– Reverse active power (RP – ANSI 32R);
– Synchrocheck (SC – ANSI 25, optional);
– Cyclical direction of the phases (ANSI 47);
– Power factor (ANSI 78);
– Current thresholds;
– Power Controller function (optional).
3
The following protections are also available:
Second time-delayed overcurrent protection (S2 – ANSI 50TD): in addition to the standard protection
S, a second (excludible) time-constant protection is available that enables two independent thresholds to
be set in order to ensure precise selectivity, especially in highly critical conditions.
protection zone
∆
Y
64REF
Second protection against earth fault (ANSI 50GTD/51G & 64REF): whereas with Ekip Touch the
user has to choose between implementation of the protection G by internal current sensors (calculating
the vector sum of the currents) or G ext external toroids (direct measurement of the earth fault current),
Ekip Hi-Touch offers the exclusive feature of simultaneous management of both configurations by two
independent earth fault protection curves. Owing to this characteristic, the trip unit is able to distinguish
a non-restricted earth fault and then activate the opening of Emax 2, from a restricted earth fault, and to
thus command the opening of the medium voltage circuit-breaker.
Another possible configuration is with the residual current protection replacing the Gext protection, whilst the
G protection remains active. The residual current protection is activated in the presence of the residual current
rating-plug and of the toroid.
ABB catalogue | 1SDC200023D0201 | 3/21
Emax2_cap03.indd 21
15/04/2013 16:46:03
Protection trip units for power distribution
Ekip Hi-Touch
Directional overcurrent (D – ANSI 67): the protection is able to recognize the direction of the current
during the fault period and thus detect if the fault is upstream or downstream of the circuit-breaker. The
protection, with fixed time trip curve (t=k), intervenes with two different time delays (t7bw and t7fw),
according to the current direction. In ring distribution systems, this enables the distribution portion to be
identified in which the fault occurred and to disconnect it while maintaining the operation of the rest of the
installation.
3
Generator
LOAD B
LOAD C
LOAD A
Forward
power flow
Backward
power flow
FAULT
Zone selectivity for protection D (ANSI 68): enables the possibility to connect circuit-breakers among
them, that in case of fault rapidly isolate the fault area, disconnecting the installation only at the level
nearest to the fault, maintaining the operation of the rest of the installation. The function is particularly
useful in ring and grid installations where, in addition to the zone, it is also essential to define the
flow direction of the power that supplies the fault. It is possible to enable directional zone selectivity
alternatively to the zone selectivity of the protections S and G, and in the presence of an auxiliary supply.
Start-up function for protection D: enables higher trip thresholds to be set at the outgoing point, as
available for protections S, I and G.
t
Second protection against undervoltage and overvoltage (UV2 and OV2 – ANSI 27 and 59): enables
two minimum and maximum voltage thresholds to be set with different delays in order to be able to
discriminate, for example, between voltage dip transients due to the start-up of a motor and an actual fault.
U9
t9
U16
t16
V
t
Second protection against underfrequency and overfrequency (UF2 and OF2 – ANSI 87L and 87H):
enables two minimum and maximum frequency thresholds to be set simultaneously. For example, only an
alarm can be set to be tripped when the first threshold is reached, and the circuit-breaker can be set to
be opened when the second threshold is reached.
f17
f12
t17
t12
f
Dual setting of protections: Ekip Hi-Touch can store a set of alternative parameters for all protections.
This second series (set B) can replace, if necessary, the default series (set A) by an external control.
The control can be given when the network configuration is edited, for example when an emergency
source is activated in the system, changing the load capacity and the short-circuit levels. Another typical
application is protecting the operator opposite the switchgear against the electric arc. In this case,
protection delays are minimized to safeguard the operator (Set A), whereas in the absence of an operator
the protections are set to ensure selectivity with the circuit-breakers downstream (Set B). It is possible to
activate series B by:
–
–
–
–
Digital input available with an Ekip Signalling module;
Communication network, by means of one of the Ekip Com communication modules;
Directly from the Ekip Hi-Touch display;
By a settable internal time, after the circuit-breaker has closed.
3/22 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 22
15/04/2013 16:46:04
Measurements
The Ekip Hi-Touch trip unit offers a complete series of measurements, common to Ekip Touch:
– Measurements and counters: currents, voltage, power, energy;
– Maximum values and value log;
– Data logger;
– Information on the trip and opening data;
– Maintenance indicators.
3
Ekip Hi-Touch integrates the exclusive Network Analyzer function, which analyzes the quality of energy consumed by the
installation, in accordance with the provisions of international standards EN50160 and IEC 61000-4-30, in terms of harmonic
content, average value and long or short term changes in voltage. These events can cause malfunctions in the switchgear and
a reduction in their lifespan, as well as increasing losses and reducing the energy efficiency of the installation.
It is therefore increasingly important to assess the quality of the energy and the economic impact it has on the productive
process, so that the appropriate preventive and corrective actions can be taken. With Ekip Hi-Touch, the causes of an increase
in power lost in transformers or motors, or a reduction in the lifespan of cables and capacitors, can be identified without the
need to install any external instrumentation.
The Network Analyzer function performs continuous monitoring of the quality of energy, and shows all results through a display
or communication module. In particular:
– Hourly average voltage value: in accordance with international standards, this must remain within 10% of the rated value,
but different limits can be defined according to the needs of the installation. The positive sequence voltage is obtained from
the three line voltages and compared with the limits. If the limits are exceeded, Ekip Hi-Touch generates a signalling event. The
quantity of these events is stored in a suitable counter. The counter values are available for each of last 7 days, as well as the
total. The measures availabe are the positive and negative sequence voltages and positive and negative sequence currents of
the last interval monitored. The time of the calculation of the average values can be set between 5 minutes and 2 hours.
– Interruptions / short dips in voltage (voltage interruptions / voltage dip): if the voltage remains below the threshold for more
than 40ms, Ekip Hi-Touch generates an event that is counted in a dedicated log. The voltage is monitored on all lines.
– Short voltage spikes (voltage transients, spikes): if the voltage exceeds the threshold for 40ms, set for a pre-determined
time, Ekip Hi-Touch generates an event that is counted.
– Slow voltage sags and swells (voltage sag / voltage swell): when the voltage goes outside the range of acceptable limit values
for a time greater than the one set, Ekip Hi-Touch generates an event that is counted. Three values can be configured for
voltage sags and two for voltage swells, each of which associated to a time limit: this enables us to verify whether the voltage
remains within a curve of values that are acceptable by equipment such as computers. The voltage is monitored on all lines.
– Voltage unbalances: if the voltages are not equal or the phase displacements between them are not exactly 120°, an
unbalance occurs, which is manifested with a negative sequence voltage value. If this limit exceeds the threshold value set,
an event is stored which is counted.
– Harmonic analysis: the harmonic content of voltages and currents, measured to the 50th harmonic, as well as the value of
total harmonic distortion (THD), is available in real time on the display or through the communication modules. Ekip Hi-Touch
also generates an alarm if the THD value or the magnitude of at least one of the harmonics exceeds the values set.
The voltage is monitored on all lines and currents on all phases.
All information can be displayed directly on the screen or on a smartphone, tablet or PC using the front port of the trip unit (with
Ekip Bluetooth) or installation communication.
Other functions
Ekip Hi-Touch integrates all the features in terms of user interface, communication, test and supply described for Ekip Touch
equipped with Ekip Measuring Pro.
ABB catalogue | 1SDC200023D0201 | 3/23
Emax2_cap03.indd 23
15/04/2013 16:46:04
Protection trip units for generators
Ekip G Touch
Characteristics
Ekip G Touch by SACE Emax 2 is the new protection trip unit designed for
use in applications with generators, such as Genset, cogeneration and marine
applications, in conformity to international standards IEC 60034-1 and IEEE
C37.102. Ekip G Touch has been approved by the main shipping registers and
3 enables the number of components installed, such as external protection devices,
current sensors, voltage transformers and the relative cabling, to be reduced.
The reductions allow the installation to be significantly simplified. In addition, all
the protection functions can be tested individually, using the Ekip T&P device that
enables the function to be tested before commissioning.
The unit is available in the Ekip G Touch LSIG version and features all the characteristics provided by Ekip Touch. The Ekip
Measuring Pro measuring and protection module is supplied as standard and, like Ekip Touch; the functions can be increased
further using the internal modules and the external accessories.
The front interface of the unit, which is common to the Ekip Touch family, is characterised by a wide, high resolution
touchscreen display that is simple to use and displays measurements and alarms clearly and accurately.
2
3
4
5
1
6
8
Key:
5. Home pushbutton to return to home page
1. Wide, high resolution touchscreen display
2. Power-on LED indicating correct operation
6. Pushbutton for test and for indicating cause of
the trip
3. Pre-alarm LED
7. Test and programming connector
4. Alarm LED
8. Ekip Measuring Pro module with relative poweron LED
1SDC200470F001
1SDC200475F001
7
3/24 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 24
15/04/2013 16:46:05
Protection functions
The Ekip G Touch trip unit provides all the protection functions of Ekip Touch and, in addition, provides a series of dedicated
generator protections. If Ekip is tripped, it opens the circuit-breaker and prevents it from closing again until it has been reset
manually or electrically by the operator (lockout relay – code ANSI 86).
The trip unit is provided with the following protection functions:
– Overload (L – ANSI 49);
– Time-delayed overcurrent (S – ANSI 51 & 50TD);
– Thermal memory;
– Instantaneous overcurrent (I – ANSI 50);
– Closing on short circuit (MCR);
– Earth fault (G – ANSI 51N & 50NTD);
– Earth fault on toroid (G ext – ANSI 51G & 50GTD)
– Neutral protection;
– Start-up function;
– Zone selectivity for functions S and G (ANSI 68);
– Current unbalance (IU – ANSI 46);
– Undervoltage (UV – ANSI 27);
– Overvoltage (OV – ANSI 59);
– Underfrequency (UF – ANSI 81L);
– Overfrequency (OF – ANSI 81H);
– Voltage unbalance (VU – ANSI 47);
– Differential ground fault (Rc – ANSI 87N);
– Reverse active power (RP – ANSI 32R);
– Synchrocheck (SC – ANSI 25, optional);
– Cyclical direction of phases (ANSI 47);
– Power factor (ANSI 78);
– Current thresholds;
– Power Controller function (optional).
L1 L2 L3
3
Differential ground fault (Rc - ANSI 87N): protects against internal earth fault on generator winding. It is
required that the toroid hugs the active conductors and the ground conductor. Rc protection is integrated by
a dedicated residual current rating plug and the external toroid.
ABB catalogue | 1SDC200023D0201 | 3/25
Emax2_cap03.indd 25
15/04/2013 16:46:05
Protection trip units for generators
Ekip G Touch
The specific functions for generator protections are described below, for each of which it is possible to choose the operating
mode: active, only alarm or deactivated. All the voltage and frequency protections also operate when the circuit-breaker is
open, enabling the fault to be identified before the closing of the circuit-breaker.
t
Voltage controlled overcurrent protection (S(V) - ANSI 51V): protection from maximum current with
constant trip time (t = k) that is sensitive to the voltage value. The set current threshold, following a
voltage drop, decreases by steps or linearly.
1
3
Ks
t20
KsxI20
I
I20
In step mode (controlled mode) the protection is tripped at the set threshold (I20) if the voltage is above
U, whereas it is tripped at the lower threshold of the factor Ks (I20 * Ks) if the voltage is below U.
K
1
Ks
V
UI
U
On the other hand, in linear mode (restrained mode) two voltage limits are selected within which the
protection is tripped at the set threshold (I20) reduced by the factor K corresponding to the measured
voltage. The variation of the factor K is proportional to the voltage, and for voltages greater than the upper
threshold (Uh) the threshold I20 works, whereas for voltages below the lower threshold (UI) the minimum
threshold (I20 * Ks) applies.
K
1
Ks
UI
V
Uh
2
V23
V12
α
3
Residual overvoltage (RV – ANSI 59N): with constant trip time (t = k), protects against insulation loss in
systems with insulated neutral or with neutral earthed with impedance.
α
V31
1
3/26 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 26
15/04/2013 16:46:05
Q
P
Loss of field or reverse reactive power (RQ – ANSI 40 or 32RQ): with constant trip time (t = k), is
tripped when the total reactive power absorbed by the generator exceeds the set threshold. It is possible
to select the constant threshold (k=0) or a function of the delivered active power of the generator (kz0).
TRIP
3
Reactive overpower (OQ – ANSI 32OF): with constant trip time (t = k), the function is tripped when
reactive power exceeds the set threshold in the generator to network direction.
t
Q27
t27
Q
Active overpower (OP – ANSI 32OF): with constant trip time (t = k), the function is tripped when the
active power exceeds the threshold set in the delivering direction of the generator.
t
P26
t26
P
Active underpower (UP – ANSI 32LF): with constant trip time (t = k), the function is tripped when the
active power delivered by the generator is lower than the set threshold. It is possible to disable the
protection temporarily, to manage the start-up phase, by setting a time window from the closing of the
circuit-breaker, by using an electric signal or via incoming communication to a relay.
t
P23
t23
P
ABB catalogue | 1SDC200023D0201 | 3/27
Emax2_cap03.indd 27
15/04/2013 16:46:05
Protection trip units for generators
Ekip G Touch
3
Measurements
The Ekip G Touch trip unit provides a complete series of measurements, which are common to Ekip Touch:
– Measurements and meters: currents, voltage, power, energy, frequency;
– Maximum values and values register;
– Data logger;
– Information on trip and opening data;
– Maintenance indicators.
All the information can be viewed directly from the display of the trip-unit, by means of the external Ekip Multimeter display or
by Smartphone, Tablet or PC using the front port of the trip unit (with Ekip Bluetooth) or the system communications.
Other functions
Ekip G Touch provides the same characteristics in terms of user interface, communication, test and power supply described for
Ekip Touch equipped with Ekip Measuring Pro.
3/28 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 28
15/04/2013 16:46:05
Protection trip units for generators
Ekip G Hi-Touch
Characteristics
SACE Emax 2’s Ekip G Hi-Touch is the new benchmark for the protection of low
voltage electric generators. It provides optimum protection, even in complex
installations, due to exclusive functions such as protection against frequency creep
and maximum directional current.
3
Ekip G Hi-Touch, like all Hi-Touch trip units, is supplied as standard with the Ekip Measuring Pro measuring and protection
module and enables an independent second set of protections to be set. In addition, the Network Analyzer function enables it
to monitor the quality of the power delivered by the generator.
Ekip G Hi-Touch is available in the LSIG version and ensures all the protection, measuring and control functions of Ekip HiTouch and the specific protections for Ekip G Touch generators. The user interface and the accessories are common to the rest
of the family.
2
3
4
5
1
6
1SDC200470F001
1SDC200476F001
7
8
Key:
5. Home pushbutton to return to home page
1. Wide, high resolution touchscreen display
2. Power-on LED indicating correct operation
6. Pushbutton for test and for indicating cause of
the trip
3. Pre-alarm LED
7. Test and programming connector
4. Alarm LED
8. Ekip Measuring Pro module with relative poweron LED
ABB catalogue | 1SDC200023D0201 | 3/29
Emax2_cap03.indd 29
15/04/2013 16:46:06
Protection trip units for generators
Ekip G Hi-Touch
3
Protection functions
The Ekip G Hi-Touch trip unit is provided with the following protection functions, common to Ekip Hi-Touch:
– Overload (L – ANSI 49);
– Time-delayed overcurrent (S – ANSI 51 & 50TD);
– Time-delayed overcurrent, second threshold (S2 – ANSI 50TD);
– Thermal memory;
– Instantaneous overcurrent (I – ANSI 50);
– Directional overcurrent (D – ANSI 67);
– Voltage controlled overcurrent protection (S(V) – ANSI 51V);
– Closing on short circuit (MCR);
– Earth fault (G – ANSI 51N & 50NTD);
– Second protection against earth fault (ANSI 50GTD/51G & 64REF);
– Earth fault on toroid (Gext – ANSI 51G & 50GTD);
– Neutral protection;
– Start-up function;
– Zone selectivity for functions S and G (ANSI 68);
– Zone selectivity for directional protection D (ANSI 68)
– Start-up function for protection D;
– Current unbalance (IU – ANSI 46);
– Undervoltage (UV – ANSI 27);
– Undervoltage, second threshold (UV2 – ANSI 27);
– Overvoltage (OV – ANSI 59);
– Overvoltage, second threshold (OV2 – ANSI 59);
– Underfrequency (UF – ANSI 81L);
– Underfrequency, second threshold (UF2 – ANSI 81L);
– Overfrequency (OF – ANSI 81H);
– Overfrequency, second threshold (OF2 – ANSI 81H);
– Voltage unbalance (VU – ANSI 47);
– Residual overvoltage (RV – ANSI 59N);
– Differential ground fault (Rc – ANSI 87N);
– Loss of field or reverse reactive power (RQ – ANSI 40 or 32R);
– Reverse active power (RP – ANSI 32R);
– Reactive overpower (OQ – ANSI 32OF);
– Active overpower (OP – ANSI 32OF);
– Active underpower (UP - ANSI 32LF);
– Synchrocheck (SC – ANSI 25, optional);
– Cyclical direction of phases (ANSI 47);
– Power factor (ANSI 78);
– Current thresholds;
– Dual setting of protections;
– Power Controller function (optional).
3/30 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 30
15/04/2013 16:46:06
In addition, the following protections are also available:
f(Hz)
Rate of change of frequency (ROCOF – ANSI 81R): enables both positive and negative frequency
variations to be detected rapidly. The protection is constant and is tripped when the frequency variation
in Hz/s is greater than the set threshold.
frequency
after failure
failure
50/60Hz
frequency
after failure
3
Time
t
Second protection against voltage controlled overcurrent protection (S2(V) - ANSI 51V): available in
addition to the protection S(V), enables total selectivity to be achieved in all installations.
1
Ks
t21
Ks
t20
I
KsxI20 I20 I21
KsxI21
Q
kq
kq2
P
Second protection against loss of field or reverse reactive power (RQ – ANSI 40 or 32R): enables
the generator’s de-energization curve to be followed very accurately, thereby avoiding any unnecessary
disconnection.
Q25
Q24
Measurements
The Ekip G Hi-Touch trip unit provides all the measurements available with Ekip Hi-Touch:
– Network Analyzer, in conformity to EN50160 and IEC 61000-4-30;
– Measurements and meters: currents, voltage, power, energy, frequency;
– Maximum values and values register;
– Data logger;
– Information on trip and opening data;
– Maintenance indicators.
Other functions
Ekip G Hi-Touch has all the features of Ekip Touch equipped with Ekip Measuring Pro in terms of user interface, communication,
test and power supply.
ABB catalogue | 1SDC200023D0201 | 3/31
Emax2_cap03.indd 31
15/04/2013 16:46:06
Protection trip units for power control
Ekip Power Controller
The exclusive Ekip Power Controller function, patented by ABB and available on
new SACE Emax 2 circuit-breakers, monitors installation loads and generators,
permitting the power consumed to be limited and allowing savings on electricity
bills.
3
Ekip Power Controller, which can be used with all Ekip Touch trip units of the Emax 2 series, effectively helps to improve energy
efficiency by managing the entire low voltage electrical system. It is, in fact, able to adapt the demand for power according to
the availability of the energy source, the time of day and the costs indicated in the current pricing plan.
In this way Ekip Power Controller is able to maintain power consumption within the limits defined, thereby optimizing the costs
of managing the installation and reducing emissions.
Controllable
generator
Controllable
load
Non-controllable
load
Non-controllable
generator
Control
circuit
Transformer
Energy meter
1SDC200477F001
Emax 2 with
Ekip Power
Controller
3/32 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 32
15/04/2013 16:46:06
Distinctive features
Reduction of energy costs with minimum impact. The loads are disconnected from the power supply for short periods, in
the minimum number necessary and in a fixed order of priority, enabling power consumption peaks to be limited. This allows
the contract drawn up with the energy provider to be renegotiated, reducing the power allocated, with a consequent reduction
in total energy costs.
Power limited only when necessary. Ekip Power Controller manages up to four different time bands: it is therefore possible
to respect a particular power limit according to whether it is during the day (peak) or night (off peak). In this way, consumption
during the day when rates are at their highest can be limited.
3
Simple to install. Ekip Power Controller allows the installation to be managed efficiently with a simple architecture. Thanks to
a patented design, it is sufficient to measure the total power of the installation without having to measure the power consumed
by each load. Installation costs and times are thereby reduced to a minimum.
Ready to use. Ekip Power Controller does not require the writing, implementation and testing of complicated programmes for
PLC or computer because the logic has already been implemented in the protection unit and is ready to use; it is sufficient to
set the installation parameters from a smartphone or directly from the circuit-breaker display.
Improvement of the efficiency of the electrical system. Ekip Power Controller significantly helps to flatten the load curve,
limiting the use of peaking power plants in favour of base load power plants with greater efficiency.
Graph of daily load
Power (kW)
600
Load graph
Average P
P 15 min
500
P1h
400
300
200
100
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Time
Perfect integration into intelligent networks. Thanks to integrated communication modules, Ekip Power Controller can
receive the maximum absorbable power directly from the medium voltage control system, determining consumption for the next
15 minutes. Ekip Power Controller, according to the information received, manages the switching off of non-priority loads or
the switching on of reserve generators. Ekip Power Controller gives maximum priority to non-programmable preferred energy
sources, such as wind and solar, and they are therefore considered uninterruptable. In the event the production of internal
power to the controlled network is reduced, due, for example, to decreased production of solar power, Ekip Power Controller
will disconnect the necessary loads to respect the consumption limit set.
Perfect integration in self-generation systems. This benefit is used, for example, in installations with a system of cogeneration.
Ekip Power Controller controls the total consumption drawn from the electrical network, interrupting non-indispensable loads
when production is reduced and reconnecting them when generator power is sufficient to not exceed limits. There are multiple
advantages: reduction in energy costs, maximum use of local production and greater overall energy efficiency.
ABB catalogue | 1SDC200023D0201 | 3/33
Emax2_cap03.indd 33
15/04/2013 16:46:06
Protection trip units for power control
Ekip Power Controller
Operating principle
3
Ekip Power Controller is an advanced system of control in real time that limits the average power consumed in each time range
to a maximum, pre-determined value. This is achieved by delaying, only when necessary, the operation of controllable loads,
which are then put back into operation as soon as possible without exceeding the limits of power set. In each instance, Ekip
Power Controller optimizes the number of deactivated loads on the basis of a determined order of priority, constantly seeking
to supply the most extensive part possible of the installation. If controllable generators are present such as, for example, diesel
generators, Ekip Power Controller controls their switching on and off to limit the peak of power consumed. The types of loads
that can be interrupted for a few minutes with a limited impact are many and vary according to the application, for example:
– industrial ovens, fridges;
– ventilation or air compression systems;
– electric car charging systems;
– electrical air conditioning/heating of corridors, stairways and passageways;
– electric kitchens in hotels/hospitals;
– swimming pool heating systems and circulation pumps.
The method of calculation
Ekip Power Controller controls the maximum power consumed by the installation,
utilizing the same method as that used for fiscal metering, thereby achieving
savings on the component connected to maximum power ($/kW) on electricity bills.
The power consumed is calculated by the energy meter as an average value over
pre-determined time periods such as, for example, 15 minutes, or even 1 hour.
The user therefore pays the same bill both in the event he consumes 1MW
continuously (profile 1) or 2MW for 50% of the time and 0MW for the remaining 50%
(profile 2), since the average power is the same.
Power
Profile 2
2MW
Profile 1
1MW
Average
power
0 min
30 min
60 min
Time
Estimation of consumption
Ekip Power Controller uses this principle together with a predictive algorithm that estimates, moment by moment, power at
the end of the period in order to decide whether to disconnect or connect loads and generators. This enables brief transient
requests for high power to be tolerated, such as, for example, the starting up of motors, without causing the disconnection of
loads as soon as the power exceeds the threshold set.
The operations of connection and disconnection therefore depend on the consumption from the beginning of the period up to
the present moment: for example, if during the first few minutes of the period of reference consumption was very high, Ekip
Power Controller will disconnect a greater number of loads in the minutes after; if, on the other hand, the initial consumption
was low, it will leave a greater number of loads in operation.
3/34 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 34
15/04/2013 16:46:06
Management of loads
According to the consumption estimate at the end of the period, Ekip Power Controller will take different actions:
– if the value estimated is greater than the power set as a target, Ekip Power Controller makes the decision to disconnect one
of the loads controlled from the power supply, or to connect a generator;
– if the value estimated is equal or slightly less than the average power set as a target, Ekip Power Controller makes the
decision to leave the conditions of the controlled loads and generators unchanged;
– if the value estimated is significantly lower than the average power set as a target, Ekip Power Controller makes the decision
to reconnect one of the loads controlled to the power supply, or switch off a generator if one or more of these have been
switched on previously.
This operation is carried out cyclically each time by calculating a new estimate: therefore, if the estimate of power consumed
continues to be too high despite the fact that a load has been disconnected, Ekip Power Controller will proceed to disconnect
another and so on, until the power limit is respected. In this way, the number of connected or disconnected loads varies
dynamically, and always with the guarantee that only the minimum number needed to respect the power limit are disconnected.
3
Priority of loads
If the decision made is to disconnect or re-connect one of the loads controlled, Ekip Power Controller proceeds according to
an established order: the load indicated as the first will be that of least importance, or that for which a temporary period of
deactivation is acceptable; the load indicated as the second will be the next one in order of importance, and so on. The loads
that have been disconnected in that order will be later re-connected in the reverse order, beginning with the load that is most
important for the installation. In this way, the impact on the production process can be minimized, limiting the disconnection
time for loads of the highest priority. Furthermore, by gradually connecting and disconnecting the loads in order of priority,
voltage imbalances and consumption peaks affecting the network are avoided.
Protection of the installation
Ekip Power Controller can be integrated perfectly into the installation’s protection devices. In fact, if one of the controlled
circuit-breakers opens due to an overcurrent or by manual operation, Ekip Power Controller considers the load unavailable until
the operator resets it, making it available again. In this way, safe operation of the installation is always guaranteed.
ABB catalogue | 1SDC200023D0201 | 3/35
Emax2_cap03.indd 35
15/04/2013 16:46:06
Protection trip units for power control
Ekip Power Controller
Architecture
3
Ekip Power Controller is installed on the main low voltage circuit-breaker, immediately downstream of the transformer and energy
meter. By using the high precision current and voltage sensors located inside the SACE Emax 2, it is able to measure the average
power consumed by the installation, using the same method as that used for fiscal metering, over an established time period. To
control this average power, Ekip Power Controller performs controlled opening and closing of the switching devices.
A Power Controller system consists of:
– a SACE Emax 2 circuit-breaker with Ekip Touch protection trip unit equipped with Ekip Power Controller and Ekip Measuring.
This circuit-breaker is the power controller and meterand implements the Power Controller function, determining the
connection and disconnection of loads;
– up to 15 controlled loads and/or generators. The connection between Ekip Power Controller and users can be achieved:
- with Ekip Signalling modules for connections inside the same switchboard. This allows circuit-breakers or contactors
installed on the power circuit to be commanded directly through available outputs. The opening and closing operations are
always carried out in safety thanks to an input that receives feedback on the state of the device.
- with Ekip Signalling modules by acting on the generator starting circuit or on the control circuit of the loads. This allows, for
example, the consumption of motors powered by drives to be reduced without interrupting the production cycle.
- with Ekip Link communication modules for installations with circuit-breakers in different switchboards. This enables wiring
between switchboards to be simplified to the use of only one EtherNet cable.
09%UHDNHU
(QHUJ\0HWHU
(NLS6XSSO\
NPRGXOH
NPRGXOH
(NLS/LQN
(QHUJ\PHWHUFORFN
NPRGXOH (NLSSRZHU&RQWUROOHU
(NLS7RXFK
;702((
4 6<
4 6<
70
70
1R3ULRULW\ORDGV
1R3ULRULW\ORDGV
0
1R3ULRULW\ORDGV
$FWXDWRU
<2
<&
(NLS6XSSO\
(NLS7RXFK
0
1R3ULRULW\ORDGV
$FWXDWRU
<2
<&
(NLS'LS
0
$FWXDWRU
<2
<&
1SDC200479F001
;702((
(NLS/LQN
(NLS/LQN
9$&
9$&
(NLS6XSSO\
(NLS/LQN
9$&
3ULRULW\ORDGV
In the event that the installation is constructed with a single medium voltage delivery point and two or more transformers in
parallel, Ekip Power Controller can acquire, via Ekip Link, the power measurement carried out by the other Emax 2 devices
present. In this way the power limit can be respected at the medium voltage measuring point, without having to duplicate the
control circuit of the loads.
3/36 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 36
15/04/2013 16:46:07
Installation
Ekip Power Controller is not only simple to implement and use, it is also very flexible thanks to parameters which have been
specially developed to satisfy the needs of all applications.
Installation parameters:
– Power limit: this is the average power that Ekip Power Controller respects, which can be selected in kW directly from the
display.
– Evaluation window: this is the period in which the distributor of electrical energy evaluates the maximum power, which can be
selected within a wide range to respect the local needs of each country.
– Synchronization input: this is used to synchronize the clock inside Ekip with that of the meter. It can also be used to signal a
change in band.
3
Parameters of the user:
– Type of user: can be selected from among load and generator.
– Minimum disconnection time (T off min): this is the minimum time for which a load or generator is not supplied with power
following disconnection. This is useful when you wish to avoid frequent operations on users that are at the top of the priority
list. Ekip Power Controller reconnects the load or generator only after the time set has passed.
– Maximum disconnection time (T off max): this is the maximum time for which no power is permitted. It is required, for
example, in the case of an oven to keep the temperature within the established limits. When the time has passed, Ekip Power
Controller reactivates it automatically, disconnecting, if necessary, a load of a higher priority.
– Minimum connection time (T on min): minimum time for which a load or generator is kept powered following reconnection. It
is useful in the event the generator has a minimum time for which it must remain connected. Until the time set has passed,
Ekip Power Controller will not disconnect the load, connecting, if necessary, loads of a higher priority.
– Time window: this is the hours in the day when a load or generator can be operated. It is useful, for example, in the case of a
canteen that cannot be disconnected during meal times, or a diesel generator that can not be operated at night due to noise
pollution.
– Temporary unavailability: a user can be temporarily deactivated, for example, because it is undergoing maintenance, through
the circuit-breaker display or digital input connected to a manual/automatic selector. The digital input can also be used, for
example, in the case of a fridge, to manage its interruptability: with active input the fridge cannot be disconnected as it is
above the minimum temperature, with inactive input, on the other hand, it can be disconnected.
Power limit
can be set directly in kW
Time bands
up to 4
Synchronization with contactor
•
Evaluation time
5…120 min
Number of loads/generators
up to 15
Priority
from 1 to 15
t on min
1…360 min
t off min
1…360 min
t off max
1…360 min
Temporary disabling input
1 for each device
Controllable devices
load/generator
Type of control
- moulded-case and air circuit-breaker
- modular circuit-breakers
- contactors
- control circuit of load/generator
Type of connections
- wired
- with Ekip Link communication for ACB
ABB catalogue | 1SDC200023D0201 | 3/37
Emax2_cap03.indd 37
15/04/2013 16:46:07
Technical characteristics for protection trip units
Protection functions
ABB Code
ANSI/IEEE C37.2 Function
Code
Threshold
L
49
I1 = 0.4 - 0.42 - 0.45 - 0.47 - 0.5 - 0.52 - 0.55 - 0.57 - 0.6 - 0.62 - 0.65 - 0.67 - 0.7 0.72 - 0.75 - 0.77 - 0.8 - 0.82 - 0.85 - 0.87 - 0.9 - 0.92 - 0.95 - 0.97 - 1 x In
Overload protection
3
Thermal memory
S
51
Tolerance
tripping between 1.05 and 1.2 x I1
Short-circuit selective protection
I2 = 0.6 - 0.8 - 1 - 1.5 - 2 - 2.5 - 3 - 3.5 - 4 - 5 - 6 - 7 - 8 - 9 - 10 x In
Tolerance
± 7% If d 6 x In
± 10% If > 6 x In
Short-circuit selective protection
I2 = 0.6 - 0.8 - 1 - 1.5 - 2 - 2.5 - 3 - 3.5 - 4 - 5 - 6 - 7 - 8 - 9 - 10 x In
Thermal memory
± 7% If d 6 x In
± 10% If > 6 x In
Tolerance
I
G
50
51N
Short-circuit instantaneous protection
I3= 1.5 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 x In
Tolerance
± 10%
Earth fault protection
I4(1) = 0.1 - 0.2 - 0.3 - 0.4 - 0.6 - 0.8 - 1 x In
Tolerance
± 7%
Earth fault protection
I4(1) = 0.1 - 0.2 - 0.3 - 0.4 - 0.6 - 0.8 - 1 x In
Tolerance
± 7%
(1) G protection below 100A or below 0.2 In available with auxiliary supply
(2) The minimum trip time is 1s, regardless of the type of curve set (self-protection)
The tollerances above apply to trip units already powered by the main circuit with current flowing in at least two-phases or an auxiliary power supply. In all other cases the following tollerance values apply
ABB Code
Trip threshold
L
Trip time
Trip between 1.05 and 1.2 x I1
± 20%
S
± 10%
± 20%
I
± 15%
d 60ms
G
± 15%
± 20%
3/38 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 38
15/04/2013 16:46:07
Trip time
Excludibility
Pre Alarm
Trip curve
with I = 3 I1, t1 = 3 - 12 - 24 - 36 - 48 - 72 - 108 - 144 s (2)
No
50 ... 90 I1
Step 1%
t = k / I2
Yes
No
t=k
Yes
No
t = k / I2
Yes
No
Yes
No
t=k
Yes
No
t=k
Yes
No
t = k / I2
Ekip Dip
3
Yes
± 10% If d 6 x In
± 20% If > 6 x In
t2 = 0.1 - 0.2 - 0.3 - 0.4 - 0.5 - 0.6 - 0.7 - 0.8s
The better of the two data:
± 10% or ± 40 ms
with I = 10 In, t2 = 0.1 - 0.2 - 0.3 - 0.4 - 0.5 - 0.6 - 0.7 - 0.8s
± 15% If d 6 x In
± 20% If > 6 x In
Instantaneous
d 30 ms
t4 = 0.1 - 0.2 - 0.4 - 0.8s
The better of the two data:
± 10% or ± 40 ms
t4 = 0.1 - 0.2 - 0.4 - 0.8s
± 15%
ABB catalogue | 1SDC200023D0201 | 3/39
Emax2_cap03.indd 39
15/04/2013 16:46:07
Technical characteristics for protection trip units
Protection functions
ABB Code
ANSI Code
Function
Thereshold
Threshold step
Tripping time
Time Step
L
49
Overload Protection
I1 = 0.4…1 x In
0.001 x In
with I = 3 I1, t1 = 3...144 s
1s
Thermal Memory
3
Tolerance
tripping between
1.05 and 1.2 x I1
Overload Protection
I1 = 0.4…1 x In
Tolerance
tripping between
1.05 and 1.2 x I1
50TD
Time-delayed overcurrent protection
I2 = 0.6...10 x In
68
Zone selectivity
49
S
51
Start up
Activation: 0.1…10 x In
Tolerance
± 7% I d 6 x In
± 10% I > 6 x In
Time-delayed overcurrent protection
I2 = 0.6...10 x In
± 10% I d 6 x In
± 20% I > 6 x In
0.001 x In
with I = 3 I1, t1 = 3...144 s
Standard inverse SI: k=0.14 D=0,02
Very Inverse VI: k=13.5 D=1
Extremely Inverse EI: k=80 D=2
t=k/I4: k=80 D=4
1s
± 10% I d 6 x In
± 20% I > 6 x In
0.1 x In
0.1 x In
t2 = 0.05...0.8s
0.01s
t2sel = 0.04…0.2s
0.01s
Range: 0.1…30s
0.01s
The better of the two data:
± 10% or ± 40 ms
0.1 x In
with I = 10 In, t2 = 0.05...0.8s
0.01s
Thermal Memory
Tolerance
S2
S(V)
50TD
51V
51V
I5 = 0.6...10 x In
0.1 x In
t5 = 0.05...0.8s
0.01s
Start up
Activation: 0.1…10 x In
0.1 x In
Range: 0.1…30s
0.01s
Tolerance
± 7% I5 d 6 x In
± 10% I5 > 6 x In
Voltage controlled overcurrent protection
I20 = 0.6...10 x In
0.1 x In
Step mode (controlled mode)
Ul= 0.2…1 x Un
0.01 x Un
Ks= 0.1…1
0.01
MCR
Ul= 0.2…1 x Un
0.01 x Un
Uh= 0.2…1 x Un
0.01 x Un
Ks= 0.1…1
0.01
± 10%
Voltage controlled overcurrent protection
I21 = 0.6...10 x In
0.1 x In
Step mode (controlled mode)
Ul2= 0.2…1 x Un
0.01 x Un
Ks2= 0.1…1
0.01
Tolerance
50
The better of the two data:
± 10% or ± 40 ms
Tolerance
Linear mode (restrianed mode)
I
± 15% I d 6 x In
± 20% I > 6 x In
Time-delayed overcurrent protection
Linear mode (restrianed mode)
S2(V)
± 7% I2 d 6 x In
± 10% I2 > 6 x In
t20 = 0.05…30s
0.01s
The better of the two data:
± 10% or ± 40 ms
Ul2= 0.2…1 x Un
0.01 x Un
Uh2= 0.2…1 x Un
0.01 x Un
Ks2= 0.1…1
0.01
± 10%
t21 = 0.05…30s
0.01s
The better of the two data:
± 10% or ± 40 ms
Istantaneous overcurrent protection
I3= 1.5...15 x In
0.1 x In
Instantaneous
-
Start up
Activation: 0.1…10 x In
0.1 x In
Range: 0.1…30s
0.01s
Tolerance
± 10%
Closing on short-circuit protection
I3= 1.5...15 x In
Tolerance
± 10%
d 30 ms
0.1 x In
Instantaneous
Activation range: 40…500ms
0.01s
d 30 ms
3/40 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 40
15/04/2013 16:46:07
Excludibility
Excludibility trip Pre-allarm
yes, with rating plug L=off no
50...90% I1
Trip curve
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
t = k / I2
●
●
●
●
●
●
●
●
●
●
●
●
yes
yes, with rating plug L=off no
50...90% I1
yes
no
yes
t1 ß
t=k
●
●
●
●
yes
●
●
●
●
yes
●
●
●
●
●
●
●
●
●
●
●
●
yes
yes
no
t = k / I2
yes
yes
yes
no
t=k
yes
yes
yes
yes
yes
no
no
●
●
●
●
t=k
●
●
●
●
●
●
t=k
3
●
●
●
yes
no
no
t=k
yes
yes
no
no
t=k
●
●
●
●
●
●
●
●
●
●
●
●
Table continued on next page
ABB catalogue | 1SDC200023D0201 | 3/41
Emax2_cap03.indd 41
15/04/2013 16:46:08
Technical characteristics for protection trip units
Protection functions
ABB Code
ANSI Code
Function
Thereshold
Threshold step
Tripping time
Time Step
G
50N TD
Earth fault protection
I4(1) = 0.1...1 x In
0.001 x In
with I > I4, t4 = 0.1…1s
0.05s
68
Zone selectivity
t4sel = 0.04…0,2s
0.01s
Start up
Activation: 0.1…10 x In
0.1 x In
range: 0.1…30s
0.01s
Tolerance
± 7%
Earth fault protection
I4(1) = 0.1...1 x In
Tolerance
± 7%
Earth fault protection
I4(1) = 0.1...1 x In Toroid
0.001 x In Toroid t4 = 0.1…1s
0.05s
Start up
Activation: 0.1…10 x In
0.1 x In
0.01s
Tolerance
± 7%
Earth fault protection
I4(1) = 0.1...1 x In
Tolerance
± 7%
67
Directional overcurrent protection
I7 = 0.6...10 x In
68
Zone selectivity
3
51N
Gext
50G TD
51G
D
IU
46
Rc
64 50N TD
87N
UV
27
UV2
OV
OV2
RV
VU
UF
UF2
OF
27
59
59
59N
47
81L
81L
81H
The better of the two data:
± 10% or ± 40 ms
0.001 x In
with I = 4 In, t4 = 0.1…1s
± 15%
range: 0.1…30s
The better of the two data:
± 10% or ± 40 ms
0.001 x In
with I = 4 In, t4 = 0.1…1s
0.1 x In
0.01s
0.01s
range: 0.1…30s
0.01s
Activation: 0.1…10 x In
± 7% I7 d 6 x In
± 10% I7 > 6 x In
Current unbalance protection
I6= 2…90% In unbalance
Tolerance
± 10%
The better of the two data:
± 10% or ± 40 ms
Residual current protection Differential ground
fault protection
I'n= 3 - 5 - 7 - 10 - 20 - 30A
t'n = 0.06 - 0.1 - 0.2 0.3 - 0.4 - 0.5 - 0.8s
Tolerance
- 20% ÷ 0%
Undervoltage Protection
U8= 0.5….0.98 x Un
Tolerance
± 5%
Undervoltage Protection
U15= 0.5….0.98 x Un
Tolerance
± 5%
Overvoltage protection
U9= 1.02….1.5 x Un
Tolerance
± 5%
Overvoltage protection
U16= 1.02….1.5 x Un
Tolerance
± 5%
Residual overvoltage protection
U22= 0.1….0.5 x Un
Tolerance
± 5%
U14= 2…90% Un unbalance
± 10%
Underfrequency protection
f12= 0.9….0.99 x fn
Tolerance
± 5%
Underfrequency protection
f17= 0.9….0.99 x fn
Tolerance
± 5%
Overfrequency protection
f13= 1.01….1.1 x fn
Tolerance
± 5%
0.1 x In
t7 = 0.2...0.8s
t7sel = 0.13…0.5s
Tolerance
Tolerance
0.01s
± 15%
Start up
Voltage unbalance protection
0.01s
The better of the two data:
± 10% or ± 40 ms
1%In
t6 = 0.5…60s
0.5s
0.06s
0.001 x Un
t8 = 0.05…60s
0.05s
The better of the two data:
± 10% or ± 40 ms
0.001 x Un
t15 = 0.05…60s
0.05s
The better of the two data:
± 10% or ± 40 ms
0.001 x Un
t9 = 0.05…60s
0.05s
The better of the two data:
± 10% or ± 40 ms
0.001 x Un
t16 = 0.05…60s
0.05s
The better of the two data:
± 10% or ± 40 ms
0.001 x Un
t22 = 0.5…60s
0.05s
The better of the two data:
± 10% or ± 40 ms
1%Un
t14 = 0.5…60s
0.5s
The better of the two data:
± 10% or ± 40 ms
0.01 x fn
t12 = 0.2…60s
0.1s
The better of the two data:
± 10% or ± 40 ms
0.01 x fn
t17 = 0.2…60s
0.1s
The better of the two data:
± 10% or ± 40 ms
0.01 x fn
t13 = 0.5…60s
0.1s
The better of the two data:
± 10% or ± 40 ms
3/42 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 42
15/04/2013 16:46:08
Excludibility
Excludibility trip Pre-allarm
Trip curve
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
yes
yes
t=k
●
●
●
●
yes
●
●
●
●
yes
●
●
●
●
90% I4
yes
yes
90% I4
t = k / I2
●
●
●
●
yes
yes
90% I4
t=k
●
●
●
●
●
●
●
●
●
●
●
●
yes
yes
yes
90% I4
t = k / I2
yes
yes
no
t=k
●
●
yes
●
●
yes
●
●
yes
yes
no
t=k
●
●
●
●
Attivabile with rating
plug Rc
no
no
t=k
●
●
●
●
yes
yes
no
t=k
●
●
●
yes
yes
no
t=k
●
yes
yes
no
t=k
●
yes
yes
no
t=k
●
yes
yes
no
t=k
yes
yes
no
t=k
yes
yes
no
yes
yes
yes
yes
3
●
●
●
●
●
●
●
●
●
t=k
●
●
●
no
t=k
●
no
t=k
●
●
●
●
Table continued on next page
ABB catalogue | 1SDC200023D0201 | 3/43
Emax2_cap03.indd 43
15/04/2013 16:46:09
Technical characteristics for protection trip units
Protection functions
ABB Code
ANSI Code
Function
Thereshold
Threshold step
Tripping time
Time Step
OF2
81H
Overfrequency protection
f18= 1.01….1.1 x fn
0.01 x fn
t18 = 0.5…60s
0.1s
Tolerance
± 5%
Rate of change of frequency protection
f28= 0.4….10 Hz/s
Tolerance
± 10%
3
ROCOF
RP
RQ
81R
32R
40/32R
Reverse active power protection
P11= -1…-0.08 Sn
Tolerance
± 10%
Loss of field or reverse reactive power protection Q24= -1…-0.1 Sn
Kq= -2…2
Loss of field or reverse reactive power protection Q25= -1…-0.1 Sn
Kq2= -2…2
OP
OQ
UP
32OF
32OF
32LF
Tolerance
± 10%
Active overpower protection
P26= 0.4…2 Sn
Tolerance
± 10%
Reactive overpower protection
Q27= 0.4…2 Sn
Tolerance
± 10%
Active underpower protection
P23 = 0.1...1 x In
The better of the two data:
± 10% or ± 40 ms
0.2 Hz/s
The better of the two data:
± 10% or ± 40 ms
0.001 Sn
Synchrocheck 25
SC
± 10%
Synchrocheck (Live busbars)
Ulive= 0.5…1.1 Un
'U= 0.02…0.12 Un
'f= 0.1…1Hz
')= 5…50° elt
tsyn= 0.1…3s
Tolerance
± 10%
Synchrocheck (Live,Dead busbars)
Ulive= 0.5…1.1 Un
Udead= 0.02…0.2 Un
t11 = 0.5…100s
0.1s
The better of the two data:
± 10% or ± 40 ms
0.001 Sn
t24 = 0.5…100s
0.1s
t24 = 0.5…100s
0.1s
0.01
0.001 Sn
0.01
The better of the two data:
± 10% or ± 40 ms
0.001 Sn
t26 = 0.5…100s
0.5s
The better of the two data:
± 10% or ± 40 ms
0.001 Sn
t27 = 0.5…100s
0.5s
The better of the two data:
± 10% or ± 40 ms
0.001 x Sn
Temporary deactivation
Tolerance
with f > f28
0.1s
t28 = 0.4...10s with f28=0.4...1.0 Hz/s
t28 = 0.25...10s with f28=1.2...5.0 Hz/s
t28 = 0.15...10s with f28> 5.2 Hz/s
t23 = 0.5…100s
0.5s
range from closing: 0.1…30s
o with digital input
0.1s
The better of the two data:
± 10% or ± 40 ms
0.01 Un
0.01 Un
0.1Hz
5° elt
0.1s
tref= 0.1…30s
0.1s
0.01 Un
0.01 Un
tref= 0.1…30s
0.1s
Tolerance
± 10%
47
Cyclical direction of the phases
1-2-3 or 3-2-1
78
3phase Power factor
PF3= 0.2…0,95
0.01
Current thereshold
LC1=50%...100% I1
LC2=50%...100% I1
Iw= 0.3…10 In
1%
1%
0.01 x In
Tolerance
± 10%
1) G protection below 100A or 0.2 x In available with auxiliary supply.
The tollerances above apply to trip units already powered by the main circuit with current flowing in at least two-phases or an auxiliary power supply.
In all other cases the following tollerance values apply:
ABB Code
Trip threshold
L
Trip between 1.05 and 1.2 x I1
Trip time
± 20%
S
± 10%
± 20%
I
± 15%
d 60ms
G
± 15%
± 20%
Other protection
± 15%
± 20%
3/44 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 44
15/04/2013 16:46:10
Excludibility
Excludibility trip Pre-allarm
Trip curve
yes
yes
no
t=k
yes
yes
no
t=k
yes
yes
no
t=k
yes
yes
no
t=k
yes
yes
no
t=k
yes
yes
no
t=k
●
●
yes
yes
no
t=k
●
●
yes
yes
no
t=k
●
●
yes
only signalling
no
-
yes
only signalling
no
-
yes
only signalling
no
-
●
●
●
yes
only signalling
no
-
●
●
●
yes
only signalling
no
-
●
●
●
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
●
Ekip G Hi-Touch
●
3
●
●
●
●
●
●
●
●
yes
●
Key:
not available
available
available with Ekip Measuring Pro
available with Ekip Synchrocheck
ABB catalogue | 1SDC200023D0201 | 3/45
Emax2_cap03.indd 45
15/04/2013 16:46:11
Technical characteristics for protection trip units
Measurement functions
Instantaneous measurements
3
Displayed with
Ekip Multimeter
Parameters
Currents (RMS)
[A]
•
I1, I2, I3, neutral
Earth fault current (RMS)
[A]
•
Ig
[A]
•
I1, I2, I3, neutral
•
eg. L, S, I, G
Parameters
Record of values: of the parameter for each interval with time-stamping
Current: minimum and maximum
Parameters
Information on trip and opening data: after a fault with or without auxiliary supply
Type of protection tripped
Fault values per phase
[A]
Time-stamping
•
eg. I1, I2, I3, neutral for S protection
•
Date, time and progressive number
Maintenance indicators
Parameters
Information on last 30 trips
•
Type of protection, fault values and time-stamping
Information on last 200 events
•
Type of event, time-stamping
Can be associated to alarm
Number of mechanical operations (1)
[no]
•
Total number of trips
[no]
•
Total operating time
[h]
•
Wear of contacts
[%]
•
Prealarm >80%, Alarm = 100%
Date of maintenance operations performed
•
Last
Indication of maintenance operation needed
•
Circuit-breaker I.D.
•
Self-diagnosis
Type of circuit-breaker, assigned device name,
serial number
Parameters
Check of continuity of internal connnections
•
Alarm due to disconnection: rating plug, sensors,
trip coil
Failure of circuit-breaker to open (ANSI 50BF)
•
Alarm following non-tripping of protection functions
Temperature (OT)
•
Pre-alarm and alarm for abnormal temperature
(1)
with auxiliary supply present
3/46 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 46
15/04/2013 16:46:11
Precision
Standard di riferimento
1%
Class 1 IEC 61557-12
Ekip Dip
3
2%
Window
Intervals
Fixed, synchronizable by remote
Duration: 5…120min
Number of intervals: 24
Note: Opening of circuit-breaker
can be set in the event of alarm
ABB catalogue | 1SDC200023D0201 | 3/47
Emax2_cap03.indd 47
15/04/2013 16:46:11
Technical characteristics for protection trip units
Measurement functions
Instantaneous measurements
3
Parameters
Currents (RMS)
[A]
I1, I2, I3, neutral
Earth fault current (RMS)
[A]
Ig
Phase-phase voltage (RMS)
[V]
V12, V23, V31
Phase-neutral voltage (RMS)
[V]
V1n, V2n, V3n
Frequency
[Hz]
f
Active power
[kW]
P1, P2, P3, Ptot
Reactive power
[kVAR]
Q1, Q2, Q3, Qtot
Apparent power
[KVA]
S1, S2, S3, Stot
Phase sequence
Power factor
PF1, PF2, PF3, PF total
Peak factor
total
Parameters
Counters recorded from installation or from the last reset
Active energy
[kWh]
Ep total, Ep absorbed, Ep consumed
Reactive energy
[kVARh]
Eq total, Ep absorbed, Ep consumed
Apparent energy
[KVAh]
Es total
Network Analyzer
Parameters
Hourly average voltage value
[V]
[no]
- Umin= 0.75…0.95 x Un
- Umax= 1.05…1.25 x Un
- Events counter (nr. of events day by day in the last year plus the total
events in the breaker's lifetime)
Short voltage interruptions
[no]
- Umin= 0.75…0.95 x Un
- Events counter (nr. of events day by day in the last year plus the total
events in the breaker's lifetime)
Short voltage spikes
[no]
- Umax= 1,05…1,25 x Un
- Events counter (nr. of events day by day in the last year plus the total
events in the breaker's lifetime)
Slow voltage sags and swells
[no]
- Umin1= 0.75…0.95 x Un
- Umin2= 0.75…0.95 x Un
- Umin3= 0.75…0.95 x Un
- Umax1= 1.05…1.25 x Un
- Umax2= 1.05…1.25 x Un
- Events counter (nr. of events day by day in the last year plus the total
events in the breaker's lifetime)
Voltage unbalance
[V]
[no]
- U neg. seq.= 0.02…0.10 x Un
- Events counter (nr. of events day by day in the last year plus the total
events in the breaker's lifetime)
Harmonic analysis
Current and Voltage
- up to 50°
- Alarm THD: 5…20%
- Single harmonic alarm:
3...10% plus a count of minutes the harmonic has been exceeded
3/48 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 48
15/04/2013 16:46:11
Precision
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
1%
2%
3
0.5%
0.5%
0.2%
2%
2%
2%
2%
Precision
2%
2%
2%
Intervals
t = 5…120min
-
-
t <40ms
-
-
t <40ms
-
-
t = 0.04ms...60s
-
-
t = 5…120min
-
-
-
-
ABB catalogue | 1SDC200023D0201 | 3/49
Emax2_cap03.indd 49
15/04/2013 16:46:12
Technical characteristics for protection trip units
Measurement functions
Parameters
Record of values: of the parameter for each interval with time-stamping
3
Current: minimum and maximum
[A]
I1, I2, I3, neutral
Phase-phase voltage: minimum and maximum
[V]
V12, V23, V31
Active power: average and maximum
[kW]
Ptot
Reactive power: average and maximum
[kVAR]
Qtot
Apparent power: average and maximum
[KVA]
Stot
Parameters
Data logger: record of high sampling rate parameters
Currents
[A]
Voltages
[V]
I1, I2, I3, neutral, Ig
U12, U23, U31
Sampling rate
[Hz]
1200-9600
Maximum recording duration
[s]
18
Recording stop delay
[s]
0-10s
Number of registers
[no]
2 independent
Information on trip and opening data: after a fault without auxiliary supply
Parameters
Type of protection tripped
eg. L, S, I, G, UV, OV
Fault values per phase
[A/V/Hz w/VAR]
eg. I1, I2, I3, neutral for S protection
V12, V23, V32 for UV protection
Time-stamping
Date, time and progressive number
Maintenance indicators
Parameters
Information on last 30 trips
Type of protection, fault values and time-stamping
Type of event, time-stamping
Information on last 200 events
Number of mechanical operations (1)
[no]
Total number of trips
[no]
Total operating time
[h]
Wear of contacts
[%]
Date of maintenance operations performed
Can be associated to alarm
Prealarm >80%
Alarm = 100%
Last
Indication of maintenance operation needed
Circuit-breaker I.D.
Type of circuit-breaker, assigned device name, serial number
Self-diagnosis
Parameters
Check of continuity of internal connnections
Alarm due to disconnection: rating plug, sensors, trip coil
Failure of circuit-breaker to open (ANSI 50BF)
Alarm following non-tripping of protection functions
Temperature (OT)
Prealarm and alarm for abnormal temperature
(1) with auxiliary supply present
3/50 | 1SDC200023D0201 | ABB catalogue
Emax2_cap03.indd 50
15/04/2013 16:46:12
Window
Intervals
Fixed
synchronizable by remote
Duration: 5…120min
Number of intervals: 24
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
3
Note: Opening of circuit-breaker
can be set in the event of alarm
Key:
not available
available
available with Ekip Measuring Pro
ABB catalogue | 1SDC200023D0201 | 3/51
Emax2_cap03.indd 51
15/04/2013 16:46:13
Emax2_cap03.indd 52
15/04/2013 16:46:13
Communication devices and systems
Introduction
4/2
Supervision and control
Supervision of the switchgear compartment
4/4
Supervision of the electrical switchgear
4/6
Supervision of the electrical installation
4/8
Software
Ekip Connect
4/10
Ekip View
4/12
Ekip T&P Interface
4/14
4
ABB Catalogue | 1SDC200023D0201 | 4/1
Emax2_cap04.indd 1
12/04/2013 13:58:12
Communication devices and systems
Introduction
SACE Emax 2 circuit-breakers provide a complete and flexible offering that can be
adapted to the actual level of supervision and control required.
The rapid spread of systems for the supervision and control of low voltage electrical distribution plants is determined by the
growing need to:
- optimize energy efficiency by analyzing energy consumption;
- ensure service continuity, minimizing the time needed to identify and rectify faults;
- guarantee efficient planning of maintenance activities.
4
Typical sector
Industrial
Hospital
Level of supervision and control
in low voltage systems
Switchgear compartment
Sulution with SACE Emax 2
- Ekip Touch trip units with high
resolution display
OEMs
Naval
- Ekip trip units
- Ekip Multimeter display on the
front of switchgear
Benefit of the ABB solution
- simple and intuitive use
- reduced dimensions
- does not require an auxiliary
power supply for safety
- flexible installation
- simultaneous reading of various
electrical values
4/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 2
12/04/2013 13:58:13
According to their complexity, the supervision of low voltage systems may involve different levels:
- switchgear compartment: for the control of the main electrical values of the circuit-breaker. It provides a general but precise
indication of the level of absorption of the system (main circuit-breaker) and the individual utilities (outgoing feeder circuit-breakers).
- electrical switchgear: to display the data of all circuit-breakers installed in the switchgear from a single point: in local mode
via the operator panel on the front of the switchgear, or remotely via an Internet connection.
- electrical system: to manage complex systems in which devices must be integrated with automated industrial processes or
in intelligent electrical networks, better known as smart grids.
4
Industries
of medium
dimensions
Shopping
centres
Office buildings Oil & gas
Automated
industrial
processes
Data centers
Electrical switchgear
Electrical installation
- Ekip trip units
- Ekip Touch trip units
- Ekip link modules
- Ekip com communication modules
- Ekip Control Panel operator panel
colour touch screen
- Ekip View supervision software
Smart grids
- Standardized EtherNet components
- centralized control from front of switchgear
- wide range of protocols supported
- access via web to the installation
- installation times reduced to a minimum
- rapid installation
- redundancy of communication
- ease of use
- ready to smart grid circuit-breakers
- system ready to use
- complete network supervision
ABB Catalogue | 1SDC200023D0201 | 4/3
Emax2_cap04.indd 3
12/04/2013 13:58:14
Communication devices and systems
Supervision of the switchgear compartment
The SACE Emax 2 circuit-breakers equipped with Ekip electronic trip units enable
electrical measurements and diagnostic data to be displayed on the front of the
switchgear.
Ekip Multimeter
1SDC200491F001
Ekip Touch
1SDC200492F001
4
Solution with Ekip Touch trip units
The Ekip Touch electronic trip units are, therefore, the ideal solution for supervision and control of the compartments in
switchgear. In particular:
- their use is simple and intuitive thanks to a large, high resolution, colour touch screen;
- they do not require an auxiliary power supply for safety; the Ekip Touch trip units are directly supplied by the current sensors
integrated in the circuit-breaker, thereby avoiding the use of external power supplies.
For the list of information available for each trip unit, consult chapter 3.
4/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 4
12/04/2013 13:58:15
Solution with Ekip Multimeter Display on switchgear front
The Ekip Multimeter is a display unit to be installed on the front of the switchgear for SACE Emax 2 air circuit-breakers
equipped with Ekip electronic trip units.
This device remotely displays the information about the system that is available in the trip unit to which it is connected.
The main characteristics of the Ekip Multimeter unit are:
- Graphical and functional uniformity with the Ekip Touch trip units; Ekip Multimeter uses the same display as the trip unit to
which it is connected, ensuring perfect continuity between the graphic display and the menu items.
- Reduced dimensions; the Ekip Multimeter guarantees the precision of the trip unit to which it is connected and performs the
function of a measuring instrument without requiring the installation of external current and voltage transformers.
- Flexible installation; the Ekip Multimeter can be installed up to distance from the trip unit, enabling access to information from
the most convenient point.
- Simultaneous reading of the various electrical values; the advanced connection system used allows several Ekip Multimeter
devices to be connected to the same protection trip unit.
Furthermore, if connected to trip units equipped with display, the Ekip Multimeter enables adjustment of the parameters and
protection thresholds.
4
Supervision of switchgear compartment
Electronic trip unit
Ekip Dip
Ekip Touch
Solution
Ekip trip units + Ekip Multimeter
Type of trip units connectable to Ekip Multimeter
Ekip trip units
Number of trip units connectable to Ekip Multimeter
1
Ekip Touch + Ekip
measuring module
Ekip Hi Touch
Ekip G Touch
Ekip Hi-G Touch
Measurement functions
Currents
•
•
•
•
Voltages
-
-
•
•
Powers
-
-
•
•
Energies
-
-
•
•
Harmonics
-
-
-
•
Network analyzer
-
-
-
•
Setting of thresholds
-
•
•
•
Setting of thresholds sacond set
-
-
-
•
Resetting of alarms
•
•
•
•
Protection function alarms
•
•
•
•
Device alarms
•
•
•
•
Protection unit tripping details
•
•
•
•
Events log
•
•
•
•
Protection unit tripping log
•
•
•
•
Number of operations
•
•
•
•
Number of trips
•
•
•
•
Wear of contacts
•
•
•
•
Adjustment functions
Diagnostics
Maintenance
Other data
Status of circuit-breaker
Circuit-breaker position
1)
Local/remote mode
•
•
•
•
•
•
•
•
•
•
•
•
1) Circuit-breakers equipped with auxiliary contacts to indicate position
ABB Catalogue | 1SDC200023D0201 | 4/5
Emax2_cap04.indd 5
12/04/2013 13:58:15
Communication devices and systems
Supervision of the electrical switchgear
Ekip Link is a flexible and efficient solution for controlling and supervising low
voltage electrical switchgear; it is a system that enables SACE Emax 2 circuitbreakers to be connected to the Ekip Control Panel operator panel by means of
Ekip Link interface modules.
4
Ekip Link system
The main characteristics of the Ekip Link System are:
- centralized control; from the Ekip Control Panel operator panel, all the main values of the installation (electrical
measurements, system diagnostics, trends…) can be displayed, and all circuit-breakers connected directly to the front of the
switchgear can be inspected.
- adaptation to real requirements; when the electrical values to be monitored are limited to currents only, the Ekip Dip trip
unit can be connected to the Ekip Link without having to use circuit-breakers equipped with communication modules.
- access via the Internet to the installation by any Internet browser using the web server function performed by the Ekip
Control Panel.
- rapid installation, through the use of standardized EtherNet components such as STP cables and RJ45 type connectors.
- ease of use; thanks to the Ekip Control Panel operator panel in front of the switchgear with colour touch screen, the system
mimic panel can be displayed so that the entire installation can be controlled rapidly and intuitively.
- ready to use; Ekip Control Panel is supplied with pre-configured software that requires no programming. It is only necessary
to start scanning the Ekip Link system from the operator panel and in a few seconds communication with the connected
devices is active.
1SDC200493F001
Ekip Link enables supervision of electrical switchgear on which up to 30 ABB SACE circuit-breakers have been installed.
Tmax T and Tmax XT series circuit-breakers equipped with Modbus RTU communication can also be easily integrated into the
Ekip Link system using the multi-serial port fitted on the Ekip Control Panel.
4/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 6
12/04/2013 13:58:17
Supervision of switchgear compartment
Electronic trip unit
Ekip Dip
Ekip Touch
Ekip Touch + Ekip
measuring module
Ekip Hi Touch
Solution
Ekip protection trip units equipped with Ekip link module
+ Ekip Control Panel operator panel + standard EtherNet components
Ekip G Touch
Ekip Hi-G Touch
Type of trip units connectable
Ekip protection trip units
Number of trip units connectable to the Ekip link system
up to 30
Data exchange rate of Ekip link system
100 Mbit/sec
1)
Supervision and control functions
Opening and Closing of circuit-breakers
2)
4
•
Electrical value trends
I
I
I,V,P
I,V,P
Log of electrical value trends
I
I
I,V,P
I,V,P
Dynamic installation mimic panel
•
Automatic scanning of the Ekip link system
•
Centralized synchronizing of time
•
Web server function
•
3)
Measurement functions
Currents
•
•
•
•
Voltages
-
-
•
•
Powers
-
-
•
•
Energies
-
-
•
•
Harmonics
-
-
-
•
Network analyzer
-
-
-
•
Data logger
-
•
•
•
Setting of thresholds
-
•
•
•
Resetting of alarms
•
•
•
•
Adjustment functions
Diagnostics
Protection function alarms
•
Device alarms
•
Protection unit tripping details
•
Events log
•
Protection unit tripping log
•
Transmission of alarms via SMS
optional
Transmission of alarms via e-mail
optional
Maintenance
Number of operations
•
Number of trips
•
Wear of contacts
•
Other data
Status of circuit-breaker
Circuit-breaker position
Local/remote mode
•
4)
•
•
1) Ekip Control Panel is available in two versions that can manage a maximum of 10 or 30 circuit-breakers. The number of circuit-breakers may vary depending on their type.
For details, ask ABB SACE
2) Circuit-breakers equipped with actuation module, electric accessories, opening and closing releases and spring charging motor
3) Two client web accesses included in the licence
4) Circuit-breakers equipped with auxiliary contacts to indicate position
ABB Catalogue | 1SDC200023D0201 | 4/7
Emax2_cap04.indd 7
12/04/2013 13:58:17
Communication devices and systems
Supervision of the electrical installation
The integration of low voltage devices in communication networks is required in
particular for: automated industrial processes, industrial and petrochemical sites,
modern data centres and intelligent electricity networks, better known as smart grids.
Ekip Com Modules
Thanks to the wide range of communication protocols supported, SACE Emax 2 circuit-breakers equipped with Ekip Touch
electronic trip units can be integrated into communication networks without the need for external interface devices.
The distinctive characteristics of the SACE Emax 2 circuit-breakers offering for industrial communication are:
- Wide range of protocols supported; the Ekip Com communication modules enable integration with the most common
communication protocols based on RS485 serial lines and the most modern communication systems based on EtherNet
infrastructures, which guarantee an exchange of data in the order of 100 Mbit/s.
- Installation times reduced to a minimum due to the plug & play technology of the communication modules, which are
connected directly to the circuit-breaker terminal box without having to remove the electronic trip unit.
- Repetition of communication for greater reliability of the system; the circuit-breaker can be equipped with two
communication modules at the same time, allowing the information on two buses to be exchanged simultaneously.
- Ready to smart grid; the Ekip Com 61850 module is the solution for integrating SACE Emax 2 circuit-breakers into the
automated systems of electrical substations based on the IEC 61850 standard without the need for complex external devices.
- Complete supervision of Modbus RTU or Modbus TCP/IP networks via the software for PC Ekip View.
1SDC200494F001
4
4/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 8
12/04/2013 13:58:18
Supervision of switchgear compartment
Electronic trip unit
Ekip Touch
Ekip Touch + Ekip
measuring module
Ekip Hi Touch
Solution
Ekip Touch trip units + Ekip com modules
Ekip G Touch
Ekip Hi-G Touch
Protocols supported:
Modbus RTU
Ekip com Modbus
Profibus-DP
Ekip com Profibus
DeviceNet
Ekip com DeviceNet
Modbus TCP/IP
Ekip com Modbus TCP
Profinet
Ekip com Profinet
EtherNet IP
Ekip com EtherNet
IEC61850
Ekip com IEC61850
4
Control functions
Circuit-breakers opening and closing
1)
•
•
•
Measurement functions
Currents
•
•
•
Voltages
-
•
•
Powers
-
•
•
Energies
-
•
•
Harmonics
-
-
•
Network analyzer
-
-
•
Data logger
•
•
•
Setting of thresholds
•
•
•
Resetting of alarms
•
•
•
Adjustment functions
Diagnostic
Protection function alarms
•
Device alarms
•
Protection unit tripping details
•
Events log
•
Protection unit tripping log
•
Maintenance
Number of operations
•
Number of trips
•
Wear of contacts
•
Other data
•
Status of circuit-breaker
Circuit-breaker position
Local/remote mode
2)
•
•
1) Circuit-breakers equipped with Ekip Com Actuator module, electrical accessories, opening and closing releases and spring charging motor
2) Circuit-breakers equipped with auxiliary contacts to indicate position
ABB Catalogue | 1SDC200023D0201 | 4/9
Emax2_cap04.indd 9
12/04/2013 13:58:18
Communication devices and systems
Supervision and control software
ABB SACE offers software applications that allow the potential of the Ekip
electronic trip units to be utilized in the best possible way in terms of the
management of power, acquisition and analysis of the electrical values,
and testing of the protection, maintenance and diagnostic functions.
Overview of the software
An overview of the software available and their main characteristics are given below:
4
Software
Functions
Distinctive characteristics
Ekip Connect
- commissioning of circuit-breakers
- analysis of faults
- testing of communication bus
- simple and intuitive use
- integrated with DOC electrical design software
- useable via EtherNet
- automatic updating from Internet
- off-line mode
- multi-media (smart phone, tablet or PC)
Ekip View
- supervision and control of communication networks
- analysis of electrical value trends
- condition monitoring
- engineering free
- analysis of past trends
- customizable reports
- access via Internet to the installation
- possibility of integrating third party devices
Ekip T&P interface
- testing of protection functions
- ordinary maintenance of trip units
- test signals can be pre-set or configured as desired
- advanced graphical interface
- generation of test reports
1SDC200495F001
Ekip Connect
Ekip Connect enables data to be exchanged with one or more protection trip units, which:
- Assists commissioning of the system; all system parameters and the protection thresholds can be set rapidly in the Ekip
trip units thanks to the easy and intuitive navigation pages of the software.
- Permits rapid access to diagnostics; it is possible to consult and download the records of events, alarms and the tripping
of the trip units, thereby facilitating the identification and understanding of the anomalies.
4/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 10
12/04/2013 13:58:18
- Enables testing of the communication network; Ekip Connect performs an automatic scan of the Modbus RS-485 or
Modbus TCP network and determines whether the circuit-breakers have been correctly connected and, when necessary,
signals incorrect configurations of the communication parameters (addresses, baud rate, parity).
The distinctive characteristics of the software are:
- Integration with DOC electrical design software; the adjustments and settings calculated by the DOC software can be
downloaded directly into the protection trip units, thereby reducing commissioning times and the probability of errors.
- Ease of connection: the Ekip trip units equipped with Modbus TCP Ekip com modules can be controlled directly by the
EtherNet network.
- Multi-media; Ekip Connect is designed to operate on a PC or on the more modern tablet PCs and smart phones.
- Automatic updating from the Internet site; if connected to an Internet site, the software is able to constantly control the
availability of any updates.
4
The software is available free of charge on the ABB website www.abb.com/lowvoltage.
Media
Ekip Connect Software
Personal PC
Smartphone/Tablet iPhone/iPad
Operating system
Windows XP, Windows 7, Windows Vista
Android
iOS
Method of connection to the trip units
Communication
network
Test connector
Wireless
communication
Wireless
communication
Wireless
communication
SACE Emax 2 trip units
Ekip com Modbus
RS485 or TCP
Ekip T&P
Ekip Bluetooth
Ekip Bluetooth
Ekip Bluetooth
SACE Tmax XT trip units
Ekip com
Ekip T&P
Ekip Bluetooth
-
-
SACE Emax,T7,X1,T8 trip units
PR120/D-M,
PR330/D-M
Ekip T&P or BT030
BT030
-
-
SACE Tmax T trip units
PR222DS/PD,
Ekip T&P or BT030
PR223DS; PR223/EF
BT030
-
-
Automatic network scan
•
-
-
-
-
Opening and closing of circuit-breakers1)
•
•
•
•
•
Setting of thresholds
•
•
•
•
•
Resetting of alarms
•
•
•
•
•
Reading of electrical measurements
•
•
•
•
•
Displaying of time-current curve
•
•
•
•
•
Reading of past records
•
•
•
•
•
DataLogger download
•
•
•
-
-
Generating of Reports
•
•
•
•
•
Automatic updating from Internet
•
•
•
•
•
Integration with DOC
•
•
•
•
•
Enabling of Ekip T&P Interface
•
•
•
•
•
Use via EtherNet
•2)
-
-
-
-
Functions of reading and control
Other functions
1) Circuit-breakers equipped with auxiliary contacts to indicate position
2) only in the presence of Modbus TCP Ekip Com modules
ABB Catalogue | 1SDC200023D0201 | 4/11
Emax2_cap04.indd 11
12/04/2013 13:58:18
Communication devices and systems
Supervision and control software
Ekip View
Ekip View is the software for supervising devices connected to a communication network that uses the Modbus RTU or
Modbus TCP protocol.
4
It
-
is the ideal tool for all applications that require:
remote control of the system,
monitoring of power consumption,
fault detection of the system,
allocation of energy consumption to the different processes and departments,
preventative planning of maintenance.
1SDC200496F001
The main characteristics of Ekip View are:
- Engineering free and ready to use software which guides the user in the recognition and configuration of the protection
units without the need for any supervision system engineering activities.
- Dynamic mimic panel; after automatic scanning of the network, for each of the devices found, Ekip View proposes a
dynamic symbol that summarizes the most important information (status, electrical measurements, alarms). The extensive
library of electrical symbols enables the entire electrical system to be depicted in detail.
- Analysis of trends; the instantaneous and past trends of currents, powers and power factors are represented graphically
and can be exported into Microsoft Excel for detailed analysis.
- Reports; advanced reports can be created regarding system and communication network diagnostics. Using the Alarm
Dispatcher option, the user can receive the most important indications via SMS or e-mail.
- Access via web to the installation, thanks to the Web Server function of Ekip View.
4/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 12
12/04/2013 13:58:18
Ekip View Software
Communication characteristics
Protocol Supported
Modbus RTU
Modbus TCP
Physical layer
RS 485
EtherNet
Maximum data exchange rate
19200 bps
100 Mbps
Operating system
Windows XP, Windows 7, Windows Vista
Devices supported
SACE Emax 2 trip units
Ekip com Modbus RS485
Ekip com Modbus TCP
SACE Emax,T7,X1,T8 trip units
PR120/D-M, PR330/D-M
-
SACE Tmax T trip units
PR222DS/PD, PR223DS
-
SACE Tmax XT trip units
Ekip com
-
Third party devices
optional
Licences available
4
1)
- up to 30
2)
controllable devices
- up to 60
2)
controllable devices
- unlimited number
3)
controllable devices
Supervision and control functions
Opening and Closing of circuit-breakers
4)
•
Electrical value trends
•
Log of electrical value trends
•
Dynamic installation mimic panel
•
Automatic scanning
•
Centralized synchronizing of time
•
5)
Web server function
•
Redundancy
optional
OPC server-client
optional
Measurement functions
6)
Currents
•
Voltages
•
Powers
•
Energies
•
Harmonics
•
Network analyzer
•
Data logger
•
Adjustment functions
Setting of thresholds
•
Resetting of alarms
•
Diagnostics
Protection function alarms
•
Device alarms
•
Communication system alarms
•
Protection unit tripping details
•
Events log
•
Protection unit tripping log
•
Generation of Reports
•
Transmission of alarms via SMS
optional
Transmission of alarms via e-mail
optional
Maintenance
Number of operations
•
Number of trips
•
Wear of contacts
•
Other data
Status of circuit-breaker
Circuit-breaker position
local/remote mode
•
7)
•
•
1) Contact ABB SACE to integrate other devices in the Ekip View software
2) can be increased
3) within the physical limit of the protocol used
4) circuit-breakers equipped with Ekip com Actuator module and electrical accessories
5) two client web accesses included in the licence, optional up to 5 accesses
6) according to the values supported by the trip units
7) circuit-breakers equipped with auxiliary contacts for position indication
ABB Catalogue | 1SDC200023D0201 | 4/13
Emax2_cap04.indd 13
12/04/2013 13:58:18
Communication devices and systems
Supervision and control software
Ekip T&P Interface
The Ekip T&P Interface software, used together with the Ekip T&P device, enables the electronic protection trip units to be
tested for correct operation during the stages of commissioning and system maintenance.
Thanks to advanced graphical interfaces, the user can simply select the test to perform: from simple current and voltage
signals to more complex wave forms with the presence of harmonic distortion.
1SDC200497F001
4
4/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap04.indd 14
12/04/2013 13:58:19
The software creates and stores all reports, keeping a record of the tests carried out and essential information such as the
operator name, date, serial number of the circuit-breaker, type of test and the result.
1SDC200498F001
4
ABB Catalogue | 1SDC200023D0201 | 4/15
Emax2_cap04.indd 15
12/04/2013 13:58:19
Emax2_cap04.indd 16
12/04/2013 13:58:19
Accessories
Functional areas
5/2
Standard supply
5/4
Accessories for circuit-breakers
5/6
Signalling
5/7
Control
5/10
Safety
5/15
Protection devices
5/16
Connections
5/18
Interlocks and switching devices
5/20
Accessories for Ekip trip units
5/23
Power supply
5/25
Connectivity
5/25
Signalling
5/27
Measurements and protection
5/28
Displaying and supervision
5/32
Testing and programming
5/33
Spare parts
5/34
5
ABB Catalogue | 1SDC200023D0201 | 5/1
Emax2_cap05.indd 1
15/04/2013 16:51:41
Accessories
Functional areas
The new SACE Emax 2 circuit-breakers have been designed to optimize the
installation and commissioning of accessories.
The front of the circuit-breaker features two functional areas, which are protected by separate covers:
- Accessories area for the installation of accessories inside the circuit-breaker and Ekip trip unit. The areas dedicated to
accessories can be accessed by removing the flange and the accessories covers. On removal, the operating mechanism area
remains segregated and protected, providing safety for operators.
- Safety area, which delimits the housing of the stored energy operating mechanism of the circuit-breaker. To carry out
maintenance on the operating mechanism, the covers of the accessories and safety area must be removed.
5
2
1
1SDC200499F001
1
5/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 2
15/04/2013 16:51:42
As a result of distinct functional areas that determine the operating spaces, the
accessorizing logic of the circuit-breakers has been considerably simplified.
The auxiliary connection terminal box also features two areas:
- Terminals area for housing and inserting the terminals for wiring the auxiliary connections. The terminals can be wired first
and then installed on the circuit-breaker terminal box, thereby facilitating cable connection for the operator.
- Cartridge modules area, housing for the Ekip modules. These are installed directly from the upper part of the circuit-breaker
or of the fixed part without having to remove the Ekip electronic trip unit, thereby minimizing the time required for introducing
and commissioning the accessories.
5
3
4
1SDC200500F001
3
1
2
3
4
accessories area
safety area
terminals area
cartridge modules area
ABB Catalogue | 1SDC200023D0201 | 5/3
Emax2_cap05.indd 3
15/04/2013 16:51:42
Accessories
Standard supply
The fixed versions of SACE Emax 2 automatic circuit-breakers and switch-disconnectors are always supplied as standard with
the following accessories:
- IP30 protection for switchgear door
- lifting plates for E2.2 … E6.2 circuit-breaker
- front terminals for E1.2 circuit-breaker
- adjustable rear terminals for E2.2 … E6.2 circuit-breaker, mounted in HR – HR configuration
- screws for securing in the switchgear
1SDC200501F001
5
In addition, for fixed automatic circuit-breakers only:
- four standard open/closed auxiliary contacts - AUX 4Q
- four terminals for auxiliary connections
- mechanical signalling of the tripping of the protection trip unit - TU Reset
- Ekip TT power supply and test unit, when a protection trip unit is present with display
- contact signalling tripping of Ekip protection trip unit S51.
5/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 4
15/04/2013 16:51:42
The withdrawable versions of automatic circuit-breakers and switch-disconnectors are always supplied as standard with the
following accessories:
- closed circuit-breaker racked-out mechanism lock
- lifting plates for E2.2 ... E2.6 circuit-breakers
- lever for racking in and racking out
- anti-insertion lock
In addition, for withdrawable automatic circuit-breakers only:
- four standard open/closed auxiliary contacts - AUX 4Q
- four terminals for auxiliary connections
- mechanical signalling of the tripping of the protection trip unit - TU Reset
- Ekip TT power supply and test unit, when a protection trip unit is present with display.
5
1SDC200502F001
The fixed parts feature:
- IP30 protection for switchgear door
- anti-insertion lock
- standard shutter lock – SL
- screws for securing to the floor
- adjustable rear terminals, mounted in HR – HR configuration
ABB Catalogue | 1SDC200023D0201 | 5/5
Emax2_cap05.indd 5
15/04/2013 16:51:43
Accessories
Accessories for circuit-breakers
SACE Emax 2 circuit-breakers offer a wide range of accessories developed to satisfy the application and installation
requirements of every customer.
Automatic
circuit-breaker
E1.2
E2.2 - E4.2
- E6.2
Switch-disconnector
E1.2
E2.2 - E4.2
- E6.2
Derived versions
CS
MT
MTP
E2.2 - E4.2 - E6.2
Signalling
Standard open/closed auxiliary contacts - AUX 4Q
/
Open/closed auxiliary contacts - AUX 6Q
-
Open/closed auxiliary contacts- AUX 15Q
/
/
-
/
/
/
/
/
/
-
-
-
/
-
-
-
/
-
-
-
Auxiliary position contacts - AUP
5
Ready to close signalling contact - RTC
/
/
-
-
-
TU Reset mechanical signalling of the tripping of protection trip unit - TU Reset
/
/
-
-
-
-
-
Contact signalling tripping of Ekip protection trip unit - S51
/
/
-
-
-
-
-
Contact signalling loaded springs – S33 M/2 (supplied with Motor)
/
/
/
/
-
-
-
Opening and closing release - YO/YC
/
/
/
/
-
-
-
Second opening and closing release - YO2/YC2
/
/
/
/
-
-
-
Undervoltage release - YU
/
/
/
/
-
-
-
Electronic time-delay device for undervoltage release - UVD
/
/
/
/
-
-
-
Motor - M
/
/
/
/
-
-
-
Remote reset - YR
/
/
-
/
Control
Opening and closing release test unit - YO/YC Test Unit
/
-
-
-
-
/
/
-
-
-
-
-
-
-
-
-
-
/
Safety
Key lock and padlock in open position - KLC and PLC
/
/
/
/
Key lock and padlock in racked-in / test / racked-out position - KLP and PLP
Shutter lock - SL
External shutter lock - SLE
-
-
Lock for racking-out mechanism with circuit-breaker in closed position
Lock for racking in / racking out the mobile part when the door is open - DLR
-
-
-
-
Lock to prevent door opening when circuit-breaker is in racked-in /
test position - DLP
-
-
-
-
Lock to prevent door opening when circuit-breaker is in closed position - DLC
/
/
/
/
-
-
Anti-insertion lock
/
/
/
/
-
-
Mechanical operation counter - MOC
/
/
/
/
-
-
Protection devices
Protection device for opening and closing pushbuttons - PBC
-
-
IP30 Protection
/
/
/
/
-
-
IP54 Protection
/
/
/
/
-
-
/
/
/
/
/
Terminal covers - HTC / LTC
/
-
-
-
-
-
-
Separators - PB
/
-
-
-
-
-
-
Orientable rear terminal - HR/VR
-
-
Front terminal - F
-
-
-
-
-
-
-
-
Connections
Other configurations
/
/
/
/
Interlocks and switching devices
Mechanical interlock - MI
Automatic transfer switches - ATS
/
/
/
/
/
/
/
/
/
/
/
/
Standard accessory for fixed circuit-breaker
Accessory on request for fixed circuit-breaker
Standard accessory for mobile part
Accessory on request for mobile part
Standard accessory for fixed part
Accessory on request for fixed part
5/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 6
15/04/2013 16:51:43
1SDC200503F001
Signalling
Open / closed auxiliary contacts - AUX
SACE Emax 2 circuit-breakers can be equipped with auxiliary contacts that signal the open or closed
status of the circuit-breaker. The first block of four standard contacts is always provided with the
automatic circuit-breakers. The switching contacts are available in the following configurations:
Open / closed auxiliary contacts (AUX 4Q)
E1.2
E2.2 … E6.2
4 auxiliary contacts
standard
•
•
digital signals
•
•
mixed
•
•
Open / closed supplementary auxiliary contacts (AUX 6Q)
1SDC200504F001
6 auxiliary contacts
standard
-
•
digital signals
-
•
mixed
-
•
5
Open / closed external supplementary auxiliary contacts (AUX 15Q)
15 auxiliary contacts
standard
•
•
digital signals
•
19
•
Maximum number of open / closed
auxiliary contacts that can be installed
25
Standard contact
Contact for digital signals
Type
changeover contacts
changeover contacts
Minimum load
100mA @ 24V
1mA @ 5V
Breaking capacity
1SDC200505F001
DC
AC
24V
-
0.1A
125V
0.3A @ 0ms
-
250V
0.15A @ 0ms
-
250V
5A @ cosM 1
-
5A @ cosM 0.7
-
400V
5A @ cosM 0.3
-
3A @ cosM 1
-
2A @ cosM 0.7
-
1A @ cosM 0.3
-
Electrical diagram reference: figure 1, 81, 91
AUX 6Q is an alternative to the Ekip Signalling 4K module. AUX 15Q is an alternative to the
mechanical interlock (MI) and the DLP and DLC locks.
ABB Catalogue | 1SDC200023D0201 | 5/7
Emax2_cap05.indd 7
15/04/2013 16:51:44
1SDC200506F001
Accessories
Accessories for circuit-breakers
Auxiliary position contacts - AUP
When the circuit-breaker is a withdrawable version, the position of the mobile part can be signalled
electrically by accessorizing the fixed part with one of the following signalling contact units:
Auxiliary position contacts (AUP)
E1.2
E2.2 … E6.2
standard
•
-
digital signals
•
-
standard
-
•
digital signals
-
•
standard
-
•
digital signals
-
•
Maximum number of auxiliary position
contacts that can be installed
6
10
Standard contact
Contact for digital signals
Type
changeover contacts
changeover contacts
Minimum load
100mA @ 24V
1mA @ 5V
6 auxiliary contacts
5 auxiliary contacts
5 supplementary
auxiliary contacts
1SDC200507F001
5
Breaking capacity
DC
AC
24V
-
0.1A
125V
0.3A @ 0ms
-
250V
0.15A @ 0ms
-
250V
5A @ cosM 1
-
5A @ cosM 0.7
-
5A @ cosM 0.3
-
3A @ cosM 1
-
2A @ cosM 0.7
-
1A @ cosM 0.3
-
400V
1SDC200508F001
Electrical diagram reference: figure 95, 96, 97
Ready to close signalling contact - RTC
The ready to close signalling contact – RTC – indicates that the circuit-breaker is ready to
receive the closing command. The circuit-breaker is ready to close in the following conditions:
- circuit-breaker open
- springs loaded
- no opening command or locks on the opening command
- circuit-breaker reset following tripping of Ekip protection trip unit.
Standard contact
Contact for digital signals
Type
Switching
Minimum load
100mA @ 24V
1mA @ 5V
24V
-
0.1
250V
0.5A @ 0ms / 0.2A 10ms
-
250V
3A @ cosM 0.7
-
Breaking capacity
DC
AC
Electrical diagram reference: figure 71
5/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 8
15/04/2013 16:51:45
1SDC200509F001
Mechanical signalling of the tripping of protection trip unit - TU Reset
The automatic circuit-breakers are always equipped with a mechanical device that signals
the tripping status of the protection trip units. After the Ekip trip unit has tripped due to an
electrical fault, the signalling device clearly indicates the tripping status on the front of the
circuit-breaker. The circuit-breaker can be reset only after the signalling pushbutton has been
restored to its normal operating position. The device conforms to the Ansi 86T standard.
Contact signalling tripping of protection trip unit Ekip – S51
The contact signals the opening of the circuit-breaker after the Ekip protection trip unit
has tripped. The circuit-breaker can only be closed after the “TU Reset” tripped trip unit
mechanical signalling pushbutton has been restored to its normal operating position.
The switching contact, which is always supplied with the standard version of the automatic
circuit-breakers, is also available on request in a version for digital signals (for electrical
characteristics, please refer to the RTC contact). It can also be associated to an optional
accessory for resetting by remote control - YR. For electromechanical characteristics, please
refer to the RTC contact.
5
Electrical diagram reference: figure 11
Contact signalling loaded springs – S33 M/2
This contact is always supplied with a geared motor; it remotely signals the spring status of
the circuit-breaker operating mechanism. It is available in both standard version and version
for digital signals.
Standard contact
Contact for digital signals
Type
changeover contacts
changeover contacts
Minimum load
100mA @ 24V
1mA @ 5V
-
0.1A
125V
0.3A @ 0ms
-
250V
0.15A @ 0ms
-
250V
5A @ cosM 1
-
5A @ cosM 0.7
-
5A @ cosM 0.3
-
3A @ cosM 1
-
2A @ cosM 0.7
-
1A @ cosM 0.3
-
Breaking capacity
DC
AC
24V
400V
Electrical diagram reference: figure 12
ABB Catalogue | 1SDC200023D0201 | 5/9
Emax2_cap05.indd 9
15/04/2013 16:51:45
Accessories
Accessories for circuit-breakers
1SDC200510F001
Control
Opening and closing release- YO/YC
The opening and closing releases enable the circuit-breaker to be controlled remotely. Opening
is always possible, while closing is available only when the closing springs of the operating
mechanism are loaded and the circuit-breakers is ready to close.
The releases operate by means of minimum impulse current duration time of 100 ms.
Furthermore, they can operate in permanent service. In this case, if opening command is
given by means of the opening release, the circuit-breaker can be closed by de-energizing the
opening release and, after a time of at least 30 ms, by controlling the closing.
Electrical diagram reference: figure 75, 77
Second opening and closing release - YO2/YC2
For certain installations the redundancy of mechanisms and circuit-breaker operating circuits is
often requested. To answer these needs, the SACE Emax 2 circuit-breakers can be equipped
with double opening release and double closing release. The technical characteristics of the
second opening release remain the same as those of the first opening and closing release.
A double opening release can be used for E2.2, E4.2 and E6.2 circuit-breakers; an
undervoltage release cannot be used in this case.
5
Electrical diagram reference: figure 72, 79
General characteristics
Power supply (Un)
AC
DC
24V
•
•
30V
•
•
48V
•
•
60V
•
•
110V…120V
•
•
220V…240V
•
•
240V…250V
•
•
380V…400V
•
-
415V…440V
•
-
480V…500V
•
-
Operating limits (IEC60947-2 standards)
YO/YO2: 70%...110% Un
YC/YC2: 85%...110% Un
Inrush power (Ps)
300VA
300W
Continuous power (Pc)
3.5VA
3.5W
Opening time (YO/YO2)
E1.2
20 ms
E2.2 … E6.2
35 ms
Closing time (YC/YC2)
E1.2
50 ms
E2.2 … E6.2
50 ms
5/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 10
15/04/2013 16:51:46
Opening and closing release test unit - YO/YC Test Unit
The opening and closing releases test unit helps ensure that the various version of releases are
running smoothly, to guarantee a high level of reliability in controlling circuit-breaker opening.
The test unit ensures the continuity of the opening and closing releases with a rated operating
voltage between 24V and 250V (AC and DC), as well as verifies the functions of the opening
and closing coil electronic circuit.
Continuity is checked cyclically with an interval of 20s between tests. The unit has optic
signals via LEDs on the front, which provide the following information:
POWER ON: power supply present
TESTING: testing in progress
TEST FAILED: signal following a failed test or lack of auziliary power supply
ALARM: signal given following three failed tests.
Two relays with one change-over area also available on board the unit, to allow remote
signalling of the following events:
Failure of a test - resetting takes place automatically when the alarm stops
Failure of three tests - resetting occurs only by pressing the manual RESET on the unit.
5
Charachteristics of device
Auxiliary power supply
24V...250V AC/DC
Specification of the signalling relays
Maximum interruped current
6A
Maximum interrupted voltage
250V AC
ABB Catalogue | 1SDC200023D0201 | 5/11
Emax2_cap05.indd 11
15/04/2013 16:51:46
Accessories
Accessories for circuit-breakers
1SDC200510F001
Undervoltage release – YU
The undervoltage release opens the circuit-breaker when there is a significant voltage drop or
power failure. It can be used for safe remote tripping, for locking on closing or to control the
voltage in the primary and secondary circuits. The power supply for the release is therefore
obtained on the supply side of the circuit-breaker or from an independent source.
Circuit-breaker closing is permitted only when the release is powered.
General characteristics
Power supply (Un)
5
AC
DC
24V
•
•
30V
•
•
48V
•
•
60V
•
•
110V…120V
•
•
220V…240V
•
•
240V…250V
•
-
380V…400V
•
-
415V…440V
•
-
480V…500V
•
-
Operating limits (IEC60947-2 standards)
70%...110% Un
Inrush power (Ps)
300VA
300W
Continuous power (Pc)
3.5VA
3.5W
Opening time (YU)
E1.2
30 ms
E2.2 … E6.2
50 ms
Electrical diagram reference: figure 73
5/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 12
15/04/2013 16:51:46
Time-delay device for undervoltage release (UVD)
The undervoltage release can be combined with an electronic time-delay device for installation
outside the circuit-breaker, allowing delayed trip unit tripping with adjustable preset times.
Use of the delayed undervoltage trip unit is recommended to prevent tripping when the power
supply network for the trip unit is subject to brief voltage drops or power supply failures.
Circuit-breaker closing is inhibited when it is not powered. The time-delay device must be used
with an undervoltage release with the same voltage.
General characteristics
Power supply (UVD)
AC
DC
24-30V
-
•
48V
•
•
60V
•
•
110-127V
•
•
220-250V
•
•
Adjustable opening time (YU + D):
5
0.5-1-1.5-2-3 s
Resetting remotely- YR
The reset coil YR permits remote resetting of the circuit-breaker after a release has tripped due
to an overcurrent condition.
It is available, for all automatic circuit-breakers, with different voltage supply:
General characteristics
1SDC200512F001
1SDC200511F001
Power supply (Un)
AC
DC
24V
•
•
110V
•
•
250V
•
•
Operating limits
90%...110% Un
Electrical diagram reference: figure 12 and 13
ABB Catalogue | 1SDC200023D0201 | 5/13
Emax2_cap05.indd 13
15/04/2013 16:51:47
Accessories
Accessories for circuit-breakers
1SDC200513F001
Motor – M
The motor automatically loads the closing springs of the circuit-breaker. The device, which
can be installed from the front, automatically reloads the springs of the operating device when
they are unloaded and power is present. In the event no power is present, the springs can be
manually loaded by a dedicated lever on the operating device. The motor is always supplied
with limit switch contact S33 M/2 which signals the status of the springs.
General characteristics
Power supply (Un)
1SDC200514F001
5
AC
DC
24V-30V
•
•
48V-60V
•
•
100V…130V
•
•
220V…250V
•
•
380V…400V
•
-
440V…480V (E2.2 ... E6.2)
•
-
Operating limits (IEC60947-2 standards)
85%...110% Un
Inrush power (Ps)
300VA
500W
Continuous power (Pc)
100VA
100W
Loading time
E1.2
8 sec
E2.2 … E6.2
7 sec
Electrical diagram reference: figure 12 and 13
5/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 14
15/04/2013 16:51:47
1SDC200515F001
Safety
1SDC200521F001
1SDC200520F001
1SDC200519F001
1SDC200518F001
1SDC200517F001
1SDC200516F001
Key lock in open position - KLC
Thanks to these safety devices, the SACE Emax 2 circuit-breaker can be locked in the open
position. The lock can also be used during maintenance activities when the shield of the
accessories area is removed. The device is available with lock with different keys – KLC-D (for
only one circuit-breaker) or with the same keys – KLC-S (for several circuit-breakers). In this
latter case, four different key numbers are available.
SACE Emax 2 also allows additional key locks to be installed. With the KLC-A type, the
following key locks can be used:
– Ronis
– Profalux
– Kirk
– Castell
In this case, the key locks must be supplied by the customer.
5
Padlocks - PLC
These padlocks allow the circuit-breaker to be kept open by acting directly on the mechanical
operating device opening pushbutton. Three different padlock versions are available:
– Locking device with plastic structure for up to a maximum of three padlocks of 4 mm
– Locking device with metal structure for up to a maximum of two padlocks of 8 mm
– Locking device with metal structure for one padlock of 7 mm or for padlock holders
The padlocks are always supplied by the customer.
Key lock in racked-in / test / racked-out position - KLP
This device enables the mobile part to be locked in one of the three positions: racked-in, test
and racked-out.
This device can be supplied with locks with different keys – KLP-D or with the same keys –
KLP-S. Each circuit-breaker can be equipped with a maximum of two key locks.
Locking in the racked-in, test and racked-out positions can be achieved by using other key locks
– KLP-A. This device is made for Ronis, Profalux, Kirk and Castell keys, which are to be provided
by the customer. With the exception of the Castell version, every circuit-breaker can accept up
to two key locks.
Padlock in racked-in / test / racked-out position - PLP
This device can hold up to three padlocks of 8 mm diameter. The structure housing the
padlocks can also be used with KLP keylocks. Furthermore, it enables the lock of the moving
part in the racked-out position only by means of the additional key lock in racked-out position.
Shutter lock – SL
When the mobile part is in the test position, the shutters of the fixed part close, maintaining
the insulation distance and physically segregating the live parts of the fixed part and the rear
section of the mobile part. Furthermore, using two dedicated mechanisms, the upper and
lower shutters can be locked independently of one another. This is always supplied with the
fixed part of the SACE Emax 2 circuit-breakers and locks the shutters, using a maximum of
three padlocks of 4 mm, 6 mm or 8 mm.
ABB Catalogue | 1SDC200023D0201 | 5/15
Emax2_cap05.indd 15
15/04/2013 16:51:50
Accessories
Accessories for circuit-breakers
Protection devices
1SDC200522F001
External shutter lock - SLE
This accessory is optional and, using padlocks of 4 mm, 6 mm or 8 mm, allows the shutters to
be locked directly from the outside of the fixed part, avoiding the need to work inside.
For both lock versions, the padlocks are supplied by the customer.
Lock for racking-out mechanism with circuit-breaker in closed position
All SACE Emax 2 withdrawable circuit-breakers are always supplied with a lock that prevents
the mobile part from being racked in and racked out when the circuit-breaker is in the closed
position. To rack in the mobile part, the circuit-breaker must be in the open position.
5
1SDC200523F001
Lock for racking in / racking out the mobile part when the door is open - DLR
This accessory, which is mounted on the fixed part, prevents the mobile part from being
racked in or out when the switchgear door is open.
Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP
This safety device prevents the switchgear door from being opened when the mobile part of
the withdrawable version of the circuit-breaker is in the racked-in or test position.
The circuit-breaker can be racked in when the door is open, which is then closed. This
accessory can be installed on both the right-hand or left-hand side of the fixed part. It is
available for circuit-breakers E2.2, E4.2 and E6.2. It is an alternative to the mechanical
interlock.
Lock to prevent door opening when circuit-breaker is in closed position - DLC
This prevents the compartment door from being opened when the circuit-breaker is in the
closed position (and with the circuit-breaker racked in for withdrawable circuit-breakers).
It also locks circuit-breaker closed when the compartment door is open.
1SDC200524F001
Anti-insertion lock
The withdrawable circuit-breakers are equipped with special locks that allow the mobile part to
be inserted only into the corresponding fixed part.
Mechanical operation counter - MOC
The number of mechanical operations is often one of the elements that determines the
frequency of ordinary maintenance operations on circuit-breakers. With this mechanical
operation counter, which is always visible on the front of the circuit-breaker, the user knows
how many mechanical operations the device has performed.
5/16 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 16
15/04/2013 16:51:51
1SDC200525F001
1SDC200526F001
Protection device for opening and closing pushbuttons - PBC
This accessory is applied to the safety cover of the circuit-breaker and is available in two
versions:
– Pushbutton protection device, which prevents operations on both opening and closing
pushbuttons unless the special key is used.
– Padlockable pushbutton protection device, which inhibits one or both of the circuit-breaker
switching pushbuttons.
- PBC is not compatible with PLC padlocks.
5
1SDC200528F001
1SDC200527F001
IP30 Protection
Always supplied with the circuit-breaker, the cover frame is applied to the door of the
switchgear to achieve IP30 degree of protection on the front part of the circuit-breaker.
1SDC200531F001
1SDC200530F001
1SDC200529F001
IP54 Protection
This transparent cover completely protects the front of the circuit-breaker, enabling IP54
degree of protection to be achieved. This accessory is provided with double key lock (same or
different keys).
Terminal covers – HTC / LTC
These accessories are applied in the terminal area, thereby reducing the risk of direct contact
with the live parts of the circuit-breaker. Two versions are available for E1.2: HTC high terminal
covers and LTC low terminal covers.
Separators - PB
These protection devices increase the insulation distance between adjacent phases. They are
available for E1.2.
ABB Catalogue | 1SDC200023D0201 | 5/17
Emax2_cap05.indd 17
15/04/2013 16:51:53
Accessories
Accessories for circuit-breakers
Connections
The SACE Emax 2 circuit-breakers offer a wide variety of terminals, thereby always guaranteeing an optimal solution for
connection to the power circuit.
Solution for fixed circuit-breakers
Type
Abbreviation
E1.2
E2.2
E4.2
E6.2
Single stab design
Rear orientable terminal *
HR
VR
Iu = 2000A
Iu = 3200A
Iu = 5000A
Iu = 4000A
Iu = 6300A
Multiple stab design
Iu = 2500A
5
Horizontal rear spread terminal
SHR
Vertical rear spread terminal
SVR
Extended front terminal
EF
Front terminal
F
Front spread terminal
ES
Terminal for cable
FcCuAl 4x240mm2
FcCuAl
Standard configuration
Configuration on request
(*) The orientable terminals are supplied as standard in the HR – HR configuration.
5/18 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 18
15/04/2013 16:51:54
Solutions for fixed parts, withdrawable circuit-breakers
Type
Abbreviation
E1.2
E2.2
E4.2
E6.2
Single stab design
Rear orientable terminal *
HR
VR
Iu = 2000A
Iu = 5000A
Multiple stab design
Iu = 2500A
Horizontal rear terminal
Iu = 3200A
Iu = 4000A
Iu = 3200A**
Iu = 6300A
or X performance
SHR
5
Vertical rear spread terminal
SVR
Front terminal
F
Extended front terminal
EF
Front spread terminal
ES
Terminal for cable
FcCuAl 4x240mm2
Fc CuAl
Flat terminal
FL
Standard configuration
Configuration on request
(*) The orientable terminals are supplied as standard in the HR – HR configuration.
(**) Fixed parts with Iu 3200A acesssorized with rear orientable terminals with multiple stabs guarantee higher performances in switchboard installations.
ABB Catalogue | 1SDC200023D0201 | 5/19
Emax2_cap05.indd 19
15/04/2013 16:51:56
Accessories
Accessories for circuit-breakers
Interlocks and switching devices
Mechanical interlocks
These interlock systems enable various opening and closing configurations to be obtained between two or three
circuit-breakers. Four types of interlock configuration are available:
Types of interlock
Possible application
Logic
Circuit-breakers
Type A
Excludes the possibility of having two
circuit-breakers in the closed position
at the same time.
Main line power supply and emergency
power supply.
G
5
1
Available between
circuit-breakers of
different sizes and with
any fixed / withdrawable
version
1
2
O
O
I
O
O
I
1
2
3
O
O
O
I
O
O
O
O
I
2
Type B
Permits a pair of circuit-breakers to be closed
if the third is open. The latter can only be
closed when the pair is open.
Two power supplies from transformers
and one emergency power supply.
G
2
1
3
I
O
I
O
I
O
1
2
3
Available between
E2.2, E4.2 and E6.2
circuit-breakers and with
any fixed / withdrawable
version
Type C
Permits two out of three circuit-breakers
to be closed at the same time.
Two half-busbars can be powered by a single
transformer (bus-tie closed) or by both at the
same time (bus-tie open).
1
2
3
O
O
O
I
O
O
O
I
O
O
O
I
O
I
I
I
I
O
I
O
I
1
2
3
O
O
O
I
O
O
O
I
O
O
O
I
Available between
E2.2, E4.2 and E6.2
circuit-breakers and with
any fixed / withdrawable
version
Type D
Permits one out of three interlocked
circuit-breakers to be closed.
Three power supplies on the same busbar
that must not operate in parallel.
G
1
2
Available between
E2.2, E4.2 and E6.2
circuit-breakers and with
any fixed / withdrawable
version
3
5/20 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 20
15/04/2013 16:51:57
The mechanical interlocks offer multiple solutions for installation that simplify their integration into the switchgear. The interlocks
can be mounted:
– vertically VR
– horizontally HR
– mixed L
Different types of interlocks can be supplied according to the maximum distance between two interlocked breakers:
Configuration
Type A
Type B, C, D
Horizontal
2750mm
1600mm
Vertical
Breakers
-
1000mm
E1.2
•
-
E2.2
•
•
E4.2
•
•
E6.2
•
•
5
For B, C and D types, the maximum distance between the two furthest breakers is 3200mm for horizontal configurations and
2000mm for vertical configurations. All cables can be cut to guarantee easy installation in switchboards. Mechanical interlocks
are not compatible with AUX 15Q or DLP and DLC locks.
Automatic Transfer Switches ATS
The ATS (Automatic Transfer Switch) is a network-unit transfer device used in installations where switching from the main power
line to an emergency line is required in order to ensure that power is supplied to the loads in the case of power abnormalities
from the main line.
These devices are able to control the entire transfer procedure automatically, but also offer commands for performing the
procedure manually. In the event of anomalies in the main line voltage, the opening of the main line circuit-breaker, the starting
of the generator set (if present) and the closing of the emergency line are activated according to the parameters set by the user.
In the same way, when the main line returns to normal, the reverse transfer procedure is performed automatically.
The new generation of ATSs (ATS021 and ATS022) offers the most advanced and complete solution for ensuring service
continuity. The ATS021 and ATS022 devices can be used with all automatic circuit-breakers and switch-disconnectors of the
Tmax XT family.
The ATS021 and ATS022 devices have been designed to be self-powered. ATS022 is also designed for the connection of an
auxiliary supply, which enables the use of further functions.
The ATS021 and ATS022 devices carry out control of both power supply lines and analyze:
– phase imbalance;
– frequency imbalance;
– phase loss.
In addition to the standard control functions, the ATS022 unit also permits:
– the priority line to be selected;
– a third circuit-breaker to be controlled;
– the device to be integrated into a supervision system with Modbus communication (auxiliary supply needed);
– parameters to be read and set, and measurements and alarms to be displayed by means of a graphical display.
Typical applications are: supply of UPS (Uninterrupted Power Supply) units, operating rooms and primary hospital services,
emergency power for civil buildings, airports, hotels, databases and telecommunication systems and power supply of industrial
lines in continuous processes.
For correct configuration, each circuit-breaker connected to the ATS021 or ATS022 device must be fitted with the following
accessories:
– mechanical interlock;
– motorized control of opening and closing ;
– contact for signalling status (open / closed) and contact for signalling tripping;
– contact for signalling circuit-breaker racked in (for withdrawable circuit-breaker).
ABB Catalogue | 1SDC200023D0201 | 5/21
Emax2_cap05.indd 21
15/04/2013 16:51:57
1SDC200537F001
1SDC200538F001
Accessories
Accessories for circuit-breakers
Technical characteristics
General
ATS021
ATS022
Auxiliary supply voltage
Not required
Supply voltage, Un
Max 480 VAC
Not required
(24-110V DC is required only
for Modbus communication and
systems of 16 2/3 Hz)
Max 480 VAC
Frequency, fn
Dimensions
5
H
L
D
50, 60 Hz
16 2/3, 50, 60, 400 Hz
H mm
96
96
L mm
144
144
D mm
170
170
Type of installation
Installation on front of switchgear Installation on front of switchgear
Installation on DIN rail
Installation on DIN rail
Operating mode
Automatic/Manual
Automatic/Manual
•
•
•
•
Characteristics Monitoring of normal and emergency line
Control of circuit-breakers on normal and emergency line
Environmental
conditions
Operating
thresholds
Tests
Standards
Setting start-up of generator
•
•
Setting switch-off of generator with settable time delay
•
•
Third circuit-breaker
-
•
Selection priority line
-
•
Modbus Rs485 communication
-
•
Display
-
•
Grado di protezione
IP20
IP20
Operating temperature
-20 … +60 °C
-20 … +60 °C
Humidity
5% - 90% without condensation 5% - 90% without condensation
Undervoltage
-30% … -5% Un
-30% … -5% Un
Overvoltage
+5% …+30% Un
+5% …+30% Un
Frequency thresholds
-10% / +10% fn
-10% … +10% fn
Test Mode
•
•
Mode Test Gen set
•
•
Electronic devices for use in electrical installations
EN-IEC 50178
EN-IEC 50178
Electromagnetic compatibility
EN 50081-2
EN 50081-2
EN 50082-2
EN 50082-2
IEC 68-2-1
IEC 68-2-1
IEC 68-2-2
IEC 68-2-2
IEC 68-2-3
IEC 68-2-3
Environmental conditions
Electrical diagram reference: figures 100,101 and 102.
5/22 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 22
15/04/2013 16:51:57
Accessories
Accessories for Ekip trip units
The electronic trip unit accessories enable utilization of all the potential of Ekip protection trip units in terms of signalling,
connectivity, protection functions and testing.
Electronic trip unit
Ekip DIP
Ekip Touch
Ekip Hi-Touch
Ekip G Touch
Ekip G Hi-Touch
Power supply
Ekip Supply
Battery for Ekip trip units
Connectivity
Ekip Com
Ekip Com Redundant
Ekip Com Actuator
Ekip Link
5
Ekip Bluetooth
Signalling
Ekip Signalling 2K
Ekip Signalling 4K
(1)
Ekip Signalling 10K
Ekip Power Controller
Measurement and Protection
Ekip Measuring Pro
Ekip Measuring
Ekip AUP
Ekip RTC
Ekip Synchrocheck
Ekip LCD
Ekip Fan
(1)
Rating Plug
Homopolar toroid
Toroid for differential protection
Current sensor for neutral conductor
outside the circuit-breaker
Displaying and Supervision
Ekip Multimeter
Ekip Control Panel
Testing and Programming
Ekip TT
Ekip T&P
(1)
Standard accessory
Accessory on request
not available for E1.2
ABB Catalogue | 1SDC200023D0201 | 5/23
Emax2_cap05.indd 23
15/04/2013 16:51:57
Accessories
Accessories for Ekip trip units
All accessories are automatically recognized by the Ekip units without the need for any specific configuration. Based on the
installation method and connection of the trip units, the electronic accessories can be divided into:
Installation
Modules
Highlights
- The Ekip Supply module enables the trip units to be supplied with several
line voltage
Terminal box
Cartridge modules:
Ekip Com
Ekip Link
Ekip 2K
Ekip Supply
Ekip Fan
Ekip Synchrocheck
- If the Ekip Supply module is present, the other cartridge modules can be
installed
- The Ekip Supply module has a dedicated position in the installation area
in the terminal box; the other modules can be installed as desired in the
positions available
- In addition to the Ekip Supply module, up to 2 modules can be installed on
E1.2, and up to 3 on E2.2, E4.2 and E6.2
- Ekip fan module is available for E2.2, E4.2 and E6.2 as an aletnative to Ekip
supply module
5
- These are installed in specific housings from the front of the circuit-breaker
Accessorizing
area
Ekip LCD
Ekip Com Actuator
Ekip RTC
Ekip AUP
Ekip Measuring
Ekip Signalling 4K
Rating Plug
Battery for Ekip
- For all the trip units with a touch screen interface, the LCD interface
is available with any adjustment in the protection and measurements
functions
- Thanks to the optional modules Ekip RTC and Ekip AUP, all the Ekip trip
units can acquire and monitor the ready to close state and the racked-in/
test isolated/racked-out position of the circuit-breaker. The module to
acquire the open/closed position is supplied as standard for all Ekip trip
units.
- The Ekip Signalling 4k module increases the remote signalling possibilities
for E2.2, E4.2 and E6.2
Ekip trip unit test
connector
External
Ekip T&P
Ekip TT
Ekip Bluetooth
- These are connected to the front test connector of the trip units even with
the device in operation
Ekip Multimeter
Ekip Control Panel
Ekip 10K
- Ekip Multimeter can supply the trip unit to which it is connected
External neutral sensor
Homopolar toroid
Differential toroid
- These are connected to the trip unit by the terminal box of the circuitbreaker
- Compatible also with the SACE Tmax XT range
- Several Ekip Multimeter units and / or Ekip Signalling 10K can be
connected at the same time to the same Ekip trip unitsganciatore Ekip
5/24 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 24
15/04/2013 16:51:57
1SDC200539F001
Power supply
Ekip Supply Power Supply module
The Ekip Supply module enables all Ekip trip units and modules present on the terminal box to
be supplied with several auxiliary power in AC or DC available in the switchgear.
The module can be mounted at any time on the circuit-breaker terminal box and permits
installation of the cartridge modules; it is an alternative to the Ekip Fan module.
Two versions are available according to the primary voltage used:
– Ekip Supply 110-240V AC/DC
– Ekip Supply 24-48V DC
Electrical diagram reference: figures 31, 32
5
1SDC200540F001
Connectivity
The Ekip Com modules enable all SACE Emax 2 circuit-breakers to be integrated in an
industrial communication network for remote supervision and control of the circuit-breaker.
They are suitable for all distribution and generator protection versions of the Ekip Touch and
Hi-Touch trip units.
Since it is mounted to the terminal box, communication can be maintained with withdrawable
circuit-breakers, even while in the racked-out position.
Several Ekip Com modules can be installed at the same time, thereby enabling connection to
communication systems that use different protocols.
The Ekip Com modules are supplied complete with auxiliary position contacts Ekip AUP and
ready to close circuit-breaker contacts Ekip RTC.
The Ekip Com and Profibus module are equipped with a dip switch that allows the introduction
of a 120: resistor to terminate a Modbus RTU network.
For industrial applications where superior reliability of the communication network is required,
the Ekip Com R communication modules, installed together with the corresponding Ekip Com
modules, guarantee redundant connection to the network.
The Ekip Com modules enable Ekip trip units to be connected to networks that use the
following protocols:
Protocol
Ekip Com Module
Modbus RTU
Ekip Com Modbus RS-485
Ekip Com Redundant Module
Ekip Com R Modbus RS-485
Modbus TCP
Ekip Com Modbus TCP
Ekip com R Modbus TCP
Profibus-DP
Ekip Com Profibus
Ekip Com R Profibus
Profinet
Ekip Com Profinet
Ekip Com R Profinet
EtherNet / IP
Ekip Com EtherNet / IP
Ekip Com R EtherNet / IP
DeviceNet
Ekip Com DeviceNet
Ekip Com R DeviceNet
IEC61850
Ekip com IEC61850
Electrical diagram reference: figures from 51 to 57. Redundant version from 61 to 66.
ABB Catalogue | 1SDC200023D0201 | 5/25
Emax2_cap05.indd 25
15/04/2013 16:51:58
Accessories
Accessories for Ekip trip units
1SDC200541F001
Ekip Link Module
The Ekip Link module enables the SACE Emax 2 circuit-breaker to be connected to ABB
communication system for locally supervising switchgear by means of the Ekip Control Panel
and to act as Power Controller. It is suitable for all Ekip trip units and can be fitted at any
time to the circuit-breaker terminal box, even when Ekip Com communication modules are
present. In this way, it is possible to have both local supervision of the control panel by means
of the Ekip Control Panel and supervision of the system by means of the Ekip Com modules
connected to the communication network.
The Ekip Link modules are supplied complete with auxiliary position contacts Ekip AUP and
ready to close circuit-breaker contacts Ekip RTC.
Electrical diagram reference: figure 58
Ekip Com Actuator module
The Ekip Com Actuator module enables the SACE Emax 2 circuit-breakers to be opened and
closed remotely.
The Ekip com Actuator is optional and can be ordered for all Ekip trip units equipped with Ekip
Com or Ekip Link modules; it is installed on the front of the circuit-breaker in the right-hand
accessories area.
1SDC200542F001
5
Electrical diagram reference: figure 76, 78
1SDC200543F001
Ekip Bluetooth wireless communication unit
Ekip Bluetooth permits remote connection with the trip unit by portable PC, tablet or smart
phone on which Ekip Connect software has been installed. The device is connected to the
front test connector found on all Ekip trip units in SACE Emax 2 and SACE Tmax XT circuitbreakers and supplies power by means of a rechargeable Li-ion battery.
5/26 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 26
15/04/2013 16:51:59
Signalling
1SDC200544F001
Ekip 2K Signalling modules
The Ekip 2K Signalling modules supply two input and two output contacts for control and
remote signalling of alarms and circuit-breaker trips. They can be programmed from the trip
unit’s display. Furthermore, by means of the Ekip Connect software, combinations of events
can be freely configured. They are suitable for all distribution and generator protection versions
of the Ekip Touch and Hi-Touch trip units.
Three different Ekip 2K Signalling modules are available: Ekip 2K-1, Ekip 2K-2, Ekip 2K-3.
In this way, a maximum of three modules for E2.2, E4.2, E6.2, and two for E1.2 can be
installed at the same time.
Electrical diagram reference: figures 41, 42, 43
1SDC200545F001
Ekip 4K signalling module
The Ekip 4K Signalling module, available for E2.2 – E4.2 – E6.2, supplies four input contacts
and four output contacts for control and remote signalling. It can be programmed from the trip
unit’s display. Furthermore, by means of the Ekip Connect software, combinations of events
can be freely configured.
It is installed in the housing provided in the front left of distribution and generator protection
versions of the Ekip Touch and Hi-Touch trip units, without having to remove the trip unit itself.
5
1SDC200546F001
Electrical diagram reference: figure 2
Ekip 10K signalling unit
Ekip 10K Signalling is a signalling unit on a DIN rail for SACE Emax 2 automatic circuitbreakers. The unit provides ten contacts for electrical signalling of timing and tripping of
protection devices.
If connected via the Ekip Connect software, the contacts can be freely configured in association
with any event and alarm or combination of both.
Several Ekip 10K Signalling (max 4) can be installed at the same time on the same Ekip trip unit.
The Ekip 10K Signalling module can be powered both in direct current and in the alternating
current and can be connected to Ekip Touch and Hi-Touch trip units via internal bus or Ekip
Link modules.
Electrical diagram reference: figure 103
ABB Catalogue | 1SDC200023D0201 | 5/27
Emax2_cap05.indd 27
15/04/2013 16:52:00
Accessories
Accessories for Ekip trip units
Characteristics of output contacts
Number of contacts
Type
Monostable
Maximum switching power (resistive load)
1250VA
Maximum switching voltage
150V DC / 250V AC
Maximum switching current
30V DC
2A
50V DC
0.8A
150V DC
0.2A
250V AC
4A
Contact/coil insulation
Ekip 2K
Ekip 4K
2
output
+2
input
4
output
+4
input
Ekip 10K
10
output
+ 11
input
2000 Vrms (1min @50Hz)
Ekip 10K signalling unit power supply
1SDC200547F001
5
Auxiliary supply
24-48V DC, 110-240V AC/DC
Voltage range
21.5-53V DC, 105-265V AC/DC
Rated power
8W
Signalling contacts for Ekip trip units
Ekip trip units can acquire the status of circuit-breaker ready to close (RTC) and the racked-in,
test, or racked-out position though the optional signalling contacts Ekip RTC and Ekip AUP.
These contacts, housed in the accessories area of the circuit-breakers, are available with Ekip
Dip, Ekip Touch and Ekip Hi-Touch.
Ekip COM communication modules and Ekip Link modules are always supplied with Ekip AUP
and Ekip RTC contacts.
1SDC200548F001
Measurement and protection
Ekip Measuring module
The Ekip Measuring module enables the trip unit to measure the phase and neutral voltages,
powers and energy.
The Ekip Measuring module is installed on the front, right housing of the distribution protection
versions of the Ekip Touch trip units, without having to remove the trip unit itself. The voltage
connections are installed by default on the lower terminals.
The measuring module requires no external connection since it is connected internally to the
lower or upper terminals of Emax 2. If necessary, the voltage outlet connection can be moved
outside the circuit-breaker by using voltmetric transformers and the alternative connection
positioned in the terminal box. The use of external connections is obligatory for rated voltages
that are higher than 690V. The module must be disconnected for dielectric strength tests on
the main busbars.
Electrical diagram reference: figures 20, 21, 22, 23
5/28 | 1SDC200023D0201 | ABB Catalogue
1SDC200549F001
Ekip Measuring Pro module
The module has the same connection and installation characteristics as the Ekip Measuring
module. In addition, the Ekip Measuring Pro version has:
– Protection devices based on the voltage and power values
– Ekip trip unit power supply from busbar voltage (for line voltages greater than 85V)
– LED signalling voltage on main busbars.
The Ekip Hi-Touch, Ekip G Touch and Ekip G-Hi Touch trip units are provided as standard with
the Ekip Measuring Pro module.
1SDC200550F001
Electrical diagram reference: figures 20, 21, 22, 23
Ekip Synchrocheck
This module enables the control of the synchronism condition for placing two lines in parallel.
The module can be used with distribution and generator protection versions of the Ekip Touch
and Hi-Touch trip units equipped with the Ekip Measuring Pro module.
Ekip Synchrochek acquires the voltages of two phases of one line through an external
transformer and, through the Ekip Measuring Pro module, the voltages of another line. An
output contact is available, which is activated upon reaching synchronism, and enables the
circuit-breaker to be closed by means of wiring with the closing release.
Characteristics of output contacts
5
Number of contacts
Type
Monostable
Maximum switching power (resistive load)
120W /1250VA
Ekip Synchrocheck
Maximum switching voltage
150V DC / 250V AC
Maximum switching current
30V DC
3A
50V DC
1A
150V DC
0.3A
250V DC
Contact/coil insulation
1
output
4A
2000 Vrms (1min @50Hz)
(Phase)
220Vac
Ekip
Measuring
YC
External operating
mechanism (synchronizing
unit or manual operating
mechanism)
1SDC200551ENF001
Ekip
G Touch
(Neutral)
Supply
SYNCRO
Vbar1
Vbar2
Electrical diagram reference: figure 48
ABB Catalogue | 1SDC200023D0201 | 5/29
Emax2_cap05.indd 29
15/04/2013 16:52:01
1SDC200552F001
Accessories
Accessories for Ekip trip units
1SDC200553F001
5
Ekip LCD display interface
For installations in particularly aggressive environments, as low temperatures, high humidity or
presence of dust or chemical agents, the Ekip protection trip units can be requested with an
LCD black and white display interface with pushbuttons for navigation. This version guarantees
excellent immunity by integrating all functions, with regard to protection devices, measuring
devices and the possibility of introducing accessories, available on the colour touch screen.
Ekip Fan cooling module
The Ekip Fan cooling module continuously monitors the temperature inside the fixed parts of
E2.2, E4.2 and E6.2 that are equipped with cooling fans and activates them in the event of
overheating.
It is an alternative to the Ekip Supply module and enables the protection trip unit to be
supplied with DC auxiliary power available in the switchgear. Ekip Fan can be used with Ekip
Touch and Ekip Hi-Touch trip units.
The Ekip Fan 24V DC is available. If an Ekip Fan 24V DC module is installed, another two
cartridge modules can also be installed.
1SDC200554F001
Electrical diagram reference: figure 33
Rating Plug
The rating plugs are field interchangeable from the front on all trip units and enable the
protection thresholds to be adjusted according to the actual rated current of the system.
This function is particularly advantageous in installations that may require future expansion or
in cases in which the power supplied needs to be limited temporarily (e.g. mobile Gen Set).
The Overload (L) protection function can be disabled at any time by using an L OFF version of
the rating plug. There is a matching L OFF version for each standard version of rating plug.
Circuit-breaker
Rating plugs available (both in standard and L OFF versions)
E1.2
400-630-800-1000-1250-1600
E1.2 250
100-200-250
E2.2
400-630-800-1000-1250-1600-2000-2500
E2.2 250
100-200-250
E4.2
400-630-800-1000-1250-1600-2000-2500-3200-4000
E6.2
400-630-800-1000-1250-1600-2000-2500-3200-4000-5000-6300
Special rating plugs are also available for differential protection against earthing faults in
combination with a suitable toroid to be installed externally.
Circuit-breaker
Rating plug available for Rc protection
E1.2
400-630-800-1000-1250-1600
E1.2 250
100-200-250
E2.2
400-630-800-1000-1250-1600-2000-2500
E2.2 250
100-200-250
E4.2
400-630-800-1000-1250-1600-2000-2500-3200-4000
5/30 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 30
15/04/2013 16:52:03
1SDC200555F001
1SDC200556F001
Current sensor for neutral conductor outside the circuit-breaker
This is only for three-pole circuit-breakers; it enables protection of the neutral conductor to be
achieved through connection to the Ekip trip unit. It is supplied on request.
Electrical diagram reference: figure 27
Homopolar toroid for the earthing conductor of main power supply
The distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units
can be used with an external toroid positioned, for example, on the conductor that connects
the star centre of the MV/LV transformer to earth (homopolar transformer): in this case, the
earth protection is called Source Ground Return. Through two different combinations of
connections of its terminals, the In of the toroid can be set at 100 A, 250 A, 400 A, 800 A.
5
1SDC200557F001
Electrical diagram reference: figure 25
Toroid for differential protection
Connected to the Ekip Touch and Hi-Touch trip units equipped with a rating plug for differential
protection, this toroid enables earth fault currents of 3…30A to be monitored.
To be installed on the busbar system, it is an alternative to the homopolar toroid.
Electrical diagram reference: figure 24
ABB Catalogue | 1SDC200023D0201 | 5/31
Emax2_cap05.indd 31
15/04/2013 16:52:03
Accessories
Accessories for Ekip trip units
Displaying and supervision
1SDC200558F001
Ekip Multimeter Display on front of switchgear
Ekip Multimeter is a display unit to be installed on the front of the switchgear for SACE Emax
2 circuit-breakers equipped with Ekip electronic trip units. The device, 96mmx96mm sized, is
equipped with a large touch screen display and enables measurements to be displayed with
the same levels of precision. If connected to trip units with a display, Ekip Multimeter enables
the adjustment of parameters and protection thresholds.
Several Ekip Multimeter devices can be connected at the same time to the same Ekip
protection trip unit to display currents, voltage, powers and energy.
Ekip Multimeter can be powered either in direct current (24-48V DC or 110-240V DC) or in
alternating current (110-240V AC). It is equipped with a 24V DC output that supplies the trip
unit to which it is connected.
1SDC200559F001
5
Power supply
24-48V DC, 110-240V AC/DC
Tolerance
19.2-60V DC, 105-265V AC/DC
Rated Power
8W
Ekip Control Panel on front of switchgear
The Ekip Control Panel enables the SACE Emax 2 circuit-breakers connected to the Ekip Link
system to be controlled and monitored.
The panel is supplied already equipped with supervision software and requires no
programming. Ekip Control Panel requires a 24V DC power supply and is equipped with:
– 2 RJ45 EtherNet ports for connection to the Ekip Link system and to the local network for
remote control via web server option
– 1 RS485 serial port for integration of the Modbus network if it is to be used with circuitbreakers of the Tmax series
– 4 USB ports for downloading data.
5/32 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 32
15/04/2013 16:52:04
1SDC200561F001
1SDC200560F001
Testing and programming
Ekip TT testing and power supply unit
Ekip TT is a device that allows you to verify that the circuit-breaker trip mechanism is
functioning correctly (trip test).
It also allows a trip unit not provided with auxiliary power supply to be supplied with power so
that the last protection device tripped can be displayed directly on the screen or by the lighting
up of corresponding LEDs.
The device can be connected to the front test connector of any Ekip trip unit of SACE Emax 2;
it is supplied as standard with the versions for distribution and generator protection of the Ekip
Touch, Hi-Touch trip units to set protection functions setting.
Ekip T&P testing kit
Ekip T&P is a kit that includes different components for programming and testing the electronic
protection trip units.
The kit includes:
– Ekip T&P unit;
– Ekip TT unit;
– adaptors for Emax and Tmax trip units;
– USB cable to connect the T&P unit to the Ekip trip units;
– installation CD for Ekip Connect and Ekip T&P interface software.
The Ekip T&P unit is connected on one side to the USB port of a PC and on the other, by
means of the cable provided, to a protection trip unit of the SACE Emax 2 series.
The Ekip T&P unit performs the automatic testing, manual testing and trip testing of the device
to which it is connected and generates reports.
These functions are managed via the Ekip T&P Interface, which is activated directly by Ekip
Connect only in the presence of the Ekip T&P connected to a PC.
5
ABB Catalogue | 1SDC200023D0201 | 5/33
Emax2_cap05.indd 33
15/04/2013 16:52:04
Accessories
Spare parts
Spare parts
The following original and guaranteed spare parts are available:
– Front shield and lateral covers
– Opening solenoid for Ekip protection trip unit
– Arc chamber
– Complete pole
– Operating mechanism and closing springs
– Loading lever for closing springs
– Racking-out lever
– Racking-out handle and plates
– Jaw isolating contact for fixed part of withdrawable circuit-breaker
– Shutters for fixed part
– Trip units - current transformers wires
– Transparent protection for trip unit
– Mainboard for protection trip units
– Terminal box and e sliding contacts
– Grease and oil.
5
For further details, please refer to ABB SACE Spare Parts Catalogue.
5/34 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap05.indd 34
15/04/2013 16:52:04
Installation
Circuit-breaker
6/2
Sizes
6/3
Versions
6/4
Poles
6/5
Terminals
6/6
Degree of protection
6/7
Power losses
6/7
Temperature derating
6/8
Current-limiting curves
6/9
Installation environment
Temperature
6/10
Environmental conditions
6/10
Vibration
6/10
Electromagnetic compatibility
6/10
Installation in switchgear
6/11
Position
6/12
Power supply
6/12
Insulation distances and connection
6/12
Busbar types
6/14
Accessories
6/14
Performance in switchgear
6/15
6
ABB Catalogue | 1SDC200023D0201 | 6/1
Emax2_cap06.indd 1
15/04/2013 09:53:47
Installation
Circuit-breaker
The new SACE Emax 2 family maintains the characteristics of strength and reliability
that have always distinguished the tradition of ABB SACE air circuit-breakers.
The new SACE Emax 2 circuit-breakers, available in four sizes, are extremely compact due to their new dimensions: with
reduced depths and heights, combined with rationalized widths, they provide the answer to the most stringent installation
requirements.
Safety is guaranteed thanks to the double insulation of the live parts and total segregation of the phases. Furthermore, the new
functional design of the SACE Emax2 circuit-breakers has been developed with the purpose of improving installation operations
and use of the devices and accessories; making them simple, intuitive and safe.
Distinctive characteristics
- Ekip protection trip units are interchangeable from front of circuit-breaker
- Rapid configuration of the Ekip trip units
6
- Electronic modules can be installed on terminal box without removing the electronic trip units and
protection shield
Benefits
Reduced times during the stages of:
- installation
- wiring
- configuration
- commissioning
- maintenance
- Electrical plug-in accessories can be installed from the front of circuit-breaker
- New push-in terminal box allows rapid auxiliary connections
Simplicity of
use and safety - Horizontal or vertical rear connections can be modified on-site by turning 90°
Increased level of safety
- Accessorizing logic common to the entire family of circuit-breakers
- Accessory cabinet and terminal box are stamped with accessory codes for easy identification
- Accessories area is separated functionally from the safety area
- Mechanical safety locks in open position are active when the shield is removed
- Guided racking in and out of the mobile part
6/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 2
15/04/2013 09:53:47
Sizes
The SACE Emax2 circuit-breakers, available in 4 sizes up to 6300A, provide:
- Versatility, where installation space is a critical and influential factor, such as naval applications, wind turbine towers or
switchgear
- Opportunities, optimization of the dimensions of the electrical switchgear results in a potential reduction in the consumption
of the materials used.
6300A
6
4000A
1SDC200562F001
2500A
1600A
Emax E1.2
Emax E2.2
Emax E4.2
Emax E6.2
ABB Catalogue | 1SDC200023D0201 | 6/3
Emax2_cap06.indd 3
15/04/2013 09:53:47
Installation
Circuit-breaker
Versions
The SACE Emax2 circuit-breakers are available in both fixed and withdrawable versions. The withdrawable version is
recommended in applications in which service continuity is a fundamental requirement: replacement of the moving part with
a new device does not require any intervention on power connections or on auxiliary connections, thus permitting reset in the
shortest time possible.
The fixed version, which is connected directly to power system through the circuit-breaker terminals, is recommended in
applications in which the need for space means that compact products are required without compromising the performance
and possibility of fitting accessories.
6
Fixed
Withdrawable
2
4
4
1
3
7
7
6
5
1.
2.
3.
4.
5.
6.
7.
8.
1SDC200564F001
8
1SDC200563F001
8
Moving part
Sliding contacts
Fixed part
Terminal box
Racking-out mechanism
Racking-out guide rails
Pushbuttons
Data label and accessories
6/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 4
15/04/2013 09:53:49
Poles
SACE Emax 2 circuit-breakers are available in three-pole and four-pole versions and can be used in all types of distribution
systems. Furthermore, thanks to the possibility of connecting the external current sensor, three-pole circuit-breakers can be
used efficiently even in systems in which the neutral conductor cannot be isolated.
The four-pole circuit-breakers E1.2, E2.2 and E4.2 are always provided with full-size neutral pole with rated uninterrupted
current-carrying capacity identical to the phase poles. The E6.2 circuit-breakers, thanks to their construction modularity, are
available with neutral set at 50% - normal supply – and with full-size neutral, so that the customer does not need to oversize
the neutral unless strictly necessary.
The apparatus supplied as standard are suitable for connection of phases in the sequence L1, L2, L3 for three-pole circuitbreakers, or N, L1, L2 and L3 for four-pole circuit-breakers with neutral on the left; a special optional kit enables the position of
the circuit-breaker neutral to be changed to the right, making the sequence L1,L2,L3,N available.
6
Circuit-breaker
Standard version
Three-pole
Emax E1.2
L1
L2
Optional version with neutral on the right
Four-pole
L3
N
L1
Four-pole
L2
L3
L1
L2
L3
N
Emax E2.2
Emax E4.2
Emax E6.2
ABB Catalogue | 1SDC200023D0201 | 6/5
Emax2_cap06.indd 5
15/04/2013 09:53:49
Installation
Circuit-breaker
Terminals
The integration of the circuit-breaker in the electrical system is simplified thanks to the connection terminals of the circuitbreakers. The silver-plated copper terminals are designed to assist installation of connecting bars according to the change in
the rated capacity of the circuit-breaker. Each terminal has been created to the standard width of busbar for that amperage
and is equipped with one, two or three terminal stabs for easy connection to multiple bus runs that may be required for
the application.For particular installation requirements, the circuit-breakers can be equipped with different combinations of
terminals for the upper and lower part.
6
Type
Abbreviation
E1.2
E2.2
E4.2
E6.2
Rear orientated
terminal (1)
HR
VR
F, W
F, W
F, W
F, W
Horizontal rear
spread terminal
SHR
W
F, W
Vertical rear
spread terminal
SVR
Front terminal
F
F
F, W
F, W
F, W
Extended front
terminal
EF
F, W
Front spread
terminal
ES
F, W
Terminal for cable
FcCuAl 4x240mm2
Fc CuAl
F, W
Flat terminal
FL
W
W
W
F, W
(1) The reare orientated terminals are supplied as sandard in the HR-HR configuration.
6/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 6
15/04/2013 09:53:50
Degree of protection
The SACE Emax2 circuit-breakers guarantee the following degrees of protection:
- IP20 for circuit-breakers in fixed or withdrawable versions, excluding the terminals.
- IP30 for the front parts of the circuit-breaker when installed in switchgear with IP30 flange mounted on the door.
- IP54 for circuit-breakers equipped with optional IP54 transparent flange fixed on the door in front of the switchgear.
Power losses
To guarantee the performance of the electrical switchgear in terms of rated uninterrupted current-carrying capacity, the design
of the electrical switchgear must take into consideration the power losses by the apparatus and by live parts installed.
These power losses are measured according to IEC 60947 product standard, the values given in the table refer to total power
for three and four pole circuit-breakers with balanced loads with a current flow equal to rated uninterrupted current "Iu" at
50/60Hz.
Circuit-breaker type
Iu
630A
800A
1000A
1250A
1600A
2000A
2500A
3200A
4000A
5000A
6300A
[W]
31
50
78
122
201
-
-
-
-
-
-
E2.2 B/N/S/H [W]
-
34
53
83
136
212
267
-
-
-
-
E4.2 N/S/H/V
[W]
-
-
-
-
-
-
-
425
465
-
-
E6.2 H/V/X
[W]
-
-
-
-
-
-
-
-
309
483
767
E1.2 B/C/N
[W]
62
100
156
244
400
-
-
-
-
-
-
E2.2 B/N/S/H [W]
-
72
113
176
288
450
550
-
-
-
-
E4.2 N/S/H/V
[W]
-
-
-
-
-
-
-
743
900
-
-
E6.2 H/V/X
[W]
-
-
-
-
-
-
-
-
544
850
1350
E1.2 B/C/N
Fixed
Withdrawable
6
ABB Catalogue | 1SDC200023D0201 | 6/7
Emax2_cap06.indd 7
15/04/2013 09:53:50
Installation
Circuit-breaker
Temperature derating
Under certain installation conditions, the circuit-breakers can operate at higher temperatures than the reference temperature of
40°C. In this case the current-carrying capacity of the circuit-breaker may be lower than the rated current-carrying capacity at
the reference temperature: therefore the derating coefficients shown in the table must be applied. Percentage values refer to
withdrawable circuit breakers.
Emax 2 E1.2
6
Temperature [°C]
<40
45
50
55
60
65
70
E1.2 250
100%
100%
100%
100%
100%
100%
100%
E1.2 630
100%
100%
100%
100%
100%
100%
100%
E1.2 800
100%
100%
100%
100%
100%
100%
100%
E1.2 1000
100%
100%
100%
100%
100%
100%
100%
E1.2 1250
100%
100%
100%
100%
100%
100%
100%
E1.2 1600
100%
100%
100%
98%
95%
93%
90%
Emax 2 E2.2
Temperature [°C]
<40
45
50
55
60
65
70
E2.2 250
100%
100%
100%
100%
100%
100%
100%
E2.2 800
100%
100%
100%
100%
100%
100%
100%
E2.2 1000
100%
100%
100%
100%
100%
100%
100%
E2.2 1250
100%
100%
100%
100%
100%
100%
100%
E2.2 1600
100%
100%
100%
100%
100%
100%
98%
E2.2 2000
100%
100%
100%
100%
95%
91%
87%
E2.2 2500
100%
100%
100%
100%
98%
94%
90%
Emax 2 E4.2
Temperature [°C]
<40
45
50
55
60
65
70
E4.2 2000
100%
100%
100%
100%
100%
100%
100%
E4.2 2500
100%
100%
100%
100%
100%
100%
100%
E4.2 3200
100%
100%
97%
93%
89%
86%
82%
E4.2 4000
100%
100%
94%
90%
86%
83%
80%
Emax 2 E6.2
Temperature [°C]
<40
45
50
55
60
65
70
E6.2 4000
100%
100%
100%
100%
100%
100%
100%
E6.2 5000
100%
100%
100%
100%
100%
98%
95%
E6.2 6300
100%
100%
95%
91%
87%
84%
81%
6/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 8
15/04/2013 09:53:50
Current-limiting curves
The SACE Emax2 series features a series of current-limiting circuit-breakers in sizes E1.2 up to 1600A. These circuit-breakers
are distinguished constructively by:
– Dedicated stored energy operating mechanism, which reduces opening times.
– Specific main contacts which, utilizing the electrodynamic forces generated by the short-circuit current, accelerate opening of
the main contacts.
These features ensure rapid interruption which consequently reduces electromechanical and thermal stress on the system
during a short-circuit. The current-limiting circuit-breakers are distinguished by short-time withstand currents Icw that are not
particularly high and therefore not indicated for applications in which chronoamperometric selectivity is required with several
downstream devices or in which devices are present with high inrush current in the start-up stage.
Current-limiting curves
Current-limiting curves of specific let-through energy
E1.2 L
E1.2 L
6
690V
380/415V
690V
1SDC200567F001
1SDC200566F001
380/415V
ABB Catalogue | 1SDC200023D0201 | 6/9
Emax2_cap06.indd 9
15/04/2013 09:53:51
Installation
Installation environment
SACE Emax 2 circuit-breakers have been designed and tested in accordance with major international Standards to manage with
maximum reliability the electrical plant. The installation requirements prescribed by the international Standards are listed below.
In addition, ABB provides instructions for the use of circuit-breakers in nonstandard environments, as for example personalized
maintenance program or installation solutions aimed at increasing performances and extending the lifecycle of the circuit-breaker.
Temperature
SACE Emax2 circuit-breakers can operate in the following environmental conditions:
Temperature (°C)
Operating
Active Display
Storage
Emax 2 with Ekip DIP
-25°C … +70°C
-
-40°C … +70°C
Emax 2 with Ekip Touch
-25°C … +70°C
-20°C … +70°C
-30°C … +70°C
Emax 2 with LCD
-25°C … +70°C
-25°C … +70°C
-40°C … +70°C
Emax 2 swith-disconnectors
-25°C … +70°C
-
-40°C … +70°C
Environmental conditions
6
The devices can be installed in industrial environments with pollution level 3, IEC 60947. SACE Emax 2 circuit-breakers also
comply with:
– IEC60721-3-6 class 6C3
– IEC60721-3-2 class 3C2
Altitude
SACE Emax2 air circuit-breakers do not undergo changes in rated performance up to 2000 metres. Beyond this altitude, the
properties of the atmosphere in terms of composition, dielectric capacitance, cooling power and pressure vary and, therefore,
the performance of the circuit-breakers is subject to derating, which can be measured by means of the variation in maximum
rated service voltage and rated uninterrupted current.
Altitude
Rated service voltage - Ue
[m]
2000
3000
4000
5000
Versions 690V
[V]
690
607
538
470
Versions 1150V
[V]
1150
1012
897
782
[% In]
100
98
93
90
Rated current
An installation at 3000 m of a 690 V AC rated service voltage can be an explicative example. The altitude, as shown in the table,
may cause a derating which precludes the use of a standard automatic circuit-breaker. To grant the use of a circuit-breaker at
690 V AC rated service voltage is therefore required a 1150V AC version that – despite the derating – fulfill the necessary rated
service voltage. In addition, the selection of the circuit-breakers has to be based on the short -circuit performance required by the
application.
Vibration
The circuit-breakers have been tested according to:
– IEC60068-2-6
- From 1 to 13 Hz with amplitude 1mm
- From 13 to 100 Hz with constant acceleration 0.7g
– IEC60721-3-1
- Storage: 1M3
– IEC60721-3-2
- Transport: 2M2
– IEC60721-3-3
- Operational conditions: 3M2
– Shipping registers or certifications
Electromagnetic compatibility
The use of specific devices in industrial installations may cause electromagnetic interference in the electrical system. SACE
Emax2 circuit-breakers have been developed and tested for electromagnetic compatibility in accordance with IEC 60947-2,
Appendices J and F.
6/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 10
15/04/2013 09:53:51
Installation
Installation in switchgear
Thanks to the four construction sizes and the reduced insulation distances required, SACE Emax2 circuit-breakers enable the
installation spaces of the compartments of electrical switchgear to be optimized, thereby providing a rational solution to the
customers’ application needs.
Emax E1.2
Emax E2.2
Emax E4.2
Emax E6.2
1600 A
2500 A
4000 A
6300A
1SDC200568F001
6
400...600
300...400
600...800
1000...1200
SACE Emax2 circuit-breakers enable the design of electrical switchgear to be improved, allowing it to be optimized not just
in terms of performance, but also in the use of the main materials:
– Copper: thanks to the possibility of developing compact units, the length of the distribution system / busbar can be
minimized.
– Metal frame and structure: reduced volumes also mean less surface space is used for panels and internal structures.
– Space: the optimization of the individual units benefits the entire switchgear, which is more compact and can therefore be
installed taking up less surface space.
Traditional circuit-breaker 3p Iu 2500A
Emax E2.2 3p Iu 2500A
Efficiencies with Emax 2:
Possibility of
saving in copper
Possibility of saving
in metal frame,
segregation and plates
1SDC200569F001
Possibility of saving in
the installation surface
600
400
200
ABB Catalogue | 1SDC200023D0201 | 6/11
Emax2_cap06.indd 11
15/04/2013 09:53:51
Installation
Installation in switchgear
Position
All SACE Emax2 circuit-breakers can be floor mounted in a vertical position inside
the switchgear compartment.
The E1.2 circuit-breaker can also be installed in a horizontal position and wall
mounted.
Power supply
The Emax2 circuit-breakers can be supplied, indifferently, from either upper or lower
terminals. In the event a measurement module is present, in order to make use of
all information when the circuit-breaker is in the open position, the voltage sockets
must be installed on the power supply side.
Insulation distances and connection
The circuit-breakers can be connected to the main power system using the most
common configurations and dimensions of copper bars. Installation of live parts
must ensure:
D
6
C
B
A
1SDC200570F001
– Minimum insulation distances between the phases
Rated insulation voltage Ui
Minimum distance [mm]
1000V
14mm according to IEC 61439; ABB suggests 25mm
– Insulation distance of installation cubicle
Fixed circuit-breakers
D
C
Withdrawable circuit-breakers
A
B
C
[mm]
3p
4P
E1.2
250
322
382.5*
E2.2
400
490
500
E4.2
500
600
500
E6.2
900
1000
E6.2/f
-
1200
A
B
[mm]
3p
4P
130
E1.2
280
221
E2.2
400
221
E4.2
500
500
221
E6.2
900
1000
500
355
500
221
E6.2/f
-
1200
500
355
C
D
350
440*
252
490
500
355
600
500
355
* 390mm for voltage less d440V AC
1SDC200571F001
* 332.5mm for voltage less d440V AC
D
B
A
6/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 12
15/04/2013 09:53:51
L [mm]: Max distance of the first anchorage plate from the circuit breaker terminals
– Anchorage plates
The electrodynamic force released during a short-circuit can cause high levels of
mechanical stress to the devices and structures of the switchgear. To minimize
this, fastening plates must be positioned near the circuit-breaker terminals.
E1.2
E2.2
E4.2
E6.2
6
Ipk [kA]: Peak current
1SDC200572ENF001
– Tightening torques
The following table indicates the values required for connecting the circuit-breaker
terminal and the connecting bars.
Terminals
E1.2
E2.2 / E4.2 / E6.2
Modifiable HR/VR rear
40 Nm
70 Nm
Spread rear
40 Nm
70 Nm
Front
40 Nm
70 Nm
Extended front
40 Nm
70 Nm
Spread front
70 Nm
70 Nm
Front for cables
43 Nm
70 Nm
– Segregation plates and separator plates
The rear part of the circuit-breaker has been designed with specific slots in which
insulating walls can be housed to facilitate segregation of live parts. In addition,
phase separators are available as an optional accessory for E1.2.
Earthing connection
To achieve continuity and equipotentiality of earthing between the Emax 2 circuitbreaker and the protection citcuit of the switchboard, customers can do either of
the options below:
– Connect the Emax 2 fixed circuit-breaker or the fixed part of the withdrawable
circuit-breaker to the protective circuit by means of a cable with suitable crosssectional area to fulfil the requirements of clause 10.5.2 fo the Standard IEC
61439-1.
– If the continuity of the circuit-breaker frame with the switchboard earthing is
guaranteed by the metal contact (support) between the circuit-breaker and
the metal structure of the switchboard (which is a part of the protective circuit)
no connection is necessary (provided that no panels of insulating material are
interposed between the circuit-breaker and the metal frame of the switchboard).
Emax E1.2, fixed version, does not require any earthing connection.
ABB Catalogue | 1SDC200023D0201 | 6/13
Emax2_cap06.indd 13
15/04/2013 09:53:51
Installation
Installation in switchgear
Busbar types
The circuit-breakers, via the terminals, can be connected to the main distribution system by busbars of different types: copper,
silver-plated copper and tinned aluminium when the main distribution system is made of aluminium.
The circuit-breakers can be connected directly with copper or aluminium cables in the case of E1.2 circuit-breakers, or
indirectly by cable-carrying bars in the case of E2.2, E4.2 e E6.2.
Accessories
6
The SACE Emax 2 circuit-breakers offer a wide range of accessories that improve safety levels for technicians working on the
switchgear and circuit-breakers. Furthermore, thanks to the different types of mechanical interlock available, pre-determined
coordination strategies can be achieved between the circuit-breakers. In detail:
– Horizontal and vertical interlocks between circuit-breakers
– Door lock with circuit-breaker in closed position
– Switchgear door lock in racked-in/out position
– Lock of racked-out mechanism with door open
– External lock of shutters
– Flange for switchgear door IP30 and IP54
1SDC200573F001
For further information of the operation of accessories, see chapter 5.
6/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 14
15/04/2013 09:53:52
Installation
Performance in switchgear
The many types of switchgear that can be created and the installation and environmental conditions can considerably influence
the performance of the circuit-breaker. In this regard, SACE Emax 2 circuit-breakers offer the best solution for improving the
capacity in switchgear.
The following application situations have been assessed by taking into consideration the main factors that can influence the
performance of the circuit-breaker in switchgear:
– Type of switchgear
– Switchgear degree of protection
– Segregation form 3
– Size of circuit-breaker
– Number of devices connected at the same time in the unit
– Type of terminal and connection
– Ambient temperature Ta (IEC61439-1 )
– Withdrawable circuit-breakers
– Maximum withstand temperature for the terminal 120° C
6
ABB Catalogue | 1SDC200023D0201 | 6/15
Emax2_cap06.indd 15
15/04/2013 09:53:52
Installation
Performance in switchgear
The following tables provide an indication of the performance of the
apparatus inside the switchgear. The data shown are a summary of
software model simulations and real tests.
HR Terminal
One circuit-breaker in the column
SACE Emax 2 E1.2 B C N Circuit-breaker
Switchgear dimensions 2200x400x600 (HxLxD)
Environment temperature
IP
Iu
IP31
630
800
Connection [mm]
2x40x5
2x50x5
2x50x10
1000
6
2x50x8
Compartment 2
Compartment 1
1SDC200574F001
2x50x10
1250
2x50x8
3x50x8
1600
2x50x10
Compartment
35 °C
45 °C
55 °C
630
630
630
800
800
800
1000
1000
1000
1250
1250
1200
1440
1360
1290
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Performances with EF, SHR and F terminals can be compared, with the same connection sections, to the performances of circuit-breaker with HR terminal.
Performances with ES terminals can be compared to the VR terminals.
Performances with FC CuAl terminals, with cables in the prescribed sections, can be compared to HR performances.
6/16 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 16
15/04/2013 09:53:53
HR Terminal
Two circuit-breakers in the column
Environment temperature
VR Terminal
One circuit-breaker in the column
Environment temperature
35 °C
45 °C
55 °C
630
630
630
630
630
630
800
800
800
800
800
800
970
930
900
1000
960
920
1200
1150
1100
1250
1200
1140
1330
1260
1220
1370
1315
1262
35 °C
630
45 °C
630
VR Terminal
Two circuit-breakers in the column
Environment temperature
55 °C
630
800
800
800
1000
1000
1000
1250
1250
1250
1520
1440
1330
35 °C
45 °C
55 °C
630
630
630
630
630
630
800
800
800
800
800
800
1000
1000
950
1000
1000
970
1250
1250
1150
1250
1250
1200
1430
1355
1265
1475
1415
1310
6
ABB Catalogue | 1SDC200023D0201 | 6/17
Emax2_cap06.indd 17
15/04/2013 09:53:53
Installation
Performance in switchgear
The following tables provide an indication of the performance of the
apparatus inside the switchgear. The data shown are a summary of
software model simulations and real tests.
HR Terminal
One circuit-breaker in the column
SACE Emax 2 E2.2 B N S H Circuit-breaker
Switchgear dimensions 2200x600xx900 (HxLxD)
Environment temperature
IP
Iu
Connection [mm]
IP31
Compartment
35 °C
45 °C
55 °C
800
800
800
1000
1000
1000
1250
1250
1250
1600
1540
1480
2000
1940
1850
2000
2000
1940
2500
2350
2200
2500
2460
2320
2
800
1x50x10
1
2
1000
2x50x5
1
2
1250
2x50x10
1
2
6
2x60x10
1600
Compartment 2
1
2
1x100x10
1
1SDC200574F001
2
Compartment 1
3x60x10
1
2
2x80x10
2000
1
2
3x60x10 *
1
2
2x80x10 *
1
2
3x60x10
1
2
4x100x5
2500
1
2
3x60x10 *
1
2
4x100x5 *
1
* Performances refer to SHR and SVR terminals.
Performances with F and FL terminals can be compared to the performance of circuit-breakers with HR terminals.
6/18 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 18
15/04/2013 09:53:54
HR Terminal
Two circuit-breakers in the column
Environment temperature
VR Terminal
One circuit-breaker in the column
Environment temperature
35 °C
45 °C
55 °C
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1250
1250
1250
1250
1250
1250
1470
1410
1360
1550
1490
1430
1920
1810
1720
1950
1850
1760
2000
1900
1810
2000
1945
1850
2280
2200
2100
2400
2310
2170
2394
2310
2205
2500
2430
2280
35 °C
800
1000
1250
45 °C
800
1000
1250
VR Terminal
Two circuit-breakers in the column
Environment temperature
55 °C
800
1000
1250
35 °C
45 °C
55 °C
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1250
1250
1250
1250
1250
1250
6
1600
1600
1520
2000
2000
1920
2000
2000
2000
2500
2450
2350
2500
2500
2460
1500
1470
1400
1580
1550
1475
1950
1860
1760
2000
1920
1810
2000
1950
1850
2000
2000
1900
2400
2270
2160
2500
2380
2270
2500
2390
2270
2500
2500
2380
ABB Catalogue | 1SDC200023D0201 | 6/19
Emax2_cap06.indd 19
15/04/2013 09:53:54
Installation
Performance in switchgear
The following tables provide an indication of the
performance of the apparatus inside the switchgear.
The data shown are a summary of software model
simulations and real tests.
HR Terminal
VR Terminal
One circuit-breaker in the column One circuit-breaker in the column
SACE Emax 2 E4.2 N S H V Circuit-breaker
Switchgear dimensions 2200x800xx900 (HxLxD)
Environment temperature
IP
Environment temperature
Iu
Connection Compartment 35 °C
[mm]
45 °C
55 °C
35 °C
45 °C
55 °C
2000
2x80x10
1
2000
2000
2000
2000
2000
2000
2500
2x100x10
1
2500
2450
2400
2500
2500
2500
3200
3x100x10
1
3050
2900
2755
3200
3080
2920
3200
3x100x10*
1
3200
3050
2850
3200
3200
3020
4000
4x100x10
1
3450
3200
2970
3650
3400
3200
IP31
6
Compartment 1
1SDC200574F001
Compartment 2
* Performances refer to withdrawable circuit-breakers with a fixed part accessorized with three stab rear terminals for 4000A (Example: 1SDA074021R1 - KIT VR 4000A)
Performances with F and FL terminals can be compared to the performances of circuit-breaker with HR terminal.
6/20 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 20
15/04/2013 09:53:55
The following tables provide an indication of the performance
of the apparatus inside the switchgear. The data shown are a
summary of software model simulations and real tests.
HR Terminal
VR Terminal
One circuit-breaker in the column One circuit-breaker in the column
SACE Emax 2 E6.2 H V X Circuit-breaker
Switchgear dimensions 2200x1200xx900 (HxLxD)
Environment temperature
IP
Environment temperature
Iu
Connection Compartment 35 °C
[mm]
45 °C
55 °C
35 °C
45 °C
55 °C
4000
4x100x10
4000
4000
4000
4000
4000
IP31
1
4000
6
Compartment 1
5000
5x100x10
1
5000
5000
4900
5000
5000
5000
6300
7x100x10
1
5650
5350
4850
6000
5700
5250
1SDC200574F001
Compartment 2
Performances with F and FL terminals can be compared to the performances of circuit-breaker with HR terminal.
ABB Catalogue | 1SDC200023D0201 | 6/21
Emax2_cap06.indd 21
15/04/2013 09:53:56
Installation
Performance in switchgear
The following tables provide an indication of the
performance of the apparatus inside the switchgear.
The data shown are a summary of software model
simulations and real tests.
HR Terminal
VR Terminal
One circuit-breaker in the column One circuit-breaker in the column
SACE Emax 2 E1.2 L Circuit-breaker
Switchgear dimensions 2200x400x600 (HxLxD)
Environment temperature
IP
Environment temperature
Iu
Connection Compartment 35 °C
[mm]
45 °C
55 °C
35 °C
45 °C
55 °C
630
2x40x5
1
630
630
630
630
630
630
800
2x50x5
1
800
800
800
800
800
800
2x50x10
1
1000
1000
950
1000
1000
1000
1250
1205
1050
IP31
6
Compartment 2
1000
1SDC200574F001
2x50x8
Compartment 1
2x50x10
1
2x50x8
1
1250
1125
955
1250
Performances with EF, SHR and F terminals can be compared, with the same connection sections, to the performances of circuit-breaker with HR terminal.
Performances with ES terminals can be compared to the VR terminals.
Performances with FC CuAl terminals, with cables in the prescribed sections, can be compared to HR performances
6/22 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap06.indd 22
15/04/2013 09:53:56
Dimensions
Fixed circuit-breaker
7/2
E1.2
7/4
E2.2
7/8
E4.2
7/12
E6.2
7/14
Withdrawable circuit-breaker
7/18
E1.2
7/20
E2.2
7/24
E4.2
7/28
E6.2
7/30
7
ABB Catalogue | 1SDC200023D0201 | 7/1
Emax2_cap07.indd 1
15/04/2013 17:55:42
Dimensions
Fixed circuit-breaker
E1.2
E2.2 - E4.2 - E6.2
A
A
B
Y
B
40
C
C
Y
136,5
296
X
168.5
Y
6
12
Y
1SDC200581F001
x
1SDC200580F001
x
273
331 X
A
B
[mm]
4p
3p
3p
4p
E1.2
280
210
103.6
103.6
E2.2
366
276
138
138
E4.2
510
384
192
192
E6.2
888
762
318
444
-
-
444
E6.2/f 1014
C
7
Compartment door drilling
E1.2
E2.2 - E4.2 - E6.2
306
244
Y
226
100
X
37
X
100
100
Y
Ø4 n°6 holes
Y
1SDC200582F001
348
X
100
X
100
112
224
153
179
Y
158
Ø5 n°8 holes
E1.2
E2.2 - E4.2 - E6.2
12.5
1SDC200583F001
E1.2
2
3
130 MIN
A MIN
(48)
A MIN
164 MAX
A MAX
(88)
A MAX
Standard Ronis/Profalux Kirk
Castell
A MIN
[mm] 49.5
63.5
63.5
83.5
A MAX
[mm] 83.5
97.5
97.5
117.5
E2.2-E4.2-E6.2 Standard Ronis/Profalux Kirk
Castell
A MIN
[mm] 31
41.5
45.5
-
A MAX
[mm] 71
81.5
85.5
-
7/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 2
15/04/2013 17:55:43
Dimensions of the compartment
D
D
A
B
[mm]
3p
4p
E1.2
250
E2.2
400
E4.2
500
E6.2
900
1SDC200584F001
B
1SDC200571F001
C
C
A
B
E6.2/f -
C
D
322
382.5 *
130
490
500
221
600
500
221
1000
500
221
1200
500
221
* 332.5 for voltages d 440V AC
A
7
Floor fixing
Y
A
=
Ø 10.5
X C
X
1SDC200585F001
=
Y
A (III)
A (IV)
B
117
187
117
117
80
E2.2
154
244
154
154
150
E4.2
208
334
208
208
150
E6.2
460
460
334
460
150
586
-
460
150
3p
4p
Earthing device E2.2 - E4.2 - E6.2
52.5
39.75
Ø 10 MAX
X
35
X
R10
Y
Ø 5.5 - M5
B
17.5
1SDC200586F001
1)
[mm]
3p
4p
A
192.5
262.5
B
70
140
1SDC200587F001
8
122.5
E1.2
4p
61.25
Y
245
C
3p
E6.2/f -
Wall fixing (only for E1.2)
A
B
[mm]
M4x8 screws supplied
Tightening torque 1.5Nm
1) for fixing with rear terminals
ABB Catalogue | 1SDC200023D0201 | 7/3
Emax2_cap07.indd 3
15/04/2013 17:55:43
Dimensions
Fixed circuit-breaker - E1.2
Front terminals – F
129
3
280 (IV)
210 (III)
24
10
4
105
10
Y
1
10
1
134
102
X
291
X
268
X
5
Y
25
X
204
MIN. 130 - MAX. 164 WITH FLANGE
170 WITHOUT FLANGE
50
178
70
70
184
70
Extended front terminals – EF
129
70
7
29.5
70
70
Y
4
7
~100
15
1
2
~100
95
150
150
173
20
X
X
134
102
20
291
204
2
X
X
268
20
5
Y
6
105
210 (III)
178
280 (IV)
184
25
2
MIN. 130 - MAX. 164 WITH FLANGE
170 WITHOUT FLANGE
Ø 11
15
14
12.5
25
95
= 44 =
20.5
1
2
3
4
Front terminals for flat connection
Extended front terminals
To be supplied by the customer
Tightening torque 18Nm
5
6
7
Door position - Ref. page 7/2
Obligatory phase separators 100mm
Obligatory insulating plate to be supplied by
the customer
1SDC200594F001
Key
7/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 4
15/04/2013 17:55:44
Orientable rear terminals - HR/VR
280 (IV)
210 (III)
105
7.5
Y
7.5
23.5
1.5
12.5
138.5
277
x
x
295
55
R 5.5
25.5
18
Y
73
= 44 =
Terminals HR
184
3
59
7
12.5
129
1
70
70
127.25
102
x
254.5
15
N
4
1
Y
R 5.5
x
204
1
70
Y
L1
L3
L2
MIN. 130 - MAX. 164
WITH FLANGE
170 WITHOUT FLANGE
178
Terminals VR
184
70
59
129
2
70
12.5
3
70
3.75
2
15
2
Y
2
106
x
x
x
212
204
x
x
Y
MIN. 130 - MAX. 164
WITH FLANGE
170 WITHOUT FLANGE
4
178
70
3.75
70
4
70
1
2
3
4
Horizontal orientable terminals HR
Vertical orientable terminals VR
Tightening torque 20Nm
Door position - Ref. page 7/2
1SDC200595F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/5
Emax2_cap07.indd 5
15/04/2013 17:55:45
Dimensions
Fixed circuit-breaker - E1.2
Splayed extended front terminals - ES
3-pole version
116
116
23
Y
~200
1
230
258.5
55
56
100
X
X
5
Y
105
210
7
= 90 =
31.5
45
= 90 =
15
31.5
45
22.5
15
22.5
20
20
171.5
171.5
4-pole version
116
116
129
116
40.5
23
1
Y
15
1
2
~200
~200
230
1
2
258.5
56
134
102
100
X
100
X
X
204
X
268
3
5
90
4
Y
105
MIN. 130 - MAX. 164
WITH FLANGE
170 WITHOUT FLANGE
178
280
= 90 =
22.5
= 90 =
31.5
45
15
31.5
45
31.5
45
22.5
20
= 90 =
15
171.5
31.5
45
15
22.5
20
20
= 90 =
15
22.5
171.5
20
171.5
171.5
1
2
3
Splayed extended front terminals
Tightening torque 18Nm
Door position - Ref. page 7/2
4
5
Obligatory phase separators 200mm
Obligatory insulating plate to be supplied by the
customer
1SDC200596F001
Key
7/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 6
15/04/2013 17:55:46
Front terminals for cables – FcCuAl
184
280 (IV)
210 (III)
5
105
129
2
59.25
3
20
Y
1
27.75
9
95
134
268
X
166
147.5
20
20
191.5
1
202
102
291
X
404
204
X
26
X
150
9
95
4
Y
70
70
101
70
MIN. 130 - MAX. 164 WITH FLANGE
170 WITHOUT FLANGE
178
= 58 =
1
7
70
28
38
13
16.75
Ø 21.5
30.4
31
73
31.5
31.6
87
25
1
2
3
Front terminals for cables FC CU AL
Tightening torque 43Nm
Tightening torque 18Nm
4
5
Door position - Ref. page 7/2
Obligatory insulating plate to be
supplied by the customer
1SDC200597F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/7
Emax2_cap07.indd 7
15/04/2013 17:55:47
Dimensions
Fixed circuit-breaker - E2.2
Orientable rear terminals - HR/VR
E2.2 B/N/S/H 2000A
E2.2 N/S/H 2500A
366 (IV)
270
276 (III)
9
138
40
35 - 2000A
47 - 2500A
35
9
15
2
4
10
331
325
8
168.5
35 - 2000A
47 - 2500A
47
40
15
2
4
10
124
114
114
93
98
98
33
114
M5
98
24
6
12
7
5
84
48 MIN
88 MAX
5
6
7
1
150
3
6
5
6
23
E2.2 B/N/S/H 2000A
7
1 3
2000A
Ø 13
35
90
90
90
10
12
33
N
45
60
90
2
50
L1
L2
90
L3
90
10
N
L1
L2
L3
E2.2 N/S/H 2500A
1 3
2500A
3 4
90
90
30
Ø 13
35
90
10
12
N
33
45
60
4
L1
90
L2
90
L3
90
10
60
250
N
L1
L2
L3
1
2
3
Horizontal terminals 2000A
Vertical terminals 2000A
Horizontal terminals 2500A
4
5
6
Vertical terminals 2500A
Tightening torque 2000A 8.6Nm
Tightening torque 2500A 8.6Nm
7
8
9
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
Insulating wall
1SDC200598F001
Key
7/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 8
15/04/2013 17:55:48
Front terminals – F
366 (IV)
270
22
276 (III)
20
138
4
15
Y
1
1
40
3
451
X
X
331
X
325 X
168.5
2
3
5
M5
2
39
6
12
Y
84
15
48 MIN
88 MAX
20
150
23
Lower front terminals – F
Upper front terminals – F
7
1
2
230
15
167
Ø 13
15
Ø 13
35 60
35
60
1
2
3
Upper front terminals
Lower front terminals
Tightening torque 8.6Nm
4
5
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
1SDC200599F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/9
Emax2_cap07.indd 9
15/04/2013 17:55:49
Dimensions
Fixed circuit-breaker - E2.2
Horizontal spread terminals – SHR
E2.2 B/N/S/H 2000A
E2.2 N/S/H 2500A
366 (IV)
276 (III)
270
138
57
9
Y
9
3
4
69
1
2
40
10
10
325
X
X
331
X
X
X
124
X
114
8
168.5
M5
93
98
5
6
24
12
Y
6
7
84
48 MIN
88 MAX
150
23
=
E2.2 B/N/S/H 2000A
7
1
= 60 =
10
35
15
55
60
100
10
1 3
1
Y
L1
L3
L2
130
2 4
2
130
Y
III
= 45 =
35
130
2 4
67
130
90
Y
1 3
15
55
67
IV
= 60 =
Y
L2
L1
N
2
L3
= 45 =
E2.2 N/S/H 2500A
3
= 60 =
30
35
10
15
55
67
130
2 4
130
Y
1 3
60
100
4
= 60 =
L1
130
2 4
30
35
3
Y
III
L3
L2
90
130
Y
10
1 3
4
15
55
67
IV
N
= 60 =
L1
Y
L2
L3
= 60 =
1
2
3
Side horizontal splayed terminals 2000A
Central horizontal splayed terminals 2000A
Side horizontal splayed terminals 2500A
4
5
6
Central horizontal splayed terminals 2500A
Tightening torque 2000A 8.6Nm
Tightening torque 2500A 8.6Nm
7
8
9
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
Insulating wall
1SDC200600F001
Key
7/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 10
15/04/2013 17:55:50
Vertical spread terminals – SVR
366 (IV)
270
276 (III)
57
69
138
Y
1
40
X
X
331
325
X
X
6
168.5
X
194
X
194
M5
58
58
24
12
2
Y
6
3
5
48 MIN
88 MAX
4
84
150
23
E2.2 B/N/S/H 2000A
7
= 60 =
1
10
35
90
90
15
1
90
10
Y
55
67
60
N
100
Y
L2
L1
1
L3
= 45 =
E2.2 N/S/H 2500A
2
30
= 60 =
10
35
90
90
15
55
100
10
67
N
60
L1
2
90
Y
Y
L2
2
L3
= 60 =
1
2
3
Vertical splayed terminals 2000A
Vertical splayed terminals 2500A
Tightening torque 2000A 8.6Nm
4
5
6
Tightening torque 2500A 8.6Nm
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
1SDC200601F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/11
Emax2_cap07.indd 11
15/04/2013 17:55:51
Dimensions
Fixed circuit-breaker - E4.2
Orientable rear terminals - HR/VR
E4.2 N/S/H/V 3200A
E4.2 N/S/H/V 4000A
510 (IV)
270
276
Y
40
4
35
325 X
X
X
8
2
4
134
X
X
X 114
9
2
4
10
X
X
X
35 - 3200A
47 - 4000A
114
X
X 114
98
88
98
98
24
Y
6
0A
0A
M5
168.5
12
9
9
20
331 X
47
35 - 3200A
47 - 4000A
9
138
192
7
384 (III)
84
48 MIN
88 MAX
150
23
5
6
7
1
5
1
3
5
6
5
6
E4.2 N/S/H/V 3200A
7
1 3
N
L2
L1
126
126
Y
L3
126
1
35
20
12
Ø 13
N
33
L2
L1
L3
45
2
1 2
2
Y
= 80 =
126
126
Y
126
20
= 70 =
Y
N
L2
L1
L3
Y
E4.2 N/S/H/V 4000A
1 3
N
L2
L1
126
126
Y
L3
126
3
35
50
12
10
Ø 13
33
N
L3
Y
4
3 4
L2
L1
45
= 80 =
4
Y
126
126
126
10
10
= 80 =
Y
1 3
N
L1
L2
L3
1
2
3
Horizontal terminals 3200A
Vertical terminals 3200A
Horizontal terminals 4000A
4
5
6
Vertical terminals 4000A
Tightening torque 3200A 20Nm
Tightening torque 4000A 20Nm
7
8
9
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
Insulating wall
1SDC200602F001
Key
7/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 12
15/04/2013 17:55:53
Front terminals – F
510 (IV)
4
276
138
270
22
15
Y
20
1
40
1
3
X
331
445.5
X
325
X
X
5
168.5
3
2
3
MØ 5
6
24
33.5
12
Y
2
15
192
48 MIN
88 MAX
384 (III)
84
20
150
23
8
Lower front terminals
Upper front terminals
7
1
2
171.5
240
15
15
Ø 13
Ø 13
35 80
35 80
1
2
3
Upper front terminals
Lower front terminals
Tightening torque 20Nm
4
5
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
1SDC200603F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/13
Emax2_cap07.indd 13
15/04/2013 17:55:54
Dimensions
Fixed circuit-breaker - E6.2
Horizontal rear terminals – HR
E6.2 H/V/X 5000A
E6.2 H/V/X 6300A
888 (IV)
762 (III)
270
444 (IV)
40
51
51
7
318 (III)
Y
7
20
331 X
325
X
X
X
6
168.5
Y
6
12
138
X
134
X
114
M5
24
98
88
1
3
5
276
10
84
48 MIN
88 MAX
150
2
4
23
E6.2 H/V/X 5000A
7
252
1 2
1
35
20
12
III
45
189
1
63
L2
252
1 2
= 80 =
252
Y
L1
33
13
Y
L3
252
Y
63
= 70 =
IV
Y
L1
N
L2
L3
E6.2 H/V/X 6300A
252
1 2
2
35
50
12
Y
III
10
13
45
189
L2
252
1 2
10
= 80 =
63
2
Y
L1
33
252
L3
252
Y
63
= 80 =
IV
Y
N
L1
L2
L3
1
2
3
4
Horizontal terminals 5000A
Horizontal terminals 6300A
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
5
6
7
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
Insulating wall
1SDC200604F001
Key
7/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 14
15/04/2013 17:55:55
Vertical rear terminals – VR
E6.2 H/V/X 5000...6300A
888 (IV)
762 (III)
444 (IV)
40
51
318 (III)
1
2
Y
325
X
X
331
168.5
12
Y
6
X
6
98
5
9
114
M5
24
138
276
X
3
4
84
48 MIN
88 MAX
150
23
E6.2 H/V/X 5000A
7
1
1
35
252
252
3
20
Y
1
63
12
33
III
45
Y
L1
1
Ø 13
= 80 =
189
L2
3
= 70 =
L3
252
252
63
Y
IV
Y
L1
N
L2
L3
E6.2 H/V/X 6300A
2
2
35
252
4
50
Y
63
2
10
12
33
Ø 13
252
III
2
10
= 80 =
Y
L1
45
189
L2
252
63
Y
4
= 80 =
L3
252
IV
Y
N
L1
L2
L3
1
2
3
4
Vertical terminals 5000A
Vertical terminals 6300A
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
5
6
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
1SDC200605F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/15
Emax2_cap07.indd 15
15/04/2013 17:55:56
Dimensions
Fixed circuit-breaker - E6.2
Orientable rear terminals - HR/VR full size
E6.2 H/V/X 5000A
E6.2 H/V/X 6300A
1014
444
270
276
40
51
15
51
138
9
Y
20
331 X
325
X
X
X
8
168.5
X
134
X 114
12
6
1
24
11
7
84
48 MIN
88 MAX
9
10
X
X
X
114
X
9
2
4
X 114
M5
98
88
Y
51
15
51
9
2
4
5
150
7
98
5
6
8
3
6
98
5
6
23
E6.2 H/V/X 5000A
7
1 2
35
252
1 3
20
252
252
Y
63
12
33
Y
45
N
L1
L2
L3
Ø 13
= 80 =
= 70 =
252
252
2
252
Y
63
Y
N
L1
L2
L3
E6.2 H/V/X 6300A
35
252
Y
63
10
Y
33
N
L1
L2
L3
45
4
10
= 80 =
252
50
12
Ø 13
252
1 3
3 4
252
252
252
Y
63
= 80 =
Y
N
L1
L2
L3
1
2
3
Horizontal terminals 5000A
Vertical terminals 5000A
Horizontal terminals 6300A
4
5
6
Vertical terminals 6300A
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
7
8
9
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
Insulating wall
1SDC200606F001
Key
7/16 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 16
15/04/2013 17:55:57
Front terminals – F
1014 (IV FS)
888 (IV)
444 (IV/IV FS)
318 (III)
15
4
Y
270
26
20
1
1
40
3
445.5
X
X
331
325
X
X
6
15
33.5
Y
12
M5
2
2
24
138
84
276
48 MIN
88 MAX
762 (III)
8
2
3
5
168.5
20
150
23
Lower front terminal
Upper front terminals
7
1
2
240
Ø 13
171.5
15
35
252
80
35
252
189
Y
L1
L2
Y
80
252
252
252
63
15
Ø 13
Y
L3
N
L1
3-pole
Y
252
252
63
63
Y
L2
4-pole
L3
N
L1
Y
L2
L3
4-pole full size
1
2
3
Upper front terminals
Lower front terminals
Tightening torque 20Nm
4
5
Door position - Ref. page 7/2
Earthing device - Ref. page 7/3
1SDC200607F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/17
Emax2_cap07.indd 17
15/04/2013 17:55:58
Dimensions
Withdrawable circuit-breaker
E1.2
E2.2 - E4.2 - E6.2
A
A
B
B
C
C
Y
x
363.5
159.5
425
X
X
1SDC200588F001
x
1SDC200589F001
343
Y
185.5
A
B
[mm]
4p
3p
3p
4p
E1.2
348
278
155.5
155.5
E2.2
407
317
158.5
158.5
E4.2
551
425
212.5
212.5
E6.2
929
803
338.5
464.5
-
-
464.5
E6.2/f 1055
C
Y
Y
7
Compartment door drilling
E1.2
E2.2 - E4.2 - E6.2
306
244
Y
226
Y
179
100
X
X
X
100
1SDC200582F001
37
100
X
348
100
112
224
153
100
Y
Ø4 n°6 holes
Y
158
Ø5 n°8 holes
Distance from connected to isolated position
E1.2
E2.2 - E4.2 - E6.2
C
305
12.5
C
E1.2
3
40
3
251
275.5
2
B
75
B
1SDC200590F001
47
Standard Ronis/Profalux Kirk
Castell
B
[mm] 44.5
55
55
85
C
[mm] 36
46.5
46.5
76.5
E2.2-E4.2-E6.2 Standard Ronis/Profalux Kirk
Castell
C
[mm] 17.5
28
32
-
B
[mm] 24
34.5
38.5
-
B refers to KLC; C refers to KLP
7/18 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 18
15/04/2013 17:55:59
Dimensions of the compartment
D
D
A
B
[mm]
3p
4p
E1.2
280
E2.2
400
E4.2
500
600
500
355
E6.2
900
1000
500
355
1200
500
355
1SDC200570F001
B
1SDC200591F001
C
C
A
B
E6.2/f -
C
D
350
440*
252
490
500
355
* 390 for voltages d 440V AC
A
7
Floor fixing
A
E (III)
E (IV)
Y
A (III)
X
50
B (III)
75
F (III)
X
Ø 10
A (IV)
Y
B (IV)
Earthing device E2.2 - E4.2 - E6.2
=
C
=
1SDC200592F001
Y
D (IV)
D (III)
1SDC200593F001
C
3p
4p
3p
4p
E1.2
80
150
80
80
E2.2
75
170
75
80
E4.2
100
225
100
E6.2
363
375
237
375
-
E6.2/f -
D
E
F
3p
4p
3p
4p
100
-
-
-
-
-
150
270
360
135
135
-
100
150
378
504
189
189
-
375
150
756
882
315
441
63
375
150
441
0
1008
Fixing on support sheet (only for E1.2)
Y
Ø10 MAX
M4x8 screws supplied
Tightening torque 1.5Nm
B
[mm]
100
Ø 9
Y
80 (III)
80
150 (IV)
ABB Catalogue | 1SDC200023D0201 | 7/19
Emax2_cap07.indd 19
15/04/2013 17:55:59
Dimensions
Withdrawable circuit-breaker - E1.2
Rear orientable terminals - HR/VR
348 (IV)
8
278 (III)
Y
155.5
2
3
363.5
25
15
Ø 11
343
X
X
12.5
33
39
159.5
= 44 =
= 44 =
Y
Terminals HR
271
251
10
7
7
2
29
2
15
70
7
236.5
X
4
X
2
Y
213
Y
2
57.5
70
70
N
L1
L2
L3
2
3
53
5
49
100
15
42
Terminals VR
271
251
10
7
2
29
3
7
236.5
X
X
70
70
Y
70
15
198
N
L1
Y
L2
3
L3
60.5
57.5
5
49
100
15
42
3
4
2
3
4
Horizontal rear terminals
Vertical rear terminals
Tightening torque 12 Nm
5 Door position - Ref. page 7/18
7 Rear segregation for rear terminals
10 Isolating distance
1SDC200608F001
Key
7/20 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 20
15/04/2013 17:56:00
Extended front terminals – EF
348 (IV)
271
278 (III)
8
Y
15
251
155.5
8
15
1
10
Y
2
III - 342
IV - 456
20
202
343
1
115
Ø 6.5
236.5
X
X
50
30
239.5
363.5
8
193.5
8
X
X
III - 206
IV - 276
X
99.5
363.5
199
230
X
460
109.5
159.5
103
57.5
5
4
49
Y
6
42
6
4
100
Y
III - 219
IV - 289
6
15
203
1
25
1
12.5
12.5
Ø 11
= 44
12.5
= 44 =
73
25
7
15
73
200
12.5
Rear terminals for cables – FcCuAl
348 (IV)
278 (III)
271
155.5
10
Y
343
x
251
2
17.5
x
363.5
236.5
2
70
81.5
x
95
2
x
10
7
159.5
2
70
7.5
Y
57.5
Y
Y
3
5
49
N
L1
L2
L3
100
15
7
42
67.5
2
17.5
10
17.5
37.5
110
37.5
17.5
Ø 14.5
1
2
3
Front terminals
Rear terminals for cables
Tightening torque 48 Nm
4
5
6
Tightening torque 12 Nm
Door position - Ref. page 7/18
Rear segregation for front terminals
7 Rear segregation for rear terminals
8 Insulating protection
10 Isolating distance
1SDC200609F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/21
Emax2_cap07.indd 21
15/04/2013 17:56:01
Dimensions
Withdrawable circuit-breaker - E1.2
Front spread terminals - ES
3-pole version
114
271
5
114
22
3
15
2
Y
15
251
1
15
8
5
1
2
324
324.5
X
363.5
343
X
236.5
X
X
159.5
57.5
4
6
49
42
Y
6
100
15
155.5
188
278
7
1
1
= 88 =
45
= 88 =
22.5
Ø 13
= 88 =
1
45
22.5
Ø 13
20
15
45
22.5
Ø 13
20
20
116.5
132
4-pole version
114
114
271
5
114
22
3
15
2
Y
15
251
1
15
8
5
1
2
324.5
324
343
X
X
363.5
236.5
X
X
159.5
57.5
= 88 =
45
4
Y
49
42
6
100
15
155.5
188
348
= 88 =
1
15
45
1
Ø 13
1
= 88 =
45
= 88 =
22.5
Ø 13
15
45
22.5
Ø 13
Ø 13
20
20
= 88 =
1
45
22.5
22.5
20
20
116.5
116.5
132
132
1
2
3
Splayed terminal
Tightening torque 40 Nm
Front terminal
4
5
Door position - Ref. page 7/18
Insulating protection (refer to front terminals
page 7/21
6
8
Rear segregation for front terminals
Isolating distance
1SDC200610F001
Key
7/22 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 22
15/04/2013 17:56:03
Horizontal rear spread terminals – SHR
348 (IV)
278 (III)
Y
155.5
= 60 =
1
60
2
15
42.5
12.5
25
25
343
x
363.5
x
36
2.5
39
83
25
159.5
15
19.5
9.5
83
28.75
25
20
Ø 11
25
25
= 44 =
Y
3-pole version
271
7
90
3
1 2
251
2
7
15
90
236.5
x
x
243
90
1
Y
5
1
121.5
57.5
Y
L1
L2
L3
100
49
4
5
15
42
4-pole version
271
7
90
3
1 2
251
2
15
90
90
10
5
236.5
x
x
90
2
Y
2
243
121.5
Y
N
L1
L2
L3
57.5
100
49
4
15
5
42
1
2
3
Splayed rear terminals for 3-pole version
Splayed rear terminals for 4-pole version
Tightening torque 18 Nm
4
5
7
Door position - Ref. page 7/18
Rear segregation of rear terminals
Isolating distance
1SDC200611F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/23
Emax2_cap07.indd 23
15/04/2013 17:56:04
Dimensions
Withdrawable circuit-breaker - E2.2
Rear orientable terminals - HR/VR
E2.2 B/N/S/H 2000A
E2.2 N/S/H 2500A
383
317 (III)
47
7
158.5
13
14
15
14
407 (IV)
1
Y
12
47
47
10
425
X
X
4
351
X
X
124
X
X
1
2
4
430
114
47
10
X
X
114
X
X
2
4
430
114
8
185.5
3
118
Ø 5.45
123
123
123
34
Y
75
150
34
5
6
74.5
5
351
366
7
13
1
10
3
6
5
6
E2.2 B/N/S/H 2000A
331 (III) / 421(IV)
35
12
Ø 13
90
90
4
Y
45
N
= 60 =
1 2
90
14
33
3
165.5
1 3
10
Y
L2
L1
L3
3 4
= 50 =
2
90
90
14
90
Y
N
Y
L2
L1
L3
E2.2 N/S/H 2500A
331 (III) / 421(IV)
165.5
1 3
35
Ø 13
90
2
1
90
Y
14
30
12
90
10
33
N
45
4
= 60 =
= 60 =
90
90
L3
90
Y
14
3 4
Y
L2
L1
N
L1
Y
L2
L3
1
2
3
4
Horizontal terminals 2000A
Vertical terminals 2000A
Horizontal terminals 2500A
Vertical terminals 2500A
5
6
7
8
Tightening torque 2000A 8.6Nm
Tightening torque 2500A 8.6Nm
Door position - Ref. page 7/19
Earthing device
12
13
14
15
Mobile part
Fixed part
Segregation (where envisaged)
Distance from connected for testing to isolated
1SDC200612F001
Key
7/24 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 24
15/04/2013 17:56:06
Front terminals – F
34
407 (IV)
317 (III)
158.5
20
15
Y
11
1
4
10
3
9
425
521
X
351
X
X
X
X
X
3
5
185.5
Ø 5.45
13
Y
15
34
2
50
150
225
224.5
34
215
141
20
155
Upper front terminals
7
1
1
2
1
2
264
15
Ø 13
90
90
90
Y
35 60
N
L1
Y
L2
L3
Lower front terminals
2
203
15
Ø 13
35
60
1
2
3
4
Upper front terminals
Lower front terminals
Tightening torque 8.6Nm
Door position - Ref. page 7/19
5
9
10
11
Earthing device
Mobile part
Fixed part
Distance from connected for testing to isolated
1SDC200613F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/25
Emax2_cap07.indd 25
15/04/2013 17:56:06
Dimensions
Withdrawable circuit-breaker - E2.2
Horizontal rear spread terminals – SHR
E2.2 B/N/S/H 2000A
14
407 (IV)
13
E2.2 N/S/H 2500A
317 (III)
12
14
383
158.5
14
7
Y
1
2
69
10
X
425
X
351
X
X
10
X
124
8
185.5
34
Ø 5.45
3
4
69
X
114
123
118
Y
150
215
141
5
202
225
15
202
6
351
E2.2 B/N/S/H 2000A
7
1
= 60 =
10
35
15
331
55
1
165.5
67
130
2 4
130
1 3
Y
60
100
= 45 =
Y
L2
L1
L3
14
421
165.5
35
2
10
2 4
15
55
67
Y
L2
L1
L3
407 (IV)
13
= 45 =
1 3
130
Y
N
= 60 =
90
130
2
14
E2.2 N/S/H 2500A
3
= 60 =
30
35
3
10
15
331
55
165.5
67
130
2 4
130
1 3
Y
60
100
= 60 =
Y
L2
L1
L3
14
421
4
165.5
30
35
2 4
10
90
130
15
55
67
= 60 =
N
13
= 60 =
1 3
130
Y
L1
Y
L2
407 (IV)
L3
4
14
331
1
2
3
4
Side horizontal splayed terminals 2000A
Central horizontal splayed terminals 2000A
Side horizontal splayed terminals 2500A
Central horizontal splayed terminals 2500A
5
6
7
8
Tightening torque 2000A 8.6Nm
Tightening torque 2500A 8.6Nm
Door position - Ref. page 7/19
Earthing device
12 Mobile part
13 Fixed part
14 Segregation (where envisaged)
1SDC200614F001
Key
7/26 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 26
15/04/2013 17:56:08
Vertical rear spread terminals – SVR
E2.2 B/N/S/H 2000A
E2.2 N/S/H 2500A
11
407 (IV)
317 (III)
10
158.5
13
383
5
12
12
Y
1
2
69
425
X
X
430
X
X
351
X
X
194
6
185.5
Ø 5.45
34
83
Y
150
13
215
141
3 4
202
215
225
34
224.5
351
E2.2 B/N/S/H 2000A
7
1
= 60 =
1
10
35
12
15
55
90
90
Y
67
Y
L2
L1
N
60
100
1
90
L3
= 45 =
E2.2 N/S/H 2500A
2
= 60 =
30
35
331(III)/421(IV)
12
15
55
2
165.5
10
90
90
2
90
Y
67
N
L1
Y
L2
L3
60
100
= 60 =
1
2
3
4
Vertical splayed terminals 2000A
Vertical splayed terminals 2500A
Tightening torque 2000A 8.6Nm
Tightening torque 2500A 8.6Nm
5
6
10
11
Door position - Ref. page 7/19
Earthing device
Mobile part
Fixed part
12 Segregation (where envisaged)
13 Distance from connected for testing to
isolated
1SDC200615F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/27
Emax2_cap07.indd 27
15/04/2013 17:56:09
Dimensions
Withdrawable circuit-breaker - E4.2
Rear orientable terminals - HR/VR
E4.2 N/S/H 3200A
383
551 (IV)
212.5
12
15
14
425 (III)
13
E4.2 N/S/H 4000A
E4.2 V 2000...4000A
14
7
47
425
47
Y
351 X
X
X
47
2
4
2
4
47
20
X
X
X
154
430
134
X
X
430
184
X
X
4
184
8
185.5
103
Ø 5.45
113
113
5
6
5
6
113
34
Y
13
10
75
1
150
351
366
34
74.5
3
6
5
E4.2 N/S/H 3200A
7
439 (III) / 565 (IV)
1 3
1 2
35
20
14
12
33
219.5
126
126
Y
126
1
2
Y
45
N
L1
L3
L2
Ø 13
= 80 =
2
= 70 =
126
126
126
Y
14
Y
4
N
L1
L2
L3
E4.2 N/S/H 4000A
E4.2 V 2000...4000A
439 (III) / 565 (IV)
1 3
35
50
12
3 4
Ø 13
14
10
33
219.5
126
126
Y
126
3
4
Y
45
10
= 80 =
4
= 80 =
N
L1
L2
L3
N
L1
L2
L3
126
126
Y
126
14
Y
N
L1
L2
L3
1
2
3
4
Horizontal terminals 3200A
Vertical terminals 3200A
Horizontal terminals 4000A
Vertical terminals 4000A
5
6
7
8
Tightening torque 3200A 20Nm
Tightening torque 4000A 20Nm
Door position - Ref. page 7/19
Earthing device
12
13
14
15
Mobile part
Fixed part
Segregation (where envisaged)
Distance from connected for testing to isolated
1SDC200616F001
Key
7/28 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 28
15/04/2013 17:56:11
Front terminals – F
551 (IV)
425 (III)
Y
212.5
15
383
4
1
20
11
3
425
X
521
X
X
351
X
3
4
X
X
5
185.5
Ø 5.45
2
10
Y
15
13
10
45
9
75
150
291
34
20
34
74.5
380
Upper front terminals
7
1
1
269
15
Ø 13
126
35
126
126
Y
80
2
Y
N
L1
L2
L3
Lower front terminals
2
2
198
15
Ø 13
35
80
1
2
3
Upper front terminals
Lower front terminals
Tightening torque 20Nm
4
5
9
Door position - Ref. page 7/19
Earthing device
Mobile part
10 Fixed part
11 Distance from connected for testing to isolated
1SDC200617F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/29
Emax2_cap07.indd 29
15/04/2013 17:56:12
Dimensions
Withdrawable circuit-breaker - E6.2
Horizontal rear terminals – HR
E6.2 H/V 5000A
E6.2 H/V 6300A
E6.2 X 5000...6300A
929 (IV)
464.5
(IV)
383
803 (III)
11
10
12
338.5 (III)
Y
47
47
10
20
425
X
X
6
X
X
X
154
X 184
Ø 5.45
185.5
Y
113
103
5
34
10
75
150
351
366
1
2
3
4
E6.2 H/V 5000A
7
817
1 2
35
1
252
20
12
45
L1
L2
189
Ø 13
252
L3
252
Y
12
= 70 =
Y
943
1 2
= 80 =
1
252
63
III
33
Y
12
IV
N
Y
L1
63
L2
L3
E6.2 H/V 6300A
E6.2 X 5000...6300A
2
35
252
Y
12
50
2
817
1 2
252
63
10
12
III
33
45
= 80 =
= 80 =
189
Y
252
L3
252
Y
12
IV
L2
943
1 2
10
Ø 13
L1
N
L1
Y
63
L2
L3
1
2
3
4
Horizontal terminals 5000A
Horizontal terminals 6300A
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
5 Door position - Ref. page 7/19
6 Earthing device
10 Mobile part
11 Fixed part
12 Segregation (where envisaged)
13 Distance from connected for testing to isolated
1SDC200618F001
Key
7/30 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 30
15/04/2013 17:56:13
Vertical rear terminals – VR
E6.2 H/V 5000A
E6.2 H/V 6300A
E6.2 X 5000...6300A
929 (IV)
464.5 (IV)
383
803 (III)
11
10
Y
383
12
5
338.5 (III)
X
425
X
6
X
12
5
1
2
47
X
47
6
X
134
X
1
2
184
185.5
113
113
Y
34
10
75
150
75
3
4
351
A
366
34
10
150
351
366
3
4
E6.2 H/V 5000A
7
1
1
35
33
817
252
3
20
12
III
45
= 80 =
L1
= 70 =
1
252
12
L2 Y
L3
943
1
Ø 13
Y
63
189
252
3
252
IV
N
Y
L1
12
63
Y
L2
L3
E6.2 H/V 6300A
E6.2 X 5000...6300A
817
2
2
35
50
12
33
252
4
10
2
252
63
Y
12
III
L1
45
L2
Y
L3
943
Ø 13
= 80 =
10
= 80 =
2
189
252
4
252
12
63
Y
IV
N
L1
Y
L2
L3
1
2
3
4
Vertical terminals 5000A
Vertical terminals 6300A
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
5 Door position - Ref. page 7/19
6 Earthing device
10 Mobile part
11 Fixed part
12 Segregation (where envisaged)
13 Distance from connected for testing to isolated
1SDC200619F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/31
Emax2_cap07.indd 31
15/04/2013 17:56:14
Dimensions
Withdrawable circuit-breaker - E6.2
Rear orientable terminals - HR/VR full size
E6.2 H/V 5000A
12
E6.2 H/V 6300A
E6.2 X 5000...6300A
383
1055
7
464.5
Y
14
47
425
47
20
13
8
X
X
X
X
X
154
X
42
184
Ø 5.45
185.5
113
103
Y
11
34
10
75
150
351
366
1
3
5
6
E6.2 H/V 5000A
7
1 3
1 2
1069
252
35
33
252
14
20
12
45
252
63
Y
N
Y
L1
L2
L3
Ø 13
= 80 =
= 70 =
2
1069
252
252
14
252
Y
63
N
Y
L1
L2
L3
E6.2 H/V 6300A
E6.2 X 5000...6300A
1 3
3 4
35
50
12
33
Ø 13
1069
252
10
45
Y
Y
L1
4
= 80 =
252
63
N
10
= 80 =
252
14
L2
L3
1069
252
252
252
Y
63
14
N
L1
Y
L2
L3
1
2
3
4
Horizontal terminals 5000A
Vertical terminals 5000A
Horizontal terminals 6300A
Vertical terminals 6300A
5
6
7
8
Tightening torque 5000A 20Nm
Tightening torque 6300A 20Nm
Door position - Ref. page 7/19
Earthing device
12 Mobile part
13 Fixed part
14 Segregation (where envisaged)
1SDC200620F001
Key
7/32 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap07.indd 32
15/04/2013 17:56:15
Front terminals – F
1055 (IV FS)
929 (IV)
803 (III)
338.5 (III)
383
276
15
Y
4
138
11
1
20
1
3
521
X
425
X
351 X
X
X
185.5
Y
15
10
75
464.5 (IV/IV FS)
20
150
5
X
Ø 5.45
3
45
9
10
2
34
2
13
291
74.5
380
34
Upper front terminals
Lower front terminals
1
2
269
198
Ø 13
15
35
80
35
189
63
252
L2
Y
252
80
252
252
63
Y
Y
L1
15
Ø 13
252
252
7
Y
Y
L3
N
3-pole
L1
L2
4-pole
L3
N
L1
Y
252
63
L2
L3
4-pole full size
1
2
3
Upper front terminals
Lower front terminals
Tightening torque 20Nm
4
5
9
Door position - Ref. page 7/19
Earthing device
Mobile part
10 Fixed part
11 Distance from connected for testing to
isolated
1SDC200621F001
Key
ABB Catalogue | 1SDC200023D0201 | 7/33
Emax2_cap07.indd 33
15/04/2013 17:56:16
Emax2_cap07.indd 34
15/04/2013 17:56:17
Electrical diagrams
Reading information
Circuit-breakers
8/2
ATS021 and ATS022
8/7
Power controller
8/8
Circuit-breakers
8/9
Terminal box E1.2
8/10
Terminal box E2.2 - E4.2 - E6.2
8/11
Electrical accessories
8/12
ATS021 and ATS022
8/38
8
ABB Catalogue | 1SDC200023D0201 | 8/1
Emax2_cap08.indd 1
12/04/2013 14:05:50
Electrical diagrams
Reading information – Circuit-breakers
Operating state shown
The diagram is shown in the following conditions:
- withdrawable version circuit-breaker, open and racked-in
- with de-energized circuits
- trip units not tripped
- motor operator with unloaded springs.
Versions
The diagram shows a withdrawable version circuit-breaker, but it is also valid for fixed version circuit-breakers.
Fixed version
The control circuits are included between the XV terminals (the X connector is not supplied).
Withdrawable version
The control circuits are included between the poles of the X connector (the XV terminal box is not supplied).
8
Description of figures
1) Supplementary open/closed auxiliary contacts of the circuit-breaker (second set)
2) Ekip Signalling 4K
11) Trip signalling contact
12) Contact for signalling position of loaded springs
13) Motor for loading closing springs- M
14) Trip reset coil - YR
20) Ekip Measuring/Measuring Pro with voltage socket inside the four pole circuit-breaker
21) Ekip Measuring/Measuring Pro with voltage sockets inside the three-pole circuit-breaker and connection for external
neutral
22) Ekip Measuring Pro for residual voltage protection (for Ekip G only)
23) Ekip Measuring/Measuring Pro with external voltage socket
24) Rc residual current protection sensor input
25) Transformer star centre sensor input
26) Zone selectivity
27) Current sensor input on external neutral (only for 3-pole circuit-breakers)
31) Direct auxiliary supply 24V DC and local bus
32) Auxiliary supply through module 110-240V AC/DC or 24-48V DC and local bus
33) Ekip Fan 24V DC
41) Ekip signalling 2K-1
42) Ekip signalling 2K-2
43) Ekip signalling 2K-3
48) Ekip sinchrocheck
51) Ekip COM Modbus RS-485
52) Ekip COM Modbus TCP
53) Ekip COM Profibus
54) Ekip COM Profinet
55) Ekip COM DeviceNet
56) Ekip COM EtherNet IP
57) Ekip COM IEC61850
58) Ekip LINK
61) Ekip COM R Modbus RS-485 Redundant
62) Ekip COM R Modbus TCP Redundant
63) Ekip COM R Profibus Redundant
8/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 2
12/04/2013 14:05:50
64) Ekip COM R Profinet Redundant
65) Ekip COM R DeviceNet Redundant
66) Ekip COM R EtherNet IP Redundant
71) Contact ready to close - RTC
72) Second opening coil - YO2
73) Undervoltage coil - YU
74) Undervoltage coil with external time-lag device - YU, D
75) First opening coil - YO
76) First opening coil with control from protection trip unit - YO, Ekip Com Actuator
77) First closing coil - YC
78) First closing coil with control from protection trip unit - YC, Ekip Com Actuator
79) Second closing coil - YC2
81) Open/closed auxiliary contacts of circuit-breaker (first set)
91) External supplementary open/closed auxiliary contacts of circuit-breaker
95) Contacts for signalling circuit-breakers in racked-in, test, racked-out position
96) Contacts for signalling circuit-breakers in racked-in, test, racked-out position (first set)
97) Supplementary contacts for signalling circuit-breakers in racked-in, test, racked-out position (second set)
98) Circuit-breakers without auxiliary safety voltage
99) Circuit-breakers with auxiliary safety voltage in direct and alternating current
100) ATS021
101) ATS022
102) Third circuit-breaker controlling with ATS022
103) Ekip Signalling 10K
104) Ekip Multimeter
105) Application diagram for Ekip Touch, Hi-Touch, G Touch, G Hi-Touch with Power Controller function.
8
ABB Catalogue | 1SDC200023D0201 | 8/3
Emax2_cap08.indd 3
12/04/2013 14:05:50
Electrical diagrams
Reading information – Circuit-breakers
8
Key
*
A1
A3
A4
BUS1
D
F1
GZi(DBi)
GZo(DBo)
I O1…32
K51
=
=
=
=
=
=
=
=
=
=
=
K51/COM
K51/FAN
K51/MEAS
K51/SIGN
K51/SUPPLY
K51/SYNC
K51/YC
K51/YO
M
M2
O 01...32
O SC
Q
Q/1...Q/25
Q/26...Q/27
RC
RT1…RT3
RTC EKIP
RTC
S33M/1…2
S43
S51
S75E/1…4
S75I/1…5
S75T/1…2
SC
SO
SO1
SR
SZi(DFi)
SZo(DFo)
TI/L1
TI/L2
TI/L3
TI/N
TU1…TU2
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
See the note indicated by the letter
Applications located on the mobile part of the circuit-breaker
Applications located on the fixed part of the circuit-breaker
Indicative devices and connections for control and signalling, outside the circuit-breaker
Serial interface with external bus
Electronic time-lag device of YU undervoltage coil, outside the circuit-breaker
Time-delayed trip fuse
Zone selectivity input for G protection or input in “reverse” direction for D protection
Zone selectivity output for G protection or output in “reverse” direction for D protection
Programmable digital inputs of the EKIP protection trip unit
Electronic overcurrent protection trip unit of the types: EKIP DIP, EKIP TOUCH, EKIP LCD,
EKIP HI-TOUCH , EKIP HI-LCD, EKIP G TOUCH, EKIP G LCD, EKIP G HI-TOUCH , EKIP G HI-LCD
Communication module
Ventilation supply module
Measurement module
Signalling module
Optional auxiliary supply module (110-220VAC/DC and 24-48VDC)
Synchronization module
Closing control from the EKIP protection trip unit
Opening control from the EKIP protection trip unit
Motor for loading closing springs
Motor for fans
Programmable signalling contacts of the EKIP protection trip unit
EKIP protection trip unit contact for synchronism control
Circuit-breaker
Auxiliary contacts of circuit-breaker
Auxiliary open/close contacts used internally by the trip unit
RC (residual current) protection sensor
Temperature sensors
Auxiliary ready to close contact of circuit-breaker, used internally by the trip unit
Contact for signalling circuit-breaker is ready to close
Limit contacts of spring loading motor
Switch for presetting remote/local control
Trip signalling contact
Contacts for signalling circuit-breaker in racked-out position (provided only with withdrawable version)
Contacts for signalling circuit-breaker in racked-in position (provided only with withdrawable version)
Contact for signalling circuit-breaker in test position (provided only with withdrawable version)
Pushbutton or contact for closing the circuit-breaker
Pushbutton or contact for immediate opening of the circuit-breaker
Pushbutton or contact for opening the circuit-breaker with time-delayed trip
Pushbutton or contact for electrical resetting of S51trip contact
Input for zone selectivity for S protection or input in “direct” direction for S protection
Output for zone selectivity for S protection or output in “direct” direction for D protection
Current transformer phase L1
Current transformer phase L2
Current transformer phase L3
Current transformer on neutral
Insulation voltage transformer (outside circuit-breaker)
8/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 4
12/04/2013 14:05:50
Uaux
UI/L1
UI/L2
UI/L3
UI/N
UI/O
W2
W9…W13
W9R.W11R
X
XB1...XB7
XF
XF1…XF2
XK1…XK3
XK7
XV
YC
YC2
YO
YO1
YO2
YR
YU
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Auxiliary supply voltage
Current sensor phase L1
Current sensor phase L2
Current sensor on phase L3
Current sensor on neutral
Single-pole current sensor
Serial interface with internal bus (local bus)
RJ45 connector for communication modules
RJ45 connector for redundant communication modules
Delivery connector for auxiliary circuits for withdrawable version of circuit-breaker
Connectors for circuit-breaker applications
Delivery terminal board for position contacts of withdrawable version of circuit-breaker
Contact of the EKIP protection trip unit for activating fans
Connectors for auxiliary circuits of the EKIP protection trip unit
Connector for auxiliary circuits of communication module
Delivery terminal box for auxiliary circuits of fixed version circuit-breaker
Closing coil
Second closing coil
Opening coil
Opening coil for overcurrent
Second opening coil
Coil for electrical resetting of trip contact S51
Undervoltage coil
8
ABB Catalogue | 1SDC200023D0201 | 8/5
Emax2_cap08.indd 5
12/04/2013 14:05:50
Electrical diagrams
Reading information – Circuit-breakers
8
Notes
A) Auxiliary supply for Ekip trip unit is mandatory ( refer to diagram 1SDM00009R0001 figures 31 - 32- 33 - 34).
C) Always supplied with Ekip Com module.
D) Always supplied with motor for loading closing springs in Fig. 13.
E) Obligatory voltage transformer in the case of external sockets. Obligatory external sockets for systems with rated voltage
greater than 690V.
F) The connections between the RC residual current protection sensor and the poles of the X connector (or XV) of the circuitbreaker must be made with 4-pole shielded cable with conductors interwoven in pairs (type BELDEN 9696 paired or
equivalent), of a length no greater than 10 m. The shield should be earthed on circuit-breaker side.
G) With all electronic protection trip units equipped with display interface with LSIG protections, protection against an earth
fault is available (Gext) by means of current sensor positioned on the star centre of the MV/LV transformer.
The connection between terminals 1 and 2 of the UI/O current transformer and Ge+ and Ge- poles of the X connector (or
XV) must be made with shielded and stranded 2-pole cable (type BELDEN 8762/8772 or equivalent) of length no greater
than a 15 m. The shield should be earthed on the circuit-breaker side and current sensor side.
H) The connection between the terminal box and external neutral sensor must be made with the 2m cable provided. The Ne+
and Ne- poles of the X connector (or XV) must be short-circuited if no sensor is present on the external neutral conductor.
I) Obligatory in the case of the presence of any Ekip module.
J) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-34.
N.B.: Ekip Fan 24VDC occupies in the terminal box the space of the Ekip Supply and one slot Module.
K) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-33.
K) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-33.
N.B.: Ekip Fan 220VAC occupies in the terminal box the space of the Ekip Supply and two slot Modules.
L) In the presence of Fig. 32, for E2.2, E4.2 and E6.2 circuit-breakers up to three applications between Fig. 41…58 taken only
once can be supplied, instead for E1.2 circuit-breakers, up to two applications between Fig. 41…58 taken only once can be
supplied. The Ekip Com module selected can be duplicated if required, by choosing between Fig. 61…66.
M) In the presence of Fig. 33, for E2.2, E4.2 and E6.2 circuit-breakers, up to two applications between Fig. 41…58 taken only
once can be supplied. The Ekip Com module selected can be duplicated if required, by choosing between Fig. 61…66.
N) In the presence of Fig. 34, for E2.2, E4.2 and E6.2 circuit-breakers, a single application between Fig. 41…58 can be
supplied.
O) In the presence of several Ekip Com modules with withdrawable version circuit-breakers, the contact S75I/5 should be
connected only once to a single module.
P) The auxiliary voltage Uaux. enables activation of all the functions of the EKIP electronic protection trip units. Since an earth
insulated Uaux was requested, it is necessary to use “galvanically separated convertors” which comply with the standards
IEC 60950 (UL 1950) or equivalent, which guarantee a common mode current or leakage current (refer to IEC 478/1, CEI
22/3) no greater than 3.5mA, IEC 60364-41 and CEI 64-8.
Q) Regarding local bus the maximum cable lenght is 15m.
8/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 6
12/04/2013 14:05:50
Electrical diagrams
Reading information – ATS021 and ATS022
Operating state shown
The diagram is shown in the following conditions:
- circuit-breakers open and racked-in #
- with de-energized circuits
- trip units not tripped *
- unloaded closing springs.
Key
A
CB1-N
CB2-E
K1
K2
KC1-KC2
KO1-KO2
M
Q/1
Q60
Q61/1-2
S11
S11...S15
S1-S2
S3
S33M/1
S51
S75I/1
BUS 1
X
XF
XV
YC
YO
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
ATS021 and ATS022 devices for automatic switching of two circuit-breakers
Normal supply line circuit-breaker
Emergency supply line circuit-breaker
Auxiliary contactor type NF22E for voltage presence of normal power supply
Auxiliary contactor type NF22E for voltage presence of emergency power supply
Auxiliary contactors type AL__-30 for the closing of the circuit-breakers
Auxiliary contactors type AL__-30 for the opening of the circuit-breakers
Motor for loading the closing springs
Auxiliary contact of the circuit-breaker
Thermal relay for isolating and protecting the auxiliary circuits of safety auxiliary voltage
Thermal relays for isolating and protecting the auxiliary circuits of the lines
Contact for enabling automatic switching of the ATS021 device
Signalling contacts for the inputs of the ATS022 device
Contacts controlled by the cam of the motor operator
Changeover contact for electrical signalling of local/remote selector state
Limit contacts of spring loading motor
Contact for electrical signalling of circuit-breaker open due to tripping of overcurrent trip unit
Contact for signalling circuit-breaker racked-in #
Serial interface with control system (MODBUS EIA RS485 interface) available with the device ATS022
Connector for auxiliary circuits of withdrawable version circuit-breakers
Delivery terminal box for the position contacts of the circuit-breaker
Delivery terminal box for the auxiliary circuits of the fixed version circuit-breakers
Shunt closing release
Shunt opening release
8
#
This diagram shows the withdrawable version circuit-breakers, but it is also valid for the fixed version circuit-breakers.
In this case, it is not necessary to connect the S75I/1 contacts on the X31:1 input of the ATS021 device otherwise it is
necessary to connect the X32:5 and X32:6 terminals with the terminal X32:9 of the ATS022 device.
*
This diagram shows circuit-breakers with overcurrent release but it is also valid for circuit-breakers without release (switchdisconnectors). If the S51 contact is not present, the S51contacts on the X31:1 input of the ATS021 device should not be
considered, while it is necessary to connect the X32:7 and X32:8 terminals with the X32:9 terminal of the ATS022 device.
ABB Catalogue | 1SDC200023D0201 | 8/7
Emax2_cap08.indd 7
12/04/2013 14:05:50
Electrical diagrams
Reading information – Power Controller
Operating state shown
The diagram is shown in the following conditions:
- circuit-breaker, open and racked-in #
- with de-energized circuits
- trip units not tripped *
- motor operator with unloaded springs.
8
Key
A13
A17
A21
Fl
I 01 ... 12
J ..
K51
K51/COM
K51/SIGN
K51/SUPPLY
K51/YC
K51/YO
M
M
O 01 ... 12
Q/1
Q1
Q2
Q3
Q4
R1
S33M/1
S51
S75I/5
W13
X
XV
YC
YO
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
EKIP SIGNALLING 10K unit
MOE actuator unit for stored energy operating mechanism for the Tmax XT circuit-breaker
EtherNet Switch device
Time-delayed trip fuse
Programmable digital inputs of the EKIP protection trip unit
Connectors for auxiliary circuits of the Tmax XT circuit-breaker in the withdrawable version
Electronic overcurrent protection trip unit type EKIP for EMAX 2 circuit-breaker type
Communication module for the EKIP trip unit
Signalling module for EKIP trip unit
Optional auxiliary supply module for the EKIP trip unit
Closing control from the EKIP protection trip unit
Opening control from the EKIP protection trip unit
Motor for loading closing springs for EMAX 2 circuit-breaker type
Motor for opening the circuit-breaker and for loading closing springs for TMAX XT circuit-breaker type
Programmable signalling contacts of the EKIP protection trip unit
Auxiliary contacts of circuit-breaker
Emax 2 circuit-breaker equipped with EKIP POWER CONTROLLER
Emax 2 circuit-breaker
Tmax XT circuit-breaker equipped with MOE actuator unit
Emax 2 MS switch-disconnector
Resistor
Limit contacts of spring loading motor
Trip signalling contact
Contacts for signalling Emax 2 circuit-breaker in racked-in position (provided only for withdrawable version)
RJ45 connector for communication modules
Delivery connector for auxiliary circuits for withdrawable version of Emax 2 circuit-breaker
Delivery terminal box for auxiliary circuits of fixed version circuit-breaker
Closing coil
Opening coil
8/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 8
12/04/2013 14:05:50
Electrical diagrams
Circuit-breakers
3-pole or 4-pole circuit-breaker
A
UPPER
N
L1
L2
L3
K51
XK1
1
Q
T11
A1
XK1
13
TI/L1
T12
T21
11
TI/L2
T22
12
T31
9
TI/L3
T32
10
T41
7
TI/N
T42
8
XK1
21
T13
UI/L1
UI/L2
UI/L3
UI/N
>
YO1
14
T14
22
T23
19
T24
20
T33
17
T34
18
T43
15
T44
16
>>
2
XK3
>>
7
Q/26
>>
>
>>
8
XK3
9
Q/27
EKIP DIP
EKIP TOUCH
EKIP HI-TOUCH
EKIP LCD
EKIP HI-LCD
EKIP G TOUCH
EKIP G HI-TOUCH
EKIP G LCD
EKIP G HI-LCD
10
XK3
5
RTC EKIP
6
* C)
8
LOWER
3-pole or 4-pole switch-disconnector
B
N
L1
L2
L3
A1
1SDC200622F001
Q
ABB Catalogue | 1SDC200023D0201 | 8/9
Emax2_cap08.indd 9
12/04/2013 14:05:50
Electrical diagrams
Terminal box E1.2
LOCAL BUS
K51/MEAS
VN
23
L1 L2 L3
14
M
13
44
Q4
Q1
34
24
Q2
C2 C12 14
Q3
YO
RTC YU YC
YO2
42
32
31
D2
Module
Module
and/or communication modules
51 ..
.. 58
and/or redundant communication modules
61 ..
.. 66
R2
S33M/1
S33M/2
11
S51
Trip Unit I/O
Transformer star centre sensor input
26
RC residual current protection sensor input
25
Ekip Measuring voltage sockets
24
20 21 22 23
U1
U2
12
27
VN
V1
V2
V3
R1
F1
Zone selectivity
36
38
35
96
98
95
14
13
12
Trip signalling contact
11
YR reset trip coil
Closing springs loading motor
Contact for signalling position of loaded springs
1SDC200623F001
K51/MEAS
21
22
Szi
Szo
Gzi
Gzo
Szc
V1 Gzo Szc Gzi
K51/MEAS
48
YR
24
and/or Ekip synchro check
..
66
26
Rct
Rca
Ge+
Ge-
41 42 43
M
K31
K51
N L1 L2 L3
31 32
Signalling modules
U2
K33
W..R
YR
K51
20
Auxiliary supply and local bus
38
I 31
61
..
K51/COM
K32
K51/SIGN
..
K51
25
71
58
98
K34
K51/SIGN
HC3
Ge +
Ge –
Current sensor input on external neutral
S51 S33
I 32
K21
Szi
K23
Szo
I 21
W..
Vn Ge
K24
Rct Ge
I 22
K51/SIGN
51
..
K51/COM
K22
V3
K51/SIGN
V2
H31
73 74
VS1
VS2
R1
O 32
H32
Vs
K11
R2
K51/SIGN
O 31
K51/SIGN
72
Ready to close contact
K51/SYNC
HC2
43
75 76
Second opening coil or undervoltage coil
48
U1
H21
K13
First closing coil
KS2
36
H22
I 11
KS1
O SC
35
O 22
K51/SIGN
O 21
K51/SIGN
K14
K51/SIGN
HC1
42
K51/SYNC
K12
I 12
K1
K2
96
H11
K51/SIGN
PORTA COMUNIC.
COMMUN. PORT
K51/SIGN
H12
W3
W4
ALIM. AUS. +/L
AUX. SUPPLY -/N
PORTA COMUNIC.
COMMUN. PORT
RIDONDANTE
REDUNDANT
K51/SIGN
O 11
8
41
O 12
31
32
48
K51/..
Rca
27
K2
Ne+
Ne-
W4
K51
45
46
48
45
RTC
71
46
in alternative
Ne
D1
D1
C2
D2
77 78
TU
I/O
C3
YC
Ne
K51
First opening coil
EKIP Supply
C1
K1
73
74
D1
D2
C12
W3
YO
76
C13
YO
95
72
C11
K51
YC
C1
C2
YO2
75
78
YU
YO
C11
C12
YC
77
81
22
Q/1
n
Open/closed auxiliary contacts
of circuit-breaker (first set)
21
Q/2
C3 C13 12
Q/3
81
C1 C11 11
42
44
41
32
34
31
22
24
21
12
14
11
Q/4
41
Diagram figure number
8/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 10
12/04/2013 14:05:51
Electrical diagrams
Terminal box E2.2 - E4.2 - E6.2
K32
K51/COM
I 32
K34
I 31
K33
44
Q4
34
24
Q2
C2 C12 C22 14
YO YC2 Q1
Q3
32
22
D2
48
YU YC
RTC YO2
31
21
D1
45
12
TU
I/O
EKIP Supply
Rca
K2
Current sensor input on external neutral
71
Auxiliary supply and local bus
31 32
Ventilation control
33
Module
Signalling modules
41 42 43
and/or Ekip synchro check
48
and/or communication modules
51 ..
.. 58
and/or redundant communication modules
61 ..
.. 66
Module
Trip Unit I/O
V1 Gzo Szc Gzi
Szi
Vn Ge
Zone selectivity
27
Transformer star centre sensor input
26
RC residual current protection sensor input
20 21 22 23
14
13
12
Trip signalling contact
11
Ekip signalling 4K
2
Supplementary auxiliary contacts
of circuit-breaker (second set)
1
YR
M
S51 S33
K5
K8
94
K4
K7
84
EKIP Signalling 4K
U2
K6
04
K9 K10
98
38
U1
36
35
96
95
H4
02
01
1
1SDC200624F001
Q/5
in alternative
HC
Q/6
Q5..Q10
Q/7
K3
Q/8
H3
Q/9
02
04
01
92
94
91
82
84
81
72
74
71
62
64
61
52
54
51
Contact for signalling position of loaded springs
74
K7
Q/10
HC
K8
K3
O 01
11
S51
Motor for loading closing springs
64
O 02
K51/SIGN
12
36
38
35
96
98
95
25
24
Ekip Measuring voltage sockets
YR reset trip coil
54
K9
K4
U2
S33M/2
92
K5
O 03
K51/SIGN
U1
91
K51/SIGN
K10
R2
S33M/1
H2
K6
O 04
F1
82
13
M
R1
81
K51/SIGN
14
HC
2
75 76
72
Ready to close contact
L1 L2 L3
H1
H1
23
VN
V1
V2
V3
72
H2
VN
71
H3
K51/MEAS
HC
H4
Szi
Szo
Gzi
Gzo
Szc
62
I 01
I 02
I 03
I 04
N L1 L2 L3
66
26
YR
20
21
22
..
K51
Rct
Rca
Ge+
Ge-
K51/MEAS
61
..
W..R
Rct Ge- Szo
Ne+
Ne-
58
V2
K31
Module
K23
24
K51/MEAS
K51/SIGN
Second opening coil or undervoltage coil
..
I 21
K51
Ge+
Ge-
W..
V3
K21
K51/SIGN
51
..
K51/COM
K22
61
H31
K51
K51/SIGN
77 78
First closing coil
8
R2
K24
27
K51/SIGN
79
First opening coil
VS1
VS2
K51
K51/SIGN
Second closing coil
48
52
O 32
I 22
K51/SIGN
HC3
25
K2
51
K51/SIGN
K13
K51/SIGN
H32
O 31
K51/SIGN
Vs
K11
I 11
K51/SIGN
HC2
43
K1
R1
K51/SIGN
PORTA COMUNIC.
COMMUN. PORT
H21
KS1
81
KS2
PORTA COMUNIC.
COMMUN. PORT
RIDONDANTE
REDUNDANT
O 12
O 22
K51/SIGN
H22
O 21
K51/SIGN
W3
ALIM. AUS.
AUX. SUPPLY -/N
Open/closed auxiliary contacts
of the circuit-breaker (first set)
73 74
W4
+/L
n
K51/SYNC
HC1
42
K51/..
XSC
K14
D1
46
48
45
RTC
K51/SYNC
K12
I 12
H11
O 11
K51/SIGN
K51/SIGN
H12
C2
D2
71
31
32
33
34
K51/SIGN
C3
YC
W4
in alternative
41
K51
Ne-
D2
C1
Ne
73
74
D1
C12
K1
76
C2
YO
W3
C1
C13
LOCAL BUS
YC
72
78
C12
K51
YC
75
YO2
77
C11
YU
YO
C11
C21
C22
YO
79
C3 C13
YC2
Q/1
C1 C11 C21 11
Q/2
46
Q/3
81
41
42
44
41
32
34
31
22
24
21
12
14
11
Q/4
42
Diagram figure number
ABB Catalogue | 1SDC200023D0201 | 8/11
Emax2_cap08.indd 11
12/04/2013 14:05:51
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
11
21
31
41
12
22
32
42
14
24
34
44
Q1
Q2
Q3
Q4
81) Open/closed auxiliary contacts of circuit-breaker (first set)
81
A4
8
32
34
42
44
32
34
42
44
XV
11
21
31
41
X
11
21
31
41
A4
1SDC200626F001
41
Q/4
31
Q/3
21
Q/2
34
24
22
Q/1
11
A1
44
24
24
42
22
22
32
14
14
14
12
12
12
X
XV
8/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 12
12/04/2013 14:05:51
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
45
D1
C1 C11 C21
C3 C13
46
48
YO YC2 Q1
D2
C2 C12 C22
YU YC
RTC YO2
YO YC2
77) First closing coil - YC
78) First closing coil with control from protection trip unit - YC, Ekip Com Actuator
79) Second closing coil - YC2
77
78
+
~
+
~
SC
SC
79
+
~
A4
SC
S43
8
C3
C21
C3
C21
C3
C21
C1
C1
C1
C1
C1
XK7
9
K51
YC
A1
XK7
1
XB3
YC
XB3
3
YC2
2
XB3
C2
2
C2
XB3
1
XB3
YC
10
4
C22
XB3
K51
Ekip Com Actuator
C1
X
XV
C2
C2
C22
X
C2
C2
C22
A4
~
~
~
1SDC200627F001
XV
77- 78 as an alternative to each other
79 valid only for E2.2 - E4.2 - E6.2
ABB Catalogue | 1SDC200023D0201 | 8/13
Emax2_cap08.indd 13
12/04/2013 14:05:52
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
45
D1
C1 C11 C21
C3 C13
46
48
YO YC2 Q1
D2
C2 C12 C22
YU YC
RTC YO2
YO YC2
75) First opening coil - YO
76) First opening coil with control from protection trip unit - YO, Ekip Com Actuator
75
76
+
~
+
~
SO
SO
A4
S43
C11
C13
C11
C13
C13
C11
C11
C11
XK7
7
K51
YO
A1
XK7
XB4
1
XB4
YO
1
XB4
2
C12
2
XV
C12
C12
X
C12
C12
A4
~
8
YO
C12
XB4
K51
Ekip Com Actuator
C11
X
XV
~
1SDC200628F001
8
75-76 as an alternative to each other
8/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 14
12/04/2013 14:05:52
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
45
D1
C1 C11 C21
C3 C13
46
48
YO YC2 Q1
D2
C2 C12 C22
YU YC
RTC YO2
71)
72)
73)
74)
YO YC2
Contact ready to close - RTC
Second opening coil - YO2
Undervoltage coil - YU
Undervoltage coil with external time-lag device - YU, D
71
72
73
+
~
+
~
74
+
~
A4
SO
SO1
SO
SO
8
D1
D1
D1
D1
XB6
48
2
D1
D1
D1
D1
48
48
D1
46
46
46
X
XV
3
A1
RTC
XB5
1
XB5
YO2
XB5
YU
1
YU
1
45
2
XB5
XV
45
D2
D2
X
45
D2
D2
D2
D2
~
~
A4
~
~
2
~
D
+
1SDC200629F001
XB5
D2
2
D2
XB5
D2
XB6
1
72-73 or 74 as an alternative to each other
ABB Catalogue | 1SDC200023D0201 | 8/15
Emax2_cap08.indd 15
12/04/2013 14:05:52
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
TU
I/O
EKIP Supply
W3
K1
W4
K2
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
EKIP Supply
32) Auxiliary supply through module 110-240V AC/DC or 24-48V DC and local bus
32
+/L
-/N
Uaux.
A4
X
K1
K2
XV
K1
K2
Ekip Supply 110-240VAC/DC
Ekip Supply 24-48VDC
K51
SUPPLY
XV
W3
W4
X
W3
W4
A4
(H) (L)
* Q)
W2 (LOCAL BUS)
1SDC200630F001
W4
W3
A3
K2
K1
8
110-240VAC/DC
24-48VDC
* I)
As an alternative to figures 31-33
8/16 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 16
12/04/2013 14:05:52
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
TU
I/O
EKIP Supply
W3
K1
W4
K2
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
EKIP Supply
31) Direct auxiliary supply 24V DC and local bus
* P)
A4
31
+
Uaux.
8
24VDC
K1
K2
K1
K2
A3
K2
K1
X
XV
K51
XV
W3
W4
X
W3
W4
A4
(H) (L)
* Q)
W2 (LOCAL BUS)
1SDC200631F001
W4
W3
EKIP
As an alternative to figures 32-33
ABB Catalogue | 1SDC200023D0201 | 8/17
Emax2_cap08.indd 17
12/04/2013 14:05:52
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
W3
K1
W4
K2
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
EKIP Supply
33) Ekip Fan 24V DC
33
* P)
+
A4
Uaux.
8
24VDC
XF1
XF2
XF3
XF4
XF1
XF2
XF3
XF4
XF4
XF2
K2
4
OF AL
Ekip Fan 24VDC
OF ON
3
KM2
2
9
1
10
XF3
K2
K2
XF1
K1
K1
K1
X
XV
K51
FAN
A3
KM2
KM1
6
1
W4
W3
M2
XV
W3
W4
X
W3
W4
A4
(H) (L)
* Q)
(LOCAL BUS)
2
6
M
7
3
RT1
8
t
RT2
4
9
t
RT3
5
10
t
FAN
1SDC200632F001
5
As an alternative to figures 31-32
8/18 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 18
12/04/2013 14:05:53
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
EKIP Supply
TU
I/O
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
Module
41) Ekip signalling 2K-1
42) Ekip signalling 2K-2
41
42
A4
8
K23
H21
H22
HC2
K23
H21
H22
HC2
K51 O 21
SIGN
K23
O 22
I 22
K24
I 21
Ekip Signalling 2K-2
I 12
K22
K14
I 11
K21
K13
O 12
Ekip Signalling 2K-1
K51 O 11
SIGN
K12
A3
HC2
K21
K21
H22
HC1
HC1
H21
H12
H12
HC1
H11
H11
H12
K13
K13
H11
K11
K11
K11
X
XV
XV
K12
K14
K22
K24
X
K12
K14
K22
K24
1SDC200633F001
A4
* L), * M), * N)
* L), * M), * N)
ABB Catalogue | 1SDC200023D0201 | 8/19
Emax2_cap08.indd 19
12/04/2013 14:05:53
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
YO YC2 Q1
Module
43) Ekip signalling 2K-3
48) Ekip sinchrocheck
43
L1
48
TU2
L2
A
a
B
b
A4
8
HC3
KS1
VS2
VS1
HC3
KS1
VS2
VS1
VS2
Ekip Synchrocheck
I 32
K51 O SC
SYNC
K34
KS2
I 31
HC3
K33
O 32
Ekip Signalling 2K-3
K51 O 31
SIGN
K32
A3
VS1
H32
H32
KS1
H31
H31
H32
K33
K33
H31
K31
K31
K31
X
XV
XV
K32
K34
KS2
X
K32
K34
KS2
1SDC200634F001
A4
* L), * M), * N)
* L), * M), * N)
8/20 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 20
12/04/2013 14:05:53
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Module
51) Ekip COM Modbus RS-485
52) Ekip COM Modbus TCP
53) Ekip COM Profibus
51
52
53
A4
X
8
XV
* O)
XK7
n
1
XK7
K51
COM
W5
W9
XK7
194
193
2
K51
COM
W2
W1
K51
COM
1
2
Ekip Com Profibus
XK7
Ekip Com Modbus RS-485
A3
2
Ekip Com Modbus TCP
XK7
194
194
1
RJ45
XK7
S75I/5
193
S75I/5
193
S75I/5
* O)
W6
* O)
XV
W1
W2
W5
W6
X
W1
W2
W5
W6
(A) (B)
BUS 1
* L), * M), * N)
1SDC200635F001
A4
(A) (B)
BUS 1
* L), * M), * N)
BUS 1
* L), * M), * N)
ABB Catalogue | 1SDC200023D0201 | 8/21
Emax2_cap08.indd 21
12/04/2013 14:05:53
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Module
54) Ekip COM Profinet
55) Ekip COM DeviceNet
56) Ekip COM EtherNet IP
54
55
56
A4
X
8
XV
* O)
XK7
XK7
2
XK7
193
194
194
1
S75I/5
193
S75I/5
193
S75I/5
* O)
1
XK7
2
XK7
194
* O)
1
XK7
2
K51
COM
W8
n
W7
RJ45
W10
Ekip Com EtherNet IP
K51
COM
W11
RJ45
K51
COM
Ekip Com DeviceNet
Ekip Com Profinet
A3
n
XV
W7
W8
X
W7
W8
(H) (L)
BUS 1
* L), * M), * N)
BUS 1
* L), * M), * N)
BUS 1
1SDC200636F001
A4
* L), * M), * N)
8/22 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 22
12/04/2013 14:05:54
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Module
57) Ekip COM IEC61850
58) Ekip LINK
57
58
A4
X
8
XV
* O)
* O)
XK7
1
XK7
2
XK7
194
194
193
S75I/5
193
S75I/5
1
XK7
2
RJ45
W12
K51
COM
Ekip Link
K51
COM
W13
RJ45
Ekip Com IEC61850
A3
n
n
XV
X
BUS 1
* L), * M), * N)
BUS 1
1SDC200637F001
A4
* L), * M), * N)
ABB Catalogue | 1SDC200023D0201 | 8/23
Emax2_cap08.indd 23
12/04/2013 14:05:54
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Module
61) Ekip COM R Modbus RS-485 Redundant
62) Ekip COM R Modbus TCP Redundant
63) Ekip COM R Profibus Redundant
61
62
63
A4
X
8
Ekip Com R Profibus
K51
COM
K51
COM
n
W6R
W9R
W5R
W2R
W1R
K51
COM
RJ45
Ekip Com R Modbus RS-485
A3
Ekip Com R Modbus TCP
XV
XV
W1R
W2R
W5R
W6R
X
W1R
W2R
W5R
W6R
(A) (B)
BUS 2
* L), * M), * N)
(A) (B)
BUS 2
* L), * M), * N)
BUS 2
1SDC200638F001
A4
* L), * M), * N)
8/24 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 24
12/04/2013 14:05:54
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Module
64) Ekip COM R Profinet Redundant
65) Ekip COM R DeviceNet Redundant
66) Ekip COM R EtherNet IP Redundant
64
65
66
A4
X
8
XV
K51
COM
W8R
n
W7R
RJ45
W10R
Ekip Com R EtherNet IP
K51
COM
W11R
RJ45
K51
COM
Ekip Com R DeviceNet
Ekip Com R Profinet
A3
n
XV
W7R
W8R
X
W7R
W8R
1SDC200639F001
A4
(H) (L)
BUS 2
* L), * M), * N)
BUS 2
* L), * M), * N)
BUS 2
* L), * M), * N)
ABB Catalogue | 1SDC200023D0201 | 8/25
Emax2_cap08.indd 25
12/04/2013 14:05:54
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
V3
Vn Ge
V2
Rct Ge- Szo
Module
Module
TU
I/O
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
Ne-
Szi
Ne
V1 Gzo Szc Gzi
Rca
Trip Unit I/O
TU
I/O
25) Transformer star centre sensor input
27) Current sensor input on external neutral (only for 3-pole circuit-breakers)
PE
L1
L2
L3
25
N
27
N
8
UI/O
A4
UI/N
4
1
* H)
* G)
Ne-
Ne+
Ne-
Ne+
Ne-
Ne+
Ge+
Ge+
Ge+
GeGeGe-
X
XV
A1
K51
K51
EKIP
EKIP
XV
A4
1SDC200640F001
X
As an alternative to figure 24
8/26 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 26
12/04/2013 14:05:55
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
V3
Vn Ge
V2
Rct Ge- Szo
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Szi
V1 Gzo Szc Gzi
Trip Unit I/O
24) Rc residual current protection sensor input (ANSI 64 & 50NTD)
24a) Rc differential ground fault protection (ANSI 87N)
24
24a
L1
4
Idn : 3A ... 30A
Idn : 3A ... 30A
3
A4
L2
L3
4
8
3
2
2
1
1
RC
RC
N
L1
L2
L3
PE
* F)
Ge-
Ge+
Ge-
Ge+
Rca
Ge+
Rct
Rct
Ge-
Rca
Rca
Rct
Ge+
Ge+
Ge+
GeGe-
Ge-
Rct
Rct
Rct
Rca
Rca
Rca
X
XV
A1
K51
K51
EKIP
EKIP
XV
1SDC200641F001
X
A4
As an alternative to figure 25
ABB Catalogue | 1SDC200023D0201 | 8/27
Emax2_cap08.indd 27
12/04/2013 14:05:55
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
V3
Vn Ge
V2
Rct Ge- Szo
Module
Module
TU
I/O
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
Szi
V1 Gzo Szc Gzi
Trip Unit I/O
22) Ekip Measuring Pro for residual voltage protection (for Ekip G only)
23) Ekip Measuring/Measuring Pro with external voltage socket
22
Earthing security
busbar of the
switchgear or earthing
mesh of
the plant
8
L1
L2
23
TU1
N L1 L2 L3
L3
A4
A1
a1
B1
b1
A2
a2
B2
b2
A3
a3
B3
b3
* E)
X
VN
V3
V2
V1
VN
V3
V2
V1
XV
VN
V3
V2
V1
VN
V3
V2
V1
L1 L2 L3
K51
MEAS
Ekip Measuring
Ekip Measuring Pro
K51
MEAS
Ekip Measuring Pro
A1
XV
A4
1SDC200642F001
X
As an alternative to each other or to 20-21 diagram
8/28 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 28
12/04/2013 14:05:55
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
V3
Vn Ge
V2
Rct Ge- Szo
Module
Module
TU
I/O
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
Szi
V1 Gzo Szc Gzi
Trip Unit I/O
20) Ekip Measuring/Measuring Pro with voltage socket inside the four pole circuit-breaker
21) Ekip Measuring/Measuring Pro with voltage sockets inside the three-pole circuit-breaker and connection to
the external neutral
20
21
N
8
A4
X
VN
V3
V2
V1
VN
V3
V2
V1
XV
VN
V3
V2
V1
VN
V3
V2
V1
N
L1 L2 L3
L1 L2 L3
K51
MEAS
Ekip Measuring
Ekip Measuring Pro
K51
MEAS
Ekip Measuring
Ekip Measuring Pro
A1
XV
1SDC200643F001
X
A4
As an alternative to each other or to 22-23 diagram
ABB Catalogue | 1SDC200023D0201 | 8/29
Emax2_cap08.indd 29
12/04/2013 14:05:55
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
95
35
96
36
U1
98
38
U2
S51 S33
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
V3
Vn Ge
V2
Rct Ge- Szo
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
Szi
V1 Gzo Szc Gzi
Trip Unit I/O
26) Zone selectivity
26
A4
Gzi
Gzo
Gzi
Gzo
A1
Gzi
SZo
(DFo)
SZi
(DFi)
K51
Gzo
Szo
Szo
Szo
Szi
Szi
Szi
8
X
XV
GZo
(DBo)
GZi
(DBi)
Szc
EKIP
XV
Szc
X
Szc
A4
Example for application diagram (among 3 circuit-breakers)
K51
Szc
Q1
Szo
Szi
Gzo
Gzi
K51
Szc
Q2
Szo
Szi
Gzo
Gzi
Szc
Q3
Szo
Szi
Gzo
Gzi
1SDC200644F001
K51
8/30 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 30
12/04/2013 14:05:55
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
95
35
96
36
U1
98
38
U2
S51 S33
EKIP Signalling 4K
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
R1
95
35
96
36
U1
98
38
U2
S51 S33
11)
12)
13)
14)
M
R1
M
R2
YR
Trip signalling contact - S51
Contact for signalling position of loaded springs - S33
Motor for loading closing springs - M
Trip contact reset coil – YR
11
12
13
+
~
14
+
~
A4
SR
8
36
38
U1
R1
36
38
U1
R1
U1
38
98
XB1
XB7
2
3
XB2
A1
2
3
4
1
S33M/1
2
F1
S33M/2
S51
R1
98
98
36
96
96
96
X
XV
1
XB2
2
35
U2
XB1
95
YR
M
1
XV
95
35
U2
R2
X
95
35
U2
R2
A4
~
~
1SDC200645F001
1
R2
XB7
* D)
ABB Catalogue | 1SDC200023D0201 | 8/31
Emax2_cap08.indd 31
12/04/2013 14:05:56
Electrical diagrams
Electrical accessories
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
51
61
52
62
54
64
HC
HC
HC
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
71
72
74
Q5..Q10
2)
71
H1
K3
K7
81
82
84
H2
K4
K8
91
92
94
H3
K5
K9
95
35
96
36
U1
98
38
U2
S51 S33
01
02
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
TU
I/O
EKIP Supply
D1
YO YC2 Q1
H4
K6
04
K10
EKIP Signalling 4K
Ekip Signalling 4K
2
A4
8
H1
H2
H3
H4
HC
H1
H2
H3
H4
HC
I 02
H4
I 03
I 04
XV
K7
K8
K9
K10
HC
HC
X
K7
K8
K9
K10
HC
HC
A4
1SDC200646F001
HC
K10
I 01
Ekip Signalling 4K
O 04
K9
O 03
HC
K6
K5
K4
O 02
K8
K51 O 01
SIGN
K7
A1
HC
K6
K6
H3
K5
K5
H2
K4
K4
H1
K3
K3
K3
X
XV
Only for circuit-breakers E2.2, E4.2, E6.2 (as an alternative to figure 1)
8/32 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 32
12/04/2013 14:05:56
51
61
52
62
54
64
HC
C
HC
C
HC
C
Q5..Q10
51
61
52
62
54
64
HC
HC
HC
Q5..Q10
71
72
74
H1
K3
3
K7
7
81
82
84
H2
K4
4
K8
8
91
92
94
H3
3
K5
5
K9
9
01
02
H4
4
K6
6
04
K10
0
EKIP Signalling 4K
71
72
74
H1
K3
K7
81
82
84
H2
K4
K8
91
92
94
H3
K5
K9
95
35
96
36
U1
98
38
U2
S51 S33
01
02
M
R1
V3
Vn Ge
Ne-
45
R2
V2
Rct Ge- Szo
W3
K1
Ne
46
V1 Gzo Szc Gzi
W4
K2
Rca
48
YR
Szi
Trip Unit I/O
Module
Module
Module
TU
I/O
EKIP Supply
D1
C1 C11 C21 11
21
31
41
12
22
32
42
C2 C12 C22 14
24
34
44
Q2
Q3
Q4
C3 C13
D2
YU YC
RTC YO2
YO YC2 Q1
H4
K6
04
K10
EKIP Signalling 4K
1) Supplementary open/closed auxiliary contacts of the circuit-breaker (second set)
1
A4
8
82
84
92
94
02
04
82
84
92
94
02
04
94
84
Q/10
01
Q/9
91
Q/8
81
61
Q/7
71
Q/6
74
64
54
Q/5
51
A1
04
74
74
02
72
72
92
64
64
82
62
62
72
54
54
62
52
52
52
X
XV
XV
51
61
71
81
91
01
X
51
61
71
81
91
01
1SDC200647F001
A4
Only for circuit-breakers E2.2, E4.2, E6.2 (as an alternative to figure 2)
ABB Catalogue | 1SDC200023D0201 | 8/33
Emax2_cap08.indd 33
12/04/2013 14:05:56
Electrical diagrams
Electrical accessories
91) Supplementary open/closed auxiliary contacts outside the circuit-breaker
91
202
204
Q/11
282
214
Q/12
201
A4
8
212
284
Q/19
292
224
Q/13
211
294
Q/20
302
234
Q/14
221
304
Q/21
291
232
312
244
Q/15
231
314
Q/22
301
242
322
254
Q/16
241
324
Q/23
311
252
332
264
Q/17
251
334
Q/24
321
262
274
Q/18
261
342
272
271
344
Q/25
331
341
1SDC200648F001
281
222
8/34 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 34
12/04/2013 14:05:56
95) Contacts for signalling circuit-breakers in racked-in, test, racked-out position
95
A4
2
4
S75E/1
142
154
4
S75E/2
1
1
2
A3
4
S75T/1
2
4
S75T/2
1
1
4
2
S75I/1
4
2
111
121
131
141
151
1SDC200649F001
A4
1
151
141
131
121
111
101
101
8
S75I/2
1
XF
152
152
144
154
134
142
132
144
124
134
114
2
122
132
114
124
112
122
104
104
102
102
112
XF
Only for circuit-breakers E1.2 in withdrawable version
ABB Catalogue | 1SDC200023D0201 | 8/35
Emax2_cap08.indd 35
12/04/2013 14:05:56
Electrical diagrams
Electrical accessories
96) Contacts for signalling circuit-breakers in racked-in, test, racked-out position (first set)
96
A4
2
S75I/1
4
124
134
142
2
S75I/2
1
1
2
4
S75T/1
1
2
4
S75E/1
2
4
S75E/2
111
131
121
111
101
A4
101
121
1
141
1
8
131
141
1SDC200650F001
A3
XF
144
144
132
142
124
134
122
132
114
122
102
4
112
114
104
104
102
112
XF
Only for circuit-breakers E2.2, E4.2, E6.2 in withdrawable version
8/36 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 36
12/04/2013 14:05:57
97) Supplementary contacts for signalling circuit-breakers in racked-in, test, racked-out position (second set)
97
A4
2
S75I/3
4
174
184
192
2
S75I/4
1
1
2
4
S75T/2
A3
1
2
4
S75E/3
2
4
S75E/4
151
171
8
191
181
171
161
1
181
191
1SDC200651F001
A4
161
151
1
XF
194
194
182
192
174
184
172
182
164
172
152
4
162
164
154
154
152
162
XF
Only for circuit-breakers E2.2, E4.2, E6.2 in withdrawable version
ABB Catalogue | 1SDC200023D0201 | 8/37
Emax2_cap08.indd 37
12/04/2013 14:05:57
Electrical diagrams
ATS021 and ATS022
98) Circuit-breakers without auxiliary safety voltage
98
NORMAL SUPPLY
N
Q61/1
L1
L2
EMERGENCY SUPPLY
L3
N
L1
L2
L3
Q61/2
6
5
5
6
4
3
3
4
2
1
1
2
8
7
7
8
CB1-N
CB2-E
M
M
#
#
X61
A
4
3
1
2
2
3
4
1
2
ONLY FOR ATS021
21
K1
22
1
22
2
X21
21
DO1
DO3
3
A1
K1
K2
A2
A2
X
C11
X
C1
X
U1
X
C11
X
C1
X
U1
XV
C11
XV
C1
XV
U1
XV
C11
XV
C1
XV
U1
43
K2
44
44
YO
YC
S33M
1
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
CB2-E
43
CB1-N
S33M
1
K1
DO2
A1
YO
YC
1
2
3
DO4
ATS021 - ATS022
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
1SDC200652ENF001
K2
X22
8
X12
14
K2
14
1
X14
2
X13
K1
13
X11
1
13
8/38 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 38
12/04/2013 14:05:57
99) Circuit-breakers with auxiliary safety voltage in direct current
99
3
2
1
1L1
4
1L1
KO1
1L1
KC1
KO2
1L1
2
3
KC2
2T1
2T1
2T1
2T1
3L2
3L2
3L2
3L2
KO1
KC1
KO2
4T2
4T2
4T2
2
5L3
5L3
5L3
5L3
3
KC1
6T3
KO2
KC2
6T3
6T3
6T3
C11
X
C1
X
U1
X
C11
X
C1
X
U1
XV
C11
XV
C1
XV
U1
XV
C11
XV
C1
XV
U1
YC
DO4
S33M
1
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
CB2-E
CB1-N
YO
DO3
DO2
ATS021 - ATS022
A
X
S33M
1
DO1
1
KC2
4T2
KO1
X21
-
Q60
X22
1
POSIZIONE
CODICE
ACODICE0
ACODICE1
ACODICE2
UBICAZIONE
NOTE1
NOTE2
+
NOTE2
NOTE1
UBICAZIONE
ACODICE2
ACODICE1
ACODICE0
CODICE
POSIZIONE
-+
YO
YC
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
A1
A1
A1
A1
KO1
KC1
KO2
KC2
A2
A2
A2
A2
8
99) Circuit-breakers with auxiliary safety voltage in alternating current
N
3
Q60
2
1
4
2
X21
1
NOTE2
NOTE1
UBICAZIONE
ACODICE2
ACODICE1
ACODICE0
CODICE
POSIZIONE
L
POSIZIONE
CODICE
ACODICE0
ACODICE1
ACODICE2
UBICAZIONE
NOTE1
NOTE2
~
DO1
X22
99
DO3
3
1
2
3
X
C11
X
C1
X
U1
X
C11
X
C1
X
U1
XV
C11
XV
C1
XV
U1
XV
C11
XV
C1
XV
U1
YO
YC
DO4
ATS021 - ATS022
S33M
1
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
CB2-E
CB1-N
S33M
1
A
DO2
YO
YC
M
XV
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
ABB Catalogue | 1SDC200023D0201 | 8/39
Emax2_cap08.indd 39
12/04/2013 14:05:57
Electrical diagrams
ATS021 and ATS022
100) ATS021
100
1
X12
3
3
X22
CB2-E
1
2
3
CB2-E
X XV
CB1-N
XF
S51
95
S75I/1
142
*
XV
X
CB2-E
XF
96 96
#
XF
141
X XV
96
S51
96
*
XV
DO4
DO8
STOP GENERATOR COMMAND
1 ATS021 NORMAL OPERATING SIGNALLING
2
3
DO7
ALIM. L2
X14
X23
1 START GENERATOR COMMAND
2
ATS021 ALARM SIGNALLING
1
2
MANUAL MODE SIGNALLING
3
LOGIC ENABLE/DISABLE SIGNALLING
X
95 95
1
Q/1
XV
Q/1
XV
2
14 14
11 11
X XV
X
X31
X XV
X
3
14 14
11 11
8
DO6
DO3
XF
S11
CB2-E
1
2
3
142
LOGIC ENABLE/DISABLE
CB1-N
DO2
#
S75I/1
141
CB1-N
DO5
DO1
X24
X21
CB1-N
2
X25
1
2
1
95
3
4
X13
ALIM. L1
4
2
MEASURE L2
X61
1
2
X11
MEASURE L1
A
4
ATS021
101) ATS022
101
X12
X21
X22
CB2-E
3
CB2-E
CB1-N
#
*
*
XF
XF
141
142
X XV
XV
95
X XV
95
S51
95
95
96 96
S51
XV
DI9
4
DI8
6
X
X
96 96
DI10
3
5
142
S75I/1
DO10
2
NOT USED
3
NOT USED
4
CIRCUIT-BREAKER ALARM SIGNALLING
5
MANUAL MODE SIGNALLING
6
LOGIC ENABLE/DISABLE SIGNALLING
7
1
2
BUS 1
3
DI7
7
DI5
8
DI4
9
COM
S11
1
DI6
2
X31
CB1-N
XF
1 ATS022 ALARM SIGNALLING
X51
PROGRAMMABLE INPUT
S75I/1
DO7
2
X32
S15
XF
DO4
(SEE FIG. 102)
DO8
2
COMMAND TO FORCE TO TRANSFER
141
DO6
1 CB3 CIRCUIT-BREAKER POSITION
DO12
S13
#
DO3
1
S14
CB2-E
DO11
DO9
S12
START GENERATOR COMMAND
(NA/NC PROGRAMMABLE)
DO2
3
1
CB3 CIRCUIT-BREAKER POSITION
(SEE FIG. 102)
DO1
STOP GENERATOR COMMAND
3
ATS022
4
LOGIC ENABLE/DISABLE
X XV
Q/1
X XV
X
11 11
14 14
14 14
XV
Q/1
XV
11 11
X
CB1-N
CB2-E
1SDC200653ENF001
CB1-N
3
2
1 START GENERATOR COMMAND
2
3
1
2
DO5
X23
1
2
X24
24...110Vdc
-
X29
+
3
4
X41
4
(A) (B)
3
1
2
MEASURE L2
X61
1
2
X11
MEASURE L1
A
8/40 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 40
12/04/2013 14:05:58
102) Third circuit-breaker control with ATS022
102
A
~
CB3 CIRCUIT-BREAKER POSITION
Q/1
CB3
XV
X
1
11 11
DO11
1
X24
X XV
14 14
16
KO3
2
Impulse-OFF
15
3
2
16
3
X
31
X
21
XV
31
XV
21
Q/3
XV
X32
X
XV
34
X
Impulse-OFF
15
CB3
34
18
KC3
Q/2
CB3
4
5
18
X
C11
X
C1
X
U1
XV
C11
XV
C1
XV
U1
22
22
S33M
1
6
7
8
ATS 022
A1 Y1
KO3
KC3
A2
A2
YC
M
C12
XV
C2
XV
U2
X
C12
X
C2
X
U2
~
1SDC200654ENF001
9
A1 Y1
CB3
YO
XV
8
Possible configurations - ATS022 with three circuit-breakers
NORMAL SUPPLY EMERGENCY SUPPLY
CB1-N
CB2-E
M
M
NORMAL SUPPLY
EMERGENCY SUPPLY
CB1-N
CB2-E
M
M
CB3
NORMAL SUPPLY 1
NORMAL SUPPLY 2
CB1-N
CB2-N
M
M
CB3
CB3
M
NON PRIORITY
LOADS
M
NON PRIORITY
LOADS
M
NON PRIORITY
LOADS
Note: Use auxiliary voltage of 110-130V AC or 220-240V AC.
ABB Catalogue | 1SDC200023D0201 | 8/41
Emax2_cap08.indd 41
12/04/2013 14:05:58
Electrical diagrams
Power Controller
103) Ekip Signalling 10K
103
* A)
+
* Q)
TO W3-W4
24/48 VDC
EKIP LINK
+
110-240 VAC/DC
K101
A13
O101
O102
O103
K104
K105
O104
K106
K107
O105
K108
K109
O106
K110
K111
O107
K112
K113
O108
K114
K115
O109
K116
K117
K119
O110
H101
I101
K118
K120
H103
I102
H102
H104
H105
H107
I103
I104
H106
H109
I105
H108
H111
I106
H110
H112
H113
I107
H115
I108
H114
H117
I109
H116
H119
I110
H118
H120
H121
VDC+ VDC-
L+
L-
W3 W4
W13
I111
H122
EKIP SIGNALLING 10K
1SDC200655F001
K102
K103
RJ45
* C)
-
8
104) Ekip Multimeter
104
K51
EKIP
* A)
XV
X
K1
K2
K1
K2
XV
X
W3
W4
W3
W4
* Q)
+
24/48 VDC
+
110-240 VAC/DC
-
VDC+
VDC-
L+
L-
ODC+ ODC-
W3 W4
A15
1SDC200656F001
EKIP MULTIMETER
8/42 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 42
12/04/2013 14:05:58
105) Application diagram for Ekip Touch, Hi-Touch, G Touch, G Hi-Touch with Power Controller function
105
Q2 - EMAX 2
Q1 - EMAX 2 WITH EKIP POWER CONTROLLER
+
~
Q3 - TMAX XT + MOE
+
~
+
~
JG2-XE3
XV 96
98
X
12
14
XV 12
14
X
XV 11
X
95
K51
SIGN
U1
XV 05
JG2-XE3
K11
K13
H11
H12
HC1
XV K11
K13
H11
H12
HC1
O 11
O 12
I 11
I 12
XV U1
X
K1
K2
XV
K1
K2
K51
SUPPLY
XV K12
X
F1
X
C11
X
C1
XV C11
XV C1
YO
YC
K12
X
K3
K4
K5
K6
H1
H2
H3
H4
HC
XV K3
K4
K5
K6
H1
H2
H3
H4
HC
K51 O 01
SIGN
O 02
O 03
X
K14
X
W3
O 04
I 01
I 02
I 03
I 04
XD1 12
14
XV 12
14
JB1-XD2
JA1-XD2
Q/1
C11
JA1-XD2
A1
XV A1
XV C11
X
K7
K8
K9
K10
K8
K9
K10
XV HC
X
HC
XD1 11
HC
HC
A17
W4
MOE
K14
M
M
YC
XV U2
(A) (B)
XV U2
X
XV C12
X
U2
X
JA1-XD2
(LOCAL BUS)
XV C2
C12
U1
XV U1
XV 11
XV K7
XV W4
XV W3
S33M/1
05
11
X
X
08
08
ENERGY
CLOCK METER
XV 95
06
XV 06
S51
Q/1
S51
Ekip Signalling 4K
98
Ekip Supply 110-240VAC/DC
Ekip Supply 24-48VDC
96
Ekip Signalling 2K-1
X
C2
U2
R1
~
~
1SDC200657ENF001
~
Q2 - EMAX 2
Q1 - EMAX 2 WITH EKIP POWER CONTROLLER
+
~
105
Q3 - TMAX XT + MOE
+
~
+
~
JG2-XE3
XV
X
XV
96
98
96
98
8
06
08
06
08
S51
S51
XV
95
X
K1
K2
X
95
XV
K1
K2
K51
SUPPLY
X
U1
XV
U1
S33M/1
C11
X
C1
XV
C11
XV
C1
M
YO
XV
W3
XV
W4
X
W3
X
W4
XV
U2
XV
C12
XV
C2
X
U2
X
C12
X
C2
12
14
XD1
12
14
XV
12
14
JA1-XD2
XV
C11
U1
XV
U1
12
14
MOE
M
Q/1
YC
XV
JA1-XD2
XV
11
XV
11
X
11
XD1
11
U2
U2
R1
~
~
A1
A17
X
Q/1
C11
A1
XV
XV
YC
05
JB1-XD2
JA1-XD2
(LOCAL BUS)
F1
X
05
JG2-XE3
Ekip Supply 110-240VAC/DC
Ekip Supply 24-48VDC
XV
~
+
~
A13
O101
K103
O102
K102
H101
I101
K104
H102
H121
W13
W3 W4
VDC+
VDC-
L+
L-
I111
H122
H103
I102
EKIP SIGNALLING 10K
H104
K105
O103
K107
O104
K106
K108
1SDC200658ENF001
K101
RJ45
ENERGY
CLOCK METER
~
ABB Catalogue | 1SDC200023D0201 | 8/43
Emax2_cap08.indd 43
12/04/2013 14:05:59
Electrical diagrams
Power Controller
105
Q4 - EMAX 2 MS
Q2 - EMAX 2
+
~
Q1 - EMAX 2 WITH EKIP POWER CONTROLLER
+
~
+
~
+
~
ENERGY
CLOCK METER
+
~
Q3 - TMAX XT + MOE
JG2-XE3
XV
06
08
06
08
S51
K2
XV
K1
K2
Ekip Supply 110-240VAC/DC
Ekip Supply 24-48VDC
K51
SIGN
K51
SUPPLY
X
X
XV
C13
XV
C3
S33M/1
F1
M
X
C11
X
C1
XV
C11
XV
C1
YO
X
12
14
XV
12
14
YC
XV
U2
XV
C12
XV
C2
X
U2
X
C12
X
C2
K51
YO
F1
M
Q/1
XV
11
X
11
K51
YC
YO
YC
XV
U2
XV
C12
XV
C2
X
U2
X
C12
X
C2
S75I/5
K51
COM
W13
XV
W3
XV
W4
X
W3
X
W4
H11
H12
HC1
H11
H12
HC1
O 11
O 12
XV K13
X
K13
I 11
K14
K2
XV
K1
K2
S75I/5
K51
COM
(A) (B)
(LOCAL BUS)
JG2-XE3
XV
W3
XV
W4
X
W3
X
W4
05
JB1-XD2
JA1-XD2
C11
JA1-XD2
A1
XV
A1
XV
C11
U1
XV
U1
A17
XD1
12
14
XV
12
14
MOE
M
Q/1
(A) (B)
W13
05
YC
XV
JA1-XD2
(LOCAL BUS)
XV
11
XD1
11
U2
U2
R1
n
~
~
RJ45
BUS 1
~
RJ45
BUS 1
~
XV
K1
K51
SUPPLY
K14
n
~
I 12
X
Ekip Link
U1
Ekip Com Actuator
S33M/1
X
XV
C3
K12
K12
RJ45
U1
C13
Ekip Link
XV
U1
RJ45
X
U1
K11
XV K11
Ekip Signalling 2K-1
K1
Ekip Supply 110-240VAC/DC
Ekip Supply 24-48VDC
X
X
A21
RJ45
ETHERNET SWITCH
+
~
8
O101
K103
O102
K102
H101
W13
W3 W4
VDC+ VDC-
L+
L-
I101
K104
H102
H103
I102
EKIP SIGNALLING 10K
H104
K105
O103
K107
O104
K106
K108
1SDC200659ENF001
K101
A13
RJ45
~
8/44 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap08.indd 44
12/04/2013 14:05:59
Ordering codes
Instructions for ordering
Ordering examples
9/2
General information
9/5
Automatic circuit-breakers
Fixed version for power distribution
9/6
Withdrawable version for power distribution
9/21
Fixed version for generators
9/35
Withdrawable version for generators
9/40
Switch-disconnectors
Fixed version
9/45
Withdrawable version
9/48
Version for applications up to 1150V AC
9/50
Fixed version for applications up to 1000V DC
9/51
Withdrawable version for applications up to 1000V DC
9/52
Derived versions
Sectionalizing truck
9/53
Earthing truck
9/53
Earthing switch with making capacity
9/53
Fixed parts
9/54
9
Accessories
Electrical accessories
9/55
Mechanical accessories
9/58
Mechanical interlock
9/61
Ekip modules
9/62
Terminals
9/65
ABB Catalogue | 1SDC200023D0201 | 9/1
Emax2_cap09.indd 1
15/04/2013 18:00:42
Instructions for ordering
Ordering examples
Standard version Emax 2 series circuit-breakers are identified by means of commercial codes that can be accessorized.
Ordering examples
– Terminal kit codes (other than standard supply) for fixed circuit-breaker or for fixed part of withdrawable circuit-breaker.
The codes refer to 3 or 4 pieces (for mounting on top or bottom terminals).
To convert a complete circuit-breaker, 1 kit for upper terminals and 1 kit for lower terminals must be specified in the order.
Example no. 1
Emax E2.2N 3 poles fixed with vertical rear terminals (VR)
1SDA071066R1
E2.2N 2500 Ekip Touch LSIG 3p F HR
1SDA074009R1
Kit VR Sup E2.2 Iu=2500 3pcs INST
1SDA074011R1
Kit VR Inf E2.2 Iu=2500 3pcs INST
Example no. 2
Emax E1.2N 4 poles fixed with upper vertical rear (VR) and front (F) terminals
(standard supply)
1SDA071513R1
E1.2N 1600 Ekip Dip LSIG 4p F F
1SDA073986R1
Kit VR Upper E1.2 F 4pcs INST
Example no. 3
Emax E4.2H 3 poles fixed with upper front terminals (F) and adjustable rear bottom
vertical (VR) terminals
1SDA071169R1
E4.2H 3200 Ekip Hi-Touch LSIG 3p F HR
1SDA074126R1
Kit F upper E4.2 F 3pcs INST
1SDA074017R1
Kit VR lower E4.2 Iu=3200 3pcs INST
Example no. 4
9
Emax E2.2 2000A 3 poles fixed part with spread upper vertical terminals (SVR) and
rear bottom adjustable horizontal (HR) terminals (standard supply)
1SDA073909R1
E2.2 W FP Iu=2000 3p HR HR
1SDA074057R1
Kit SVR upper E2.2 Iu=2000 3pcs INST
– Rating Plug for lower values than rated current.
Rating plug installed on the circuit-breaker enables to obtain lower current values than rated current.
Example no. 5
Emax E2.2S 2500 4 poles fixed In=1600A
1SDA071706R1
E2.2S 2500 Ekip Touch LSIG 4p F HR
1SDA074266R1
Rating Plug 1600 E1.2..E6.2 INST
– Special version for rated service voltages up to 1150V AC.
Upgrade kits for SACE Emax 2 circuit-breakers enables the version for applications up to 1150V AC.
Example no. 6
Emax E6.2X 6300 4 poles fixed for applications up to 1150V AC
1SDA071949R1
E6.2X 6300 Ekip HI-Touch LSIG 4p F HR
1SDA074347R1
E6.2X/E Iu=6300 Upgrade Kit 1150V AC 4p
9/2 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 2
15/04/2013 18:00:42
– Ordering for Ekip modules.
Ekip Supply module enables Ekip Com, Ekip Link, Ekip 2K, Ekip Syncrocheck cartridge modules to be installed.
In addition to Ekip Supply modules, up to 3 cartridge modules can be installed on E2.2, E4.2 and E6.2 and up to 2 modules
on E1.2.
Ekip Fan module can be installed as an alternative of Ekip Supply only on withdrawable version of E2.2, E4.2 and E6.2.
In addition to Ekip Fan, up to 2 modules can be installed.
Example no. 7
Emax E4.2H 3 poles fixed with modules: Ekip Supply, Ekip Com Modbus TCP,
Ekip Signalling 2K-1, Ekip Com Modbus TCP Redundant and Ekip Signalling 4K
1SDA071169R1
E4.2H 3200 Ekip Hi-Touch LSIG 3p F HR
1SDA074173R1
Ekip Supply 24-48V DC E1.2..E6.2
1SDA074151R1
Ekip Com Modbus TCP E1.2..E6.2
1SDA074158R1
Ekip Com R Modbus TCP E1.2..E6.2
1SDA074167R1
Ekip Sign. 2K-1 E1.2..E6.2
1SDA074170R1
Ekip Sign. 4K E2.2..E6.2
Example no. 8
Emax E4.2H 3 poles fixed with modules: Ekip Fan, Ekip Com EtherNet/IP,
Ekip Com Modbus RS-485 and Ekip Measuring Pro
1SDA071166R1
E4.2H 3200 Ekip Touch LSIG 3p F HR
1SDA074174R1
Ekip Fan 24VDC E2.2..E6.2
1SDA074155R1
Ekip Com EtherNet/IP E1.2..E6.2
1SDA074150R1
Ekip Com Modbus RS-485 E1.2..E6.2
1SDA074189R1
Ekip Measuring Pro E4.2
9
Example no. 9
Emax E1.2N 4 poles fixed with modules: Ekip Supply, Ekip Link
1SDA071513R1
E1.2N 1600 Ekip Dip LSIG 4p F F
1SDA074172R1
Ekip Supply 110-240V AC/DC E1.2..E6.2
1SDA074163R1
Ekip Link E1.2..E6.2
– Ordering for electrical accessories.
All the accessories are available. In particular, up to 3 coils can be ordered for E1.2, whereas up to 4 coils for E2.2,
E4.2 and E6.2.
Example no. 10
Emax E2.2S 3 poles withdrawable with accessories: opening release, closing
release, motor for automatic charging of the springs, second opening release
1SDA072395R1
E2.2S 2000 Ekip Touch LSi LSIG 3p WMP
1SDA073674R1
YO E1.2..E6.2 220-240V AC/DC
1SDA073687R1
YC E1.2..E6.2 220-240V AC/DC
1SDA073725R1
M E2.2...E6.2 220-250V AC/DC
1SDA073674R1
YO E1.2..E6.2 220-240V AC/DC
– Ordering for key locks.
Example no. 11
Emax E2.2N 3 poles with double key lock in racked-in / test / racked-out position,
using different keys
1SDA071066R1
E2.2N 2500 Ekip Touch LSIG 3p F HR
1SDA073806R1
KLP-D Bl. Racked in/out E2.2...E6.2 1st key
1SDA073812R1
KLP-D Bl. Racked in/out E2.2...E6.2 2nd key
ABB Catalogue | 1SDC200023D0201 | 9/3
Emax2_cap09.indd 3
15/04/2013 18:00:42
Instructions for ordering
Ordering examples
– Ordering for mechanical Interlocks.
Interlocks have several strategy configuration, suitable for fixed circuit-breakers and withdrawable circuit-breakers.
Each configuration requires different groups:
- Cables, select one Kit for strategy A / B / C / D. The cables must be ordered on fixed circuit-breaker or fixed part of
withdrawable circuit-breaker.
- Lever, required only for E2.2, E4.2 and E6.2. These lever must be mounted on fixed circuit-breaker or on mobile part of
withdrawable circuit-breaker.
- Support, installed on fixed circuit-breaker or on fixed part of withdrawable circuit-breaker. This support is mounted on the
external right side of the circuit-breaker.
Example no. 12
Interlock between two fixed circuit-breakers: E1.2 and E2.2
E1.2 Fixed circuit-breaker
E2.2 Fixed circuit-breaker
Cables [Group 1]: 1 Item
Lever [Group 2]: 1 Item
Support [Group 3]: 1 Item
Support [Group 3]: 1 Item
Example no. 13
Interlock between three fixed circuit-breakers: one E2.2 and two E4.2
E2.2 Fixed circuit-breaker
E4.2 Fixed circuit-breaker
E4.2 Fixed circuit-breaker
Cables [Group 1]: 1 Item
Lever [Group 2]: 1 Item
Lever [Group 2]: 1 Item
Lever [Group 2]: 1 Item
Support [Group 3]: 1 Item
Support [Group 3]: 1 Item
Support [Group 3]: 1 Item
Example no. 14
Interlock between two withdrawable circuit-breakers: E1.2 and E2.2
9
E1.2 Fixed Part
E2.2 Mobile Part
Cables [Group 1]: 1 Item
Lever [Group 2]: 1 Item
Support [Group 4]: 1 Item
+
E2.2 Fixed Part
Support [Group 4]: 1 Item
Example no. 15
Interlock between three withdrawable circuit-breakers: one E2.2 and two E4.2
E2.2 Mobile Part
E4.2 Mobile Part
E4.2 Mobile Part
Lever [Group 2]: 1 Item
Lever [Group 2]: 1 Item
Lever [Group 2]: 1 Item
E2.2 Fixed Part
E4.2 Fixed Part
E4.2 Fixed Part
Cables [Group 1]: 1 Item
Support [Group 4]: 1 Item
Support [Group 4]: 1 Item
+
Support [Group 4]: 1 Item
9/4 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 4
15/04/2013 18:00:42
General informations
Abbreviations used for the description of the product
Versions and terminals
F
Fixed circuit-breaker
W
Withdrawable circuit-breaker
MP
Mobile part of withdrawable circuit-breaker
FP
Fixed part of withdrawable circuit-breaker
Iu
Rated uninterrupted current
In
Rated current of the rating plug
Icu
Rated ultimate short-circuit breaking capacity
Icw
Rated short-time withstand current
/MS
Switch-disconnector
/E
Circuit-breakers for 1150V applications
/f
Four-pole circuit-breakers with neutral pole at 100%
CS
Sectionalizing truck
MT
Earthing truck
MTP
Earthing switch with making capacity
HR VR
Rear orientable terminals
SHR
Horizontal rear spread terminals
VHR
Vertical rear spread terminals
F
Front terminals
FL
Flat terminals
EF
Extended front terminals
ES
Front spread terminals
Fc CuAl
Terminals for cables
9
Protection trip units and functions
Ekip Dip
Protection trip unit for power distribution
Ekip Touch
Measurement and protection trip unit for power distribution
Ekip Hi Touch
Measurement and protection trip unit and network analyzer for power distribution
Ekip G Touch
Measurement and protection trip unit for generators
Ekip G Hi-Touch
Measurement and protection trip unit and protection network analyzer for generators
L
Overload protection
S
Protection against selective short circuit
I
Protection against instantaneous short circuit
G
Earth fault protection
Rc
Residual current protection
Power Controller
Load management function
ABB Catalogue | 1SDC200023D0201 | 9/5
Emax2_cap09.indd 5
15/04/2013 18:00:42
Automatic circuit-breakers
Fixed version for power distribution
1SDC200661F001
SACE Emax E1.2B • Front terminals (F)
Size
E1.2B
Iu
630
800
1000
Icu
Icw
(440 V) (1s)
Type
42
42
42
42
42
42
9
1250
1600
42
42
42
42
3 Poles
4 Poles
Code
Code
E1.2B 630 Ekip Dip LI
1SDA070701R1
1SDA071331R1
E1.2B 630 Ekip Dip LSI
1SDA070702R1
1SDA071332R1
E1.2B 630 Ekip Dip LSIG
1SDA070703R1
1SDA071333R1
E1.2B 630 Ekip Touch LI
1SDA070704R1
1SDA071334R1
E1.2B 630 Ekip Touch LSI
1SDA070705R1
1SDA071335R1
E1.2B 630 Ekip Touch LSIG
1SDA070706R1
1SDA071336R1
E1.2B 630 Ekip Hi-Touch LSI
1SDA070708R1
1SDA071338R1
E1.2B 630 Ekip Hi-Touch LSIG
1SDA070709R1
1SDA071339R1
E1.2B 800 Ekip Dip LI
1SDA070741R1
1SDA071371R1
E1.2B 800 Ekip Dip LSI
1SDA070742R1
1SDA071372R1
E1.2B 800 Ekip Dip LSIG
1SDA070743R1
1SDA071373R1
E1.2B 800 Ekip Touch LI
1SDA070744R1
1SDA071374R1
E1.2B 800 Ekip Touch LSI
1SDA070745R1
1SDA071375R1
E1.2B 800 Ekip Touch LSIG
1SDA070746R1
1SDA071376R1
E1.2B 800 Ekip Hi-Touch LSI
1SDA070748R1
1SDA071378R1
E1.2B 800 Ekip Hi-Touch LSIG
1SDA070749R1
1SDA071379R1
E1.2B 1000 Ekip Dip LI
1SDA070781R1
1SDA071411R1
E1.2B 1000 Ekip Dip LSI
1SDA070782R1
1SDA071412R1
E1.2B 1000 Ekip Dip LSIG
1SDA070783R1
1SDA071413R1
E1.2B 1000 Ekip Touch LI
1SDA070784R1
1SDA071414R1
E1.2B 1000 Ekip Touch LSI
1SDA070785R1
1SDA071415R1
E1.2B 1000 Ekip Touch LSIG
1SDA070786R1
1SDA071416R1
E1.2B 1000 Ekip Hi-Touch LSI
1SDA070788R1
1SDA071418R1
E1.2B 1000 Ekip Hi-Touch LSIG
1SDA070789R1
1SDA071419R1
E1.2B 1250 Ekip Dip LI
1SDA070821R1
1SDA071451R1
E1.2B 1250 Ekip Dip LSI
1SDA070822R1
1SDA071452R1
E1.2B 1250 Ekip Dip LSIG
1SDA070823R1
1SDA071453R1
E1.2B 1250 Ekip Touch LI
1SDA070824R1
1SDA071454R1
E1.2B 1250 Ekip Touch LSI
1SDA070825R1
1SDA071455R1
E1.2B 1250 Ekip Touch LSIG
1SDA070826R1
1SDA071456R1
E1.2B 1250 Ekip Hi-Touch LSI
1SDA070828R1
1SDA071458R1
E1.2B 1250 Ekip Hi-Touch LSIG
1SDA070829R1
1SDA071459R1
E1.2B 1600 Ekip Dip LI
1SDA070861R1
1SDA071491R1
E1.2B 1600 Ekip Dip LSI
1SDA070862R1
1SDA071492R1
E1.2B 1600 Ekip Dip LSIG
1SDA070863R1
1SDA071493R1
E1.2B 1600 Ekip Touch LI
1SDA070864R1
1SDA071494R1
E1.2B 1600 Ekip Touch LSI
1SDA070865R1
1SDA071495R1
E1.2B 1600 Ekip Touch LSIG
1SDA070866R1
1SDA071496R1
E1.2B 1600 Ekip Hi-Touch LSI
1SDA070868R1
1SDA071498R1
E1.2B 1600 Ekip Hi-Touch LSIG
1SDA070869R1
1SDA071499R1
9/6 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 6
15/04/2013 18:00:42
1SDC200661F001
SACE Emax E1.2C • Front terminals (F)
Size
E1.2C
Iu
630
800
1000
1250
1600
Icu
Icw
(440 V) (1s)
Type
50
50
50
50
50
42
42
42
42
42
3 Poles
4 Poles
Code
Code
E1.2C 630 Ekip Dip LI
1SDA070711R1
1SDA071341R1
E1.2C 630 Ekip Dip LSI
1SDA070712R1
1SDA071342R1
E1.2C 630 Ekip Dip LSIG
1SDA070713R1
1SDA071343R1
E1.2C 630 Ekip Touch LI
1SDA070714R1
1SDA071344R1
E1.2C 630 Ekip Touch LSI
1SDA070715R1
1SDA071345R1
E1.2C 630 Ekip Touch LSIG
1SDA070716R1
1SDA071346R1
E1.2C 630 Ekip Hi-Touch LSI
1SDA070718R1
1SDA071348R1
E1.2C 630 Ekip Hi-Touch LSIG
1SDA070719R1
1SDA071349R1
E1.2C 800 Ekip Dip LI
1SDA070751R1
1SDA071381R1
E1.2C 800 Ekip Dip LSI
1SDA070752R1
1SDA071382R1
E1.2C 800 Ekip Dip LSIG
1SDA070753R1
1SDA071383R1
E1.2C 800 Ekip Touch LI
1SDA070754R1
1SDA071384R1
E1.2C 800 Ekip Touch LSI
1SDA070755R1
1SDA071385R1
E1.2C 800 Ekip Touch LSIG
1SDA070756R1
1SDA071386R1
E1.2C 800 Ekip Hi-Touch LSI
1SDA070758R1
1SDA071388R1
E1.2C 800 Ekip Hi-Touch LSIG
1SDA070759R1
1SDA071389R1
E1.2C 1000 Ekip Dip LI
1SDA070791R1
1SDA071421R1
E1.2C 1000 Ekip Dip LSI
1SDA070792R1
1SDA071422R1
E1.2C 1000 Ekip Dip LSIG
1SDA070793R1
1SDA071423R1
E1.2C 1000 Ekip Touch LI
1SDA070794R1
1SDA071424R1
E1.2C 1000 Ekip Touch LSI
1SDA070795R1
1SDA071425R1
E1.2C 1000 Ekip Touch LSIG
1SDA070796R1
1SDA071426R1
E1.2C 1000 Ekip Hi-Touch LSI
1SDA070798R1
1SDA071428R1
E1.2C 1000 Ekip Hi-Touch LSIG
1SDA070799R1
1SDA071429R1
E1.2C 1250 Ekip Dip LI
1SDA070831R1
1SDA071461R1
E1.2C 1250 Ekip Dip LSI
1SDA070832R1
1SDA071462R1
E1.2C 1250 Ekip Dip LSIG
1SDA070833R1
1SDA071463R1
E1.2C 1250 Ekip Touch LI
1SDA070834R1
1SDA071464R1
E1.2C 1250 Ekip Touch LSI
1SDA070835R1
1SDA071465R1
E1.2C 1250 Ekip Touch LSIG
1SDA070836R1
1SDA071466R1
E1.2C 1250 Ekip Hi-Touch LSI
1SDA070838R1
1SDA071468R1
E1.2C 1250 Ekip Hi-Touch LSIG
1SDA070839R1
1SDA071469R1
E1.2C 1600 Ekip Dip LI
1SDA070871R1
1SDA071501R1
E1.2C 1600 Ekip Dip LSI
1SDA070872R1
1SDA071502R1
E1.2C 1600 Ekip Dip LSIG
1SDA070873R1
1SDA071503R1
E1.2C 1600 Ekip Touch LI
1SDA070874R1
1SDA071504R1
E1.2C 1600 Ekip Touch LSI
1SDA070875R1
1SDA071505R1
E1.2C 1600 Ekip Touch LSIG
1SDA070876R1
1SDA071506R1
E1.2C 1600 Ekip Hi-Touch LSI
1SDA070878R1
1SDA071508R1
E1.2C 1600 Ekip Hi-Touch LSIG
1SDA070879R1
1SDA071509R1
9
ABB Catalogue | 1SDC200023D0201 | 9/7
Emax2_cap09.indd 7
15/04/2013 18:00:43
Automatic circuit-breakers
Fixed version for power distribution
1SDC200661F001
SACE Emax E1.2N • Front terminals (F)
Size
E1.2N
Iu
250
630
800
Icu
Icw
(440 V) (1s)
Type
66
66
66
50
50
50
9
1000
1250
1600
66
66
66
50
50
50
3 Poles
4 Poles
Code
Code
E1.2N 250 Ekip Dip LI
1SDA070691R1
1SDA071321R1
E1.2N 250 Ekip Dip LSI
1SDA070692R1
1SDA071322R1
E1.2N 250 Ekip Dip LSIG
1SDA070693R1
1SDA071323R1
E1.2N 250 Ekip Touch LI
1SDA070694R1
1SDA071324R1
E1.2N 250 Ekip Touch LSI
1SDA070695R1
1SDA071325R1
E1.2N 250 Ekip Touch LSIG
1SDA070696R1
1SDA071326R1
E1.2N 250 Ekip Hi-Touch LSI
1SDA070698R1
1SDA071328R1
E1.2N 250 Ekip Hi-Touch LSIG
1SDA070699R1
1SDA071329R1
E1.2N 630 Ekip Dip LI
1SDA070721R1
1SDA071351R1
E1.2N 630 Ekip Dip LSI
1SDA070722R1
1SDA071352R1
E1.2N 630 Ekip Dip LSIG
1SDA070723R1
1SDA071353R1
E1.2N 630 Ekip Touch LI
1SDA070724R1
1SDA071354R1
E1.2N 630 Ekip Touch LSI
1SDA070725R1
1SDA071355R1
E1.2N 630 Ekip Touch LSIG
1SDA070726R1
1SDA071356R1
E1.2N 630 Ekip Hi-Touch LSI
1SDA070728R1
1SDA071358R1
E1.2N 630 Ekip Hi-Touch LSIG
1SDA070729R1
1SDA071359R1
E1.2N 800 Ekip Dip LI
1SDA070761R1
1SDA071391R1
E1.2N 800 Ekip Dip LSI
1SDA070762R1
1SDA071392R1
E1.2N 800 Ekip Dip LSIG
1SDA070763R1
1SDA071393R1
E1.2N 800 Ekip Touch LI
1SDA070764R1
1SDA071394R1
E1.2N 800 Ekip Touch LSI
1SDA070765R1
1SDA071395R1
E1.2N 800 Ekip Touch LSIG
1SDA070766R1
1SDA071396R1
E1.2N 800 Ekip Hi-Touch LSI
1SDA070768R1
1SDA071398R1
E1.2N 800 Ekip Hi-Touch LSIG
1SDA070769R1
1SDA071399R1
E1.2N 1000 Ekip Dip LI
1SDA070801R1
1SDA071431R1
E1.2N 1000 Ekip Dip LSI
1SDA070802R1
1SDA071432R1
E1.2N 1000 Ekip Dip LSIG
1SDA070803R1
1SDA071433R1
E1.2N 1000 Ekip Touch LI
1SDA070804R1
1SDA071434R1
E1.2N 1000 Ekip Touch LSI
1SDA070805R1
1SDA071435R1
E1.2N 1000 Ekip Touch LSIG
1SDA070806R1
1SDA071436R1
E1.2N 1000 Ekip Hi-Touch LSI
1SDA070808R1
1SDA071438R1
E1.2N 1000 Ekip Hi-Touch LSIG
1SDA070809R1
1SDA071439R1
E1.2N 1250 Ekip Dip LI
1SDA070841R1
1SDA071471R1
E1.2N 1250 Ekip Dip LSI
1SDA070842R1
1SDA071472R1
E1.2N 1250 Ekip Dip LSIG
1SDA070843R1
1SDA071473R1
E1.2N 1250 Ekip Touch LI
1SDA070844R1
1SDA071474R1
E1.2N 1250 Ekip Touch LSI
1SDA070845R1
1SDA071475R1
E1.2N 1250 Ekip Touch LSIG
1SDA070846R1
1SDA071476R1
E1.2N 1250 Ekip Hi-Touch LSI
1SDA070848R1
1SDA071478R1
E1.2N 1250 Ekip Hi-Touch LSIG
1SDA070849R1
1SDA071479R1
E1.2N 1600 Ekip Dip LI
1SDA070881R1
1SDA071511R1
E1.2N 1600 Ekip Dip LSI
1SDA070882R1
1SDA071512R1
E1.2N 1600 Ekip Dip LSIG
1SDA070883R1
1SDA071513R1
E1.2N 1600 Ekip Touch LI
1SDA070884R1
1SDA071514R1
E1.2N 1600 Ekip Touch LSI
1SDA070885R1
1SDA071515R1
E1.2N 1600 Ekip Touch LSIG
1SDA070886R1
1SDA071516R1
E1.2N 1600 Ekip Hi-Touch LSI
1SDA070888R1
1SDA071518R1
E1.2N 1600 Ekip Hi-Touch LSIG
1SDA070889R1
1SDA071519R1
9/8 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 8
15/04/2013 18:00:43
1SDC200661F001
SACE Emax E1.2L • Front terminals (F)
Size
E1.2L
Iu
630
800
1000
1250
Icu
Icw
(440 V) (1s)
Type
130
130
130
130
15
15
15
15
3 Poles
4 Poles
Code
Code
E1.2L 630 Ekip Dip LI
1SDA070731R1
1SDA071361R1
E1.2L 630 Ekip Dip LSI
1SDA070732R1
1SDA071362R1
E1.2L 630 Ekip Dip LSIG
1SDA070733R1
1SDA071363R1
E1.2L 630 Ekip Touch LI
1SDA070734R1
1SDA071364R1
E1.2L 630 Ekip Touch LSI
1SDA070735R1
1SDA071365R1
E1.2L 630 Ekip Touch LSIG
1SDA070736R1
1SDA071366R1
E1.2L 630 Ekip Hi-Touch LSI
1SDA070738R1
1SDA071368R1
E1.2L 630 Ekip Hi-Touch LSIG
1SDA070739R1
1SDA071369R1
E1.2L 800 Ekip Dip LI
1SDA070771R1
1SDA071401R1
E1.2L 800 Ekip Dip LSI
1SDA070772R1
1SDA071402R1
E1.2L 800 Ekip Dip LSIG
1SDA070773R1
1SDA071403R1
E1.2L 800 Ekip Touch LI
1SDA070774R1
1SDA071404R1
E1.2L 800 Ekip Touch LSI
1SDA070775R1
1SDA071405R1
E1.2L 800 Ekip Touch LSIG
1SDA070776R1
1SDA071406R1
E1.2L 800 Ekip Hi-Touch LSI
1SDA070778R1
1SDA071408R1
E1.2L 800 Ekip Hi-Touch LSIG
1SDA070779R1
1SDA071409R1
E1.2L 1000 Ekip Dip LI
1SDA070811R1
1SDA071441R1
E1.2L 1000 Ekip Dip LSI
1SDA070812R1
1SDA071442R1
E1.2L 1000 Ekip Dip LSIG
1SDA070813R1
1SDA071443R1
E1.2L 1000 Ekip Touch LI
1SDA070814R1
1SDA071444R1
E1.2L 1000 Ekip Touch LSI
1SDA070815R1
1SDA071445R1
E1.2L 1000 Ekip Touch LSIG
1SDA070816R1
1SDA071446R1
E1.2L 1000 Ekip Hi-Touch LSI
1SDA070818R1
1SDA071448R1
E1.2L 1000 Ekip Hi-Touch LSIG
1SDA070819R1
1SDA071449R1
E1.2L 1250 Ekip Dip LI
1SDA070851R1
1SDA071481R1
E1.2L 1250 Ekip Dip LSI
1SDA070852R1
1SDA071482R1
E1.2L 1250 Ekip Dip LSIG
1SDA070853R1
1SDA071483R1
E1.2L 1250 Ekip Touch LI
1SDA070854R1
1SDA071484R1
E1.2L 1250 Ekip Touch LSI
1SDA070855R1
1SDA071485R1
E1.2L 1250 Ekip Touch LSIG
1SDA070856R1
1SDA071486R1
E1.2L 1250 Ekip Hi-Touch LSI
1SDA070858R1
1SDA071488R1
E1.2L 1250 Ekip Hi-Touch LSIG
1SDA070859R1
1SDA071489R1
9
ABB Catalogue | 1SDC200023D0201 | 9/9
Emax2_cap09.indd 9
15/04/2013 18:00:43
Automatic circuit-breakers
Fixed version for power distribution
1SDC200662F001
SACE Emax E2.2B • Orientable rear terminals (HR)
Size
E2.2B
Iu
1600
2000
Icu
Icw
(440 V) (1s)
Type
42
42
42
42
3 Poles
4 Poles
Code
Code
E2.2B 1600 Ekip Dip LI
1SDA070981R1
1SDA071611R1
E2.2B 1600 Ekip Dip LSI
1SDA070982R1
1SDA071612R1
E2.2B 1600 Ekip Dip LSIG
1SDA070983R1
1SDA071613R1
E2.2B 1600 Ekip Touch LI
1SDA070984R1
1SDA071614R1
E2.2B 1600 Ekip Touch LSI
1SDA070985R1
1SDA071615R1
E2.2B 1600 Ekip Touch LSIG
1SDA070986R1
1SDA071616R1
E2.2B 1600 Ekip Hi-Touch LSI
1SDA070988R1
1SDA071618R1
E2.2B 1600 Ekip Hi-Touch LSIG
1SDA070989R1
1SDA071619R1
E2.2B 2000 Ekip Dip LI
1SDA071021R1
1SDA071651R1
E2.2B 2000 Ekip Dip LSI
1SDA071022R1
1SDA071652R1
E2.2B 2000 Ekip Dip LSIG
1SDA071023R1
1SDA071653R1
E2.2B 2000 Ekip Touch LI
1SDA071024R1
1SDA071654R1
E2.2B 2000 Ekip Touch LSI
1SDA071025R1
1SDA071655R1
E2.2B 2000 Ekip Touch LSIG
1SDA071026R1
1SDA071656R1
E2.2B 2000 Ekip Hi-Touch LSI
1SDA071028R1
1SDA071658R1
E2.2B 2000 Ekip Hi-Touch LSIG
1SDA071029R1
1SDA071659R1
9
9/10 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 10
15/04/2013 18:00:44
1SDC200662F001
SACE Emax E2.2N • Orientable rear terminals (HR)
Size
E2.2N
Iu
800
1000
1250
1600
2000
2500
Icu
Icw
(440 V) (1s)
Type
66
66
66
66
66
66
66
66
66
66
66
66
3 Poles
4 Poles
Code
Code
E2.2N 800 Ekip Dip LI
1SDA070891R1
1SDA071521R1
E2.2N 800 Ekip Dip LSI
1SDA070892R1
1SDA071522R1
E2.2N 800 Ekip Dip LSIG
1SDA070893R1
1SDA071523R1
E2.2N 800 Ekip Touch LI
1SDA070894R1
1SDA071524R1
E2.2N 800 Ekip Touch LSI
1SDA070895R1
1SDA071525R1
E2.2N 800 Ekip Touch LSIG
1SDA070896R1
1SDA071526R1
E2.2N 800 Ekip Hi-Touch LSI
1SDA070898R1
1SDA071528R1
E2.2N 800 Ekip Hi-Touch LSIG
1SDA070899R1
1SDA071529R1
E2.2N 1000 Ekip Dip LI
1SDA070921R1
1SDA071551R1
E2.2N 1000 Ekip Dip LSI
1SDA070922R1
1SDA071552R1
E2.2N 1000 Ekip Dip LSIG
1SDA070923R1
1SDA071553R1
E2.2N 1000 Ekip Touch LI
1SDA070924R1
1SDA071554R1
E2.2N 1000 Ekip Touch LSI
1SDA070925R1
1SDA071555R1
E2.2N 1000 Ekip Touch LSIG
1SDA070926R1
1SDA071556R1
E2.2N 1000 Ekip Hi-Touch LSI
1SDA070928R1
1SDA071558R1
E2.2N 1000 Ekip Hi-Touch LSIG
1SDA070929R1
1SDA071559R1
E2.2N 1250 Ekip Dip LI
1SDA070951R1
1SDA071581R1
E2.2N 1250 Ekip Dip LSI
1SDA070952R1
1SDA071582R1
E2.2N 1250 Ekip Dip LSIG
1SDA070953R1
1SDA071583R1
E2.2N 1250 Ekip Touch LI
1SDA070954R1
1SDA071584R1
E2.2N 1250 Ekip Touch LSI
1SDA070955R1
1SDA071585R1
E2.2N 1250 Ekip Touch LSIG
1SDA070956R1
1SDA071586R1
E2.2N 1250 Ekip Hi-Touch LSI
1SDA070958R1
1SDA071588R1
E2.2N 1250 Ekip Hi-Touch LSIG
1SDA070959R1
1SDA071589R1
E2.2N 1600 Ekip Dip LI
1SDA070991R1
1SDA071621R1
E2.2N 1600 Ekip Dip LSI
1SDA070992R1
1SDA071622R1
E2.2N 1600 Ekip Dip LSIG
1SDA070993R1
1SDA071623R1
E2.2N 1600 Ekip Touch LI
1SDA070994R1
1SDA071624R1
E2.2N 1600 Ekip Touch LSI
1SDA070995R1
1SDA071625R1
E2.2N 1600 Ekip Touch LSIG
1SDA070996R1
1SDA071626R1
E2.2N 1600 Ekip Hi-Touch LSI
1SDA070998R1
1SDA071628R1
E2.2N 1600 Ekip Hi-Touch LSIG
1SDA070999R1
1SDA071629R1
E2.2N 2000 Ekip Dip LI
1SDA071031R1
1SDA071661R1
E2.2N 2000 Ekip Dip LSI
1SDA071032R1
1SDA071662R1
E2.2N 2000 Ekip Dip LSIG
1SDA071033R1
1SDA071663R1
E2.2N 2000 Ekip Touch LI
1SDA071034R1
1SDA071664R1
E2.2N 2000 Ekip Touch LSI
1SDA071035R1
1SDA071665R1
E2.2N 2000 Ekip Touch LSIG
1SDA071036R1
1SDA071666R1
E2.2N 2000 Ekip Hi-Touch LSI
1SDA071038R1
1SDA071668R1
E2.2N 2000 Ekip Hi-Touch LSIG
1SDA071039R1
1SDA071669R1
E2.2N 2500 Ekip Dip LI
1SDA071061R1
1SDA071691R1
E2.2N 2500 Ekip Dip LSI
1SDA071062R1
1SDA071692R1
E2.2N 2500 Ekip Dip LSIG
1SDA071063R1
1SDA071693R1
E2.2N 2500 Ekip Touch LI
1SDA071064R1
1SDA071694R1
E2.2N 2500 Ekip Touch LSI
1SDA071065R1
1SDA071695R1
E2.2N 2500 Ekip Touch LSIG
1SDA071066R1
1SDA071696R1
E2.2N 2500 Ekip Hi-Touch LSI
1SDA071068R1
1SDA071698R1
E2.2N 2500 Ekip Hi-Touch LSIG
1SDA071069R1
1SDA071699R1
9
ABB Catalogue | 1SDC200023D0201 | 9/11
Emax2_cap09.indd 11
15/04/2013 18:00:44
Automatic circuit-breakers
Fixed version for power distribution
1SDC200662F001
SACE Emax E2.2S • Orientable rear terminals (HR)
Size
E2.2S
Iu
250
800
1000
Icu
Icw
(440 V) (1s)
Type
85
85
85
66
66
66
9
1250
85
66
3 Poles
4 Poles
Code
Code
E2.2S 250 Ekip Dip LI
1SDA073628R1
1SDA073638R1
E2.2S 250 Ekip Dip LSI
1SDA073629R1
1SDA073639R1
E2.2S 250 Ekip Dip LSIG
1SDA073630R1
1SDA073640R1
E2.2S 250 Ekip Touch LI
1SDA073631R1
1SDA073641R1
E2.2S 250 Ekip Touch LSI
1SDA073632R1
1SDA073642R1
E2.2S 250 Ekip Touch LSIG
1SDA073633R1
1SDA073643R1
E2.2S 250 Ekip Hi-Touch LSI
1SDA073635R1
1SDA073645R1
E2.2S 250 Ekip Hi-Touch LSIG
1SDA073636R1
1SDA073646R1
E2.2S 800 Ekip Dip LI
1SDA070901R1
1SDA071531R1
E2.2S 800 Ekip Dip LSI
1SDA070902R1
1SDA071532R1
E2.2S 800 Ekip Dip LSIG
1SDA070903R1
1SDA071533R1
E2.2S 800 Ekip Touch LI
1SDA070904R1
1SDA071534R1
E2.2S 800 Ekip Touch LSI
1SDA070905R1
1SDA071535R1
E2.2S 800 Ekip Touch LSIG
1SDA070906R1
1SDA071536R1
E2.2S 800 Ekip Hi-Touch LSI
1SDA070908R1
1SDA071538R1
E2.2S 800 Ekip Hi-Touch LSIG
1SDA070909R1
1SDA071539R1
E2.2S 1000 Ekip Dip LI
1SDA070931R1
1SDA071561R1
E2.2S 1000 Ekip Dip LSI
1SDA070932R1
1SDA071562R1
E2.2S 1000 Ekip Dip LSIG
1SDA070933R1
1SDA071563R1
E2.2S 1000 Ekip Touch LI
1SDA070934R1
1SDA071564R1
E2.2S 1000 Ekip Touch LSI
1SDA070935R1
1SDA071565R1
E2.2S 1000 Ekip Touch LSIG
1SDA070936R1
1SDA071566R1
E2.2S 1000 Ekip Hi-Touch LSI
1SDA070938R1
1SDA071568R1
E2.2S 1000 Ekip Hi-Touch LSIG
1SDA070939R1
1SDA071569R1
E2.2S 1250 Ekip Dip LI
1SDA070961R1
1SDA071591R1
E2.2S 1250 Ekip Dip LSI
1SDA070962R1
1SDA071592R1
E2.2S 1250 Ekip Dip LSIG
1SDA070963R1
1SDA071593R1
E2.2S 1250 Ekip Touch LI
1SDA070964R1
1SDA071594R1
E2.2S 1250 Ekip Touch LSI
1SDA070965R1
1SDA071595R1
E2.2S 1250 Ekip Touch LSIG
1SDA070966R1
1SDA071596R1
E2.2S 1250 Ekip Hi-Touch LSI
1SDA070968R1
1SDA071598R1
E2.2S 1250 Ekip Hi-Touch LSIG
1SDA070969R1
1SDA071599R1
9/12 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 12
15/04/2013 18:00:44
1SDC200662F001
SACE Emax E2.2S • Orientable rear terminals (HR)
Size
E2.2S
Iu
1600
2000
2500
Icu
Icw
(440 V) (1s)
Type
85
85
85
66
66
66
3 Poles
4 Poles
Code
Code
E2.2S 1600 Ekip Dip LI
1SDA071001R1
1SDA071631R1
E2.2S 1600 Ekip Dip LSI
1SDA071002R1
1SDA071632R1
E2.2S 1600 Ekip Dip LSIG
1SDA071003R1
1SDA071633R1
E2.2S 1600 Ekip Touch LI
1SDA071004R1
1SDA071634R1
E2.2S 1600 Ekip Touch LSI
1SDA071005R1
1SDA071635R1
E2.2S 1600 Ekip Touch LSIG
1SDA071006R1
1SDA071636R1
E2.2S 1600 Ekip Hi-Touch LSI
1SDA071008R1
1SDA071638R1
E2.2S 1600 Ekip Hi-Touch LSIG
1SDA071009R1
1SDA071639R1
E2.2S 2000 Ekip Dip LI
1SDA071041R1
1SDA071671R1
E2.2S 2000 Ekip Dip LSI
1SDA071042R1
1SDA071672R1
E2.2S 2000 Ekip Dip LSIG
1SDA071043R1
1SDA071673R1
E2.2S 2000 Ekip Touch LI
1SDA071044R1
1SDA071674R1
E2.2S 2000 Ekip Touch LSI
1SDA071045R1
1SDA071675R1
E2.2S 2000 Ekip Touch LSIG
1SDA071046R1
1SDA071676R1
E2.2S 2000 Ekip Hi-Touch LSI
1SDA071048R1
1SDA071678R1
E2.2S 2000 Ekip Hi-Touch LSIG
1SDA071049R1
1SDA071679R1
E2.2S 2500 Ekip Dip LI
1SDA071071R1
1SDA071701R1
E2.2S 2500 Ekip Dip LSI
1SDA071072R1
1SDA071702R1
E2.2S 2500 Ekip Dip LSIG
1SDA071073R1
1SDA071703R1
E2.2S 2500 Ekip Touch LI
1SDA071074R1
1SDA071704R1
E2.2S 2500 Ekip Touch LSI
1SDA071075R1
1SDA071705R1
E2.2S 2500 Ekip Touch LSIG
1SDA071076R1
1SDA071706R1
E2.2S 2500 Ekip Hi-Touch LSI
1SDA071078R1
1SDA071708R1
E2.2S 2500 Ekip Hi-Touch LSIG
1SDA071079R1
1SDA071709R1
9
ABB Catalogue | 1SDC200023D0201 | 9/13
Emax2_cap09.indd 13
15/04/2013 18:00:45
Automatic circuit-breakers
Fixed version for power distribution
1SDC200662F001
SACE Emax E2.2H • Orientable rear terminals (HR)
Size
E2.2H
Iu
800
1000
1250
Icu
Icw
(440 V) (1s)
Type
100
100
100
85
85
85
9
1600
2000
2500
100
100
100
85
85
85
3 Poles
4 Poles
Code
Code
E2.2H 800 Ekip Dip LI
1SDA070911R1
1SDA071541R1
E2.2H 800 Ekip Dip LSI
1SDA070912R1
1SDA071542R1
E2.2H 800 Ekip Dip LSIG
1SDA070913R1
1SDA071543R1
E2.2H 800 Ekip Touch LI
1SDA070914R1
1SDA071544R1
E2.2H 800 Ekip Touch LSI
1SDA070915R1
1SDA071545R1
E2.2H 800 Ekip Touch LSIG
1SDA070916R1
1SDA071546R1
E2.2H 800 Ekip Hi-Touch LSI
1SDA070918R1
1SDA071548R1
E2.2H 800 Ekip Hi-Touch LSIG
1SDA070919R1
1SDA071549R1
E2.2H 1000 Ekip Dip LI
1SDA070941R1
1SDA071571R1
E2.2H 1000 Ekip Dip LSI
1SDA070942R1
1SDA071572R1
E2.2H 1000 Ekip Dip LSIG
1SDA070943R1
1SDA071573R1
E2.2H 1000 Ekip Touch LI
1SDA070944R1
1SDA071574R1
E2.2H 1000 Ekip Touch LSI
1SDA070945R1
1SDA071575R1
E2.2H 1000 Ekip Touch LSIG
1SDA070946R1
1SDA071576R1
E2.2H 1000 Ekip Hi-Touch LSI
1SDA070948R1
1SDA071578R1
E2.2H 1000 Ekip Hi-Touch LSIG
1SDA070949R1
1SDA071579R1
E2.2H 1250 Ekip Dip LI
1SDA070971R1
1SDA071601R1
E2.2H 1250 Ekip Dip LSI
1SDA070972R1
1SDA071602R1
E2.2H 1250 Ekip Dip LSIG
1SDA070973R1
1SDA071603R1
E2.2H 1250 Ekip Touch LI
1SDA070974R1
1SDA071604R1
E2.2H 1250 Ekip Touch LSI
1SDA070975R1
1SDA071605R1
E2.2H 1250 Ekip Touch LSIG
1SDA070976R1
1SDA071606R1
E2.2H 1250 Ekip Hi-Touch LSI
1SDA070978R1
1SDA071608R1
E2.2H 1250 Ekip Hi-Touch LSIG
1SDA070979R1
1SDA071609R1
E2.2H 1600 Ekip Dip LI
1SDA071011R1
1SDA071641R1
E2.2H 1600 Ekip Dip LSI
1SDA071012R1
1SDA071642R1
E2.2H 1600 Ekip Dip LSIG
1SDA071013R1
1SDA071643R1
E2.2H 1600 Ekip Touch LI
1SDA071014R1
1SDA071644R1
E2.2H 1600 Ekip Touch LSI
1SDA071015R1
1SDA071645R1
E2.2H 1600 Ekip Touch LSIG
1SDA071016R1
1SDA071646R1
E2.2H 1600 Ekip Hi-Touch LSI
1SDA071018R1
1SDA071648R1
E2.2H 1600 Ekip Hi-Touch LSIG
1SDA071019R1
1SDA071649R1
E2.2H 2000 Ekip Dip LI
1SDA071051R1
1SDA071681R1
E2.2H 2000 Ekip Dip LSI
1SDA071052R1
1SDA071682R1
E2.2H 2000 Ekip Dip LSIG
1SDA071053R1
1SDA071683R1
E2.2H 2000 Ekip Touch LI
1SDA071054R1
1SDA071684R1
E2.2H 2000 Ekip Touch LSI
1SDA071055R1
1SDA071685R1
E2.2H 2000 Ekip Touch LSIG
1SDA071056R1
1SDA071686R1
E2.2H 2000 Ekip Hi-Touch LSI
1SDA071058R1
1SDA071688R1
E2.2H 2000 Ekip Hi-Touch LSIG
1SDA071059R1
1SDA071689R1
E2.2H 2500 Ekip Dip LI
1SDA071081R1
1SDA071711R1
E2.2H 2500 Ekip Dip LSI
1SDA071082R1
1SDA071712R1
E2.2H 2500 Ekip Dip LSIG
1SDA071083R1
1SDA071713R1
E2.2H 2500 Ekip Touch LI
1SDA071084R1
1SDA071714R1
E2.2H 2500 Ekip Touch LSI
1SDA071085R1
1SDA071715R1
E2.2H 2500 Ekip Touch LSIG
1SDA071086R1
1SDA071716R1
E2.2H 2500 Ekip Hi-Touch LSI
1SDA071088R1
1SDA071718R1
E2.2H 2500 Ekip Hi-Touch LSIG
1SDA071089R1
1SDA071719R1
9/14 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 14
15/04/2013 18:00:45
1SDC200663F001
SACE Emax E4.2N-S • Orientable rear terminals (HR)
Size
E4.2N
Iu
3200
4000
E4.2S
3200
4000
Icu
Icw
(440 V) (1s)
Type
66
66
85
85
66
66
66
66
3 Poles
4 Poles
Code
Code
E4.2N 3200 Ekip Dip LI
1SDA071141R1
1SDA071771R1
E4.2N 3200 Ekip Dip LSI
1SDA071142R1
1SDA071772R1
E4.2N 3200 Ekip Dip LSIG
1SDA071143R1
1SDA071773R1
E4.2N 3200 Ekip Touch LI
1SDA071144R1
1SDA071774R1
E4.2N 3200 Ekip Touch LSI
1SDA071145R1
1SDA071775R1
E4.2N 3200 Ekip Touch LSIG
1SDA071146R1
1SDA071776R1
E4.2N 3200 Ekip Hi-Touch LSI
1SDA071148R1
1SDA071778R1
E4.2N 3200 Ekip Hi-Touch LSIG
1SDA071149R1
1SDA071779R1
E4.2N 4000 Ekip Dip LI
1SDA071191R1
1SDA071821R1
E4.2N 4000 Ekip Dip LSI
1SDA071192R1
1SDA071822R1
E4.2N 4000 Ekip Dip LSIG
1SDA071193R1
1SDA071823R1
E4.2N 4000 Ekip Touch LI
1SDA071194R1
1SDA071824R1
E4.2N 4000 Ekip Touch LSI
1SDA071195R1
1SDA071825R1
E4.2N 4000 Ekip Touch LSIG
1SDA071196R1
1SDA071826R1
E4.2N 4000 Ekip Hi-Touch LSI
1SDA071198R1
1SDA071828R1
E4.2N 4000 Ekip Hi-Touch LSIG
1SDA071199R1
1SDA071829R1
E4.2S 3200 Ekip Dip LI
1SDA071151R1
1SDA071781R1
E4.2S 3200 Ekip Dip LSI
1SDA071152R1
1SDA071782R1
E4.2S 3200 Ekip Dip LSIG
1SDA071153R1
1SDA071783R1
E4.2S 3200 Ekip Touch LI
1SDA071154R1
1SDA071784R1
E4.2S 3200 Ekip Touch LSI
1SDA071155R1
1SDA071785R1
E4.2S 3200 Ekip Touch LSIG
1SDA071156R1
1SDA071786R1
E4.2S 3200 Ekip Hi-Touch LSI
1SDA071158R1
1SDA071788R1
E4.2S 3200 Ekip Hi-Touch LSIG
1SDA071159R1
1SDA071789R1
E4.2S 4000 Ekip Dip LI
1SDA071201R1
1SDA071831R1
E4.2S 4000 Ekip Dip LSI
1SDA071202R1
1SDA071832R1
E4.2S 4000 Ekip Dip LSIG
1SDA071203R1
1SDA071833R1
E4.2S 4000 Ekip Touch LI
1SDA071204R1
1SDA071834R1
E4.2S 4000 Ekip Touch LSI
1SDA071205R1
1SDA071835R1
E4.2S 4000 Ekip Touch LSIG
1SDA071206R1
1SDA071836R1
E4.2S 4000 Ekip Hi-Touch LSI
1SDA071208R1
1SDA071838R1
E4.2S 4000 Ekip Hi-Touch LSIG
1SDA071209R1
1SDA071839R1
9
ABB Catalogue | 1SDC200023D0201 | 9/15
Emax2_cap09.indd 15
15/04/2013 18:00:46
Automatic circuit-breakers
Fixed version for power distribution
1SDC200663F001
SACE Emax E4.2H-V • Orientable rear terminals (HR)
Size
E4.2H
Iu
3200
4000
E4.2V
2000
Icu
Icw
(440 V) (1s)
Type
100
100
150
85
85
100
9
2500
3200
4000
150
150
150
100
100
100
3 Poles
4 Poles
Code
Code
E4.2H 3200 Ekip Dip LI
1SDA071161R1
1SDA071791R1
E4.2H 3200 Ekip Dip LSI
1SDA071162R1
1SDA071792R1
E4.2H 3200 Ekip Dip LSIG
1SDA071163R1
1SDA071793R1
E4.2H 3200 Ekip Touch LI
1SDA071164R1
1SDA071794R1
E4.2H 3200 Ekip Touch LSI
1SDA071165R1
1SDA071795R1
E4.2H 3200 Ekip Touch LSIG
1SDA071166R1
1SDA071796R1
E4.2H 3200 Ekip Hi-Touch LSI
1SDA071168R1
1SDA071798R1
E4.2H 3200 Ekip Hi-Touch LSIG
1SDA071169R1
1SDA071799R1
E4.2H 4000 Ekip Dip LI
1SDA071211R1
1SDA071841R1
E4.2H 4000 Ekip Dip LSI
1SDA071212R1
1SDA071842R1
E4.2H 4000 Ekip Dip LSIG
1SDA071213R1
1SDA071843R1
E4.2H 4000 Ekip Touch LI
1SDA071214R1
1SDA071844R1
E4.2H 4000 Ekip Touch LSI
1SDA071215R1
1SDA071845R1
E4.2H 4000 Ekip Touch LSIG
1SDA071216R1
1SDA071846R1
E4.2H 4000 Ekip Hi-Touch LSI
1SDA071218R1
1SDA071848R1
E4.2H 4000 Ekip Hi-Touch LSIG
1SDA071219R1
1SDA071849R1
E4.2V 2000 Ekip Dip LI
1SDA071101R1
1SDA071731R1
E4.2V 2000 Ekip Dip LSI
1SDA071102R1
1SDA071732R1
E4.2V 2000 Ekip Dip LSIG
1SDA071103R1
1SDA071733R1
E4.2V 2000 Ekip Touch LI
1SDA071104R1
1SDA071734R1
E4.2V 2000 Ekip Touch LSI
1SDA071105R1
1SDA071735R1
E4.2V 2000 Ekip Touch LSIG
1SDA071106R1
1SDA071736R1
E4.2V 2000 Ekip Hi-Touch LSI
1SDA071108R1
1SDA071738R1
E4.2V 2000 Ekip Hi-Touch LSIG
1SDA071109R1
1SDA071739R1
E4.2V 2500 Ekip Dip LI
1SDA071121R1
1SDA071751R1
E4.2V 2500 Ekip Dip LSI
1SDA071122R1
1SDA071752R1
E4.2V 2500 Ekip Dip LSIG
1SDA071123R1
1SDA071753R1
E4.2V 2500 Ekip Touch LI
1SDA071124R1
1SDA071754R1
E4.2V 2500 Ekip Touch LSI
1SDA071125R1
1SDA071755R1
E4.2V 2500 Ekip Touch LSIG
1SDA071126R1
1SDA071756R1
E4.2V 2500 Ekip Hi-Touch LSI
1SDA071128R1
1SDA071758R1
E4.2V 2500 Ekip Hi-Touch LSIG
1SDA071129R1
1SDA071759R1
E4.2V 3200 Ekip Dip LI
1SDA071171R1
1SDA071801R1
E4.2V 3200 Ekip Dip LSI
1SDA071172R1
1SDA071802R1
E4.2V 3200 Ekip Dip LSIG
1SDA071173R1
1SDA071803R1
E4.2V 3200 Ekip Touch LI
1SDA071174R1
1SDA071804R1
E4.2V 3200 Ekip Touch LSI
1SDA071175R1
1SDA071805R1
E4.2V 3200 Ekip Touch LSIG
1SDA071176R1
1SDA071806R1
E4.2V 3200 Ekip Hi-Touch LSI
1SDA071178R1
1SDA071808R1
E4.2V 3200 Ekip Hi-Touch LSIG
1SDA071179R1
1SDA071809R1
E4.2V 4000 Ekip Dip LI
1SDA071221R1
1SDA071851R1
E4.2V 4000 Ekip Dip LSI
1SDA071222R1
1SDA071852R1
E4.2V 4000 Ekip Dip LSIG
1SDA071223R1
1SDA071853R1
E4.2V 4000 Ekip Touch LI
1SDA071224R1
1SDA071854R1
E4.2V 4000 Ekip Touch LSI
1SDA071225R1
1SDA071855R1
E4.2V 4000 Ekip Touch LSIG
1SDA071226R1
1SDA071856R1
E4.2V 4000 Ekip Hi-Touch LSI
1SDA071228R1
1SDA071858R1
E4.2V 4000 Ekip Hi-Touch LSIG
1SDA071229R1
1SDA071859R1
9/16 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 16
15/04/2013 18:00:46
SACE Emax E6.2H-V • Orientable rear terminals (HR)
1SDC200664F001
Size
E6.2H
Iu
4000
5000
6300
E6.2V
4000
5000
6300
Icu
Icw
(440 V) (1s)
Type
100
100
100
150
150
150
100
100
100
100
100
100
3 Poles
4 Poles
Code
Code
E6.2H 4000 Ekip Dip LI
1SDA071231R1
1SDA071861R1
E6.2H 4000 Ekip Dip LSI
1SDA071232R1
1SDA071862R1
E6.2H 4000 Ekip Dip LSIG
1SDA071233R1
1SDA071863R1
E6.2H 4000 Ekip Touch LI
1SDA071234R1
1SDA071864R1
E6.2H 4000 Ekip Touch LSI
1SDA071235R1
1SDA071865R1
E6.2H 4000 Ekip Touch LSIG
1SDA071236R1
1SDA071866R1
E6.2H 4000 Ekip Hi-Touch LSI
1SDA071238R1
1SDA071868R1
E6.2H 4000 Ekip Hi-Touch LSIG
1SDA071239R1
1SDA071869R1
E6.2H 5000 Ekip Dip LI
1SDA071261R1
1SDA071891R1
E6.2H 5000 Ekip Dip LSI
1SDA071262R1
1SDA071892R1
E6.2H 5000 Ekip Dip LSIG
1SDA071263R1
1SDA071893R1
E6.2H 5000 Ekip Touch LI
1SDA071264R1
1SDA071894R1
E6.2H 5000 Ekip Touch LSI
1SDA071265R1
1SDA071895R1
E6.2H 5000 Ekip Touch LSIG
1SDA071266R1
1SDA071896R1
E6.2H 5000 Ekip Hi-Touch LSI
1SDA071268R1
1SDA071898R1
E6.2H 5000 Ekip Hi-Touch LSIG
1SDA071269R1
1SDA071899R1
E6.2H 6300 Ekip Dip LI
1SDA071291R1
1SDA071921R1
E6.2H 6300 Ekip Dip LSI
1SDA071292R1
1SDA071922R1
E6.2H 6300 Ekip Dip LSIG
1SDA071293R1
1SDA071923R1
E6.2H 6300 Ekip Touch LI
1SDA071294R1
1SDA071924R1
E6.2H 6300 Ekip Touch LSI
1SDA071295R1
1SDA071925R1
E6.2H 6300 Ekip Touch LSIG
1SDA071296R1
1SDA071926R1
E6.2H 6300 Ekip Hi-Touch LSI
1SDA071298R1
1SDA071928R1
E6.2H 6300 Ekip Hi-Touch LSIG
1SDA071299R1
1SDA071929R1
E6.2V 4000 Ekip Dip LI
1SDA071241R1
1SDA071871R1
E6.2V 4000 Ekip Dip LSI
1SDA071242R1
1SDA071872R1
E6.2V 4000 Ekip Dip LSIG
1SDA071243R1
1SDA071873R1
E6.2V 4000 Ekip Touch LI
1SDA071244R1
1SDA071874R1
E6.2V 4000 Ekip Touch LSI
1SDA071245R1
1SDA071875R1
E6.2V 4000 Ekip Touch LSIG
1SDA071246R1
1SDA071876R1
E6.2V 4000 Ekip Hi-Touch LSI
1SDA071248R1
1SDA071878R1
E6.2V 4000 Ekip Hi-Touch LSIG
1SDA071249R1
1SDA071879R1
E6.2V 5000 Ekip Dip LI
1SDA071271R1
1SDA071901R1
E6.2V 5000 Ekip Dip LSI
1SDA071272R1
1SDA071902R1
E6.2V 5000 Ekip Dip LSIG
1SDA071273R1
1SDA071903R1
E6.2V 5000 Ekip Touch LI
1SDA071274R1
1SDA071904R1
E6.2V 5000 Ekip Touch LSI
1SDA071275R1
1SDA071905R1
E6.2V 5000 Ekip Touch LSIG
1SDA071276R1
1SDA071906R1
E6.2V 5000 Ekip Hi-Touch LSI
1SDA071278R1
1SDA071908R1
E6.2V 5000 Ekip Hi-Touch LSIG
1SDA071279R1
1SDA071909R1
E6.2V 6300 Ekip Dip LI
1SDA071301R1
1SDA071931R1
E6.2V 6300 Ekip Dip LSI
1SDA071302R1
1SDA071932R1
E6.2V 6300 Ekip Dip LSIG
1SDA071303R1
1SDA071933R1
E6.2V 6300 Ekip Touch LI
1SDA071304R1
1SDA071934R1
E6.2V 6300 Ekip Touch LSI
1SDA071305R1
1SDA071935R1
E6.2V 6300 Ekip Touch LSIG
1SDA071306R1
1SDA071936R1
E6.2V 6300 Ekip Hi-Touch LSI
1SDA071308R1
1SDA071938R1
E6.2V 6300 Ekip Hi-Touch LSIG
1SDA071309R1
1SDA071939R1
9
ABB Catalogue | 1SDC200023D0201 | 9/17
Emax2_cap09.indd 17
15/04/2013 18:00:47
Automatic circuit-breakers
Fixed version for power distribution
SACE Emax E6.2X • Orientable rear terminals (HR)
1SDC200664F001
Size
E6.2X
Iu
4000
5000
6300
9
Icu
Icw
(440 V) (1s)
Type
200
200
200
120
120
120
3 Poles
4 Poles
Code
Code
E6.2X 4000 Ekip Dip LI
1SDA071251R1
1SDA071881R1
E6.2X 4000 Ekip Dip LSI
1SDA071252R1
1SDA071882R1
E6.2X 4000 Ekip Dip LSIG
1SDA071253R1
1SDA071883R1
E6.2X 4000 Ekip Touch LI
1SDA071254R1
1SDA071884R1
E6.2X 4000 Ekip Touch LSI
1SDA071255R1
1SDA071885R1
E6.2X 4000 Ekip Touch LSIG
1SDA071256R1
1SDA071886R1
E6.2X 4000 Ekip Hi-Touch LSI
1SDA071258R1
1SDA071888R1
E6.2X 4000 Ekip Hi-Touch LSIG
1SDA071259R1
1SDA071889R1
E6.2X 5000 Ekip Dip LI
1SDA071281R1
1SDA071911R1
E6.2X 5000 Ekip Dip LSI
1SDA071282R1
1SDA071912R1
E6.2X 5000 Ekip Dip LSIG
1SDA071283R1
1SDA071913R1
E6.2X 5000 Ekip Touch LI
1SDA071284R1
1SDA071914R1
E6.2X 5000 Ekip Touch LSI
1SDA071285R1
1SDA071915R1
E6.2X 5000 Ekip Touch LSIG
1SDA071286R1
1SDA071916R1
E6.2X 5000 Ekip Hi-Touch LSI
1SDA071288R1
1SDA071918R1
E6.2X 5000 Ekip Hi-Touch LSIG
1SDA071289R1
1SDA071919R1
E6.2X 6300 Ekip Dip LI
1SDA071311R1
1SDA071941R1
E6.2X 6300 Ekip Dip LSI
1SDA071312R1
1SDA071942R1
E6.2X 6300 Ekip Dip LSIG
1SDA071313R1
1SDA071943R1
E6.2X 6300 Ekip Touch LI
1SDA071314R1
1SDA071944R1
E6.2X 6300 Ekip Touch LSI
1SDA071315R1
1SDA071945R1
E6.2X 6300 Ekip Touch LSIG
1SDA071316R1
1SDA071946R1
E6.2X 6300 Ekip Hi-Touch LSI
1SDA071318R1
1SDA071948R1
E6.2X 6300 Ekip Hi-Touch LSIG
1SDA071319R1
1SDA071949R1
9/18 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 18
15/04/2013 18:00:48
SACE Emax E6.2H-V/f Full size • Orientable rear terminals (HR)
1SDC200664F001
Size
Iu
Icu (440V)
Icw (1s)
Type
4 Poles
Code
E6.2H/f
4000
5000
6300
E6.2V/f
4000
5000
6300
100
100
100
150
150
150
100
100
100
100
100
100
E6.2H/f 4000 Ekip Dip LI
1SDA071951R1
E6.2H/f 4000 Ekip Dip LSI
1SDA071952R1
E6.2H/f 4000 Ekip Dip LSIG
1SDA071953R1
E6.2H/f 4000 Ekip Touch LI
1SDA071954R1
E6.2H/f 4000 Ekip Touch LSI
1SDA071955R1
E6.2H/f 4000 Ekip Touch LSIG
1SDA071956R1
E6.2H/f 4000 Ekip Hi-Touch LSI
1SDA071958R1
E6.2H/f 4000 Ekip Hi-Touch LSIG
1SDA071959R1
E6.2H/f 5000 Ekip Dip LI
1SDA071981R1
E6.2H/f 5000 Ekip Dip LSI
1SDA071982R1
E6.2H/f 5000 Ekip Dip LSIG
1SDA071983R1
E6.2H/f 5000 Ekip Touch LI
1SDA071984R1
E6.2H/f 5000 Ekip Touch LSI
1SDA071985R1
E6.2H/f 5000 Ekip Touch LSIG
1SDA071986R1
E6.2H/f 5000 Ekip Hi-Touch LSI
1SDA071988R1
E6.2H/f 5000 Ekip Hi-Touch LSIG
1SDA071989R1
E6.2H/f 6300 Ekip Dip LI
1SDA072011R1
E6.2H/f 6300 Ekip Dip LSI
1SDA072012R1
E6.2H/f 6300 Ekip Dip LSIG
1SDA072013R1
E6.2H/f 6300 Ekip Touch LI
1SDA072014R1
E6.2H/f 6300 Ekip Touch LSI
1SDA072015R1
E6.2H/f 6300 Ekip Touch LSIG
1SDA072016R1
E6.2H/f 6300 Ekip Hi-Touch LSI
1SDA072018R1
E6.2H/f 6300 Ekip Hi-Touch LSIG
1SDA072019R1
E6.2V/f 4000 Ekip Dip LI
1SDA071961R1
E6.2V/f 4000 Ekip Dip LSI
1SDA071962R1
E6.2V/f 4000 Ekip Dip LSIG
1SDA071963R1
E6.2V/f 4000 Ekip Touch LI
1SDA071964R1
E6.2V/f 4000 Ekip Touch LSI
1SDA071965R1
E6.2V/f 4000 Ekip Touch LSIG
1SDA071966R1
E6.2V/f 4000 Ekip Hi-Touch LSI
1SDA071968R1
E6.2V/f 4000 Ekip Hi-Touch LSIG
1SDA071969R1
E6.2V/f 5000 Ekip Dip LI
1SDA071991R1
E6.2V/f 5000 Ekip Dip LSI
1SDA071992R1
E6.2V/f 5000 Ekip Dip LSIG
1SDA071993R1
E6.2V/f 5000 Ekip Touch LI
1SDA071994R1
E6.2V/f 5000 Ekip Touch LSI
1SDA071995R1
E6.2V/f 5000 Ekip Touch LSIG
1SDA071996R1
E6.2V/f 5000 Ekip Hi-Touch LSI
1SDA071998R1
E6.2V/f 5000 Ekip Hi-Touch LSIG
1SDA071999R1
E6.2V/f 6300 Ekip Dip LI
1SDA072021R1
E6.2V/f 6300 Ekip Dip LSI
1SDA072022R1
E6.2V/f 6300 Ekip Dip LSIG
1SDA072023R1
E6.2V/f 6300 Ekip Touch LI
1SDA072024R1
E6.2V/f 6300 Ekip Touch LSI
1SDA072025R1
E6.2V/f 6300 Ekip Touch LSIG
1SDA072026R1
E6.2V/f 6300 Ekip Hi-Touch LSI
1SDA072028R1
E6.2V/f 6300 Ekip Hi-Touch LSIG
1SDA072029R1
9
ABB Catalogue | 1SDC200023D0201 | 9/19
Emax2_cap09.indd 19
15/04/2013 18:00:48
Automatic circuit-breakers
Fixed version for power distribution
SACE Emax E6.2X/f Full size • Orientable rear terminals (HR)
1SDC200664F001
Size
Iu
Icu (440V)
Icw (1s)
Type
4 Poles
Code
E6.2X/f
4000
5000
6300
9
200
200
200
120
120
120
E6.2X/f 4000 Ekip Dip LI
1SDA071971R1
E6.2X/f 4000 Ekip Dip LSI
1SDA071972R1
E6.2X/f 4000 Ekip Dip LSIG
1SDA071973R1
E6.2X/f 4000 Ekip Touch LI
1SDA071974R1
E6.2X/f 4000 Ekip Touch LSI
1SDA071975R1
E6.2X/f 4000 Ekip Touch LSIG
1SDA071976R1
E6.2X/f 4000 Ekip Hi-Touch LSI
1SDA071978R1
E6.2X/f 4000 Ekip Hi-Touch LSIG
1SDA071979R1
E6.2X/f 5000 Ekip Dip LI
1SDA072001R1
E6.2X/f 5000 Ekip Dip LSI
1SDA072002R1
E6.2X/f 5000 Ekip Dip LSIG
1SDA072003R1
E6.2X/f 5000 Ekip Touch LI
1SDA072004R1
E6.2X/f 5000 Ekip Touch LSI
1SDA072005R1
E6.2X/f 5000 Ekip Touch LSIG
1SDA072006R1
E6.2X/f 5000 Ekip Hi-Touch LSI
1SDA072008R1
E6.2X/f 5000 Ekip Hi-Touch LSIG
1SDA072009R1
E6.2X/f 6300 Ekip Dip LI
1SDA072031R1
E6.2X/f 6300 Ekip Dip LSI
1SDA072032R1
E6.2X/f 6300 Ekip Dip LSIG
1SDA072033R1
E6.2X/f 6300 Ekip Touch LI
1SDA072034R1
E6.2X/f 6300 Ekip Touch LSI
1SDA072035R1
E6.2X/f 6300 Ekip Touch LSIG
1SDA072036R1
E6.2X/f 6300 Ekip Hi-Touch LSI
1SDA072038R1
E6.2X/f 6300 Ekip Hi-Touch LSIG
1SDA072039R1
9/20 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 20
15/04/2013 18:00:49
Automatic circuit-breakers
Withdrawable version for power distribution
1SDC200665F001
SACE Emax E1.2B • Mobile part of withdrawable circuit-breaker (MP)
Size
E1.2B
Iu
630
800
1000
1250
1600
Icu
Icw
(440 V) (1s)
Type
42
42
42
42
42
42
42
42
42
42
3 Poles
4 Poles
Code
Code
E1.2B 630 Ekip Dip LI
1SDA072051R1
1SDA072681R1
E1.2B 630 Ekip Dip LSI
1SDA072052R1
1SDA072682R1
E1.2B 630 Ekip Dip LSIG
1SDA072053R1
1SDA072683R1
E1.2B 630 Ekip Touch LI
1SDA072054R1
1SDA072684R1
E1.2B 630 Ekip Touch LSI
1SDA072055R1
1SDA072685R1
E1.2B 630 Ekip Touch LSIG
1SDA072056R1
1SDA072686R1
E1.2B 630 Ekip Hi-Touch LSI
1SDA072058R1
1SDA072688R1
E1.2B 630 Ekip Hi-Touch LSIG
1SDA072059R1
1SDA072689R1
E1.2B 800 Ekip Dip LI
1SDA072091R1
1SDA072721R1
E1.2B 800 Ekip Dip LSI
1SDA072092R1
1SDA072722R1
E1.2B 800 Ekip Dip LSIG
1SDA072093R1
1SDA072723R1
E1.2B 800 Ekip Touch LI
1SDA072094R1
1SDA072724R1
E1.2B 800 Ekip Touch LSI
1SDA072095R1
1SDA072725R1
E1.2B 800 Ekip Touch LSIG
1SDA072096R1
1SDA072726R1
E1.2B 800 Ekip Hi-Touch LSI
1SDA072098R1
1SDA072728R1
E1.2B 800 Ekip Hi-Touch LSIG
1SDA072099R1
1SDA072729R1
E1.2B 1000 Ekip Dip LI
1SDA072131R1
1SDA072761R1
E1.2B 1000 Ekip Dip LSI
1SDA072132R1
1SDA072762R1
E1.2B 1000 Ekip Dip LSIG
1SDA072133R1
1SDA072763R1
E1.2B 1000 Ekip Touch LI
1SDA072134R1
1SDA072764R1
E1.2B 1000 Ekip Touch LSI
1SDA072135R1
1SDA072765R1
E1.2B 1000 Ekip Touch LSIG
1SDA072136R1
1SDA072766R1
E1.2B 1000 Ekip Hi-Touch LSI
1SDA072138R1
1SDA072768R1
E1.2B 1000 Ekip Hi-Touch LSIG
1SDA072139R1
1SDA072769R1
E1.2B 1250 Ekip Dip LI
1SDA072171R1
1SDA072801R1
E1.2B 1250 Ekip Dip LSI
1SDA072172R1
1SDA072802R1
E1.2B 1250 Ekip Dip LSIG
1SDA072173R1
1SDA072803R1
E1.2B 1250 Ekip Touch LI
1SDA072174R1
1SDA072804R1
E1.2B 1250 Ekip Touch LSI
1SDA072175R1
1SDA072805R1
E1.2B 1250 Ekip Touch LSIG
1SDA072176R1
1SDA072806R1
E1.2B 1250 Ekip Hi-Touch LSI
1SDA072178R1
1SDA072808R1
E1.2B 1250 Ekip Hi-Touch LSIG
1SDA072179R1
1SDA072809R1
E1.2B 1600 Ekip Dip LI
1SDA072211R1
1SDA072841R1
E1.2B 1600 Ekip Dip LSI
1SDA072212R1
1SDA072842R1
E1.2B 1600 Ekip Dip LSIG
1SDA072213R1
1SDA072843R1
E1.2B 1600 Ekip Touch LI
1SDA072214R1
1SDA072844R1
E1.2B 1600 Ekip Touch LSI
1SDA072215R1
1SDA072845R1
E1.2B 1600 Ekip Touch LSIG
1SDA072216R1
1SDA072846R1
E1.2B 1600 Ekip Hi-Touch LSI
1SDA072218R1
1SDA072848R1
E1.2B 1600 Ekip Hi-Touch LSIG
1SDA072219R1
1SDA072849R1
9
ABB Catalogue | 1SDC200023D0201 | 9/21
Emax2_cap09.indd 21
15/04/2013 18:00:50
Automatic circuit-breakers
Withdrawable version for power distribution
1SDC200665F001
SACE Emax E1.2C • Mobile part of withdrawable circuit-breaker (MP)
Size
E1.2C
Iu
630
800
1000
Icu
Icw
(440 V) (1s)
Type
50
50
50
42
42
42
9
1250
1600
50
50
42
42
3 Poles
4 Poles
Code
Code
E1.2C 630 Ekip Dip LI
1SDA072061R1
1SDA072691R1
E1.2C 630 Ekip Dip LSI
1SDA072062R1
1SDA072692R1
E1.2C 630 Ekip Dip LSIG
1SDA072063R1
1SDA072693R1
E1.2C 630 Ekip Touch LI
1SDA072064R1
1SDA072694R1
E1.2C 630 Ekip Touch LSI
1SDA072065R1
1SDA072695R1
E1.2C 630 Ekip Touch LSIG
1SDA072066R1
1SDA072696R1
E1.2C 630 Ekip Hi-Touch LSI
1SDA072068R1
1SDA072698R1
E1.2C 630 Ekip Hi-Touch LSIG
1SDA072069R1
1SDA072699R1
E1.2C 800 Ekip Dip LI
1SDA072101R1
1SDA072731R1
E1.2C 800 Ekip Dip LSI
1SDA072102R1
1SDA072732R1
E1.2C 800 Ekip Dip LSIG
1SDA072103R1
1SDA072733R1
E1.2C 800 Ekip Touch LI
1SDA072104R1
1SDA072734R1
E1.2C 800 Ekip Touch LSI
1SDA072105R1
1SDA072735R1
E1.2C 800 Ekip Touch LSIG
1SDA072106R1
1SDA072736R1
E1.2C 800 Ekip Hi-Touch LSI
1SDA072108R1
1SDA072738R1
E1.2C 800 Ekip Hi-Touch LSIG
1SDA072109R1
1SDA072739R1
E1.2C 1000 Ekip Dip LI
1SDA072141R1
1SDA072771R1
E1.2C 1000 Ekip Dip LSI
1SDA072142R1
1SDA072772R1
E1.2C 1000 Ekip Dip LSIG
1SDA072143R1
1SDA072773R1
E1.2C 1000 Ekip Touch LI
1SDA072144R1
1SDA072774R1
E1.2C 1000 Ekip Touch LSI
1SDA072145R1
1SDA072775R1
E1.2C 1000 Ekip Touch LSIG
1SDA072146R1
1SDA072776R1
E1.2C 1000 Ekip Hi-Touch LSI
1SDA072148R1
1SDA072778R1
E1.2C 1000 Ekip Hi-Touch LSIG
1SDA072149R1
1SDA072779R1
E1.2C 1250 Ekip Dip LI
1SDA072181R1
1SDA072811R1
E1.2C 1250 Ekip Dip LSI
1SDA072182R1
1SDA072812R1
E1.2C 1250 Ekip Dip LSIG
1SDA072183R1
1SDA072813R1
E1.2C 1250 Ekip Touch LI
1SDA072184R1
1SDA072814R1
E1.2C 1250 Ekip Touch LSI
1SDA072185R1
1SDA072815R1
E1.2C 1250 Ekip Touch LSIG
1SDA072186R1
1SDA072816R1
E1.2C 1250 Ekip Hi-Touch LSI
1SDA072188R1
1SDA072818R1
E1.2C 1250 Ekip Hi-Touch LSIG
1SDA072189R1
1SDA072819R1
E1.2C 1600 Ekip Dip LI
1SDA072221R1
1SDA072851R1
E1.2C 1600 Ekip Dip LSI
1SDA072222R1
1SDA072852R1
E1.2C 1600 Ekip Dip LSIG
1SDA072223R1
1SDA072853R1
E1.2C 1600 Ekip Touch LI
1SDA072224R1
1SDA072854R1
E1.2C 1600 Ekip Touch LSI
1SDA072225R1
1SDA072855R1
E1.2C 1600 Ekip Touch LSIG
1SDA072226R1
1SDA072856R1
E1.2C 1600 Ekip Hi-Touch LSI
1SDA072228R1
1SDA072858R1
E1.2C 1600 Ekip Hi-Touch LSIG
1SDA072229R1
1SDA072859R1
9/22 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 22
15/04/2013 18:00:51
1SDC200665F001
SACE Emax E1.2N • Mobile part of withdrawable circuit-breaker (MP)
Size
E1.2N
Iu
250
630
800
1000
1250
1600
Icu
Icw
(440 V) (1s)
Type
66
66
66
66
66
66
50
50
50
50
50
50
3 Poles
4 Poles
Code
Code
E1.2N 250 Ekip Dip LI
1SDA072041R1
1SDA072671R1
E1.2N 250 Ekip Dip LSI
1SDA072042R1
1SDA072672R1
E1.2N 250 Ekip Dip LSIG
1SDA072043R1
1SDA072673R1
E1.2N 250 Ekip Touch LI
1SDA072044R1
1SDA072674R1
E1.2N 250 Ekip Touch LSI
1SDA072045R1
1SDA072675R1
E1.2N 250 Ekip Touch LSIG
1SDA072046R1
1SDA072676R1
E1.2N 250 Ekip Hi-Touch LSI
1SDA072048R1
1SDA072678R1
E1.2N 250 Ekip Hi-Touch LSIG
1SDA072049R1
1SDA072679R1
E1.2N 630 Ekip Dip LI
1SDA072071R1
1SDA072701R1
E1.2N 630 Ekip Dip LSI
1SDA072072R1
1SDA072702R1
E1.2N 630 Ekip Dip LSIG
1SDA072073R1
1SDA072703R1
E1.2N 630 Ekip Touch LI
1SDA072074R1
1SDA072704R1
E1.2N 630 Ekip Touch LSI
1SDA072075R1
1SDA072705R1
E1.2N 630 Ekip Touch LSIG
1SDA072076R1
1SDA072706R1
E1.2N 630 Ekip Hi-Touch LSI
1SDA072078R1
1SDA072708R1
E1.2N 630 Ekip Hi-Touch LSIG
1SDA072079R1
1SDA072709R1
E1.2N 800 Ekip Dip LI
1SDA072111R1
1SDA072741R1
E1.2N 800 Ekip Dip LSI
1SDA072112R1
1SDA072742R1
E1.2N 800 Ekip Dip LSIG
1SDA072113R1
1SDA072743R1
E1.2N 800 Ekip Touch LI
1SDA072114R1
1SDA072744R1
E1.2N 800 Ekip Touch LSI
1SDA072115R1
1SDA072745R1
E1.2N 800 Ekip Touch LSIG
1SDA072116R1
1SDA072746R1
E1.2N 800 Ekip Hi-Touch LSI
1SDA072118R1
1SDA072748R1
E1.2N 800 Ekip Hi-Touch LSIG
1SDA072119R1
1SDA072749R1
E1.2N 1000 Ekip Dip LI
1SDA072151R1
1SDA072781R1
E1.2N 1000 Ekip Dip LSI
1SDA072152R1
1SDA072782R1
E1.2N 1000 Ekip Dip LSIG
1SDA072153R1
1SDA072783R1
E1.2N 1000 Ekip Touch LI
1SDA072154R1
1SDA072784R1
E1.2N 1000 Ekip Touch LSI
1SDA072155R1
1SDA072785R1
E1.2N 1000 Ekip Touch LSIG
1SDA072156R1
1SDA072786R1
E1.2N 1000 Ekip Hi-Touch LSI
1SDA072158R1
1SDA072788R1
E1.2N 1000 Ekip Hi-Touch LSIG
1SDA072159R1
1SDA072789R1
E1.2N 1250 Ekip Dip LI
1SDA072191R1
1SDA072821R1
E1.2N 1250 Ekip Dip LSI
1SDA072192R1
1SDA072822R1
E1.2N 1250 Ekip Dip LSIG
1SDA072193R1
1SDA072823R1
E1.2N 1250 Ekip Touch LI
1SDA072194R1
1SDA072824R1
E1.2N 1250 Ekip Touch LSI
1SDA072195R1
1SDA072825R1
E1.2N 1250 Ekip Touch LSIG
1SDA072196R1
1SDA072826R1
E1.2N 1250 Ekip Hi-Touch LSI
1SDA072198R1
1SDA072828R1
E1.2N 1250 Ekip Hi-Touch LSIG
1SDA072199R1
1SDA072829R1
E1.2N 1600 Ekip Dip LI
1SDA072231R1
1SDA072861R1
E1.2N 1600 Ekip Dip LSI
1SDA072232R1
1SDA072862R1
E1.2N 1600 Ekip Dip LSIG
1SDA072233R1
1SDA072863R1
E1.2N 1600 Ekip Touch LI
1SDA072234R1
1SDA072864R1
E1.2N 1600 Ekip Touch LSI
1SDA072235R1
1SDA072865R1
E1.2N 1600 Ekip Touch LSIG
1SDA072236R1
1SDA072866R1
E1.2N 1600 Ekip Hi-Touch LSI
1SDA072238R1
1SDA072868R1
E1.2N 1600 Ekip Hi-Touch LSIG
1SDA072239R1
1SDA072869R1
9
ABB Catalogue | 1SDC200023D0201 | 9/23
Emax2_cap09.indd 23
15/04/2013 18:00:52
Automatic circuit-breakers
Withdrawable version for power distribution
1SDC200665F001
SACE Emax E1.2L-B • Mobile part of withdrawable circuit-breaker (MP)
Size
E1.2L
Iu
630
800
1000
Icu
Icw
(440 V) (1s)
Type
130
130
130
15
15
15
9
1250
E2.2B
1600
2000
130
42
42
15
42
42
3 Poles
4 Poles
Code
Code
E1.2L 630 Ekip Dip LI
1SDA072081R1
1SDA072711R1
E1.2L 630 Ekip Dip LSI
1SDA072082R1
1SDA072712R1
E1.2L 630 Ekip Dip LSIG
1SDA072083R1
1SDA072713R1
E1.2L 630 Ekip Touch LI
1SDA072084R1
1SDA072714R1
E1.2L 630 Ekip Touch LSI
1SDA072085R1
1SDA072715R1
E1.2L 630 Ekip Touch LSIG
1SDA072086R1
1SDA072716R1
E1.2L 630 Ekip Hi-Touch LSI
1SDA072088R1
1SDA072718R1
E1.2L 630 Ekip Hi-Touch LSIG
1SDA072089R1
1SDA072719R1
E1.2L 800 Ekip Dip LI
1SDA072121R1
1SDA072751R1
E1.2L 800 Ekip Dip LSI
1SDA072122R1
1SDA072752R1
E1.2L 800 Ekip Dip LSIG
1SDA072123R1
1SDA072753R1
E1.2L 800 Ekip Touch LI
1SDA072124R1
1SDA072754R1
E1.2L 800 Ekip Touch LSI
1SDA072125R1
1SDA072755R1
E1.2L 800 Ekip Touch LSIG
1SDA072126R1
1SDA072756R1
E1.2L 800 Ekip Hi-Touch LSI
1SDA072128R1
1SDA072758R1
E1.2L 800 Ekip Hi-Touch LSIG
1SDA072129R1
1SDA072759R1
E1.2L 1000 Ekip Dip LI
1SDA072161R1
1SDA072791R1
E1.2L 1000 Ekip Dip LSI
1SDA072162R1
1SDA072792R1
E1.2L 1000 Ekip Dip LSIG
1SDA072163R1
1SDA072793R1
E1.2L 1000 Ekip Touch LI
1SDA072164R1
1SDA072794R1
E1.2L 1000 Ekip Touch LSI
1SDA072165R1
1SDA072795R1
E1.2L 1000 Ekip Touch LSIG
1SDA072166R1
1SDA072796R1
E1.2L 1000 Ekip Hi-Touch LSI
1SDA072168R1
1SDA072798R1
E1.2L 1000 Ekip Hi-Touch LSIG
1SDA072169R1
1SDA072799R1
E1.2L 1250 Ekip Dip LI
1SDA072201R1
1SDA072831R1
E1.2L 1250 Ekip Dip LSI
1SDA072202R1
1SDA072832R1
E1.2L 1250 Ekip Dip LSIG
1SDA072203R1
1SDA072833R1
E1.2L 1250 Ekip Touch LI
1SDA072204R1
1SDA072834R1
E1.2L 1250 Ekip Touch LSI
1SDA072205R1
1SDA072835R1
E1.2L 1250 Ekip Touch LSIG
1SDA072206R1
1SDA072836R1
E1.2L 1250 Ekip Hi-Touch LSI
1SDA072208R1
1SDA072838R1
E1.2L 1250 Ekip Hi-Touch LSIG
1SDA072209R1
1SDA072839R1
E2.2B 1600 Ekip Dip LI
1SDA072331R1
1SDA072961R1
E2.2B 1600 Ekip Dip LSI
1SDA072332R1
1SDA072962R1
E2.2B 1600 Ekip Dip LSIG
1SDA072333R1
1SDA072963R1
E2.2B 1600 Ekip Touch LI
1SDA072334R1
1SDA072964R1
E2.2B 1600 Ekip Touch LSI
1SDA072335R1
1SDA072965R1
E2.2B 1600 Ekip Touch LSIG
1SDA072336R1
1SDA072966R1
E2.2B 1600 Ekip Hi-Touch LSI
1SDA072338R1
1SDA072968R1
E2.2B 1600 Ekip Hi-Touch LSIG
1SDA072339R1
1SDA072969R1
E2.2B 2000 Ekip Dip LI
1SDA072371R1
1SDA073001R1
E2.2B 2000 Ekip Dip LSI
1SDA072372R1
1SDA073002R1
E2.2B 2000 Ekip Dip LSIG
1SDA072373R1
1SDA073003R1
E2.2B 2000 Ekip Touch LI
1SDA072374R1
1SDA073004R1
E2.2B 2000 Ekip Touch LSI
1SDA072375R1
1SDA073005R1
E2.2B 2000 Ekip Touch LSIG
1SDA072376R1
1SDA073006R1
E2.2B 2000 Ekip Hi-Touch LSI
1SDA072378R1
1SDA073008R1
E2.2B 2000 Ekip Hi-Touch LSIG
1SDA072379R1
1SDA073009R1
9/24 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 24
15/04/2013 18:00:53
SACE Emax E2.2N • Mobile part of withdrawable circuit-breaker (MP)
1SDC200666F001
Size
E2.2N
Iu
800
1000
1250
1600
2000
2500
Icu
Icw
(440 V) (1s)
Type
66
66
66
66
66
66
66
66
66
66
66
66
3 Poles
4 Poles
Code
Code
E2.2N 800 Ekip Dip LI
1SDA072241R1
1SDA072871R1
E2.2N 800 Ekip Dip LSI
1SDA072242R1
1SDA072872R1
E2.2N 800 Ekip Dip LSIG
1SDA072243R1
1SDA072873R1
E2.2N 800 Ekip Touch LI
1SDA072244R1
1SDA072874R1
E2.2N 800 Ekip Touch LSI
1SDA072245R1
1SDA072875R1
E2.2N 800 Ekip Touch LSIG
1SDA072246R1
1SDA072876R1
E2.2N 800 Ekip Hi-Touch LSI
1SDA072248R1
1SDA072878R1
E2.2N 800 Ekip Hi-Touch LSIG
1SDA072249R1
1SDA072879R1
E2.2N 1000 Ekip Dip LI
1SDA072271R1
1SDA072901R1
E2.2N 1000 Ekip Dip LSI
1SDA072272R1
1SDA072902R1
E2.2N 1000 Ekip Dip LSIG
1SDA072273R1
1SDA072903R1
E2.2N 1000 Ekip Touch LI
1SDA072274R1
1SDA072904R1
E2.2N 1000 Ekip Touch LSI
1SDA072275R1
1SDA072905R1
E2.2N 1000 Ekip Touch LSIG
1SDA072276R1
1SDA072906R1
E2.2N 1000 Ekip Hi-Touch LSI
1SDA072278R1
1SDA072908R1
E2.2N 1000 Ekip Hi-Touch LSIG
1SDA072279R1
1SDA072909R1
E2.2N 1250 Ekip Dip LI
1SDA072301R1
1SDA072931R1
E2.2N 1250 Ekip Dip LSI
1SDA072302R1
1SDA072932R1
E2.2N 1250 Ekip Dip LSIG
1SDA072303R1
1SDA072933R1
E2.2N 1250 Ekip Touch LI
1SDA072304R1
1SDA072934R1
E2.2N 1250 Ekip Touch LSI
1SDA072305R1
1SDA072935R1
E2.2N 1250 Ekip Touch LSIG
1SDA072306R1
1SDA072936R1
E2.2N 1250 Ekip Hi-Touch LSI
1SDA072308R1
1SDA072938R1
E2.2N 1250 Ekip Hi-Touch LSIG
1SDA072309R1
1SDA072939R1
E2.2N 1600 Ekip Dip LI
1SDA072341R1
1SDA072971R1
E2.2N 1600 Ekip Dip LSI
1SDA072342R1
1SDA072972R1
E2.2N 1600 Ekip Dip LSIG
1SDA072343R1
1SDA072973R1
E2.2N 1600 Ekip Touch LI
1SDA072344R1
1SDA072974R1
E2.2N 1600 Ekip Touch LSI
1SDA072345R1
1SDA072975R1
E2.2N 1600 Ekip Touch LSIG
1SDA072346R1
1SDA072976R1
E2.2N 1600 Ekip Hi-Touch LSI
1SDA072348R1
1SDA072978R1
E2.2N 1600 Ekip Hi-Touch LSIG
1SDA072349R1
1SDA072979R1
E2.2N 2000 Ekip Dip LI
1SDA072381R1
1SDA073011R1
E2.2N 2000 Ekip Dip LSI
1SDA072382R1
1SDA073012R1
E2.2N 2000 Ekip Dip LSIG
1SDA072383R1
1SDA073013R1
E2.2N 2000 Ekip Touch LI
1SDA072384R1
1SDA073014R1
E2.2N 2000 Ekip Touch LSI
1SDA072385R1
1SDA073015R1
E2.2N 2000 Ekip Touch LSIG
1SDA072386R1
1SDA073016R1
E2.2N 2000 Ekip Hi-Touch LSI
1SDA072388R1
1SDA073018R1
E2.2N 2000 Ekip Hi-Touch LSIG
1SDA072389R1
1SDA073019R1
E2.2N 2500 Ekip Dip LI
1SDA072411R1
1SDA073041R1
E2.2N 2500 Ekip Dip LSI
1SDA072412R1
1SDA073042R1
E2.2N 2500 Ekip Dip LSIG
1SDA072413R1
1SDA073043R1
E2.2N 2500 Ekip Touch LI
1SDA072414R1
1SDA073044R1
E2.2N 2500 Ekip Touch LSI
1SDA072415R1
1SDA073045R1
E2.2N 2500 Ekip Touch LSIG
1SDA072416R1
1SDA073046R1
E2.2N 2500 Ekip Hi-Touch LSI
1SDA072418R1
1SDA073048R1
E2.2N 2500 Ekip Hi-Touch LSIG
1SDA072419R1
1SDA073049R1
9
ABB Catalogue | 1SDC200023D0201 | 9/25
Emax2_cap09.indd 25
15/04/2013 18:00:54
Automatic circuit-breakers
Withdrawable version for power distribution
SACE Emax E2.2S • Mobile part of withdrawable circuit-breaker (MP)
1SDC200666F001
Size
E2.2S
Iu
250
800
1000
Icu
Icw
(440 V) (1s)
Type
85
85
85
66
66
66
9
1250
85
66
3 Poles
4 Poles
Code
Code
E2.2S 250 Ekip Dip LI
1SDA073648R1
1SDA073658R1
E2.2S 250 Ekip Dip LSI
1SDA073649R1
1SDA073659R1
E2.2S 250 Ekip Dip LSIG
1SDA073650R1
1SDA073660R1
E2.2S 250 Ekip Touch LI
1SDA073651R1
1SDA073661R1
E2.2S 250 Ekip Touch LSI
1SDA073652R1
1SDA073662R1
E2.2S 250 Ekip Touch LSIG
1SDA073653R1
1SDA073663R1
E2.2S 250 Ekip Hi-Touch LSI
1SDA073655R1
1SDA073665R1
E2.2S 250 Ekip Hi-Touch LSIG
1SDA073656R1
1SDA073666R1
E2.2S 800 Ekip Dip LI
1SDA072251R1
1SDA072881R1
E2.2S 800 Ekip Dip LSI
1SDA072252R1
1SDA072882R1
E2.2S 800 Ekip Dip LSIG
1SDA072253R1
1SDA072883R1
E2.2S 800 Ekip Touch LI
1SDA072254R1
1SDA072884R1
E2.2S 800 Ekip Touch LSI
1SDA072255R1
1SDA072885R1
E2.2S 800 Ekip Touch LSIG
1SDA072256R1
1SDA072886R1
E2.2S 800 Ekip Hi-Touch LSI
1SDA072258R1
1SDA072888R1
E2.2S 800 Ekip Hi-Touch LSIG
1SDA072259R1
1SDA072889R1
E2.2S 1000 Ekip Dip LI
1SDA072281R1
1SDA072911R1
E2.2S 1000 Ekip Dip LSI
1SDA072282R1
1SDA072912R1
E2.2S 1000 Ekip Dip LSIG
1SDA072283R1
1SDA072913R1
E2.2S 1000 Ekip Touch LI
1SDA072284R1
1SDA072914R1
E2.2S 1000 Ekip Touch LSI
1SDA072285R1
1SDA072915R1
E2.2S 1000 Ekip Touch LSIG
1SDA072286R1
1SDA072916R1
E2.2S 1000 Ekip Hi-Touch LSI
1SDA072288R1
1SDA072918R1
E2.2S 1000 Ekip Hi-Touch LSIG
1SDA072289R1
1SDA072919R1
E2.2S 1250 Ekip Dip LI
1SDA072311R1
1SDA072941R1
E2.2S 1250 Ekip Dip LSI
1SDA072312R1
1SDA072942R1
E2.2S 1250 Ekip Dip LSIG
1SDA072313R1
1SDA072943R1
E2.2S 1250 Ekip Touch LI
1SDA072314R1
1SDA072944R1
E2.2S 1250 Ekip Touch LSI
1SDA072315R1
1SDA072945R1
E2.2S 1250 Ekip Touch LSIG
1SDA072316R1
1SDA072946R1
E2.2S 1250 Ekip Hi-Touch LSI
1SDA072318R1
1SDA072948R1
E2.2S 1250 Ekip Hi-Touch LSIG
1SDA072319R1
1SDA072949R1
9/26 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 26
15/04/2013 18:00:56
SACE Emax E2.2S • Mobile part of withdrawable circuit-breaker (MP)
1SDC200666F001
Size
E2.2S
Iu
1600
2000
2500
Icu
Icw
(440 V) (1s)
Type
85
85
85
66
66
66
3 Poles
4 Poles
Code
Code
E2.2S 1600 Ekip Dip LI
1SDA072351R1
1SDA072981R1
E2.2S 1600 Ekip Dip LSI
1SDA072352R1
1SDA072982R1
E2.2S 1600 Ekip Dip LSIG
1SDA072353R1
1SDA072983R1
E2.2S 1600 Ekip Touch LI
1SDA072354R1
1SDA072984R1
E2.2S 1600 Ekip Touch LSI
1SDA072355R1
1SDA072985R1
E2.2S 1600 Ekip Touch LSIG
1SDA072356R1
1SDA072986R1
E2.2S 1600 Ekip Hi-Touch LSI
1SDA072358R1
1SDA072988R1
E2.2S 1600 Ekip Hi-Touch LSIG
1SDA072359R1
1SDA072989R1
E2.2S 2000 Ekip Dip LI
1SDA072391R1
1SDA073021R1
E2.2S 2000 Ekip Dip LSI
1SDA072392R1
1SDA073022R1
E2.2S 2000 Ekip Dip LSIG
1SDA072393R1
1SDA073023R1
E2.2S 2000 Ekip Touch LI
1SDA072394R1
1SDA073024R1
E2.2S 2000 Ekip Touch LSI
1SDA072395R1
1SDA073025R1
E2.2S 2000 Ekip Touch LSIG
1SDA072396R1
1SDA073026R1
E2.2S 2000 Ekip Hi-Touch LSI
1SDA072398R1
1SDA073028R1
E2.2S 2000 Ekip Hi-Touch LSIG
1SDA072399R1
1SDA073029R1
E2.2S 2500 Ekip Dip LI
1SDA072421R1
1SDA073051R1
E2.2S 2500 Ekip Dip LSI
1SDA072422R1
1SDA073052R1
E2.2S 2500 Ekip Dip LSIG
1SDA072423R1
1SDA073053R1
E2.2S 2500 Ekip Touch LI
1SDA072424R1
1SDA073054R1
E2.2S 2500 Ekip Touch LSI
1SDA072425R1
1SDA073055R1
E2.2S 2500 Ekip Touch LSIG
1SDA072426R1
1SDA073056R1
E2.2S 2500 Ekip Hi-Touch LSI
1SDA072428R1
1SDA073058R1
E2.2S 2500 Ekip Hi-Touch LSIG
1SDA072429R1
1SDA073059R1
9
ABB Catalogue | 1SDC200023D0201 | 9/27
Emax2_cap09.indd 27
15/04/2013 18:00:57
Automatic circuit-breakers
Withdrawable version for power distribution
SACE Emax E2.2H • Mobile part of withdrawable circuit-breaker (MP)
1SDC200666F001
Size
E2.2H
Iu
800
1000
1250
Icu
Icw
(440 V) (1s)
Type
100
100
100
85
85
85
9
1600
2000
2500
100
100
100
85
85
85
3 Poles
4 Poles
Code
Code
E2.2H 800 Ekip Dip LI
1SDA072261R1
1SDA072891R1
E2.2H 800 Ekip Dip LSI
1SDA072262R1
1SDA072892R1
E2.2H 800 Ekip Dip LSIG
1SDA072263R1
1SDA072893R1
E2.2H 800 Ekip Touch LI
1SDA072264R1
1SDA072894R1
E2.2H 800 Ekip Touch LSI
1SDA072265R1
1SDA072895R1
E2.2H 800 Ekip Touch LSIG
1SDA072266R1
1SDA072896R1
E2.2H 800 Ekip Hi-Touch LSI
1SDA072268R1
1SDA072898R1
E2.2H 800 Ekip Hi-Touch LSIG
1SDA072269R1
1SDA072899R1
E2.2H 1000 Ekip Dip LI
1SDA072291R1
1SDA072921R1
E2.2H 1000 Ekip Dip LSI
1SDA072292R1
1SDA072922R1
E2.2H 1000 Ekip Dip LSIG
1SDA072293R1
1SDA072923R1
E2.2H 1000 Ekip Touch LI
1SDA072294R1
1SDA072924R1
E2.2H 1000 Ekip Touch LSI
1SDA072295R1
1SDA072925R1
E2.2H 1000 Ekip Touch LSIG
1SDA072296R1
1SDA072926R1
E2.2H 1000 Ekip Hi-Touch LSI
1SDA072298R1
1SDA072928R1
E2.2H 1000 Ekip Hi-Touch LSIG
1SDA072299R1
1SDA072929R1
E2.2H 1250 Ekip Dip LI
1SDA072321R1
1SDA072951R1
E2.2H 1250 Ekip Dip LSI
1SDA072322R1
1SDA072952R1
E2.2H 1250 Ekip Dip LSIG
1SDA072323R1
1SDA072953R1
E2.2H 1250 Ekip Touch LI
1SDA072324R1
1SDA072954R1
E2.2H 1250 Ekip Touch LSI
1SDA072325R1
1SDA072955R1
E2.2H 1250 Ekip Touch LSIG
1SDA072326R1
1SDA072956R1
E2.2H 1250 Ekip Hi-Touch LSI
1SDA072328R1
1SDA072958R1
E2.2H 1250 Ekip Hi-Touch LSIG
1SDA072329R1
1SDA072959R1
E2.2H 1600 Ekip Dip LI
1SDA072361R1
1SDA072991R1
E2.2H 1600 Ekip Dip LSI
1SDA072362R1
1SDA072992R1
E2.2H 1600 Ekip Dip LSIG
1SDA072363R1
1SDA072993R1
E2.2H 1600 Ekip Touch LI
1SDA072364R1
1SDA072994R1
E2.2H 1600 Ekip Touch LSI
1SDA072365R1
1SDA072995R1
E2.2H 1600 Ekip Touch LSIG
1SDA072366R1
1SDA072996R1
E2.2H 1600 Ekip Hi-Touch LSI
1SDA072368R1
1SDA072998R1
E2.2H 1600 Ekip Hi-Touch LSIG
1SDA072369R1
1SDA072999R1
E2.2H 2000 Ekip Dip LI
1SDA072401R1
1SDA073031R1
E2.2H 2000 Ekip Dip LSI
1SDA072402R1
1SDA073032R1
E2.2H 2000 Ekip Dip LSIG
1SDA072403R1
1SDA073033R1
E2.2H 2000 Ekip Touch LI
1SDA072404R1
1SDA073034R1
E2.2H 2000 Ekip Touch LSI
1SDA072405R1
1SDA073035R1
E2.2H 2000 Ekip Touch LSIG
1SDA072406R1
1SDA073036R1
E2.2H 2000 Ekip Hi-Touch LSI
1SDA072408R1
1SDA073038R1
E2.2H 2000 Ekip Hi-Touch LSIG
1SDA072409R1
1SDA073039R1
E2.2H 2500 Ekip Dip LI
1SDA072431R1
1SDA073061R1
E2.2H 2500 Ekip Dip LSI
1SDA072432R1
1SDA073062R1
E2.2H 2500 Ekip Dip LSIG
1SDA072433R1
1SDA073063R1
E2.2H 2500 Ekip Touch LI
1SDA072434R1
1SDA073064R1
E2.2H 2500 Ekip Touch LSI
1SDA072435R1
1SDA073065R1
E2.2H 2500 Ekip Touch LSIG
1SDA072436R1
1SDA073066R1
E2.2H 2500 Ekip Hi-Touch LSI
1SDA072438R1
1SDA073068R1
E2.2H 2500 Ekip Hi-Touch LSIG
1SDA072439R1
1SDA073069R1
9/28 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 28
15/04/2013 18:00:59
SACE Emax E4.2N-S-H • Mobile part of withdrawable circuit-breaker (MP)
1SDC200667F001
Size
E4.2N
Iu
3200
4000
E4.2S
3200
4000
E4.2H
3200
4000
Icu
Icw
(440 V) (1s)
Type
66
66
85
85
100
100
66
66
66
66
85
85
3 Poles
4 Poles
Code
Code
E4.2N 3200 Ekip Dip LI
1SDA072491R1
1SDA073121R1
E4.2N 3200 Ekip Dip LSI
1SDA072492R1
1SDA073122R1
E4.2N 3200 Ekip Dip LSIG
1SDA072493R1
1SDA073123R1
E4.2N 3200 Ekip Touch LI
1SDA072494R1
1SDA073124R1
E4.2N 3200 Ekip Touch LSI
1SDA072495R1
1SDA073125R1
E4.2N 3200 Ekip Touch LSIG
1SDA072496R1
1SDA073126R1
E4.2N 3200 Ekip Hi-Touch LSI
1SDA072498R1
1SDA073128R1
E4.2N 3200 Ekip Hi-Touch LSIG
1SDA072499R1
1SDA073129R1
E4.2N 4000 Ekip Dip LI
1SDA072541R1
1SDA073171R1
E4.2N 4000 Ekip Dip LSI
1SDA072542R1
1SDA073172R1
E4.2N 4000 Ekip Dip LSIG
1SDA072543R1
1SDA073173R1
E4.2N 4000 Ekip Touch LI
1SDA072544R1
1SDA073174R1
E4.2N 4000 Ekip Touch LSI
1SDA072545R1
1SDA073175R1
E4.2N 4000 Ekip Touch LSIG
1SDA072546R1
1SDA073176R1
E4.2N 4000 Ekip Hi-Touch LSI
1SDA072548R1
1SDA073178R1
E4.2N 4000 Ekip Hi-Touch LSIG
1SDA072549R1
1SDA073179R1
E4.2S 3200 Ekip Dip LI
1SDA072501R1
1SDA073131R1
E4.2S 3200 Ekip Dip LSI
1SDA072502R1
1SDA073132R1
E4.2S 3200 Ekip Dip LSIG
1SDA072503R1
1SDA073133R1
E4.2S 3200 Ekip Touch LI
1SDA072504R1
1SDA073134R1
E4.2S 3200 Ekip Touch LSI
1SDA072505R1
1SDA073135R1
E4.2S 3200 Ekip Touch LSIG
1SDA072506R1
1SDA073136R1
E4.2S 3200 Ekip Hi-Touch LSI
1SDA072508R1
1SDA073138R1
E4.2S 3200 Ekip Hi-Touch LSIG
1SDA072509R1
1SDA073139R1
E4.2S 4000 Ekip Dip LI
1SDA072551R1
1SDA073181R1
E4.2S 4000 Ekip Dip LSI
1SDA072552R1
1SDA073182R1
E4.2S 4000 Ekip Dip LSIG
1SDA072553R1
1SDA073183R1
E4.2S 4000 Ekip Touch LI
1SDA072554R1
1SDA073184R1
E4.2S 4000 Ekip Touch LSI
1SDA072555R1
1SDA073185R1
E4.2S 4000 Ekip Touch LSIG
1SDA072556R1
1SDA073186R1
E4.2S 4000 Ekip Hi-Touch LSI
1SDA072558R1
1SDA073188R1
E4.2S 4000 Ekip Hi-Touch LSIG
1SDA072559R1
1SDA073189R1
E4.2H 3200 Ekip Dip LI
1SDA072511R1
1SDA073141R1
E4.2H 3200 Ekip Dip LSI
1SDA072512R1
1SDA073142R1
E4.2H 3200 Ekip Dip LSIG
1SDA072513R1
1SDA073143R1
E4.2H 3200 Ekip Touch LI
1SDA072514R1
1SDA073144R1
E4.2H 3200 Ekip Touch LSI
1SDA072515R1
1SDA073145R1
E4.2H 3200 Ekip Touch LSIG
1SDA072516R1
1SDA073146R1
E4.2H 3200 Ekip Hi-Touch LSI
1SDA072518R1
1SDA073148R1
E4.2H 3200 Ekip Hi-Touch LSIG
1SDA072519R1
1SDA073149R1
E4.2H 4000 Ekip Dip LI
1SDA072561R1
1SDA073191R1
E4.2H 4000 Ekip Dip LSI
1SDA072562R1
1SDA073192R1
E4.2H 4000 Ekip Dip LSIG
1SDA072563R1
1SDA073193R1
E4.2H 4000 Ekip Touch LI
1SDA072564R1
1SDA073194R1
E4.2H 4000 Ekip Touch LSI
1SDA072565R1
1SDA073195R1
E4.2H 4000 Ekip Touch LSIG
1SDA072566R1
1SDA073196R1
E4.2H 4000 Ekip Hi-Touch LSI
1SDA072568R1
1SDA073198R1
E4.2H 4000 Ekip Hi-Touch LSIG
1SDA072569R1
1SDA073199R1
9
ABB Catalogue | 1SDC200023D0201 | 9/29
Emax2_cap09.indd 29
15/04/2013 18:01:00
Automatic circuit-breakers
Withdrawable version for power distribution
SACE Emax E4.2V • Mobile part of withdrawable circuit-breaker (MP)
1SDC200667F001
Size
E4.2V
Iu
2000
2500
3200
Icu
Icw
(440 V) (1s)
Type
150
150
150
100
100
100
9
4000
150
100
3 Poles
4 Poles
Code
Code
E4.2V 2000 Ekip Dip LI
1SDA072451R1
1SDA073081R1
E4.2V 2000 Ekip Dip LSI
1SDA072452R1
1SDA073082R1
E4.2V 2000 Ekip Dip LSIG
1SDA072453R1
1SDA073083R1
E4.2V 2000 Ekip Touch LI
1SDA072454R1
1SDA073084R1
E4.2V 2000 Ekip Touch LSI
1SDA072455R1
1SDA073085R1
E4.2V 2000 Ekip Touch LSIG
1SDA072456R1
1SDA073086R1
E4.2V 2000 Ekip Hi-Touch LSI
1SDA072458R1
1SDA073088R1
E4.2V 2000 Ekip Hi-Touch LSIG
1SDA072459R1
1SDA073089R1
E4.2V 2500 Ekip Dip LI
1SDA072471R1
1SDA073101R1
E4.2V 2500 Ekip Dip LSI
1SDA072472R1
1SDA073102R1
E4.2V 2500 Ekip Dip LSIG
1SDA072473R1
1SDA073103R1
E4.2V 2500 Ekip Touch LI
1SDA072474R1
1SDA073104R1
E4.2V 2500 Ekip Touch LSI
1SDA072475R1
1SDA073105R1
E4.2V 2500 Ekip Touch LSIG
1SDA072476R1
1SDA073106R1
E4.2V 2500 Ekip Hi-Touch LSI
1SDA072478R1
1SDA073108R1
E4.2V 2500 Ekip Hi-Touch LSIG
1SDA072479R1
1SDA073109R1
E4.2V 3200 Ekip Dip LI
1SDA072521R1
1SDA073151R1
E4.2V 3200 Ekip Dip LSI
1SDA072522R1
1SDA073152R1
E4.2V 3200 Ekip Dip LSIG
1SDA072523R1
1SDA073153R1
E4.2V 3200 Ekip Touch LI
1SDA072524R1
1SDA073154R1
E4.2V 3200 Ekip Touch LSI
1SDA072525R1
1SDA073155R1
E4.2V 3200 Ekip Touch LSIG
1SDA072526R1
1SDA073156R1
E4.2V 3200 Ekip Hi-Touch LSI
1SDA072528R1
1SDA073158R1
E4.2V 3200 Ekip Hi-Touch LSIG
1SDA072529R1
1SDA073159R1
E4.2V 4000 Ekip Dip LI
1SDA072571R1
1SDA073201R1
E4.2V 4000 Ekip Dip LSI
1SDA072572R1
1SDA073202R1
E4.2V 4000 Ekip Dip LSIG
1SDA072573R1
1SDA073203R1
E4.2V 4000 Ekip Touch LI
1SDA072574R1
1SDA073204R1
E4.2V 4000 Ekip Touch LSI
1SDA072575R1
1SDA073205R1
E4.2V 4000 Ekip Touch LSIG
1SDA072576R1
1SDA073206R1
E4.2V 4000 Ekip Hi-Touch LSI
1SDA072578R1
1SDA073208R1
E4.2V 4000 Ekip Hi-Touch LSIG
1SDA072579R1
1SDA073209R1
9/30 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 30
15/04/2013 18:01:02
SACE Emax E6.2H-V • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
E6.2H
Iu
4000
5000
6300
E6.2V
4000
5000
6300
Icu
Icw
(440 V) (1s)
Type
100
100
100
150
150
150
100
100
100
100
100
100
3 Poles
4 Poles
Code
Code
E6.2H 4000 Ekip Dip LI
1SDA072581R1
1SDA073211R1
E6.2H 4000 Ekip Dip LSI
1SDA072582R1
1SDA073212R1
E6.2H 4000 Ekip Dip LSIG
1SDA072583R1
1SDA073213R1
E6.2H 4000 Ekip Touch LI
1SDA072584R1
1SDA073214R1
E6.2H 4000 Ekip Touch LSI
1SDA072585R1
1SDA073215R1
E6.2H 4000 Ekip Touch LSIG
1SDA072586R1
1SDA073216R1
E6.2H 4000 Ekip Hi-Touch LSI
1SDA072588R1
1SDA073218R1
E6.2H 4000 Ekip Hi-Touch LSIG
1SDA072589R1
1SDA073219R1
E6.2H 5000 Ekip Dip LI
1SDA072611R1
1SDA073241R1
E6.2H 5000 Ekip Dip LSI
1SDA072612R1
1SDA073242R1
E6.2H 5000 Ekip Dip LSIG
1SDA072613R1
1SDA073243R1
E6.2H 5000 Ekip Touch LI
1SDA072614R1
1SDA073244R1
E6.2H 5000 Ekip Touch LSI
1SDA072615R1
1SDA073245R1
E6.2H 5000 Ekip Touch LSIG
1SDA072616R1
1SDA073246R1
E6.2H 5000 Ekip Hi-Touch LSI
1SDA072618R1
1SDA073248R1
E6.2H 5000 Ekip Hi-Touch LSIG
1SDA072619R1
1SDA073249R1
E6.2H 6300 Ekip Dip LI
1SDA072641R1
1SDA073271R1
E6.2H 6300 Ekip Dip LSI
1SDA072642R1
1SDA073272R1
E6.2H 6300 Ekip Dip LSIG
1SDA072643R1
1SDA073273R1
E6.2H 6300 Ekip Touch LI
1SDA072644R1
1SDA073274R1
E6.2H 6300 Ekip Touch LSI
1SDA072645R1
1SDA073275R1
E6.2H 6300 Ekip Touch LSIG
1SDA072646R1
1SDA073276R1
E6.2H 6300 Ekip Hi-Touch LSI
1SDA072648R1
1SDA073278R1
E6.2H 6300 Ekip Hi-Touch LSIG
1SDA072649R1
1SDA073279R1
E6.2V 4000 Ekip Dip LI
1SDA072591R1
1SDA073221R1
E6.2V 4000 Ekip Dip LSI
1SDA072592R1
1SDA073222R1
E6.2V 4000 Ekip Dip LSIG
1SDA072593R1
1SDA073223R1
E6.2V 4000 Ekip Touch LI
1SDA072594R1
1SDA073224R1
E6.2V 4000 Ekip Touch LSI
1SDA072595R1
1SDA073225R1
E6.2V 4000 Ekip Touch LSIG
1SDA072596R1
1SDA073226R1
E6.2V 4000 Ekip Hi-Touch LSI
1SDA072598R1
1SDA073228R1
E6.2V 4000 Ekip Hi-Touch LSIG
1SDA072599R1
1SDA073229R1
E6.2V 5000 Ekip Dip LI
1SDA072621R1
1SDA073251R1
E6.2V 5000 Ekip Dip LSI
1SDA072622R1
1SDA073252R1
E6.2V 5000 Ekip Dip LSIG
1SDA072623R1
1SDA073253R1
E6.2V 5000 Ekip Touch LI
1SDA072624R1
1SDA073254R1
E6.2V 5000 Ekip Touch LSI
1SDA072625R1
1SDA073255R1
E6.2V 5000 Ekip Touch LSIG
1SDA072626R1
1SDA073256R1
E6.2V 5000 Ekip Hi-Touch LSI
1SDA072628R1
1SDA073258R1
E6.2V 5000 Ekip Hi-Touch LSIG
1SDA072629R1
1SDA073259R1
E6.2V 6300 Ekip Dip LI
1SDA072651R1
1SDA073281R1
E6.2V 6300 Ekip Dip LSI
1SDA072652R1
1SDA073282R1
E6.2V 6300 Ekip Dip LSIG
1SDA072653R1
1SDA073283R1
E6.2V 6300 Ekip Touch LI
1SDA072654R1
1SDA073284R1
E6.2V 6300 Ekip Touch LSI
1SDA072655R1
1SDA073285R1
E6.2V 6300 Ekip Touch LSIG
1SDA072656R1
1SDA073286R1
E6.2V 6300 Ekip Hi-Touch LSI
1SDA072658R1
1SDA073288R1
E6.2V 6300 Ekip Hi-Touch LSIG
1SDA072659R1
1SDA073289R1
9
ABB Catalogue | 1SDC200023D0201 | 9/31
Emax2_cap09.indd 31
15/04/2013 18:01:05
Automatic circuit-breakers
Withdrawable version for power distribution
SACE Emax E6.2X • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
E6.2X
Iu
4000
5000
6300
9
Icu
Icw
(440 V) (1s)
Type
200
200
200
120
120
120
3 Poles
4 Poles
Code
Code
E6.2X 4000 Ekip Dip LI
1SDA072601R1
1SDA073231R1
E6.2X 4000 Ekip Dip LSI
1SDA072602R1
1SDA073232R1
E6.2X 4000 Ekip Dip LSIG
1SDA072603R1
1SDA073233R1
E6.2X 4000 Ekip Touch LI
1SDA072604R1
1SDA073234R1
E6.2X 4000 Ekip Touch LSI
1SDA072605R1
1SDA073235R1
E6.2X 4000 Ekip Touch LSIG
1SDA072606R1
1SDA073236R1
E6.2X 4000 Ekip Hi-Touch LSI
1SDA072608R1
1SDA073238R1
E6.2X 4000 Ekip Hi-Touch LSIG
1SDA072609R1
1SDA073239R1
E6.2X 5000 Ekip Dip LI
1SDA072631R1
1SDA073261R1
E6.2X 5000 Ekip Dip LSI
1SDA072632R1
1SDA073262R1
E6.2X 5000 Ekip Dip LSIG
1SDA072633R1
1SDA073263R1
E6.2X 5000 Ekip Touch LI
1SDA072634R1
1SDA073264R1
E6.2X 5000 Ekip Touch LSI
1SDA072635R1
1SDA073265R1
E6.2X 5000 Ekip Touch LSIG
1SDA072636R1
1SDA073266R1
E6.2X 5000 Ekip Hi-Touch LSI
1SDA072638R1
1SDA073268R1
E6.2X 5000 Ekip Hi-Touch LSIG
1SDA072639R1
1SDA073269R1
E6.2X 6300 Ekip Dip LI
1SDA072661R1
1SDA073291R1
E6.2X 6300 Ekip Dip LSI
1SDA072662R1
1SDA073292R1
E6.2X 6300 Ekip Dip LSIG
1SDA072663R1
1SDA073293R1
E6.2X 6300 Ekip Touch LI
1SDA072664R1
1SDA073294R1
E6.2X 6300 Ekip Touch LSI
1SDA072665R1
1SDA073295R1
E6.2X 6300 Ekip Touch LSIG
1SDA072666R1
1SDA073296R1
E6.2X 6300 Ekip Hi-Touch LSI
1SDA072668R1
1SDA073298R1
E6.2X 6300 Ekip Hi-Touch LSIG
1SDA072669R1
1SDA073299R1
9/32 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 32
15/04/2013 18:01:08
SACE Emax E6.2H-V/f Full size • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
Iu
Icu (440 V)
Icw (1s)
Type
4 Poles
Code
E6.2H/f
4000
5000
6300
E6.2V/f
4000
5000
6300
100
100
100
150
150
150
100
100
100
100
100
100
E6.2H/f 4000 Ekip Dip LI
1SDA073301R1
E6.2H/f 4000 Ekip Dip LSI
1SDA073302R1
E6.2H/f 4000 Ekip Dip LSIG
1SDA073303R1
E6.2H/f 4000 Ekip Touch LI
1SDA073304R1
E6.2H/f 4000 Ekip Touch LSI
1SDA073305R1
E6.2H/f 4000 Ekip Touch LSIG
1SDA073306R1
E6.2H/f 4000 Ekip Hi-Touch LSI
1SDA073308R1
E6.2H/f 4000 Ekip Hi-Touch LSIG
1SDA073309R1
E6.2H/f 5000 Ekip Dip LI
1SDA073331R1
E6.2H/f 5000 Ekip Dip LSI
1SDA073332R1
E6.2H/f 5000 Ekip Dip LSIG
1SDA073333R1
E6.2H/f 5000 Ekip Touch LI
1SDA073334R1
E6.2H/f 5000 Ekip Touch LSI
1SDA073335R1
E6.2H/f 5000 Ekip Touch LSIG
1SDA073336R1
E6.2H/f 5000 Ekip Hi-Touch LSI
1SDA073338R1
E6.2H/f 5000 Ekip Hi-Touch LSIG
1SDA073339R1
E6.2H/f 6300 Ekip Dip LI
1SDA073361R1
E6.2H/f 6300 Ekip Dip LSI
1SDA073362R1
E6.2H/f 6300 Ekip Dip LSIG
1SDA073363R1
E6.2H/f 6300 Ekip Touch LI
1SDA073364R1
E6.2H/f 6300 Ekip Touch LSI
1SDA073365R1
E6.2H/f 6300 Ekip Touch LSIG
1SDA073366R1
E6.2H/f 6300 Ekip Hi-Touch LSI
1SDA073368R1
E6.2H/f 6300 Ekip Hi-Touch LSIG
1SDA073369R1
E6.2V/f 4000 Ekip Dip LI
1SDA073311R1
E6.2V/f 4000 Ekip Dip LSI
1SDA073312R1
E6.2V/f 4000 Ekip Dip LSIG
1SDA073313R1
E6.2V/f 4000 Ekip Touch LI
1SDA073314R1
E6.2V/f 4000 Ekip Touch LSI
1SDA073315R1
E6.2V/f 4000 Ekip Touch LSIG
1SDA073316R1
E6.2V/f 4000 Ekip Hi-Touch LSI
1SDA073318R1
E6.2V/f 4000 Ekip Hi-Touch LSIG
1SDA073319R1
E6.2V/f 5000 Ekip Dip LI
1SDA073341R1
E6.2V/f 5000 Ekip Dip LSI
1SDA073342R1
E6.2V/f 5000 Ekip Dip LSIG
1SDA073343R1
E6.2V/f 5000 Ekip Touch LI
1SDA073344R1
E6.2V/f 5000 Ekip Touch LSI
1SDA073345R1
E6.2V/f 5000 Ekip Touch LSIG
1SDA073346R1
E6.2V/f 5000 Ekip Hi-Touch LSI
1SDA073348R1
E6.2V/f 5000 Ekip Hi-Touch LSIG
1SDA073349R1
E6.2V/f 6300 Ekip Dip LI
1SDA073371R1
E6.2V/f 6300 Ekip Dip LSI
1SDA073372R1
E6.2V/f 6300 Ekip Dip LSIG
1SDA073373R1
E6.2V/f 6300 Ekip Touch LI
1SDA073374R1
E6.2V/f 6300 Ekip Touch LSI
1SDA073375R1
E6.2V/f 6300 Ekip Touch LSIG
1SDA073376R1
E6.2V/f 6300 Ekip Hi-Touch LSI
1SDA073378R1
E6.2V/f 6300 Ekip Hi-Touch LSIG
1SDA073379R1
9
ABB Catalogue | 1SDC200023D0201 | 9/33
Emax2_cap09.indd 33
15/04/2013 18:01:10
Automatic circuit-breakers
Withdrawable version for power distribution
SACE Emax E6.2X/f Full size • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
Iu
Icu (440 V)
Icw (1s)
Type
4 Poles
Code
E6.2X/f
4000
5000
6300
9
200
200
200
120
120
120
E6.2X/f 4000 Ekip Dip LI
1SDA073321R1
E6.2X/f 4000 Ekip Dip LSI
1SDA073322R1
E6.2X/f 4000 Ekip Dip LSIG
1SDA073323R1
E6.2X/f 4000 Ekip Touch LI
1SDA073324R1
E6.2X/f 4000 Ekip Touch LSI
1SDA073325R1
E6.2X/f 4000 Ekip Touch LSIG
1SDA073326R1
E6.2X/f 4000 Ekip Hi-Touch LSI
1SDA073328R1
E6.2X/f 4000 Ekip Hi-Touch LSIG
1SDA073329R1
E6.2X/f 5000 Ekip Dip LI
1SDA073351R1
E6.2X/f 5000 Ekip Dip LSI
1SDA073352R1
E6.2X/f 5000 Ekip Dip LSIG
1SDA073353R1
E6.2X/f 5000 Ekip Touch LI
1SDA073354R1
E6.2X/f 5000 Ekip Touch LSI
1SDA073355R1
E6.2X/f 5000 Ekip Touch LSIG
1SDA073356R1
E6.2X/f 5000 Ekip Hi-Touch LSI
1SDA073358R1
E6.2X/f 5000 Ekip Hi-Touch LSIG
1SDA073359R1
E6.2X/f 6300 Ekip Dip LI
1SDA073381R1
E6.2X/f 6300 Ekip Dip LSI
1SDA073382R1
E6.2X/f 6300 Ekip Dip LSIG
1SDA073383R1
E6.2X/f 6300 Ekip Touch LI
1SDA073384R1
E6.2X/f 6300 Ekip Touch LSI
1SDA073385R1
E6.2X/f 6300 Ekip Touch LSIG
1SDA073386R1
E6.2X/f 6300 Ekip Hi-Touch LSI
1SDA073388R1
E6.2X/f 6300 Ekip Hi-Touch LSIG
1SDA073389R1
9/34 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 34
15/04/2013 18:01:13
Automatic circuit-breakers
Fixed version for generators
1SDC200661F001
SACE Emax E1.2B-C-N-L • Front terminals (F)
Size
E1.2B
Iu
630
800
1000
1250
1600
E1.2C
42
E1.2B 630 Ekip G Touch LSIG
1SDA070707R1
1SDA071337R1
E1.2B 630 Ekip G Hi-Touch LSIG
1SDA070710R1
1SDA071340R1
42
42
42
42
42
42
42
42
42
50
42
800
50
42
1000
50
42
1600
50
50
42
42
250
66
50
630
66
50
800
66
50
1000
1250
1600
E1.2L
Type
630
1250
E1.2N
Icu
Icw
(440 V) (1s)
630
800
1000
1250
66
66
66
130
130
130
130
50
50
50
15
15
15
15
3 Poles
4 Poles
Code
Code
E1.2B 800 Ekip G Touch LSIG
1SDA070747R1
1SDA071377R1
E1.2B 800 Ekip G Hi-Touch LSIG
1SDA070750R1
1SDA071380R1
E1.2B 1000 Ekip G Touch LSIG
1SDA070787R1
1SDA071417R1
E1.2B 1000 Ekip G Hi-Touch LSIG 1SDA070790R1
1SDA071420R1
E1.2B 1250 Ekip G Touch LSIG
1SDA070827R1
1SDA071457R1
E1.2B 1250 Ekip G Hi-Touch LSIG 1SDA070830R1
1SDA071460R1
E1.2B 1600 Ekip G Touch LSIG
1SDA071497R1
1SDA070867R1
E1.2B 1600 Ekip G Hi-Touch LSIG 1SDA070870R1
1SDA071500R1
E1.2C 630 Ekip G Touch LSIG
1SDA070717R1
1SDA071347R1
E1.2C 630 Ekip G Hi-Touch LSIG
1SDA070720R1
1SDA071350R1
E1.2C 800 Ekip G Touch LSIG
1SDA070757R1
1SDA071387R1
E1.2C 800 Ekip G Hi-Touch LSIG
1SDA070760R1
1SDA071390R1
E1.2C 1000 Ekip G Touch LSIG
1SDA070797R1
1SDA071427R1
E1.2C 1000 Ekip G Hi-Touch LSIG 1SDA070800R1
1SDA071430R1
E1.2C 1250 Ekip G Touch LSIG
1SDA070837R1
1SDA071467R1
E1.2C 1250 Ekip G Hi-Touch LSIG 1SDA070840R1
1SDA071470R1
E1.2C 1600 Ekip G Touch LSIG
1SDA070877R1
1SDA071507R1
E1.2C 1600 Ekip G Hi-Touch LSIG 1SDA070880R1
1SDA071510R1
E1.2N 250 Ekip G Touch LSIG
1SDA070697R1
1SDA071327R1
E1.2N 250 Ekip G Hi-Touch LSIG
1SDA070700R1
1SDA071330R1
E1.2N 630 Ekip G Touch LSIG
1SDA070727R1
1SDA071357R1
E1.2N 630 Ekip G Hi-Touch LSIG
1SDA070730R1
1SDA071360R1
E1.2N 800 Ekip G Touch LSIG
1SDA070767R1
1SDA071397R1
E1.2N 800 Ekip G Hi-Touch LSIG
1SDA070770R1
1SDA071400R1
E1.2N 1000 Ekip G Touch LSIG
1SDA070807R1
1SDA071437R1
E1.2N 1000 Ekip G Hi-Touch LSIG 1SDA070810R1
1SDA071440R1
E1.2N 1250 Ekip G Touch LSIG
1SDA070847R1
1SDA071477R1
E1.2N 1250 Ekip G Hi-Touch LSIG 1SDA070850R1
1SDA071480R1
E1.2N 1600 Ekip G Touch LSIG
1SDA070887R1
1SDA071517R1
E1.2N 1600 Ekip G Hi-Touch LSIG 1SDA070890R1
1SDA071520R1
E1.2L 630 Ekip G Touch LSIG
1SDA070737R1
1SDA071367R1
E1.2L 630 Ekip G Hi-Touch LSIG
1SDA070740R1
1SDA071370R1
E1.2L 800 Ekip G Touch LSIG
1SDA070777R1
1SDA071407R1
E1.2L 800 Ekip G Hi-Touch LSIG
1SDA070780R1
1SDA071410R1
E1.2L 1000 Ekip G Touch LSIG
1SDA070817R1
1SDA071447R1
E1.2L 1000 Ekip G Hi-Touch LSIG
1SDA070820R1
1SDA071450R1
E1.2L 1250 Ekip G Touch LSIG
1SDA070857R1
1SDA071487R1
E1.2L 1250 Ekip G Hi-Touch LSIG
1SDA070860R1
1SDA071490R1
9
ABB Catalogue | 1SDC200023D0201 | 9/35
Emax2_cap09.indd 35
15/04/2013 18:01:13
Automatic circuit-breakers
Fixed version for generators
1SDC200662F001
SACE Emax E2.2B-N-S-H • Orientable rear terminals (HR)
Size
E2.2B
Iu
1600
2000
E2.2N
800
1000
1250
1600
E2.2S
42
E2.2B 1600 Ekip G Touch LSIG
42
66
66
66
66
42
42
66
66
66
66
66
66
2500
66
66
250
85
85
66
66
1000
85
66
1250
85
66
1600
2000
2500
E2.2H
Type
2000
800
9
Icu
Icw
(440 V) (1s)
800
1000
1250
1600
2000
2500
85
85
85
100
100
100
100
100
100
66
66
66
85
85
85
85
85
85
3 Poles
4 Poles
Code
Code
1SDA070987R1
1SDA071617R1
E2.2B 1600 Ekip G Hi-Touch LSIG 1SDA070990R1
1SDA071620R1
E2.2B 2000 Ekip G Touch LSIG
1SDA071027R1
1SDA071657R1
E2.2B 2000 Ekip G Hi-Touch LSIG 1SDA071030R1
1SDA071660R1
E2.2N 800 Ekip G Touch LSIG
1SDA070897R1
1SDA071527R1
E2.2N 800 Ekip G Hi-Touch LSIG
1SDA070900R1
1SDA071530R1
E2.2N 1000 Ekip G Touch LSIG
1SDA070927R1
1SDA071557R1
E2.2N 1000 Ekip G Hi-Touch LSIG 1SDA070930R1
1SDA071560R1
E2.2N 1250 Ekip G Touch LSIG
1SDA070957R1
1SDA071587R1
E2.2N 1250 Ekip G Hi-Touch LSIG 1SDA070960R1
1SDA071590R1
E2.2N 1600 Ekip G Touch LSIG
1SDA070997R1
1SDA071627R1
E2.2N 1600 Ekip G Hi-Touch LSIG 1SDA071000R1
1SDA071630R1
E2.2N 2000 Ekip G Touch LSIG
1SDA071037R1
1SDA071667R1
E2.2N 2000 Ekip G Hi-Touch LSIG 1SDA071040R1
1SDA071670R1
E2.2N 2500 Ekip G Touch LSIG
1SDA071067R1
1SDA071697R1
E2.2N 2500 Ekip G Hi-Touch LSIG 1SDA071070R1
1SDA071700R1
E2.2S 250 Ekip G Touch LSIG
1SDA073634R1
1SDA073644R1
E2.2S 250 Ekip G Hi-Touch LSIG
1SDA073637R1
1SDA073647R1
E2.2S 800 Ekip G Touch LSIG
1SDA070907R1
1SDA071537R1
E2.2S 800 Ekip G Hi-Touch LSIG
1SDA070910R1
1SDA071540R1
E2.2S 1000 Ekip G Touch LSIG
1SDA070937R1
1SDA071567R1
E2.2S 1000 Ekip G Hi-Touch LSIG 1SDA070940R1
1SDA071570R1
E2.2S 1250 Ekip G Touch LSIG
1SDA070967R1
1SDA071597R1
E2.2S 1250 Ekip G Hi-Touch LSIG 1SDA070970R1
1SDA071600R1
E2.2S 1600 Ekip G Touch LSIG
1SDA071007R1
1SDA071637R1
E2.2S 1600 Ekip G Hi-Touch LSIG 1SDA071010R1
1SDA071640R1
E2.2S 2000 Ekip G Touch LSIG
1SDA071047R1
1SDA071677R1
E2.2S 2000 Ekip G Hi-Touch LSIG 1SDA071050R1
1SDA071680R1
E2.2S 2500 Ekip G Touch LSIG
1SDA071077R1
1SDA071707R1
E2.2S 2500 Ekip G Hi-Touch LSIG 1SDA071080R1
1SDA071710R1
E2.2H 800 Ekip G Touch LSIG
1SDA070917R1
1SDA071547R1
E2.2H 800 Ekip G Hi-Touch LSIG
1SDA070920R1
1SDA071550R1
E2.2H 1000 Ekip G Touch LSIG
1SDA070947R1
1SDA071577R1
E2.2H 1000 Ekip G Hi-Touch LSIG 1SDA070950R1
1SDA071580R1
E2.2H 1250 Ekip G Touch LSIG
1SDA070977R1
1SDA071607R1
E2.2H 1250 Ekip G Hi-Touch LSIG 1SDA070980R1
1SDA071610R1
E2.2H 1600 Ekip G Touch LSIG
1SDA071017R1
1SDA071647R1
E2.2H 1600 Ekip G Hi-Touch LSIG 1SDA071020R1
1SDA071650R1
E2.2H 2000 Ekip G Touch LSIG
1SDA071057R1
1SDA071687R1
E2.2H 2000 Ekip G Hi-Touch LSIG 1SDA071060R1
1SDA071690R1
E2.2H 2500 Ekip G Touch LSIG
1SDA071087R1
1SDA071717R1
E2.2H 2500 Ekip G Hi-Touch LSIG 1SDA071090R1
1SDA071720R1
9/36 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 36
15/04/2013 18:01:14
1SDC200663F001
SACE Emax E4.2N-S-H-V • Orientable rear terminals (HR)
Size
E4.2N
Iu
3200
4000
E4.2S
3200
4000
E4.2H
3200
4000
E4.2V
Icu
Icw
(440 V) (1s)
Type
66
E4.2N 3200 Ekip G Touch LSIG
66
85
85
100
100
66
66
66
66
85
85
2000
150
100
2500
150
100
3200
4000
150
150
100
100
3 Poles
4 Poles
Code
Code
1SDA071147R1
1SDA071777R1
E4.2N 3200 Ekip G Hi-Touch LSIG 1SDA071150R1
1SDA071780R1
E4.2N 4000 Ekip G Touch LSIG
1SDA071197R1
1SDA071827R1
E4.2N 4000 Ekip G Hi-Touch LSIG 1SDA071200R1
1SDA071830R1
E4.2S 3200 Ekip G Touch LSIG
1SDA071157R1
1SDA071787R1
E4.2S 3200 Ekip G Hi-Touch LSIG 1SDA071160R1
1SDA071790R1
E4.2S 4000 Ekip G Touch LSIG
1SDA071207R1
1SDA071837R1
E4.2S 4000 Ekip G Hi-Touch LSIG 1SDA071210R1
1SDA071840R1
E4.2H 3200 Ekip G Touch LSIG
1SDA071167R1
1SDA071797R1
E4.2H 3200 Ekip G Hi-Touch LSIG 1SDA071170R1
1SDA071800R1
E4.2H 4000 Ekip G Touch LSIG
1SDA071217R1
1SDA071847R1
E4.2H 4000 Ekip G Hi-Touch LSIG 1SDA071220R1
1SDA071850R1
E4.2V 2000 Ekip G Touch LSIG
1SDA071107R1
1SDA071737R1
E4.2V 2000 Ekip G Hi-Touch LSIG 1SDA071110R1
1SDA071740R1
E4.2V 2500 Ekip G Touch LSIG
1SDA071127R1
1SDA071757R1
E4.2V 2500 Ekip G Hi-Touch LSIG 1SDA071130R1
1SDA071760R1
E4.2V 3200 Ekip G Touch LSIG
1SDA071177R1
1SDA071807R1
E4.2V 3200 Ekip G Hi-Touch LSIG 1SDA071180R1
1SDA071810R1
E4.2V 4000 Ekip G Touch LSIG
1SDA071227R1
1SDA071857R1
E4.2V 4000 Ekip G Hi-Touch LSIG 1SDA071230R1
1SDA071860R1
9
ABB Catalogue | 1SDC200023D0201 | 9/37
Emax2_cap09.indd 37
15/04/2013 18:01:14
Automatic circuit-breakers
Fixed version for generators
SACE Emax E6.2H-V-X • Orientable rear terminals (HR)
1SDC200664F001
Size
E6.2H
Iu
4000
5000
6300
E6.2V
4000
5000
6300
E6.2X
Icu
Icw
(440 V) (1s)
Type
100
E6.2H 4000 Ekip G Touch LSIG
100
100
150
150
150
100
100
100
100
100
100
4000
200
120
5000
200
120
6300
200
120
3 Poles
4 Poles
Code
Code
1SDA071237R1
1SDA071867R1
E6.2H 4000 Ekip G Hi-Touch LSIG 1SDA071240R1
1SDA071870R1
E6.2H 5000 Ekip G Touch LSIG
1SDA071267R1
1SDA071897R1
E6.2H 5000 Ekip G Hi-Touch LSIG 1SDA071270R1
1SDA071900R1
E6.2H 6300 Ekip G Touch LSIG
1SDA071297R1
1SDA071927R1
E6.2H 6300 Ekip G Hi-Touch LSIG 1SDA071300R1
1SDA071930R1
E6.2V 4000 Ekip G Touch LSIG
1SDA071247R1
1SDA071877R1
E6.2V 4000 Ekip G Hi-Touch LSIG 1SDA071250R1
1SDA071880R1
E6.2V 5000 Ekip G Touch LSIG
1SDA071277R1
1SDA071907R1
E6.2V 5000 Ekip G Hi-Touch LSIG 1SDA071280R1
1SDA071910R1
E6.2V 6300 Ekip G Touch LSIG
1SDA071307R1
1SDA071937R1
E6.2V 6300 Ekip G Hi-Touch LSIG 1SDA071310R1
1SDA071940R1
E6.2X 4000 Ekip G Touch LSIG
1SDA071257R1
1SDA071887R1
E6.2X 4000 Ekip G Hi-Touch LSIG 1SDA071260R1
1SDA071890R1
E6.2X 5000 Ekip G Touch LSIG
1SDA071287R1
1SDA071917R1
E6.2X 5000 Ekip G Hi-Touch LSIG 1SDA071290R1
1SDA071920R1
E6.2X 6300 Ekip G Touch LSIG
1SDA071317R1
1SDA071947R1
E6.2X 6300 Ekip G Hi-Touch LSIG 1SDA071320R1
1SDA071950R1
9
9/38 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 38
15/04/2013 18:01:15
SACE Emax E6.2H-V-X/f Full size • Orientable rear terminals (HR)
1SDC200664F001
Size
E6.2H/f
Iu
4000
5000
6300
E6.2V/f
Icw (1s)
100
100
100
100
100
100
150
100
5000
150
100
150
100
4000
200
120
5000
200
120
6300
200
Type
4 Poles
Code
4000
6300
E6.2X/f
Icu
(440 V)
120
E6.2H/f 4000 Ekip G Touch LSIG
1SDA071957R1
E6.2H/f 4000 Ekip G Hi-Touch LSIG
1SDA071960R1
E6.2H/f 5000 Ekip G Touch LSIG
1SDA071987R1
E6.2H/f 5000 Ekip G Hi-Touch LSIG
1SDA071990R1
E6.2H/f 6300 Ekip G Touch LSIG
1SDA072017R1
E6.2H/f 6300 Ekip G Hi-Touch LSIG
1SDA072020R1
E6.2V/f 4000 Ekip G Touch LSIG
1SDA071967R1
E6.2V/f 4000 Ekip G Hi-Touch LSIG
1SDA071970R1
E6.2V/f 5000 Ekip G Touch LSIG
1SDA071997R1
E6.2V/f 5000 Ekip G Hi-Touch LSIG
1SDA072000R1
E6.2V/f 6300 Ekip G Touch LSIG
1SDA072027R1
E6.2V/f 6300 Ekip G Hi-Touch LSIG
1SDA072030R1
E6.2X/f 4000 Ekip G Touch LSIG
1SDA071977R1
E6.2X/f 4000 Ekip G Hi-Touch LSIG
1SDA071980R1
E6.2X/f 5000 Ekip G Touch LSIG
1SDA072007R1
E6.2X/f 5000 Ekip G Hi-Touch LSIG
1SDA072010R1
E6.2X/f 6300 Ekip G Touch LSIG
1SDA072037R1
E6.2X/f 6300 Ekip G Hi-Touch LSIG
1SDA072040R1
9
ABB Catalogue | 1SDC200023D0201 | 9/39
Emax2_cap09.indd 39
15/04/2013 18:01:15
Automatic circuit-breakers
Withdrawable version for generators
1SDC200665F001
SACE Emax E1.2B-C-N-L • Mobile part of withdrawable circuit-breaker (MP)
Size
E1.2B
Iu
630
800
1000
1250
1600
E1.2C
630
E1.2B 630 Ekip G Touch LSIG
1SDA072057R1
1SDA072687R1
E1.2B 630 Ekip G Hi-Touch LSIG
1SDA072060R1
1SDA072690R1
42
42
42
42
50
42
42
42
42
42
42
42
1000
50
42
50
50
42
42
250
66
50
630
66
50
800
1000
1250
1600
E1.2L
42
50
1600
9
Type
800
1250
E1.2N
Icu
Icw
(440 V) (1s)
630
800
1000
1250
66
66
66
66
130
130
130
130
50
50
50
50
15
15
15
15
3 Poles
4 Poles
Code
Code
E1.2B 800 Ekip G Touch LSIG
1SDA072097R1
1SDA072727R1
E1.2B 800 Ekip G Hi-Touch LSIG
1SDA072100R1
1SDA072730R1
E1.2B 1000 Ekip G Touch LSIG
1SDA072137R1
1SDA072767R1
E1.2B 1000 Ekip G Hi-Touch LSIG 1SDA072140R1
1SDA072770R1
E1.2B 1250 Ekip G Touch LSIG
1SDA072177R1
1SDA072807R1
E1.2B 1250 Ekip G Hi-Touch LSIG 1SDA072180R1
1SDA072810R1
E1.2B 1600 Ekip G Touch LSIG
1SDA072217R1
1SDA072847R1
E1.2B 1600 Ekip G Hi-Touch LSIG 1SDA072220R1
1SDA072850R1
E1.2C 630 Ekip G Touch LSIG
1SDA072067R1
1SDA072697R1
E1.2C 630 Ekip G Hi-Touch LSIG
1SDA072070R1
1SDA072700R1
E1.2C 800 Ekip G Touch LSIG
1SDA072107R1
1SDA072737R1
E1.2C 800 Ekip G Hi-Touch LSIG
1SDA072110R1
1SDA072740R1
E1.2C 1000 Ekip G Touch LSIG
1SDA072147R1
1SDA072777R1
E1.2C 1000 Ekip G Hi-Touch LSIG 1SDA072150R1
1SDA072780R1
E1.2C 1250 Ekip G Touch LSIG
1SDA072187R1
1SDA072817R1
E1.2C 1250 Ekip G Hi-Touch LSIG 1SDA072190R1
1SDA072820R1
E1.2C 1600 Ekip G Touch LSIG
1SDA072227R1
1SDA072857R1
E1.2C 1600 Ekip G Hi-Touch LSIG 1SDA072230R1
1SDA072860R1
E1.2N 250 Ekip G Touch LSIG
1SDA072047R1
1SDA072677R1
E1.2N 250 Ekip G Hi-Touch LSIG
1SDA072050R1
1SDA072680R1
E1.2N 630 Ekip G Touch LSIG
1SDA072077R1
1SDA072707R1
E1.2N 630 Ekip G Hi-Touch LSIG
1SDA072080R1
1SDA072710R1
E1.2N 800 Ekip G Touch LSIG
1SDA072117R1
1SDA072747R1
E1.2N 800 Ekip G Hi-Touch LSIG
1SDA072120R1
1SDA072750R1
E1.2N 1000 Ekip G Touch LSIG
1SDA072157R1
1SDA072787R1
E1.2N 1000 Ekip G Hi-Touch LSIG 1SDA072160R1
1SDA072790R1
E1.2N 1250 Ekip G Touch LSIG
1SDA072197R1
1SDA072827R1
E1.2N 1250 Ekip G Hi-Touch LSIG 1SDA072200R1
1SDA072830R1
E1.2N 1600 Ekip G Touch LSIG
1SDA072237R1
1SDA072867R1
E1.2N 1600 Ekip G Hi-Touch LSIG 1SDA072240R1
1SDA072870R1
E1.2L 630 Ekip G Touch LSIG
1SDA072087R1
1SDA072717R1
E1.2L 630 Ekip G Hi-Touch LSIG
1SDA072090R1
1SDA072720R1
E1.2L 800 Ekip G Touch LSIG
1SDA072127R1
1SDA072757R1
E1.2L 800 Ekip G Hi-Touch LSIG
1SDA072130R1
1SDA072760R1
E1.2L 1000 Ekip G Touch LSIG
1SDA072167R1
1SDA072797R1
E1.2L 1000 Ekip G Hi-Touch LSIG
1SDA072170R1
1SDA072800R1
E1.2L 1250 Ekip G Touch LSIG
1SDA072207R1
1SDA072837R1
E1.2L 1250 Ekip G Hi-Touch LSIG
1SDA072210R1
1SDA072840R1
9/40 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 40
15/04/2013 18:01:16
SACE Emax E2.2B-N-S-H • Mobile part of withdrawable circuit-breaker (MP)
1SDC200666F001
Size
E2.2B
Iu
1600
2000
E2.2N
800
1000
1250
1600
E2.2S
Type
42
E2.2B 1600 Ekip G Touch LSIG
42
66
66
66
66
42
42
66
66
66
66
2000
66
66
2500
66
66
250
800
85
85
66
66
1000
85
66
1250
85
66
1600
85
66
2000
2500
E2.2H
Icu
Icw
(440 V) (1s)
800
1000
1250
1600
2000
2500
85
85
100
100
100
100
100
100
66
66
85
85
85
85
85
85
3 Poles
4 Poles
Code
Code
1SDA072337R1
1SDA072967R1
E2.2B 1600 Ekip G Hi-Touch LSIG 1SDA072340R1
1SDA072970R1
E2.2B 2000 Ekip G Touch LSIG
1SDA072377R1
1SDA073007R1
E2.2B 2000 Ekip G Hi-Touch LSIG 1SDA072380R1
1SDA073010R1
E2.2N 800 Ekip G Touch LSIG
1SDA072247R1
1SDA072877R1
E2.2N 800 Ekip G Hi-Touch LSIG
1SDA072250R1
1SDA072880R1
E2.2N 1000 Ekip G Touch LSIG
1SDA072277R1
1SDA072907R1
E2.2N 1000 Ekip G Hi-Touch LSIG 1SDA072280R1
1SDA072910R1
E2.2N 1250 Ekip G Touch LSIG
1SDA072307R1
1SDA072937R1
E2.2N 1250 Ekip G Hi-Touch LSIG 1SDA072310R1
1SDA072940R1
E2.2N 1600 Ekip G Touch LSIG
1SDA072347R1
1SDA072977R1
E2.2N 1600 Ekip G Hi-Touch LSIG 1SDA072350R1
1SDA072980R1
E2.2N 2000 Ekip G Touch LSIG
1SDA072387R1
1SDA073017R1
E2.2N 2000 Ekip G Hi-Touch LSIG 1SDA072390R1
1SDA073020R1
E2.2N 2500 Ekip G Touch LSIG
1SDA072417R1
1SDA073047R1
E2.2N 2500 Ekip G Hi-Touch LSIG 1SDA072420R1
1SDA073050R1
E2.2S 250 Ekip G Touch LSIG
1SDA073654R1
1SDA073664R1
E2.2S 250 Ekip G Hi-Touch LSIG
1SDA073657R1
1SDA073667R1
E2.2S 800 Ekip G Touch LSIG
1SDA072257R1
1SDA072887R1
E2.2S 800 Ekip G Hi-Touch LSIG
1SDA072260R1
1SDA072890R1
E2.2S 1000 Ekip G Touch LSIG
1SDA072287R1
1SDA072917R1
E2.2S 1000 Ekip G Hi-Touch LSIG 1SDA072290R1
1SDA072920R1
E2.2S 1250 Ekip G Touch LSIG
1SDA072317R1
1SDA072947R1
E2.2S 1250 Ekip G Hi-Touch LSIG 1SDA072320R1
1SDA072950R1
E2.2S 1600 Ekip G Touch LSIG
1SDA072357R1
1SDA072987R1
E2.2S 1600 Ekip G Hi-Touch LSIG 1SDA072360R1
1SDA072990R1
E2.2S 2000 Ekip G Touch LSIG
1SDA072397R1
1SDA073027R1
E2.2S 2000 Ekip G Hi-Touch LSIG 1SDA072400R1
1SDA073030R1
E2.2S 2500 Ekip G Touch LSIG
1SDA072427R1
1SDA073057R1
E2.2S 2500 Ekip G Hi-Touch LSIG 1SDA072430R1
1SDA073060R1
E2.2H 800 Ekip G Touch LSIG
1SDA072267R1
1SDA072897R1
E2.2H 800 Ekip G Hi-Touch LSIG
1SDA072270R1
1SDA072900R1
E2.2H 1000 Ekip G Touch LSIG
1SDA072297R1
1SDA072927R1
E2.2H 1000 Ekip G Hi-Touch LSIG 1SDA072300R1
1SDA072930R1
E2.2H 1250 Ekip G Touch LSIG
1SDA072327R1
1SDA072957R1
E2.2H 1250 Ekip G Hi-Touch LSIG 1SDA072330R1
1SDA072960R1
E2.2H 1600 Ekip G Touch LSIG
1SDA072367R1
1SDA072997R1
E2.2H 1600 Ekip G Hi-Touch LSIG 1SDA072370R1
1SDA073000R1
E2.2H 2000 Ekip G Touch LSIG
1SDA072407R1
1SDA073037R1
E2.2H 2000 Ekip G Hi-Touch LSIG 1SDA072410R1
1SDA073040R1
E2.2H 2500 Ekip G Touch LSIG
1SDA072437R1
1SDA073067R1
E2.2H 2500 Ekip G Hi-Touch LSIG 1SDA072440R1
1SDA073070R1
9
ABB Catalogue | 1SDC200023D0201 | 9/41
Emax2_cap09.indd 41
15/04/2013 18:01:18
Automatic circuit-breakers
Withdrawable version for generators
SACE Emax E4.2N-S-H-V • Mobile part of withdrawable circuit-breaker (MP)
1SDC200667F001
Size
E4.2N
Iu
3200
4000
E4.2S
3200
4000
E4.2H
3200
4000
E4.2V
Icu
Icw
(440 V) (1s)
Type
66
E4.2N 3200 Ekip G Touch LSIG
66
85
85
100
100
66
66
66
66
85
85
2000
150
100
2500
150
100
3200
4000
150
150
100
100
3 Poles
4 Poles
Code
Code
1SDA072497R1
1SDA073127R1
E4.2N 3200 Ekip G Hi-Touch LSIG 1SDA072500R1
1SDA073130R1
E4.2N 4000 Ekip G Touch LSIG
1SDA072547R1
1SDA073177R1
E4.2N 4000 Ekip G Hi-Touch LSIG 1SDA072550R1
1SDA073180R1
E4.2S 3200 Ekip G Touch LSIG
1SDA072507R1
1SDA073137R1
E4.2S 3200 Ekip G Hi-Touch LSIG 1SDA072510R1
1SDA073140R1
E4.2S 4000 Ekip G Touch LSIG
1SDA072557R1
1SDA073187R1
E4.2S 4000 Ekip G Hi-Touch LSIG 1SDA072560R1
1SDA073190R1
E4.2H 3200 Ekip G Touch LSIG
1SDA072517R1
1SDA073147R1
E4.2H 3200 Ekip G Hi-Touch LSIG 1SDA072520R1
1SDA073150R1
E4.2H 4000 Ekip G Touch LSIG
1SDA072567R1
1SDA073197R1
E4.2H 4000 Ekip G Hi-Touch LSIG 1SDA072570R1
1SDA073200R1
E4.2V 2000 Ekip G Touch LSIG
1SDA072457R1
1SDA073087R1
E4.2V 2000 Ekip G Hi-Touch LSIG 1SDA072460R1
1SDA073090R1
E4.2V 2500 Ekip G Touch LSIG
1SDA072477R1
1SDA073107R1
E4.2V 2500 Ekip G Hi-Touch LSIG 1SDA072480R1
1SDA073110R1
E4.2V 3200 Ekip G Touch LSIG
1SDA072527R1
1SDA073157R1
E4.2V 3200 Ekip G Hi-Touch LSIG 1SDA072530R1
1SDA073160R1
E4.2V 4000 Ekip G Touch LSIG
1SDA072577R1
1SDA073207R1
E4.2V 4000 Ekip G Hi-Touch LSIG 1SDA072580R1
1SDA073210R1
9
9/42 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 42
15/04/2013 18:01:19
SACE Emax E6.2H-V-X • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
E6.2H
Iu
4000
5000
6300
E6.2V
4000
5000
6300
E6.2X
Icu
Icw
(440 V) (1s)
Type
100
E6.2H 4000 Ekip G Touch LSIG
100
100
150
150
150
100
100
100
100
100
100
4000
200
120
5000
200
120
6300
200
120
3 Poles
4 Poles
Code
Code
1SDA072587R1
1SDA073217R1
E6.2H 4000 Ekip G Hi-Touch LSIG 1SDA072590R1
1SDA073220R1
E6.2H 5000 Ekip G Touch LSIG
1SDA072617R1
1SDA073247R1
E6.2H 5000 Ekip G Hi-Touch LSIG 1SDA072620R1
1SDA073250R1
E6.2H 6300 Ekip G Touch LSIG
1SDA072647R1
1SDA073277R1
E6.2H 6300 Ekip G Hi-Touch LSIG 1SDA072650R1
1SDA073280R1
E6.2V 4000 Ekip G Touch LSIG
1SDA072597R1
1SDA073227R1
E6.2V 4000 Ekip G Hi-Touch LSIG 1SDA072600R1
1SDA073230R1
E6.2V 5000 Ekip G Touch LSIG
1SDA072627R1
1SDA073257R1
E6.2V 5000 Ekip G Hi-Touch LSIG 1SDA072630R1
1SDA073260R1
E6.2V 6300 Ekip G Touch LSIG
1SDA072657R1
1SDA073287R1
E6.2V 6300 Ekip G Hi-Touch LSIG 1SDA072660R1
1SDA073290R1
E6.2X 4000 Ekip G Touch LSIG
1SDA072607R1
1SDA073237R1
E6.2X 4000 Ekip G Hi-Touch LSIG 1SDA072610R1
1SDA073240R1
E6.2X 5000 Ekip G Touch LSIG
1SDA072637R1
1SDA073267R1
E6.2X 5000 Ekip G Hi-Touch LSIG 1SDA072640R1
1SDA073270R1
E6.2X 6300 Ekip G Touch LSIG
1SDA072667R1
1SDA073297R1
E6.2X 6300 Ekip G Hi-Touch LSIG 1SDA072670R1
1SDA073300R1
9
ABB Catalogue | 1SDC200023D0201 | 9/43
Emax2_cap09.indd 43
15/04/2013 18:01:22
Automatic circuit-breakers
Withdrawable version per generators
SACE Emax E6.2H-V-X/f Full size • Mobile part of withdrawable circuit-breaker (MP)
1SDC200668F001
Size
E6.2H/f
Iu
4000
5000
6300
E6.2V/f
4000
5000
6300
E6.2X/f
Icu
(440 V)
Icw (1s)
100
100
100
100
150
150
150
100
100
100
100
100
200
120
5000
200
120
200
4 Poles
Code
4000
6300
Type
120
E6.2H/f 4000 Ekip G Touch LSIG
1SDA073307R1
E6.2H/f 4000 Ekip G Hi-Touch LSIG
1SDA073310R1
E6.2H/f 5000 Ekip G Touch LSIG
1SDA073337R1
E6.2H/f 5000 Ekip G Hi-Touch LSIG
1SDA073340R1
E6.2H/f 6300 Ekip G Touch LSIG
1SDA073367R1
E6.2H/f 6300 Ekip G Hi-Touch LSIG
1SDA073370R1
E6.2V/f 4000 Ekip G Touch LSIG
1SDA073317R1
E6.2V/f 4000 Ekip G Hi-Touch LSIG
1SDA073320R1
E6.2V/f 5000 Ekip G Touch LSIG
1SDA073347R1
E6.2V/f 5000 Ekip G Hi-Touch LSIG
1SDA073350R1
E6.2V/f 6300 Ekip G Touch LSIG
1SDA073377R1
E6.2V/f 6300 Ekip G Hi-Touch LSIG
1SDA073380R1
E6.2X/f 4000 Ekip G Touch LSIG
1SDA073327R1
E6.2X/f 4000 Ekip G Hi-Touch LSIG
1SDA073330R1
E6.2X/f 5000 Ekip G Touch LSIG
1SDA073357R1
E6.2X/f 5000 Ekip G Hi-Touch LSIG
1SDA073360R1
E6.2X/f 6300 Ekip G Touch LSIG
1SDA073387R1
E6.2X/f 6300 Ekip G Hi-Touch LSIG
1SDA073390R1
9
9/44 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 44
15/04/2013 18:01:24
Switch-disconnectors
Fixed version
1SDC200669F001
SACE Emax E1.2B-N/MS • Fixed terminals (F)
Size
E1.2B/MS
E1.2N/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
630
42
E1.2B/MS 630
1SDA073392R1
1SDA073431R1
800
42
E1.2B/MS 800
1SDA073394R1
1SDA073433R1
1000
42
E1.2B/MS 1000
1SDA073396R1
1SDA073435R1
1250
42
E1.2B/MS 1250
1SDA073398R1
1SDA073437R1
1600
42
E1.2B/MS 1600
1SDA073400R1
1SDA073439R1
250
50
E1.2N/MS 250
1SDA073391R1
1SDA073430R1
630
50
E1.2N/MS 630
1SDA073393R1
1SDA073432R1
800
50
E1.2N/MS 800
1SDA073395R1
1SDA073434R1
1000
50
E1.2N/MS 1000
1SDA073397R1
1SDA073436R1
1250
50
E1.2N/MS 1250
1SDA073399R1
1SDA073438R1
1600
50
E1.2N/MS 1600
1SDA073401R1
1SDA073440R1
1SDC200670F001
SACE Emax E2.2B-N-H/MS • Orientable rear terminals (HR)
3 Poles
4 Poles
Code
Code
1SDA073408R1
1SDA073447R1
Size
Iu
Icw (1s)
Type
E2.2B/MS
1600
42
E2.2B/MS 1600
2000
42
E2.2B/MS 2000
1SDA073411R1
1SDA073450R1
800
66
E2.2N/MS 800
1SDA073402R1
1SDA073441R1
1000
66
E2.2N/MS 1000
1SDA073404R1
1SDA073443R1
1250
66
E2.2N/MS 1250
1SDA073406R1
1SDA073445R1
1600
66
E2.2N/MS 1600
1SDA073409R1
1SDA073448R1
2000
66
E2.2N/MS 2000
1SDA073412R1
1SDA073451R1
2500
66
E2.2N/MS 2500
1SDA073414R1
1SDA073453R1
800
85
E2.2H/MS 800
1SDA073403R1
1SDA073442R1
1000
85
E2.2H/MS 1000
1SDA073405R1
1SDA073444R1
1250
85
E2.2H/MS 1250
1SDA073407R1
1SDA073446R1
1600
85
E2.2H/MS 1600
1SDA073410R1
1SDA073449R1
2000
85
E2.2H/MS 2000
1SDA073413R1
1SDA073452R1
2500
85
E2.2H/MS 2500
1SDA073415R1
1SDA073454R1
E2.2N/MS
E2.2H/MS
9
ABB Catalogue | 1SDC200023D0201 | 9/45
Emax2_cap09.indd 45
15/04/2013 18:01:25
Switch-disconnectors
Fixed version
SACE Emax E4.2N-H-V/MS • Orientable rear terminals (HR)
1SDC200671F001
Size
E4.2N/MS
E4.2H/MS
E4.2V/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
1SDA073457R1
3200
66
E4.2N/MS 3200
1SDA073418R1
4000
66
E4.2N/MS 4000
1SDA073421R1
1SDA073460R1
3200
85
E4.2H/MS 3200
1SDA073419R1
1SDA073458R1
4000
85
E4.2H/MS 4000
1SDA073422R1
1SDA073461R1
2000
100
E4.2V/MS 2000
1SDA073416R1
1SDA073455R1
2500
100
E4.2V/MS 2500
1SDA073417R1
1SDA073456R1
3200
100
E4.2V/MS 3200
1SDA073420R1
1SDA073459R1
4000
100
E4.2V/MS 4000
1SDA073423R1
1SDA073462R1
SACE Emax E6.2H-X/MS • Orientable rear terminals (HR)
1SDC200672F001
Size
E6.2H/MS
E6.2X/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
4000
100
E6.2H/MS 4000
1SDA073424R1
1SDA073463R1
5000
100
E6.2H/MS 5000
1SDA073426R1
1SDA073465R1
6300
100
E6.2H/MS 6300
1SDA073428R1
1SDA073467R1
4000
120
E6.2X/MS 4000
1SDA073425R1
1SDA073464R1
5000
120
E6.2X/MS 5000
1SDA073427R1
1SDA073466R1
6300
120
E6.2X/MS 6300
1SDA073429R1
1SDA073468R1
9
9/46 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 46
15/04/2013 18:01:26
SACE Emax E6.2H-X/MS/f Full size • Orientable rear terminals (HR)
1SDC200672F001
Size
Iu
Icw (1s)
Type
4 Poles
Code
E6.2H/MS/f
E6.2X/MS/f
4000
100
E6.2H/MS/f 4000
1SDA073469R1
5000
100
E6.2H/MS/f 5000
1SDA073471R1
6300
100
E6.2H/MS/f 6300
1SDA073473R1
4000
120
E6.2X/MS/f 4000
1SDA073470R1
5000
120
E6.2X/MS/f 5000
1SDA073472R1
6300
120
E6.2X/MS/f 6300
1SDA073474R1
9
ABB Catalogue | 1SDC200023D0201 | 9/47
Emax2_cap09.indd 47
15/04/2013 18:01:26
Switch-disconnectors
Withdrawable version
SACE Emax E1.2B-N/MS • Mobile part of withdrawable circuit-breaker (MP)
1SDC200673F001
Size
E1.2B/MS
E1.2N/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
630
42
E1.2B/MS 630
1SDA073476R1
1SDA073515R1
800
42
E1.2B/MS 800
1SDA073478R1
1SDA073517R1
1000
42
E1.2B/MS 1000
1SDA073480R1
1SDA073519R1
1250
42
E1.2B/MS 1250
1SDA073482R1
1SDA073521R1
1600
42
E1.2B/MS 1600
1SDA073484R1
1SDA073523R1
250
50
E1.2N/MS 250
1SDA073475R1
1SDA073514R1
630
50
E1.2N/MS 630
1SDA073477R1
1SDA073516R1
800
50
E1.2N/MS 800
1SDA073479R1
1SDA073518R1
1000
50
E1.2N/MS 1000
1SDA073481R1
1SDA073520R1
1250
50
E1.2N/MS 1250
1SDA073483R1
1SDA073522R1
1600
50
E1.2N/MS 1600
1SDA073485R1
1SDA073524R1
1SDC200674F001
SACE Emax E2.2B-N-H/MS • Mobile part of withdrawable circuit-breaker (MP)
3 Poles
4 Poles
Code
Code
1SDA073492R1
1SDA073531R1
E2.2B/MS 2000
1SDA073495R1
1SDA073534R1
66
E2.2N/MS 800
1SDA073486R1
1SDA073525R1
1000
66
E2.2N/MS 1000
1SDA073488R1
1SDA073527R1
1250
66
E2.2N/MS 1250
1SDA073490R1
1SDA073529R1
1600
66
E2.2N/MS 1600
1SDA073493R1
1SDA073532R1
2000
66
E2.2N/MS 2000
1SDA073496R1
1SDA073535R1
2500
66
E2.2N/MS 2500
1SDA073498R1
1SDA073537R1
800
85
E2.2H/MS 800
1SDA073487R1
1SDA073526R1
1000
85
E2.2H/MS 1000
1SDA073489R1
1SDA073528R1
1250
85
E2.2H/MS 1250
1SDA073491R1
1SDA073530R1
1600
85
E2.2H/MS 1600
1SDA073494R1
1SDA073533R1
2000
85
E2.2H/MS 2000
1SDA073497R1
1SDA073536R1
2500
85
E2.2H/MS 2500
1SDA073499R1
1SDA073538R1
Size
Iu
Icw (1s)
Type
E2.2B/MS
1600
42
E2.2B/MS 1600
2000
42
800
E2.2N/MS
9
E2.2H/MS
9/48 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 48
15/04/2013 18:01:29
SACE Emax E4.2N-H-V/MS • Mobile part of withdrawable circuit-breaker (MP)
1SDC200675F001
Size
E4.2N/MS
E4.2H/MS
E4.2V/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
1SDA073541R1
3200
66
E4.2N/MS 3200
1SDA073502R1
4000
66
E4.2N/MS 4000
1SDA073505R1
1SDA073544R1
3200
85
E4.2H/MS 3200
1SDA073503R1
1SDA073542R1
4000
85
E4.2H/MS 4000
1SDA073506R1
1SDA073545R1
2000
100
E4.2V/MS 2000
1SDA073500R1
1SDA073539R1
2500
100
E4.2V/MS 2500
1SDA073501R1
1SDA073540R1
3200
100
E4.2V/MS 3200
1SDA073504R1
1SDA073543R1
4000
100
E4.2V/MS 4000
1SDA073507R1
1SDA073546R1
SACE Emax E6.2H-X/MS • Mobile part of withdrawable circuit-breaker (MP)
1SDC200676F001
Size
E6.2H/MS
E6.2X/MS
Iu
Icw (1s)
Type
3 Poles
4 Poles
Code
Code
4000
100
E6.2H/MS 4000
1SDA073508R1
1SDA073547R1
5000
100
E6.2H/MS 5000
1SDA073510R1
1SDA073549R1
6300
100
E6.2H/MS 6300
1SDA073512R1
1SDA073551R1
4000
120
E6.2X/MS 4000
1SDA073509R1
1SDA073548R1
5000
120
E6.2X/MS 5000
1SDA073511R1
1SDA073550R1
6300
120
E6.2X/MS 6300
1SDA073513R1
1SDA073552R1
SACE Emax E6.2H-X/MS/f Full size • Mobile part of withdrawable circuit-breaker (MP)
Size
Iu
Icw (1s)
Type
4 Poles
E6.2H/MS/f
4000
100
E6.2H/MS/f 4000
1SDA073553R1
5000
100
E6.2H/MS/f 5000
1SDA073555R1
6300
100
E6.2H/MS/f 6300
1SDA073557R1
4000
120
E6.2X/MS/f 4000
1SDA073554R1
5000
120
E6.2X/MS/f 5000
1SDA073556R1
6300
120
E6.2X/MS/f 6300
1SDA073558R1
Code
E6.2X/MS/f
9
ABB Catalogue | 1SDC200023D0201 | 9/49
Emax2_cap09.indd 49
15/04/2013 18:01:33
Automatic circuit-breakers and switch-disconnectors
Version for applications up to 1150V AC
Size
Iu
Icu
(1150 V)
Icw
(1s)
Type
3 Poles
4 Poles
Code
Code
E1.2N/E
630
25
25
E1.2N/E 630 Upgrade Kit 1150V AC
1SDA074316R1
1SDA074321R1
E1.2N/E
800
25
25
E1.2N/E 800 Upgrade Kit 1150V AC
1SDA074317R1
1SDA074322R1
E1.2N/E
1000
25
25
E1.2N/E 1000 Upgrade Kit 1150V AC
1SDA074318R1
1SDA074323R1
E1.2N/E
1250
25
25
E1.2N/E 1250 Upgrade Kit 1150V AC
1SDA074319R1
1SDA074324R1
E1.2N/E
1600
25
25
E1.2N/E 1600 Upgrade Kit 1150V AC
1SDA074320R1
1SDA074325R1
E2.2H/E
800
30
30
E2.2H/E 800 Upgrade Kit 1150V AC
1SDA074326R1
1SDA074332R1
E2.2H/E
1000
30
30
E2.2H/E 1000 Upgrade Kit 1150V AC
1SDA074327R1
1SDA074333R1
E2.2H/E
1250
30
30
E2.2H/E 1250 Upgrade Kit 1150V AC
1SDA074328R1
1SDA074334R1
E2.2H/E
1600
30
30
E2.2H/E 1600 Upgrade Kit 1150V AC
1SDA074329R1
1SDA074335R1
E2.2H/E
2000
30
30
E2.2H/E 2000 Upgrade Kit 1150V AC
1SDA074330R1
1SDA074336R1
E2.2H/E
2500
30
30
E2.2H/E 2500 Upgrade Kit 1150V AC
1SDA074331R1
1SDA074337R1
E4.2H/E
3200
50
50
E4.2H/E 3200 Upgrade Kit 1150V AC
1SDA074338R1
1SDA074340R1
E4.2H/E
4000
50
50
E4.2H/E 4000 Upgrade Kit 1150V AC
1SDA074339R1
1SDA074341R1
E6.2X/E
4000
65
65
E6.2X/E 4000 Upgrade Kit 1150V AC
1SDA074342R1
1SDA074345R1
E6.2X/E
5000
65
65
E6.2X/E 5000 Upgrade Kit 1150V AC
1SDA074343R1
1SDA074346R1
E6.2X/E
6300
65
65
E6.2X/E 6300 Upgrade Kit 1150V AC
1SDA074344R1
1SDA074347R1
9
9/50 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 50
15/04/2013 18:01:33
Switch-disconnectors
Fixed version for applications up to 1000V DC
Size
Iu
Icu
(1000 V)
Icw
(1s)
Type
3 Poles
4 Poles
Code
Code
E1.2N/DC/MS
800
E1.2N/DC/MS 800A 750-1000V DC
1SDA074381R1
1SDA074382R1
E1.2N/DC/MS
1250
E1.2N/DC/MS 1250A 750-1000V DC
1SDA074383R1
1SDA074384R1
E2.2S/DC/MS
1250
E2.2S/DC/MS 1250A 750-1000V DC
1SDA074389R1
1SDA074390R1
E2.2S/DC/MS
1600
E2.2S/DC/MS 1600A 750-1000V DC
1SDA074391R1
1SDA074392R1
E2.2S/DC/MS
2000
E2.2S/DC/MS 2000A 750-1000V DC
1SDA074393R1
1SDA074394R1
E2.2S/DC/MS
2500
E2.2S/DC/MS 2500A 750-1000V DC
1SDA074395R1
1SDA074396R1
E4.2H/DC/MS
1250
E4.2H/DC/MS 1250A 750-1000V DC
1SDA074405R1
1SDA074406R1
E4.2H/DC/MS
1600
E4.2H/DC/MS 1600A 750-1000V DC
1SDA074407R1
1SDA074408R1
E4.2H/DC/MS
2000
E4.2H/DC/MS 2000A 750-1000V DC
1SDA074409R1
1SDA074410R1
E4.2H/DC/MS
2500
E4.2H/DC/MS 2500A 750-1000V DC
1SDA074411R1
1SDA074412R1
E4.2H/DC/MS
3200
E4.2H/DC/MS 3200A 750-1000V DC
1SDA074413R1
1SDA074414R1
E4.2H/DC/MS
4000
E4.2H/DC/MS 4000A 750-1000V DC
1SDA074415R1
1SDA074416R1
E6.2X/DC/MS
4000
E6.2X/DC/MS 4000A 750-1000V DC
1SDA074429R1
1SDA074430R1
E6.2X/DC/MS
5000
E6.2X/DC/MS 5000A 750-1000V DC
1SDA074431R1
1SDA074432R1
E6.2X/DC/MS
6300
E6.2X/DC/MS 6300A 750-1000V DC
1SDA074433R1
1SDA074434R1
9
ABB Catalogue | 1SDC200023D0201 | 9/51
Emax2_cap09.indd 51
15/04/2013 18:01:33
Switch-disconnectors
Withdrawable version for applications up to 1000V DC
Withdrawable version - Mobile part
Size
Iu
Icu
(1000 V)
Icw
(1s)
Type
3 Poles
4 Poles
Code
Code
E1.2N/DC/MS
800
E1.2N/DC/MS 800A 750-1000VDC
1SDA074385R1
1SDA074386R1
E1.2N/DC/MS
1250
E1.2N/DC/MS 1250A 750-1000VDC
1SDA074387R1
1SDA074388R1
E2.2S/DC/MS
1250
E2.2S/DC/MS 1250A 750-1000VDC
1SDA074397R1
1SDA074398R1
E2.2S/DC/MS
1600
E2.2S/DC/MS 1600A 750-1000VDC
1SDA074399R1
1SDA074400R1
E2.2S/DC/MS
2000
E2.2S/DC/MS 2000A 750-1000VDC
1SDA074401R1
1SDA074402R1
E2.2S/DC/MS
2500
E2.2S/DC/MS 2500A 750-1000VDC
1SDA074403R1
1SDA074404R1
E4.2H/DC/MS
1250
E4.2H/DC/MS 1250A 750-1000VDC
1SDA074417R1
1SDA074418R1
E4.2H/DC/MS
1600
E4.2H/DC/MS 1600A 750-1000VDC
1SDA074419R1
1SDA074420R1
E4.2H/DC/MS
2000
E4.2H/DC/MS 2000A 750-1000VDC
1SDA074421R1
1SDA074422R1
E4.2H/DC/MS
2500
E4.2H/DC/MS 2500A 750-1000VDC
1SDA074423R1
1SDA074424R1
E4.2H/DC/MS
3200
E4.2H/DC/MS 3200A 750-1000VDC
1SDA074425R1
1SDA074426R1
E4.2H/DC/MS
4000
E4.2H/DC/MS 4000A 750-1000VDC
1SDA074427R1
1SDA074428R1
E6.2X/DC/MS
4000
E6.2X/DC/MS 4000A 750-1000VDC
1SDA074435R1
1SDA074436R1
E6.2X/DC/MS
5000
E6.2X/DC/MS 5000A 750-1000VDC
1SDA074437R1
1SDA074438R1
E6.2X/DC/MS
6300
E6.2X/DC/MS 6300A 750-1000VDC
1SDA074439R1
1SDA074440R1
Withdrawable version - Fixed part
Size
9
Iu
Type of terminal
Type
3 Poles
4 Poles
Code
Code
E1.2
1600
HR - HR
E1.2DC W FP Iu=1600 HR HR
1SDA073923R1
1SDA073924R1
E2.2
2000
HR - HR
E2.2DC W FP Iu=2000 HR HR
1SDA073925R1
1SDA073926R1
E2.2
2500
HR - HR
E2.2DC W FP Iu=2500 HR HR
1SDA073927R1
1SDA073928R1
E4.2
3200
HR - HR
E4.2DC W FP Iu=3200 HR HR
1SDA073929R1
1SDA073930R1
E4.2 / E4.2V
4000
HR - HR
E4.2DC W FP Iu=4000 or V HR HR version
1SDA073931R1
1SDA073932R1
E6.2
5000
HR - HR
E6.2DC W FP Iu=5000 HR HR
1SDA073933R1
E6.2/f
5000
HR - HR
E6.2DC W FP Iu=5000 HR HR
E6.2 / E6.2X
6300
HR - HR
E6.2DC W FP Iu=6300 HR HR
E6.2/f / E6.2X/f
6300
HR - HR
E6.2DC W FP Iu=6300 HR HR
1SDA073935R1
1SDA073936R1
1SDA073938R1
9/52 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 52
15/04/2013 18:01:33
Derived versions
Sectionalizing truck - CS
Size
Iu
Type
3 poles
4 poles
Code
Code
E2.2/CS
2500
E2.2/CS 2500 MP 3p
1SDA074348R1
1SDA074349R1
E4.2/CS
4000
E4.2/CS 4000 MP 3p
1SDA074350R1
1SDA074351R1
E6.2/CS
6300
E6.2/CS 6300 MP 3p
1SDA074352R1
1SDA074353R1
Earthing truck - MT
Size
Iu
Type
3 poles
4 poles
Code
Code
E2.2 MT
2500
E2.2MT 2500 MP Earth connection from upper terminals
1SDA074354R1
1SDA074355R1
E4.2 MT
4000
E4.2MT 4000 MP Earth connection from upper terminals
1SDA074356R1
1SDA074357R1
E6.2 MT
6300
E6.2MT 6300 MP Earth connection from upper terminals
1SDA074358R1
1SDA074359R1
E2.2 MT
2500
E2.2MT 2500 MP Earth connection from lower terminals
1SDA074360R1
1SDA074361R1
E4.2 MT
4000
E4.2MT 4000 MP Earth connection from lower terminals
1SDA074362R1
1SDA074363R1
E6.2 MT
6300
E6.2MT 6300 MP Earth connection from lower terminals
1SDA074364R1
1SDA074365R1
3 poles
4 poles
Earthing switch with making capacity - MTP
Size
Iu
Type
Code
Code
E2.2 MTP
2500
E2.2MTP 2500 MP Earth connection from upper terminals
1SDA074366R1
1SDA074367R1
E4.2 MTP
4000
E4.2MTP 4000 MP Earth connection from upper terminals
1SDA074368R1
1SDA074369R1
E6.2 MTP
6300
E6.2MTP 6300 MP Earth connection from upper terminals
1SDA074370R1
1SDA074371R1
E2.2 MTP
2500
E2.2MTP 2500 MP Earth connection from lower terminals
1SDA074372R1
1SDA074373R1
E4.2 MTP
4000
E4.2MTP 4000 MP Earth connection from lower terminals
1SDA074374R1
1SDA074375R1
E6.2 MTP
6300
E6.2MTP 6300 MP Earth connection from lower terminals
1SDA074376R1
1SDA074377R1
9
Accessories for MT and MTP
Size
Type
Code
E2.2
Grounding clamp PF E2.2 for MT/MTP
1SDA074378R1
E4.2
Grounding clamp PF E4.2 for MT/MTP
1SDA074379R1
E6.2
Grounding clamp PF E6.2 for MT/MTP
1SDA074380R1
ABB Catalogue | 1SDC200023D0201 | 9/53
Emax2_cap09.indd 53
15/04/2013 18:01:33
Fixed parts
Performance
Iu
Type of
terminal
Type
3 Poles
4 Poles
Code
Code
E1.2
B, C, N, L
1600
HR - HR
E1.2 W FP Iu=1600 HR HR
1SDA073907R1
1SDA073908R1
E2.2
B, N, S, H
2000
HR - HR
E2.2 W FP Iu=2000 HR HR
1SDA073909R1
1SDA073910R1
E2.2
N, S, H
2500
HR - HR
E2.2 W FP Iu=2500 HR HR
1SDA073911R1
1SDA073912R1
E4.2
N, S, H
3200
HR - HR
E4.2 W FP Iu=3200 HR HR
1SDA073913R1
1SDA073914R1
E4.2
N, S, H, V
4000
HR - HR
E4.2 W FP Iu=4000 or V HR HR version
1SDA073915R1
1SDA073916R1
E6.2
H, V
5000
HR - HR
E6.2 W FP Iu=5000 HR HR
1SDA073917R1
1SDA073918R1
E6.2/f
H, V
5000
HR - HR
E6.2 W FP Iu=5000 HR HR
E6.2
H, V, X
6300
HR - HR
E6.2X W FP Iu=6300 or X HR HR version
E6.2/f
H, V, X
6300
HR - HR
E6.2 W FP Iu=6300 or X HR HR version
1SDA073919R1
1SDA073920R1
1SDA073921R1
1SDA073922R1
1SDC200679F001
1SDC200678F001
1SDC200677F001
Size
1SDC200680F001
9
9/54 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 54
15/04/2013 18:01:42
Accessories
Electrical accessories
1SDC200510F001
First and second opening release - YO
Size
Type
Code
E1.2..E6.2
YO E1.2..E6.2 24V AC/DC
1SDA073668R1
E1.2..E6.2
YO E1.2..E6.2 30V AC/DC
1SDA073669R1
E1.2..E6.2
YO E1.2..E6.2 48V AC/DC
1SDA073670R1
E1.2..E6.2
YO E1.2..E6.2 60V AC/DC
1SDA073671R1
E1.2..E6.2
YO E1.2..E6.2 110-120V AC/DC
1SDA073672R1
E1.2..E6.2
YO E1.2..E6.2 120-127V AC/DC
1SDA073673R1
E1.2..E6.2
YO E1.2..E6.2 220-240V AC/DC
1SDA073674R1
E1.2..E6.2
YO E1.2..E6.2 240-250V AC/DC
1SDA073675R1
E1.2..E6.2
YO E1.2..E6.2 380-400V AC
1SDA073677R1
E1.2..E6.2
YO E1.2..E6.2 415-440V AC
1SDA073678R1
E1.2..E6.2
YO E1.2..E6.2 480-500V AC
1SDA073679R1
First and second closing release- YC
Size
Type
Code
E1.2..E6.2
YC E1.2..E6.2 24V AC/DC
1SDA073681R1
E1.2..E6.2
YC E1.2..E6.2 30V AC/DC
1SDA073682R1
E1.2..E6.2
YC E1.2..E6.2 48V AC/DC
1SDA073683R1
E1.2..E6.2
YC E1.2..E6.2 60V AC/DC
1SDA073684R1
E1.2..E6.2
YC E1.2..E6.2 110-120V AC/DC
1SDA073685R1
E1.2..E6.2
YC E1.2..E6.2 120-127V AC/DC
1SDA073686R1
E1.2..E6.2
YC E1.2..E6.2 220-240V AC/DC
1SDA073687R1
E1.2..E6.2
YC E1.2..E6.2 240-250V AC/DC
1SDA073688R1
E1.2..E6.2
YC E1.2..E6.2 380-400V AC
1SDA073690R1
E1.2..E6.2
YC E1.2..E6.2 415-440V AC
1SDA073691R1
E1.2..E6.2
YC E1.2..E6.2 480-500V AC
1SDA073692R1
9
YO/YC test unit
Size
Type
Code
E1.2...E6.2
YO/YC test unit E1.2...E6.2
1SDA073707R1
Undervoltage release - YU
Size
Type
Code
E1.2..E6.2
YU E1.2..E6.2 24V AC/DC
1SDA073694R1
E1.2..E6.2
YU E1.2..E6.2 30V AC/DC
1SDA073695R1
E1.2..E6.2
YU E1.2..E6.2 48V AC/DC
1SDA073696R1
E1.2..E6.2
YU E1.2..E6.2 60V AC/DC
1SDA073697R1
E1.2..E6.2
YU E1.2..E6.2 110-120V AC/DC
1SDA073698R1
E1.2..E6.2
YU E1.2..E6.2 120-127V AC/DC
1SDA073699R1
E1.2..E6.2
YU E1.2..E6.2 220-240V AC/DC
1SDA073700R1
E1.2..E6.2
YU E1.2..E6.2 240-250V AC/DC
1SDA073701R1
E1.2..E6.2
YU E1.2..E6.2 380-400V AC
1SDA073703R1
E1.2..E6.2
YU E1.2..E6.2 415-440V AC
1SDA073704R1
E1.2..E6.2
YU E1.2..E6.2 480-500V AC
1SDA073705R1
Electronic time-delay device for undervoltage release - UVD
Size
Type
Code
E1.2...E6.2
24...30V DC
1SDA074623R1
E1.2...E6.2
48V AC/DC
1SDA074624R1
E1.2...E6.2
60V AC/DC
1SDA074625R1
E1.2...E6.2
110...127V AC/DC
1SDA074626R1
E1.2...E6.2
220...250V AC/DC
1SDA074627R1
ABB Catalogue | 1SDC200023D0201 | 9/55
Emax2_cap09.indd 55
15/04/2013 18:01:43
Accessories
Electrical accessories
1SDC200514F001
1SDC200513F001
1SDC200512F001
1SDC200511F001
Remote Reset - YR
1SDC200556F001
1SDC200555F001
9
Size
Type
Code
E1.2
YR 24V DC E1.2
1SDA073744R1
E1.2
YR 110V AC/DC E1.2
1SDA073745R1
E1.2
YR 250V AC/DC E1.2
1SDA073746R1
E2.2...E6.2
YR 24V DC E2.2...E6.2
1SDA073747R1
E2.2...E6.2
YR 110V AC/DC E2.2...E6.2
1SDA073748R1
E2.2...E6.2
YR 250V AC/DC E2.2...E6.2
1SDA073749R1
Motor - M
Size
Type
Code
E1.2
M E1.2 24-30V AC/DC
1SDA073708R1
E1.2
M E1.2 48-60V AC/DC
1SDA073709R1
E1.2
M E1.2 100-130V AC/DC
1SDA073710R1
E1.2
M E1.2 220-250V AC/DC
1SDA073711R1
E1.2
M E1.2 380-415V AC
1SDA073713R1
E1.2
M E1.2 440-480V AC
1SDA073714R1
E2.2...E6.2
M E2.2...E6.2 24-30V AC/DC
1SDA073722R1
E2.2...E6.2
M E2.2...E6.2 48-60V AC/DC
1SDA073723R1
E2.2...E6.2
M E2.2...E6.2 100-130V AC/DC
1SDA073724R1
E2.2...E6.2
M E2.2...E6.2 220-250V AC/DC
1SDA073725R1
E2.2...E6.2
M E2.2...E6.2 380-415V AC
1SDA073727R1
E2.2...E6.2
M E2.2...E6.2 440-480V AC
1SDA073728R1
E1.2
M E1.2 24-30V AC/DC + S33 M/2 24V DC
1SDA073715R1
E1.2
M E1.2 48-60V AC/DC + S33 M/2 24V DC
1SDA073716R1
E1.2
M E1.2 100-130V AC/DC + S33 M/2 24V DC
1SDA073717R1
E1.2
M E1.2 220-250V AC/DC + S33 M/2 24V DC
1SDA073718R1
E1.2
M E1.2 380-415V AC + S33 M/2 24V DC
1SDA073720R1
E1.2
M E1.2 440-480V AC + S33 M/2 24V DC
1SDA073721R1
E2.2...E6.2
M E2.2...E6.2 24-30V AC/DC + S33 M/2 24V DC
1SDA073729R1
E2.2...E6.2
M E2.2...E6.2 48-60V AC/DC + S33 M/2 24V DC
1SDA073730R1
E2.2...E6.2
M E2.2...E6.2 100-130V AC/DC + S33 M/2 24V DC
1SDA073731R1
E2.2...E6.2
M E2.2...E6.2 220-250V AC/DC + S33 M/2 24V DC
1SDA073732R1
E2.2...E6.2
M E2.2...E6.2 380-415V AC + S33 M/2 24V DC
1SDA073734R1
E2.2...E6.2
M E2.2...E6.2 440-480V AC + S33 M/2 24V DC
1SDA073735R1
Current sensor for neutral conductor outside the circuit-breaker
Size
Type
Code
E1.2
Ext CS N E1.2 E2.2 2000A
1SDA073736R1
E2.2
Ext CS N E2.2 2500A
1SDA073737R1
E4.2
Ext CS N E4.2 3200A
1SDA073738R1
E6.2
Ext CS N E4.2 4000A E6.2 50%
1SDA073739R1
E6.2
Ext CS N E6.2
1SDA073740R1
Homopolar toroid for the earthing conductor of main power supply
Size
Type
Code
E1.2..E6.2
Homopolar toroid E1.2 … E6.2
1SDA073743R1
1SDC200557F001
Toroid for differential protection
Size
Type
Code
E1.2 - E2.2 3p
Toroid RC E1.2, E2.2 3p
1SDA073741R1
E2.2 4p - E4.2
Toroid RC E2.2 4p, E4.2
1SDA073742R1
9/56 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 56
15/04/2013 18:01:45
1SDC200503F001
1SDC200505F001
1SDC200504F001
Open/closed auxiliary contacts - AUX
Type
Code
E1.2
AUX 4Q 400V E1.2
1SDA073750R1
E1.2
AUX 4Q 24V E1.2
1SDA073751R1
E1.2
AUX 2Q 400V + 2Q 24V E1.2
1SDA073752R1
E2.2...E6.2
AUX 4Q 400V E2.2...E6.2
1SDA073753R1
E2.2...E6.2
AUX 4Q 24V E2.2...E6.2
1SDA073754R1
E2.2...E6.2
AUX 2Q 400V + 2Q 24V E2.2...E6.2
1SDA073755R1
E2.2...E6.2
AUX 6Q 400V E2.2...E6.2
1SDA073756R1
E2.2...E6.2
AUX 6Q 24V E2.2...E6.2
1SDA073757R1
E2.2...E6.2
AUX 3Q 400V AC + 3Q 24V DC E2.2...E6.2
1SDA075973R1
E1.2
AUX 15Q 400V E1.2 *
1SDA073758R1
E1.2
AUX 15Q 24V E1.2 *
1SDA073759R1
E2.2...E6.2
AUX 15Q 400V E2.2...E6.2 *
1SDA073760R1
E2.2...E6.2
AUX 15Q 24V E2.2...E6.2 *
1SDA073761R1
* not compatible with mechanical locks on compartment doors or mechanical interlocks; must be ordered with interlock support.
1SDC200506F001
Auxiliary position contacts - AUP
1SDC200507F001
1SDC200508F001
Size
Size
Type
Code
E1.2
AUP 6 contacts 400V E1.2
1SDA073762R1
E1.2
AUP 6 contacts 24V E1.2
1SDA073763R1
E2.2...E6.2
AUP 5 contacts 400V E2.2...E6.2 - left set
1SDA073764R1
E2.2...E6.2
AUP 5 contacts 24V E2.2...E6.2 - left set
1SDA073765R1
E2.2...E6.2
AUP 5 suppl. contacts 400V E2.2...E6.2 - right set
1SDA073766R1
E2.2...E6.2
AUP 5 suppl. contacts 24V E2.2...E6.2 - right set
1SDA073767R1
E1.2
AUP Ekip aux. contacts position E1.2
1SDA073768R1
E2.2...E6.2
AUP Ekip aux. contacts position E2.2..E6.2
1SDA073769R1
9
Ready to close signalling contact- RTC
Size
Type
Code
E1.2
RTC 250V E1.2
1SDA073770R1
E1.2
RTC 24V E1.2
1SDA073771R1
E1.2
RTC Ekip 24V E1.2
1SDA073772R1
E2.2...E6.2
RTC 250V E2.2...E6.2
1SDA073773R1
E2.2...E6.2
RTC 24V E2.2...E6.2
1SDA073774R1
E2.2...E6.2
RTC Ekip 24V E2.2...E6.2
1SDA073775R1
Contact signalling tripping of Ekip protection trip unit - S51
Size
Type
Code
E1.2
S51 250V E1.2
1SDA073776R1
E1.2
S51 24V E1.2
1SDA073777R1
E2.2...E6.2
S51 250V E2.2...E6.2
1SDA073778R1
E2.2...E6.2
S51 24V E2.2...E6.2
1SDA073779R1
1SDC200681F001
Terminals for auxiliary connection
Size
Type
Code
E1.2..E6.2
Terminals 10 pcs
1SDA073906R1
ABB Catalogue | 1SDC200023D0201 | 9/57
Emax2_cap09.indd 57
15/04/2013 18:01:48
1SDC200524F001
Accessories
Mechanical accessories
Mechanical operation counter - MOC
Size
Type
Code
E1.2
MOC Mechanical operation counter
1SDA073780R1
E2.2...E6.2
MOC Mechanical operation counter
1SDA073781R1
1SDC200516F001
1SDC200515F001
Key lock in open position - KLC
9
Size
Type
Code
E1.2
KLC-D Bl. Key lock open E1.2
1SDA073782R1
E1.2
KLC-S Bl. Key lock open N.20005 E1.2
1SDA073783R1
E1.2
KLC-S Bl. Key lock open N.20006 E1.2
1SDA073784R1
E1.2
KLC-S Bl. Key lock open N.20007 E1.2
1SDA073785R1
E1.2
KLC-S Bl. Key lock open N.20008 E1.2
1SDA073786R1
E1.2
KLC-S Bl. Key lock open N.20009 E1.2
1SDA073787R1
E1.2
KLA Bl. Castell key lock open E1.2
1SDA073788R1
E1.2
KLA Bl. Kirk key lock open E1.2
1SDA073789R1
E1.2
KLA Bl. Ronis Profalux key lock open E1.2
1SDA073790R1
E2.2...E6.2
KLC-D Bl. Key lock open E2.2...E6.2
1SDA073791R1
E2.2...E6.2
KLC-S Bl. key lock AP N.20005 E2.2..E6.2
1SDA073792R1
E2.2...E6.2
KLC-S Bl. key lock AP N.20006 E2.2..E6.2
1SDA073793R1
E2.2...E6.2
KLC-S Bl. key lock AP N.20007 E2.2..E6.2
1SDA073794R1
E2.2...E6.2
KLC-S Bl. key lock AP N.20008 E2.2..E6.2
1SDA073795R1
E2.2...E6.2
KLC-S Bl. key lock AP N.20009 E2.2..E6.2
1SDA073796R1
E2.2...E6.2
KLA Bl. Castell key lock open E2.2...E6.2
1SDA073797R1
E2.2...E6.2
KLA Bl. AP Castell Kirk key lock E2.2..E6.2
1SDA073798R1
E2.2...E6.2
KLA Bl. AP Ronis Profalux key lock E2.2..E6.2
1SDA073799R1
1SDC200518F001
1SDC200517F001
Padlocks in open position - PLC
Size
Type
Code
E1.2
PLC E1.2 Bl. Padlocks in open position D=4mm
1SDA073800R1
E1.2
PLC E1.2 Bl. Padlocks in open position D=7mm
1SDA073801R1
E1.2
PLC E1.2 Bl. Padlocks in open position D=8mm
1SDA073802R1
E2.2...E6.2
PLC E2.2..E6.2 Bl. Padlocks in open position D=4mm
1SDA073803R1
E2.2...E6.2
PLC E2.2..E6.2 Bl. Padlocks in open position D=7mm
1SDA073804R1
E2.2...E6.2
PLC E2.2..E6.2 Bl. Padlocks in open position D=8mm
1SDA073805R1
9/58 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 58
15/04/2013 18:01:50
1SDC200519F001
1SDC200520F001
Key lock in racked-in / test / racked-out position- KLP
Size
Type
Code
E1.2
KLP-D Bl. Racked in/out E1.2 1st key
1SDA073822R1
E1.2
KLP-S Bl. Racked in/out N.20005 E1.2 1st key
1SDA073823R1
E1.2
KLP-S Bl. Racked in/out N.20006 E1.2 1st key
1SDA073824R1
E1.2
KLP-S Bl. Racked in/out N.20007 E1.2 1st key
1SDA073825R1
E1.2
KLP-S Bl. Racked in/out N.20008 E1.2 1st key
1SDA073826R1
E1.2
KLP-S Bl. Racked in/out N.20009 E1.2 1st key
1SDA073827R1
E1.2
KLP-D Bl. Racked in/out E1.2 2nd key
1SDA073828R1
E1.2
KLP-S Bl. Racked in/out N.20005 E1.2 2nd key
1SDA073829R1
E1.2
KLP-S Bl. Racked in/out N.20006 E1.2 2nd key
1SDA073830R1
E1.2
KLP-S Bl. Racked in/out N.20007 E1.2 2nd key
1SDA073831R1
E1.2
KLP-S Bl. Racked in/out N.20008 E1.2 2nd key
1SDA073832R1
E1.2
KLP-S Bl. Racked in/out N.20009 E1.2 2nd key
1SDA073833R1
E1.2
KLP-A Bl. Racked in/out RonProf Kirk E1.2 1st key
1SDA073834R1
E1.2
KLP-A Bl. Racked in/out RonProf Kirk E1.2 2nd key
1SDA073835R1
E1.2
KLP-A Bl. Racked in/out Castell E1.2 1st key
1SDA073836R1
E1.2
KLP-A Bl. Racked in/out Castell E1.2 2nd key
1SDA073837R1
E2.2...E6.2
KLP-D Bl. Racked in/out E2.2...E6.2 1st key
1SDA073806R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20005 E2.2..E6.2 1st key
1SDA073807R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20006 E2.2..E6.2 1st key
1SDA073808R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20007 E2.2..E6.2 1st key
1SDA073809R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20008 E2.2..E6.2 1st key
1SDA073810R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20009 E2.2..E6.2 1st key
1SDA073811R1
E2.2...E6.2
KLP-D Bl. Racked in/out E2.2...E6.2 2nd key
1SDA073812R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20005 E2.2..E6.2 2nd key
1SDA073813R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20006 E2.2..E6.2 2nd key
1SDA073814R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20007 E2.2..E6.2 2nd key
1SDA073815R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20008 E2.2..E6.2 2nd key
1SDA073816R1
E2.2...E6.2
KLP-S Bl. Racked in/out N.20009 E2.2..E6.2 2nd key
1SDA073817R1
E2.2...E6.2
KLP-A Bl. Racked in/out RoProKirk E2.2..E6.2 1st key
1SDA073818R1
E2.2...E6.2
KLP-A Bl. Racked in/out RoProKirk E2.2..E6.2 2nd key
1SDA073819R1
E2.2...E6.2
KLP-A Bl. Racked in/out Castell E2.2..E6.2 1st key
1SDA073820R1
E2.2...E6.2
KLP-A Bl. Racked in/out Castell E2.2..E6.2 2nd key
1SDA073821R1
9
1SDC200521F001
Accessory for supplementary lock in racked-out position
Size
Type
Code
E1.2
Suppl. locks in racked-out E1.2
1SDA073838R1
E2.2...E6.2
Suppl. locks in racked-out E2.2...E6.2
1SDA073839R1
Padlock in racked-in / test / racked-out position - PLP
Size
Type
Code
E1.2
PLP Bl. padlocks Racked in/out D=4/6/8mm E1.2
1SDA073840R1
E2.2...E6.2
PLP Bl. padlocks Racked in/out D=4/6/8mm E2.2..E6.2
1SDA073841R1
1SDC200522F001
External shutter lock- SLE
Size
Type
Code
E2.2
SLE Bl. shutter lock D=4/6/8mm E2.2
1SDA073842R1
E4.2
SLE Bl. shutter lock D=4/6/8mm E4.2
1SDA073843R1
E6.2
SLE Bl. shutter lock D=4/6/8mm E6.2
1SDA073844R1
ABB Catalogue | 1SDC200023D0201 | 9/59
Emax2_cap09.indd 59
15/04/2013 18:01:52
Accessories
Mechanical accessories
Lock for racking in / racking out the mobile part when the door is open - DLR
Size
Type
Code
E2.2
DLR E2.2
1SDA073845R1
E4.2
DLR E4.2
1SDA073846R1
E6.2
DLR E6.2
1SDA073847R1
1SDC200523F001
Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP
Size
Type
Code
E2.2...E6.2
DLP E2.2...E6.2
1SDA073849R1
Lock to prevent door opening when circuit-breaker is in closed position - DLC
Size
Type
Code
E1.2
DLC Interlock cable door E1.2
1SDA073850R1
E1.2
DLC Interlock direct door E1.2
1SDA073851R1
E2.2...E6.2
DLC Interlock cable door E2.2...E6.2
1SDA073852R1
E2.2...E6.2
DLC Interlock direct door E2.2…E6.2
1SDA073853R1
1SDC200525F001
1SDC200526F001
Protection device for opening and closing pushbuttons - PBC
9
Size
Type
Code
E1.2
PBC Prot. Pushbuttons AP/CH E1.2
1SDA073854R1
E1.2
PBC Prot. Pushbuttons AP/CH D=4mm E1.2
1SDA073855R1
E1.2
PBC Prot. Pushbuttons AP/CH D=7mm E1.2
1SDA073856R1
E1.2
PBC Prot. Pushbuttons AP/CH D=8mm E1.2
1SDA073857R1
E2.2...E6.2
PBC Prot. Pushbuttons AP/CH E2.2...E6.2
1SDA073858R1
E2.2...E6.2
PBC Prot. Pushbuttons AP/CH D=4mm E2.2..E6.2
1SDA073859R1
E2.2...E6.2
PBC Prot. Pushbuttons AP/CH D=7mm E2.2..E6.2
1SDA073860R1
E2.2...E6.2
PBC Prot. Pushbuttons AP/CH D=8mm E2.2..E6.2
1SDA073861R1
1SDC200529F001
1SDC200528F001
1SDC200527F001
Circuit-breaker flange
Size
Type
Code
E1.2
IP30 Flange E1.2 F
1SDA073862R1
E1.2
IP30 Flange E1.2 W
1SDA073863R1
E2.2...E6.2
IP30 Flange E2.2...E6.2 F
1SDA073864R1
E2.2...E6.2
IP30 Flange E2.2...E6.2 W
1SDA073865R1
E1.2
IP54 Flange different keys E1.2
1SDA073866R1
E2.2...E6.2
IP54 Flange different keys E2.2...E6.2
1SDA073867R1
E1.2
IP54 Flange key No. 20005 E1.2
1SDA073868R1
E2.2...E6.2
IP54 Flange key No. 20005 E2.2...E6.2
1SDA073869R1
E2.2...E6.2
Sealable trip unit cover
1SDA073870R1
High or low terminal covers- HTC/LTC
1SDC200530F001
Size
Type
3 poles
4 poles
Code
Code
E1.2
HTC high terminal covers E1.2 2pcs
1SDA073871R1
1SDA073872R1
E1.2
LTC low terminal covers E1.2 F 2pcs
1SDA073873R1
1SDA073874R1
E1.2
LTC low terminal covers E1.2 W 2pcs
1SDA073875R1
1SDA073876R1
1SDC200531F001
Separators - PB
Size
Type
Code
E1.2
PB Separators H=100mm 4pz E1.2 3P
1SDA073877R1
E1.2
PB Separators H=100mm 6pz E1.2 4P
1SDA073878R1
E1.2
PB Separators H=200mm 4pz E1.2 3P
1SDA073879R1
E1.2
PB Separators H=200mm 6pz E1.2 4P
1SDA073880R1
9/60 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 60
15/04/2013 18:01:55
Accessories
Mechanical interlock
Cables for mechanical interlock [Group 1]
Size
Type
Code
E1.2..E6.2
Type A horizontal
1SDA073881R1
E2.2..E6.2
Type B,C,D horizontal
1SDA073882R1
E1.2..E6.2
Type A vertical
1SDA073885R1
E2.2..E6.2
Type B,C,D vertical
1SDA073886R1
Order one type of cable for each interlock. The cable must be ordered on the fixed circuit-breaker or on the fixed part of withdrawable circuit-breaker.
Lever for mechanical interlock of fixed circuit-breaker or mobile part [Group 2]
Size
Type
3 Poles
4 Poles
Code
Code
E2.2
Lever for mechanical interlock
1SDA073889R1
1SDA073889R1
E4.2
Lever for mechanical interlock
1SDA073890R1
1SDA073890R1
E6.2
Lever for mechanical interlock
1SDA073891R1
1SDA073892R1
The lever for mechanical interlock is not required for E1.2
Support for mechanical interlock of fixed circuit-breaker [Group 3]
Size
Type
Code
E1.2
Type A
1SDA073893R1
E1.2
Type A - Installed on bottom plate
1SDA073894R1
E2.2 … E6.2
Type A / B / D
1SDA073895R1
E2.2 … E6.2
Type C
1SDA073897R1
Support for mechanical interlock of fixed part [Group 4]
Size
Type
Code
E1.2
Type A
1SDA073896R1
E2.2 … E6.2
Type A / B / D
1SDA073895R1
E2.2 … E6.2
Type C
1SDA073897R1
9
Automatic transfer switch
Size
Type
Code
E1.2..E6.2
ATS021
1SDA065523R1
E1.2..E6.2
ATS022
1SDA065524R1
ABB Catalogue | 1SDC200023D0201 | 9/61
Emax2_cap09.indd 61
15/04/2013 18:01:56
1SDC200476F001
1SDC200475F001
1SDC200480F001
1SDC200466F001
1SDC200446F001
Accessories
Ekip modules
Ekip electrical trip units - loose supply
Size
Type
Code
E1.2..E6.2
Ekip Dip LI
1SDA074194R1
E1.2..E6.2
Ekip Dip LSI
1SDA074195R1
E1.2..E6.2
Ekip Dip LSIG
1SDA074196R1
E1.2..E6.2
Ekip Touch LI
1SDA074197R1
E1.2..E6.2
Ekip Touch LSI
1SDA074198R1
E1.2..E6.2
Ekip Touch LSIG
1SDA074199R1
E1.2..E6.2
Ekip G Touch LSIG
1SDA074200R1
E1.2..E6.2
Ekip Hi-Touch LSI
1SDA074201R1
E1.2..E6.2
Ekip Hi-Touch LSIG
1SDA074202R1
E1.2..E6.2
Ekip G Hi-Touch LSIG
1SDA074203R1
E1.2..E6.2
Ekip LCD LI
1SDA074204R1
E1.2..E6.2
Ekip LCD LSI
1SDA074205R1
E1.2..E6.2
Ekip LCD LSIG
1SDA074206R1
E1.2..E6.2
Ekip G LCD LSIG
1SDA074207R1
E1.2..E6.2
Ekip Hi-LCD LSI
1SDA074208R1
E1.2..E6.2
Ekip Hi-LCD LSIG
1SDA074209R1
E1.2..E6.2
Ekip G Hi-LCD LSIG
1SDA074210R1
E1.2..E6.2
Battery for Ekip trip units
1SDA074193R1
Options for Ekip electrical trip units
9
Size
Type
Code
E1.2..E6.2
Ekip LCD Installed
1SDA074211R1
E1.2..E6.2
Ekip Power Controller
1SDA074212R1
E1.2..E6.2
Upper internal installed voltage outlets
1SDA074216R1
E1.2..E6.2
External installed voltage outlets
1SDA074217R1
E1.2..E6.2
Arrangement for cables with lower internal voltage outlets
1SDA074213R1
E1.2..E6.2
Arrangement for cables with upper internal voltage outlets
1SDA074214R1
E1.2..E6.2
Arrangement for cables with external voltage outlets
1SDA074215R1
1SDC200541F001
1SDC200540F001
1SDC200539F001
Power Supply modules
Size
Type
Code
E1.2..E6.2
Ekip Supply 110-240V AC/DC
1SDA074172R1
E1.2..E6.2
Ekip Supply 24-48V DC
1SDA074173R1
Connectivity modules
Size
Type
Code
E1.2..E6.2
Ekip Com Modbus RS-485
1SDA074150R1
E1.2..E6.2
Ekip Com Modbus TCP
1SDA074151R1
E1.2..E6.2
Ekip Com Profibus
1SDA074152R1
E1.2..E6.2
Ekip Com Profinet
1SDA074153R1
E1.2..E6.2
Ekip Com DeviceNet
1SDA074154R1
E1.2..E6.2
Ekip Com EtherNet/IP
1SDA074155R1
E1.2..E6.2
Ekip Com IEC61850
1SDA074156R1
E1.2..E6.2
Ekip Com R Modbus RS-485
1SDA074157R1
E1.2..E6.2
Ekip Com R Modbus TCP
1SDA074158R1
E1.2..E6.2
Ekip Com R Profibus
1SDA074159R1
E1.2..E6.2
Ekip Com R Profinet
1SDA074160R1
E1.2..E6.2
Ekip Com R DeviceNet
1SDA074161R1
E1.2..E6.2
Ekip Com R EtherNet/IP
1SDA074162R1
E1.2..E6.2
Ekip Link
1SDA074163R1
E1.2..E6.2
Ekip Bluetooth
1SDA074164R1
E1.2..E6.2
Ekip Com GPRS-M
1SDA074165R1
E1.2..E6.2
Ekip Com Actuator
1SDA074166R1
9/62 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 62
15/04/2013 18:01:58
1SDC200544F001
Signalling modules
Size
Type
Code
E1.2..E6.2
Ekip 2K-1
1SDA074167R1
E1.2..E6.2
Ekip 2K-2
1SDA074168R1
E1.2..E6.2
Ekip 2K-3
1SDA074169R1
E2.2..E6.2
Ekip 4K
1SDA074170R1
E1.2..E6.2
Ekip 10K
1SDA074171R1
1SDC200548F001
Measuring and protection modules
Size
Type
Code
E1.2
Ekip Measuring
1SDA074184R1
E1.2
Ekip Measuring Pro
1SDA074185R1
E2.2
Ekip Measuring
1SDA074186R1
E2.2
Ekip Measuring Pro
1SDA074187R1
E4.2
Ekip Measuring
1SDA074188R1
E4.2
Ekip Measuring Pro
1SDA074189R1
E6.2
Ekip Measuring
1SDA074190R1
E6.2
Ekip Measuring Pro
1SDA074191R1
E1.2..E6.2
Ekip Synchrocheck
1SDA074183R1
E2.2..E6.2
Ekip Fan 24V DC
1SDA074174R1
E2.2
Fan module for three-pole circuit-breaker
1SDA074176R1
E2.2
Fan module for four-pole circuit-breaker
1SDA074177R1
E4.2
Fan module for three-pole circuit-breaker
1SDA074178R1
E4.2
Fan module for four-pole circuit-breaker
1SDA074179R1
E6.2
Fan module for three-pole circuit-breaker
1SDA074180R1
E6.2
Fan module for four-pole circuit-breaker
1SDA074181R1
E6.2
Fan module for four-pole circuit-breaker with full size neutral
1SDA074182R1
9
1SDC200559F001
1SDC200558F001
Displaying and supervision systems
Size
Type
Code
E1.2..E6.2
Ekip Multimeter Display on front of switchgear
1SDA074192R1
E1.2..E6.2
Ekip Control Panel for 10 circuit-breakers
1SDA074311R1
E1.2..E6.2
Ekip control panel for 30 circuit-breakers
1SDA074312R1
E1.2..E6.2
Ekip Control Panel license extension to 30 circuit-breakers
1SDA074313R1
E1.2..E6.2
Ekip Control Panel alarm dispatcher option
1SDA074314R1
E1.2..E6.2
Ekip Control Panel option 5 eccess web client
1SDA074315R1
E1.2..E6.2
Ekip View Software for 30 circuit-breakers
1SDA074298R1
E1.2..E6.2
Ekip View software for 60 circuit-breakers
1SDA074299R1
E1.2..E6.2
Ekip View software for unlimited circuit-breakers
1SDA074300R1
E1.2..E6.2
Ekip View license extension to 60 circuit-breakers
1SDA074301R1
E1.2..E6.2
Ekip View license extension for an unlimited number of circuit-breakers
1SDA074302R1
E1.2..E6.2
Ekip View alarm dispatcher option for 30 circuit-breakers
1SDA074303R1
E1.2..E6.2
Ekip View alarm dispatcher option for 60 circuit-breakers
1SDA074304R1
E1.2..E6.2
Ekip View alarm dispatcher option for an unlimited number of circuit-breakers
1SDA074305R1
E1.2..E6.2
Ekip View 5 web access client option license of 30 circuit-breakers
1SDA074306R1
E1.2..E6.2
Ekip View 5 web access client option license of 60 circuit-breakers
1SDA074307R1
E1.2..E6.2
Ekip View 5 web access client option license for an unlimited number of
circuit-breakers
1SDA074308R1
E1.2..E6.2
Ekip View redundancy option
1SDA074309R1
E1.2..E6.2
Ekip View OPC server-client option
1SDA074310R1
ABB Catalogue | 1SDC200023D0201 | 9/63
Emax2_cap09.indd 63
15/04/2013 18:01:59
1SDC200554F001
Accessories
Ekip modules
9
Rating plug for Ekip trip units
Size
Type
Code
(loose supply)
Code
(installed)
E1.2..E6.2
Rating Plug 100A
1SDA074218R1
1SDA074258R1
E1.2..E6.2
Rating Plug 200A
1SDA074219R1
1SDA074259R1
E1.2..E6.2
Rating Plug 250A
1SDA074220R1
1SDA074260R1
E1.2..E6.2
Rating Plug 400A
1SDA074221R1
1SDA074261R1
E1.2..E6.2
Rating Plug 630A
1SDA074222R1
1SDA074262R1
E1.2..E6.2
Rating Plug 800A
1SDA074223R1
1SDA074263R1
E1.2..E6.2
Rating Plug 1000A
1SDA074224R1
1SDA074264R1
E1.2..E6.2
Rating Plug 1250A
1SDA074225R1
1SDA074265R1
E1.2..E6.2
Rating Plug 1600A
1SDA074226R1
1SDA074266R1
E1.2..E6.2
Rating Plug 2000A
1SDA074227R1
1SDA074267R1
E1.2..E6.2
Rating Plug 2500A
1SDA074228R1
1SDA074268R1
E1.2..E6.2
Rating Plug 3200A
1SDA074229R1
1SDA074269R1
E1.2..E6.2
Rating Plug 4000A
1SDA074230R1
1SDA074270R1
E1.2..E6.2
Rating Plug 5000A
1SDA074231R1
1SDA074271R1
E1.2..E6.2
Rating Plug 6300A
1SDA074232R1
1SDA074272R1
E1.2..E6.2
Rating Plug 100A L OFF
1SDA074233R1
1SDA074273R1
E1.2..E6.2
Rating Plug 200A L OFF
1SDA074234R1
1SDA074274R1
E1.2..E6.2
Rating Plug 250A L OFF
1SDA074235R1
1SDA074275R1
E1.2..E6.2
Rating Plug 400A L OFF
1SDA074236R1
1SDA074276R1
E1.2..E6.2
Rating Plug 630A L OFF
1SDA074237R1
1SDA074277R1
E1.2..E6.2
Rating Plug 800A L OFF
1SDA074238R1
1SDA074278R1
E1.2..E6.2
Rating Plug 1000A L OFF
1SDA074239R1
1SDA074279R1
E1.2..E6.2
Rating Plug 1250A L OFF
1SDA074240R1
1SDA074280R1
E1.2..E6.2
Rating Plug 1600A L OFF
1SDA074241R1
1SDA074281R1
E1.2..E6.2
Rating Plug 2000A L OFF
1SDA074242R1
1SDA074282R1
E1.2..E6.2
Rating Plug 2500A L OFF
1SDA074243R1
1SDA074283R1
E1.2..E6.2
Rating Plug 3200A L OFF
1SDA074244R1
1SDA074284R1
E1.2..E6.2
Rating Plug 4000A L OFF
1SDA074245R1
1SDA074285R1
E1.2..E6.2
Rating Plug 5000A L OFF
1SDA074246R1
1SDA074286R1
E1.2..E6.2
Rating Plug 6300A L OFF
1SDA074247R1
1SDA074287R1
E1.2..E6.2
Rating Plug RC 100A
1SDA074248R1
1SDA074288R1
E1.2..E6.2
Rating Plug RC 200A
1SDA074249R1
1SDA074289R1
E1.2..E6.2
Rating Plug RC 250A
1SDA074250R1
1SDA074290R1
E1.2..E6.2
Rating Plug RC 400A
1SDA074251R1
1SDA074291R1
E1.2..E6.2
Rating Plug RC 630A
1SDA074252R1
1SDA074292R1
E1.2..E6.2
Rating Plug RC 800A
1SDA074253R1
1SDA074293R1
E1.2..E6.2
Rating Plug RC 1250A
1SDA074254R1
1SDA074294R1
E1.2..E6.2
Rating Plug RC 2000A
1SDA074255R1
1SDA074295R1
E1.2..E6.2
Rating Plug RC 3200A
1SDA074256R1
1SDA074296R1
E1.2..E6.2
Rating Plug RC 4000A
1SDA074257R1
1SDA074297R1
9/64 | 1SDC200023D0201 | ABB Catalogue
Emax2_cap09.indd 64
15/04/2013 18:02:00
Accessories
Terminals
Kit for terminals - installed for fixed circuit-breaker
Size
Rear orientable terminal - HR VR
Horizontal rear spread terminal - SHR
Vertical rear spread terminal - SVR
Extended front terminal - EF
Front terminal - F
Front spread terminal - ES
Version
Iu max
Type
3 Poles
4 Poles
Code
Code
E1.2
F
1600
Kit EF Upper
1SDA073963R1
1SDA073964R1
E1.2
F
1600
Kit EF Lower
1SDA073965R1
1SDA073966R1
E1.2
F
1600
Kit ES Upper
1SDA073975R1
1SDA073976R1
E1.2
F
1600
Kit ES Lower
1SDA073977R1
1SDA073978R1
E1.2
F
1600
Kit HR Upper
1SDA073981R1
1SDA073982R1
E1.2
F
1600
Kit HR Lower
1SDA073983R1
1SDA073984R1
E1.2
F
1600
Kit VR Upper
1SDA073985R1
1SDA073986R1
E1.2
F
1600
Kit VR Lower
1SDA073987R1
1SDA073988R1
E1.2
F
1600
Kit FC CuAl 4x240 mm2 Upper
1SDA073997R1
1SDA073998R1
E1.2
F
1600
Kit FC CuAl 4x240 mm2 Lower
1SDA073999R1
1SDA074000R1
E2.2
F
2000
Kit VR Upper
1SDA074003R1
1SDA074004R1
E2.2
F
2000
Kit VR Lower
1SDA074005R1
1SDA074006R1
E2.2
F
2500
Kit VR Upper
1SDA074009R1
1SDA074010R1
E2.2
F
2500
Kit VR Lower
1SDA074011R1
1SDA074012R1
E2.2
F
2000
Kit SHR Upper
1SDA074045R1
1SDA074046R1
E2.2
F
2000
Kit SHR Lower
1SDA074047R1
1SDA074048R1
E2.2
F
2500
Kit SHR Upper
1SDA074051R1
1SDA074052R1
E2.2
F
2500
Kit SHR Lower
1SDA074053R1
1SDA074054R1
E2.2
F
2000
Kit SVR Upper
1SDA074057R1
1SDA074058R1
E2.2
F
2000
Kit SVR Lower
1SDA074059R1
1SDA074060R1
E2.2
F
2500
Kit SVR Upper
1SDA074063R1
1SDA074064R1
E2.2
F
2500
Kit SVR Lower
1SDA074065R1
1SDA074066R1
E2.2
F
2500
Kit F Upper
1SDA074118R1
1SDA074119R1
E2.2
F
2500
Kit F Lower
1SDA074120R1
1SDA074121R1
E4.2
F
3200
Kit VR Upper
1SDA074015R1
1SDA074016R1
E4.2
F
3200
Kit VR Lower
1SDA074017R1
1SDA074018R1
E4.2
F
4000
Kit VR Upper
1SDA074021R1
1SDA074022R1
E4.2
F
4000
Kit VR Lower
1SDA074023R1
1SDA074024R1
E4.2
F
4000
Kit F Upper
1SDA074126R1
1SDA074127R1
E4.2
F
4000
Kit F Lower
1SDA074128R1
1SDA074129R1
E6.2
F
5000
Kit VR Upper
1SDA074027R1
1SDA074028R1
E6.2
F
5000
Kit VR Lower
1SDA074030R1
E6.2/f
F
5000
Kit VR Upper
E6.2/f
F
5000
Kit VR Lower
E6.2
F
6300
Kit F Upper
1SDA074134R1
E6.2
F
6300
Kit F Lower
1SDA074137R1
E6.2/f
F
6300
Kit F Upper
1SDA074136R1
E6.2/f
F
6300
Kit F Lower
1SDA074139R1
E6.2
F
6300
Kit VR Upper
1SDA074036R1
E6.2
F
6300
Kit VR Lower
1SDA074039R1
E6.2/f
F
6300
Kit VR Upper
1SDA074038R1
E6.2/f
F
6300
Kit VR Lower
1SDA074041R1
9
1SDA074031R1
1SDA074029R1
1SDA074032R1
1SDA074135R1
1SDA074138R1
1SDA074037R1
1SDA074040R1
Terminal for cable FcCuAl
4x240mm2 - Fc CuAl
ABB Catalogue | 1SDC200023D0201 | 9/65
Emax2_cap09.indd 65
15/04/2013 18:02:01
Accessories
Terminals
Kit for terminals - installed for fixed part of withdrawable circuit-breaker
Size
Rear orientable terminal - HR VR
Horizontal rear terminal - SHR
Vertical rear spread terminal - SVR
9
Front terminal - F
Extended front terminal - EF
Front spread terminal - ES
Terminal for cable FcCuAl
4x240mm2 - Fc CuAl
Version
Iu max
Type
3 Poles
4 Poles
Code
Code
E1.2
W
1600
Kit EF Upper
1SDA073939R1
1SDA073940R1
E1.2
W
1600
Kit EF Lower
1SDA073941R1
1SDA073942R1
E1.2
W
1600
Kit VR Upper
1SDA073945R1
1SDA073946R1
E1.2
W
1600
Kit VR Lower
1SDA073947R1
1SDA073948R1
E1.2
W
1600
Kit ES Upper *
1SDA073951R1
1SDA073952R1
E1.2
W
1600
Kit ES Lower *
1SDA073953R1
1SDA073954R1
E1.2
W
1600
Kit SHR Upper
1SDA073957R1
1SDA073958R1
E1.2
W
1600
Kit SHR Lower
1SDA073959R1
1SDA073960R1
E1.2
W
1600
Kit FC CuAl 4x240 mm2 Upper
1SDA073991R1
1SDA073993R1
E1.2
W
1600
Kit FC CuAl 4x240 mm2 Lower
1SDA073992R1
1SDA073994R1
E2.2
W
2000
Kit VR Upper
1SDA074577R1
1SDA074578R1
E2.2
W
2000
Kit VR Lower
1SDA074579R1
1SDA074580R1
E2.2
W
2500
Kit VR Upper
1SDA074581R1
1SDA074582R1
E2.2
W
2500
Kit VR Lower
1SDA074583R1
1SDA074584R1
E2.2
W
2000
Kit SHR Upper
1SDA074585R1
1SDA074586R1
E2.2
W
2000
Kit SHR Lower
1SDA074587R1
1SDA074588R1
E2.2
W
2500
Kit SHR Upper
1SDA074589R1
1SDA074590R1
E2.2
W
2500
Kit SHR Lower
1SDA074591R1
1SDA074592R1
E2.2
W
2000
Kit SVR Upper
1SDA074593R1
1SDA074594R1
E2.2
W
2000
Kit SVR Lower
1SDA074595R1
1SDA074596R1
E2.2
W
2500
Kit SVR Upper
1SDA074597R1
1SDA074598R1
E2.2
W
2500
Kit SVR Lower
1SDA074599R1
1SDA074600R1
E2.2
W
2500
Kit FL Upper
1SDA074069R1
1SDA074070R1
E2.2
W
2500
Kit FL Lower
1SDA074071R1
1SDA074072R1
E2.2
W
2500
Kit F Upper
1SDA074090R1
1SDA074091R1
E2.2
W
2500
Kit F Lower
1SDA074092R1
1SDA074093R1
E4.2
W
3200
Kit VR Upper
1SDA074601R1
1SDA074602R1
E4.2
W
3200
Kit VR Lower
1SDA074603R1
1SDA074604R1
E4.2
W
4000
Kit VR Upper
1SDA074605R1
1SDA074606R1
E4.2
W
4000
Kit VR Lower
1SDA074607R1
1SDA074608R1
Kit F Upper
1SDA074098R1
1SDA074099R1
E4.2
W
4000
E4.2
W
4000
Kit F Lower
1SDA074100R1
1SDA074101R1
E4.2
W
4000
Kit FL Upper
1SDA074075R1
1SDA074076R1
E4.2
W
4000
Kit FL Lower
1SDA074077R1
1SDA074078R1
E6.2
W
5000
Kit VR Upper
1SDA074609R1
1SDA074610R1
1SDA074612R1
E6.2
W
5000
Kit VR Lower
E6.2/f
W
5000
Kit VR Upper
E6.2/f
W
5000
Kit VR Lower
E6.2
W
6300
Kit VR Upper
1SDA074615R1
1SDA074618R1
E6.2
W
6300
Kit VR Lower
E6.2/f
W
6300
Kit VR Upper
1SDA074614R1
E6.2/f
W
6300
Kit VR Lower
W
6300
Kit F Upper
1SDA074106R1
1SDA074109R1
E6.2
W
6300
Kit F Lower
W
6300
Kit F Upper
1SDA074616R1
1SDA074619R1
1SDA074617R1
E6.2
E6.2/f
1SDA074613R1
1SDA074611R1
1SDA074620R1
1SDA074107R1
1SDA074110R1
1SDA074108R1
E6.2/f
W
6300
Kit F Lower
E6.2
W
6300
Kit FL Upper
1SDA074081R1
1SDA074084R1
1SDA074111R1
1SDA074082R1
E6.2
W
6300
Kit FL Lower
E6.2/f
W
6300
Kit FL Upper
1SDA074083R1
E6.2/f
W
6300
Kit FL Lower
1SDA074086R1
* can be ordered only if the fixed part has EF terminals.
9/66 | 1SDC200023D0201 | ABB Catalogue
1SDA074085R1
Kit for terminals - loose supply for fixed circuit-breaker
Size
Rear orientable terminal - HR VR
Horizontal rear spread terminal - SHR
Vertical rear spread terminal - SVR
Extended front terminal - EF
Version
Iu max
Type
3 Poles
4 Poles
Code
Code
E1.2
F
1600
Kit EF
1SDA073967R1
1SDA073968R1
E1.2
F
1600
Kit F
1SDA073973R1
1SDA073974R1
E1.2
F
1600
Kit ES
1SDA073979R1
1SDA073980R1
E1.2
F
1600
Kit Adjustable HR/VR
1SDA073989R1
1SDA073990R1
E1.2
F
1600
Kit FC CuAl 4x240 mm2
1SDA074001R1
1SDA074002R1
E2.2
F
2000
Kit Adjustable HR/VR
1SDA074007R1
1SDA074008R1
E2.2
F
2500
Kit Adjustable HR/VR
1SDA074013R1
1SDA074014R1
E2.2
F
2000
Kit SHR
1SDA074049R1
1SDA074050R1
E2.2
F
2500
Kit SHR
1SDA074055R1
1SDA074056R1
E2.2
F
2000
Kit SVR
1SDA074061R1
1SDA074062R1
E2.2
F
2500
Kit SVR
1SDA074067R1
1SDA074068R1
E4.2
F
3200
Kit Adjustable HR/VR
1SDA074019R1
1SDA074020R1
E4.2
F
4000
Kit Adjustable HR/VR
1SDA074025R1
1SDA074026R1
E4.2
F
4000
Kit F Upper
1SDA074130R1
1SDA074131R1
E4.2
F
4000
Kit F Lower
1SDA074132R1
1SDA074133R1
E6.2
F
5000
Kit Adjustable HR/VR
1SDA074033R1
1SDA074034R1
E6.2/f
F
5000
Kit Adjustable HR/VR
E6.2
F
6300
Kit Adjustable HR/VR
E6.2/f
F
6300
Kit Adjustable HR/VR
E6.2
F
6300
Kit F Upper
1SDA074140R1
1SDA074141R1
E6.2
F
6300
Kit F Lower
1SDA074143R1
1SDA074144R1
E6.2/f
F
6300
Kit F Upper
1SDA074142R1
E6.2/f
F
6300
Kit F Lower
1SDA074145R1
1SDA074035R1
1SDA074042R1
1SDA074043R1
1SDA074044R1
9
Adapter plate for terminals - loose supply for fixed circuit-breaker
Size
Version
Iu
Type
3 Poles
4 Poles
Code
Code
E2.2
F
2500
Kit Terminal Adapter Plate
1SDA074146R1
1SDA074147R1
E4.2
F
4000
Kit Terminal Adapter Plate
1SDA074148R1
1SDA074149R1
Front terminal - F
Front spread terminal - ES
Terminal for cable FcCuAl
4x240mm2 - Fc CuAl
ABB Catalogue | 1SDC200023D0201 | 9/67
Emax2_cap09.indd 67
15/04/2013 18:02:05
Accessories
Terminals
Kit for terminals - loose supply for fixed part of withdrawable circuit-breaker
Size
Rear orientable terminal - HR VR
Horizontal rear terminal - SHR
Vertical rear spread terminal - SVR
9
Front terminal - F
Version
Iu max
Type
3 Poles
4 Poles
Code
Code
E1.2
W
1600
Kit EF
1SDA073943R1
1SDA073944R1
E1.2
W
1600
Kit Adjustable HR/VR
1SDA073949R1
1SDA073950R1
E1.2
W
1600
Kit ES
1SDA073955R1
1SDA073956R1
E1.2
W
1600
Kit SHR
1SDA073961R1
1SDA073962R1
E1.2
W
1600
Kit FC CuAl 4x240 mm2
1SDA073995R1
1SDA073996R1
E2.2
W
2000
Kit Adjustable HR/VR
1SDA074007R1
1SDA074008R1
E2.2
W
2500
Kit Adjustable HR/VR
1SDA074013R1
1SDA074014R1
E2.2
W
2000
Kit SHR
1SDA074049R1
1SDA074050R1
E2.2
W
2500
Kit SHR
1SDA074055R1
1SDA074056R1
E2.2
W
2000
Kit SVR
1SDA074061R1
1SDA074062R1
E2.2
W
2500
Kit SVR
1SDA074067R1
1SDA074068R1
E2.2
W
2500
Kit FL
1SDA074073R1
1SDA074074R1
Kit Adjustable HR/VR
1SDA074019R1
1SDA074020R1
E4.2
W
3200
E4.2
W
4000
Kit Adjustable HR/VR
1SDA074025R1
1SDA074026R1
E4.2
W
4000
Kit F Upper
1SDA074102R1
1SDA074103R1
E4.2
W
4000
Kit F Lower
1SDA074104R1
1SDA074105R1
E4.2
W
4000
Kit FL
1SDA074079R1
1SDA074080R1
1SDA074033R1
E6.2
W
5000
Kit Adjustable HR/VR
E6.2/f
W
5000
Kit Adjustable HR/VR
E6.2
W
6300
Kit Adjustable HR/VR
E6.2/f
W
6300
Kit Adjustable HR/VR
1SDA074042R1
E6.2
W
6300
Kit F Upper
1SDA074112R1
W
6300
Kit F Lower
1SDA074115R1
E6.2/f
W
6300
Kit F Upper
E6.2/f
W
6300
Kit F Lower
E6.2
W
6300
Kit FL
E6.2/f
W
6300
Kit FL
Front spread terminal - ES
Terminal for cable FcCuAl
4x240mm2 - Fc CuAl
9/68 | 1SDC200023D0201 | ABB Catalogue
1SDA074043R1
1SDA074044R1
E6.2
Extended front terminal - EF
1SDA074034R1
1SDA074035R1
1SDA074113R1
1SDA074116R1
1SDA074114R1
1SDA074117R1
1SDA074087R1
1SDA074088R1
1SDA074089R1
www.abb.com
The data and illustrations are not binding. We reserve
the right to modify the contents of this document on the
basis of technical development of the products, without
prior notice.
Copyright 2013 ABB. All rights reserved.
1SDC200023D0201 - 03/2013 - 6.000 - CAL - Preliminary
ABB SACE
A division of ABB S.p.A.
L.V. Breakers
Via Baioni, 35
24123 Bergamo
Phone: +39 035 395.111
Fax: +39 035 395.306-433
SACE Emax 2. New low voltage air circuit-breakers
Contact us
Technical catalogue - Edition 03.2013 - Preliminary
Technical cat. | Ed. 03.2013 | Preliminary
SACE Emax 2
New low voltage air circuit-breakers