www.abb.com The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2013 ABB. All rights reserved. 1SDC200023D0201 - 03/2013 - 6.000 - CAL - Preliminary ABB SACE A division of ABB S.p.A. L.V. Breakers Via Baioni, 35 24123 Bergamo Phone: +39 035 395.111 Fax: +39 035 395.306-433 SACE Emax 2. New low voltage air circuit-breakers Contact us Technical catalogue - Edition 03.2013 - Preliminary Technical cat. | Ed. 03.2013 | Preliminary SACE Emax 2 New low voltage air circuit-breakers Index Main characteristics 1 The ranges 2 Protection trip units 3 Communication devices and systems 4 Accessories 5 Installation 6 Overall dimensions 7 Wiring diagrams 8 Ordering codes 9 ABB catalogue | 1SDC200023D0201 | 0/1 Emax2_cap01.indd 1 12/04/2013 13:52:56 SACE Emax 2 Consultation guide Chapter 1 Main characteristics Overview of the SACE Emax 2 family, distinctive features of the series, product conformity and service. Chapter 5 Accessories Accessories for SACE Emax 2 circuitbreakers (signaling, control, interlocks, etc..) and for Ekip protection trip units (connectivity, measurements, protection, etc). Chapter 2 The ranges Electrical characteristics of automatic circuit-breakers, switch-disconnectors and derived versions. Chapter 6 Installation Installation and circuit-breaker performance in switchgear, installation environment, degree of protection and limiting curves. Chapter 3 Protection trip units Latest generation Ekip protection trip units for power distribution, generator protection and power control. Chapter 7 Overall dimensions Overall dimensions for fixed circuitbreakers, withdrawable circuit-breakers and accessories. Chapter 4 Communication devices and systems Supervision, Energy Management and complete integration in the systems with the possibility of communicating with all the main protocols used in the industrial sector. Chapter 8 Wiring diagrams Circuit-breaker and accessories wiring diagrams. 00000 000 00 Chapter 9 Ordering codes Ordering codes with configuration examples. 0/2 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 2 12/04/2013 13:52:57 Main characteristics Overview of the SACE Emax 2 family Guide to selection 1/2 1 Distinctive features of the series Efficiency 1/3 Control 1/4 Connectivity 1/5 Performance 1/6 Ease of use and safety 1/7 Product conformity Approvals and certifications 1/9 Quality and Sustainability 1/10 ABB SACE Global Service 1/12 ABB catalogue | 1SDC200023D0201 | 1/1 Emax2_cap01.indd 1 12/04/2013 13:52:57 Overview of the SACE Emax 2 family 1 Guide to selection Ranges available E1.2 E2.2 E4.2 E6.2 Automatic circuit-breakers @ 690-1150 V AC • • • • Switch-disconnectors @ 690-1150 V AC, 1000 V DC • Sectionalizing truck • • • • • • Earthing switch with making capacity • • • Earthing truck • • • Automatic circuit-breakers Icu (440Vac) Versione 200 X 150 V 100 H 85 S 66 N 50 C 42 B 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 E6.2 E4.2 E2.2 E1.2 Switch-disconnectors Icw (1s) Version 120 X 100 V 85 H 66 N 50 N 42 B 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 E6.2 E4.2 E2.2 E1.2 Protection trip units Version Ekip Dip Ekip Touch Ekip Hi-Touch Application Distribution Power control Generators Protection devices - - Protection devices and Measurements Protection devices and Measurements - Protection devices, Measurements, Network analyzer Protection devices, Measurements, Network analyzer - Protection devices and Measurements Protection devices and Measurements Protection devices, Measurements, Network analyzer Protection devices, Measurements, Network analyzer Ekip G Touch Ekip G Hi-Touch 1/2 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 2 12/04/2013 13:52:57 Distinctive features SACE Emax 2 is a new series of low voltage air circuit-breakers up to 6300 A. With the ability to efficiently and simply control electrical installations – from the traditional to the more complex – with minimum impact, the new SACE Emax 2 circuit-breakers represent the evolution of a circuit-breaker into a Power Manager. 1 Efficiency 1SDC200403F001 1SDC200402F001 SACE Emax 2 air circuit-breakers have been designed to manage, with maximum efficiency, all low voltage electrical installations: from industrial plants, naval applications, traditional and renewable power generation installations to buildings, shopping centres, data centres and communication networks. Achieving maximum efficiency of an electrical installation in order to reduce consumption and waste requires intelligent management of power supplies and energy use. For this reason, the new technologies used in the SACE Emax 2 circuitbreakers allow the productivity and reliability of installations to be optimized, and at the same time, power consumption to be reduced while fully respecting the environment. ABB catalogue | 1SDC200023D0201 | 1/3 Emax2_cap01.indd 3 12/04/2013 13:52:58 Distinctive features Control The exclusive Power Controller function available on the new SACE Emax 2 circuit-breakers monitors the power managed by the circuit-breaker, keeping it below the limit set by the user. As a result of this more effective use, the peak of power consumed can be limited allowing savings on electricity bills. The Power Controller, patented by ABB, disconnects non-priority utilities, such as electric car charging stations, lighting or refrigeration units, during the times when consumption limits need to be respected, and connects them again as soon as it is appropriate. When required, it automatically activates auxiliary power supplies such as generator sets. No monitoring system is required: it is sufficient to set the required load limit on Emax 2, which can control any circuit-breaker located downstream, even if it is not equipped with a measurement function. In installations that are already equipped with energy management systems, the load limit can also be modified remotely. SACE Emax 2 circuit-breakers are equipped with a new generation of protection trip units that are easy to programme and read. The Ekip Touch trip units measure power and energy with precision and save the most recent alarms, events and measurements in order to prevent faults to the installation or trip effectively when necessary. On request, the Network Analyzer function is also available, which controls the quality of absorbed power in real time and with extreme precision. In addition, the innovative Ekip Touch and Hi Touch trip units in the G version include all the functions of generator protection switchgear, offering a safe control solution that is ready to use. No external devices, wiring or inspections are required. 1SDC200405F001 1 1/4 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 4 12/04/2013 13:52:59 Connectivity 1 1SDC200406F001 SACE Emax 2 series circuit-breakers can be integrated perfectly into all automation and energy management systems to improve productivity and energy consumption and to carry out remote service. All circuit-breakers can be equipped with communication units available for use with Modbus, Profibus, and DeviceNet protocols as well as the modern Modbus TCP, Profinet and EtherNet IP protocols. The cartridge-type modules can be easily installed directly on the terminal box, even at a later date. Furthermore, the integrated IEC61850 communication module enables connection to automation systems widely used in medium voltage power distribution to create intelligent networks (Smart Grids). Accurate measurements of current, voltage, power and energy are all available by means of the communication modules. The trip units themselves can be used as multimeters that display the measurements available, or the Ekip Multimeter can be connected in the front of the switchgear without the need for external instruments and bulky transformers. All circuit-breaker functions are also accessible via the Internet, in complete safety, through the Ekip Link switchgear supervision system and the Ekip Control Panel operator panel. The power and auxiliary connections are optimized to simplify connection to the switchgear. The power terminals, which can be oriented horizontally or vertically, have been designed for the most common busbars, while the push-in connections of the auxiliaries ensure immediate and safe wiring. ABB catalogue | 1SDC200023D0201 | 1/5 Emax2_cap01.indd 5 12/04/2013 13:53:00 Distinctive features 1 Performance The SACE Emax 2 range is made up of 4 sizes: E1.2, E2.2, E4.2 and E6.2 up to 6300A, which enable switchgear of compact dimensions and high ratings to be built with busbars of reduced length and cross-section. The protection trip units, auxiliary connections and main accessories are the same throughout the range to simplify design and installation. Furthermore, the sizes from E2.2 to E6.2 have the same height and depth. The rating levels are updated and uniform throughout the sizes to meet the demands and needs of today’s installations, from 42kA to 200kA, and to standardize switchgear projects. High short-time currents, together with the efficiency of the protection functions, guarantee complete selectivity in all situations. Accurate design and choice of materials enable optimization of the overall dimensions of the circuit-breaker. In this way switchgear of compact dimensions can be built and outstanding savings at the same performance can be obtained. In particular: – E1.2 offers 1,600A with breaking capacity up to 66kA and withstand current of 50kA for 1 second in an extremely compact structure. In the three and four pole version, it offers the sturdiness of SACE Emax with reduced dimensions and enables switchgear of 66kA to be built in units of 400mm, which is indispensable in places where reduced dimensions are essential, such as naval and offshore installations. – E2.2 enables in the three pole version ratings of up to 2,500A to be achieved in switchgear with a width of 400mm. In addition, it provides short-circuit currents up to 100kA and 85kA for 1 second. – E4.2 is the new 4,000A circuit-breaker designed to withstand high currents with a withstand rating of 100kA for 1 second without the need for particular precautions. – E6.2 is the top of the range, with an interrupting rating of 200kA and a structure that allows 6,300A to be reached, even in complex installation conditions. 1/6 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 6 12/04/2013 13:53:01 Ease of use and safety 1 The entire range is available in fixed and withdrawable versions, with double insulation between the front of the switchgear and the live parts to ensure operation in complete safety. The circuit-breakers can be powered indifferently from above or below. All essential information is available in the central area of the front shield and enables immediate identification of the status of the circuit-breaker: open, closed, ready to close, charged and discharged springs. Maintenance is simply and safe. Thanks to the new front shield, the main accessories can be frontally accessed without completely removing it. The withdrawable circuit-breaker is inserted and removed via dedicated guide rails that simplify movement. The correct movement from racked-in, test isolated, to racked-out position is guaranteed by a lock in each position. As a further guarantee of safety, the shutters of the fixed part can be locked from the front when the circuit-breaker is removed. The shutters of the upper terminals are independent of those of the lower terminals to facilitate checking and maintenance operations. The Ekip Touch protection trip units are equipped with a large colour touch-screen display which enables safe and intuitive operation. Furthermore the Ekip units can be programmed and consulted from a tablet, smart phone or portable PC via the Ekip Connect application, which allows the parameters of the safety devices calculated in the DOC software to be set automatically. 1SDC200407F001 The trip units are easily interchangeable from the front of the circuit-breaker, and all communication units can be installed directly on the terminal box with a few simple operations. ABB catalogue | 1SDC200023D0201 | 1/7 Emax2_cap01.indd 7 12/04/2013 13:53:01 Distinctive features 1 2 1 3 4 9 5 7 8 10 1SDC200402F001 6 Key 1 Trademark and size of circuit- breaker 2 SACE Ekip protection trip unit 3 Pushbutton for manual opening 4 Pushbutton for manual closing 5 Lever to manually charge closing springs 6 Electrical rating plate 7 Mechanical device to signal circuit-breaker open “O” and closed “I” 8 Signal for springs charged or discharged 9 Mechanical signalling of overcurrent release tripped 10 Size and serial number 1/8 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 8 12/04/2013 13:53:02 Product conformity SACE Emax 2 circuit-breakers and their accessories conform to IEC 60947, EN 60947 international Standard 1 Approvals and certifications SACE Emax 2 circuit-breakers and their accessories conform to the international IEC 60947, EN 60947 (harmonized in 30 CENELEC countries), CEI EN 60947 and IEC 61000 Standards and comply with the following EC directives: – “Low Voltage Directives” (LVD) no. 2006/95/EC – “Electromagnetic Compatibility Directive” (EMC) no. 2004/108/EC. The ABB air circuit-breakers include a range that has been certified according to American UL 1066 Standards; it is also certified by the Russian certification body GOST (Russia Certificate of Conformity) and has achieved China CCC Certification (China Compulsory Certification). Certification of conformity with the above-mentioned product Standards is carried out in compliance with the European EN 45011 Standard by the Italian certification body ACAE (Association for the Certification of Electrical Equipment),which is recognized by the European organization LOVAG (Low Voltage Agreement Group), and by the Swedish Intertek SEMKO certification organization Intertek Semko which is recognized by the international organization IECEE. Germanischer Lloyd (GL): Deutsch Lloyd’s Register of Shipping (LR): English Bureau Veritas (BV): French Nippon Kaiji Kyokai (NKK): Japan 1SDC200415F001 1SDC200412F001 American Bureau Shipping (ABS): American Russian Maritime Register of Shipping (RMRS): Russian Det Norske Veritas (DNV): Norway 1SDC200413F001 1SDC200410F001 1SDC200409F001 1SDC200411F001 1SDC200408F001 Registro Italiano Navale (RINA): Italian 1SDC200414F001 The main versions of the devices are about to be approved by the following shipping registers For the types of certified circuit-breakers, certified ratings and corresponding validity, please contact ABB SACE. ABB catalogue | 1SDC200023D0201 | 1/9 Emax2_cap01.indd 9 12/04/2013 13:53:04 Product conformity 1 Quality and Sustainability: company efficiency and integrated management systems. Quality, Sustainability and Customer Satisfaction have always been ABB SACE’s major commitment. 1SDC200419F001 1SDC200418F001 1SDC200417F001 1SDC200416F001 The involvement of all company departments and organization of processes have led the company to develop, implement and certify management systems in compliance with international Standards: – ISO 9001 for quality management – IRIS for the quality of supplies in the railway sector (International Railway Industry Standards) – ISO 14001 for environmental management – OHSAS 18001 for the management of the health and safety of employees in the workplace – SA 8000 for the management of social responsibility. 1/10 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 10 12/04/2013 13:53:05 The ABB SACE testing laboratory, accredited by ACCREDIA in compliance with ISO/IEC 17025 Standard, provides both ABB and external customers with a qualified service for performing certification tests on devices and electric equipment of low and medium voltage in accordance with the relevant product Standards. 1 Thanks to the implementation of systems and their integration (Integrated Management System), ABB SACE, with a view to continuous improvement, has implemented processes with a focus on: – quality, preventing defects and faults along the entire supply chain – environment, reviewing production processes in terms of ecology and waste reduction, rationalizing the consumption of raw materials and energy, preventing pollution, containing noise emissions and reducing the quantity of rejects in the production processes – health and safety of employees, offering a healthy and safe workplace in all of the various stages of work with a “zero accident objective” – social responsibility, guaranteeing the respect of human rights and the absence of any discrimination throughout the supply chain, and offering a favourable and transparent working atmosphere. 1SDC200421F001 1SDC200420F001 A further commitment aimed at safeguarding the environment has been achieved by assessing products’ life cycles (LCA, Life Cycle Assessment): this includes the assessment and improvement of the environmental performance of products from the engineering stage throughout their entire life cycle. The materials, processes and packaging used are chosen with a view to optimising the actual environmental impact of each product, including its energy efficiency and recyclability. ABB catalogue | 1SDC200023D0201 | 1/11 Emax2_cap01.indd 11 12/04/2013 13:53:11 ABB SACE Global Service 1 ABB’s technical assistance service offers solutions aimed at supporting the customer in all stages of the lifespan of the circuit-breaker in service and covering the entire chain of value; ABB is present from the moment of selection to the end of the life of the product, thereby guaranteeing the investments of its customers. ABB supplies annual updates regarding the evolution of the circuit-breaker ranges (Life Cycle Management) and for each product it provides details of associated services and the level of support available, so that customers can chose the products and spare parts best suited to their needs. ABB’s organisation offers services that include installation and commissioning, technical training on the use and maintenance of products, the supply of original spare parts, corrective and preventive maintenance, equipment diagnostics, modernisation of systems with upgrades and retrofitting kits, consultancy services and personalised maintenance and service contracts. All this is supported by one of the most extensive global sales and service networks. 1SDC200423F001 1SDC200422F001 Retrofitting kit Through continuous research targeted at the needs of the customer, ABB SACE Service has developed innovative retrofitting kits in order to simplify and speed up installation of a new circuit-breaker, updating the customer’s investment with the latest technology available and with very limited down times. The retrofitting kit between Emax2 and Emax is a retrofill solution: it is therefore possible to replace the withdrawable version of Emax with an equivalent Emax2 model without changing the switchboard busbars, by simply removing the fixed part of Emax replacing it with a fixed part of Emax2 which has been suitably modified with dedicated terminals. 1/12 | 1SDC200023D0201 | ABB catalogue Emax2_cap01.indd 12 12/04/2013 13:53:12 The Ranges SACE Emax 2 automatic circuit-breakers 2/2 SACE Emax 2 switch-disconnectors 2/4 2 SACE Emax 2 automatic circuit-breakers for applications up to 1150V AC 2/6 SACE Emax 2 switch-disconnectors for applications up to 1150V AC 2/8 SACE Emax 2 switch-disconnectors for applications up to 1000 V DC 2/10 SACE Emax 2 derived versions 2/12 ABB catalogue | 1SDC200023D0201 | 2/1 Emax2_cap02.indd 1 15/04/2013 16:21:42 SACE Emax 2 automatic circuit-breakers 2 Rated service voltage Ue [V] 690 Rated insulation voltage Ui [V] 1000 Rated impulse withstand voltage Uimp [kV] 12 Frequency [Hz] 50 - 60 Number of poles 3- 4 Version Fixed - Withdrawable Isolation behaviour IEC 60947-2 1SDC200424F001 Common data SACE Emax 2 E1.2 Performance levels Rated uninterrupted current Iu @ 40°C B C N L [A] 630 630 250 630 [A] 800 800 630 800 [A] 1000 1000 800 1000 [A] 1250 1250 1000 1250 [A] 1600 1600 [A] 1250 1600 [A] Neutral pole current-carrying capacity for 4-pole CBs [%Iu] 100 100 100 100 Rated ultimate short-circuit breaking capacity Icu 400-415 V [kA] 42 50 66 150 440 V [kA] 42 50 66 130 500-525 V [kA] 42 42 50 100 690 V [kA] 42 42 50 60 Rated service short-circuit breaking capacity Ics [%Icu] 100 100 100 Rated short-time withstand current Icw (1s) [kA] 42 42 50 15 (3s) [kA] 24 24 36 - Rated short-circuit making capacity (peak value) Icm 400-415 V [kA] 88 105 145 330 440 V [kA] 88 105 145 286 500-525 V [kA] 88 88 105 220 690 V [kA] 132 1) 100 88 88 105 Utilization category (according to IEC 60947-2) B B B A Breaking 40 40 40 40 Breaking time for I<Icw Breaking time for I>Icw Dimensions 25 25 25 10 H - Fixed/Withdrawable [mm] 296/363.5 296/363.5 296/363.5 296/363.5 D - Fixed/Withdrawable [mm] 183/271 183/271 183/271 183/271 W - Fixed 3p/4p/4p FS [mm] 210/280 W - Withdrawable 3p/4p/4p FS [mm] 278/348 1) Ics : 50kA for 400V…440V voltage SACE Emax 2 E1.2 [Iu] d 1000 1250 1600 1600 L [No.oper.x 1000] 20 20 20 20 Frequency [Oper./Hour] 60 60 60 60 440 V [No.oper.x 1000] 8 8 8 3 690 V [No.oper.x 1000] 8 6,5 6,5 1 Frequency [Oper./Hour] 30 30 30 30 Mechanical and electrical life with regular ordinary maintenance prescribed by the manufacturer Electrical life 2/2 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 2 15/04/2013 16:21:43 E2.2 1SDC200427F001 1SDC200425F001 1SDC200426F001 2 E4.2 E6.2 B N S H N S H V H V X 1600 800 250 800 3200 3200 3200 2000 4000 4000 4000 2000 1000 800 1000 4000 4000 4000 2500 5000 5000 5000 1250 1000 1250 3200 6300 6300 6300 1600 1250 1600 4000 2000 1600 2000 2500 2000 2500 2500 100 100 100 100 100 100 100 100 50-100 50-100 50-100 42 66 85 100 66 85 100 150 100 150 200 42 66 85 100 66 85 100 150 100 150 200 42 66 66 85 66 66 85 100 100 130 130 42 66 66 85 66 66 85 100 100 100 120 100 100 100 100 100 100 100 85 100 100 100 42 66 66 85 66 66 85 100 100 100 120 42 50 50 66 36 50 66 75 100 100 100 88 145 187 220 145 187 220 330 220 330 440 88 145 187 220 145 187 220 330 220 330 440 88 145 145 187 145 145 187 220 220 286 286 88 145 145 187 145 145 187 220 220 220 264 B B B B B B B B B B B 40 40 40 40 40 40 40 40 40 40 40 25 25 25 25 25 25 25 25 25 25 25 371/425 371/425 371/425 371/425 371/425 371/425 371/425 371/425 371/425 371/425 371/425 270/383 270/383 270/383 270/383 270/383 270/383 270/383 270/383 270/383 270/383 270/383 276/366 384/510 762/888/1014 317/407 425/551 803/929/1069 E2.2 E4.2 E6.2 < 1600 1600 2000 2500 < 2500 2500 3200 4000 4000 5000 6300 25 25 25 20 20 20 20 15 12 12 12 60 60 60 60 60 60 60 60 60 60 60 15 12 10 8 10 8 7 5 4 3 2 15 10 8 7 10 8 7 4 4 2 2 30 30 30 30 20 20 20 20 10 10 10 ABB catalogue | 1SDC200023D0201 | 2/3 Emax2_cap02.indd 3 15/04/2013 16:21:47 SACE Emax 2 switch-disconnectors 2 Switch-disconnectors, identified with the abbreviation “/MS”, are devices that satisfy the isolating specifications provided by the IEC 60947-3 Standard. The switch-disconnectors are derived from the corresponding automatic circuit-breakers, and they have the same dimensions and accessory options. This version differs from the automatic circuit-breakers only because of the absence of protection trip units. Common data Rated service voltage Ue [V] 690 Rated insulation voltage Ui [V] 1000 Rated impulse withstand voltage Uimp [kV] 12 Frequency [Hz] 50 - 60 3- 4 Version Fixed - Withdrawable Isolation behaviour IEC 60947-3 1SDC200428F001 Number of poles SACE Emax 2 E1.2 Performance levels B/MS Rated uninterrupted current Iu @ 40°C N/MS [A] 630 250 [A] 800 630 [A] 1000 800 [A] 1250 1000 [A] 1600 1250 [A] 1600 Neutral pole current-carrying capacity for 4-pole CBs [%Iu] 100 100 Rated short-time withstand current Icw (1s) [kA] 42 50 (3s) [kA] 24 36 Rated short-circuit making capacity (peak value) Icm 400-415 V [kA] 88 105 440 V [kA] 88 105 500-525 V [kA] 88 105 690 V [kA] 88 105 AC-23A AC-23A Utilization category (according to IEC 60947-3) Dimensions H - Fixed / Withdrawable [mm] 296 / 363.5 296 / 363.5 D - Fixed / Withdrawable [mm] 183 / 271 183 / 271 W - Fixed 3p/4p/4p FS [mm] 210 / 280 W - Withdrawable 3p/4p/4p FS 278 / 348 SACE Emax 2 E1.2 Mechanical and electrical life with regular ordinary maintenance prescribed by the manufacturer [Iu] < 1000 1000 1600 [No.oper.x 1000] 20 20 20 [Oper./Hour] 60 60 60 440 V [No.oper.x 1000] 8 8 8 690 V [No.oper.x 1000] 8 6.5 6.5 Frequency [Oper./Hour] 30 30 30 Frequency Electrical life 2/4 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 4 15/04/2013 16:21:47 E2.2 E4.2 E6.2 B/MS N/MS H/MS N/MS H/MS V/MS H/MS 1600 800 800 3200 3200 2000 4000 4000 2000 1000 1000 4000 4000 2500 5000 5000 1250 1250 3200 6300 6300 1600 1600 4000 2000 2000 X/MS 2500 2500 100 100 100 100 100 100 50-100 50-100 42 66 85 66 85 100 100 120 42 50 66 36 66 75 100 100 88 145 187 145 187 220 220 264 88 145 187 145 187 220 220 264 88 145 187 145 187 220 220 264 88 145 187 145 187 220 220 264 AC-23A AC-23A AC-23A AC-23A AC-23A AC-23A AC-23A AC-23A 371 / 425 371 / 425 371 / 425 371 / 425 371 / 425 371 / 425 371 / 425 371 / 425 270 / 383 270 / 383 270 / 383 270 / 383 270 / 383 270 / 383 270 / 383 270 / 383 276 / 366 384 / 510 762 / 888 / 1014 317 / 407 425 / 551 803 / 929 / 1069 E2.2 2 1SDC200431F001 1SDC200429F001 1SDC200430F001 The device, when in the open position, guarantees an isolating distance between the main contacts of the circuit-breaker that is sufficient to ensure that the installation downstream is not live. Furthermore the switch-disconnectors, if used with an external protection relay with maximum delay of 500ms, enable a breaking capacity at a maximum rated operating voltage (Ue) equal to the value of rated short-time withstand current (Icw) for one second. E4.2 E6.2 < 1600 1600 2000 2500 < 2500 2500 3200 4000 4000 5000 6300 25 25 25 20 20 20 20 15 12 12 12 60 60 60 60 60 60 60 60 60 60 60 15 12 10 8 10 8 7 5 4 3 2 15 10 8 7 10 8 7 4 4 2 2 30 30 30 30 20 20 20 20 10 10 10 ABB catalogue | 1SDC200023D0201 | 2/5 Emax2_cap02.indd 5 15/04/2013 16:21:49 SACE Emax 2 automatic circuit-breakers for applications up to 1150V AC ABB SACE offers a solution designed for electrical applications with voltages up to 1150V in alternating current. The 1150V AC range, which maintains the same dimensions and accessories as the standard 690V AC range, is identified by the letters “/E”. 2 Rated service voltage Ue [V] 1150 Rated insulation voltage Ui [V] 1250 Rated impulse withstand voltage Uimp [kV] 12 Frequency [Hz] 50 - 60 Number of poles 3- 4 Version Fixed - Withdrawable Isolation behaviour IEC 60947-2 1SDC200424F001 Common data SACE Emax 2 E1.2 Performance levels N/E Rated uninterrupted current Iu @ 40°C [A] 630 [A] 800 [A] 1000 [A] 1250 [A] 1600 [A] Neutral pole current-carrying capacity for 4-pole CBs [%Iu] 100 Rated ultimate short-circuit breaking capacity Icu 1000 V [kA] 30 1150 V [kA] 25 Rated service short-circuit breaking capacity Ics [%Icu] 100 Rated short-time withstand current Icw (1s) [kA] 25 (3s) [kA] 25 1000 V [kA] 63 1150 Z [kA] Rated short-circuit making capacity (peak value) Icm Utilization category (according to IEC 60947-3) SACE Emax 2 E1.2 Mechanical and electrical life with regular ordinary maintenance prescribed by the manufacturer Electrical life 53 B [Iu] < 1000 1000 [No.oper.x 1000] 20 20 1600 20 Frequency [Oper./Hour] 60 60 60 1150 V [No.oper.x 1000] 1 1 1 Frequency [Oper./Hour] 30 30 30 2/6 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 6 15/04/2013 16:21:49 1SDC200427F001 1SDC200425F001 1SDC200426F001 2 E2.2 E4.2 E6.2 H/E H/E X/E 800 3200 4000 1000 4000 5000 1250 6300 1600 2000 2500 100 100 50 - 100 30 50 65 30 30 65 100 100 100 30 50 65 30 30 65 63 105 143 53 105 143 B B B E2.2 E4.2 E6.2 < 2000 2000 2500 < 3200 3200 4000 4000 5000 6300 25 25 20 20 20 15 12 12 12 60 60 60 60 60 60 60 60 60 2 2 2 1 1 1 1 1 1 30 30 30 20 20 20 10 10 10 ABB catalogue | 1SDC200023D0201 | 2/7 Emax2_cap02.indd 7 15/04/2013 16:21:52 SACE Emax 2 switch-disconnectors for applications up to 1150V AC 2 The switch-disconnectors for applications at 1150V, identified by the letters “/E” and “/MS”, are derived from the corresponding standard automatic circuit-breakers, of which maintain the overall dimensions and the possibility of mounting accessories. The switch-disconnectors are not equipped with Ekip protection trip units. By means of external protection relay with 500 ms maximum timing, the Icu breaking capacity is equal to the value of Icw (1s). Rated service voltage Ue [V] 1150 Rated insulation voltage Ui [V] 1250 Rated impulse withstand voltage Uimp [kV] 12 Frequency [Hz] 50 - 60 Number of poles 3- 4 Version Fixed - Withdrawable Isolation behaviour IEC 60947-3 1SDC200428F001 Common data SACE Emax 2 E1.2 Performance levels N/E MS Rated uninterrupted current Iu @ 40°C [A] 630 [A] 800 [A] 1000 [A] 1250 [A] 1600 [A] Neutral pole current-carrying capacity for 4-pole CBs Rated short-time withstand current Icw Rated short-circuit making capacity (peak value) Icm [%Iu] 100 (1s) [kA] 25 (3s) [kA] 25 1000 V [kA] 53 1150 V [kA] 53 SACE Emax 2 E1.2 Mechanical and electrical life with regular ordinary maintenance prescribed by the manufacturer Electrical life [Iu] < 1000 1000 1600 [No.oper.x 1000] 20 20 20 Frequency [Oper./Hour] 60 60 60 1150 V [No.oper.x 1000] 1 1 1 Frequency [Oper./Hour] 30 30 30 2/8 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 8 15/04/2013 16:21:53 1SDC200431F001 1SDC200429F001 1SDC200430F001 2 E2.2 E4.2 E6.2 H/E MS H/E MS X/E MS 800 3200 4000 1000 4000 5000 1250 6300 1600 2000 2500 100 100 50 - 100 30 50 65 30 30 65 53 105 143 53 105 143 E2.2 E4.2 E6.2 < 2000 2000 2500 < 3200 3200 4000 4000 5000 6300 25 25 20 20 20 15 12 12 12 60 60 60 60 60 60 60 60 60 2 2 2 1 1 1 1 1 1 30 30 30 20 20 20 10 10 10 ABB catalogue | 1SDC200023D0201 | 2/9 Emax2_cap02.indd 9 15/04/2013 16:21:54 SACE Emax 2 Switch-disconnectors for applications up to 1000V DC 2 ABB SACE extends its solutions to applications in direct current with a range of switch-disconnectors for applications up to 1000V, which comply with the international IEC60947-3 standard. For all applications in which integrated protection is requested in addition to isolation, ABB SACE offers SACE Emax automatic circuit-breakers with PR122/DC and PR123/DC. For further information, please refer to the technical catalogue “SACE Emax DC. Low voltage air circuit-breakers for direct current applications”. Rated service voltage Ue [V] 750 (3p) / 1000 (4p) Rated insulation voltage Ui [V] 1000 Rated impulse withstand voltage Uimp [kV] 12 Number of poles 3- 4 Version Fixed - Withdrawable Isolation behaviour IEC 60947-3 1SDC200428F001 Common data SACE Emax 2 E1.2 Performance levels N/DC MS Rated uninterrupted current Iu @ 40°C [A] 800 [A] 1250 [A] [A] [A] [A] Poles 3 4 4 Rated service voltage Ue 750 750 1000 Rated insulation voltage Ui 1000 1000 1000 20 Rated short-time withstand current Icw (1s) [kA] 20 25 Rated short-circuit making capacity (peak value) Icm 750 V [kA] 40 53 1000 V [kA] 40 40 Utilization category (according to IEC 60947-3) SACE Emax 2 E1.2 Mechanical and electrical life with regular ordinary maintenance prescribed by the manufacturer Electrical life [Iu] < 1000 1250 [No.oper.x 1000] 20 20 Frequency [Oper./Hour] 60 60 1000 V [No.oper.x 1000] 1 1 Frequency [Oper./Hour] Note: by means of external protection relay with 500 ms maximum timing, the breaking capacity Icu at the maximum rated use voltage is equal to the value of Icw (1s). 2/10 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 10 15/04/2013 16:21:55 1SDC200431F001 1SDC200429F001 1SDC200430F001 2 E2.2 E4.2 E6.2 S/DC MS H/DC MS X/DC MS 1250 1250 4000 1600 1600 5000 2000 2000 6300 2500 2500 3200 4000 3 4 4 3 4 4 3 4 4 750 750 1000 750 750 1000 750 750 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 25 40 25 40 50 40 65 65 65 53 84 53 84 105 84 143 143 53 E2.2 84 E4.2 143 143 E6.2 < 2000 2000 2500 < 3200 3200 4000 4000 5000 6300 25 25 20 20 20 15 12 12 12 60 60 60 60 60 60 60 60 60 2 2 2 1 1 1 1 1 1 ABB catalogue | 1SDC200023D0201 | 2/11 Emax2_cap02.indd 11 15/04/2013 16:21:56 SACE Emax 2 derived versions 1SDC200435F001 1SDC200439F001 1SDC200441F001 1SDC200437F001 1SDC200438F001 1SDC200440F001 1SDC200434F001 1SDC200433F001 – Sectionalizing truck CS: in normal operating conditions of the electrical circuit, this device is inserted in the fixed part and short-circuits the upper and lower terminals of the power circuit. When maintenance activities need to be carried out, the sectionalizing truck is removed and the part of the system involved is isolated. The device can be accessorised with a keylock and padlocks for locking in the withdrawn position. 1SDC200436F001 1SDC200432F001 2 Safety is an indispensable requirement that must always be guaranteed in electrical installations. In this regard, ABB SACE offers devices developed to further increase safety standards during inspection and maintenance activities on electrical installations. In particular, in a withdrawable version, ABB SACE Emax 2 offers: – Earthing truck MT: this device enables all phases of the electrical circuit in which maintenance needs to be performed to be earthed 1). The earthing truck is available in two versions: for earth connection from the upper or lower terminals. – Earthing switch with making capacity MTP: similar to the MT device, this differs due to the presence of a mechanical stored energy control which allows the circuit to be opened and closed. Two versions of this earthing switch are also available: for earth connection from the upper or lower terminals. It can also be accessorised with a keylock or padlocks for locking in the open position. 1) The earthing circuit is dimensioned for a short-time current equal to 60% of the maximum Icw of the circuit-breaker from which it is derived (IEC 60439-1) 2/12 | 1SDC200023D0201 | ABB catalogue Emax2_cap02.indd 12 15/04/2013 16:21:57 Common data Rated service voltage Ue [V] 690 Rated insulation voltage Ui [V] 1000 Rated impulse withstand voltage Uimp [kV] 12 Frequency [Hz] 50 - 60 2 Number of poles 3-4 Version Withdrawable SACE Emax 2 E2.2 Performance levels CS MT MTP CS E4.2 MT MTP CS E6.2 MT MTP Rated uninterrupted current Iu @ 40°C 2500 2500 2500 4000 4000 4000 6300 6300 6300 Neutral pole current-carrying capacity for 4-pole CBs 100 100 100 100 100 100 50-100 50-100 50-100 Rated short-time withstand current Icw (1s) [kA] - 30 30 - 50 50 - 50 50 Other versions Corrosive substances, vibrations, shocks or very low temperatures can be present in particular applications. In this regard, SACE Emax 2 circuit-breakers offer specific solutions developed precisely for: – Aggressive environments, such as industrial processes for paper production, oil refining or water treatment, which are subject to high levels of sulphur dioxide (SO2) and hydrogen sulphide (H2S) contamination. – Antiseismic installations, for areas with seismic risk where industrial and civil activities take place and where the continuity of critical processes must be guaranteed even in the case of particular natural events. For further detail, please contact ABB SACE. ABB catalogue | 1SDC200023D0201 | 2/13 Emax2_cap02.indd 13 15/04/2013 16:21:57 Emax2_cap02.indd 14 15/04/2013 16:21:57 Protection trip units Introduction 3/2 Architecture 3/4 Protection trip units for power distribution Ekip Dip 3/6 Ekip Touch 3/10 Ekip Hi-Touch 3/20 3 Protection trip units for generators Ekip G Touch 3/24 Ekip G Hi-Touch 3/29 Protection trip units for power control Ekip Power Controller 3/32 Technical characteristics for protection trip units Protection functions 3/38 Measurement functions 3/46 ABB catalogue | 1SDC200023D0201 | 3/1 Emax2_cap03.indd 1 15/04/2013 16:45:54 Protection trip units Introduction The SACE Emax 2 Ekip protection trip units are the new benchmark for the protection, measurement and control of low voltage electrical systems. The result of ABB SACE’s experience and research, they make Emax 2 not only a circuitbreaker, but an actual Power Manager with all the functions necessary for optimal management of the system without the need for external devices. 3 The protection units are divided into two families: Ekip for distribution protection and Ekip G for generator protection. The range of trip units is available with three levels of performance, Dip, Touch and Hi-Touch, to satisfy simple to advanced applications. Exclusive functions such as the Ekip Power Controller and Network Analyzer complete the range, enabling power management and analysis of energy quality. The complete, flexible Ekip protection trip unit offering, which can be adapted to the actual level of protection required, is shown below: Fields of applications Distribution Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch Measurement and Protection of Voltage, Power, Energy Network Analyzer Power Control – – – – • with Ekip Measuring with Ekip Measuring Pro – • • • • • • • – • • • • with Ekip Multimeter Ekip Dip Ekip Touch Measurement of Voltage, Power, Energy Measurement and Protection of Current Generators with Ekip Power Controller with Ekip Power Controller Ekip Power Controller function monitors installation loads and generators, permitting the power consumed to be limited and allowing savings on electricity bills. 3/2 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 2 15/04/2013 16:45:55 The protection units for power distribution, available in the LI, LSI and LSIG versions, are suited to all distribution systems. The Ekip trip units are designed to protect a vast range of applications, such as use with transformers, motors and drives. Ekip Dip, Ekip Touch or Ekip Hi-Touch can be selected, depending on the complexity of the system, the need to take voltage or energy measurements or to include control systems in switchgear. Ekip G enables the protection of generators without the use of external devices that require dedicated relays and wiring. Ekip G increases efficiency from the design stage to installation, minimizing the time needed for realization and commissioning of the system, and ensuring high levels of accuracy and reliability of all protection devices required for running generators in applications such as naval, GenSet or cogeneration. 3 Ekip Power Controller is the new function that controls the power absorbed, thereby increasing the efficiency of the system. This ABB SACE patented function measures power and energy but also controls, without the use of complex external automation logic, loads and generators in order to optimize the power consumed. Thanks to the Network Analyzer function integrated in all Hi-Touch versions, the quality of energy in terms of harmonics, micro-interruptions or voltage dips is monitored without the need for dedicated instrumentation. This allows effective preventive and corrective action to be implemented through accurate analysis of the faults, thereby improving the efficiency of the system. 1SDC200442F001 Ekip G enables the protection of generators without the use of external devices that require dedicated relays and wiring. ABB catalogue | 1SDC200023D0201 | 3/3 Emax2_cap03.indd 3 15/04/2013 16:45:55 Protection trip units Architecture All SACE Emax 2 circuit-breakers are equipped with protection trip units that are interchangeable from the front with just a few, simple operations by the customer. There is no need to dismantle the circuit-breaker or access dangerous parts. 1SDC200444F001 3 This enables personalization of the functions available, even during commissioning or when the circuit-breaker has already been installed. In particular, SACE Ekip consists of: – Protection trip unit, available with different interfaces and versions that range from basic to more complete; it contains a latest generation microprocessor that performs all the functions of protection and control. – Ekip Measuring Module, connected internally to Emax 2, performs voltage, power and energy measurements with high accuracy without requiring any external connection or voltage transformer. The Ekip Measuring Pro version also performs all protection functions based on voltage and power without the need for external units, thereby simplifying design and construction of the system. – Interchangeable rating plug enables all protection thresholds to be adjusted according to the rated current, increasing flexibility for the customer. It is useful in installations that are prepared for future development or in cases in which the power supplied may be limited temporarily. – Main board is the mechanical housing of the trip unit, which includes a micro-controller for measuring currents and the self-protection functions. The separation of trip units ensures excellent reliability and immunity to conducted and radiated emissions. Integrated new generation Rogowski sensors, which are sensitive to the true r.m.s. value of the current, guarantee high accuracy of both measurements and protection. 3/4 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 4 15/04/2013 16:45:56 All protection trip units of the SACE Emax 2 family are self-powered by current that crosses the circuit-breaker. They guarantee excellent reliability thanks to a system of self-control of internal connections. The setting, testing and downloading of reports can be carried out directly from a Smartphone, Tablet or PC. In addition, the commissioning stage can be further accelerated, minimizing the possibility of errors, by directly configuring the protection trip unit with the DOC design software settings. 3 1SDC200445F001 Cartridge-type modules that are easily installed on-board enable the units to be integrated into the most complex systems. Additional functions can be created, such as: – Synchrocheck, to check the synchronization of the two half-busbars before enabling circuit-breaker closing; – Communication with all supervision systems available in the Modbus, Profibus and DeviceNet protocols as well as the modern Modbus TCP, Profinet and EtherNet/IP protocols; – Integration into Smart Grids thanks to the possibility of communicating without the assistance of any external converter, according to standards (IEC 61850) already in use in the automation systems of high and medium voltage substations; – Multi-voltage supply module, which enables the protection trip unit and modules present to be supplied with any auxiliary voltage available in direct or alternating current; – Programmable logic management thanks to Ekip Signalling modules that make a high number of electrical input and output contacts; – Logical interlocks between circuit-breakers, which can be made with the Ekip Link proprietary communication protocol, avoiding complex wiring thanks to the transmission of all signals via bus; – Increase of current-carrying capacity in switchgear of the circuit-breaker by means of Ekip Fan which continuously monitors the internal temperature at the fixed part and activates cooling fans if the temperature is too high. ABB catalogue | 1SDC200023D0201 | 3/5 Emax2_cap03.indd 5 15/04/2013 16:45:59 Protection trip units for power distribution Ekip Dip 3 Characteristics Ekip Dip is the new protection trip unit of the SACE Emax 2 family for all applications in which high accuracy and reliable protection against overcurrent are required. Ekip Dip offers a complete set of standard protection functions. Dedicated LEDs allow the fault that caused tripping to be determined. The unit is – Ekip Dip – Ekip Dip – Ekip Dip available in the following versions: LI LSI LSIG 1 2 4 3 5 1SDC200446F001 6 Key: 1. Power-on LED for signalling correct operation (watchdog) 2. LEDs for alarm signalling of L, S, I and G protection functions and diagnostics 4. Dip switches for setting the network frequency and neutral protection device 5. Pushbutton for test and for indicating the cause of tripping 6. Test and programming connector 3. Dip switches for setting the protection functions 3/6 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 6 15/04/2013 16:45:59 Protection functions Ekip Dip offers overcurrent protection functions and, in the event of tripping, controls the opening of the circuit-breaker, preventing it from closing again unless it has been reset by the operator (lockout device – code ANSI 86). Overload (L - ANSI 49): with inverse long-time delay trip of the type t = k/l2 available with 25 current thresholds and 8 curves, it provides effective protection of all systems. A pre-alarm warning is also available on reaching 90% of the threshold set. t I1 t1 3 I Time-delayed overcurrent (S - ANSI 51 & 50TD): with constant tripping time (t = k), or with constant specific let-through energy (t = k/l2), it provides 15 current thresholds and 8 curves, for fine adjustment. The function can be excluded by setting the dip switch combination to “OFF”. t I2 t2 I Thermal memory: for L and S protection functions, this is used to protect components, such as transformers, from overheating following an overload. The function, which can be enabled by the Ekip Connect software, adjusts the protection tripping time according to the length of time that has elapsed since the first overload, taking into account the amount of heat generated. t L cold curve S hot curve I Instantaneous overcurrent (l - ANSI 50): with tripping curve without intentional delay, it offers 15 tripping thresholds and can be excluded by setting the dip switch combination to “OFF”. t I3 I Earth fault (G - ANSI 51N & 50NTD): with tripping time independent of current (t = k) or constant specific let-through energy (t = k/l2). The function can be excluded by setting the dip switch combination to “OFF”. t I4 t4 I t 100% 200% 50% 150% Neutral protection: available at 50%, 100% or 200% of the phase currents, or disabled, it is applied to the overcurrent protections L, S and I. L S I I ABB catalogue | 1SDC200023D0201 | 3/7 Emax2_cap03.indd 7 15/04/2013 16:45:59 Protection trip units for power distribution Ekip Dip 3 Measurements The Ekip Dip unit measures phase and neutral current with great accuracy: 1% including the current transformers in the 0.2 ... 1.2 In range (class 1 in accordance with IEC 61557-12). Using the current sensors in the circuit-breaker and without the need to install an external measuring system, it is possible to view the measurements by the display on the front of the Ekip Multimeter and Ekip Control Panel. Ekip Dip also records the characteristics of the circuit-breaker, to enable a rapid analysis in the event of maintenance: – Maximum and average current values per phase; – Date, time, fault current per phase and type of protection tripped over the last 30 trips; – Date, time and type of operation of the last 200 events (for example: opening/closing of circuit-breaker, pre-alarms, editing settings); – Number of mechanical and electric operations of the circuit-breaker; – Total operating time; – Contact wear; – Date and time of the last maintenance carried out, in addition to the estimate of the next maintenance required; – Circuit-breaker identifying data: type, serial number, firmware version, name of the device as assigned by the user. The values can be displayed on the front of the Ekip Multimeter or Ekip Control Panel or by Ekip Connect software on a Smartphone, Tablet or PC by using the communication units Ekip T&P or Ekip Bluetooth. Watchdog All the protection trip units of the SACE Emax 2 family ensure high reliability owing to an electronic circuit that periodically controls the continuity of the internal connections (trip coil, rating plug and current sensors). In the event of a malfunction, the LEDs indicate the corresponding alarm to enable the fault to be identified rapidly. Furthermore, Ekip Dip detects and indicates that the circuitbreaker has been opened because one of the protection functions has been tripped (Ansi BF code). In order to preserve the correct operation of the unit, Ekip Dip is also provided with self-protection against abnormal temperature (OT) inside the protection trip unit. The user can set it to open the circuit-breaker or to merely indicate an alarm. User interface Ekip offers a great variety of thresholds and trip times, the protections can be set by dip-switches. Up to 5 LEDs are also available (depending on the version) to indicate correct operation or alarms. The interface always enables the status of the installation to be identified clearly and quickly: – correct operation (green LED) – overcurrent pre-alarms or alarms – presence of self-control functions alarms – maintenance interval expired – indication of tripped protection after a fault The protection tripped indication is activated by pressing the iTest key, and operates without the need of an external power supply because a battery is installed inside the unit. Communication The Ekip Bluetooth wireless communication unit enables the operator to interact with the protection trip unit by computer, Smartphone or Tablet. In fact, the free Ekip Connect software for Smartphones, Tablets and PC, enables measurements and fault data to be read and alarm status and information on the circuit-breaker or maintenance to be displayed. It is also possible to set parameters such as date, time and thermal memory and for the records to be reset. 3/8 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 8 15/04/2013 16:45:59 Test function The test port on the front of the protection trip unit can be used to run the circuit-breaker tests by connecting one of the following devices: – Ekip TT to run the trip test, the LEDs test and check absence of alarms detected by the watchdog function; – Ekip T&P to permit not only the trip test and LEDs test but also to run the test of the individual protection functions and save the relative report; – ITest key that is pressed to run the battery test when the circuit-breaker is disconnected. 3 Supply The Ekip Dip protection trip unit does not require an external supply for the protection functions or for the alarm indication functions because it is self-supplied by the current sensors installed on the circuit-breaker. A three-phase 100A current suffices to activate the LED indications. The Ekip Supply module enables an auxiliary supply to be easily connected and is able to receive both a direct current supply (24-48VDC or 110-240VDC) and an alternating current (110-240VAC) to activate additional functions such as: – G protection at values below 100A or below 0.2 In; – connecting to external devices such as Ekip Multimeter and Ekip Control Panel; – recording the number of operations. The Ekip Dip protection trip unit also has a battery that enables the indication of the cause of the fault to be viewed for an unlimited time after tripping. In addition to that, the battery enables date and time to be maintained and updated, thus ensuring the chronology of the events. On the other hand, when the unit is switched off, the battery test can be run by simply pressing the iTest key. Supply Ekip Supply Nominal voltage 24-48V DC 110-240V AC/DC Voltage range 21.5 - 53V DC 105-265V AC/DC Rated power (including modules) 10W max. 10W max. Inrush current ~10 A for 5 ms ~10 A for 5 ms Whenever cartridge modules are not used in the terminal box area, the trip unit can be supplied by means of a galvanically isolated 24V DC auxiliary voltage. ABB catalogue | 1SDC200023D0201 | 3/9 Emax2_cap03.indd 9 15/04/2013 16:45:59 Protection trip units for power distribution Ekip Touch Characteristics Ekip Touch is the new protection trip unit for SACE Emax 2 that provides a complete series of protections and high accuracy measurements of all electric parameters and can be integrated perfectly with the most common automation and supervision systems. 3 The simple and intuitive interface enables the operator to access all the information and settings rapidly and easily by minimizing installation and commissioning time. The unit is available in the versions: – Ekip Touch LI – Ekip Touch LSI – Ekip Touch LSIG 2 3 4 5 1 6 1SDC200466F001 7 Key: 4. Alarm LED 1. Wide high-resolution colour touchscreen display 5. Home pushbutton to return to home page 2. Power-on LED to indicate correct operation (watchdog) 6. Pushbutton for test and indicating cause of trip 7. Test and programming connector 3. Pre-alarm LED 3/10 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 10 15/04/2013 16:46:00 Protection functions Ekip Touch enables all the protection functions to be set with a few simple steps directly from the wide touchscreen display. If the circuit breaker is tripped it must be reset manually or electrically by the operator (lockout relay – code ANSI 86). t Extremely Inverse Very Inverse Standard Inverse Overload (L - ANSI 49): available with three different types of trip curve: 1. t = k/l2 with inverse long time; 2. IDMT in accordance with IEC 60255-3 for coordination with medium voltage protections, that are available according to the Standard Inverse (SI), Very Inverse (VI) and Extremely Inverse (EI) curves; 3. with t = k/l4 curve for better coordination with upstream circuit-breakers or with fuses. 3 I The thresholds can be fine tuned (for example 1A for circuit-breaker E1.2 1000A) and the timings to the second can be set directly from the display. The settable pre-alarm indicates the set threshold is reached before the protection is tripped. The protection can be disabled by rating plug L=off. Time-delayed overcurrent (S - ANSI 51 & 50TD): with constant trip time (t = k), or constant specific letthrough energy (t = k/l2). t I2 t2 I Thermal memory: for protections L and S it is used to protect the components, such as transformers, against overheating following overloads. The protection adjusts the trip time of the protection according to how much time has elapsed after the first overload, taking account of the overheating caused. t L cold curve S hot curve I Instantaneous overcurrent (l - ANSI 50): with trip curve without intentional delay. t Closing on short-circuit (MCR): the protection uses the same algorithm of the protection l, limiting operation to a settable time window from the closing of the circuit-breaker. The protection can be disabled, also alternatively to protection l. The function is active with an auxiliary supply. I3 I Earth fault (G - ANSI 51N & 50NTD): with trip time independent of the current (t = k) or with constant specific let-through energy (t = k/l2). A pre-alarm indication is also available when 90% of the threshold is reached to activate corrective measures before the protection is tripped. The function also enables the trip to be excluded so that only the alarm is indicated, for use in installations where continuity of service is an essential requirement. t I4 t4 I ABB catalogue | 1SDC200023D0201 | 3/11 Emax2_cap03.indd 11 15/04/2013 16:46:00 Protection trip units for power distribution Ekip Touch Earth fault on toroid (G ext - ANSI 51G & 50GTD): with trip time independent of the current (t = k) or with constant specific let-through energy (t = k/l2). Pre-alarm that 90% threshold has been reached permit the fault to be reported to supervision systems without interruption of continuity. The protection uses the external toroid installed, for example, on the star centre of the transformer, and is an alternative to the G and Rc functions. The function is active with an auxiliary supply. t I4 t4 I 3 t Neutral protection: available at 50%, 100%, 150% or 200% of the phase currents, or disabled, it is applied to the overcurrent protections L, S and I. 100% 200% 50% 150% L S I I t steady state start-up I Start-up function: enables protections S, I and G to operate with higher trip thresholds during the starting phase, avoiding untimely trips due to high inrush currents of certain loads (motors, transformers, lamps). The starting phase lasts 100 ms to 30 s and is recognized automatically by the trip unit: – at the closing of the circuit-breaker with a self-supplied trip unit; – when the peak value of the maximum current exceeds the set threshold (0.1…10 x In) with an externally supplied trip unit; a new start-up is possible after the current falls below the threshold. Current unbalance (IU – ANSI 46): with constant trip time (t = k), protects from an unbalance between the currents of the single phases protected by the circuit breaker. t I7 t7 Zone 3 Zone 2 Zone 1 I Zone selectivity for S and G protection (ANSI 68): can be used to minimize circuit-breaker trip times closer to the fault. The protection is provided by connecting all the zone selectivity outputs of the trip units belonging to the same zone and taking this signal to the trip unit input that is immediately upstream. Each circuit-breaker that detects a fault reports it to the circuit-breaker upstream; the circuit-breaker thus detects the fault but does not receive any communication from those downstream and opens without waiting for the set delay to elapse. It is possible to enable zone selectivity if the fixed-time curve has been selected and the auxiliary supply is present. Current thresholds: this function enables the realization of four independent thresholds to be indicated in order to enable corrective action implementation before the overload L protection trips the circuit-breaker. For example, by disconnecting loads located downstream of the circuit-breaker that are controlled by Ekip Signalling. Power Controller: Power controller function (optional) with Ekip Measuring module. 3/12 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 12 15/04/2013 16:46:00 1SDC200467F001 Protection functions with Ekip Measuring Pro The Ekip Touch protection functions can be further increased by using the Ekip Measuring Pro measuring and protection module. With this module, all the protection functions linked to voltage, frequency and power can be enabled, thus making Ekip Touch a multifunction unit that can measure, control and protect even the most complex installation. A different operating mode can be chosen for each protection function: 1. Active: protection enabled by opening of the circuit-breaker when the threshold is reached; 2. Only alarm: protection active, with only alarm indication when the threshold is reached; 3. Deactivated: protection disabled. Furthermore, when the voltage and frequency protections are activated, they indicate an alarm status even when the circuit-breaker is open so that a fault can be identified before the circuit-breaker closes. 3 Undervoltage (UV - ANSI 27): with constant trip time (t = k), function is tripped when phase voltage falls below set threshold. t U8 t8 V Overvoltage (OV - ANSI 59): with constant trip time (t = k), function is tripped when phase voltage exceeds the set threshold. t U9 t9 t8 V Underfrequency (UF - ANSI 81L): with constant trip time (t = k), function is tripped when network frequency falls below set threshold. t f12 t12 f Overfrequency (OF - ANSI 81H): ): with constant trip time (t = k), function is tripped when network frequency exceeds the set threshold. t f13 t13 f ABB catalogue | 1SDC200023D0201 | 3/13 Emax2_cap03.indd 13 15/04/2013 16:46:00 Protection trip units for power distribution Ekip Touch mean Voltage unbalance (VU – ANSI 47): with constant trip time (t = k), protects against an unbalance between the voltages of the individual phases that are protected by the circuit-breaker. U14 U1 U2 U3 3 PE L1 L2 L3 N Residual current (Rc – ANSI 64 & 50NDT): with constant temperature (t=k) protects against indirect contacts and is integrated into Ekip Touch by a dedicated residual current rating plug and external toroid. The protection is an alternative to the functions G and Gext. LOAD Reverse active power (RP - ANSI 32R): with constant trip time (t = k), function is tripped when total active power – in the opposite direction of the current - exceeds the set threshold. M RP In addition to the protection functions, the following indication and control functions are available to warn the user that a given condition has been reached. The active indications are always shown on the display and are also available by communication on the system bus (with Ekip Com modules) or electrical indication (with Ekip Signalling modules). Synchrocheck (SC - ANSI 25): the synchronism control function compares the voltages in the module, the frequency and phase of the two circuits to which the circuit-breaker is connected. Ekip Touch indicates that conditions have been reached that enable the two lines to be made parallel. The function is available with two work modes: – In systems with both busbars supplied, where synchronism is determined by: 1. voltage of the two half-busbars above the Ulive threshold for the set time 2. difference of the module of the two voltages below the threshold 'U 3. difference of the frequency of the two voltages below the threshold 'f 4. difference of the phase of the two voltages below the threshold ' 5. desirable time for synchronism condition tsyn 6. circuit-breaker open – In systems with an out-of-service line (dead busbar), where the synchronism condition is determined by the concurrence of the following conditions for the tref set time: 1. voltage of the active half-busbar above threshold Ulive 2. voltage of the dead half-busbar below threshold Udead 3. circuit-breaker open U, f, In both cases, synchronism consent is withdrawn when one of the above conditions is missing and it has not been less than 200ms from the change of the circuit-breaker condition (when the relationship has been set). The indication of reached synchronism is available directly as an electrical indication via a contact that is always supplied with the module. The function can be activated simply by connecting the Ekip Synchrocheck module to any Ekip Touch provided with an Ekip Measuring Pro module. V1 Cyclical direction of the phases (ANSI 47): indicates an alarm through inversion of the phases sequence. V3 V2 Power factor (ANSI 78): available with a three-phase threshold, warns when the system operates with a power factor that is less than the set power factor. 3/14 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 14 15/04/2013 16:46:01 1SDC200470F001 1SDC200469F001 1SDC200468F001 Measurements Measurements and meters All versions of the Ekip Touch unit measure the RMS value of the currents of the three phases (L1, L2, L3) and of neutral (Ne) with 1% accuracy in the 0.2 to 1.2 In range (class 1 in accordance with IEC 61557-12). The complete range of measurement is from 0.03 to 16x In, where In is the value of the rating plug. The display shows the current of the most loaded phase both in numeric and analogue format on an ammeter with a 0-125% In scale for rapid identification of the load of the circuit-breaker. 3 Alternatively, bar graphs that show the currents of the three phases and of neutral on a 0-125% In scale in addition to the numeric value of the most loaded phase can be selected as the default page. The bar graphs are yellow in the event of a pre-alarm and red in the event of an overload to enable an irregular condition to be identified immediately. Where applicable, the measurement of the earth fault current is shown on a dedicated page. The ammeter can operate both in self-supplied mode and with auxiliary voltage. In the latter case, the display always has back lighting and the ammeter is also active at currents below 100A. Adding the Ekip Measuring or Ekip Measuring Pro module to Ekip Touch enables Ekip Touch to be used as a multimeter to measure the values of: – Voltage: phase-phase, phase-neutral (accuracy 0.5%); – Power: active, reactive, apparent (accuracy 2%); – Energy: active, reactive, apparent (accuracy 2%); – Frequency (accuracy 0.2%); – Power factor by phase and total; – Peak factor. Maximum values and values register The Ekip Touch unit is able to supply the measurement trend of certain parameters over a settable period of time such as: average power, maximum power, maximum and minimum current, maximum and minimum voltage. The values of the last 24 time intervals are recorded in the unit with a relative timestamp and can be consulted directly from the display or remotely using one of the available communication protocols. The communication can also be used to synchronize the recording time interval. Data logger Ekip Touch is always supplied with the exclusive Data Logger (register) function that stores with high sampling frequency the instantaneous values of all the measurements in two memory buffer registers. The data can be easily downloaded by the Ekip Connect unit and transferred to any personal computer. This enables the current and voltage waveforms to be analyzed for rapid fault analysis. The function continuously stores and stops recording, with a selectable delay, whenever the event set by the user occurs (e.g. trip or alarm). In this manner, it is possible to analyze the complete evolution of the fault: from the start to its complete elimination. ABB catalogue | 1SDC200023D0201 | 3/15 Emax2_cap03.indd 15 15/04/2013 16:46:02 Protection trip units for power distribution Ekip Touch Information on trip and opening data If a trip occurs, Ekip Touch stores all the information that is required for rapid identification and elimination of the causes: – Protection tripped – Opening data (current, voltage or frequency) – Time-stamping (data, time and consecutive opening number) 3 1SDC200471F001 If the iTest key is pressed, the trip unit displays all these data directly on the display. No auxiliary supply is required. The information is also available to the user with the circuit-breaker open or without current flow, due to the battery installed inside the unit. Maintenance indicators A complete set of information about the circuit-breaker and its operation is available for effective fault analysis and preventive scheduling of maintenance. All the information can be seen from the display or from a PC using a communication unit. In particular: – Date, time, fault current by phase and type of protection tripped over the last 30 trips; – Date, time and type of operation of the last 200 events (example: opening/closing of circuit-breaker, pre-alarms, editing of settings, ect.); – Number of operations of the circuit-breaker: divided into mechanical operations (no current), electrical operations (with current) and protection function (trip); – Contact wear estimated in function of the number and type of openings; – Total operating time of the circuit-breaker with circulating current; – Date and time of the last maintenance session, scheduling of the next maintenance session; – Circuit-breaker identifying data: type, serial number, firmware version, device name assigned by the user. All the information can be viewed directly from the display and from a Smartphone, Tablet (with Ekip Bluetooth) or PC using the front port of the trip unit or the system communication. 3/16 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 16 15/04/2013 16:46:02 Watchdog All of the trip units in the SACE Emax 2 family ensure high reliability because of an electronic circuit that periodically controls continuity of the internal connections (trip coil, rating plug and each current sensor). In the event of an alarm, a message is shown on the display, and if it is set during the installation phase, the trip unit can command the opening of the circuit-breaker. If a protection function intervenes, Ekip Touch always checks that the circuit-breaker has been opened by auxiliary contacts that indicate the position of the main contacts. Otherwise, Ekip Touch indicates an alarm (ANSI BF code - Breaker Failure) to be used to command the opening of the circuit-breaker located upstream. Ekip also contains self-protection that preserves the correct operation of the unit against abnormal temperatures (OT) inside the protection trip unit. The user disposes of the following indications or controls: 3 – “Warning” LED for temperature below -20°C or above +70 °C, at which the trip unit operates correctly with the display switched off – “Alarm” LED for temperature outside the operating range, at which the trip unit commands the opening of the circuit-breaker (if set during the configuration phase). 1SDC200472F001 User interface All Ekip Touch operations are simple and intuitive due to the wide graphic colour touchscreen display. For example, all the main information is listed on one page (settable by default), thus enabling the state of the installation to be identified rapidly: maximum current, maximum voltage, active, reactive, apparent power and energy. In addition, the use of Ekip Touch is further simplified by the possibility of scrolling through the menu and reading the alarms in one of the languages that can be set directly from the display: Italian, English, German, French, Spanish, Chinese, Russian, Turkish and Thai. The home pushbutton enables you to return, at any moment, to the main page and the iTest key enables the information to be viewed after a circuit-breaker trip and test. As in the previous generation of trip units, a password system is used to manage “Read” or “Edit” modes. The default password, 00001, can be edited by the user. The protection parameters (curve and trip thresholds) are settable in “Edit” mode whereas it is always possible to consult the information in “Read” mode. 1SDC200473F001 On the front of the trip unit there are also two LEDs: a pre-alarm LED (square yellow LED) and an alarm LED (red triangular LED); a message on the display always accompanies the flashing of the LEDs for clear identification of the type of event. The list of all the alarms active at that moment can be viewed by simply touching the display on the white strip in the bottom left of the alarms zone. Ekip Touch is also supplied with a front port that permits a temporary connection to devices for test, supply or communication (for example Ekip T&P). ABB catalogue | 1SDC200023D0201 | 3/17 Emax2_cap03.indd 17 15/04/2013 16:46:03 Protection trip units for power distribution Ekip Touch 3 Communication Communication modules that can be installed inside the circuit-breaker enable Ekip Touch to be integrated into the most modern supervision systems with protocols: – IEC 61850 – Modbus TCP – Modbus RS-485 – Profibus – Profinet – DeviceNet – EtherNet/IP The integration into communication systems enables measurements, statuses and alarms to be programmed and viewed by remote functions. If the circuit-breaker has to be opened and closed remotely, the Ekip Com Actuator module can be installed in the circuit-breaker front, in the right-hand accessories chamber. For each circuit-breaker, several communication modules with different protocols can be used simultaneously; for example, this enables the circuit-breaker to be connected to the Ekip link system to obtain local supervision from the front of the switchgear and to simultaneously integrate it into a communication network. In addition, for applications requiring very high reliability, up to two modules of the same protocol can be inserted by use of the redundant version that enables two different addresses to communicate on the same bus. Test function For circuit-breaker testing it is possible to use the test port and the iTest key positioned on the front of the protection trip unit. The available functions are: – trip test, test of the display and of the LEDs and check of absence of alarms detected by the watchdog function using Ekip TT (always supplied with Ekip Touch); – test of the single protection functions and saving of the report, in addition to the trip test and test of the display, using Ekip T&P; – test of the battery with the circuit-breaker switched off by pressing the iTest key. 3/18 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 18 15/04/2013 16:46:03 Supply The Ekip Touch protection trip unit is self-supplied by the current sensors and does not require an external supply for the basic protection functions or for the alarm indication functions. All protection settings are stored in a non-volatile memory that maintains the information, even without a power supply. To activate the indication functions the ammeter and the display, a 100A three-phase current suffices. An auxiliary supply can easily be connected. The Ekip Supply module can be connected to supplies of both direct current and alternating current to activate additional functions such as: – using the unit with circuit-breaker open; – using additional modules such as Ekip Signalling and Ekip Com; – connection to external devices such as Ekip Multimeter and Ekip Control Panel; – recording the number of operations; – G protection with values below 100A or below 0.2 In; – zone selectivity; – Gext and MCR protection functions. Supply Ekip Supply Nominal voltage 24-48V DC 110-240V AC/DC Voltage range 21.5-53V DC 105-265V AC/DC Rated power (including modules) 10W max. 10W max. Inrush current ~10 A for 5 ms ~10 A for 5 ms 3 The Ekip Supply module allows the cartridge modules to be used in the terminal box area. Otherwise, the trip unit can be supplied by means of a galvanically isolated 24 VDC auxiliary voltage. The Ekip Measuring Pro module can supply the Ekip Touch trip unit with line voltage above 85V. In addition, if the module is installed with voltage pick-ups on the supply side, the trip unit can be used even if the circuit-breaker is open. The Ekip Touch protection trip unit is also supplied with a battery that enables the cause of the fault to be indicated after a trip, without a time limit. In addition, the battery enables date and time to be updated, thus ensuring the chronology of the events. When Ekip Touch is operating, it uses an internal control circuit to indicate automatically that the battery is flat. On the other hand, when the unit is switched off the battery test can be run by simply pressing the iTest key. ABB catalogue | 1SDC200023D0201 | 3/19 Emax2_cap03.indd 19 15/04/2013 16:46:03 Protection trip units for power distribution Ekip Hi-Touch Characteristics The Ekip Hi-Touch of SACE Emax 2 is a high-performance multifunction unit that is extraordinarily versatile and can be used in even the most complex installations. Ekip Hi-Touch, in fact, features exclusive functions such as: directional protection, restricted earth fault and dual setting of the protections. In addition, Ekip Hi-Touch is supplied 3 with the exclusive Network Analyzer function that can monitor the quality of the power absorbed by the installation in accordance with existing standards. Ekip Hi-Touch boasts all the features of Ekip Touch; as standard, it features the measuring and protection module Ekip Measuring Pro and can also be fitted, like Ekip Touch, with the additional features provided by the internal modules and by the external accessories. The front interface of the unit, which is common to Ekip Touch, is extremely simply because of the touchscreen colour display; it is able to show measurements, bar graphs and sine curves of the different electrical values. The unit is available in the versions: – Ekip Hi-Touch LSI – Ekip Hi-Touch LSIG 2 3 4 5 1 6 8 Key: 5. Home pushbutton to return to home page 1. Wide high-resolution colour touchscreen display 2. Power-on LED indicating correct operation 6. Pushbutton for test and for indicating cause of the trip 3. Pre-alarm LED 7. Test and programming connector 4. Alarm LED 8. Ekip Measuring Pro module, with relative LED power on 1SDC200470F001 1SDC200474F001 7 3/20 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 20 15/04/2013 16:46:03 Protection functions The Ekip Hi-Touch trip unit has the following protection functions, which it shares with Ekip Touch: – Overload (L – ANSI 49); – Time-delayed overcurrent (S – ANSI 51 & 50TD); – Thermal memory; – Instantaneous overcurrent (I – ANSI 50); – Closing on short-circuit (MCR); – Earth fault (G – ANSI 51N & 50NTD); – Earth fault on toroid (G ext – ANSI 51G & 50GTD) – Neutral protection; – Start-up function; – Zone selectivity for functions S and G (ANSI 68); – Current unbalance (IU – ANSI 46); – Undervoltage (UV – ANSI 27); – Overvoltage (OV – ANSI 59); – Underfrequency (UF – ANSI 81L); – Overfrequency (OF – ANSI 81H); – Voltage unbalance (VU – ANSI 47); – Residual current (Rc – ANSI 64 & 50NTD); – Reverse active power (RP – ANSI 32R); – Synchrocheck (SC – ANSI 25, optional); – Cyclical direction of the phases (ANSI 47); – Power factor (ANSI 78); – Current thresholds; – Power Controller function (optional). 3 The following protections are also available: Second time-delayed overcurrent protection (S2 – ANSI 50TD): in addition to the standard protection S, a second (excludible) time-constant protection is available that enables two independent thresholds to be set in order to ensure precise selectivity, especially in highly critical conditions. protection zone ∆ Y 64REF Second protection against earth fault (ANSI 50GTD/51G & 64REF): whereas with Ekip Touch the user has to choose between implementation of the protection G by internal current sensors (calculating the vector sum of the currents) or G ext external toroids (direct measurement of the earth fault current), Ekip Hi-Touch offers the exclusive feature of simultaneous management of both configurations by two independent earth fault protection curves. Owing to this characteristic, the trip unit is able to distinguish a non-restricted earth fault and then activate the opening of Emax 2, from a restricted earth fault, and to thus command the opening of the medium voltage circuit-breaker. Another possible configuration is with the residual current protection replacing the Gext protection, whilst the G protection remains active. The residual current protection is activated in the presence of the residual current rating-plug and of the toroid. ABB catalogue | 1SDC200023D0201 | 3/21 Emax2_cap03.indd 21 15/04/2013 16:46:03 Protection trip units for power distribution Ekip Hi-Touch Directional overcurrent (D – ANSI 67): the protection is able to recognize the direction of the current during the fault period and thus detect if the fault is upstream or downstream of the circuit-breaker. The protection, with fixed time trip curve (t=k), intervenes with two different time delays (t7bw and t7fw), according to the current direction. In ring distribution systems, this enables the distribution portion to be identified in which the fault occurred and to disconnect it while maintaining the operation of the rest of the installation. 3 Generator LOAD B LOAD C LOAD A Forward power flow Backward power flow FAULT Zone selectivity for protection D (ANSI 68): enables the possibility to connect circuit-breakers among them, that in case of fault rapidly isolate the fault area, disconnecting the installation only at the level nearest to the fault, maintaining the operation of the rest of the installation. The function is particularly useful in ring and grid installations where, in addition to the zone, it is also essential to define the flow direction of the power that supplies the fault. It is possible to enable directional zone selectivity alternatively to the zone selectivity of the protections S and G, and in the presence of an auxiliary supply. Start-up function for protection D: enables higher trip thresholds to be set at the outgoing point, as available for protections S, I and G. t Second protection against undervoltage and overvoltage (UV2 and OV2 – ANSI 27 and 59): enables two minimum and maximum voltage thresholds to be set with different delays in order to be able to discriminate, for example, between voltage dip transients due to the start-up of a motor and an actual fault. U9 t9 U16 t16 V t Second protection against underfrequency and overfrequency (UF2 and OF2 – ANSI 87L and 87H): enables two minimum and maximum frequency thresholds to be set simultaneously. For example, only an alarm can be set to be tripped when the first threshold is reached, and the circuit-breaker can be set to be opened when the second threshold is reached. f17 f12 t17 t12 f Dual setting of protections: Ekip Hi-Touch can store a set of alternative parameters for all protections. This second series (set B) can replace, if necessary, the default series (set A) by an external control. The control can be given when the network configuration is edited, for example when an emergency source is activated in the system, changing the load capacity and the short-circuit levels. Another typical application is protecting the operator opposite the switchgear against the electric arc. In this case, protection delays are minimized to safeguard the operator (Set A), whereas in the absence of an operator the protections are set to ensure selectivity with the circuit-breakers downstream (Set B). It is possible to activate series B by: – – – – Digital input available with an Ekip Signalling module; Communication network, by means of one of the Ekip Com communication modules; Directly from the Ekip Hi-Touch display; By a settable internal time, after the circuit-breaker has closed. 3/22 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 22 15/04/2013 16:46:04 Measurements The Ekip Hi-Touch trip unit offers a complete series of measurements, common to Ekip Touch: – Measurements and counters: currents, voltage, power, energy; – Maximum values and value log; – Data logger; – Information on the trip and opening data; – Maintenance indicators. 3 Ekip Hi-Touch integrates the exclusive Network Analyzer function, which analyzes the quality of energy consumed by the installation, in accordance with the provisions of international standards EN50160 and IEC 61000-4-30, in terms of harmonic content, average value and long or short term changes in voltage. These events can cause malfunctions in the switchgear and a reduction in their lifespan, as well as increasing losses and reducing the energy efficiency of the installation. It is therefore increasingly important to assess the quality of the energy and the economic impact it has on the productive process, so that the appropriate preventive and corrective actions can be taken. With Ekip Hi-Touch, the causes of an increase in power lost in transformers or motors, or a reduction in the lifespan of cables and capacitors, can be identified without the need to install any external instrumentation. The Network Analyzer function performs continuous monitoring of the quality of energy, and shows all results through a display or communication module. In particular: – Hourly average voltage value: in accordance with international standards, this must remain within 10% of the rated value, but different limits can be defined according to the needs of the installation. The positive sequence voltage is obtained from the three line voltages and compared with the limits. If the limits are exceeded, Ekip Hi-Touch generates a signalling event. The quantity of these events is stored in a suitable counter. The counter values are available for each of last 7 days, as well as the total. The measures availabe are the positive and negative sequence voltages and positive and negative sequence currents of the last interval monitored. The time of the calculation of the average values can be set between 5 minutes and 2 hours. – Interruptions / short dips in voltage (voltage interruptions / voltage dip): if the voltage remains below the threshold for more than 40ms, Ekip Hi-Touch generates an event that is counted in a dedicated log. The voltage is monitored on all lines. – Short voltage spikes (voltage transients, spikes): if the voltage exceeds the threshold for 40ms, set for a pre-determined time, Ekip Hi-Touch generates an event that is counted. – Slow voltage sags and swells (voltage sag / voltage swell): when the voltage goes outside the range of acceptable limit values for a time greater than the one set, Ekip Hi-Touch generates an event that is counted. Three values can be configured for voltage sags and two for voltage swells, each of which associated to a time limit: this enables us to verify whether the voltage remains within a curve of values that are acceptable by equipment such as computers. The voltage is monitored on all lines. – Voltage unbalances: if the voltages are not equal or the phase displacements between them are not exactly 120°, an unbalance occurs, which is manifested with a negative sequence voltage value. If this limit exceeds the threshold value set, an event is stored which is counted. – Harmonic analysis: the harmonic content of voltages and currents, measured to the 50th harmonic, as well as the value of total harmonic distortion (THD), is available in real time on the display or through the communication modules. Ekip Hi-Touch also generates an alarm if the THD value or the magnitude of at least one of the harmonics exceeds the values set. The voltage is monitored on all lines and currents on all phases. All information can be displayed directly on the screen or on a smartphone, tablet or PC using the front port of the trip unit (with Ekip Bluetooth) or installation communication. Other functions Ekip Hi-Touch integrates all the features in terms of user interface, communication, test and supply described for Ekip Touch equipped with Ekip Measuring Pro. ABB catalogue | 1SDC200023D0201 | 3/23 Emax2_cap03.indd 23 15/04/2013 16:46:04 Protection trip units for generators Ekip G Touch Characteristics Ekip G Touch by SACE Emax 2 is the new protection trip unit designed for use in applications with generators, such as Genset, cogeneration and marine applications, in conformity to international standards IEC 60034-1 and IEEE C37.102. Ekip G Touch has been approved by the main shipping registers and 3 enables the number of components installed, such as external protection devices, current sensors, voltage transformers and the relative cabling, to be reduced. The reductions allow the installation to be significantly simplified. In addition, all the protection functions can be tested individually, using the Ekip T&P device that enables the function to be tested before commissioning. The unit is available in the Ekip G Touch LSIG version and features all the characteristics provided by Ekip Touch. The Ekip Measuring Pro measuring and protection module is supplied as standard and, like Ekip Touch; the functions can be increased further using the internal modules and the external accessories. The front interface of the unit, which is common to the Ekip Touch family, is characterised by a wide, high resolution touchscreen display that is simple to use and displays measurements and alarms clearly and accurately. 2 3 4 5 1 6 8 Key: 5. Home pushbutton to return to home page 1. Wide, high resolution touchscreen display 2. Power-on LED indicating correct operation 6. Pushbutton for test and for indicating cause of the trip 3. Pre-alarm LED 7. Test and programming connector 4. Alarm LED 8. Ekip Measuring Pro module with relative poweron LED 1SDC200470F001 1SDC200475F001 7 3/24 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 24 15/04/2013 16:46:05 Protection functions The Ekip G Touch trip unit provides all the protection functions of Ekip Touch and, in addition, provides a series of dedicated generator protections. If Ekip is tripped, it opens the circuit-breaker and prevents it from closing again until it has been reset manually or electrically by the operator (lockout relay – code ANSI 86). The trip unit is provided with the following protection functions: – Overload (L – ANSI 49); – Time-delayed overcurrent (S – ANSI 51 & 50TD); – Thermal memory; – Instantaneous overcurrent (I – ANSI 50); – Closing on short circuit (MCR); – Earth fault (G – ANSI 51N & 50NTD); – Earth fault on toroid (G ext – ANSI 51G & 50GTD) – Neutral protection; – Start-up function; – Zone selectivity for functions S and G (ANSI 68); – Current unbalance (IU – ANSI 46); – Undervoltage (UV – ANSI 27); – Overvoltage (OV – ANSI 59); – Underfrequency (UF – ANSI 81L); – Overfrequency (OF – ANSI 81H); – Voltage unbalance (VU – ANSI 47); – Differential ground fault (Rc – ANSI 87N); – Reverse active power (RP – ANSI 32R); – Synchrocheck (SC – ANSI 25, optional); – Cyclical direction of phases (ANSI 47); – Power factor (ANSI 78); – Current thresholds; – Power Controller function (optional). L1 L2 L3 3 Differential ground fault (Rc - ANSI 87N): protects against internal earth fault on generator winding. It is required that the toroid hugs the active conductors and the ground conductor. Rc protection is integrated by a dedicated residual current rating plug and the external toroid. ABB catalogue | 1SDC200023D0201 | 3/25 Emax2_cap03.indd 25 15/04/2013 16:46:05 Protection trip units for generators Ekip G Touch The specific functions for generator protections are described below, for each of which it is possible to choose the operating mode: active, only alarm or deactivated. All the voltage and frequency protections also operate when the circuit-breaker is open, enabling the fault to be identified before the closing of the circuit-breaker. t Voltage controlled overcurrent protection (S(V) - ANSI 51V): protection from maximum current with constant trip time (t = k) that is sensitive to the voltage value. The set current threshold, following a voltage drop, decreases by steps or linearly. 1 3 Ks t20 KsxI20 I I20 In step mode (controlled mode) the protection is tripped at the set threshold (I20) if the voltage is above U, whereas it is tripped at the lower threshold of the factor Ks (I20 * Ks) if the voltage is below U. K 1 Ks V UI U On the other hand, in linear mode (restrained mode) two voltage limits are selected within which the protection is tripped at the set threshold (I20) reduced by the factor K corresponding to the measured voltage. The variation of the factor K is proportional to the voltage, and for voltages greater than the upper threshold (Uh) the threshold I20 works, whereas for voltages below the lower threshold (UI) the minimum threshold (I20 * Ks) applies. K 1 Ks UI V Uh 2 V23 V12 α 3 Residual overvoltage (RV – ANSI 59N): with constant trip time (t = k), protects against insulation loss in systems with insulated neutral or with neutral earthed with impedance. α V31 1 3/26 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 26 15/04/2013 16:46:05 Q P Loss of field or reverse reactive power (RQ – ANSI 40 or 32RQ): with constant trip time (t = k), is tripped when the total reactive power absorbed by the generator exceeds the set threshold. It is possible to select the constant threshold (k=0) or a function of the delivered active power of the generator (kz0). TRIP 3 Reactive overpower (OQ – ANSI 32OF): with constant trip time (t = k), the function is tripped when reactive power exceeds the set threshold in the generator to network direction. t Q27 t27 Q Active overpower (OP – ANSI 32OF): with constant trip time (t = k), the function is tripped when the active power exceeds the threshold set in the delivering direction of the generator. t P26 t26 P Active underpower (UP – ANSI 32LF): with constant trip time (t = k), the function is tripped when the active power delivered by the generator is lower than the set threshold. It is possible to disable the protection temporarily, to manage the start-up phase, by setting a time window from the closing of the circuit-breaker, by using an electric signal or via incoming communication to a relay. t P23 t23 P ABB catalogue | 1SDC200023D0201 | 3/27 Emax2_cap03.indd 27 15/04/2013 16:46:05 Protection trip units for generators Ekip G Touch 3 Measurements The Ekip G Touch trip unit provides a complete series of measurements, which are common to Ekip Touch: – Measurements and meters: currents, voltage, power, energy, frequency; – Maximum values and values register; – Data logger; – Information on trip and opening data; – Maintenance indicators. All the information can be viewed directly from the display of the trip-unit, by means of the external Ekip Multimeter display or by Smartphone, Tablet or PC using the front port of the trip unit (with Ekip Bluetooth) or the system communications. Other functions Ekip G Touch provides the same characteristics in terms of user interface, communication, test and power supply described for Ekip Touch equipped with Ekip Measuring Pro. 3/28 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 28 15/04/2013 16:46:05 Protection trip units for generators Ekip G Hi-Touch Characteristics SACE Emax 2’s Ekip G Hi-Touch is the new benchmark for the protection of low voltage electric generators. It provides optimum protection, even in complex installations, due to exclusive functions such as protection against frequency creep and maximum directional current. 3 Ekip G Hi-Touch, like all Hi-Touch trip units, is supplied as standard with the Ekip Measuring Pro measuring and protection module and enables an independent second set of protections to be set. In addition, the Network Analyzer function enables it to monitor the quality of the power delivered by the generator. Ekip G Hi-Touch is available in the LSIG version and ensures all the protection, measuring and control functions of Ekip HiTouch and the specific protections for Ekip G Touch generators. The user interface and the accessories are common to the rest of the family. 2 3 4 5 1 6 1SDC200470F001 1SDC200476F001 7 8 Key: 5. Home pushbutton to return to home page 1. Wide, high resolution touchscreen display 2. Power-on LED indicating correct operation 6. Pushbutton for test and for indicating cause of the trip 3. Pre-alarm LED 7. Test and programming connector 4. Alarm LED 8. Ekip Measuring Pro module with relative poweron LED ABB catalogue | 1SDC200023D0201 | 3/29 Emax2_cap03.indd 29 15/04/2013 16:46:06 Protection trip units for generators Ekip G Hi-Touch 3 Protection functions The Ekip G Hi-Touch trip unit is provided with the following protection functions, common to Ekip Hi-Touch: – Overload (L – ANSI 49); – Time-delayed overcurrent (S – ANSI 51 & 50TD); – Time-delayed overcurrent, second threshold (S2 – ANSI 50TD); – Thermal memory; – Instantaneous overcurrent (I – ANSI 50); – Directional overcurrent (D – ANSI 67); – Voltage controlled overcurrent protection (S(V) – ANSI 51V); – Closing on short circuit (MCR); – Earth fault (G – ANSI 51N & 50NTD); – Second protection against earth fault (ANSI 50GTD/51G & 64REF); – Earth fault on toroid (Gext – ANSI 51G & 50GTD); – Neutral protection; – Start-up function; – Zone selectivity for functions S and G (ANSI 68); – Zone selectivity for directional protection D (ANSI 68) – Start-up function for protection D; – Current unbalance (IU – ANSI 46); – Undervoltage (UV – ANSI 27); – Undervoltage, second threshold (UV2 – ANSI 27); – Overvoltage (OV – ANSI 59); – Overvoltage, second threshold (OV2 – ANSI 59); – Underfrequency (UF – ANSI 81L); – Underfrequency, second threshold (UF2 – ANSI 81L); – Overfrequency (OF – ANSI 81H); – Overfrequency, second threshold (OF2 – ANSI 81H); – Voltage unbalance (VU – ANSI 47); – Residual overvoltage (RV – ANSI 59N); – Differential ground fault (Rc – ANSI 87N); – Loss of field or reverse reactive power (RQ – ANSI 40 or 32R); – Reverse active power (RP – ANSI 32R); – Reactive overpower (OQ – ANSI 32OF); – Active overpower (OP – ANSI 32OF); – Active underpower (UP - ANSI 32LF); – Synchrocheck (SC – ANSI 25, optional); – Cyclical direction of phases (ANSI 47); – Power factor (ANSI 78); – Current thresholds; – Dual setting of protections; – Power Controller function (optional). 3/30 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 30 15/04/2013 16:46:06 In addition, the following protections are also available: f(Hz) Rate of change of frequency (ROCOF – ANSI 81R): enables both positive and negative frequency variations to be detected rapidly. The protection is constant and is tripped when the frequency variation in Hz/s is greater than the set threshold. frequency after failure failure 50/60Hz frequency after failure 3 Time t Second protection against voltage controlled overcurrent protection (S2(V) - ANSI 51V): available in addition to the protection S(V), enables total selectivity to be achieved in all installations. 1 Ks t21 Ks t20 I KsxI20 I20 I21 KsxI21 Q kq kq2 P Second protection against loss of field or reverse reactive power (RQ – ANSI 40 or 32R): enables the generator’s de-energization curve to be followed very accurately, thereby avoiding any unnecessary disconnection. Q25 Q24 Measurements The Ekip G Hi-Touch trip unit provides all the measurements available with Ekip Hi-Touch: – Network Analyzer, in conformity to EN50160 and IEC 61000-4-30; – Measurements and meters: currents, voltage, power, energy, frequency; – Maximum values and values register; – Data logger; – Information on trip and opening data; – Maintenance indicators. Other functions Ekip G Hi-Touch has all the features of Ekip Touch equipped with Ekip Measuring Pro in terms of user interface, communication, test and power supply. ABB catalogue | 1SDC200023D0201 | 3/31 Emax2_cap03.indd 31 15/04/2013 16:46:06 Protection trip units for power control Ekip Power Controller The exclusive Ekip Power Controller function, patented by ABB and available on new SACE Emax 2 circuit-breakers, monitors installation loads and generators, permitting the power consumed to be limited and allowing savings on electricity bills. 3 Ekip Power Controller, which can be used with all Ekip Touch trip units of the Emax 2 series, effectively helps to improve energy efficiency by managing the entire low voltage electrical system. It is, in fact, able to adapt the demand for power according to the availability of the energy source, the time of day and the costs indicated in the current pricing plan. In this way Ekip Power Controller is able to maintain power consumption within the limits defined, thereby optimizing the costs of managing the installation and reducing emissions. Controllable generator Controllable load Non-controllable load Non-controllable generator Control circuit Transformer Energy meter 1SDC200477F001 Emax 2 with Ekip Power Controller 3/32 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 32 15/04/2013 16:46:06 Distinctive features Reduction of energy costs with minimum impact. The loads are disconnected from the power supply for short periods, in the minimum number necessary and in a fixed order of priority, enabling power consumption peaks to be limited. This allows the contract drawn up with the energy provider to be renegotiated, reducing the power allocated, with a consequent reduction in total energy costs. Power limited only when necessary. Ekip Power Controller manages up to four different time bands: it is therefore possible to respect a particular power limit according to whether it is during the day (peak) or night (off peak). In this way, consumption during the day when rates are at their highest can be limited. 3 Simple to install. Ekip Power Controller allows the installation to be managed efficiently with a simple architecture. Thanks to a patented design, it is sufficient to measure the total power of the installation without having to measure the power consumed by each load. Installation costs and times are thereby reduced to a minimum. Ready to use. Ekip Power Controller does not require the writing, implementation and testing of complicated programmes for PLC or computer because the logic has already been implemented in the protection unit and is ready to use; it is sufficient to set the installation parameters from a smartphone or directly from the circuit-breaker display. Improvement of the efficiency of the electrical system. Ekip Power Controller significantly helps to flatten the load curve, limiting the use of peaking power plants in favour of base load power plants with greater efficiency. Graph of daily load Power (kW) 600 Load graph Average P P 15 min 500 P1h 400 300 200 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time Perfect integration into intelligent networks. Thanks to integrated communication modules, Ekip Power Controller can receive the maximum absorbable power directly from the medium voltage control system, determining consumption for the next 15 minutes. Ekip Power Controller, according to the information received, manages the switching off of non-priority loads or the switching on of reserve generators. Ekip Power Controller gives maximum priority to non-programmable preferred energy sources, such as wind and solar, and they are therefore considered uninterruptable. In the event the production of internal power to the controlled network is reduced, due, for example, to decreased production of solar power, Ekip Power Controller will disconnect the necessary loads to respect the consumption limit set. Perfect integration in self-generation systems. This benefit is used, for example, in installations with a system of cogeneration. Ekip Power Controller controls the total consumption drawn from the electrical network, interrupting non-indispensable loads when production is reduced and reconnecting them when generator power is sufficient to not exceed limits. There are multiple advantages: reduction in energy costs, maximum use of local production and greater overall energy efficiency. ABB catalogue | 1SDC200023D0201 | 3/33 Emax2_cap03.indd 33 15/04/2013 16:46:06 Protection trip units for power control Ekip Power Controller Operating principle 3 Ekip Power Controller is an advanced system of control in real time that limits the average power consumed in each time range to a maximum, pre-determined value. This is achieved by delaying, only when necessary, the operation of controllable loads, which are then put back into operation as soon as possible without exceeding the limits of power set. In each instance, Ekip Power Controller optimizes the number of deactivated loads on the basis of a determined order of priority, constantly seeking to supply the most extensive part possible of the installation. If controllable generators are present such as, for example, diesel generators, Ekip Power Controller controls their switching on and off to limit the peak of power consumed. The types of loads that can be interrupted for a few minutes with a limited impact are many and vary according to the application, for example: – industrial ovens, fridges; – ventilation or air compression systems; – electric car charging systems; – electrical air conditioning/heating of corridors, stairways and passageways; – electric kitchens in hotels/hospitals; – swimming pool heating systems and circulation pumps. The method of calculation Ekip Power Controller controls the maximum power consumed by the installation, utilizing the same method as that used for fiscal metering, thereby achieving savings on the component connected to maximum power ($/kW) on electricity bills. The power consumed is calculated by the energy meter as an average value over pre-determined time periods such as, for example, 15 minutes, or even 1 hour. The user therefore pays the same bill both in the event he consumes 1MW continuously (profile 1) or 2MW for 50% of the time and 0MW for the remaining 50% (profile 2), since the average power is the same. Power Profile 2 2MW Profile 1 1MW Average power 0 min 30 min 60 min Time Estimation of consumption Ekip Power Controller uses this principle together with a predictive algorithm that estimates, moment by moment, power at the end of the period in order to decide whether to disconnect or connect loads and generators. This enables brief transient requests for high power to be tolerated, such as, for example, the starting up of motors, without causing the disconnection of loads as soon as the power exceeds the threshold set. The operations of connection and disconnection therefore depend on the consumption from the beginning of the period up to the present moment: for example, if during the first few minutes of the period of reference consumption was very high, Ekip Power Controller will disconnect a greater number of loads in the minutes after; if, on the other hand, the initial consumption was low, it will leave a greater number of loads in operation. 3/34 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 34 15/04/2013 16:46:06 Management of loads According to the consumption estimate at the end of the period, Ekip Power Controller will take different actions: – if the value estimated is greater than the power set as a target, Ekip Power Controller makes the decision to disconnect one of the loads controlled from the power supply, or to connect a generator; – if the value estimated is equal or slightly less than the average power set as a target, Ekip Power Controller makes the decision to leave the conditions of the controlled loads and generators unchanged; – if the value estimated is significantly lower than the average power set as a target, Ekip Power Controller makes the decision to reconnect one of the loads controlled to the power supply, or switch off a generator if one or more of these have been switched on previously. This operation is carried out cyclically each time by calculating a new estimate: therefore, if the estimate of power consumed continues to be too high despite the fact that a load has been disconnected, Ekip Power Controller will proceed to disconnect another and so on, until the power limit is respected. In this way, the number of connected or disconnected loads varies dynamically, and always with the guarantee that only the minimum number needed to respect the power limit are disconnected. 3 Priority of loads If the decision made is to disconnect or re-connect one of the loads controlled, Ekip Power Controller proceeds according to an established order: the load indicated as the first will be that of least importance, or that for which a temporary period of deactivation is acceptable; the load indicated as the second will be the next one in order of importance, and so on. The loads that have been disconnected in that order will be later re-connected in the reverse order, beginning with the load that is most important for the installation. In this way, the impact on the production process can be minimized, limiting the disconnection time for loads of the highest priority. Furthermore, by gradually connecting and disconnecting the loads in order of priority, voltage imbalances and consumption peaks affecting the network are avoided. Protection of the installation Ekip Power Controller can be integrated perfectly into the installation’s protection devices. In fact, if one of the controlled circuit-breakers opens due to an overcurrent or by manual operation, Ekip Power Controller considers the load unavailable until the operator resets it, making it available again. In this way, safe operation of the installation is always guaranteed. ABB catalogue | 1SDC200023D0201 | 3/35 Emax2_cap03.indd 35 15/04/2013 16:46:06 Protection trip units for power control Ekip Power Controller Architecture 3 Ekip Power Controller is installed on the main low voltage circuit-breaker, immediately downstream of the transformer and energy meter. By using the high precision current and voltage sensors located inside the SACE Emax 2, it is able to measure the average power consumed by the installation, using the same method as that used for fiscal metering, over an established time period. To control this average power, Ekip Power Controller performs controlled opening and closing of the switching devices. A Power Controller system consists of: – a SACE Emax 2 circuit-breaker with Ekip Touch protection trip unit equipped with Ekip Power Controller and Ekip Measuring. This circuit-breaker is the power controller and meterand implements the Power Controller function, determining the connection and disconnection of loads; – up to 15 controlled loads and/or generators. The connection between Ekip Power Controller and users can be achieved: - with Ekip Signalling modules for connections inside the same switchboard. This allows circuit-breakers or contactors installed on the power circuit to be commanded directly through available outputs. The opening and closing operations are always carried out in safety thanks to an input that receives feedback on the state of the device. - with Ekip Signalling modules by acting on the generator starting circuit or on the control circuit of the loads. This allows, for example, the consumption of motors powered by drives to be reduced without interrupting the production cycle. - with Ekip Link communication modules for installations with circuit-breakers in different switchboards. This enables wiring between switchboards to be simplified to the use of only one EtherNet cable. 09%UHDNHU (QHUJ\0HWHU (NLS6XSSO\ NPRGXOH NPRGXOH (NLS/LQN (QHUJ\PHWHUFORFN NPRGXOH (NLSSRZHU&RQWUROOHU (NLS7RXFK ;702(( 4 6< 4 6< 70 70 1R3ULRULW\ORDGV 1R3ULRULW\ORDGV 0 1R3ULRULW\ORDGV $FWXDWRU <2 <& (NLS6XSSO\ (NLS7RXFK 0 1R3ULRULW\ORDGV $FWXDWRU <2 <& (NLS'LS 0 $FWXDWRU <2 <& 1SDC200479F001 ;702(( (NLS/LQN (NLS/LQN 9$& 9$& (NLS6XSSO\ (NLS/LQN 9$& 3ULRULW\ORDGV In the event that the installation is constructed with a single medium voltage delivery point and two or more transformers in parallel, Ekip Power Controller can acquire, via Ekip Link, the power measurement carried out by the other Emax 2 devices present. In this way the power limit can be respected at the medium voltage measuring point, without having to duplicate the control circuit of the loads. 3/36 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 36 15/04/2013 16:46:07 Installation Ekip Power Controller is not only simple to implement and use, it is also very flexible thanks to parameters which have been specially developed to satisfy the needs of all applications. Installation parameters: – Power limit: this is the average power that Ekip Power Controller respects, which can be selected in kW directly from the display. – Evaluation window: this is the period in which the distributor of electrical energy evaluates the maximum power, which can be selected within a wide range to respect the local needs of each country. – Synchronization input: this is used to synchronize the clock inside Ekip with that of the meter. It can also be used to signal a change in band. 3 Parameters of the user: – Type of user: can be selected from among load and generator. – Minimum disconnection time (T off min): this is the minimum time for which a load or generator is not supplied with power following disconnection. This is useful when you wish to avoid frequent operations on users that are at the top of the priority list. Ekip Power Controller reconnects the load or generator only after the time set has passed. – Maximum disconnection time (T off max): this is the maximum time for which no power is permitted. It is required, for example, in the case of an oven to keep the temperature within the established limits. When the time has passed, Ekip Power Controller reactivates it automatically, disconnecting, if necessary, a load of a higher priority. – Minimum connection time (T on min): minimum time for which a load or generator is kept powered following reconnection. It is useful in the event the generator has a minimum time for which it must remain connected. Until the time set has passed, Ekip Power Controller will not disconnect the load, connecting, if necessary, loads of a higher priority. – Time window: this is the hours in the day when a load or generator can be operated. It is useful, for example, in the case of a canteen that cannot be disconnected during meal times, or a diesel generator that can not be operated at night due to noise pollution. – Temporary unavailability: a user can be temporarily deactivated, for example, because it is undergoing maintenance, through the circuit-breaker display or digital input connected to a manual/automatic selector. The digital input can also be used, for example, in the case of a fridge, to manage its interruptability: with active input the fridge cannot be disconnected as it is above the minimum temperature, with inactive input, on the other hand, it can be disconnected. Power limit can be set directly in kW Time bands up to 4 Synchronization with contactor • Evaluation time 5…120 min Number of loads/generators up to 15 Priority from 1 to 15 t on min 1…360 min t off min 1…360 min t off max 1…360 min Temporary disabling input 1 for each device Controllable devices load/generator Type of control - moulded-case and air circuit-breaker - modular circuit-breakers - contactors - control circuit of load/generator Type of connections - wired - with Ekip Link communication for ACB ABB catalogue | 1SDC200023D0201 | 3/37 Emax2_cap03.indd 37 15/04/2013 16:46:07 Technical characteristics for protection trip units Protection functions ABB Code ANSI/IEEE C37.2 Function Code Threshold L 49 I1 = 0.4 - 0.42 - 0.45 - 0.47 - 0.5 - 0.52 - 0.55 - 0.57 - 0.6 - 0.62 - 0.65 - 0.67 - 0.7 0.72 - 0.75 - 0.77 - 0.8 - 0.82 - 0.85 - 0.87 - 0.9 - 0.92 - 0.95 - 0.97 - 1 x In Overload protection 3 Thermal memory S 51 Tolerance tripping between 1.05 and 1.2 x I1 Short-circuit selective protection I2 = 0.6 - 0.8 - 1 - 1.5 - 2 - 2.5 - 3 - 3.5 - 4 - 5 - 6 - 7 - 8 - 9 - 10 x In Tolerance ± 7% If d 6 x In ± 10% If > 6 x In Short-circuit selective protection I2 = 0.6 - 0.8 - 1 - 1.5 - 2 - 2.5 - 3 - 3.5 - 4 - 5 - 6 - 7 - 8 - 9 - 10 x In Thermal memory ± 7% If d 6 x In ± 10% If > 6 x In Tolerance I G 50 51N Short-circuit instantaneous protection I3= 1.5 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 x In Tolerance ± 10% Earth fault protection I4(1) = 0.1 - 0.2 - 0.3 - 0.4 - 0.6 - 0.8 - 1 x In Tolerance ± 7% Earth fault protection I4(1) = 0.1 - 0.2 - 0.3 - 0.4 - 0.6 - 0.8 - 1 x In Tolerance ± 7% (1) G protection below 100A or below 0.2 In available with auxiliary supply (2) The minimum trip time is 1s, regardless of the type of curve set (self-protection) The tollerances above apply to trip units already powered by the main circuit with current flowing in at least two-phases or an auxiliary power supply. In all other cases the following tollerance values apply ABB Code Trip threshold L Trip time Trip between 1.05 and 1.2 x I1 ± 20% S ± 10% ± 20% I ± 15% d 60ms G ± 15% ± 20% 3/38 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 38 15/04/2013 16:46:07 Trip time Excludibility Pre Alarm Trip curve with I = 3 I1, t1 = 3 - 12 - 24 - 36 - 48 - 72 - 108 - 144 s (2) No 50 ... 90 I1 Step 1% t = k / I2 Yes No t=k Yes No t = k / I2 Yes No Yes No t=k Yes No t=k Yes No t = k / I2 Ekip Dip 3 Yes ± 10% If d 6 x In ± 20% If > 6 x In t2 = 0.1 - 0.2 - 0.3 - 0.4 - 0.5 - 0.6 - 0.7 - 0.8s The better of the two data: ± 10% or ± 40 ms with I = 10 In, t2 = 0.1 - 0.2 - 0.3 - 0.4 - 0.5 - 0.6 - 0.7 - 0.8s ± 15% If d 6 x In ± 20% If > 6 x In Instantaneous d 30 ms t4 = 0.1 - 0.2 - 0.4 - 0.8s The better of the two data: ± 10% or ± 40 ms t4 = 0.1 - 0.2 - 0.4 - 0.8s ± 15% ABB catalogue | 1SDC200023D0201 | 3/39 Emax2_cap03.indd 39 15/04/2013 16:46:07 Technical characteristics for protection trip units Protection functions ABB Code ANSI Code Function Thereshold Threshold step Tripping time Time Step L 49 Overload Protection I1 = 0.4…1 x In 0.001 x In with I = 3 I1, t1 = 3...144 s 1s Thermal Memory 3 Tolerance tripping between 1.05 and 1.2 x I1 Overload Protection I1 = 0.4…1 x In Tolerance tripping between 1.05 and 1.2 x I1 50TD Time-delayed overcurrent protection I2 = 0.6...10 x In 68 Zone selectivity 49 S 51 Start up Activation: 0.1…10 x In Tolerance ± 7% I d 6 x In ± 10% I > 6 x In Time-delayed overcurrent protection I2 = 0.6...10 x In ± 10% I d 6 x In ± 20% I > 6 x In 0.001 x In with I = 3 I1, t1 = 3...144 s Standard inverse SI: k=0.14 D=0,02 Very Inverse VI: k=13.5 D=1 Extremely Inverse EI: k=80 D=2 t=k/I4: k=80 D=4 1s ± 10% I d 6 x In ± 20% I > 6 x In 0.1 x In 0.1 x In t2 = 0.05...0.8s 0.01s t2sel = 0.04…0.2s 0.01s Range: 0.1…30s 0.01s The better of the two data: ± 10% or ± 40 ms 0.1 x In with I = 10 In, t2 = 0.05...0.8s 0.01s Thermal Memory Tolerance S2 S(V) 50TD 51V 51V I5 = 0.6...10 x In 0.1 x In t5 = 0.05...0.8s 0.01s Start up Activation: 0.1…10 x In 0.1 x In Range: 0.1…30s 0.01s Tolerance ± 7% I5 d 6 x In ± 10% I5 > 6 x In Voltage controlled overcurrent protection I20 = 0.6...10 x In 0.1 x In Step mode (controlled mode) Ul= 0.2…1 x Un 0.01 x Un Ks= 0.1…1 0.01 MCR Ul= 0.2…1 x Un 0.01 x Un Uh= 0.2…1 x Un 0.01 x Un Ks= 0.1…1 0.01 ± 10% Voltage controlled overcurrent protection I21 = 0.6...10 x In 0.1 x In Step mode (controlled mode) Ul2= 0.2…1 x Un 0.01 x Un Ks2= 0.1…1 0.01 Tolerance 50 The better of the two data: ± 10% or ± 40 ms Tolerance Linear mode (restrianed mode) I ± 15% I d 6 x In ± 20% I > 6 x In Time-delayed overcurrent protection Linear mode (restrianed mode) S2(V) ± 7% I2 d 6 x In ± 10% I2 > 6 x In t20 = 0.05…30s 0.01s The better of the two data: ± 10% or ± 40 ms Ul2= 0.2…1 x Un 0.01 x Un Uh2= 0.2…1 x Un 0.01 x Un Ks2= 0.1…1 0.01 ± 10% t21 = 0.05…30s 0.01s The better of the two data: ± 10% or ± 40 ms Istantaneous overcurrent protection I3= 1.5...15 x In 0.1 x In Instantaneous - Start up Activation: 0.1…10 x In 0.1 x In Range: 0.1…30s 0.01s Tolerance ± 10% Closing on short-circuit protection I3= 1.5...15 x In Tolerance ± 10% d 30 ms 0.1 x In Instantaneous Activation range: 40…500ms 0.01s d 30 ms 3/40 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 40 15/04/2013 16:46:07 Excludibility Excludibility trip Pre-allarm yes, with rating plug L=off no 50...90% I1 Trip curve Ekip Touch Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch t = k / I2 ● ● ● ● ● ● ● ● ● ● ● ● yes yes, with rating plug L=off no 50...90% I1 yes no yes t1 ß t=k ● ● ● ● yes ● ● ● ● yes ● ● ● ● ● ● ● ● ● ● ● ● yes yes no t = k / I2 yes yes yes no t=k yes yes yes yes yes no no ● ● ● ● t=k ● ● ● ● ● ● t=k 3 ● ● ● yes no no t=k yes yes no no t=k ● ● ● ● ● ● ● ● ● ● ● ● Table continued on next page ABB catalogue | 1SDC200023D0201 | 3/41 Emax2_cap03.indd 41 15/04/2013 16:46:08 Technical characteristics for protection trip units Protection functions ABB Code ANSI Code Function Thereshold Threshold step Tripping time Time Step G 50N TD Earth fault protection I4(1) = 0.1...1 x In 0.001 x In with I > I4, t4 = 0.1…1s 0.05s 68 Zone selectivity t4sel = 0.04…0,2s 0.01s Start up Activation: 0.1…10 x In 0.1 x In range: 0.1…30s 0.01s Tolerance ± 7% Earth fault protection I4(1) = 0.1...1 x In Tolerance ± 7% Earth fault protection I4(1) = 0.1...1 x In Toroid 0.001 x In Toroid t4 = 0.1…1s 0.05s Start up Activation: 0.1…10 x In 0.1 x In 0.01s Tolerance ± 7% Earth fault protection I4(1) = 0.1...1 x In Tolerance ± 7% 67 Directional overcurrent protection I7 = 0.6...10 x In 68 Zone selectivity 3 51N Gext 50G TD 51G D IU 46 Rc 64 50N TD 87N UV 27 UV2 OV OV2 RV VU UF UF2 OF 27 59 59 59N 47 81L 81L 81H The better of the two data: ± 10% or ± 40 ms 0.001 x In with I = 4 In, t4 = 0.1…1s ± 15% range: 0.1…30s The better of the two data: ± 10% or ± 40 ms 0.001 x In with I = 4 In, t4 = 0.1…1s 0.1 x In 0.01s 0.01s range: 0.1…30s 0.01s Activation: 0.1…10 x In ± 7% I7 d 6 x In ± 10% I7 > 6 x In Current unbalance protection I6= 2…90% In unbalance Tolerance ± 10% The better of the two data: ± 10% or ± 40 ms Residual current protection Differential ground fault protection I'n= 3 - 5 - 7 - 10 - 20 - 30A t'n = 0.06 - 0.1 - 0.2 0.3 - 0.4 - 0.5 - 0.8s Tolerance - 20% ÷ 0% Undervoltage Protection U8= 0.5….0.98 x Un Tolerance ± 5% Undervoltage Protection U15= 0.5….0.98 x Un Tolerance ± 5% Overvoltage protection U9= 1.02….1.5 x Un Tolerance ± 5% Overvoltage protection U16= 1.02….1.5 x Un Tolerance ± 5% Residual overvoltage protection U22= 0.1….0.5 x Un Tolerance ± 5% U14= 2…90% Un unbalance ± 10% Underfrequency protection f12= 0.9….0.99 x fn Tolerance ± 5% Underfrequency protection f17= 0.9….0.99 x fn Tolerance ± 5% Overfrequency protection f13= 1.01….1.1 x fn Tolerance ± 5% 0.1 x In t7 = 0.2...0.8s t7sel = 0.13…0.5s Tolerance Tolerance 0.01s ± 15% Start up Voltage unbalance protection 0.01s The better of the two data: ± 10% or ± 40 ms 1%In t6 = 0.5…60s 0.5s 0.06s 0.001 x Un t8 = 0.05…60s 0.05s The better of the two data: ± 10% or ± 40 ms 0.001 x Un t15 = 0.05…60s 0.05s The better of the two data: ± 10% or ± 40 ms 0.001 x Un t9 = 0.05…60s 0.05s The better of the two data: ± 10% or ± 40 ms 0.001 x Un t16 = 0.05…60s 0.05s The better of the two data: ± 10% or ± 40 ms 0.001 x Un t22 = 0.5…60s 0.05s The better of the two data: ± 10% or ± 40 ms 1%Un t14 = 0.5…60s 0.5s The better of the two data: ± 10% or ± 40 ms 0.01 x fn t12 = 0.2…60s 0.1s The better of the two data: ± 10% or ± 40 ms 0.01 x fn t17 = 0.2…60s 0.1s The better of the two data: ± 10% or ± 40 ms 0.01 x fn t13 = 0.5…60s 0.1s The better of the two data: ± 10% or ± 40 ms 3/42 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 42 15/04/2013 16:46:08 Excludibility Excludibility trip Pre-allarm Trip curve Ekip Touch Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch yes yes t=k ● ● ● ● yes ● ● ● ● yes ● ● ● ● 90% I4 yes yes 90% I4 t = k / I2 ● ● ● ● yes yes 90% I4 t=k ● ● ● ● ● ● ● ● ● ● ● ● yes yes yes 90% I4 t = k / I2 yes yes no t=k ● ● yes ● ● yes ● ● yes yes no t=k ● ● ● ● Attivabile with rating plug Rc no no t=k ● ● ● ● yes yes no t=k ● ● ● yes yes no t=k ● yes yes no t=k ● yes yes no t=k ● yes yes no t=k yes yes no t=k yes yes no yes yes yes yes 3 ● ● ● ● ● ● ● ● ● t=k ● ● ● no t=k ● no t=k ● ● ● ● Table continued on next page ABB catalogue | 1SDC200023D0201 | 3/43 Emax2_cap03.indd 43 15/04/2013 16:46:09 Technical characteristics for protection trip units Protection functions ABB Code ANSI Code Function Thereshold Threshold step Tripping time Time Step OF2 81H Overfrequency protection f18= 1.01….1.1 x fn 0.01 x fn t18 = 0.5…60s 0.1s Tolerance ± 5% Rate of change of frequency protection f28= 0.4….10 Hz/s Tolerance ± 10% 3 ROCOF RP RQ 81R 32R 40/32R Reverse active power protection P11= -1…-0.08 Sn Tolerance ± 10% Loss of field or reverse reactive power protection Q24= -1…-0.1 Sn Kq= -2…2 Loss of field or reverse reactive power protection Q25= -1…-0.1 Sn Kq2= -2…2 OP OQ UP 32OF 32OF 32LF Tolerance ± 10% Active overpower protection P26= 0.4…2 Sn Tolerance ± 10% Reactive overpower protection Q27= 0.4…2 Sn Tolerance ± 10% Active underpower protection P23 = 0.1...1 x In The better of the two data: ± 10% or ± 40 ms 0.2 Hz/s The better of the two data: ± 10% or ± 40 ms 0.001 Sn Synchrocheck 25 SC ± 10% Synchrocheck (Live busbars) Ulive= 0.5…1.1 Un 'U= 0.02…0.12 Un 'f= 0.1…1Hz ')= 5…50° elt tsyn= 0.1…3s Tolerance ± 10% Synchrocheck (Live,Dead busbars) Ulive= 0.5…1.1 Un Udead= 0.02…0.2 Un t11 = 0.5…100s 0.1s The better of the two data: ± 10% or ± 40 ms 0.001 Sn t24 = 0.5…100s 0.1s t24 = 0.5…100s 0.1s 0.01 0.001 Sn 0.01 The better of the two data: ± 10% or ± 40 ms 0.001 Sn t26 = 0.5…100s 0.5s The better of the two data: ± 10% or ± 40 ms 0.001 Sn t27 = 0.5…100s 0.5s The better of the two data: ± 10% or ± 40 ms 0.001 x Sn Temporary deactivation Tolerance with f > f28 0.1s t28 = 0.4...10s with f28=0.4...1.0 Hz/s t28 = 0.25...10s with f28=1.2...5.0 Hz/s t28 = 0.15...10s with f28> 5.2 Hz/s t23 = 0.5…100s 0.5s range from closing: 0.1…30s o with digital input 0.1s The better of the two data: ± 10% or ± 40 ms 0.01 Un 0.01 Un 0.1Hz 5° elt 0.1s tref= 0.1…30s 0.1s 0.01 Un 0.01 Un tref= 0.1…30s 0.1s Tolerance ± 10% 47 Cyclical direction of the phases 1-2-3 or 3-2-1 78 3phase Power factor PF3= 0.2…0,95 0.01 Current thereshold LC1=50%...100% I1 LC2=50%...100% I1 Iw= 0.3…10 In 1% 1% 0.01 x In Tolerance ± 10% 1) G protection below 100A or 0.2 x In available with auxiliary supply. The tollerances above apply to trip units already powered by the main circuit with current flowing in at least two-phases or an auxiliary power supply. In all other cases the following tollerance values apply: ABB Code Trip threshold L Trip between 1.05 and 1.2 x I1 Trip time ± 20% S ± 10% ± 20% I ± 15% d 60ms G ± 15% ± 20% Other protection ± 15% ± 20% 3/44 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 44 15/04/2013 16:46:10 Excludibility Excludibility trip Pre-allarm Trip curve yes yes no t=k yes yes no t=k yes yes no t=k yes yes no t=k yes yes no t=k yes yes no t=k ● ● yes yes no t=k ● ● yes yes no t=k ● ● yes only signalling no - yes only signalling no - yes only signalling no - ● ● ● yes only signalling no - ● ● ● yes only signalling no - ● ● ● Ekip Touch Ekip Hi-Touch Ekip G Touch ● Ekip G Hi-Touch ● 3 ● ● ● ● ● ● ● ● yes ● Key: not available available available with Ekip Measuring Pro available with Ekip Synchrocheck ABB catalogue | 1SDC200023D0201 | 3/45 Emax2_cap03.indd 45 15/04/2013 16:46:11 Technical characteristics for protection trip units Measurement functions Instantaneous measurements 3 Displayed with Ekip Multimeter Parameters Currents (RMS) [A] • I1, I2, I3, neutral Earth fault current (RMS) [A] • Ig [A] • I1, I2, I3, neutral • eg. L, S, I, G Parameters Record of values: of the parameter for each interval with time-stamping Current: minimum and maximum Parameters Information on trip and opening data: after a fault with or without auxiliary supply Type of protection tripped Fault values per phase [A] Time-stamping • eg. I1, I2, I3, neutral for S protection • Date, time and progressive number Maintenance indicators Parameters Information on last 30 trips • Type of protection, fault values and time-stamping Information on last 200 events • Type of event, time-stamping Can be associated to alarm Number of mechanical operations (1) [no] • Total number of trips [no] • Total operating time [h] • Wear of contacts [%] • Prealarm >80%, Alarm = 100% Date of maintenance operations performed • Last Indication of maintenance operation needed • Circuit-breaker I.D. • Self-diagnosis Type of circuit-breaker, assigned device name, serial number Parameters Check of continuity of internal connnections • Alarm due to disconnection: rating plug, sensors, trip coil Failure of circuit-breaker to open (ANSI 50BF) • Alarm following non-tripping of protection functions Temperature (OT) • Pre-alarm and alarm for abnormal temperature (1) with auxiliary supply present 3/46 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 46 15/04/2013 16:46:11 Precision Standard di riferimento 1% Class 1 IEC 61557-12 Ekip Dip 3 2% Window Intervals Fixed, synchronizable by remote Duration: 5…120min Number of intervals: 24 Note: Opening of circuit-breaker can be set in the event of alarm ABB catalogue | 1SDC200023D0201 | 3/47 Emax2_cap03.indd 47 15/04/2013 16:46:11 Technical characteristics for protection trip units Measurement functions Instantaneous measurements 3 Parameters Currents (RMS) [A] I1, I2, I3, neutral Earth fault current (RMS) [A] Ig Phase-phase voltage (RMS) [V] V12, V23, V31 Phase-neutral voltage (RMS) [V] V1n, V2n, V3n Frequency [Hz] f Active power [kW] P1, P2, P3, Ptot Reactive power [kVAR] Q1, Q2, Q3, Qtot Apparent power [KVA] S1, S2, S3, Stot Phase sequence Power factor PF1, PF2, PF3, PF total Peak factor total Parameters Counters recorded from installation or from the last reset Active energy [kWh] Ep total, Ep absorbed, Ep consumed Reactive energy [kVARh] Eq total, Ep absorbed, Ep consumed Apparent energy [KVAh] Es total Network Analyzer Parameters Hourly average voltage value [V] [no] - Umin= 0.75…0.95 x Un - Umax= 1.05…1.25 x Un - Events counter (nr. of events day by day in the last year plus the total events in the breaker's lifetime) Short voltage interruptions [no] - Umin= 0.75…0.95 x Un - Events counter (nr. of events day by day in the last year plus the total events in the breaker's lifetime) Short voltage spikes [no] - Umax= 1,05…1,25 x Un - Events counter (nr. of events day by day in the last year plus the total events in the breaker's lifetime) Slow voltage sags and swells [no] - Umin1= 0.75…0.95 x Un - Umin2= 0.75…0.95 x Un - Umin3= 0.75…0.95 x Un - Umax1= 1.05…1.25 x Un - Umax2= 1.05…1.25 x Un - Events counter (nr. of events day by day in the last year plus the total events in the breaker's lifetime) Voltage unbalance [V] [no] - U neg. seq.= 0.02…0.10 x Un - Events counter (nr. of events day by day in the last year plus the total events in the breaker's lifetime) Harmonic analysis Current and Voltage - up to 50° - Alarm THD: 5…20% - Single harmonic alarm: 3...10% plus a count of minutes the harmonic has been exceeded 3/48 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 48 15/04/2013 16:46:11 Precision Ekip Touch Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch 1% 2% 3 0.5% 0.5% 0.2% 2% 2% 2% 2% Precision 2% 2% 2% Intervals t = 5…120min - - t <40ms - - t <40ms - - t = 0.04ms...60s - - t = 5…120min - - - - ABB catalogue | 1SDC200023D0201 | 3/49 Emax2_cap03.indd 49 15/04/2013 16:46:12 Technical characteristics for protection trip units Measurement functions Parameters Record of values: of the parameter for each interval with time-stamping 3 Current: minimum and maximum [A] I1, I2, I3, neutral Phase-phase voltage: minimum and maximum [V] V12, V23, V31 Active power: average and maximum [kW] Ptot Reactive power: average and maximum [kVAR] Qtot Apparent power: average and maximum [KVA] Stot Parameters Data logger: record of high sampling rate parameters Currents [A] Voltages [V] I1, I2, I3, neutral, Ig U12, U23, U31 Sampling rate [Hz] 1200-9600 Maximum recording duration [s] 18 Recording stop delay [s] 0-10s Number of registers [no] 2 independent Information on trip and opening data: after a fault without auxiliary supply Parameters Type of protection tripped eg. L, S, I, G, UV, OV Fault values per phase [A/V/Hz w/VAR] eg. I1, I2, I3, neutral for S protection V12, V23, V32 for UV protection Time-stamping Date, time and progressive number Maintenance indicators Parameters Information on last 30 trips Type of protection, fault values and time-stamping Type of event, time-stamping Information on last 200 events Number of mechanical operations (1) [no] Total number of trips [no] Total operating time [h] Wear of contacts [%] Date of maintenance operations performed Can be associated to alarm Prealarm >80% Alarm = 100% Last Indication of maintenance operation needed Circuit-breaker I.D. Type of circuit-breaker, assigned device name, serial number Self-diagnosis Parameters Check of continuity of internal connnections Alarm due to disconnection: rating plug, sensors, trip coil Failure of circuit-breaker to open (ANSI 50BF) Alarm following non-tripping of protection functions Temperature (OT) Prealarm and alarm for abnormal temperature (1) with auxiliary supply present 3/50 | 1SDC200023D0201 | ABB catalogue Emax2_cap03.indd 50 15/04/2013 16:46:12 Window Intervals Fixed synchronizable by remote Duration: 5…120min Number of intervals: 24 Ekip Touch Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch 3 Note: Opening of circuit-breaker can be set in the event of alarm Key: not available available available with Ekip Measuring Pro ABB catalogue | 1SDC200023D0201 | 3/51 Emax2_cap03.indd 51 15/04/2013 16:46:13 Emax2_cap03.indd 52 15/04/2013 16:46:13 Communication devices and systems Introduction 4/2 Supervision and control Supervision of the switchgear compartment 4/4 Supervision of the electrical switchgear 4/6 Supervision of the electrical installation 4/8 Software Ekip Connect 4/10 Ekip View 4/12 Ekip T&P Interface 4/14 4 ABB Catalogue | 1SDC200023D0201 | 4/1 Emax2_cap04.indd 1 12/04/2013 13:58:12 Communication devices and systems Introduction SACE Emax 2 circuit-breakers provide a complete and flexible offering that can be adapted to the actual level of supervision and control required. The rapid spread of systems for the supervision and control of low voltage electrical distribution plants is determined by the growing need to: - optimize energy efficiency by analyzing energy consumption; - ensure service continuity, minimizing the time needed to identify and rectify faults; - guarantee efficient planning of maintenance activities. 4 Typical sector Industrial Hospital Level of supervision and control in low voltage systems Switchgear compartment Sulution with SACE Emax 2 - Ekip Touch trip units with high resolution display OEMs Naval - Ekip trip units - Ekip Multimeter display on the front of switchgear Benefit of the ABB solution - simple and intuitive use - reduced dimensions - does not require an auxiliary power supply for safety - flexible installation - simultaneous reading of various electrical values 4/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 2 12/04/2013 13:58:13 According to their complexity, the supervision of low voltage systems may involve different levels: - switchgear compartment: for the control of the main electrical values of the circuit-breaker. It provides a general but precise indication of the level of absorption of the system (main circuit-breaker) and the individual utilities (outgoing feeder circuit-breakers). - electrical switchgear: to display the data of all circuit-breakers installed in the switchgear from a single point: in local mode via the operator panel on the front of the switchgear, or remotely via an Internet connection. - electrical system: to manage complex systems in which devices must be integrated with automated industrial processes or in intelligent electrical networks, better known as smart grids. 4 Industries of medium dimensions Shopping centres Office buildings Oil & gas Automated industrial processes Data centers Electrical switchgear Electrical installation - Ekip trip units - Ekip Touch trip units - Ekip link modules - Ekip com communication modules - Ekip Control Panel operator panel colour touch screen - Ekip View supervision software Smart grids - Standardized EtherNet components - centralized control from front of switchgear - wide range of protocols supported - access via web to the installation - installation times reduced to a minimum - rapid installation - redundancy of communication - ease of use - ready to smart grid circuit-breakers - system ready to use - complete network supervision ABB Catalogue | 1SDC200023D0201 | 4/3 Emax2_cap04.indd 3 12/04/2013 13:58:14 Communication devices and systems Supervision of the switchgear compartment The SACE Emax 2 circuit-breakers equipped with Ekip electronic trip units enable electrical measurements and diagnostic data to be displayed on the front of the switchgear. Ekip Multimeter 1SDC200491F001 Ekip Touch 1SDC200492F001 4 Solution with Ekip Touch trip units The Ekip Touch electronic trip units are, therefore, the ideal solution for supervision and control of the compartments in switchgear. In particular: - their use is simple and intuitive thanks to a large, high resolution, colour touch screen; - they do not require an auxiliary power supply for safety; the Ekip Touch trip units are directly supplied by the current sensors integrated in the circuit-breaker, thereby avoiding the use of external power supplies. For the list of information available for each trip unit, consult chapter 3. 4/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 4 12/04/2013 13:58:15 Solution with Ekip Multimeter Display on switchgear front The Ekip Multimeter is a display unit to be installed on the front of the switchgear for SACE Emax 2 air circuit-breakers equipped with Ekip electronic trip units. This device remotely displays the information about the system that is available in the trip unit to which it is connected. The main characteristics of the Ekip Multimeter unit are: - Graphical and functional uniformity with the Ekip Touch trip units; Ekip Multimeter uses the same display as the trip unit to which it is connected, ensuring perfect continuity between the graphic display and the menu items. - Reduced dimensions; the Ekip Multimeter guarantees the precision of the trip unit to which it is connected and performs the function of a measuring instrument without requiring the installation of external current and voltage transformers. - Flexible installation; the Ekip Multimeter can be installed up to distance from the trip unit, enabling access to information from the most convenient point. - Simultaneous reading of the various electrical values; the advanced connection system used allows several Ekip Multimeter devices to be connected to the same protection trip unit. Furthermore, if connected to trip units equipped with display, the Ekip Multimeter enables adjustment of the parameters and protection thresholds. 4 Supervision of switchgear compartment Electronic trip unit Ekip Dip Ekip Touch Solution Ekip trip units + Ekip Multimeter Type of trip units connectable to Ekip Multimeter Ekip trip units Number of trip units connectable to Ekip Multimeter 1 Ekip Touch + Ekip measuring module Ekip Hi Touch Ekip G Touch Ekip Hi-G Touch Measurement functions Currents • • • • Voltages - - • • Powers - - • • Energies - - • • Harmonics - - - • Network analyzer - - - • Setting of thresholds - • • • Setting of thresholds sacond set - - - • Resetting of alarms • • • • Protection function alarms • • • • Device alarms • • • • Protection unit tripping details • • • • Events log • • • • Protection unit tripping log • • • • Number of operations • • • • Number of trips • • • • Wear of contacts • • • • Adjustment functions Diagnostics Maintenance Other data Status of circuit-breaker Circuit-breaker position 1) Local/remote mode • • • • • • • • • • • • 1) Circuit-breakers equipped with auxiliary contacts to indicate position ABB Catalogue | 1SDC200023D0201 | 4/5 Emax2_cap04.indd 5 12/04/2013 13:58:15 Communication devices and systems Supervision of the electrical switchgear Ekip Link is a flexible and efficient solution for controlling and supervising low voltage electrical switchgear; it is a system that enables SACE Emax 2 circuitbreakers to be connected to the Ekip Control Panel operator panel by means of Ekip Link interface modules. 4 Ekip Link system The main characteristics of the Ekip Link System are: - centralized control; from the Ekip Control Panel operator panel, all the main values of the installation (electrical measurements, system diagnostics, trends…) can be displayed, and all circuit-breakers connected directly to the front of the switchgear can be inspected. - adaptation to real requirements; when the electrical values to be monitored are limited to currents only, the Ekip Dip trip unit can be connected to the Ekip Link without having to use circuit-breakers equipped with communication modules. - access via the Internet to the installation by any Internet browser using the web server function performed by the Ekip Control Panel. - rapid installation, through the use of standardized EtherNet components such as STP cables and RJ45 type connectors. - ease of use; thanks to the Ekip Control Panel operator panel in front of the switchgear with colour touch screen, the system mimic panel can be displayed so that the entire installation can be controlled rapidly and intuitively. - ready to use; Ekip Control Panel is supplied with pre-configured software that requires no programming. It is only necessary to start scanning the Ekip Link system from the operator panel and in a few seconds communication with the connected devices is active. 1SDC200493F001 Ekip Link enables supervision of electrical switchgear on which up to 30 ABB SACE circuit-breakers have been installed. Tmax T and Tmax XT series circuit-breakers equipped with Modbus RTU communication can also be easily integrated into the Ekip Link system using the multi-serial port fitted on the Ekip Control Panel. 4/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 6 12/04/2013 13:58:17 Supervision of switchgear compartment Electronic trip unit Ekip Dip Ekip Touch Ekip Touch + Ekip measuring module Ekip Hi Touch Solution Ekip protection trip units equipped with Ekip link module + Ekip Control Panel operator panel + standard EtherNet components Ekip G Touch Ekip Hi-G Touch Type of trip units connectable Ekip protection trip units Number of trip units connectable to the Ekip link system up to 30 Data exchange rate of Ekip link system 100 Mbit/sec 1) Supervision and control functions Opening and Closing of circuit-breakers 2) 4 • Electrical value trends I I I,V,P I,V,P Log of electrical value trends I I I,V,P I,V,P Dynamic installation mimic panel • Automatic scanning of the Ekip link system • Centralized synchronizing of time • Web server function • 3) Measurement functions Currents • • • • Voltages - - • • Powers - - • • Energies - - • • Harmonics - - - • Network analyzer - - - • Data logger - • • • Setting of thresholds - • • • Resetting of alarms • • • • Adjustment functions Diagnostics Protection function alarms • Device alarms • Protection unit tripping details • Events log • Protection unit tripping log • Transmission of alarms via SMS optional Transmission of alarms via e-mail optional Maintenance Number of operations • Number of trips • Wear of contacts • Other data Status of circuit-breaker Circuit-breaker position Local/remote mode • 4) • • 1) Ekip Control Panel is available in two versions that can manage a maximum of 10 or 30 circuit-breakers. The number of circuit-breakers may vary depending on their type. For details, ask ABB SACE 2) Circuit-breakers equipped with actuation module, electric accessories, opening and closing releases and spring charging motor 3) Two client web accesses included in the licence 4) Circuit-breakers equipped with auxiliary contacts to indicate position ABB Catalogue | 1SDC200023D0201 | 4/7 Emax2_cap04.indd 7 12/04/2013 13:58:17 Communication devices and systems Supervision of the electrical installation The integration of low voltage devices in communication networks is required in particular for: automated industrial processes, industrial and petrochemical sites, modern data centres and intelligent electricity networks, better known as smart grids. Ekip Com Modules Thanks to the wide range of communication protocols supported, SACE Emax 2 circuit-breakers equipped with Ekip Touch electronic trip units can be integrated into communication networks without the need for external interface devices. The distinctive characteristics of the SACE Emax 2 circuit-breakers offering for industrial communication are: - Wide range of protocols supported; the Ekip Com communication modules enable integration with the most common communication protocols based on RS485 serial lines and the most modern communication systems based on EtherNet infrastructures, which guarantee an exchange of data in the order of 100 Mbit/s. - Installation times reduced to a minimum due to the plug & play technology of the communication modules, which are connected directly to the circuit-breaker terminal box without having to remove the electronic trip unit. - Repetition of communication for greater reliability of the system; the circuit-breaker can be equipped with two communication modules at the same time, allowing the information on two buses to be exchanged simultaneously. - Ready to smart grid; the Ekip Com 61850 module is the solution for integrating SACE Emax 2 circuit-breakers into the automated systems of electrical substations based on the IEC 61850 standard without the need for complex external devices. - Complete supervision of Modbus RTU or Modbus TCP/IP networks via the software for PC Ekip View. 1SDC200494F001 4 4/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 8 12/04/2013 13:58:18 Supervision of switchgear compartment Electronic trip unit Ekip Touch Ekip Touch + Ekip measuring module Ekip Hi Touch Solution Ekip Touch trip units + Ekip com modules Ekip G Touch Ekip Hi-G Touch Protocols supported: Modbus RTU Ekip com Modbus Profibus-DP Ekip com Profibus DeviceNet Ekip com DeviceNet Modbus TCP/IP Ekip com Modbus TCP Profinet Ekip com Profinet EtherNet IP Ekip com EtherNet IEC61850 Ekip com IEC61850 4 Control functions Circuit-breakers opening and closing 1) • • • Measurement functions Currents • • • Voltages - • • Powers - • • Energies - • • Harmonics - - • Network analyzer - - • Data logger • • • Setting of thresholds • • • Resetting of alarms • • • Adjustment functions Diagnostic Protection function alarms • Device alarms • Protection unit tripping details • Events log • Protection unit tripping log • Maintenance Number of operations • Number of trips • Wear of contacts • Other data • Status of circuit-breaker Circuit-breaker position Local/remote mode 2) • • 1) Circuit-breakers equipped with Ekip Com Actuator module, electrical accessories, opening and closing releases and spring charging motor 2) Circuit-breakers equipped with auxiliary contacts to indicate position ABB Catalogue | 1SDC200023D0201 | 4/9 Emax2_cap04.indd 9 12/04/2013 13:58:18 Communication devices and systems Supervision and control software ABB SACE offers software applications that allow the potential of the Ekip electronic trip units to be utilized in the best possible way in terms of the management of power, acquisition and analysis of the electrical values, and testing of the protection, maintenance and diagnostic functions. Overview of the software An overview of the software available and their main characteristics are given below: 4 Software Functions Distinctive characteristics Ekip Connect - commissioning of circuit-breakers - analysis of faults - testing of communication bus - simple and intuitive use - integrated with DOC electrical design software - useable via EtherNet - automatic updating from Internet - off-line mode - multi-media (smart phone, tablet or PC) Ekip View - supervision and control of communication networks - analysis of electrical value trends - condition monitoring - engineering free - analysis of past trends - customizable reports - access via Internet to the installation - possibility of integrating third party devices Ekip T&P interface - testing of protection functions - ordinary maintenance of trip units - test signals can be pre-set or configured as desired - advanced graphical interface - generation of test reports 1SDC200495F001 Ekip Connect Ekip Connect enables data to be exchanged with one or more protection trip units, which: - Assists commissioning of the system; all system parameters and the protection thresholds can be set rapidly in the Ekip trip units thanks to the easy and intuitive navigation pages of the software. - Permits rapid access to diagnostics; it is possible to consult and download the records of events, alarms and the tripping of the trip units, thereby facilitating the identification and understanding of the anomalies. 4/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 10 12/04/2013 13:58:18 - Enables testing of the communication network; Ekip Connect performs an automatic scan of the Modbus RS-485 or Modbus TCP network and determines whether the circuit-breakers have been correctly connected and, when necessary, signals incorrect configurations of the communication parameters (addresses, baud rate, parity). The distinctive characteristics of the software are: - Integration with DOC electrical design software; the adjustments and settings calculated by the DOC software can be downloaded directly into the protection trip units, thereby reducing commissioning times and the probability of errors. - Ease of connection: the Ekip trip units equipped with Modbus TCP Ekip com modules can be controlled directly by the EtherNet network. - Multi-media; Ekip Connect is designed to operate on a PC or on the more modern tablet PCs and smart phones. - Automatic updating from the Internet site; if connected to an Internet site, the software is able to constantly control the availability of any updates. 4 The software is available free of charge on the ABB website www.abb.com/lowvoltage. Media Ekip Connect Software Personal PC Smartphone/Tablet iPhone/iPad Operating system Windows XP, Windows 7, Windows Vista Android iOS Method of connection to the trip units Communication network Test connector Wireless communication Wireless communication Wireless communication SACE Emax 2 trip units Ekip com Modbus RS485 or TCP Ekip T&P Ekip Bluetooth Ekip Bluetooth Ekip Bluetooth SACE Tmax XT trip units Ekip com Ekip T&P Ekip Bluetooth - - SACE Emax,T7,X1,T8 trip units PR120/D-M, PR330/D-M Ekip T&P or BT030 BT030 - - SACE Tmax T trip units PR222DS/PD, Ekip T&P or BT030 PR223DS; PR223/EF BT030 - - Automatic network scan • - - - - Opening and closing of circuit-breakers1) • • • • • Setting of thresholds • • • • • Resetting of alarms • • • • • Reading of electrical measurements • • • • • Displaying of time-current curve • • • • • Reading of past records • • • • • DataLogger download • • • - - Generating of Reports • • • • • Automatic updating from Internet • • • • • Integration with DOC • • • • • Enabling of Ekip T&P Interface • • • • • Use via EtherNet •2) - - - - Functions of reading and control Other functions 1) Circuit-breakers equipped with auxiliary contacts to indicate position 2) only in the presence of Modbus TCP Ekip Com modules ABB Catalogue | 1SDC200023D0201 | 4/11 Emax2_cap04.indd 11 12/04/2013 13:58:18 Communication devices and systems Supervision and control software Ekip View Ekip View is the software for supervising devices connected to a communication network that uses the Modbus RTU or Modbus TCP protocol. 4 It - is the ideal tool for all applications that require: remote control of the system, monitoring of power consumption, fault detection of the system, allocation of energy consumption to the different processes and departments, preventative planning of maintenance. 1SDC200496F001 The main characteristics of Ekip View are: - Engineering free and ready to use software which guides the user in the recognition and configuration of the protection units without the need for any supervision system engineering activities. - Dynamic mimic panel; after automatic scanning of the network, for each of the devices found, Ekip View proposes a dynamic symbol that summarizes the most important information (status, electrical measurements, alarms). The extensive library of electrical symbols enables the entire electrical system to be depicted in detail. - Analysis of trends; the instantaneous and past trends of currents, powers and power factors are represented graphically and can be exported into Microsoft Excel for detailed analysis. - Reports; advanced reports can be created regarding system and communication network diagnostics. Using the Alarm Dispatcher option, the user can receive the most important indications via SMS or e-mail. - Access via web to the installation, thanks to the Web Server function of Ekip View. 4/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 12 12/04/2013 13:58:18 Ekip View Software Communication characteristics Protocol Supported Modbus RTU Modbus TCP Physical layer RS 485 EtherNet Maximum data exchange rate 19200 bps 100 Mbps Operating system Windows XP, Windows 7, Windows Vista Devices supported SACE Emax 2 trip units Ekip com Modbus RS485 Ekip com Modbus TCP SACE Emax,T7,X1,T8 trip units PR120/D-M, PR330/D-M - SACE Tmax T trip units PR222DS/PD, PR223DS - SACE Tmax XT trip units Ekip com - Third party devices optional Licences available 4 1) - up to 30 2) controllable devices - up to 60 2) controllable devices - unlimited number 3) controllable devices Supervision and control functions Opening and Closing of circuit-breakers 4) • Electrical value trends • Log of electrical value trends • Dynamic installation mimic panel • Automatic scanning • Centralized synchronizing of time • 5) Web server function • Redundancy optional OPC server-client optional Measurement functions 6) Currents • Voltages • Powers • Energies • Harmonics • Network analyzer • Data logger • Adjustment functions Setting of thresholds • Resetting of alarms • Diagnostics Protection function alarms • Device alarms • Communication system alarms • Protection unit tripping details • Events log • Protection unit tripping log • Generation of Reports • Transmission of alarms via SMS optional Transmission of alarms via e-mail optional Maintenance Number of operations • Number of trips • Wear of contacts • Other data Status of circuit-breaker Circuit-breaker position local/remote mode • 7) • • 1) Contact ABB SACE to integrate other devices in the Ekip View software 2) can be increased 3) within the physical limit of the protocol used 4) circuit-breakers equipped with Ekip com Actuator module and electrical accessories 5) two client web accesses included in the licence, optional up to 5 accesses 6) according to the values supported by the trip units 7) circuit-breakers equipped with auxiliary contacts for position indication ABB Catalogue | 1SDC200023D0201 | 4/13 Emax2_cap04.indd 13 12/04/2013 13:58:18 Communication devices and systems Supervision and control software Ekip T&P Interface The Ekip T&P Interface software, used together with the Ekip T&P device, enables the electronic protection trip units to be tested for correct operation during the stages of commissioning and system maintenance. Thanks to advanced graphical interfaces, the user can simply select the test to perform: from simple current and voltage signals to more complex wave forms with the presence of harmonic distortion. 1SDC200497F001 4 4/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap04.indd 14 12/04/2013 13:58:19 The software creates and stores all reports, keeping a record of the tests carried out and essential information such as the operator name, date, serial number of the circuit-breaker, type of test and the result. 1SDC200498F001 4 ABB Catalogue | 1SDC200023D0201 | 4/15 Emax2_cap04.indd 15 12/04/2013 13:58:19 Emax2_cap04.indd 16 12/04/2013 13:58:19 Accessories Functional areas 5/2 Standard supply 5/4 Accessories for circuit-breakers 5/6 Signalling 5/7 Control 5/10 Safety 5/15 Protection devices 5/16 Connections 5/18 Interlocks and switching devices 5/20 Accessories for Ekip trip units 5/23 Power supply 5/25 Connectivity 5/25 Signalling 5/27 Measurements and protection 5/28 Displaying and supervision 5/32 Testing and programming 5/33 Spare parts 5/34 5 ABB Catalogue | 1SDC200023D0201 | 5/1 Emax2_cap05.indd 1 15/04/2013 16:51:41 Accessories Functional areas The new SACE Emax 2 circuit-breakers have been designed to optimize the installation and commissioning of accessories. The front of the circuit-breaker features two functional areas, which are protected by separate covers: - Accessories area for the installation of accessories inside the circuit-breaker and Ekip trip unit. The areas dedicated to accessories can be accessed by removing the flange and the accessories covers. On removal, the operating mechanism area remains segregated and protected, providing safety for operators. - Safety area, which delimits the housing of the stored energy operating mechanism of the circuit-breaker. To carry out maintenance on the operating mechanism, the covers of the accessories and safety area must be removed. 5 2 1 1SDC200499F001 1 5/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 2 15/04/2013 16:51:42 As a result of distinct functional areas that determine the operating spaces, the accessorizing logic of the circuit-breakers has been considerably simplified. The auxiliary connection terminal box also features two areas: - Terminals area for housing and inserting the terminals for wiring the auxiliary connections. The terminals can be wired first and then installed on the circuit-breaker terminal box, thereby facilitating cable connection for the operator. - Cartridge modules area, housing for the Ekip modules. These are installed directly from the upper part of the circuit-breaker or of the fixed part without having to remove the Ekip electronic trip unit, thereby minimizing the time required for introducing and commissioning the accessories. 5 3 4 1SDC200500F001 3 1 2 3 4 accessories area safety area terminals area cartridge modules area ABB Catalogue | 1SDC200023D0201 | 5/3 Emax2_cap05.indd 3 15/04/2013 16:51:42 Accessories Standard supply The fixed versions of SACE Emax 2 automatic circuit-breakers and switch-disconnectors are always supplied as standard with the following accessories: - IP30 protection for switchgear door - lifting plates for E2.2 … E6.2 circuit-breaker - front terminals for E1.2 circuit-breaker - adjustable rear terminals for E2.2 … E6.2 circuit-breaker, mounted in HR – HR configuration - screws for securing in the switchgear 1SDC200501F001 5 In addition, for fixed automatic circuit-breakers only: - four standard open/closed auxiliary contacts - AUX 4Q - four terminals for auxiliary connections - mechanical signalling of the tripping of the protection trip unit - TU Reset - Ekip TT power supply and test unit, when a protection trip unit is present with display - contact signalling tripping of Ekip protection trip unit S51. 5/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 4 15/04/2013 16:51:42 The withdrawable versions of automatic circuit-breakers and switch-disconnectors are always supplied as standard with the following accessories: - closed circuit-breaker racked-out mechanism lock - lifting plates for E2.2 ... E2.6 circuit-breakers - lever for racking in and racking out - anti-insertion lock In addition, for withdrawable automatic circuit-breakers only: - four standard open/closed auxiliary contacts - AUX 4Q - four terminals for auxiliary connections - mechanical signalling of the tripping of the protection trip unit - TU Reset - Ekip TT power supply and test unit, when a protection trip unit is present with display. 5 1SDC200502F001 The fixed parts feature: - IP30 protection for switchgear door - anti-insertion lock - standard shutter lock – SL - screws for securing to the floor - adjustable rear terminals, mounted in HR – HR configuration ABB Catalogue | 1SDC200023D0201 | 5/5 Emax2_cap05.indd 5 15/04/2013 16:51:43 Accessories Accessories for circuit-breakers SACE Emax 2 circuit-breakers offer a wide range of accessories developed to satisfy the application and installation requirements of every customer. Automatic circuit-breaker E1.2 E2.2 - E4.2 - E6.2 Switch-disconnector E1.2 E2.2 - E4.2 - E6.2 Derived versions CS MT MTP E2.2 - E4.2 - E6.2 Signalling Standard open/closed auxiliary contacts - AUX 4Q / Open/closed auxiliary contacts - AUX 6Q - Open/closed auxiliary contacts- AUX 15Q / / - / / / / / / - - - / - - - / - - - Auxiliary position contacts - AUP 5 Ready to close signalling contact - RTC / / - - - TU Reset mechanical signalling of the tripping of protection trip unit - TU Reset / / - - - - - Contact signalling tripping of Ekip protection trip unit - S51 / / - - - - - Contact signalling loaded springs – S33 M/2 (supplied with Motor) / / / / - - - Opening and closing release - YO/YC / / / / - - - Second opening and closing release - YO2/YC2 / / / / - - - Undervoltage release - YU / / / / - - - Electronic time-delay device for undervoltage release - UVD / / / / - - - Motor - M / / / / - - - Remote reset - YR / / - / Control Opening and closing release test unit - YO/YC Test Unit / - - - - / / - - - - - - - - - - / Safety Key lock and padlock in open position - KLC and PLC / / / / Key lock and padlock in racked-in / test / racked-out position - KLP and PLP Shutter lock - SL External shutter lock - SLE - - Lock for racking-out mechanism with circuit-breaker in closed position Lock for racking in / racking out the mobile part when the door is open - DLR - - - - Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP - - - - Lock to prevent door opening when circuit-breaker is in closed position - DLC / / / / - - Anti-insertion lock / / / / - - Mechanical operation counter - MOC / / / / - - Protection devices Protection device for opening and closing pushbuttons - PBC - - IP30 Protection / / / / - - IP54 Protection / / / / - - / / / / / Terminal covers - HTC / LTC / - - - - - - Separators - PB / - - - - - - Orientable rear terminal - HR/VR - - Front terminal - F - - - - - - - - Connections Other configurations / / / / Interlocks and switching devices Mechanical interlock - MI Automatic transfer switches - ATS / / / / / / / / / / / / Standard accessory for fixed circuit-breaker Accessory on request for fixed circuit-breaker Standard accessory for mobile part Accessory on request for mobile part Standard accessory for fixed part Accessory on request for fixed part 5/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 6 15/04/2013 16:51:43 1SDC200503F001 Signalling Open / closed auxiliary contacts - AUX SACE Emax 2 circuit-breakers can be equipped with auxiliary contacts that signal the open or closed status of the circuit-breaker. The first block of four standard contacts is always provided with the automatic circuit-breakers. The switching contacts are available in the following configurations: Open / closed auxiliary contacts (AUX 4Q) E1.2 E2.2 … E6.2 4 auxiliary contacts standard • • digital signals • • mixed • • Open / closed supplementary auxiliary contacts (AUX 6Q) 1SDC200504F001 6 auxiliary contacts standard - • digital signals - • mixed - • 5 Open / closed external supplementary auxiliary contacts (AUX 15Q) 15 auxiliary contacts standard • • digital signals • 19 • Maximum number of open / closed auxiliary contacts that can be installed 25 Standard contact Contact for digital signals Type changeover contacts changeover contacts Minimum load 100mA @ 24V 1mA @ 5V Breaking capacity 1SDC200505F001 DC AC 24V - 0.1A 125V 0.3A @ 0ms - 250V 0.15A @ 0ms - 250V 5A @ cosM 1 - 5A @ cosM 0.7 - 400V 5A @ cosM 0.3 - 3A @ cosM 1 - 2A @ cosM 0.7 - 1A @ cosM 0.3 - Electrical diagram reference: figure 1, 81, 91 AUX 6Q is an alternative to the Ekip Signalling 4K module. AUX 15Q is an alternative to the mechanical interlock (MI) and the DLP and DLC locks. ABB Catalogue | 1SDC200023D0201 | 5/7 Emax2_cap05.indd 7 15/04/2013 16:51:44 1SDC200506F001 Accessories Accessories for circuit-breakers Auxiliary position contacts - AUP When the circuit-breaker is a withdrawable version, the position of the mobile part can be signalled electrically by accessorizing the fixed part with one of the following signalling contact units: Auxiliary position contacts (AUP) E1.2 E2.2 … E6.2 standard • - digital signals • - standard - • digital signals - • standard - • digital signals - • Maximum number of auxiliary position contacts that can be installed 6 10 Standard contact Contact for digital signals Type changeover contacts changeover contacts Minimum load 100mA @ 24V 1mA @ 5V 6 auxiliary contacts 5 auxiliary contacts 5 supplementary auxiliary contacts 1SDC200507F001 5 Breaking capacity DC AC 24V - 0.1A 125V 0.3A @ 0ms - 250V 0.15A @ 0ms - 250V 5A @ cosM 1 - 5A @ cosM 0.7 - 5A @ cosM 0.3 - 3A @ cosM 1 - 2A @ cosM 0.7 - 1A @ cosM 0.3 - 400V 1SDC200508F001 Electrical diagram reference: figure 95, 96, 97 Ready to close signalling contact - RTC The ready to close signalling contact – RTC – indicates that the circuit-breaker is ready to receive the closing command. The circuit-breaker is ready to close in the following conditions: - circuit-breaker open - springs loaded - no opening command or locks on the opening command - circuit-breaker reset following tripping of Ekip protection trip unit. Standard contact Contact for digital signals Type Switching Minimum load 100mA @ 24V 1mA @ 5V 24V - 0.1 250V 0.5A @ 0ms / 0.2A 10ms - 250V 3A @ cosM 0.7 - Breaking capacity DC AC Electrical diagram reference: figure 71 5/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 8 15/04/2013 16:51:45 1SDC200509F001 Mechanical signalling of the tripping of protection trip unit - TU Reset The automatic circuit-breakers are always equipped with a mechanical device that signals the tripping status of the protection trip units. After the Ekip trip unit has tripped due to an electrical fault, the signalling device clearly indicates the tripping status on the front of the circuit-breaker. The circuit-breaker can be reset only after the signalling pushbutton has been restored to its normal operating position. The device conforms to the Ansi 86T standard. Contact signalling tripping of protection trip unit Ekip – S51 The contact signals the opening of the circuit-breaker after the Ekip protection trip unit has tripped. The circuit-breaker can only be closed after the “TU Reset” tripped trip unit mechanical signalling pushbutton has been restored to its normal operating position. The switching contact, which is always supplied with the standard version of the automatic circuit-breakers, is also available on request in a version for digital signals (for electrical characteristics, please refer to the RTC contact). It can also be associated to an optional accessory for resetting by remote control - YR. For electromechanical characteristics, please refer to the RTC contact. 5 Electrical diagram reference: figure 11 Contact signalling loaded springs – S33 M/2 This contact is always supplied with a geared motor; it remotely signals the spring status of the circuit-breaker operating mechanism. It is available in both standard version and version for digital signals. Standard contact Contact for digital signals Type changeover contacts changeover contacts Minimum load 100mA @ 24V 1mA @ 5V - 0.1A 125V 0.3A @ 0ms - 250V 0.15A @ 0ms - 250V 5A @ cosM 1 - 5A @ cosM 0.7 - 5A @ cosM 0.3 - 3A @ cosM 1 - 2A @ cosM 0.7 - 1A @ cosM 0.3 - Breaking capacity DC AC 24V 400V Electrical diagram reference: figure 12 ABB Catalogue | 1SDC200023D0201 | 5/9 Emax2_cap05.indd 9 15/04/2013 16:51:45 Accessories Accessories for circuit-breakers 1SDC200510F001 Control Opening and closing release- YO/YC The opening and closing releases enable the circuit-breaker to be controlled remotely. Opening is always possible, while closing is available only when the closing springs of the operating mechanism are loaded and the circuit-breakers is ready to close. The releases operate by means of minimum impulse current duration time of 100 ms. Furthermore, they can operate in permanent service. In this case, if opening command is given by means of the opening release, the circuit-breaker can be closed by de-energizing the opening release and, after a time of at least 30 ms, by controlling the closing. Electrical diagram reference: figure 75, 77 Second opening and closing release - YO2/YC2 For certain installations the redundancy of mechanisms and circuit-breaker operating circuits is often requested. To answer these needs, the SACE Emax 2 circuit-breakers can be equipped with double opening release and double closing release. The technical characteristics of the second opening release remain the same as those of the first opening and closing release. A double opening release can be used for E2.2, E4.2 and E6.2 circuit-breakers; an undervoltage release cannot be used in this case. 5 Electrical diagram reference: figure 72, 79 General characteristics Power supply (Un) AC DC 24V • • 30V • • 48V • • 60V • • 110V…120V • • 220V…240V • • 240V…250V • • 380V…400V • - 415V…440V • - 480V…500V • - Operating limits (IEC60947-2 standards) YO/YO2: 70%...110% Un YC/YC2: 85%...110% Un Inrush power (Ps) 300VA 300W Continuous power (Pc) 3.5VA 3.5W Opening time (YO/YO2) E1.2 20 ms E2.2 … E6.2 35 ms Closing time (YC/YC2) E1.2 50 ms E2.2 … E6.2 50 ms 5/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 10 15/04/2013 16:51:46 Opening and closing release test unit - YO/YC Test Unit The opening and closing releases test unit helps ensure that the various version of releases are running smoothly, to guarantee a high level of reliability in controlling circuit-breaker opening. The test unit ensures the continuity of the opening and closing releases with a rated operating voltage between 24V and 250V (AC and DC), as well as verifies the functions of the opening and closing coil electronic circuit. Continuity is checked cyclically with an interval of 20s between tests. The unit has optic signals via LEDs on the front, which provide the following information: POWER ON: power supply present TESTING: testing in progress TEST FAILED: signal following a failed test or lack of auziliary power supply ALARM: signal given following three failed tests. Two relays with one change-over area also available on board the unit, to allow remote signalling of the following events: Failure of a test - resetting takes place automatically when the alarm stops Failure of three tests - resetting occurs only by pressing the manual RESET on the unit. 5 Charachteristics of device Auxiliary power supply 24V...250V AC/DC Specification of the signalling relays Maximum interruped current 6A Maximum interrupted voltage 250V AC ABB Catalogue | 1SDC200023D0201 | 5/11 Emax2_cap05.indd 11 15/04/2013 16:51:46 Accessories Accessories for circuit-breakers 1SDC200510F001 Undervoltage release – YU The undervoltage release opens the circuit-breaker when there is a significant voltage drop or power failure. It can be used for safe remote tripping, for locking on closing or to control the voltage in the primary and secondary circuits. The power supply for the release is therefore obtained on the supply side of the circuit-breaker or from an independent source. Circuit-breaker closing is permitted only when the release is powered. General characteristics Power supply (Un) 5 AC DC 24V • • 30V • • 48V • • 60V • • 110V…120V • • 220V…240V • • 240V…250V • - 380V…400V • - 415V…440V • - 480V…500V • - Operating limits (IEC60947-2 standards) 70%...110% Un Inrush power (Ps) 300VA 300W Continuous power (Pc) 3.5VA 3.5W Opening time (YU) E1.2 30 ms E2.2 … E6.2 50 ms Electrical diagram reference: figure 73 5/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 12 15/04/2013 16:51:46 Time-delay device for undervoltage release (UVD) The undervoltage release can be combined with an electronic time-delay device for installation outside the circuit-breaker, allowing delayed trip unit tripping with adjustable preset times. Use of the delayed undervoltage trip unit is recommended to prevent tripping when the power supply network for the trip unit is subject to brief voltage drops or power supply failures. Circuit-breaker closing is inhibited when it is not powered. The time-delay device must be used with an undervoltage release with the same voltage. General characteristics Power supply (UVD) AC DC 24-30V - • 48V • • 60V • • 110-127V • • 220-250V • • Adjustable opening time (YU + D): 5 0.5-1-1.5-2-3 s Resetting remotely- YR The reset coil YR permits remote resetting of the circuit-breaker after a release has tripped due to an overcurrent condition. It is available, for all automatic circuit-breakers, with different voltage supply: General characteristics 1SDC200512F001 1SDC200511F001 Power supply (Un) AC DC 24V • • 110V • • 250V • • Operating limits 90%...110% Un Electrical diagram reference: figure 12 and 13 ABB Catalogue | 1SDC200023D0201 | 5/13 Emax2_cap05.indd 13 15/04/2013 16:51:47 Accessories Accessories for circuit-breakers 1SDC200513F001 Motor – M The motor automatically loads the closing springs of the circuit-breaker. The device, which can be installed from the front, automatically reloads the springs of the operating device when they are unloaded and power is present. In the event no power is present, the springs can be manually loaded by a dedicated lever on the operating device. The motor is always supplied with limit switch contact S33 M/2 which signals the status of the springs. General characteristics Power supply (Un) 1SDC200514F001 5 AC DC 24V-30V • • 48V-60V • • 100V…130V • • 220V…250V • • 380V…400V • - 440V…480V (E2.2 ... E6.2) • - Operating limits (IEC60947-2 standards) 85%...110% Un Inrush power (Ps) 300VA 500W Continuous power (Pc) 100VA 100W Loading time E1.2 8 sec E2.2 … E6.2 7 sec Electrical diagram reference: figure 12 and 13 5/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 14 15/04/2013 16:51:47 1SDC200515F001 Safety 1SDC200521F001 1SDC200520F001 1SDC200519F001 1SDC200518F001 1SDC200517F001 1SDC200516F001 Key lock in open position - KLC Thanks to these safety devices, the SACE Emax 2 circuit-breaker can be locked in the open position. The lock can also be used during maintenance activities when the shield of the accessories area is removed. The device is available with lock with different keys – KLC-D (for only one circuit-breaker) or with the same keys – KLC-S (for several circuit-breakers). In this latter case, four different key numbers are available. SACE Emax 2 also allows additional key locks to be installed. With the KLC-A type, the following key locks can be used: – Ronis – Profalux – Kirk – Castell In this case, the key locks must be supplied by the customer. 5 Padlocks - PLC These padlocks allow the circuit-breaker to be kept open by acting directly on the mechanical operating device opening pushbutton. Three different padlock versions are available: – Locking device with plastic structure for up to a maximum of three padlocks of 4 mm – Locking device with metal structure for up to a maximum of two padlocks of 8 mm – Locking device with metal structure for one padlock of 7 mm or for padlock holders The padlocks are always supplied by the customer. Key lock in racked-in / test / racked-out position - KLP This device enables the mobile part to be locked in one of the three positions: racked-in, test and racked-out. This device can be supplied with locks with different keys – KLP-D or with the same keys – KLP-S. Each circuit-breaker can be equipped with a maximum of two key locks. Locking in the racked-in, test and racked-out positions can be achieved by using other key locks – KLP-A. This device is made for Ronis, Profalux, Kirk and Castell keys, which are to be provided by the customer. With the exception of the Castell version, every circuit-breaker can accept up to two key locks. Padlock in racked-in / test / racked-out position - PLP This device can hold up to three padlocks of 8 mm diameter. The structure housing the padlocks can also be used with KLP keylocks. Furthermore, it enables the lock of the moving part in the racked-out position only by means of the additional key lock in racked-out position. Shutter lock – SL When the mobile part is in the test position, the shutters of the fixed part close, maintaining the insulation distance and physically segregating the live parts of the fixed part and the rear section of the mobile part. Furthermore, using two dedicated mechanisms, the upper and lower shutters can be locked independently of one another. This is always supplied with the fixed part of the SACE Emax 2 circuit-breakers and locks the shutters, using a maximum of three padlocks of 4 mm, 6 mm or 8 mm. ABB Catalogue | 1SDC200023D0201 | 5/15 Emax2_cap05.indd 15 15/04/2013 16:51:50 Accessories Accessories for circuit-breakers Protection devices 1SDC200522F001 External shutter lock - SLE This accessory is optional and, using padlocks of 4 mm, 6 mm or 8 mm, allows the shutters to be locked directly from the outside of the fixed part, avoiding the need to work inside. For both lock versions, the padlocks are supplied by the customer. Lock for racking-out mechanism with circuit-breaker in closed position All SACE Emax 2 withdrawable circuit-breakers are always supplied with a lock that prevents the mobile part from being racked in and racked out when the circuit-breaker is in the closed position. To rack in the mobile part, the circuit-breaker must be in the open position. 5 1SDC200523F001 Lock for racking in / racking out the mobile part when the door is open - DLR This accessory, which is mounted on the fixed part, prevents the mobile part from being racked in or out when the switchgear door is open. Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP This safety device prevents the switchgear door from being opened when the mobile part of the withdrawable version of the circuit-breaker is in the racked-in or test position. The circuit-breaker can be racked in when the door is open, which is then closed. This accessory can be installed on both the right-hand or left-hand side of the fixed part. It is available for circuit-breakers E2.2, E4.2 and E6.2. It is an alternative to the mechanical interlock. Lock to prevent door opening when circuit-breaker is in closed position - DLC This prevents the compartment door from being opened when the circuit-breaker is in the closed position (and with the circuit-breaker racked in for withdrawable circuit-breakers). It also locks circuit-breaker closed when the compartment door is open. 1SDC200524F001 Anti-insertion lock The withdrawable circuit-breakers are equipped with special locks that allow the mobile part to be inserted only into the corresponding fixed part. Mechanical operation counter - MOC The number of mechanical operations is often one of the elements that determines the frequency of ordinary maintenance operations on circuit-breakers. With this mechanical operation counter, which is always visible on the front of the circuit-breaker, the user knows how many mechanical operations the device has performed. 5/16 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 16 15/04/2013 16:51:51 1SDC200525F001 1SDC200526F001 Protection device for opening and closing pushbuttons - PBC This accessory is applied to the safety cover of the circuit-breaker and is available in two versions: – Pushbutton protection device, which prevents operations on both opening and closing pushbuttons unless the special key is used. – Padlockable pushbutton protection device, which inhibits one or both of the circuit-breaker switching pushbuttons. - PBC is not compatible with PLC padlocks. 5 1SDC200528F001 1SDC200527F001 IP30 Protection Always supplied with the circuit-breaker, the cover frame is applied to the door of the switchgear to achieve IP30 degree of protection on the front part of the circuit-breaker. 1SDC200531F001 1SDC200530F001 1SDC200529F001 IP54 Protection This transparent cover completely protects the front of the circuit-breaker, enabling IP54 degree of protection to be achieved. This accessory is provided with double key lock (same or different keys). Terminal covers – HTC / LTC These accessories are applied in the terminal area, thereby reducing the risk of direct contact with the live parts of the circuit-breaker. Two versions are available for E1.2: HTC high terminal covers and LTC low terminal covers. Separators - PB These protection devices increase the insulation distance between adjacent phases. They are available for E1.2. ABB Catalogue | 1SDC200023D0201 | 5/17 Emax2_cap05.indd 17 15/04/2013 16:51:53 Accessories Accessories for circuit-breakers Connections The SACE Emax 2 circuit-breakers offer a wide variety of terminals, thereby always guaranteeing an optimal solution for connection to the power circuit. Solution for fixed circuit-breakers Type Abbreviation E1.2 E2.2 E4.2 E6.2 Single stab design Rear orientable terminal * HR VR Iu = 2000A Iu = 3200A Iu = 5000A Iu = 4000A Iu = 6300A Multiple stab design Iu = 2500A 5 Horizontal rear spread terminal SHR Vertical rear spread terminal SVR Extended front terminal EF Front terminal F Front spread terminal ES Terminal for cable FcCuAl 4x240mm2 FcCuAl Standard configuration Configuration on request (*) The orientable terminals are supplied as standard in the HR – HR configuration. 5/18 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 18 15/04/2013 16:51:54 Solutions for fixed parts, withdrawable circuit-breakers Type Abbreviation E1.2 E2.2 E4.2 E6.2 Single stab design Rear orientable terminal * HR VR Iu = 2000A Iu = 5000A Multiple stab design Iu = 2500A Horizontal rear terminal Iu = 3200A Iu = 4000A Iu = 3200A** Iu = 6300A or X performance SHR 5 Vertical rear spread terminal SVR Front terminal F Extended front terminal EF Front spread terminal ES Terminal for cable FcCuAl 4x240mm2 Fc CuAl Flat terminal FL Standard configuration Configuration on request (*) The orientable terminals are supplied as standard in the HR – HR configuration. (**) Fixed parts with Iu 3200A acesssorized with rear orientable terminals with multiple stabs guarantee higher performances in switchboard installations. ABB Catalogue | 1SDC200023D0201 | 5/19 Emax2_cap05.indd 19 15/04/2013 16:51:56 Accessories Accessories for circuit-breakers Interlocks and switching devices Mechanical interlocks These interlock systems enable various opening and closing configurations to be obtained between two or three circuit-breakers. Four types of interlock configuration are available: Types of interlock Possible application Logic Circuit-breakers Type A Excludes the possibility of having two circuit-breakers in the closed position at the same time. Main line power supply and emergency power supply. G 5 1 Available between circuit-breakers of different sizes and with any fixed / withdrawable version 1 2 O O I O O I 1 2 3 O O O I O O O O I 2 Type B Permits a pair of circuit-breakers to be closed if the third is open. The latter can only be closed when the pair is open. Two power supplies from transformers and one emergency power supply. G 2 1 3 I O I O I O 1 2 3 Available between E2.2, E4.2 and E6.2 circuit-breakers and with any fixed / withdrawable version Type C Permits two out of three circuit-breakers to be closed at the same time. Two half-busbars can be powered by a single transformer (bus-tie closed) or by both at the same time (bus-tie open). 1 2 3 O O O I O O O I O O O I O I I I I O I O I 1 2 3 O O O I O O O I O O O I Available between E2.2, E4.2 and E6.2 circuit-breakers and with any fixed / withdrawable version Type D Permits one out of three interlocked circuit-breakers to be closed. Three power supplies on the same busbar that must not operate in parallel. G 1 2 Available between E2.2, E4.2 and E6.2 circuit-breakers and with any fixed / withdrawable version 3 5/20 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 20 15/04/2013 16:51:57 The mechanical interlocks offer multiple solutions for installation that simplify their integration into the switchgear. The interlocks can be mounted: – vertically VR – horizontally HR – mixed L Different types of interlocks can be supplied according to the maximum distance between two interlocked breakers: Configuration Type A Type B, C, D Horizontal 2750mm 1600mm Vertical Breakers - 1000mm E1.2 • - E2.2 • • E4.2 • • E6.2 • • 5 For B, C and D types, the maximum distance between the two furthest breakers is 3200mm for horizontal configurations and 2000mm for vertical configurations. All cables can be cut to guarantee easy installation in switchboards. Mechanical interlocks are not compatible with AUX 15Q or DLP and DLC locks. Automatic Transfer Switches ATS The ATS (Automatic Transfer Switch) is a network-unit transfer device used in installations where switching from the main power line to an emergency line is required in order to ensure that power is supplied to the loads in the case of power abnormalities from the main line. These devices are able to control the entire transfer procedure automatically, but also offer commands for performing the procedure manually. In the event of anomalies in the main line voltage, the opening of the main line circuit-breaker, the starting of the generator set (if present) and the closing of the emergency line are activated according to the parameters set by the user. In the same way, when the main line returns to normal, the reverse transfer procedure is performed automatically. The new generation of ATSs (ATS021 and ATS022) offers the most advanced and complete solution for ensuring service continuity. The ATS021 and ATS022 devices can be used with all automatic circuit-breakers and switch-disconnectors of the Tmax XT family. The ATS021 and ATS022 devices have been designed to be self-powered. ATS022 is also designed for the connection of an auxiliary supply, which enables the use of further functions. The ATS021 and ATS022 devices carry out control of both power supply lines and analyze: – phase imbalance; – frequency imbalance; – phase loss. In addition to the standard control functions, the ATS022 unit also permits: – the priority line to be selected; – a third circuit-breaker to be controlled; – the device to be integrated into a supervision system with Modbus communication (auxiliary supply needed); – parameters to be read and set, and measurements and alarms to be displayed by means of a graphical display. Typical applications are: supply of UPS (Uninterrupted Power Supply) units, operating rooms and primary hospital services, emergency power for civil buildings, airports, hotels, databases and telecommunication systems and power supply of industrial lines in continuous processes. For correct configuration, each circuit-breaker connected to the ATS021 or ATS022 device must be fitted with the following accessories: – mechanical interlock; – motorized control of opening and closing ; – contact for signalling status (open / closed) and contact for signalling tripping; – contact for signalling circuit-breaker racked in (for withdrawable circuit-breaker). ABB Catalogue | 1SDC200023D0201 | 5/21 Emax2_cap05.indd 21 15/04/2013 16:51:57 1SDC200537F001 1SDC200538F001 Accessories Accessories for circuit-breakers Technical characteristics General ATS021 ATS022 Auxiliary supply voltage Not required Supply voltage, Un Max 480 VAC Not required (24-110V DC is required only for Modbus communication and systems of 16 2/3 Hz) Max 480 VAC Frequency, fn Dimensions 5 H L D 50, 60 Hz 16 2/3, 50, 60, 400 Hz H mm 96 96 L mm 144 144 D mm 170 170 Type of installation Installation on front of switchgear Installation on front of switchgear Installation on DIN rail Installation on DIN rail Operating mode Automatic/Manual Automatic/Manual • • • • Characteristics Monitoring of normal and emergency line Control of circuit-breakers on normal and emergency line Environmental conditions Operating thresholds Tests Standards Setting start-up of generator • • Setting switch-off of generator with settable time delay • • Third circuit-breaker - • Selection priority line - • Modbus Rs485 communication - • Display - • Grado di protezione IP20 IP20 Operating temperature -20 … +60 °C -20 … +60 °C Humidity 5% - 90% without condensation 5% - 90% without condensation Undervoltage -30% … -5% Un -30% … -5% Un Overvoltage +5% …+30% Un +5% …+30% Un Frequency thresholds -10% / +10% fn -10% … +10% fn Test Mode • • Mode Test Gen set • • Electronic devices for use in electrical installations EN-IEC 50178 EN-IEC 50178 Electromagnetic compatibility EN 50081-2 EN 50081-2 EN 50082-2 EN 50082-2 IEC 68-2-1 IEC 68-2-1 IEC 68-2-2 IEC 68-2-2 IEC 68-2-3 IEC 68-2-3 Environmental conditions Electrical diagram reference: figures 100,101 and 102. 5/22 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 22 15/04/2013 16:51:57 Accessories Accessories for Ekip trip units The electronic trip unit accessories enable utilization of all the potential of Ekip protection trip units in terms of signalling, connectivity, protection functions and testing. Electronic trip unit Ekip DIP Ekip Touch Ekip Hi-Touch Ekip G Touch Ekip G Hi-Touch Power supply Ekip Supply Battery for Ekip trip units Connectivity Ekip Com Ekip Com Redundant Ekip Com Actuator Ekip Link 5 Ekip Bluetooth Signalling Ekip Signalling 2K Ekip Signalling 4K (1) Ekip Signalling 10K Ekip Power Controller Measurement and Protection Ekip Measuring Pro Ekip Measuring Ekip AUP Ekip RTC Ekip Synchrocheck Ekip LCD Ekip Fan (1) Rating Plug Homopolar toroid Toroid for differential protection Current sensor for neutral conductor outside the circuit-breaker Displaying and Supervision Ekip Multimeter Ekip Control Panel Testing and Programming Ekip TT Ekip T&P (1) Standard accessory Accessory on request not available for E1.2 ABB Catalogue | 1SDC200023D0201 | 5/23 Emax2_cap05.indd 23 15/04/2013 16:51:57 Accessories Accessories for Ekip trip units All accessories are automatically recognized by the Ekip units without the need for any specific configuration. Based on the installation method and connection of the trip units, the electronic accessories can be divided into: Installation Modules Highlights - The Ekip Supply module enables the trip units to be supplied with several line voltage Terminal box Cartridge modules: Ekip Com Ekip Link Ekip 2K Ekip Supply Ekip Fan Ekip Synchrocheck - If the Ekip Supply module is present, the other cartridge modules can be installed - The Ekip Supply module has a dedicated position in the installation area in the terminal box; the other modules can be installed as desired in the positions available - In addition to the Ekip Supply module, up to 2 modules can be installed on E1.2, and up to 3 on E2.2, E4.2 and E6.2 - Ekip fan module is available for E2.2, E4.2 and E6.2 as an aletnative to Ekip supply module 5 - These are installed in specific housings from the front of the circuit-breaker Accessorizing area Ekip LCD Ekip Com Actuator Ekip RTC Ekip AUP Ekip Measuring Ekip Signalling 4K Rating Plug Battery for Ekip - For all the trip units with a touch screen interface, the LCD interface is available with any adjustment in the protection and measurements functions - Thanks to the optional modules Ekip RTC and Ekip AUP, all the Ekip trip units can acquire and monitor the ready to close state and the racked-in/ test isolated/racked-out position of the circuit-breaker. The module to acquire the open/closed position is supplied as standard for all Ekip trip units. - The Ekip Signalling 4k module increases the remote signalling possibilities for E2.2, E4.2 and E6.2 Ekip trip unit test connector External Ekip T&P Ekip TT Ekip Bluetooth - These are connected to the front test connector of the trip units even with the device in operation Ekip Multimeter Ekip Control Panel Ekip 10K - Ekip Multimeter can supply the trip unit to which it is connected External neutral sensor Homopolar toroid Differential toroid - These are connected to the trip unit by the terminal box of the circuitbreaker - Compatible also with the SACE Tmax XT range - Several Ekip Multimeter units and / or Ekip Signalling 10K can be connected at the same time to the same Ekip trip unitsganciatore Ekip 5/24 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 24 15/04/2013 16:51:57 1SDC200539F001 Power supply Ekip Supply Power Supply module The Ekip Supply module enables all Ekip trip units and modules present on the terminal box to be supplied with several auxiliary power in AC or DC available in the switchgear. The module can be mounted at any time on the circuit-breaker terminal box and permits installation of the cartridge modules; it is an alternative to the Ekip Fan module. Two versions are available according to the primary voltage used: – Ekip Supply 110-240V AC/DC – Ekip Supply 24-48V DC Electrical diagram reference: figures 31, 32 5 1SDC200540F001 Connectivity The Ekip Com modules enable all SACE Emax 2 circuit-breakers to be integrated in an industrial communication network for remote supervision and control of the circuit-breaker. They are suitable for all distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units. Since it is mounted to the terminal box, communication can be maintained with withdrawable circuit-breakers, even while in the racked-out position. Several Ekip Com modules can be installed at the same time, thereby enabling connection to communication systems that use different protocols. The Ekip Com modules are supplied complete with auxiliary position contacts Ekip AUP and ready to close circuit-breaker contacts Ekip RTC. The Ekip Com and Profibus module are equipped with a dip switch that allows the introduction of a 120: resistor to terminate a Modbus RTU network. For industrial applications where superior reliability of the communication network is required, the Ekip Com R communication modules, installed together with the corresponding Ekip Com modules, guarantee redundant connection to the network. The Ekip Com modules enable Ekip trip units to be connected to networks that use the following protocols: Protocol Ekip Com Module Modbus RTU Ekip Com Modbus RS-485 Ekip Com Redundant Module Ekip Com R Modbus RS-485 Modbus TCP Ekip Com Modbus TCP Ekip com R Modbus TCP Profibus-DP Ekip Com Profibus Ekip Com R Profibus Profinet Ekip Com Profinet Ekip Com R Profinet EtherNet / IP Ekip Com EtherNet / IP Ekip Com R EtherNet / IP DeviceNet Ekip Com DeviceNet Ekip Com R DeviceNet IEC61850 Ekip com IEC61850 Electrical diagram reference: figures from 51 to 57. Redundant version from 61 to 66. ABB Catalogue | 1SDC200023D0201 | 5/25 Emax2_cap05.indd 25 15/04/2013 16:51:58 Accessories Accessories for Ekip trip units 1SDC200541F001 Ekip Link Module The Ekip Link module enables the SACE Emax 2 circuit-breaker to be connected to ABB communication system for locally supervising switchgear by means of the Ekip Control Panel and to act as Power Controller. It is suitable for all Ekip trip units and can be fitted at any time to the circuit-breaker terminal box, even when Ekip Com communication modules are present. In this way, it is possible to have both local supervision of the control panel by means of the Ekip Control Panel and supervision of the system by means of the Ekip Com modules connected to the communication network. The Ekip Link modules are supplied complete with auxiliary position contacts Ekip AUP and ready to close circuit-breaker contacts Ekip RTC. Electrical diagram reference: figure 58 Ekip Com Actuator module The Ekip Com Actuator module enables the SACE Emax 2 circuit-breakers to be opened and closed remotely. The Ekip com Actuator is optional and can be ordered for all Ekip trip units equipped with Ekip Com or Ekip Link modules; it is installed on the front of the circuit-breaker in the right-hand accessories area. 1SDC200542F001 5 Electrical diagram reference: figure 76, 78 1SDC200543F001 Ekip Bluetooth wireless communication unit Ekip Bluetooth permits remote connection with the trip unit by portable PC, tablet or smart phone on which Ekip Connect software has been installed. The device is connected to the front test connector found on all Ekip trip units in SACE Emax 2 and SACE Tmax XT circuitbreakers and supplies power by means of a rechargeable Li-ion battery. 5/26 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 26 15/04/2013 16:51:59 Signalling 1SDC200544F001 Ekip 2K Signalling modules The Ekip 2K Signalling modules supply two input and two output contacts for control and remote signalling of alarms and circuit-breaker trips. They can be programmed from the trip unit’s display. Furthermore, by means of the Ekip Connect software, combinations of events can be freely configured. They are suitable for all distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units. Three different Ekip 2K Signalling modules are available: Ekip 2K-1, Ekip 2K-2, Ekip 2K-3. In this way, a maximum of three modules for E2.2, E4.2, E6.2, and two for E1.2 can be installed at the same time. Electrical diagram reference: figures 41, 42, 43 1SDC200545F001 Ekip 4K signalling module The Ekip 4K Signalling module, available for E2.2 – E4.2 – E6.2, supplies four input contacts and four output contacts for control and remote signalling. It can be programmed from the trip unit’s display. Furthermore, by means of the Ekip Connect software, combinations of events can be freely configured. It is installed in the housing provided in the front left of distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units, without having to remove the trip unit itself. 5 1SDC200546F001 Electrical diagram reference: figure 2 Ekip 10K signalling unit Ekip 10K Signalling is a signalling unit on a DIN rail for SACE Emax 2 automatic circuitbreakers. The unit provides ten contacts for electrical signalling of timing and tripping of protection devices. If connected via the Ekip Connect software, the contacts can be freely configured in association with any event and alarm or combination of both. Several Ekip 10K Signalling (max 4) can be installed at the same time on the same Ekip trip unit. The Ekip 10K Signalling module can be powered both in direct current and in the alternating current and can be connected to Ekip Touch and Hi-Touch trip units via internal bus or Ekip Link modules. Electrical diagram reference: figure 103 ABB Catalogue | 1SDC200023D0201 | 5/27 Emax2_cap05.indd 27 15/04/2013 16:52:00 Accessories Accessories for Ekip trip units Characteristics of output contacts Number of contacts Type Monostable Maximum switching power (resistive load) 1250VA Maximum switching voltage 150V DC / 250V AC Maximum switching current 30V DC 2A 50V DC 0.8A 150V DC 0.2A 250V AC 4A Contact/coil insulation Ekip 2K Ekip 4K 2 output +2 input 4 output +4 input Ekip 10K 10 output + 11 input 2000 Vrms (1min @50Hz) Ekip 10K signalling unit power supply 1SDC200547F001 5 Auxiliary supply 24-48V DC, 110-240V AC/DC Voltage range 21.5-53V DC, 105-265V AC/DC Rated power 8W Signalling contacts for Ekip trip units Ekip trip units can acquire the status of circuit-breaker ready to close (RTC) and the racked-in, test, or racked-out position though the optional signalling contacts Ekip RTC and Ekip AUP. These contacts, housed in the accessories area of the circuit-breakers, are available with Ekip Dip, Ekip Touch and Ekip Hi-Touch. Ekip COM communication modules and Ekip Link modules are always supplied with Ekip AUP and Ekip RTC contacts. 1SDC200548F001 Measurement and protection Ekip Measuring module The Ekip Measuring module enables the trip unit to measure the phase and neutral voltages, powers and energy. The Ekip Measuring module is installed on the front, right housing of the distribution protection versions of the Ekip Touch trip units, without having to remove the trip unit itself. The voltage connections are installed by default on the lower terminals. The measuring module requires no external connection since it is connected internally to the lower or upper terminals of Emax 2. If necessary, the voltage outlet connection can be moved outside the circuit-breaker by using voltmetric transformers and the alternative connection positioned in the terminal box. The use of external connections is obligatory for rated voltages that are higher than 690V. The module must be disconnected for dielectric strength tests on the main busbars. Electrical diagram reference: figures 20, 21, 22, 23 5/28 | 1SDC200023D0201 | ABB Catalogue 1SDC200549F001 Ekip Measuring Pro module The module has the same connection and installation characteristics as the Ekip Measuring module. In addition, the Ekip Measuring Pro version has: – Protection devices based on the voltage and power values – Ekip trip unit power supply from busbar voltage (for line voltages greater than 85V) – LED signalling voltage on main busbars. The Ekip Hi-Touch, Ekip G Touch and Ekip G-Hi Touch trip units are provided as standard with the Ekip Measuring Pro module. 1SDC200550F001 Electrical diagram reference: figures 20, 21, 22, 23 Ekip Synchrocheck This module enables the control of the synchronism condition for placing two lines in parallel. The module can be used with distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units equipped with the Ekip Measuring Pro module. Ekip Synchrochek acquires the voltages of two phases of one line through an external transformer and, through the Ekip Measuring Pro module, the voltages of another line. An output contact is available, which is activated upon reaching synchronism, and enables the circuit-breaker to be closed by means of wiring with the closing release. Characteristics of output contacts 5 Number of contacts Type Monostable Maximum switching power (resistive load) 120W /1250VA Ekip Synchrocheck Maximum switching voltage 150V DC / 250V AC Maximum switching current 30V DC 3A 50V DC 1A 150V DC 0.3A 250V DC Contact/coil insulation 1 output 4A 2000 Vrms (1min @50Hz) (Phase) 220Vac Ekip Measuring YC External operating mechanism (synchronizing unit or manual operating mechanism) 1SDC200551ENF001 Ekip G Touch (Neutral) Supply SYNCRO Vbar1 Vbar2 Electrical diagram reference: figure 48 ABB Catalogue | 1SDC200023D0201 | 5/29 Emax2_cap05.indd 29 15/04/2013 16:52:01 1SDC200552F001 Accessories Accessories for Ekip trip units 1SDC200553F001 5 Ekip LCD display interface For installations in particularly aggressive environments, as low temperatures, high humidity or presence of dust or chemical agents, the Ekip protection trip units can be requested with an LCD black and white display interface with pushbuttons for navigation. This version guarantees excellent immunity by integrating all functions, with regard to protection devices, measuring devices and the possibility of introducing accessories, available on the colour touch screen. Ekip Fan cooling module The Ekip Fan cooling module continuously monitors the temperature inside the fixed parts of E2.2, E4.2 and E6.2 that are equipped with cooling fans and activates them in the event of overheating. It is an alternative to the Ekip Supply module and enables the protection trip unit to be supplied with DC auxiliary power available in the switchgear. Ekip Fan can be used with Ekip Touch and Ekip Hi-Touch trip units. The Ekip Fan 24V DC is available. If an Ekip Fan 24V DC module is installed, another two cartridge modules can also be installed. 1SDC200554F001 Electrical diagram reference: figure 33 Rating Plug The rating plugs are field interchangeable from the front on all trip units and enable the protection thresholds to be adjusted according to the actual rated current of the system. This function is particularly advantageous in installations that may require future expansion or in cases in which the power supplied needs to be limited temporarily (e.g. mobile Gen Set). The Overload (L) protection function can be disabled at any time by using an L OFF version of the rating plug. There is a matching L OFF version for each standard version of rating plug. Circuit-breaker Rating plugs available (both in standard and L OFF versions) E1.2 400-630-800-1000-1250-1600 E1.2 250 100-200-250 E2.2 400-630-800-1000-1250-1600-2000-2500 E2.2 250 100-200-250 E4.2 400-630-800-1000-1250-1600-2000-2500-3200-4000 E6.2 400-630-800-1000-1250-1600-2000-2500-3200-4000-5000-6300 Special rating plugs are also available for differential protection against earthing faults in combination with a suitable toroid to be installed externally. Circuit-breaker Rating plug available for Rc protection E1.2 400-630-800-1000-1250-1600 E1.2 250 100-200-250 E2.2 400-630-800-1000-1250-1600-2000-2500 E2.2 250 100-200-250 E4.2 400-630-800-1000-1250-1600-2000-2500-3200-4000 5/30 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 30 15/04/2013 16:52:03 1SDC200555F001 1SDC200556F001 Current sensor for neutral conductor outside the circuit-breaker This is only for three-pole circuit-breakers; it enables protection of the neutral conductor to be achieved through connection to the Ekip trip unit. It is supplied on request. Electrical diagram reference: figure 27 Homopolar toroid for the earthing conductor of main power supply The distribution and generator protection versions of the Ekip Touch and Hi-Touch trip units can be used with an external toroid positioned, for example, on the conductor that connects the star centre of the MV/LV transformer to earth (homopolar transformer): in this case, the earth protection is called Source Ground Return. Through two different combinations of connections of its terminals, the In of the toroid can be set at 100 A, 250 A, 400 A, 800 A. 5 1SDC200557F001 Electrical diagram reference: figure 25 Toroid for differential protection Connected to the Ekip Touch and Hi-Touch trip units equipped with a rating plug for differential protection, this toroid enables earth fault currents of 3…30A to be monitored. To be installed on the busbar system, it is an alternative to the homopolar toroid. Electrical diagram reference: figure 24 ABB Catalogue | 1SDC200023D0201 | 5/31 Emax2_cap05.indd 31 15/04/2013 16:52:03 Accessories Accessories for Ekip trip units Displaying and supervision 1SDC200558F001 Ekip Multimeter Display on front of switchgear Ekip Multimeter is a display unit to be installed on the front of the switchgear for SACE Emax 2 circuit-breakers equipped with Ekip electronic trip units. The device, 96mmx96mm sized, is equipped with a large touch screen display and enables measurements to be displayed with the same levels of precision. If connected to trip units with a display, Ekip Multimeter enables the adjustment of parameters and protection thresholds. Several Ekip Multimeter devices can be connected at the same time to the same Ekip protection trip unit to display currents, voltage, powers and energy. Ekip Multimeter can be powered either in direct current (24-48V DC or 110-240V DC) or in alternating current (110-240V AC). It is equipped with a 24V DC output that supplies the trip unit to which it is connected. 1SDC200559F001 5 Power supply 24-48V DC, 110-240V AC/DC Tolerance 19.2-60V DC, 105-265V AC/DC Rated Power 8W Ekip Control Panel on front of switchgear The Ekip Control Panel enables the SACE Emax 2 circuit-breakers connected to the Ekip Link system to be controlled and monitored. The panel is supplied already equipped with supervision software and requires no programming. Ekip Control Panel requires a 24V DC power supply and is equipped with: – 2 RJ45 EtherNet ports for connection to the Ekip Link system and to the local network for remote control via web server option – 1 RS485 serial port for integration of the Modbus network if it is to be used with circuitbreakers of the Tmax series – 4 USB ports for downloading data. 5/32 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 32 15/04/2013 16:52:04 1SDC200561F001 1SDC200560F001 Testing and programming Ekip TT testing and power supply unit Ekip TT is a device that allows you to verify that the circuit-breaker trip mechanism is functioning correctly (trip test). It also allows a trip unit not provided with auxiliary power supply to be supplied with power so that the last protection device tripped can be displayed directly on the screen or by the lighting up of corresponding LEDs. The device can be connected to the front test connector of any Ekip trip unit of SACE Emax 2; it is supplied as standard with the versions for distribution and generator protection of the Ekip Touch, Hi-Touch trip units to set protection functions setting. Ekip T&P testing kit Ekip T&P is a kit that includes different components for programming and testing the electronic protection trip units. The kit includes: – Ekip T&P unit; – Ekip TT unit; – adaptors for Emax and Tmax trip units; – USB cable to connect the T&P unit to the Ekip trip units; – installation CD for Ekip Connect and Ekip T&P interface software. The Ekip T&P unit is connected on one side to the USB port of a PC and on the other, by means of the cable provided, to a protection trip unit of the SACE Emax 2 series. The Ekip T&P unit performs the automatic testing, manual testing and trip testing of the device to which it is connected and generates reports. These functions are managed via the Ekip T&P Interface, which is activated directly by Ekip Connect only in the presence of the Ekip T&P connected to a PC. 5 ABB Catalogue | 1SDC200023D0201 | 5/33 Emax2_cap05.indd 33 15/04/2013 16:52:04 Accessories Spare parts Spare parts The following original and guaranteed spare parts are available: – Front shield and lateral covers – Opening solenoid for Ekip protection trip unit – Arc chamber – Complete pole – Operating mechanism and closing springs – Loading lever for closing springs – Racking-out lever – Racking-out handle and plates – Jaw isolating contact for fixed part of withdrawable circuit-breaker – Shutters for fixed part – Trip units - current transformers wires – Transparent protection for trip unit – Mainboard for protection trip units – Terminal box and e sliding contacts – Grease and oil. 5 For further details, please refer to ABB SACE Spare Parts Catalogue. 5/34 | 1SDC200023D0201 | ABB Catalogue Emax2_cap05.indd 34 15/04/2013 16:52:04 Installation Circuit-breaker 6/2 Sizes 6/3 Versions 6/4 Poles 6/5 Terminals 6/6 Degree of protection 6/7 Power losses 6/7 Temperature derating 6/8 Current-limiting curves 6/9 Installation environment Temperature 6/10 Environmental conditions 6/10 Vibration 6/10 Electromagnetic compatibility 6/10 Installation in switchgear 6/11 Position 6/12 Power supply 6/12 Insulation distances and connection 6/12 Busbar types 6/14 Accessories 6/14 Performance in switchgear 6/15 6 ABB Catalogue | 1SDC200023D0201 | 6/1 Emax2_cap06.indd 1 15/04/2013 09:53:47 Installation Circuit-breaker The new SACE Emax 2 family maintains the characteristics of strength and reliability that have always distinguished the tradition of ABB SACE air circuit-breakers. The new SACE Emax 2 circuit-breakers, available in four sizes, are extremely compact due to their new dimensions: with reduced depths and heights, combined with rationalized widths, they provide the answer to the most stringent installation requirements. Safety is guaranteed thanks to the double insulation of the live parts and total segregation of the phases. Furthermore, the new functional design of the SACE Emax2 circuit-breakers has been developed with the purpose of improving installation operations and use of the devices and accessories; making them simple, intuitive and safe. Distinctive characteristics - Ekip protection trip units are interchangeable from front of circuit-breaker - Rapid configuration of the Ekip trip units 6 - Electronic modules can be installed on terminal box without removing the electronic trip units and protection shield Benefits Reduced times during the stages of: - installation - wiring - configuration - commissioning - maintenance - Electrical plug-in accessories can be installed from the front of circuit-breaker - New push-in terminal box allows rapid auxiliary connections Simplicity of use and safety - Horizontal or vertical rear connections can be modified on-site by turning 90° Increased level of safety - Accessorizing logic common to the entire family of circuit-breakers - Accessory cabinet and terminal box are stamped with accessory codes for easy identification - Accessories area is separated functionally from the safety area - Mechanical safety locks in open position are active when the shield is removed - Guided racking in and out of the mobile part 6/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 2 15/04/2013 09:53:47 Sizes The SACE Emax2 circuit-breakers, available in 4 sizes up to 6300A, provide: - Versatility, where installation space is a critical and influential factor, such as naval applications, wind turbine towers or switchgear - Opportunities, optimization of the dimensions of the electrical switchgear results in a potential reduction in the consumption of the materials used. 6300A 6 4000A 1SDC200562F001 2500A 1600A Emax E1.2 Emax E2.2 Emax E4.2 Emax E6.2 ABB Catalogue | 1SDC200023D0201 | 6/3 Emax2_cap06.indd 3 15/04/2013 09:53:47 Installation Circuit-breaker Versions The SACE Emax2 circuit-breakers are available in both fixed and withdrawable versions. The withdrawable version is recommended in applications in which service continuity is a fundamental requirement: replacement of the moving part with a new device does not require any intervention on power connections or on auxiliary connections, thus permitting reset in the shortest time possible. The fixed version, which is connected directly to power system through the circuit-breaker terminals, is recommended in applications in which the need for space means that compact products are required without compromising the performance and possibility of fitting accessories. 6 Fixed Withdrawable 2 4 4 1 3 7 7 6 5 1. 2. 3. 4. 5. 6. 7. 8. 1SDC200564F001 8 1SDC200563F001 8 Moving part Sliding contacts Fixed part Terminal box Racking-out mechanism Racking-out guide rails Pushbuttons Data label and accessories 6/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 4 15/04/2013 09:53:49 Poles SACE Emax 2 circuit-breakers are available in three-pole and four-pole versions and can be used in all types of distribution systems. Furthermore, thanks to the possibility of connecting the external current sensor, three-pole circuit-breakers can be used efficiently even in systems in which the neutral conductor cannot be isolated. The four-pole circuit-breakers E1.2, E2.2 and E4.2 are always provided with full-size neutral pole with rated uninterrupted current-carrying capacity identical to the phase poles. The E6.2 circuit-breakers, thanks to their construction modularity, are available with neutral set at 50% - normal supply – and with full-size neutral, so that the customer does not need to oversize the neutral unless strictly necessary. The apparatus supplied as standard are suitable for connection of phases in the sequence L1, L2, L3 for three-pole circuitbreakers, or N, L1, L2 and L3 for four-pole circuit-breakers with neutral on the left; a special optional kit enables the position of the circuit-breaker neutral to be changed to the right, making the sequence L1,L2,L3,N available. 6 Circuit-breaker Standard version Three-pole Emax E1.2 L1 L2 Optional version with neutral on the right Four-pole L3 N L1 Four-pole L2 L3 L1 L2 L3 N Emax E2.2 Emax E4.2 Emax E6.2 ABB Catalogue | 1SDC200023D0201 | 6/5 Emax2_cap06.indd 5 15/04/2013 09:53:49 Installation Circuit-breaker Terminals The integration of the circuit-breaker in the electrical system is simplified thanks to the connection terminals of the circuitbreakers. The silver-plated copper terminals are designed to assist installation of connecting bars according to the change in the rated capacity of the circuit-breaker. Each terminal has been created to the standard width of busbar for that amperage and is equipped with one, two or three terminal stabs for easy connection to multiple bus runs that may be required for the application.For particular installation requirements, the circuit-breakers can be equipped with different combinations of terminals for the upper and lower part. 6 Type Abbreviation E1.2 E2.2 E4.2 E6.2 Rear orientated terminal (1) HR VR F, W F, W F, W F, W Horizontal rear spread terminal SHR W F, W Vertical rear spread terminal SVR Front terminal F F F, W F, W F, W Extended front terminal EF F, W Front spread terminal ES F, W Terminal for cable FcCuAl 4x240mm2 Fc CuAl F, W Flat terminal FL W W W F, W (1) The reare orientated terminals are supplied as sandard in the HR-HR configuration. 6/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 6 15/04/2013 09:53:50 Degree of protection The SACE Emax2 circuit-breakers guarantee the following degrees of protection: - IP20 for circuit-breakers in fixed or withdrawable versions, excluding the terminals. - IP30 for the front parts of the circuit-breaker when installed in switchgear with IP30 flange mounted on the door. - IP54 for circuit-breakers equipped with optional IP54 transparent flange fixed on the door in front of the switchgear. Power losses To guarantee the performance of the electrical switchgear in terms of rated uninterrupted current-carrying capacity, the design of the electrical switchgear must take into consideration the power losses by the apparatus and by live parts installed. These power losses are measured according to IEC 60947 product standard, the values given in the table refer to total power for three and four pole circuit-breakers with balanced loads with a current flow equal to rated uninterrupted current "Iu" at 50/60Hz. Circuit-breaker type Iu 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A [W] 31 50 78 122 201 - - - - - - E2.2 B/N/S/H [W] - 34 53 83 136 212 267 - - - - E4.2 N/S/H/V [W] - - - - - - - 425 465 - - E6.2 H/V/X [W] - - - - - - - - 309 483 767 E1.2 B/C/N [W] 62 100 156 244 400 - - - - - - E2.2 B/N/S/H [W] - 72 113 176 288 450 550 - - - - E4.2 N/S/H/V [W] - - - - - - - 743 900 - - E6.2 H/V/X [W] - - - - - - - - 544 850 1350 E1.2 B/C/N Fixed Withdrawable 6 ABB Catalogue | 1SDC200023D0201 | 6/7 Emax2_cap06.indd 7 15/04/2013 09:53:50 Installation Circuit-breaker Temperature derating Under certain installation conditions, the circuit-breakers can operate at higher temperatures than the reference temperature of 40°C. In this case the current-carrying capacity of the circuit-breaker may be lower than the rated current-carrying capacity at the reference temperature: therefore the derating coefficients shown in the table must be applied. Percentage values refer to withdrawable circuit breakers. Emax 2 E1.2 6 Temperature [°C] <40 45 50 55 60 65 70 E1.2 250 100% 100% 100% 100% 100% 100% 100% E1.2 630 100% 100% 100% 100% 100% 100% 100% E1.2 800 100% 100% 100% 100% 100% 100% 100% E1.2 1000 100% 100% 100% 100% 100% 100% 100% E1.2 1250 100% 100% 100% 100% 100% 100% 100% E1.2 1600 100% 100% 100% 98% 95% 93% 90% Emax 2 E2.2 Temperature [°C] <40 45 50 55 60 65 70 E2.2 250 100% 100% 100% 100% 100% 100% 100% E2.2 800 100% 100% 100% 100% 100% 100% 100% E2.2 1000 100% 100% 100% 100% 100% 100% 100% E2.2 1250 100% 100% 100% 100% 100% 100% 100% E2.2 1600 100% 100% 100% 100% 100% 100% 98% E2.2 2000 100% 100% 100% 100% 95% 91% 87% E2.2 2500 100% 100% 100% 100% 98% 94% 90% Emax 2 E4.2 Temperature [°C] <40 45 50 55 60 65 70 E4.2 2000 100% 100% 100% 100% 100% 100% 100% E4.2 2500 100% 100% 100% 100% 100% 100% 100% E4.2 3200 100% 100% 97% 93% 89% 86% 82% E4.2 4000 100% 100% 94% 90% 86% 83% 80% Emax 2 E6.2 Temperature [°C] <40 45 50 55 60 65 70 E6.2 4000 100% 100% 100% 100% 100% 100% 100% E6.2 5000 100% 100% 100% 100% 100% 98% 95% E6.2 6300 100% 100% 95% 91% 87% 84% 81% 6/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 8 15/04/2013 09:53:50 Current-limiting curves The SACE Emax2 series features a series of current-limiting circuit-breakers in sizes E1.2 up to 1600A. These circuit-breakers are distinguished constructively by: – Dedicated stored energy operating mechanism, which reduces opening times. – Specific main contacts which, utilizing the electrodynamic forces generated by the short-circuit current, accelerate opening of the main contacts. These features ensure rapid interruption which consequently reduces electromechanical and thermal stress on the system during a short-circuit. The current-limiting circuit-breakers are distinguished by short-time withstand currents Icw that are not particularly high and therefore not indicated for applications in which chronoamperometric selectivity is required with several downstream devices or in which devices are present with high inrush current in the start-up stage. Current-limiting curves Current-limiting curves of specific let-through energy E1.2 L E1.2 L 6 690V 380/415V 690V 1SDC200567F001 1SDC200566F001 380/415V ABB Catalogue | 1SDC200023D0201 | 6/9 Emax2_cap06.indd 9 15/04/2013 09:53:51 Installation Installation environment SACE Emax 2 circuit-breakers have been designed and tested in accordance with major international Standards to manage with maximum reliability the electrical plant. The installation requirements prescribed by the international Standards are listed below. In addition, ABB provides instructions for the use of circuit-breakers in nonstandard environments, as for example personalized maintenance program or installation solutions aimed at increasing performances and extending the lifecycle of the circuit-breaker. Temperature SACE Emax2 circuit-breakers can operate in the following environmental conditions: Temperature (°C) Operating Active Display Storage Emax 2 with Ekip DIP -25°C … +70°C - -40°C … +70°C Emax 2 with Ekip Touch -25°C … +70°C -20°C … +70°C -30°C … +70°C Emax 2 with LCD -25°C … +70°C -25°C … +70°C -40°C … +70°C Emax 2 swith-disconnectors -25°C … +70°C - -40°C … +70°C Environmental conditions 6 The devices can be installed in industrial environments with pollution level 3, IEC 60947. SACE Emax 2 circuit-breakers also comply with: – IEC60721-3-6 class 6C3 – IEC60721-3-2 class 3C2 Altitude SACE Emax2 air circuit-breakers do not undergo changes in rated performance up to 2000 metres. Beyond this altitude, the properties of the atmosphere in terms of composition, dielectric capacitance, cooling power and pressure vary and, therefore, the performance of the circuit-breakers is subject to derating, which can be measured by means of the variation in maximum rated service voltage and rated uninterrupted current. Altitude Rated service voltage - Ue [m] 2000 3000 4000 5000 Versions 690V [V] 690 607 538 470 Versions 1150V [V] 1150 1012 897 782 [% In] 100 98 93 90 Rated current An installation at 3000 m of a 690 V AC rated service voltage can be an explicative example. The altitude, as shown in the table, may cause a derating which precludes the use of a standard automatic circuit-breaker. To grant the use of a circuit-breaker at 690 V AC rated service voltage is therefore required a 1150V AC version that – despite the derating – fulfill the necessary rated service voltage. In addition, the selection of the circuit-breakers has to be based on the short -circuit performance required by the application. Vibration The circuit-breakers have been tested according to: – IEC60068-2-6 - From 1 to 13 Hz with amplitude 1mm - From 13 to 100 Hz with constant acceleration 0.7g – IEC60721-3-1 - Storage: 1M3 – IEC60721-3-2 - Transport: 2M2 – IEC60721-3-3 - Operational conditions: 3M2 – Shipping registers or certifications Electromagnetic compatibility The use of specific devices in industrial installations may cause electromagnetic interference in the electrical system. SACE Emax2 circuit-breakers have been developed and tested for electromagnetic compatibility in accordance with IEC 60947-2, Appendices J and F. 6/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 10 15/04/2013 09:53:51 Installation Installation in switchgear Thanks to the four construction sizes and the reduced insulation distances required, SACE Emax2 circuit-breakers enable the installation spaces of the compartments of electrical switchgear to be optimized, thereby providing a rational solution to the customers’ application needs. Emax E1.2 Emax E2.2 Emax E4.2 Emax E6.2 1600 A 2500 A 4000 A 6300A 1SDC200568F001 6 400...600 300...400 600...800 1000...1200 SACE Emax2 circuit-breakers enable the design of electrical switchgear to be improved, allowing it to be optimized not just in terms of performance, but also in the use of the main materials: – Copper: thanks to the possibility of developing compact units, the length of the distribution system / busbar can be minimized. – Metal frame and structure: reduced volumes also mean less surface space is used for panels and internal structures. – Space: the optimization of the individual units benefits the entire switchgear, which is more compact and can therefore be installed taking up less surface space. Traditional circuit-breaker 3p Iu 2500A Emax E2.2 3p Iu 2500A Efficiencies with Emax 2: Possibility of saving in copper Possibility of saving in metal frame, segregation and plates 1SDC200569F001 Possibility of saving in the installation surface 600 400 200 ABB Catalogue | 1SDC200023D0201 | 6/11 Emax2_cap06.indd 11 15/04/2013 09:53:51 Installation Installation in switchgear Position All SACE Emax2 circuit-breakers can be floor mounted in a vertical position inside the switchgear compartment. The E1.2 circuit-breaker can also be installed in a horizontal position and wall mounted. Power supply The Emax2 circuit-breakers can be supplied, indifferently, from either upper or lower terminals. In the event a measurement module is present, in order to make use of all information when the circuit-breaker is in the open position, the voltage sockets must be installed on the power supply side. Insulation distances and connection The circuit-breakers can be connected to the main power system using the most common configurations and dimensions of copper bars. Installation of live parts must ensure: D 6 C B A 1SDC200570F001 – Minimum insulation distances between the phases Rated insulation voltage Ui Minimum distance [mm] 1000V 14mm according to IEC 61439; ABB suggests 25mm – Insulation distance of installation cubicle Fixed circuit-breakers D C Withdrawable circuit-breakers A B C [mm] 3p 4P E1.2 250 322 382.5* E2.2 400 490 500 E4.2 500 600 500 E6.2 900 1000 E6.2/f - 1200 A B [mm] 3p 4P 130 E1.2 280 221 E2.2 400 221 E4.2 500 500 221 E6.2 900 1000 500 355 500 221 E6.2/f - 1200 500 355 C D 350 440* 252 490 500 355 600 500 355 * 390mm for voltage less d440V AC 1SDC200571F001 * 332.5mm for voltage less d440V AC D B A 6/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 12 15/04/2013 09:53:51 L [mm]: Max distance of the first anchorage plate from the circuit breaker terminals – Anchorage plates The electrodynamic force released during a short-circuit can cause high levels of mechanical stress to the devices and structures of the switchgear. To minimize this, fastening plates must be positioned near the circuit-breaker terminals. E1.2 E2.2 E4.2 E6.2 6 Ipk [kA]: Peak current 1SDC200572ENF001 – Tightening torques The following table indicates the values required for connecting the circuit-breaker terminal and the connecting bars. Terminals E1.2 E2.2 / E4.2 / E6.2 Modifiable HR/VR rear 40 Nm 70 Nm Spread rear 40 Nm 70 Nm Front 40 Nm 70 Nm Extended front 40 Nm 70 Nm Spread front 70 Nm 70 Nm Front for cables 43 Nm 70 Nm – Segregation plates and separator plates The rear part of the circuit-breaker has been designed with specific slots in which insulating walls can be housed to facilitate segregation of live parts. In addition, phase separators are available as an optional accessory for E1.2. Earthing connection To achieve continuity and equipotentiality of earthing between the Emax 2 circuitbreaker and the protection citcuit of the switchboard, customers can do either of the options below: – Connect the Emax 2 fixed circuit-breaker or the fixed part of the withdrawable circuit-breaker to the protective circuit by means of a cable with suitable crosssectional area to fulfil the requirements of clause 10.5.2 fo the Standard IEC 61439-1. – If the continuity of the circuit-breaker frame with the switchboard earthing is guaranteed by the metal contact (support) between the circuit-breaker and the metal structure of the switchboard (which is a part of the protective circuit) no connection is necessary (provided that no panels of insulating material are interposed between the circuit-breaker and the metal frame of the switchboard). Emax E1.2, fixed version, does not require any earthing connection. ABB Catalogue | 1SDC200023D0201 | 6/13 Emax2_cap06.indd 13 15/04/2013 09:53:51 Installation Installation in switchgear Busbar types The circuit-breakers, via the terminals, can be connected to the main distribution system by busbars of different types: copper, silver-plated copper and tinned aluminium when the main distribution system is made of aluminium. The circuit-breakers can be connected directly with copper or aluminium cables in the case of E1.2 circuit-breakers, or indirectly by cable-carrying bars in the case of E2.2, E4.2 e E6.2. Accessories 6 The SACE Emax 2 circuit-breakers offer a wide range of accessories that improve safety levels for technicians working on the switchgear and circuit-breakers. Furthermore, thanks to the different types of mechanical interlock available, pre-determined coordination strategies can be achieved between the circuit-breakers. In detail: – Horizontal and vertical interlocks between circuit-breakers – Door lock with circuit-breaker in closed position – Switchgear door lock in racked-in/out position – Lock of racked-out mechanism with door open – External lock of shutters – Flange for switchgear door IP30 and IP54 1SDC200573F001 For further information of the operation of accessories, see chapter 5. 6/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 14 15/04/2013 09:53:52 Installation Performance in switchgear The many types of switchgear that can be created and the installation and environmental conditions can considerably influence the performance of the circuit-breaker. In this regard, SACE Emax 2 circuit-breakers offer the best solution for improving the capacity in switchgear. The following application situations have been assessed by taking into consideration the main factors that can influence the performance of the circuit-breaker in switchgear: – Type of switchgear – Switchgear degree of protection – Segregation form 3 – Size of circuit-breaker – Number of devices connected at the same time in the unit – Type of terminal and connection – Ambient temperature Ta (IEC61439-1 ) – Withdrawable circuit-breakers – Maximum withstand temperature for the terminal 120° C 6 ABB Catalogue | 1SDC200023D0201 | 6/15 Emax2_cap06.indd 15 15/04/2013 09:53:52 Installation Performance in switchgear The following tables provide an indication of the performance of the apparatus inside the switchgear. The data shown are a summary of software model simulations and real tests. HR Terminal One circuit-breaker in the column SACE Emax 2 E1.2 B C N Circuit-breaker Switchgear dimensions 2200x400x600 (HxLxD) Environment temperature IP Iu IP31 630 800 Connection [mm] 2x40x5 2x50x5 2x50x10 1000 6 2x50x8 Compartment 2 Compartment 1 1SDC200574F001 2x50x10 1250 2x50x8 3x50x8 1600 2x50x10 Compartment 35 °C 45 °C 55 °C 630 630 630 800 800 800 1000 1000 1000 1250 1250 1200 1440 1360 1290 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 Performances with EF, SHR and F terminals can be compared, with the same connection sections, to the performances of circuit-breaker with HR terminal. Performances with ES terminals can be compared to the VR terminals. Performances with FC CuAl terminals, with cables in the prescribed sections, can be compared to HR performances. 6/16 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 16 15/04/2013 09:53:53 HR Terminal Two circuit-breakers in the column Environment temperature VR Terminal One circuit-breaker in the column Environment temperature 35 °C 45 °C 55 °C 630 630 630 630 630 630 800 800 800 800 800 800 970 930 900 1000 960 920 1200 1150 1100 1250 1200 1140 1330 1260 1220 1370 1315 1262 35 °C 630 45 °C 630 VR Terminal Two circuit-breakers in the column Environment temperature 55 °C 630 800 800 800 1000 1000 1000 1250 1250 1250 1520 1440 1330 35 °C 45 °C 55 °C 630 630 630 630 630 630 800 800 800 800 800 800 1000 1000 950 1000 1000 970 1250 1250 1150 1250 1250 1200 1430 1355 1265 1475 1415 1310 6 ABB Catalogue | 1SDC200023D0201 | 6/17 Emax2_cap06.indd 17 15/04/2013 09:53:53 Installation Performance in switchgear The following tables provide an indication of the performance of the apparatus inside the switchgear. The data shown are a summary of software model simulations and real tests. HR Terminal One circuit-breaker in the column SACE Emax 2 E2.2 B N S H Circuit-breaker Switchgear dimensions 2200x600xx900 (HxLxD) Environment temperature IP Iu Connection [mm] IP31 Compartment 35 °C 45 °C 55 °C 800 800 800 1000 1000 1000 1250 1250 1250 1600 1540 1480 2000 1940 1850 2000 2000 1940 2500 2350 2200 2500 2460 2320 2 800 1x50x10 1 2 1000 2x50x5 1 2 1250 2x50x10 1 2 6 2x60x10 1600 Compartment 2 1 2 1x100x10 1 1SDC200574F001 2 Compartment 1 3x60x10 1 2 2x80x10 2000 1 2 3x60x10 * 1 2 2x80x10 * 1 2 3x60x10 1 2 4x100x5 2500 1 2 3x60x10 * 1 2 4x100x5 * 1 * Performances refer to SHR and SVR terminals. Performances with F and FL terminals can be compared to the performance of circuit-breakers with HR terminals. 6/18 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 18 15/04/2013 09:53:54 HR Terminal Two circuit-breakers in the column Environment temperature VR Terminal One circuit-breaker in the column Environment temperature 35 °C 45 °C 55 °C 800 800 800 800 800 800 1000 1000 1000 1000 1000 1000 1250 1250 1250 1250 1250 1250 1470 1410 1360 1550 1490 1430 1920 1810 1720 1950 1850 1760 2000 1900 1810 2000 1945 1850 2280 2200 2100 2400 2310 2170 2394 2310 2205 2500 2430 2280 35 °C 800 1000 1250 45 °C 800 1000 1250 VR Terminal Two circuit-breakers in the column Environment temperature 55 °C 800 1000 1250 35 °C 45 °C 55 °C 800 800 800 800 800 800 1000 1000 1000 1000 1000 1000 1250 1250 1250 1250 1250 1250 6 1600 1600 1520 2000 2000 1920 2000 2000 2000 2500 2450 2350 2500 2500 2460 1500 1470 1400 1580 1550 1475 1950 1860 1760 2000 1920 1810 2000 1950 1850 2000 2000 1900 2400 2270 2160 2500 2380 2270 2500 2390 2270 2500 2500 2380 ABB Catalogue | 1SDC200023D0201 | 6/19 Emax2_cap06.indd 19 15/04/2013 09:53:54 Installation Performance in switchgear The following tables provide an indication of the performance of the apparatus inside the switchgear. The data shown are a summary of software model simulations and real tests. HR Terminal VR Terminal One circuit-breaker in the column One circuit-breaker in the column SACE Emax 2 E4.2 N S H V Circuit-breaker Switchgear dimensions 2200x800xx900 (HxLxD) Environment temperature IP Environment temperature Iu Connection Compartment 35 °C [mm] 45 °C 55 °C 35 °C 45 °C 55 °C 2000 2x80x10 1 2000 2000 2000 2000 2000 2000 2500 2x100x10 1 2500 2450 2400 2500 2500 2500 3200 3x100x10 1 3050 2900 2755 3200 3080 2920 3200 3x100x10* 1 3200 3050 2850 3200 3200 3020 4000 4x100x10 1 3450 3200 2970 3650 3400 3200 IP31 6 Compartment 1 1SDC200574F001 Compartment 2 * Performances refer to withdrawable circuit-breakers with a fixed part accessorized with three stab rear terminals for 4000A (Example: 1SDA074021R1 - KIT VR 4000A) Performances with F and FL terminals can be compared to the performances of circuit-breaker with HR terminal. 6/20 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 20 15/04/2013 09:53:55 The following tables provide an indication of the performance of the apparatus inside the switchgear. The data shown are a summary of software model simulations and real tests. HR Terminal VR Terminal One circuit-breaker in the column One circuit-breaker in the column SACE Emax 2 E6.2 H V X Circuit-breaker Switchgear dimensions 2200x1200xx900 (HxLxD) Environment temperature IP Environment temperature Iu Connection Compartment 35 °C [mm] 45 °C 55 °C 35 °C 45 °C 55 °C 4000 4x100x10 4000 4000 4000 4000 4000 IP31 1 4000 6 Compartment 1 5000 5x100x10 1 5000 5000 4900 5000 5000 5000 6300 7x100x10 1 5650 5350 4850 6000 5700 5250 1SDC200574F001 Compartment 2 Performances with F and FL terminals can be compared to the performances of circuit-breaker with HR terminal. ABB Catalogue | 1SDC200023D0201 | 6/21 Emax2_cap06.indd 21 15/04/2013 09:53:56 Installation Performance in switchgear The following tables provide an indication of the performance of the apparatus inside the switchgear. The data shown are a summary of software model simulations and real tests. HR Terminal VR Terminal One circuit-breaker in the column One circuit-breaker in the column SACE Emax 2 E1.2 L Circuit-breaker Switchgear dimensions 2200x400x600 (HxLxD) Environment temperature IP Environment temperature Iu Connection Compartment 35 °C [mm] 45 °C 55 °C 35 °C 45 °C 55 °C 630 2x40x5 1 630 630 630 630 630 630 800 2x50x5 1 800 800 800 800 800 800 2x50x10 1 1000 1000 950 1000 1000 1000 1250 1205 1050 IP31 6 Compartment 2 1000 1SDC200574F001 2x50x8 Compartment 1 2x50x10 1 2x50x8 1 1250 1125 955 1250 Performances with EF, SHR and F terminals can be compared, with the same connection sections, to the performances of circuit-breaker with HR terminal. Performances with ES terminals can be compared to the VR terminals. Performances with FC CuAl terminals, with cables in the prescribed sections, can be compared to HR performances 6/22 | 1SDC200023D0201 | ABB Catalogue Emax2_cap06.indd 22 15/04/2013 09:53:56 Dimensions Fixed circuit-breaker 7/2 E1.2 7/4 E2.2 7/8 E4.2 7/12 E6.2 7/14 Withdrawable circuit-breaker 7/18 E1.2 7/20 E2.2 7/24 E4.2 7/28 E6.2 7/30 7 ABB Catalogue | 1SDC200023D0201 | 7/1 Emax2_cap07.indd 1 15/04/2013 17:55:42 Dimensions Fixed circuit-breaker E1.2 E2.2 - E4.2 - E6.2 A A B Y B 40 C C Y 136,5 296 X 168.5 Y 6 12 Y 1SDC200581F001 x 1SDC200580F001 x 273 331 X A B [mm] 4p 3p 3p 4p E1.2 280 210 103.6 103.6 E2.2 366 276 138 138 E4.2 510 384 192 192 E6.2 888 762 318 444 - - 444 E6.2/f 1014 C 7 Compartment door drilling E1.2 E2.2 - E4.2 - E6.2 306 244 Y 226 100 X 37 X 100 100 Y Ø4 n°6 holes Y 1SDC200582F001 348 X 100 X 100 112 224 153 179 Y 158 Ø5 n°8 holes E1.2 E2.2 - E4.2 - E6.2 12.5 1SDC200583F001 E1.2 2 3 130 MIN A MIN (48) A MIN 164 MAX A MAX (88) A MAX Standard Ronis/Profalux Kirk Castell A MIN [mm] 49.5 63.5 63.5 83.5 A MAX [mm] 83.5 97.5 97.5 117.5 E2.2-E4.2-E6.2 Standard Ronis/Profalux Kirk Castell A MIN [mm] 31 41.5 45.5 - A MAX [mm] 71 81.5 85.5 - 7/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 2 15/04/2013 17:55:43 Dimensions of the compartment D D A B [mm] 3p 4p E1.2 250 E2.2 400 E4.2 500 E6.2 900 1SDC200584F001 B 1SDC200571F001 C C A B E6.2/f - C D 322 382.5 * 130 490 500 221 600 500 221 1000 500 221 1200 500 221 * 332.5 for voltages d 440V AC A 7 Floor fixing Y A = Ø 10.5 X C X 1SDC200585F001 = Y A (III) A (IV) B 117 187 117 117 80 E2.2 154 244 154 154 150 E4.2 208 334 208 208 150 E6.2 460 460 334 460 150 586 - 460 150 3p 4p Earthing device E2.2 - E4.2 - E6.2 52.5 39.75 Ø 10 MAX X 35 X R10 Y Ø 5.5 - M5 B 17.5 1SDC200586F001 1) [mm] 3p 4p A 192.5 262.5 B 70 140 1SDC200587F001 8 122.5 E1.2 4p 61.25 Y 245 C 3p E6.2/f - Wall fixing (only for E1.2) A B [mm] M4x8 screws supplied Tightening torque 1.5Nm 1) for fixing with rear terminals ABB Catalogue | 1SDC200023D0201 | 7/3 Emax2_cap07.indd 3 15/04/2013 17:55:43 Dimensions Fixed circuit-breaker - E1.2 Front terminals – F 129 3 280 (IV) 210 (III) 24 10 4 105 10 Y 1 10 1 134 102 X 291 X 268 X 5 Y 25 X 204 MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE 50 178 70 70 184 70 Extended front terminals – EF 129 70 7 29.5 70 70 Y 4 7 ~100 15 1 2 ~100 95 150 150 173 20 X X 134 102 20 291 204 2 X X 268 20 5 Y 6 105 210 (III) 178 280 (IV) 184 25 2 MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE Ø 11 15 14 12.5 25 95 = 44 = 20.5 1 2 3 4 Front terminals for flat connection Extended front terminals To be supplied by the customer Tightening torque 18Nm 5 6 7 Door position - Ref. page 7/2 Obligatory phase separators 100mm Obligatory insulating plate to be supplied by the customer 1SDC200594F001 Key 7/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 4 15/04/2013 17:55:44 Orientable rear terminals - HR/VR 280 (IV) 210 (III) 105 7.5 Y 7.5 23.5 1.5 12.5 138.5 277 x x 295 55 R 5.5 25.5 18 Y 73 = 44 = Terminals HR 184 3 59 7 12.5 129 1 70 70 127.25 102 x 254.5 15 N 4 1 Y R 5.5 x 204 1 70 Y L1 L3 L2 MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE 178 Terminals VR 184 70 59 129 2 70 12.5 3 70 3.75 2 15 2 Y 2 106 x x x 212 204 x x Y MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE 4 178 70 3.75 70 4 70 1 2 3 4 Horizontal orientable terminals HR Vertical orientable terminals VR Tightening torque 20Nm Door position - Ref. page 7/2 1SDC200595F001 Key ABB Catalogue | 1SDC200023D0201 | 7/5 Emax2_cap07.indd 5 15/04/2013 17:55:45 Dimensions Fixed circuit-breaker - E1.2 Splayed extended front terminals - ES 3-pole version 116 116 23 Y ~200 1 230 258.5 55 56 100 X X 5 Y 105 210 7 = 90 = 31.5 45 = 90 = 15 31.5 45 22.5 15 22.5 20 20 171.5 171.5 4-pole version 116 116 129 116 40.5 23 1 Y 15 1 2 ~200 ~200 230 1 2 258.5 56 134 102 100 X 100 X X 204 X 268 3 5 90 4 Y 105 MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE 178 280 = 90 = 22.5 = 90 = 31.5 45 15 31.5 45 31.5 45 22.5 20 = 90 = 15 171.5 31.5 45 15 22.5 20 20 = 90 = 15 22.5 171.5 20 171.5 171.5 1 2 3 Splayed extended front terminals Tightening torque 18Nm Door position - Ref. page 7/2 4 5 Obligatory phase separators 200mm Obligatory insulating plate to be supplied by the customer 1SDC200596F001 Key 7/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 6 15/04/2013 17:55:46 Front terminals for cables – FcCuAl 184 280 (IV) 210 (III) 5 105 129 2 59.25 3 20 Y 1 27.75 9 95 134 268 X 166 147.5 20 20 191.5 1 202 102 291 X 404 204 X 26 X 150 9 95 4 Y 70 70 101 70 MIN. 130 - MAX. 164 WITH FLANGE 170 WITHOUT FLANGE 178 = 58 = 1 7 70 28 38 13 16.75 Ø 21.5 30.4 31 73 31.5 31.6 87 25 1 2 3 Front terminals for cables FC CU AL Tightening torque 43Nm Tightening torque 18Nm 4 5 Door position - Ref. page 7/2 Obligatory insulating plate to be supplied by the customer 1SDC200597F001 Key ABB Catalogue | 1SDC200023D0201 | 7/7 Emax2_cap07.indd 7 15/04/2013 17:55:47 Dimensions Fixed circuit-breaker - E2.2 Orientable rear terminals - HR/VR E2.2 B/N/S/H 2000A E2.2 N/S/H 2500A 366 (IV) 270 276 (III) 9 138 40 35 - 2000A 47 - 2500A 35 9 15 2 4 10 331 325 8 168.5 35 - 2000A 47 - 2500A 47 40 15 2 4 10 124 114 114 93 98 98 33 114 M5 98 24 6 12 7 5 84 48 MIN 88 MAX 5 6 7 1 150 3 6 5 6 23 E2.2 B/N/S/H 2000A 7 1 3 2000A Ø 13 35 90 90 90 10 12 33 N 45 60 90 2 50 L1 L2 90 L3 90 10 N L1 L2 L3 E2.2 N/S/H 2500A 1 3 2500A 3 4 90 90 30 Ø 13 35 90 10 12 N 33 45 60 4 L1 90 L2 90 L3 90 10 60 250 N L1 L2 L3 1 2 3 Horizontal terminals 2000A Vertical terminals 2000A Horizontal terminals 2500A 4 5 6 Vertical terminals 2500A Tightening torque 2000A 8.6Nm Tightening torque 2500A 8.6Nm 7 8 9 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 Insulating wall 1SDC200598F001 Key 7/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 8 15/04/2013 17:55:48 Front terminals – F 366 (IV) 270 22 276 (III) 20 138 4 15 Y 1 1 40 3 451 X X 331 X 325 X 168.5 2 3 5 M5 2 39 6 12 Y 84 15 48 MIN 88 MAX 20 150 23 Lower front terminals – F Upper front terminals – F 7 1 2 230 15 167 Ø 13 15 Ø 13 35 60 35 60 1 2 3 Upper front terminals Lower front terminals Tightening torque 8.6Nm 4 5 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 1SDC200599F001 Key ABB Catalogue | 1SDC200023D0201 | 7/9 Emax2_cap07.indd 9 15/04/2013 17:55:49 Dimensions Fixed circuit-breaker - E2.2 Horizontal spread terminals – SHR E2.2 B/N/S/H 2000A E2.2 N/S/H 2500A 366 (IV) 276 (III) 270 138 57 9 Y 9 3 4 69 1 2 40 10 10 325 X X 331 X X X 124 X 114 8 168.5 M5 93 98 5 6 24 12 Y 6 7 84 48 MIN 88 MAX 150 23 = E2.2 B/N/S/H 2000A 7 1 = 60 = 10 35 15 55 60 100 10 1 3 1 Y L1 L3 L2 130 2 4 2 130 Y III = 45 = 35 130 2 4 67 130 90 Y 1 3 15 55 67 IV = 60 = Y L2 L1 N 2 L3 = 45 = E2.2 N/S/H 2500A 3 = 60 = 30 35 10 15 55 67 130 2 4 130 Y 1 3 60 100 4 = 60 = L1 130 2 4 30 35 3 Y III L3 L2 90 130 Y 10 1 3 4 15 55 67 IV N = 60 = L1 Y L2 L3 = 60 = 1 2 3 Side horizontal splayed terminals 2000A Central horizontal splayed terminals 2000A Side horizontal splayed terminals 2500A 4 5 6 Central horizontal splayed terminals 2500A Tightening torque 2000A 8.6Nm Tightening torque 2500A 8.6Nm 7 8 9 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 Insulating wall 1SDC200600F001 Key 7/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 10 15/04/2013 17:55:50 Vertical spread terminals – SVR 366 (IV) 270 276 (III) 57 69 138 Y 1 40 X X 331 325 X X 6 168.5 X 194 X 194 M5 58 58 24 12 2 Y 6 3 5 48 MIN 88 MAX 4 84 150 23 E2.2 B/N/S/H 2000A 7 = 60 = 1 10 35 90 90 15 1 90 10 Y 55 67 60 N 100 Y L2 L1 1 L3 = 45 = E2.2 N/S/H 2500A 2 30 = 60 = 10 35 90 90 15 55 100 10 67 N 60 L1 2 90 Y Y L2 2 L3 = 60 = 1 2 3 Vertical splayed terminals 2000A Vertical splayed terminals 2500A Tightening torque 2000A 8.6Nm 4 5 6 Tightening torque 2500A 8.6Nm Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 1SDC200601F001 Key ABB Catalogue | 1SDC200023D0201 | 7/11 Emax2_cap07.indd 11 15/04/2013 17:55:51 Dimensions Fixed circuit-breaker - E4.2 Orientable rear terminals - HR/VR E4.2 N/S/H/V 3200A E4.2 N/S/H/V 4000A 510 (IV) 270 276 Y 40 4 35 325 X X X 8 2 4 134 X X X 114 9 2 4 10 X X X 35 - 3200A 47 - 4000A 114 X X 114 98 88 98 98 24 Y 6 0A 0A M5 168.5 12 9 9 20 331 X 47 35 - 3200A 47 - 4000A 9 138 192 7 384 (III) 84 48 MIN 88 MAX 150 23 5 6 7 1 5 1 3 5 6 5 6 E4.2 N/S/H/V 3200A 7 1 3 N L2 L1 126 126 Y L3 126 1 35 20 12 Ø 13 N 33 L2 L1 L3 45 2 1 2 2 Y = 80 = 126 126 Y 126 20 = 70 = Y N L2 L1 L3 Y E4.2 N/S/H/V 4000A 1 3 N L2 L1 126 126 Y L3 126 3 35 50 12 10 Ø 13 33 N L3 Y 4 3 4 L2 L1 45 = 80 = 4 Y 126 126 126 10 10 = 80 = Y 1 3 N L1 L2 L3 1 2 3 Horizontal terminals 3200A Vertical terminals 3200A Horizontal terminals 4000A 4 5 6 Vertical terminals 4000A Tightening torque 3200A 20Nm Tightening torque 4000A 20Nm 7 8 9 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 Insulating wall 1SDC200602F001 Key 7/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 12 15/04/2013 17:55:53 Front terminals – F 510 (IV) 4 276 138 270 22 15 Y 20 1 40 1 3 X 331 445.5 X 325 X X 5 168.5 3 2 3 MØ 5 6 24 33.5 12 Y 2 15 192 48 MIN 88 MAX 384 (III) 84 20 150 23 8 Lower front terminals Upper front terminals 7 1 2 171.5 240 15 15 Ø 13 Ø 13 35 80 35 80 1 2 3 Upper front terminals Lower front terminals Tightening torque 20Nm 4 5 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 1SDC200603F001 Key ABB Catalogue | 1SDC200023D0201 | 7/13 Emax2_cap07.indd 13 15/04/2013 17:55:54 Dimensions Fixed circuit-breaker - E6.2 Horizontal rear terminals – HR E6.2 H/V/X 5000A E6.2 H/V/X 6300A 888 (IV) 762 (III) 270 444 (IV) 40 51 51 7 318 (III) Y 7 20 331 X 325 X X X 6 168.5 Y 6 12 138 X 134 X 114 M5 24 98 88 1 3 5 276 10 84 48 MIN 88 MAX 150 2 4 23 E6.2 H/V/X 5000A 7 252 1 2 1 35 20 12 III 45 189 1 63 L2 252 1 2 = 80 = 252 Y L1 33 13 Y L3 252 Y 63 = 70 = IV Y L1 N L2 L3 E6.2 H/V/X 6300A 252 1 2 2 35 50 12 Y III 10 13 45 189 L2 252 1 2 10 = 80 = 63 2 Y L1 33 252 L3 252 Y 63 = 80 = IV Y N L1 L2 L3 1 2 3 4 Horizontal terminals 5000A Horizontal terminals 6300A Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm 5 6 7 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 Insulating wall 1SDC200604F001 Key 7/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 14 15/04/2013 17:55:55 Vertical rear terminals – VR E6.2 H/V/X 5000...6300A 888 (IV) 762 (III) 444 (IV) 40 51 318 (III) 1 2 Y 325 X X 331 168.5 12 Y 6 X 6 98 5 9 114 M5 24 138 276 X 3 4 84 48 MIN 88 MAX 150 23 E6.2 H/V/X 5000A 7 1 1 35 252 252 3 20 Y 1 63 12 33 III 45 Y L1 1 Ø 13 = 80 = 189 L2 3 = 70 = L3 252 252 63 Y IV Y L1 N L2 L3 E6.2 H/V/X 6300A 2 2 35 252 4 50 Y 63 2 10 12 33 Ø 13 252 III 2 10 = 80 = Y L1 45 189 L2 252 63 Y 4 = 80 = L3 252 IV Y N L1 L2 L3 1 2 3 4 Vertical terminals 5000A Vertical terminals 6300A Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm 5 6 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 1SDC200605F001 Key ABB Catalogue | 1SDC200023D0201 | 7/15 Emax2_cap07.indd 15 15/04/2013 17:55:56 Dimensions Fixed circuit-breaker - E6.2 Orientable rear terminals - HR/VR full size E6.2 H/V/X 5000A E6.2 H/V/X 6300A 1014 444 270 276 40 51 15 51 138 9 Y 20 331 X 325 X X X 8 168.5 X 134 X 114 12 6 1 24 11 7 84 48 MIN 88 MAX 9 10 X X X 114 X 9 2 4 X 114 M5 98 88 Y 51 15 51 9 2 4 5 150 7 98 5 6 8 3 6 98 5 6 23 E6.2 H/V/X 5000A 7 1 2 35 252 1 3 20 252 252 Y 63 12 33 Y 45 N L1 L2 L3 Ø 13 = 80 = = 70 = 252 252 2 252 Y 63 Y N L1 L2 L3 E6.2 H/V/X 6300A 35 252 Y 63 10 Y 33 N L1 L2 L3 45 4 10 = 80 = 252 50 12 Ø 13 252 1 3 3 4 252 252 252 Y 63 = 80 = Y N L1 L2 L3 1 2 3 Horizontal terminals 5000A Vertical terminals 5000A Horizontal terminals 6300A 4 5 6 Vertical terminals 6300A Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm 7 8 9 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 Insulating wall 1SDC200606F001 Key 7/16 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 16 15/04/2013 17:55:57 Front terminals – F 1014 (IV FS) 888 (IV) 444 (IV/IV FS) 318 (III) 15 4 Y 270 26 20 1 1 40 3 445.5 X X 331 325 X X 6 15 33.5 Y 12 M5 2 2 24 138 84 276 48 MIN 88 MAX 762 (III) 8 2 3 5 168.5 20 150 23 Lower front terminal Upper front terminals 7 1 2 240 Ø 13 171.5 15 35 252 80 35 252 189 Y L1 L2 Y 80 252 252 252 63 15 Ø 13 Y L3 N L1 3-pole Y 252 252 63 63 Y L2 4-pole L3 N L1 Y L2 L3 4-pole full size 1 2 3 Upper front terminals Lower front terminals Tightening torque 20Nm 4 5 Door position - Ref. page 7/2 Earthing device - Ref. page 7/3 1SDC200607F001 Key ABB Catalogue | 1SDC200023D0201 | 7/17 Emax2_cap07.indd 17 15/04/2013 17:55:58 Dimensions Withdrawable circuit-breaker E1.2 E2.2 - E4.2 - E6.2 A A B B C C Y x 363.5 159.5 425 X X 1SDC200588F001 x 1SDC200589F001 343 Y 185.5 A B [mm] 4p 3p 3p 4p E1.2 348 278 155.5 155.5 E2.2 407 317 158.5 158.5 E4.2 551 425 212.5 212.5 E6.2 929 803 338.5 464.5 - - 464.5 E6.2/f 1055 C Y Y 7 Compartment door drilling E1.2 E2.2 - E4.2 - E6.2 306 244 Y 226 Y 179 100 X X X 100 1SDC200582F001 37 100 X 348 100 112 224 153 100 Y Ø4 n°6 holes Y 158 Ø5 n°8 holes Distance from connected to isolated position E1.2 E2.2 - E4.2 - E6.2 C 305 12.5 C E1.2 3 40 3 251 275.5 2 B 75 B 1SDC200590F001 47 Standard Ronis/Profalux Kirk Castell B [mm] 44.5 55 55 85 C [mm] 36 46.5 46.5 76.5 E2.2-E4.2-E6.2 Standard Ronis/Profalux Kirk Castell C [mm] 17.5 28 32 - B [mm] 24 34.5 38.5 - B refers to KLC; C refers to KLP 7/18 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 18 15/04/2013 17:55:59 Dimensions of the compartment D D A B [mm] 3p 4p E1.2 280 E2.2 400 E4.2 500 600 500 355 E6.2 900 1000 500 355 1200 500 355 1SDC200570F001 B 1SDC200591F001 C C A B E6.2/f - C D 350 440* 252 490 500 355 * 390 for voltages d 440V AC A 7 Floor fixing A E (III) E (IV) Y A (III) X 50 B (III) 75 F (III) X Ø 10 A (IV) Y B (IV) Earthing device E2.2 - E4.2 - E6.2 = C = 1SDC200592F001 Y D (IV) D (III) 1SDC200593F001 C 3p 4p 3p 4p E1.2 80 150 80 80 E2.2 75 170 75 80 E4.2 100 225 100 E6.2 363 375 237 375 - E6.2/f - D E F 3p 4p 3p 4p 100 - - - - - 150 270 360 135 135 - 100 150 378 504 189 189 - 375 150 756 882 315 441 63 375 150 441 0 1008 Fixing on support sheet (only for E1.2) Y Ø10 MAX M4x8 screws supplied Tightening torque 1.5Nm B [mm] 100 Ø 9 Y 80 (III) 80 150 (IV) ABB Catalogue | 1SDC200023D0201 | 7/19 Emax2_cap07.indd 19 15/04/2013 17:55:59 Dimensions Withdrawable circuit-breaker - E1.2 Rear orientable terminals - HR/VR 348 (IV) 8 278 (III) Y 155.5 2 3 363.5 25 15 Ø 11 343 X X 12.5 33 39 159.5 = 44 = = 44 = Y Terminals HR 271 251 10 7 7 2 29 2 15 70 7 236.5 X 4 X 2 Y 213 Y 2 57.5 70 70 N L1 L2 L3 2 3 53 5 49 100 15 42 Terminals VR 271 251 10 7 2 29 3 7 236.5 X X 70 70 Y 70 15 198 N L1 Y L2 3 L3 60.5 57.5 5 49 100 15 42 3 4 2 3 4 Horizontal rear terminals Vertical rear terminals Tightening torque 12 Nm 5 Door position - Ref. page 7/18 7 Rear segregation for rear terminals 10 Isolating distance 1SDC200608F001 Key 7/20 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 20 15/04/2013 17:56:00 Extended front terminals – EF 348 (IV) 271 278 (III) 8 Y 15 251 155.5 8 15 1 10 Y 2 III - 342 IV - 456 20 202 343 1 115 Ø 6.5 236.5 X X 50 30 239.5 363.5 8 193.5 8 X X III - 206 IV - 276 X 99.5 363.5 199 230 X 460 109.5 159.5 103 57.5 5 4 49 Y 6 42 6 4 100 Y III - 219 IV - 289 6 15 203 1 25 1 12.5 12.5 Ø 11 = 44 12.5 = 44 = 73 25 7 15 73 200 12.5 Rear terminals for cables – FcCuAl 348 (IV) 278 (III) 271 155.5 10 Y 343 x 251 2 17.5 x 363.5 236.5 2 70 81.5 x 95 2 x 10 7 159.5 2 70 7.5 Y 57.5 Y Y 3 5 49 N L1 L2 L3 100 15 7 42 67.5 2 17.5 10 17.5 37.5 110 37.5 17.5 Ø 14.5 1 2 3 Front terminals Rear terminals for cables Tightening torque 48 Nm 4 5 6 Tightening torque 12 Nm Door position - Ref. page 7/18 Rear segregation for front terminals 7 Rear segregation for rear terminals 8 Insulating protection 10 Isolating distance 1SDC200609F001 Key ABB Catalogue | 1SDC200023D0201 | 7/21 Emax2_cap07.indd 21 15/04/2013 17:56:01 Dimensions Withdrawable circuit-breaker - E1.2 Front spread terminals - ES 3-pole version 114 271 5 114 22 3 15 2 Y 15 251 1 15 8 5 1 2 324 324.5 X 363.5 343 X 236.5 X X 159.5 57.5 4 6 49 42 Y 6 100 15 155.5 188 278 7 1 1 = 88 = 45 = 88 = 22.5 Ø 13 = 88 = 1 45 22.5 Ø 13 20 15 45 22.5 Ø 13 20 20 116.5 132 4-pole version 114 114 271 5 114 22 3 15 2 Y 15 251 1 15 8 5 1 2 324.5 324 343 X X 363.5 236.5 X X 159.5 57.5 = 88 = 45 4 Y 49 42 6 100 15 155.5 188 348 = 88 = 1 15 45 1 Ø 13 1 = 88 = 45 = 88 = 22.5 Ø 13 15 45 22.5 Ø 13 Ø 13 20 20 = 88 = 1 45 22.5 22.5 20 20 116.5 116.5 132 132 1 2 3 Splayed terminal Tightening torque 40 Nm Front terminal 4 5 Door position - Ref. page 7/18 Insulating protection (refer to front terminals page 7/21 6 8 Rear segregation for front terminals Isolating distance 1SDC200610F001 Key 7/22 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 22 15/04/2013 17:56:03 Horizontal rear spread terminals – SHR 348 (IV) 278 (III) Y 155.5 = 60 = 1 60 2 15 42.5 12.5 25 25 343 x 363.5 x 36 2.5 39 83 25 159.5 15 19.5 9.5 83 28.75 25 20 Ø 11 25 25 = 44 = Y 3-pole version 271 7 90 3 1 2 251 2 7 15 90 236.5 x x 243 90 1 Y 5 1 121.5 57.5 Y L1 L2 L3 100 49 4 5 15 42 4-pole version 271 7 90 3 1 2 251 2 15 90 90 10 5 236.5 x x 90 2 Y 2 243 121.5 Y N L1 L2 L3 57.5 100 49 4 15 5 42 1 2 3 Splayed rear terminals for 3-pole version Splayed rear terminals for 4-pole version Tightening torque 18 Nm 4 5 7 Door position - Ref. page 7/18 Rear segregation of rear terminals Isolating distance 1SDC200611F001 Key ABB Catalogue | 1SDC200023D0201 | 7/23 Emax2_cap07.indd 23 15/04/2013 17:56:04 Dimensions Withdrawable circuit-breaker - E2.2 Rear orientable terminals - HR/VR E2.2 B/N/S/H 2000A E2.2 N/S/H 2500A 383 317 (III) 47 7 158.5 13 14 15 14 407 (IV) 1 Y 12 47 47 10 425 X X 4 351 X X 124 X X 1 2 4 430 114 47 10 X X 114 X X 2 4 430 114 8 185.5 3 118 Ø 5.45 123 123 123 34 Y 75 150 34 5 6 74.5 5 351 366 7 13 1 10 3 6 5 6 E2.2 B/N/S/H 2000A 331 (III) / 421(IV) 35 12 Ø 13 90 90 4 Y 45 N = 60 = 1 2 90 14 33 3 165.5 1 3 10 Y L2 L1 L3 3 4 = 50 = 2 90 90 14 90 Y N Y L2 L1 L3 E2.2 N/S/H 2500A 331 (III) / 421(IV) 165.5 1 3 35 Ø 13 90 2 1 90 Y 14 30 12 90 10 33 N 45 4 = 60 = = 60 = 90 90 L3 90 Y 14 3 4 Y L2 L1 N L1 Y L2 L3 1 2 3 4 Horizontal terminals 2000A Vertical terminals 2000A Horizontal terminals 2500A Vertical terminals 2500A 5 6 7 8 Tightening torque 2000A 8.6Nm Tightening torque 2500A 8.6Nm Door position - Ref. page 7/19 Earthing device 12 13 14 15 Mobile part Fixed part Segregation (where envisaged) Distance from connected for testing to isolated 1SDC200612F001 Key 7/24 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 24 15/04/2013 17:56:06 Front terminals – F 34 407 (IV) 317 (III) 158.5 20 15 Y 11 1 4 10 3 9 425 521 X 351 X X X X X 3 5 185.5 Ø 5.45 13 Y 15 34 2 50 150 225 224.5 34 215 141 20 155 Upper front terminals 7 1 1 2 1 2 264 15 Ø 13 90 90 90 Y 35 60 N L1 Y L2 L3 Lower front terminals 2 203 15 Ø 13 35 60 1 2 3 4 Upper front terminals Lower front terminals Tightening torque 8.6Nm Door position - Ref. page 7/19 5 9 10 11 Earthing device Mobile part Fixed part Distance from connected for testing to isolated 1SDC200613F001 Key ABB Catalogue | 1SDC200023D0201 | 7/25 Emax2_cap07.indd 25 15/04/2013 17:56:06 Dimensions Withdrawable circuit-breaker - E2.2 Horizontal rear spread terminals – SHR E2.2 B/N/S/H 2000A 14 407 (IV) 13 E2.2 N/S/H 2500A 317 (III) 12 14 383 158.5 14 7 Y 1 2 69 10 X 425 X 351 X X 10 X 124 8 185.5 34 Ø 5.45 3 4 69 X 114 123 118 Y 150 215 141 5 202 225 15 202 6 351 E2.2 B/N/S/H 2000A 7 1 = 60 = 10 35 15 331 55 1 165.5 67 130 2 4 130 1 3 Y 60 100 = 45 = Y L2 L1 L3 14 421 165.5 35 2 10 2 4 15 55 67 Y L2 L1 L3 407 (IV) 13 = 45 = 1 3 130 Y N = 60 = 90 130 2 14 E2.2 N/S/H 2500A 3 = 60 = 30 35 3 10 15 331 55 165.5 67 130 2 4 130 1 3 Y 60 100 = 60 = Y L2 L1 L3 14 421 4 165.5 30 35 2 4 10 90 130 15 55 67 = 60 = N 13 = 60 = 1 3 130 Y L1 Y L2 407 (IV) L3 4 14 331 1 2 3 4 Side horizontal splayed terminals 2000A Central horizontal splayed terminals 2000A Side horizontal splayed terminals 2500A Central horizontal splayed terminals 2500A 5 6 7 8 Tightening torque 2000A 8.6Nm Tightening torque 2500A 8.6Nm Door position - Ref. page 7/19 Earthing device 12 Mobile part 13 Fixed part 14 Segregation (where envisaged) 1SDC200614F001 Key 7/26 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 26 15/04/2013 17:56:08 Vertical rear spread terminals – SVR E2.2 B/N/S/H 2000A E2.2 N/S/H 2500A 11 407 (IV) 317 (III) 10 158.5 13 383 5 12 12 Y 1 2 69 425 X X 430 X X 351 X X 194 6 185.5 Ø 5.45 34 83 Y 150 13 215 141 3 4 202 215 225 34 224.5 351 E2.2 B/N/S/H 2000A 7 1 = 60 = 1 10 35 12 15 55 90 90 Y 67 Y L2 L1 N 60 100 1 90 L3 = 45 = E2.2 N/S/H 2500A 2 = 60 = 30 35 331(III)/421(IV) 12 15 55 2 165.5 10 90 90 2 90 Y 67 N L1 Y L2 L3 60 100 = 60 = 1 2 3 4 Vertical splayed terminals 2000A Vertical splayed terminals 2500A Tightening torque 2000A 8.6Nm Tightening torque 2500A 8.6Nm 5 6 10 11 Door position - Ref. page 7/19 Earthing device Mobile part Fixed part 12 Segregation (where envisaged) 13 Distance from connected for testing to isolated 1SDC200615F001 Key ABB Catalogue | 1SDC200023D0201 | 7/27 Emax2_cap07.indd 27 15/04/2013 17:56:09 Dimensions Withdrawable circuit-breaker - E4.2 Rear orientable terminals - HR/VR E4.2 N/S/H 3200A 383 551 (IV) 212.5 12 15 14 425 (III) 13 E4.2 N/S/H 4000A E4.2 V 2000...4000A 14 7 47 425 47 Y 351 X X X 47 2 4 2 4 47 20 X X X 154 430 134 X X 430 184 X X 4 184 8 185.5 103 Ø 5.45 113 113 5 6 5 6 113 34 Y 13 10 75 1 150 351 366 34 74.5 3 6 5 E4.2 N/S/H 3200A 7 439 (III) / 565 (IV) 1 3 1 2 35 20 14 12 33 219.5 126 126 Y 126 1 2 Y 45 N L1 L3 L2 Ø 13 = 80 = 2 = 70 = 126 126 126 Y 14 Y 4 N L1 L2 L3 E4.2 N/S/H 4000A E4.2 V 2000...4000A 439 (III) / 565 (IV) 1 3 35 50 12 3 4 Ø 13 14 10 33 219.5 126 126 Y 126 3 4 Y 45 10 = 80 = 4 = 80 = N L1 L2 L3 N L1 L2 L3 126 126 Y 126 14 Y N L1 L2 L3 1 2 3 4 Horizontal terminals 3200A Vertical terminals 3200A Horizontal terminals 4000A Vertical terminals 4000A 5 6 7 8 Tightening torque 3200A 20Nm Tightening torque 4000A 20Nm Door position - Ref. page 7/19 Earthing device 12 13 14 15 Mobile part Fixed part Segregation (where envisaged) Distance from connected for testing to isolated 1SDC200616F001 Key 7/28 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 28 15/04/2013 17:56:11 Front terminals – F 551 (IV) 425 (III) Y 212.5 15 383 4 1 20 11 3 425 X 521 X X 351 X 3 4 X X 5 185.5 Ø 5.45 2 10 Y 15 13 10 45 9 75 150 291 34 20 34 74.5 380 Upper front terminals 7 1 1 269 15 Ø 13 126 35 126 126 Y 80 2 Y N L1 L2 L3 Lower front terminals 2 2 198 15 Ø 13 35 80 1 2 3 Upper front terminals Lower front terminals Tightening torque 20Nm 4 5 9 Door position - Ref. page 7/19 Earthing device Mobile part 10 Fixed part 11 Distance from connected for testing to isolated 1SDC200617F001 Key ABB Catalogue | 1SDC200023D0201 | 7/29 Emax2_cap07.indd 29 15/04/2013 17:56:12 Dimensions Withdrawable circuit-breaker - E6.2 Horizontal rear terminals – HR E6.2 H/V 5000A E6.2 H/V 6300A E6.2 X 5000...6300A 929 (IV) 464.5 (IV) 383 803 (III) 11 10 12 338.5 (III) Y 47 47 10 20 425 X X 6 X X X 154 X 184 Ø 5.45 185.5 Y 113 103 5 34 10 75 150 351 366 1 2 3 4 E6.2 H/V 5000A 7 817 1 2 35 1 252 20 12 45 L1 L2 189 Ø 13 252 L3 252 Y 12 = 70 = Y 943 1 2 = 80 = 1 252 63 III 33 Y 12 IV N Y L1 63 L2 L3 E6.2 H/V 6300A E6.2 X 5000...6300A 2 35 252 Y 12 50 2 817 1 2 252 63 10 12 III 33 45 = 80 = = 80 = 189 Y 252 L3 252 Y 12 IV L2 943 1 2 10 Ø 13 L1 N L1 Y 63 L2 L3 1 2 3 4 Horizontal terminals 5000A Horizontal terminals 6300A Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm 5 Door position - Ref. page 7/19 6 Earthing device 10 Mobile part 11 Fixed part 12 Segregation (where envisaged) 13 Distance from connected for testing to isolated 1SDC200618F001 Key 7/30 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 30 15/04/2013 17:56:13 Vertical rear terminals – VR E6.2 H/V 5000A E6.2 H/V 6300A E6.2 X 5000...6300A 929 (IV) 464.5 (IV) 383 803 (III) 11 10 Y 383 12 5 338.5 (III) X 425 X 6 X 12 5 1 2 47 X 47 6 X 134 X 1 2 184 185.5 113 113 Y 34 10 75 150 75 3 4 351 A 366 34 10 150 351 366 3 4 E6.2 H/V 5000A 7 1 1 35 33 817 252 3 20 12 III 45 = 80 = L1 = 70 = 1 252 12 L2 Y L3 943 1 Ø 13 Y 63 189 252 3 252 IV N Y L1 12 63 Y L2 L3 E6.2 H/V 6300A E6.2 X 5000...6300A 817 2 2 35 50 12 33 252 4 10 2 252 63 Y 12 III L1 45 L2 Y L3 943 Ø 13 = 80 = 10 = 80 = 2 189 252 4 252 12 63 Y IV N L1 Y L2 L3 1 2 3 4 Vertical terminals 5000A Vertical terminals 6300A Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm 5 Door position - Ref. page 7/19 6 Earthing device 10 Mobile part 11 Fixed part 12 Segregation (where envisaged) 13 Distance from connected for testing to isolated 1SDC200619F001 Key ABB Catalogue | 1SDC200023D0201 | 7/31 Emax2_cap07.indd 31 15/04/2013 17:56:14 Dimensions Withdrawable circuit-breaker - E6.2 Rear orientable terminals - HR/VR full size E6.2 H/V 5000A 12 E6.2 H/V 6300A E6.2 X 5000...6300A 383 1055 7 464.5 Y 14 47 425 47 20 13 8 X X X X X 154 X 42 184 Ø 5.45 185.5 113 103 Y 11 34 10 75 150 351 366 1 3 5 6 E6.2 H/V 5000A 7 1 3 1 2 1069 252 35 33 252 14 20 12 45 252 63 Y N Y L1 L2 L3 Ø 13 = 80 = = 70 = 2 1069 252 252 14 252 Y 63 N Y L1 L2 L3 E6.2 H/V 6300A E6.2 X 5000...6300A 1 3 3 4 35 50 12 33 Ø 13 1069 252 10 45 Y Y L1 4 = 80 = 252 63 N 10 = 80 = 252 14 L2 L3 1069 252 252 252 Y 63 14 N L1 Y L2 L3 1 2 3 4 Horizontal terminals 5000A Vertical terminals 5000A Horizontal terminals 6300A Vertical terminals 6300A 5 6 7 8 Tightening torque 5000A 20Nm Tightening torque 6300A 20Nm Door position - Ref. page 7/19 Earthing device 12 Mobile part 13 Fixed part 14 Segregation (where envisaged) 1SDC200620F001 Key 7/32 | 1SDC200023D0201 | ABB Catalogue Emax2_cap07.indd 32 15/04/2013 17:56:15 Front terminals – F 1055 (IV FS) 929 (IV) 803 (III) 338.5 (III) 383 276 15 Y 4 138 11 1 20 1 3 521 X 425 X 351 X X X 185.5 Y 15 10 75 464.5 (IV/IV FS) 20 150 5 X Ø 5.45 3 45 9 10 2 34 2 13 291 74.5 380 34 Upper front terminals Lower front terminals 1 2 269 198 Ø 13 15 35 80 35 189 63 252 L2 Y 252 80 252 252 63 Y Y L1 15 Ø 13 252 252 7 Y Y L3 N 3-pole L1 L2 4-pole L3 N L1 Y 252 63 L2 L3 4-pole full size 1 2 3 Upper front terminals Lower front terminals Tightening torque 20Nm 4 5 9 Door position - Ref. page 7/19 Earthing device Mobile part 10 Fixed part 11 Distance from connected for testing to isolated 1SDC200621F001 Key ABB Catalogue | 1SDC200023D0201 | 7/33 Emax2_cap07.indd 33 15/04/2013 17:56:16 Emax2_cap07.indd 34 15/04/2013 17:56:17 Electrical diagrams Reading information Circuit-breakers 8/2 ATS021 and ATS022 8/7 Power controller 8/8 Circuit-breakers 8/9 Terminal box E1.2 8/10 Terminal box E2.2 - E4.2 - E6.2 8/11 Electrical accessories 8/12 ATS021 and ATS022 8/38 8 ABB Catalogue | 1SDC200023D0201 | 8/1 Emax2_cap08.indd 1 12/04/2013 14:05:50 Electrical diagrams Reading information – Circuit-breakers Operating state shown The diagram is shown in the following conditions: - withdrawable version circuit-breaker, open and racked-in - with de-energized circuits - trip units not tripped - motor operator with unloaded springs. Versions The diagram shows a withdrawable version circuit-breaker, but it is also valid for fixed version circuit-breakers. Fixed version The control circuits are included between the XV terminals (the X connector is not supplied). Withdrawable version The control circuits are included between the poles of the X connector (the XV terminal box is not supplied). 8 Description of figures 1) Supplementary open/closed auxiliary contacts of the circuit-breaker (second set) 2) Ekip Signalling 4K 11) Trip signalling contact 12) Contact for signalling position of loaded springs 13) Motor for loading closing springs- M 14) Trip reset coil - YR 20) Ekip Measuring/Measuring Pro with voltage socket inside the four pole circuit-breaker 21) Ekip Measuring/Measuring Pro with voltage sockets inside the three-pole circuit-breaker and connection for external neutral 22) Ekip Measuring Pro for residual voltage protection (for Ekip G only) 23) Ekip Measuring/Measuring Pro with external voltage socket 24) Rc residual current protection sensor input 25) Transformer star centre sensor input 26) Zone selectivity 27) Current sensor input on external neutral (only for 3-pole circuit-breakers) 31) Direct auxiliary supply 24V DC and local bus 32) Auxiliary supply through module 110-240V AC/DC or 24-48V DC and local bus 33) Ekip Fan 24V DC 41) Ekip signalling 2K-1 42) Ekip signalling 2K-2 43) Ekip signalling 2K-3 48) Ekip sinchrocheck 51) Ekip COM Modbus RS-485 52) Ekip COM Modbus TCP 53) Ekip COM Profibus 54) Ekip COM Profinet 55) Ekip COM DeviceNet 56) Ekip COM EtherNet IP 57) Ekip COM IEC61850 58) Ekip LINK 61) Ekip COM R Modbus RS-485 Redundant 62) Ekip COM R Modbus TCP Redundant 63) Ekip COM R Profibus Redundant 8/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 2 12/04/2013 14:05:50 64) Ekip COM R Profinet Redundant 65) Ekip COM R DeviceNet Redundant 66) Ekip COM R EtherNet IP Redundant 71) Contact ready to close - RTC 72) Second opening coil - YO2 73) Undervoltage coil - YU 74) Undervoltage coil with external time-lag device - YU, D 75) First opening coil - YO 76) First opening coil with control from protection trip unit - YO, Ekip Com Actuator 77) First closing coil - YC 78) First closing coil with control from protection trip unit - YC, Ekip Com Actuator 79) Second closing coil - YC2 81) Open/closed auxiliary contacts of circuit-breaker (first set) 91) External supplementary open/closed auxiliary contacts of circuit-breaker 95) Contacts for signalling circuit-breakers in racked-in, test, racked-out position 96) Contacts for signalling circuit-breakers in racked-in, test, racked-out position (first set) 97) Supplementary contacts for signalling circuit-breakers in racked-in, test, racked-out position (second set) 98) Circuit-breakers without auxiliary safety voltage 99) Circuit-breakers with auxiliary safety voltage in direct and alternating current 100) ATS021 101) ATS022 102) Third circuit-breaker controlling with ATS022 103) Ekip Signalling 10K 104) Ekip Multimeter 105) Application diagram for Ekip Touch, Hi-Touch, G Touch, G Hi-Touch with Power Controller function. 8 ABB Catalogue | 1SDC200023D0201 | 8/3 Emax2_cap08.indd 3 12/04/2013 14:05:50 Electrical diagrams Reading information – Circuit-breakers 8 Key * A1 A3 A4 BUS1 D F1 GZi(DBi) GZo(DBo) I O1…32 K51 = = = = = = = = = = = K51/COM K51/FAN K51/MEAS K51/SIGN K51/SUPPLY K51/SYNC K51/YC K51/YO M M2 O 01...32 O SC Q Q/1...Q/25 Q/26...Q/27 RC RT1…RT3 RTC EKIP RTC S33M/1…2 S43 S51 S75E/1…4 S75I/1…5 S75T/1…2 SC SO SO1 SR SZi(DFi) SZo(DFo) TI/L1 TI/L2 TI/L3 TI/N TU1…TU2 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = See the note indicated by the letter Applications located on the mobile part of the circuit-breaker Applications located on the fixed part of the circuit-breaker Indicative devices and connections for control and signalling, outside the circuit-breaker Serial interface with external bus Electronic time-lag device of YU undervoltage coil, outside the circuit-breaker Time-delayed trip fuse Zone selectivity input for G protection or input in “reverse” direction for D protection Zone selectivity output for G protection or output in “reverse” direction for D protection Programmable digital inputs of the EKIP protection trip unit Electronic overcurrent protection trip unit of the types: EKIP DIP, EKIP TOUCH, EKIP LCD, EKIP HI-TOUCH , EKIP HI-LCD, EKIP G TOUCH, EKIP G LCD, EKIP G HI-TOUCH , EKIP G HI-LCD Communication module Ventilation supply module Measurement module Signalling module Optional auxiliary supply module (110-220VAC/DC and 24-48VDC) Synchronization module Closing control from the EKIP protection trip unit Opening control from the EKIP protection trip unit Motor for loading closing springs Motor for fans Programmable signalling contacts of the EKIP protection trip unit EKIP protection trip unit contact for synchronism control Circuit-breaker Auxiliary contacts of circuit-breaker Auxiliary open/close contacts used internally by the trip unit RC (residual current) protection sensor Temperature sensors Auxiliary ready to close contact of circuit-breaker, used internally by the trip unit Contact for signalling circuit-breaker is ready to close Limit contacts of spring loading motor Switch for presetting remote/local control Trip signalling contact Contacts for signalling circuit-breaker in racked-out position (provided only with withdrawable version) Contacts for signalling circuit-breaker in racked-in position (provided only with withdrawable version) Contact for signalling circuit-breaker in test position (provided only with withdrawable version) Pushbutton or contact for closing the circuit-breaker Pushbutton or contact for immediate opening of the circuit-breaker Pushbutton or contact for opening the circuit-breaker with time-delayed trip Pushbutton or contact for electrical resetting of S51trip contact Input for zone selectivity for S protection or input in “direct” direction for S protection Output for zone selectivity for S protection or output in “direct” direction for D protection Current transformer phase L1 Current transformer phase L2 Current transformer phase L3 Current transformer on neutral Insulation voltage transformer (outside circuit-breaker) 8/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 4 12/04/2013 14:05:50 Uaux UI/L1 UI/L2 UI/L3 UI/N UI/O W2 W9…W13 W9R.W11R X XB1...XB7 XF XF1…XF2 XK1…XK3 XK7 XV YC YC2 YO YO1 YO2 YR YU = = = = = = = = = = = = = = = = = = = = = = = Auxiliary supply voltage Current sensor phase L1 Current sensor phase L2 Current sensor on phase L3 Current sensor on neutral Single-pole current sensor Serial interface with internal bus (local bus) RJ45 connector for communication modules RJ45 connector for redundant communication modules Delivery connector for auxiliary circuits for withdrawable version of circuit-breaker Connectors for circuit-breaker applications Delivery terminal board for position contacts of withdrawable version of circuit-breaker Contact of the EKIP protection trip unit for activating fans Connectors for auxiliary circuits of the EKIP protection trip unit Connector for auxiliary circuits of communication module Delivery terminal box for auxiliary circuits of fixed version circuit-breaker Closing coil Second closing coil Opening coil Opening coil for overcurrent Second opening coil Coil for electrical resetting of trip contact S51 Undervoltage coil 8 ABB Catalogue | 1SDC200023D0201 | 8/5 Emax2_cap08.indd 5 12/04/2013 14:05:50 Electrical diagrams Reading information – Circuit-breakers 8 Notes A) Auxiliary supply for Ekip trip unit is mandatory ( refer to diagram 1SDM00009R0001 figures 31 - 32- 33 - 34). C) Always supplied with Ekip Com module. D) Always supplied with motor for loading closing springs in Fig. 13. E) Obligatory voltage transformer in the case of external sockets. Obligatory external sockets for systems with rated voltage greater than 690V. F) The connections between the RC residual current protection sensor and the poles of the X connector (or XV) of the circuitbreaker must be made with 4-pole shielded cable with conductors interwoven in pairs (type BELDEN 9696 paired or equivalent), of a length no greater than 10 m. The shield should be earthed on circuit-breaker side. G) With all electronic protection trip units equipped with display interface with LSIG protections, protection against an earth fault is available (Gext) by means of current sensor positioned on the star centre of the MV/LV transformer. The connection between terminals 1 and 2 of the UI/O current transformer and Ge+ and Ge- poles of the X connector (or XV) must be made with shielded and stranded 2-pole cable (type BELDEN 8762/8772 or equivalent) of length no greater than a 15 m. The shield should be earthed on the circuit-breaker side and current sensor side. H) The connection between the terminal box and external neutral sensor must be made with the 2m cable provided. The Ne+ and Ne- poles of the X connector (or XV) must be short-circuited if no sensor is present on the external neutral conductor. I) Obligatory in the case of the presence of any Ekip module. J) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-34. N.B.: Ekip Fan 24VDC occupies in the terminal box the space of the Ekip Supply and one slot Module. K) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-33. K) Only for E2.2, E4.2 and E6.2 withdrawable version circuit-breakers as an alternative to Fig. 31-32-33. N.B.: Ekip Fan 220VAC occupies in the terminal box the space of the Ekip Supply and two slot Modules. L) In the presence of Fig. 32, for E2.2, E4.2 and E6.2 circuit-breakers up to three applications between Fig. 41…58 taken only once can be supplied, instead for E1.2 circuit-breakers, up to two applications between Fig. 41…58 taken only once can be supplied. The Ekip Com module selected can be duplicated if required, by choosing between Fig. 61…66. M) In the presence of Fig. 33, for E2.2, E4.2 and E6.2 circuit-breakers, up to two applications between Fig. 41…58 taken only once can be supplied. The Ekip Com module selected can be duplicated if required, by choosing between Fig. 61…66. N) In the presence of Fig. 34, for E2.2, E4.2 and E6.2 circuit-breakers, a single application between Fig. 41…58 can be supplied. O) In the presence of several Ekip Com modules with withdrawable version circuit-breakers, the contact S75I/5 should be connected only once to a single module. P) The auxiliary voltage Uaux. enables activation of all the functions of the EKIP electronic protection trip units. Since an earth insulated Uaux was requested, it is necessary to use “galvanically separated convertors” which comply with the standards IEC 60950 (UL 1950) or equivalent, which guarantee a common mode current or leakage current (refer to IEC 478/1, CEI 22/3) no greater than 3.5mA, IEC 60364-41 and CEI 64-8. Q) Regarding local bus the maximum cable lenght is 15m. 8/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 6 12/04/2013 14:05:50 Electrical diagrams Reading information – ATS021 and ATS022 Operating state shown The diagram is shown in the following conditions: - circuit-breakers open and racked-in # - with de-energized circuits - trip units not tripped * - unloaded closing springs. Key A CB1-N CB2-E K1 K2 KC1-KC2 KO1-KO2 M Q/1 Q60 Q61/1-2 S11 S11...S15 S1-S2 S3 S33M/1 S51 S75I/1 BUS 1 X XF XV YC YO = = = = = = = = = = = = = = = = = = = = = = = = ATS021 and ATS022 devices for automatic switching of two circuit-breakers Normal supply line circuit-breaker Emergency supply line circuit-breaker Auxiliary contactor type NF22E for voltage presence of normal power supply Auxiliary contactor type NF22E for voltage presence of emergency power supply Auxiliary contactors type AL__-30 for the closing of the circuit-breakers Auxiliary contactors type AL__-30 for the opening of the circuit-breakers Motor for loading the closing springs Auxiliary contact of the circuit-breaker Thermal relay for isolating and protecting the auxiliary circuits of safety auxiliary voltage Thermal relays for isolating and protecting the auxiliary circuits of the lines Contact for enabling automatic switching of the ATS021 device Signalling contacts for the inputs of the ATS022 device Contacts controlled by the cam of the motor operator Changeover contact for electrical signalling of local/remote selector state Limit contacts of spring loading motor Contact for electrical signalling of circuit-breaker open due to tripping of overcurrent trip unit Contact for signalling circuit-breaker racked-in # Serial interface with control system (MODBUS EIA RS485 interface) available with the device ATS022 Connector for auxiliary circuits of withdrawable version circuit-breakers Delivery terminal box for the position contacts of the circuit-breaker Delivery terminal box for the auxiliary circuits of the fixed version circuit-breakers Shunt closing release Shunt opening release 8 # This diagram shows the withdrawable version circuit-breakers, but it is also valid for the fixed version circuit-breakers. In this case, it is not necessary to connect the S75I/1 contacts on the X31:1 input of the ATS021 device otherwise it is necessary to connect the X32:5 and X32:6 terminals with the terminal X32:9 of the ATS022 device. * This diagram shows circuit-breakers with overcurrent release but it is also valid for circuit-breakers without release (switchdisconnectors). If the S51 contact is not present, the S51contacts on the X31:1 input of the ATS021 device should not be considered, while it is necessary to connect the X32:7 and X32:8 terminals with the X32:9 terminal of the ATS022 device. ABB Catalogue | 1SDC200023D0201 | 8/7 Emax2_cap08.indd 7 12/04/2013 14:05:50 Electrical diagrams Reading information – Power Controller Operating state shown The diagram is shown in the following conditions: - circuit-breaker, open and racked-in # - with de-energized circuits - trip units not tripped * - motor operator with unloaded springs. 8 Key A13 A17 A21 Fl I 01 ... 12 J .. K51 K51/COM K51/SIGN K51/SUPPLY K51/YC K51/YO M M O 01 ... 12 Q/1 Q1 Q2 Q3 Q4 R1 S33M/1 S51 S75I/5 W13 X XV YC YO = = = = = = = = = = = = = = = = = = = = = = = = = = = = = EKIP SIGNALLING 10K unit MOE actuator unit for stored energy operating mechanism for the Tmax XT circuit-breaker EtherNet Switch device Time-delayed trip fuse Programmable digital inputs of the EKIP protection trip unit Connectors for auxiliary circuits of the Tmax XT circuit-breaker in the withdrawable version Electronic overcurrent protection trip unit type EKIP for EMAX 2 circuit-breaker type Communication module for the EKIP trip unit Signalling module for EKIP trip unit Optional auxiliary supply module for the EKIP trip unit Closing control from the EKIP protection trip unit Opening control from the EKIP protection trip unit Motor for loading closing springs for EMAX 2 circuit-breaker type Motor for opening the circuit-breaker and for loading closing springs for TMAX XT circuit-breaker type Programmable signalling contacts of the EKIP protection trip unit Auxiliary contacts of circuit-breaker Emax 2 circuit-breaker equipped with EKIP POWER CONTROLLER Emax 2 circuit-breaker Tmax XT circuit-breaker equipped with MOE actuator unit Emax 2 MS switch-disconnector Resistor Limit contacts of spring loading motor Trip signalling contact Contacts for signalling Emax 2 circuit-breaker in racked-in position (provided only for withdrawable version) RJ45 connector for communication modules Delivery connector for auxiliary circuits for withdrawable version of Emax 2 circuit-breaker Delivery terminal box for auxiliary circuits of fixed version circuit-breaker Closing coil Opening coil 8/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 8 12/04/2013 14:05:50 Electrical diagrams Circuit-breakers 3-pole or 4-pole circuit-breaker A UPPER N L1 L2 L3 K51 XK1 1 Q T11 A1 XK1 13 TI/L1 T12 T21 11 TI/L2 T22 12 T31 9 TI/L3 T32 10 T41 7 TI/N T42 8 XK1 21 T13 UI/L1 UI/L2 UI/L3 UI/N > YO1 14 T14 22 T23 19 T24 20 T33 17 T34 18 T43 15 T44 16 >> 2 XK3 >> 7 Q/26 >> > >> 8 XK3 9 Q/27 EKIP DIP EKIP TOUCH EKIP HI-TOUCH EKIP LCD EKIP HI-LCD EKIP G TOUCH EKIP G HI-TOUCH EKIP G LCD EKIP G HI-LCD 10 XK3 5 RTC EKIP 6 * C) 8 LOWER 3-pole or 4-pole switch-disconnector B N L1 L2 L3 A1 1SDC200622F001 Q ABB Catalogue | 1SDC200023D0201 | 8/9 Emax2_cap08.indd 9 12/04/2013 14:05:50 Electrical diagrams Terminal box E1.2 LOCAL BUS K51/MEAS VN 23 L1 L2 L3 14 M 13 44 Q4 Q1 34 24 Q2 C2 C12 14 Q3 YO RTC YU YC YO2 42 32 31 D2 Module Module and/or communication modules 51 .. .. 58 and/or redundant communication modules 61 .. .. 66 R2 S33M/1 S33M/2 11 S51 Trip Unit I/O Transformer star centre sensor input 26 RC residual current protection sensor input 25 Ekip Measuring voltage sockets 24 20 21 22 23 U1 U2 12 27 VN V1 V2 V3 R1 F1 Zone selectivity 36 38 35 96 98 95 14 13 12 Trip signalling contact 11 YR reset trip coil Closing springs loading motor Contact for signalling position of loaded springs 1SDC200623F001 K51/MEAS 21 22 Szi Szo Gzi Gzo Szc V1 Gzo Szc Gzi K51/MEAS 48 YR 24 and/or Ekip synchro check .. 66 26 Rct Rca Ge+ Ge- 41 42 43 M K31 K51 N L1 L2 L3 31 32 Signalling modules U2 K33 W..R YR K51 20 Auxiliary supply and local bus 38 I 31 61 .. K51/COM K32 K51/SIGN .. K51 25 71 58 98 K34 K51/SIGN HC3 Ge + Ge – Current sensor input on external neutral S51 S33 I 32 K21 Szi K23 Szo I 21 W.. Vn Ge K24 Rct Ge I 22 K51/SIGN 51 .. K51/COM K22 V3 K51/SIGN V2 H31 73 74 VS1 VS2 R1 O 32 H32 Vs K11 R2 K51/SIGN O 31 K51/SIGN 72 Ready to close contact K51/SYNC HC2 43 75 76 Second opening coil or undervoltage coil 48 U1 H21 K13 First closing coil KS2 36 H22 I 11 KS1 O SC 35 O 22 K51/SIGN O 21 K51/SIGN K14 K51/SIGN HC1 42 K51/SYNC K12 I 12 K1 K2 96 H11 K51/SIGN PORTA COMUNIC. COMMUN. PORT K51/SIGN H12 W3 W4 ALIM. AUS. +/L AUX. SUPPLY -/N PORTA COMUNIC. COMMUN. PORT RIDONDANTE REDUNDANT K51/SIGN O 11 8 41 O 12 31 32 48 K51/.. Rca 27 K2 Ne+ Ne- W4 K51 45 46 48 45 RTC 71 46 in alternative Ne D1 D1 C2 D2 77 78 TU I/O C3 YC Ne K51 First opening coil EKIP Supply C1 K1 73 74 D1 D2 C12 W3 YO 76 C13 YO 95 72 C11 K51 YC C1 C2 YO2 75 78 YU YO C11 C12 YC 77 81 22 Q/1 n Open/closed auxiliary contacts of circuit-breaker (first set) 21 Q/2 C3 C13 12 Q/3 81 C1 C11 11 42 44 41 32 34 31 22 24 21 12 14 11 Q/4 41 Diagram figure number 8/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 10 12/04/2013 14:05:51 Electrical diagrams Terminal box E2.2 - E4.2 - E6.2 K32 K51/COM I 32 K34 I 31 K33 44 Q4 34 24 Q2 C2 C12 C22 14 YO YC2 Q1 Q3 32 22 D2 48 YU YC RTC YO2 31 21 D1 45 12 TU I/O EKIP Supply Rca K2 Current sensor input on external neutral 71 Auxiliary supply and local bus 31 32 Ventilation control 33 Module Signalling modules 41 42 43 and/or Ekip synchro check 48 and/or communication modules 51 .. .. 58 and/or redundant communication modules 61 .. .. 66 Module Trip Unit I/O V1 Gzo Szc Gzi Szi Vn Ge Zone selectivity 27 Transformer star centre sensor input 26 RC residual current protection sensor input 20 21 22 23 14 13 12 Trip signalling contact 11 Ekip signalling 4K 2 Supplementary auxiliary contacts of circuit-breaker (second set) 1 YR M S51 S33 K5 K8 94 K4 K7 84 EKIP Signalling 4K U2 K6 04 K9 K10 98 38 U1 36 35 96 95 H4 02 01 1 1SDC200624F001 Q/5 in alternative HC Q/6 Q5..Q10 Q/7 K3 Q/8 H3 Q/9 02 04 01 92 94 91 82 84 81 72 74 71 62 64 61 52 54 51 Contact for signalling position of loaded springs 74 K7 Q/10 HC K8 K3 O 01 11 S51 Motor for loading closing springs 64 O 02 K51/SIGN 12 36 38 35 96 98 95 25 24 Ekip Measuring voltage sockets YR reset trip coil 54 K9 K4 U2 S33M/2 92 K5 O 03 K51/SIGN U1 91 K51/SIGN K10 R2 S33M/1 H2 K6 O 04 F1 82 13 M R1 81 K51/SIGN 14 HC 2 75 76 72 Ready to close contact L1 L2 L3 H1 H1 23 VN V1 V2 V3 72 H2 VN 71 H3 K51/MEAS HC H4 Szi Szo Gzi Gzo Szc 62 I 01 I 02 I 03 I 04 N L1 L2 L3 66 26 YR 20 21 22 .. K51 Rct Rca Ge+ Ge- K51/MEAS 61 .. W..R Rct Ge- Szo Ne+ Ne- 58 V2 K31 Module K23 24 K51/MEAS K51/SIGN Second opening coil or undervoltage coil .. I 21 K51 Ge+ Ge- W.. V3 K21 K51/SIGN 51 .. K51/COM K22 61 H31 K51 K51/SIGN 77 78 First closing coil 8 R2 K24 27 K51/SIGN 79 First opening coil VS1 VS2 K51 K51/SIGN Second closing coil 48 52 O 32 I 22 K51/SIGN HC3 25 K2 51 K51/SIGN K13 K51/SIGN H32 O 31 K51/SIGN Vs K11 I 11 K51/SIGN HC2 43 K1 R1 K51/SIGN PORTA COMUNIC. COMMUN. PORT H21 KS1 81 KS2 PORTA COMUNIC. COMMUN. PORT RIDONDANTE REDUNDANT O 12 O 22 K51/SIGN H22 O 21 K51/SIGN W3 ALIM. AUS. AUX. SUPPLY -/N Open/closed auxiliary contacts of the circuit-breaker (first set) 73 74 W4 +/L n K51/SYNC HC1 42 K51/.. XSC K14 D1 46 48 45 RTC K51/SYNC K12 I 12 H11 O 11 K51/SIGN K51/SIGN H12 C2 D2 71 31 32 33 34 K51/SIGN C3 YC W4 in alternative 41 K51 Ne- D2 C1 Ne 73 74 D1 C12 K1 76 C2 YO W3 C1 C13 LOCAL BUS YC 72 78 C12 K51 YC 75 YO2 77 C11 YU YO C11 C21 C22 YO 79 C3 C13 YC2 Q/1 C1 C11 C21 11 Q/2 46 Q/3 81 41 42 44 41 32 34 31 22 24 21 12 14 11 Q/4 42 Diagram figure number ABB Catalogue | 1SDC200023D0201 | 8/11 Emax2_cap08.indd 11 12/04/2013 14:05:51 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 11 21 31 41 12 22 32 42 14 24 34 44 Q1 Q2 Q3 Q4 81) Open/closed auxiliary contacts of circuit-breaker (first set) 81 A4 8 32 34 42 44 32 34 42 44 XV 11 21 31 41 X 11 21 31 41 A4 1SDC200626F001 41 Q/4 31 Q/3 21 Q/2 34 24 22 Q/1 11 A1 44 24 24 42 22 22 32 14 14 14 12 12 12 X XV 8/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 12 12/04/2013 14:05:51 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 45 D1 C1 C11 C21 C3 C13 46 48 YO YC2 Q1 D2 C2 C12 C22 YU YC RTC YO2 YO YC2 77) First closing coil - YC 78) First closing coil with control from protection trip unit - YC, Ekip Com Actuator 79) Second closing coil - YC2 77 78 + ~ + ~ SC SC 79 + ~ A4 SC S43 8 C3 C21 C3 C21 C3 C21 C1 C1 C1 C1 C1 XK7 9 K51 YC A1 XK7 1 XB3 YC XB3 3 YC2 2 XB3 C2 2 C2 XB3 1 XB3 YC 10 4 C22 XB3 K51 Ekip Com Actuator C1 X XV C2 C2 C22 X C2 C2 C22 A4 ~ ~ ~ 1SDC200627F001 XV 77- 78 as an alternative to each other 79 valid only for E2.2 - E4.2 - E6.2 ABB Catalogue | 1SDC200023D0201 | 8/13 Emax2_cap08.indd 13 12/04/2013 14:05:52 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O 45 D1 C1 C11 C21 C3 C13 46 48 YO YC2 Q1 D2 C2 C12 C22 YU YC RTC YO2 YO YC2 75) First opening coil - YO 76) First opening coil with control from protection trip unit - YO, Ekip Com Actuator 75 76 + ~ + ~ SO SO A4 S43 C11 C13 C11 C13 C13 C11 C11 C11 XK7 7 K51 YO A1 XK7 XB4 1 XB4 YO 1 XB4 2 C12 2 XV C12 C12 X C12 C12 A4 ~ 8 YO C12 XB4 K51 Ekip Com Actuator C11 X XV ~ 1SDC200628F001 8 75-76 as an alternative to each other 8/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 14 12/04/2013 14:05:52 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 45 D1 C1 C11 C21 C3 C13 46 48 YO YC2 Q1 D2 C2 C12 C22 YU YC RTC YO2 71) 72) 73) 74) YO YC2 Contact ready to close - RTC Second opening coil - YO2 Undervoltage coil - YU Undervoltage coil with external time-lag device - YU, D 71 72 73 + ~ + ~ 74 + ~ A4 SO SO1 SO SO 8 D1 D1 D1 D1 XB6 48 2 D1 D1 D1 D1 48 48 D1 46 46 46 X XV 3 A1 RTC XB5 1 XB5 YO2 XB5 YU 1 YU 1 45 2 XB5 XV 45 D2 D2 X 45 D2 D2 D2 D2 ~ ~ A4 ~ ~ 2 ~ D + 1SDC200629F001 XB5 D2 2 D2 XB5 D2 XB6 1 72-73 or 74 as an alternative to each other ABB Catalogue | 1SDC200023D0201 | 8/15 Emax2_cap08.indd 15 12/04/2013 14:05:52 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module TU I/O EKIP Supply W3 K1 W4 K2 D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 EKIP Supply 32) Auxiliary supply through module 110-240V AC/DC or 24-48V DC and local bus 32 +/L -/N Uaux. A4 X K1 K2 XV K1 K2 Ekip Supply 110-240VAC/DC Ekip Supply 24-48VDC K51 SUPPLY XV W3 W4 X W3 W4 A4 (H) (L) * Q) W2 (LOCAL BUS) 1SDC200630F001 W4 W3 A3 K2 K1 8 110-240VAC/DC 24-48VDC * I) As an alternative to figures 31-33 8/16 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 16 12/04/2013 14:05:52 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module TU I/O EKIP Supply W3 K1 W4 K2 D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 EKIP Supply 31) Direct auxiliary supply 24V DC and local bus * P) A4 31 + Uaux. 8 24VDC K1 K2 K1 K2 A3 K2 K1 X XV K51 XV W3 W4 X W3 W4 A4 (H) (L) * Q) W2 (LOCAL BUS) 1SDC200631F001 W4 W3 EKIP As an alternative to figures 32-33 ABB Catalogue | 1SDC200023D0201 | 8/17 Emax2_cap08.indd 17 12/04/2013 14:05:52 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module W3 K1 W4 K2 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 EKIP Supply 33) Ekip Fan 24V DC 33 * P) + A4 Uaux. 8 24VDC XF1 XF2 XF3 XF4 XF1 XF2 XF3 XF4 XF4 XF2 K2 4 OF AL Ekip Fan 24VDC OF ON 3 KM2 2 9 1 10 XF3 K2 K2 XF1 K1 K1 K1 X XV K51 FAN A3 KM2 KM1 6 1 W4 W3 M2 XV W3 W4 X W3 W4 A4 (H) (L) * Q) (LOCAL BUS) 2 6 M 7 3 RT1 8 t RT2 4 9 t RT3 5 10 t FAN 1SDC200632F001 5 As an alternative to figures 31-32 8/18 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 18 12/04/2013 14:05:53 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module EKIP Supply TU I/O D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 Module 41) Ekip signalling 2K-1 42) Ekip signalling 2K-2 41 42 A4 8 K23 H21 H22 HC2 K23 H21 H22 HC2 K51 O 21 SIGN K23 O 22 I 22 K24 I 21 Ekip Signalling 2K-2 I 12 K22 K14 I 11 K21 K13 O 12 Ekip Signalling 2K-1 K51 O 11 SIGN K12 A3 HC2 K21 K21 H22 HC1 HC1 H21 H12 H12 HC1 H11 H11 H12 K13 K13 H11 K11 K11 K11 X XV XV K12 K14 K22 K24 X K12 K14 K22 K24 1SDC200633F001 A4 * L), * M), * N) * L), * M), * N) ABB Catalogue | 1SDC200023D0201 | 8/19 Emax2_cap08.indd 19 12/04/2013 14:05:53 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O YO YC2 Q1 Module 43) Ekip signalling 2K-3 48) Ekip sinchrocheck 43 L1 48 TU2 L2 A a B b A4 8 HC3 KS1 VS2 VS1 HC3 KS1 VS2 VS1 VS2 Ekip Synchrocheck I 32 K51 O SC SYNC K34 KS2 I 31 HC3 K33 O 32 Ekip Signalling 2K-3 K51 O 31 SIGN K32 A3 VS1 H32 H32 KS1 H31 H31 H32 K33 K33 H31 K31 K31 K31 X XV XV K32 K34 KS2 X K32 K34 KS2 1SDC200634F001 A4 * L), * M), * N) * L), * M), * N) 8/20 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 20 12/04/2013 14:05:53 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Module 51) Ekip COM Modbus RS-485 52) Ekip COM Modbus TCP 53) Ekip COM Profibus 51 52 53 A4 X 8 XV * O) XK7 n 1 XK7 K51 COM W5 W9 XK7 194 193 2 K51 COM W2 W1 K51 COM 1 2 Ekip Com Profibus XK7 Ekip Com Modbus RS-485 A3 2 Ekip Com Modbus TCP XK7 194 194 1 RJ45 XK7 S75I/5 193 S75I/5 193 S75I/5 * O) W6 * O) XV W1 W2 W5 W6 X W1 W2 W5 W6 (A) (B) BUS 1 * L), * M), * N) 1SDC200635F001 A4 (A) (B) BUS 1 * L), * M), * N) BUS 1 * L), * M), * N) ABB Catalogue | 1SDC200023D0201 | 8/21 Emax2_cap08.indd 21 12/04/2013 14:05:53 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Module 54) Ekip COM Profinet 55) Ekip COM DeviceNet 56) Ekip COM EtherNet IP 54 55 56 A4 X 8 XV * O) XK7 XK7 2 XK7 193 194 194 1 S75I/5 193 S75I/5 193 S75I/5 * O) 1 XK7 2 XK7 194 * O) 1 XK7 2 K51 COM W8 n W7 RJ45 W10 Ekip Com EtherNet IP K51 COM W11 RJ45 K51 COM Ekip Com DeviceNet Ekip Com Profinet A3 n XV W7 W8 X W7 W8 (H) (L) BUS 1 * L), * M), * N) BUS 1 * L), * M), * N) BUS 1 1SDC200636F001 A4 * L), * M), * N) 8/22 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 22 12/04/2013 14:05:54 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Module 57) Ekip COM IEC61850 58) Ekip LINK 57 58 A4 X 8 XV * O) * O) XK7 1 XK7 2 XK7 194 194 193 S75I/5 193 S75I/5 1 XK7 2 RJ45 W12 K51 COM Ekip Link K51 COM W13 RJ45 Ekip Com IEC61850 A3 n n XV X BUS 1 * L), * M), * N) BUS 1 1SDC200637F001 A4 * L), * M), * N) ABB Catalogue | 1SDC200023D0201 | 8/23 Emax2_cap08.indd 23 12/04/2013 14:05:54 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Module 61) Ekip COM R Modbus RS-485 Redundant 62) Ekip COM R Modbus TCP Redundant 63) Ekip COM R Profibus Redundant 61 62 63 A4 X 8 Ekip Com R Profibus K51 COM K51 COM n W6R W9R W5R W2R W1R K51 COM RJ45 Ekip Com R Modbus RS-485 A3 Ekip Com R Modbus TCP XV XV W1R W2R W5R W6R X W1R W2R W5R W6R (A) (B) BUS 2 * L), * M), * N) (A) (B) BUS 2 * L), * M), * N) BUS 2 1SDC200638F001 A4 * L), * M), * N) 8/24 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 24 12/04/2013 14:05:54 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Module 64) Ekip COM R Profinet Redundant 65) Ekip COM R DeviceNet Redundant 66) Ekip COM R EtherNet IP Redundant 64 65 66 A4 X 8 XV K51 COM W8R n W7R RJ45 W10R Ekip Com R EtherNet IP K51 COM W11R RJ45 K51 COM Ekip Com R DeviceNet Ekip Com R Profinet A3 n XV W7R W8R X W7R W8R 1SDC200639F001 A4 (H) (L) BUS 2 * L), * M), * N) BUS 2 * L), * M), * N) BUS 2 * L), * M), * N) ABB Catalogue | 1SDC200023D0201 | 8/25 Emax2_cap08.indd 25 12/04/2013 14:05:54 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module V3 Vn Ge V2 Rct Ge- Szo Module Module TU I/O EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 Ne- Szi Ne V1 Gzo Szc Gzi Rca Trip Unit I/O TU I/O 25) Transformer star centre sensor input 27) Current sensor input on external neutral (only for 3-pole circuit-breakers) PE L1 L2 L3 25 N 27 N 8 UI/O A4 UI/N 4 1 * H) * G) Ne- Ne+ Ne- Ne+ Ne- Ne+ Ge+ Ge+ Ge+ GeGeGe- X XV A1 K51 K51 EKIP EKIP XV A4 1SDC200640F001 X As an alternative to figure 24 8/26 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 26 12/04/2013 14:05:55 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module V3 Vn Ge V2 Rct Ge- Szo Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Szi V1 Gzo Szc Gzi Trip Unit I/O 24) Rc residual current protection sensor input (ANSI 64 & 50NTD) 24a) Rc differential ground fault protection (ANSI 87N) 24 24a L1 4 Idn : 3A ... 30A Idn : 3A ... 30A 3 A4 L2 L3 4 8 3 2 2 1 1 RC RC N L1 L2 L3 PE * F) Ge- Ge+ Ge- Ge+ Rca Ge+ Rct Rct Ge- Rca Rca Rct Ge+ Ge+ Ge+ GeGe- Ge- Rct Rct Rct Rca Rca Rca X XV A1 K51 K51 EKIP EKIP XV 1SDC200641F001 X A4 As an alternative to figure 25 ABB Catalogue | 1SDC200023D0201 | 8/27 Emax2_cap08.indd 27 12/04/2013 14:05:55 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module V3 Vn Ge V2 Rct Ge- Szo Module Module TU I/O EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 Szi V1 Gzo Szc Gzi Trip Unit I/O 22) Ekip Measuring Pro for residual voltage protection (for Ekip G only) 23) Ekip Measuring/Measuring Pro with external voltage socket 22 Earthing security busbar of the switchgear or earthing mesh of the plant 8 L1 L2 23 TU1 N L1 L2 L3 L3 A4 A1 a1 B1 b1 A2 a2 B2 b2 A3 a3 B3 b3 * E) X VN V3 V2 V1 VN V3 V2 V1 XV VN V3 V2 V1 VN V3 V2 V1 L1 L2 L3 K51 MEAS Ekip Measuring Ekip Measuring Pro K51 MEAS Ekip Measuring Pro A1 XV A4 1SDC200642F001 X As an alternative to each other or to 20-21 diagram 8/28 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 28 12/04/2013 14:05:55 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module V3 Vn Ge V2 Rct Ge- Szo Module Module TU I/O EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 Szi V1 Gzo Szc Gzi Trip Unit I/O 20) Ekip Measuring/Measuring Pro with voltage socket inside the four pole circuit-breaker 21) Ekip Measuring/Measuring Pro with voltage sockets inside the three-pole circuit-breaker and connection to the external neutral 20 21 N 8 A4 X VN V3 V2 V1 VN V3 V2 V1 XV VN V3 V2 V1 VN V3 V2 V1 N L1 L2 L3 L1 L2 L3 K51 MEAS Ekip Measuring Ekip Measuring Pro K51 MEAS Ekip Measuring Ekip Measuring Pro A1 XV 1SDC200643F001 X A4 As an alternative to each other or to 22-23 diagram ABB Catalogue | 1SDC200023D0201 | 8/29 Emax2_cap08.indd 29 12/04/2013 14:05:55 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 95 35 96 36 U1 98 38 U2 S51 S33 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module V3 Vn Ge V2 Rct Ge- Szo Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 Szi V1 Gzo Szc Gzi Trip Unit I/O 26) Zone selectivity 26 A4 Gzi Gzo Gzi Gzo A1 Gzi SZo (DFo) SZi (DFi) K51 Gzo Szo Szo Szo Szi Szi Szi 8 X XV GZo (DBo) GZi (DBi) Szc EKIP XV Szc X Szc A4 Example for application diagram (among 3 circuit-breakers) K51 Szc Q1 Szo Szi Gzo Gzi K51 Szc Q2 Szo Szi Gzo Gzi Szc Q3 Szo Szi Gzo Gzi 1SDC200644F001 K51 8/30 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 30 12/04/2013 14:05:55 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 95 35 96 36 U1 98 38 U2 S51 S33 EKIP Signalling 4K V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 R1 95 35 96 36 U1 98 38 U2 S51 S33 11) 12) 13) 14) M R1 M R2 YR Trip signalling contact - S51 Contact for signalling position of loaded springs - S33 Motor for loading closing springs - M Trip contact reset coil – YR 11 12 13 + ~ 14 + ~ A4 SR 8 36 38 U1 R1 36 38 U1 R1 U1 38 98 XB1 XB7 2 3 XB2 A1 2 3 4 1 S33M/1 2 F1 S33M/2 S51 R1 98 98 36 96 96 96 X XV 1 XB2 2 35 U2 XB1 95 YR M 1 XV 95 35 U2 R2 X 95 35 U2 R2 A4 ~ ~ 1SDC200645F001 1 R2 XB7 * D) ABB Catalogue | 1SDC200023D0201 | 8/31 Emax2_cap08.indd 31 12/04/2013 14:05:56 Electrical diagrams Electrical accessories 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 51 61 52 62 54 64 HC HC HC 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 71 72 74 Q5..Q10 2) 71 H1 K3 K7 81 82 84 H2 K4 K8 91 92 94 H3 K5 K9 95 35 96 36 U1 98 38 U2 S51 S33 01 02 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 TU I/O EKIP Supply D1 YO YC2 Q1 H4 K6 04 K10 EKIP Signalling 4K Ekip Signalling 4K 2 A4 8 H1 H2 H3 H4 HC H1 H2 H3 H4 HC I 02 H4 I 03 I 04 XV K7 K8 K9 K10 HC HC X K7 K8 K9 K10 HC HC A4 1SDC200646F001 HC K10 I 01 Ekip Signalling 4K O 04 K9 O 03 HC K6 K5 K4 O 02 K8 K51 O 01 SIGN K7 A1 HC K6 K6 H3 K5 K5 H2 K4 K4 H1 K3 K3 K3 X XV Only for circuit-breakers E2.2, E4.2, E6.2 (as an alternative to figure 1) 8/32 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 32 12/04/2013 14:05:56 51 61 52 62 54 64 HC C HC C HC C Q5..Q10 51 61 52 62 54 64 HC HC HC Q5..Q10 71 72 74 H1 K3 3 K7 7 81 82 84 H2 K4 4 K8 8 91 92 94 H3 3 K5 5 K9 9 01 02 H4 4 K6 6 04 K10 0 EKIP Signalling 4K 71 72 74 H1 K3 K7 81 82 84 H2 K4 K8 91 92 94 H3 K5 K9 95 35 96 36 U1 98 38 U2 S51 S33 01 02 M R1 V3 Vn Ge Ne- 45 R2 V2 Rct Ge- Szo W3 K1 Ne 46 V1 Gzo Szc Gzi W4 K2 Rca 48 YR Szi Trip Unit I/O Module Module Module TU I/O EKIP Supply D1 C1 C11 C21 11 21 31 41 12 22 32 42 C2 C12 C22 14 24 34 44 Q2 Q3 Q4 C3 C13 D2 YU YC RTC YO2 YO YC2 Q1 H4 K6 04 K10 EKIP Signalling 4K 1) Supplementary open/closed auxiliary contacts of the circuit-breaker (second set) 1 A4 8 82 84 92 94 02 04 82 84 92 94 02 04 94 84 Q/10 01 Q/9 91 Q/8 81 61 Q/7 71 Q/6 74 64 54 Q/5 51 A1 04 74 74 02 72 72 92 64 64 82 62 62 72 54 54 62 52 52 52 X XV XV 51 61 71 81 91 01 X 51 61 71 81 91 01 1SDC200647F001 A4 Only for circuit-breakers E2.2, E4.2, E6.2 (as an alternative to figure 2) ABB Catalogue | 1SDC200023D0201 | 8/33 Emax2_cap08.indd 33 12/04/2013 14:05:56 Electrical diagrams Electrical accessories 91) Supplementary open/closed auxiliary contacts outside the circuit-breaker 91 202 204 Q/11 282 214 Q/12 201 A4 8 212 284 Q/19 292 224 Q/13 211 294 Q/20 302 234 Q/14 221 304 Q/21 291 232 312 244 Q/15 231 314 Q/22 301 242 322 254 Q/16 241 324 Q/23 311 252 332 264 Q/17 251 334 Q/24 321 262 274 Q/18 261 342 272 271 344 Q/25 331 341 1SDC200648F001 281 222 8/34 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 34 12/04/2013 14:05:56 95) Contacts for signalling circuit-breakers in racked-in, test, racked-out position 95 A4 2 4 S75E/1 142 154 4 S75E/2 1 1 2 A3 4 S75T/1 2 4 S75T/2 1 1 4 2 S75I/1 4 2 111 121 131 141 151 1SDC200649F001 A4 1 151 141 131 121 111 101 101 8 S75I/2 1 XF 152 152 144 154 134 142 132 144 124 134 114 2 122 132 114 124 112 122 104 104 102 102 112 XF Only for circuit-breakers E1.2 in withdrawable version ABB Catalogue | 1SDC200023D0201 | 8/35 Emax2_cap08.indd 35 12/04/2013 14:05:56 Electrical diagrams Electrical accessories 96) Contacts for signalling circuit-breakers in racked-in, test, racked-out position (first set) 96 A4 2 S75I/1 4 124 134 142 2 S75I/2 1 1 2 4 S75T/1 1 2 4 S75E/1 2 4 S75E/2 111 131 121 111 101 A4 101 121 1 141 1 8 131 141 1SDC200650F001 A3 XF 144 144 132 142 124 134 122 132 114 122 102 4 112 114 104 104 102 112 XF Only for circuit-breakers E2.2, E4.2, E6.2 in withdrawable version 8/36 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 36 12/04/2013 14:05:57 97) Supplementary contacts for signalling circuit-breakers in racked-in, test, racked-out position (second set) 97 A4 2 S75I/3 4 174 184 192 2 S75I/4 1 1 2 4 S75T/2 A3 1 2 4 S75E/3 2 4 S75E/4 151 171 8 191 181 171 161 1 181 191 1SDC200651F001 A4 161 151 1 XF 194 194 182 192 174 184 172 182 164 172 152 4 162 164 154 154 152 162 XF Only for circuit-breakers E2.2, E4.2, E6.2 in withdrawable version ABB Catalogue | 1SDC200023D0201 | 8/37 Emax2_cap08.indd 37 12/04/2013 14:05:57 Electrical diagrams ATS021 and ATS022 98) Circuit-breakers without auxiliary safety voltage 98 NORMAL SUPPLY N Q61/1 L1 L2 EMERGENCY SUPPLY L3 N L1 L2 L3 Q61/2 6 5 5 6 4 3 3 4 2 1 1 2 8 7 7 8 CB1-N CB2-E M M # # X61 A 4 3 1 2 2 3 4 1 2 ONLY FOR ATS021 21 K1 22 1 22 2 X21 21 DO1 DO3 3 A1 K1 K2 A2 A2 X C11 X C1 X U1 X C11 X C1 X U1 XV C11 XV C1 XV U1 XV C11 XV C1 XV U1 43 K2 44 44 YO YC S33M 1 M XV C12 XV C2 XV U2 X C12 X C2 X U2 CB2-E 43 CB1-N S33M 1 K1 DO2 A1 YO YC 1 2 3 DO4 ATS021 - ATS022 M XV C12 XV C2 XV U2 X C12 X C2 X U2 1SDC200652ENF001 K2 X22 8 X12 14 K2 14 1 X14 2 X13 K1 13 X11 1 13 8/38 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 38 12/04/2013 14:05:57 99) Circuit-breakers with auxiliary safety voltage in direct current 99 3 2 1 1L1 4 1L1 KO1 1L1 KC1 KO2 1L1 2 3 KC2 2T1 2T1 2T1 2T1 3L2 3L2 3L2 3L2 KO1 KC1 KO2 4T2 4T2 4T2 2 5L3 5L3 5L3 5L3 3 KC1 6T3 KO2 KC2 6T3 6T3 6T3 C11 X C1 X U1 X C11 X C1 X U1 XV C11 XV C1 XV U1 XV C11 XV C1 XV U1 YC DO4 S33M 1 M XV C12 XV C2 XV U2 X C12 X C2 X U2 CB2-E CB1-N YO DO3 DO2 ATS021 - ATS022 A X S33M 1 DO1 1 KC2 4T2 KO1 X21 - Q60 X22 1 POSIZIONE CODICE ACODICE0 ACODICE1 ACODICE2 UBICAZIONE NOTE1 NOTE2 + NOTE2 NOTE1 UBICAZIONE ACODICE2 ACODICE1 ACODICE0 CODICE POSIZIONE -+ YO YC M XV C12 XV C2 XV U2 X C12 X C2 X U2 A1 A1 A1 A1 KO1 KC1 KO2 KC2 A2 A2 A2 A2 8 99) Circuit-breakers with auxiliary safety voltage in alternating current N 3 Q60 2 1 4 2 X21 1 NOTE2 NOTE1 UBICAZIONE ACODICE2 ACODICE1 ACODICE0 CODICE POSIZIONE L POSIZIONE CODICE ACODICE0 ACODICE1 ACODICE2 UBICAZIONE NOTE1 NOTE2 ~ DO1 X22 99 DO3 3 1 2 3 X C11 X C1 X U1 X C11 X C1 X U1 XV C11 XV C1 XV U1 XV C11 XV C1 XV U1 YO YC DO4 ATS021 - ATS022 S33M 1 M XV C12 XV C2 XV U2 X C12 X C2 X U2 CB2-E CB1-N S33M 1 A DO2 YO YC M XV C12 XV C2 XV U2 X C12 X C2 X U2 ABB Catalogue | 1SDC200023D0201 | 8/39 Emax2_cap08.indd 39 12/04/2013 14:05:57 Electrical diagrams ATS021 and ATS022 100) ATS021 100 1 X12 3 3 X22 CB2-E 1 2 3 CB2-E X XV CB1-N XF S51 95 S75I/1 142 * XV X CB2-E XF 96 96 # XF 141 X XV 96 S51 96 * XV DO4 DO8 STOP GENERATOR COMMAND 1 ATS021 NORMAL OPERATING SIGNALLING 2 3 DO7 ALIM. L2 X14 X23 1 START GENERATOR COMMAND 2 ATS021 ALARM SIGNALLING 1 2 MANUAL MODE SIGNALLING 3 LOGIC ENABLE/DISABLE SIGNALLING X 95 95 1 Q/1 XV Q/1 XV 2 14 14 11 11 X XV X X31 X XV X 3 14 14 11 11 8 DO6 DO3 XF S11 CB2-E 1 2 3 142 LOGIC ENABLE/DISABLE CB1-N DO2 # S75I/1 141 CB1-N DO5 DO1 X24 X21 CB1-N 2 X25 1 2 1 95 3 4 X13 ALIM. L1 4 2 MEASURE L2 X61 1 2 X11 MEASURE L1 A 4 ATS021 101) ATS022 101 X12 X21 X22 CB2-E 3 CB2-E CB1-N # * * XF XF 141 142 X XV XV 95 X XV 95 S51 95 95 96 96 S51 XV DI9 4 DI8 6 X X 96 96 DI10 3 5 142 S75I/1 DO10 2 NOT USED 3 NOT USED 4 CIRCUIT-BREAKER ALARM SIGNALLING 5 MANUAL MODE SIGNALLING 6 LOGIC ENABLE/DISABLE SIGNALLING 7 1 2 BUS 1 3 DI7 7 DI5 8 DI4 9 COM S11 1 DI6 2 X31 CB1-N XF 1 ATS022 ALARM SIGNALLING X51 PROGRAMMABLE INPUT S75I/1 DO7 2 X32 S15 XF DO4 (SEE FIG. 102) DO8 2 COMMAND TO FORCE TO TRANSFER 141 DO6 1 CB3 CIRCUIT-BREAKER POSITION DO12 S13 # DO3 1 S14 CB2-E DO11 DO9 S12 START GENERATOR COMMAND (NA/NC PROGRAMMABLE) DO2 3 1 CB3 CIRCUIT-BREAKER POSITION (SEE FIG. 102) DO1 STOP GENERATOR COMMAND 3 ATS022 4 LOGIC ENABLE/DISABLE X XV Q/1 X XV X 11 11 14 14 14 14 XV Q/1 XV 11 11 X CB1-N CB2-E 1SDC200653ENF001 CB1-N 3 2 1 START GENERATOR COMMAND 2 3 1 2 DO5 X23 1 2 X24 24...110Vdc - X29 + 3 4 X41 4 (A) (B) 3 1 2 MEASURE L2 X61 1 2 X11 MEASURE L1 A 8/40 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 40 12/04/2013 14:05:58 102) Third circuit-breaker control with ATS022 102 A ~ CB3 CIRCUIT-BREAKER POSITION Q/1 CB3 XV X 1 11 11 DO11 1 X24 X XV 14 14 16 KO3 2 Impulse-OFF 15 3 2 16 3 X 31 X 21 XV 31 XV 21 Q/3 XV X32 X XV 34 X Impulse-OFF 15 CB3 34 18 KC3 Q/2 CB3 4 5 18 X C11 X C1 X U1 XV C11 XV C1 XV U1 22 22 S33M 1 6 7 8 ATS 022 A1 Y1 KO3 KC3 A2 A2 YC M C12 XV C2 XV U2 X C12 X C2 X U2 ~ 1SDC200654ENF001 9 A1 Y1 CB3 YO XV 8 Possible configurations - ATS022 with three circuit-breakers NORMAL SUPPLY EMERGENCY SUPPLY CB1-N CB2-E M M NORMAL SUPPLY EMERGENCY SUPPLY CB1-N CB2-E M M CB3 NORMAL SUPPLY 1 NORMAL SUPPLY 2 CB1-N CB2-N M M CB3 CB3 M NON PRIORITY LOADS M NON PRIORITY LOADS M NON PRIORITY LOADS Note: Use auxiliary voltage of 110-130V AC or 220-240V AC. ABB Catalogue | 1SDC200023D0201 | 8/41 Emax2_cap08.indd 41 12/04/2013 14:05:58 Electrical diagrams Power Controller 103) Ekip Signalling 10K 103 * A) + * Q) TO W3-W4 24/48 VDC EKIP LINK + 110-240 VAC/DC K101 A13 O101 O102 O103 K104 K105 O104 K106 K107 O105 K108 K109 O106 K110 K111 O107 K112 K113 O108 K114 K115 O109 K116 K117 K119 O110 H101 I101 K118 K120 H103 I102 H102 H104 H105 H107 I103 I104 H106 H109 I105 H108 H111 I106 H110 H112 H113 I107 H115 I108 H114 H117 I109 H116 H119 I110 H118 H120 H121 VDC+ VDC- L+ L- W3 W4 W13 I111 H122 EKIP SIGNALLING 10K 1SDC200655F001 K102 K103 RJ45 * C) - 8 104) Ekip Multimeter 104 K51 EKIP * A) XV X K1 K2 K1 K2 XV X W3 W4 W3 W4 * Q) + 24/48 VDC + 110-240 VAC/DC - VDC+ VDC- L+ L- ODC+ ODC- W3 W4 A15 1SDC200656F001 EKIP MULTIMETER 8/42 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 42 12/04/2013 14:05:58 105) Application diagram for Ekip Touch, Hi-Touch, G Touch, G Hi-Touch with Power Controller function 105 Q2 - EMAX 2 Q1 - EMAX 2 WITH EKIP POWER CONTROLLER + ~ Q3 - TMAX XT + MOE + ~ + ~ JG2-XE3 XV 96 98 X 12 14 XV 12 14 X XV 11 X 95 K51 SIGN U1 XV 05 JG2-XE3 K11 K13 H11 H12 HC1 XV K11 K13 H11 H12 HC1 O 11 O 12 I 11 I 12 XV U1 X K1 K2 XV K1 K2 K51 SUPPLY XV K12 X F1 X C11 X C1 XV C11 XV C1 YO YC K12 X K3 K4 K5 K6 H1 H2 H3 H4 HC XV K3 K4 K5 K6 H1 H2 H3 H4 HC K51 O 01 SIGN O 02 O 03 X K14 X W3 O 04 I 01 I 02 I 03 I 04 XD1 12 14 XV 12 14 JB1-XD2 JA1-XD2 Q/1 C11 JA1-XD2 A1 XV A1 XV C11 X K7 K8 K9 K10 K8 K9 K10 XV HC X HC XD1 11 HC HC A17 W4 MOE K14 M M YC XV U2 (A) (B) XV U2 X XV C12 X U2 X JA1-XD2 (LOCAL BUS) XV C2 C12 U1 XV U1 XV 11 XV K7 XV W4 XV W3 S33M/1 05 11 X X 08 08 ENERGY CLOCK METER XV 95 06 XV 06 S51 Q/1 S51 Ekip Signalling 4K 98 Ekip Supply 110-240VAC/DC Ekip Supply 24-48VDC 96 Ekip Signalling 2K-1 X C2 U2 R1 ~ ~ 1SDC200657ENF001 ~ Q2 - EMAX 2 Q1 - EMAX 2 WITH EKIP POWER CONTROLLER + ~ 105 Q3 - TMAX XT + MOE + ~ + ~ JG2-XE3 XV X XV 96 98 96 98 8 06 08 06 08 S51 S51 XV 95 X K1 K2 X 95 XV K1 K2 K51 SUPPLY X U1 XV U1 S33M/1 C11 X C1 XV C11 XV C1 M YO XV W3 XV W4 X W3 X W4 XV U2 XV C12 XV C2 X U2 X C12 X C2 12 14 XD1 12 14 XV 12 14 JA1-XD2 XV C11 U1 XV U1 12 14 MOE M Q/1 YC XV JA1-XD2 XV 11 XV 11 X 11 XD1 11 U2 U2 R1 ~ ~ A1 A17 X Q/1 C11 A1 XV XV YC 05 JB1-XD2 JA1-XD2 (LOCAL BUS) F1 X 05 JG2-XE3 Ekip Supply 110-240VAC/DC Ekip Supply 24-48VDC XV ~ + ~ A13 O101 K103 O102 K102 H101 I101 K104 H102 H121 W13 W3 W4 VDC+ VDC- L+ L- I111 H122 H103 I102 EKIP SIGNALLING 10K H104 K105 O103 K107 O104 K106 K108 1SDC200658ENF001 K101 RJ45 ENERGY CLOCK METER ~ ABB Catalogue | 1SDC200023D0201 | 8/43 Emax2_cap08.indd 43 12/04/2013 14:05:59 Electrical diagrams Power Controller 105 Q4 - EMAX 2 MS Q2 - EMAX 2 + ~ Q1 - EMAX 2 WITH EKIP POWER CONTROLLER + ~ + ~ + ~ ENERGY CLOCK METER + ~ Q3 - TMAX XT + MOE JG2-XE3 XV 06 08 06 08 S51 K2 XV K1 K2 Ekip Supply 110-240VAC/DC Ekip Supply 24-48VDC K51 SIGN K51 SUPPLY X X XV C13 XV C3 S33M/1 F1 M X C11 X C1 XV C11 XV C1 YO X 12 14 XV 12 14 YC XV U2 XV C12 XV C2 X U2 X C12 X C2 K51 YO F1 M Q/1 XV 11 X 11 K51 YC YO YC XV U2 XV C12 XV C2 X U2 X C12 X C2 S75I/5 K51 COM W13 XV W3 XV W4 X W3 X W4 H11 H12 HC1 H11 H12 HC1 O 11 O 12 XV K13 X K13 I 11 K14 K2 XV K1 K2 S75I/5 K51 COM (A) (B) (LOCAL BUS) JG2-XE3 XV W3 XV W4 X W3 X W4 05 JB1-XD2 JA1-XD2 C11 JA1-XD2 A1 XV A1 XV C11 U1 XV U1 A17 XD1 12 14 XV 12 14 MOE M Q/1 (A) (B) W13 05 YC XV JA1-XD2 (LOCAL BUS) XV 11 XD1 11 U2 U2 R1 n ~ ~ RJ45 BUS 1 ~ RJ45 BUS 1 ~ XV K1 K51 SUPPLY K14 n ~ I 12 X Ekip Link U1 Ekip Com Actuator S33M/1 X XV C3 K12 K12 RJ45 U1 C13 Ekip Link XV U1 RJ45 X U1 K11 XV K11 Ekip Signalling 2K-1 K1 Ekip Supply 110-240VAC/DC Ekip Supply 24-48VDC X X A21 RJ45 ETHERNET SWITCH + ~ 8 O101 K103 O102 K102 H101 W13 W3 W4 VDC+ VDC- L+ L- I101 K104 H102 H103 I102 EKIP SIGNALLING 10K H104 K105 O103 K107 O104 K106 K108 1SDC200659ENF001 K101 A13 RJ45 ~ 8/44 | 1SDC200023D0201 | ABB Catalogue Emax2_cap08.indd 44 12/04/2013 14:05:59 Ordering codes Instructions for ordering Ordering examples 9/2 General information 9/5 Automatic circuit-breakers Fixed version for power distribution 9/6 Withdrawable version for power distribution 9/21 Fixed version for generators 9/35 Withdrawable version for generators 9/40 Switch-disconnectors Fixed version 9/45 Withdrawable version 9/48 Version for applications up to 1150V AC 9/50 Fixed version for applications up to 1000V DC 9/51 Withdrawable version for applications up to 1000V DC 9/52 Derived versions Sectionalizing truck 9/53 Earthing truck 9/53 Earthing switch with making capacity 9/53 Fixed parts 9/54 9 Accessories Electrical accessories 9/55 Mechanical accessories 9/58 Mechanical interlock 9/61 Ekip modules 9/62 Terminals 9/65 ABB Catalogue | 1SDC200023D0201 | 9/1 Emax2_cap09.indd 1 15/04/2013 18:00:42 Instructions for ordering Ordering examples Standard version Emax 2 series circuit-breakers are identified by means of commercial codes that can be accessorized. Ordering examples – Terminal kit codes (other than standard supply) for fixed circuit-breaker or for fixed part of withdrawable circuit-breaker. The codes refer to 3 or 4 pieces (for mounting on top or bottom terminals). To convert a complete circuit-breaker, 1 kit for upper terminals and 1 kit for lower terminals must be specified in the order. Example no. 1 Emax E2.2N 3 poles fixed with vertical rear terminals (VR) 1SDA071066R1 E2.2N 2500 Ekip Touch LSIG 3p F HR 1SDA074009R1 Kit VR Sup E2.2 Iu=2500 3pcs INST 1SDA074011R1 Kit VR Inf E2.2 Iu=2500 3pcs INST Example no. 2 Emax E1.2N 4 poles fixed with upper vertical rear (VR) and front (F) terminals (standard supply) 1SDA071513R1 E1.2N 1600 Ekip Dip LSIG 4p F F 1SDA073986R1 Kit VR Upper E1.2 F 4pcs INST Example no. 3 Emax E4.2H 3 poles fixed with upper front terminals (F) and adjustable rear bottom vertical (VR) terminals 1SDA071169R1 E4.2H 3200 Ekip Hi-Touch LSIG 3p F HR 1SDA074126R1 Kit F upper E4.2 F 3pcs INST 1SDA074017R1 Kit VR lower E4.2 Iu=3200 3pcs INST Example no. 4 9 Emax E2.2 2000A 3 poles fixed part with spread upper vertical terminals (SVR) and rear bottom adjustable horizontal (HR) terminals (standard supply) 1SDA073909R1 E2.2 W FP Iu=2000 3p HR HR 1SDA074057R1 Kit SVR upper E2.2 Iu=2000 3pcs INST – Rating Plug for lower values than rated current. Rating plug installed on the circuit-breaker enables to obtain lower current values than rated current. Example no. 5 Emax E2.2S 2500 4 poles fixed In=1600A 1SDA071706R1 E2.2S 2500 Ekip Touch LSIG 4p F HR 1SDA074266R1 Rating Plug 1600 E1.2..E6.2 INST – Special version for rated service voltages up to 1150V AC. Upgrade kits for SACE Emax 2 circuit-breakers enables the version for applications up to 1150V AC. Example no. 6 Emax E6.2X 6300 4 poles fixed for applications up to 1150V AC 1SDA071949R1 E6.2X 6300 Ekip HI-Touch LSIG 4p F HR 1SDA074347R1 E6.2X/E Iu=6300 Upgrade Kit 1150V AC 4p 9/2 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 2 15/04/2013 18:00:42 – Ordering for Ekip modules. Ekip Supply module enables Ekip Com, Ekip Link, Ekip 2K, Ekip Syncrocheck cartridge modules to be installed. In addition to Ekip Supply modules, up to 3 cartridge modules can be installed on E2.2, E4.2 and E6.2 and up to 2 modules on E1.2. Ekip Fan module can be installed as an alternative of Ekip Supply only on withdrawable version of E2.2, E4.2 and E6.2. In addition to Ekip Fan, up to 2 modules can be installed. Example no. 7 Emax E4.2H 3 poles fixed with modules: Ekip Supply, Ekip Com Modbus TCP, Ekip Signalling 2K-1, Ekip Com Modbus TCP Redundant and Ekip Signalling 4K 1SDA071169R1 E4.2H 3200 Ekip Hi-Touch LSIG 3p F HR 1SDA074173R1 Ekip Supply 24-48V DC E1.2..E6.2 1SDA074151R1 Ekip Com Modbus TCP E1.2..E6.2 1SDA074158R1 Ekip Com R Modbus TCP E1.2..E6.2 1SDA074167R1 Ekip Sign. 2K-1 E1.2..E6.2 1SDA074170R1 Ekip Sign. 4K E2.2..E6.2 Example no. 8 Emax E4.2H 3 poles fixed with modules: Ekip Fan, Ekip Com EtherNet/IP, Ekip Com Modbus RS-485 and Ekip Measuring Pro 1SDA071166R1 E4.2H 3200 Ekip Touch LSIG 3p F HR 1SDA074174R1 Ekip Fan 24VDC E2.2..E6.2 1SDA074155R1 Ekip Com EtherNet/IP E1.2..E6.2 1SDA074150R1 Ekip Com Modbus RS-485 E1.2..E6.2 1SDA074189R1 Ekip Measuring Pro E4.2 9 Example no. 9 Emax E1.2N 4 poles fixed with modules: Ekip Supply, Ekip Link 1SDA071513R1 E1.2N 1600 Ekip Dip LSIG 4p F F 1SDA074172R1 Ekip Supply 110-240V AC/DC E1.2..E6.2 1SDA074163R1 Ekip Link E1.2..E6.2 – Ordering for electrical accessories. All the accessories are available. In particular, up to 3 coils can be ordered for E1.2, whereas up to 4 coils for E2.2, E4.2 and E6.2. Example no. 10 Emax E2.2S 3 poles withdrawable with accessories: opening release, closing release, motor for automatic charging of the springs, second opening release 1SDA072395R1 E2.2S 2000 Ekip Touch LSi LSIG 3p WMP 1SDA073674R1 YO E1.2..E6.2 220-240V AC/DC 1SDA073687R1 YC E1.2..E6.2 220-240V AC/DC 1SDA073725R1 M E2.2...E6.2 220-250V AC/DC 1SDA073674R1 YO E1.2..E6.2 220-240V AC/DC – Ordering for key locks. Example no. 11 Emax E2.2N 3 poles with double key lock in racked-in / test / racked-out position, using different keys 1SDA071066R1 E2.2N 2500 Ekip Touch LSIG 3p F HR 1SDA073806R1 KLP-D Bl. Racked in/out E2.2...E6.2 1st key 1SDA073812R1 KLP-D Bl. Racked in/out E2.2...E6.2 2nd key ABB Catalogue | 1SDC200023D0201 | 9/3 Emax2_cap09.indd 3 15/04/2013 18:00:42 Instructions for ordering Ordering examples – Ordering for mechanical Interlocks. Interlocks have several strategy configuration, suitable for fixed circuit-breakers and withdrawable circuit-breakers. Each configuration requires different groups: - Cables, select one Kit for strategy A / B / C / D. The cables must be ordered on fixed circuit-breaker or fixed part of withdrawable circuit-breaker. - Lever, required only for E2.2, E4.2 and E6.2. These lever must be mounted on fixed circuit-breaker or on mobile part of withdrawable circuit-breaker. - Support, installed on fixed circuit-breaker or on fixed part of withdrawable circuit-breaker. This support is mounted on the external right side of the circuit-breaker. Example no. 12 Interlock between two fixed circuit-breakers: E1.2 and E2.2 E1.2 Fixed circuit-breaker E2.2 Fixed circuit-breaker Cables [Group 1]: 1 Item Lever [Group 2]: 1 Item Support [Group 3]: 1 Item Support [Group 3]: 1 Item Example no. 13 Interlock between three fixed circuit-breakers: one E2.2 and two E4.2 E2.2 Fixed circuit-breaker E4.2 Fixed circuit-breaker E4.2 Fixed circuit-breaker Cables [Group 1]: 1 Item Lever [Group 2]: 1 Item Lever [Group 2]: 1 Item Lever [Group 2]: 1 Item Support [Group 3]: 1 Item Support [Group 3]: 1 Item Support [Group 3]: 1 Item Example no. 14 Interlock between two withdrawable circuit-breakers: E1.2 and E2.2 9 E1.2 Fixed Part E2.2 Mobile Part Cables [Group 1]: 1 Item Lever [Group 2]: 1 Item Support [Group 4]: 1 Item + E2.2 Fixed Part Support [Group 4]: 1 Item Example no. 15 Interlock between three withdrawable circuit-breakers: one E2.2 and two E4.2 E2.2 Mobile Part E4.2 Mobile Part E4.2 Mobile Part Lever [Group 2]: 1 Item Lever [Group 2]: 1 Item Lever [Group 2]: 1 Item E2.2 Fixed Part E4.2 Fixed Part E4.2 Fixed Part Cables [Group 1]: 1 Item Support [Group 4]: 1 Item Support [Group 4]: 1 Item + Support [Group 4]: 1 Item 9/4 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 4 15/04/2013 18:00:42 General informations Abbreviations used for the description of the product Versions and terminals F Fixed circuit-breaker W Withdrawable circuit-breaker MP Mobile part of withdrawable circuit-breaker FP Fixed part of withdrawable circuit-breaker Iu Rated uninterrupted current In Rated current of the rating plug Icu Rated ultimate short-circuit breaking capacity Icw Rated short-time withstand current /MS Switch-disconnector /E Circuit-breakers for 1150V applications /f Four-pole circuit-breakers with neutral pole at 100% CS Sectionalizing truck MT Earthing truck MTP Earthing switch with making capacity HR VR Rear orientable terminals SHR Horizontal rear spread terminals VHR Vertical rear spread terminals F Front terminals FL Flat terminals EF Extended front terminals ES Front spread terminals Fc CuAl Terminals for cables 9 Protection trip units and functions Ekip Dip Protection trip unit for power distribution Ekip Touch Measurement and protection trip unit for power distribution Ekip Hi Touch Measurement and protection trip unit and network analyzer for power distribution Ekip G Touch Measurement and protection trip unit for generators Ekip G Hi-Touch Measurement and protection trip unit and protection network analyzer for generators L Overload protection S Protection against selective short circuit I Protection against instantaneous short circuit G Earth fault protection Rc Residual current protection Power Controller Load management function ABB Catalogue | 1SDC200023D0201 | 9/5 Emax2_cap09.indd 5 15/04/2013 18:00:42 Automatic circuit-breakers Fixed version for power distribution 1SDC200661F001 SACE Emax E1.2B • Front terminals (F) Size E1.2B Iu 630 800 1000 Icu Icw (440 V) (1s) Type 42 42 42 42 42 42 9 1250 1600 42 42 42 42 3 Poles 4 Poles Code Code E1.2B 630 Ekip Dip LI 1SDA070701R1 1SDA071331R1 E1.2B 630 Ekip Dip LSI 1SDA070702R1 1SDA071332R1 E1.2B 630 Ekip Dip LSIG 1SDA070703R1 1SDA071333R1 E1.2B 630 Ekip Touch LI 1SDA070704R1 1SDA071334R1 E1.2B 630 Ekip Touch LSI 1SDA070705R1 1SDA071335R1 E1.2B 630 Ekip Touch LSIG 1SDA070706R1 1SDA071336R1 E1.2B 630 Ekip Hi-Touch LSI 1SDA070708R1 1SDA071338R1 E1.2B 630 Ekip Hi-Touch LSIG 1SDA070709R1 1SDA071339R1 E1.2B 800 Ekip Dip LI 1SDA070741R1 1SDA071371R1 E1.2B 800 Ekip Dip LSI 1SDA070742R1 1SDA071372R1 E1.2B 800 Ekip Dip LSIG 1SDA070743R1 1SDA071373R1 E1.2B 800 Ekip Touch LI 1SDA070744R1 1SDA071374R1 E1.2B 800 Ekip Touch LSI 1SDA070745R1 1SDA071375R1 E1.2B 800 Ekip Touch LSIG 1SDA070746R1 1SDA071376R1 E1.2B 800 Ekip Hi-Touch LSI 1SDA070748R1 1SDA071378R1 E1.2B 800 Ekip Hi-Touch LSIG 1SDA070749R1 1SDA071379R1 E1.2B 1000 Ekip Dip LI 1SDA070781R1 1SDA071411R1 E1.2B 1000 Ekip Dip LSI 1SDA070782R1 1SDA071412R1 E1.2B 1000 Ekip Dip LSIG 1SDA070783R1 1SDA071413R1 E1.2B 1000 Ekip Touch LI 1SDA070784R1 1SDA071414R1 E1.2B 1000 Ekip Touch LSI 1SDA070785R1 1SDA071415R1 E1.2B 1000 Ekip Touch LSIG 1SDA070786R1 1SDA071416R1 E1.2B 1000 Ekip Hi-Touch LSI 1SDA070788R1 1SDA071418R1 E1.2B 1000 Ekip Hi-Touch LSIG 1SDA070789R1 1SDA071419R1 E1.2B 1250 Ekip Dip LI 1SDA070821R1 1SDA071451R1 E1.2B 1250 Ekip Dip LSI 1SDA070822R1 1SDA071452R1 E1.2B 1250 Ekip Dip LSIG 1SDA070823R1 1SDA071453R1 E1.2B 1250 Ekip Touch LI 1SDA070824R1 1SDA071454R1 E1.2B 1250 Ekip Touch LSI 1SDA070825R1 1SDA071455R1 E1.2B 1250 Ekip Touch LSIG 1SDA070826R1 1SDA071456R1 E1.2B 1250 Ekip Hi-Touch LSI 1SDA070828R1 1SDA071458R1 E1.2B 1250 Ekip Hi-Touch LSIG 1SDA070829R1 1SDA071459R1 E1.2B 1600 Ekip Dip LI 1SDA070861R1 1SDA071491R1 E1.2B 1600 Ekip Dip LSI 1SDA070862R1 1SDA071492R1 E1.2B 1600 Ekip Dip LSIG 1SDA070863R1 1SDA071493R1 E1.2B 1600 Ekip Touch LI 1SDA070864R1 1SDA071494R1 E1.2B 1600 Ekip Touch LSI 1SDA070865R1 1SDA071495R1 E1.2B 1600 Ekip Touch LSIG 1SDA070866R1 1SDA071496R1 E1.2B 1600 Ekip Hi-Touch LSI 1SDA070868R1 1SDA071498R1 E1.2B 1600 Ekip Hi-Touch LSIG 1SDA070869R1 1SDA071499R1 9/6 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 6 15/04/2013 18:00:42 1SDC200661F001 SACE Emax E1.2C • Front terminals (F) Size E1.2C Iu 630 800 1000 1250 1600 Icu Icw (440 V) (1s) Type 50 50 50 50 50 42 42 42 42 42 3 Poles 4 Poles Code Code E1.2C 630 Ekip Dip LI 1SDA070711R1 1SDA071341R1 E1.2C 630 Ekip Dip LSI 1SDA070712R1 1SDA071342R1 E1.2C 630 Ekip Dip LSIG 1SDA070713R1 1SDA071343R1 E1.2C 630 Ekip Touch LI 1SDA070714R1 1SDA071344R1 E1.2C 630 Ekip Touch LSI 1SDA070715R1 1SDA071345R1 E1.2C 630 Ekip Touch LSIG 1SDA070716R1 1SDA071346R1 E1.2C 630 Ekip Hi-Touch LSI 1SDA070718R1 1SDA071348R1 E1.2C 630 Ekip Hi-Touch LSIG 1SDA070719R1 1SDA071349R1 E1.2C 800 Ekip Dip LI 1SDA070751R1 1SDA071381R1 E1.2C 800 Ekip Dip LSI 1SDA070752R1 1SDA071382R1 E1.2C 800 Ekip Dip LSIG 1SDA070753R1 1SDA071383R1 E1.2C 800 Ekip Touch LI 1SDA070754R1 1SDA071384R1 E1.2C 800 Ekip Touch LSI 1SDA070755R1 1SDA071385R1 E1.2C 800 Ekip Touch LSIG 1SDA070756R1 1SDA071386R1 E1.2C 800 Ekip Hi-Touch LSI 1SDA070758R1 1SDA071388R1 E1.2C 800 Ekip Hi-Touch LSIG 1SDA070759R1 1SDA071389R1 E1.2C 1000 Ekip Dip LI 1SDA070791R1 1SDA071421R1 E1.2C 1000 Ekip Dip LSI 1SDA070792R1 1SDA071422R1 E1.2C 1000 Ekip Dip LSIG 1SDA070793R1 1SDA071423R1 E1.2C 1000 Ekip Touch LI 1SDA070794R1 1SDA071424R1 E1.2C 1000 Ekip Touch LSI 1SDA070795R1 1SDA071425R1 E1.2C 1000 Ekip Touch LSIG 1SDA070796R1 1SDA071426R1 E1.2C 1000 Ekip Hi-Touch LSI 1SDA070798R1 1SDA071428R1 E1.2C 1000 Ekip Hi-Touch LSIG 1SDA070799R1 1SDA071429R1 E1.2C 1250 Ekip Dip LI 1SDA070831R1 1SDA071461R1 E1.2C 1250 Ekip Dip LSI 1SDA070832R1 1SDA071462R1 E1.2C 1250 Ekip Dip LSIG 1SDA070833R1 1SDA071463R1 E1.2C 1250 Ekip Touch LI 1SDA070834R1 1SDA071464R1 E1.2C 1250 Ekip Touch LSI 1SDA070835R1 1SDA071465R1 E1.2C 1250 Ekip Touch LSIG 1SDA070836R1 1SDA071466R1 E1.2C 1250 Ekip Hi-Touch LSI 1SDA070838R1 1SDA071468R1 E1.2C 1250 Ekip Hi-Touch LSIG 1SDA070839R1 1SDA071469R1 E1.2C 1600 Ekip Dip LI 1SDA070871R1 1SDA071501R1 E1.2C 1600 Ekip Dip LSI 1SDA070872R1 1SDA071502R1 E1.2C 1600 Ekip Dip LSIG 1SDA070873R1 1SDA071503R1 E1.2C 1600 Ekip Touch LI 1SDA070874R1 1SDA071504R1 E1.2C 1600 Ekip Touch LSI 1SDA070875R1 1SDA071505R1 E1.2C 1600 Ekip Touch LSIG 1SDA070876R1 1SDA071506R1 E1.2C 1600 Ekip Hi-Touch LSI 1SDA070878R1 1SDA071508R1 E1.2C 1600 Ekip Hi-Touch LSIG 1SDA070879R1 1SDA071509R1 9 ABB Catalogue | 1SDC200023D0201 | 9/7 Emax2_cap09.indd 7 15/04/2013 18:00:43 Automatic circuit-breakers Fixed version for power distribution 1SDC200661F001 SACE Emax E1.2N • Front terminals (F) Size E1.2N Iu 250 630 800 Icu Icw (440 V) (1s) Type 66 66 66 50 50 50 9 1000 1250 1600 66 66 66 50 50 50 3 Poles 4 Poles Code Code E1.2N 250 Ekip Dip LI 1SDA070691R1 1SDA071321R1 E1.2N 250 Ekip Dip LSI 1SDA070692R1 1SDA071322R1 E1.2N 250 Ekip Dip LSIG 1SDA070693R1 1SDA071323R1 E1.2N 250 Ekip Touch LI 1SDA070694R1 1SDA071324R1 E1.2N 250 Ekip Touch LSI 1SDA070695R1 1SDA071325R1 E1.2N 250 Ekip Touch LSIG 1SDA070696R1 1SDA071326R1 E1.2N 250 Ekip Hi-Touch LSI 1SDA070698R1 1SDA071328R1 E1.2N 250 Ekip Hi-Touch LSIG 1SDA070699R1 1SDA071329R1 E1.2N 630 Ekip Dip LI 1SDA070721R1 1SDA071351R1 E1.2N 630 Ekip Dip LSI 1SDA070722R1 1SDA071352R1 E1.2N 630 Ekip Dip LSIG 1SDA070723R1 1SDA071353R1 E1.2N 630 Ekip Touch LI 1SDA070724R1 1SDA071354R1 E1.2N 630 Ekip Touch LSI 1SDA070725R1 1SDA071355R1 E1.2N 630 Ekip Touch LSIG 1SDA070726R1 1SDA071356R1 E1.2N 630 Ekip Hi-Touch LSI 1SDA070728R1 1SDA071358R1 E1.2N 630 Ekip Hi-Touch LSIG 1SDA070729R1 1SDA071359R1 E1.2N 800 Ekip Dip LI 1SDA070761R1 1SDA071391R1 E1.2N 800 Ekip Dip LSI 1SDA070762R1 1SDA071392R1 E1.2N 800 Ekip Dip LSIG 1SDA070763R1 1SDA071393R1 E1.2N 800 Ekip Touch LI 1SDA070764R1 1SDA071394R1 E1.2N 800 Ekip Touch LSI 1SDA070765R1 1SDA071395R1 E1.2N 800 Ekip Touch LSIG 1SDA070766R1 1SDA071396R1 E1.2N 800 Ekip Hi-Touch LSI 1SDA070768R1 1SDA071398R1 E1.2N 800 Ekip Hi-Touch LSIG 1SDA070769R1 1SDA071399R1 E1.2N 1000 Ekip Dip LI 1SDA070801R1 1SDA071431R1 E1.2N 1000 Ekip Dip LSI 1SDA070802R1 1SDA071432R1 E1.2N 1000 Ekip Dip LSIG 1SDA070803R1 1SDA071433R1 E1.2N 1000 Ekip Touch LI 1SDA070804R1 1SDA071434R1 E1.2N 1000 Ekip Touch LSI 1SDA070805R1 1SDA071435R1 E1.2N 1000 Ekip Touch LSIG 1SDA070806R1 1SDA071436R1 E1.2N 1000 Ekip Hi-Touch LSI 1SDA070808R1 1SDA071438R1 E1.2N 1000 Ekip Hi-Touch LSIG 1SDA070809R1 1SDA071439R1 E1.2N 1250 Ekip Dip LI 1SDA070841R1 1SDA071471R1 E1.2N 1250 Ekip Dip LSI 1SDA070842R1 1SDA071472R1 E1.2N 1250 Ekip Dip LSIG 1SDA070843R1 1SDA071473R1 E1.2N 1250 Ekip Touch LI 1SDA070844R1 1SDA071474R1 E1.2N 1250 Ekip Touch LSI 1SDA070845R1 1SDA071475R1 E1.2N 1250 Ekip Touch LSIG 1SDA070846R1 1SDA071476R1 E1.2N 1250 Ekip Hi-Touch LSI 1SDA070848R1 1SDA071478R1 E1.2N 1250 Ekip Hi-Touch LSIG 1SDA070849R1 1SDA071479R1 E1.2N 1600 Ekip Dip LI 1SDA070881R1 1SDA071511R1 E1.2N 1600 Ekip Dip LSI 1SDA070882R1 1SDA071512R1 E1.2N 1600 Ekip Dip LSIG 1SDA070883R1 1SDA071513R1 E1.2N 1600 Ekip Touch LI 1SDA070884R1 1SDA071514R1 E1.2N 1600 Ekip Touch LSI 1SDA070885R1 1SDA071515R1 E1.2N 1600 Ekip Touch LSIG 1SDA070886R1 1SDA071516R1 E1.2N 1600 Ekip Hi-Touch LSI 1SDA070888R1 1SDA071518R1 E1.2N 1600 Ekip Hi-Touch LSIG 1SDA070889R1 1SDA071519R1 9/8 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 8 15/04/2013 18:00:43 1SDC200661F001 SACE Emax E1.2L • Front terminals (F) Size E1.2L Iu 630 800 1000 1250 Icu Icw (440 V) (1s) Type 130 130 130 130 15 15 15 15 3 Poles 4 Poles Code Code E1.2L 630 Ekip Dip LI 1SDA070731R1 1SDA071361R1 E1.2L 630 Ekip Dip LSI 1SDA070732R1 1SDA071362R1 E1.2L 630 Ekip Dip LSIG 1SDA070733R1 1SDA071363R1 E1.2L 630 Ekip Touch LI 1SDA070734R1 1SDA071364R1 E1.2L 630 Ekip Touch LSI 1SDA070735R1 1SDA071365R1 E1.2L 630 Ekip Touch LSIG 1SDA070736R1 1SDA071366R1 E1.2L 630 Ekip Hi-Touch LSI 1SDA070738R1 1SDA071368R1 E1.2L 630 Ekip Hi-Touch LSIG 1SDA070739R1 1SDA071369R1 E1.2L 800 Ekip Dip LI 1SDA070771R1 1SDA071401R1 E1.2L 800 Ekip Dip LSI 1SDA070772R1 1SDA071402R1 E1.2L 800 Ekip Dip LSIG 1SDA070773R1 1SDA071403R1 E1.2L 800 Ekip Touch LI 1SDA070774R1 1SDA071404R1 E1.2L 800 Ekip Touch LSI 1SDA070775R1 1SDA071405R1 E1.2L 800 Ekip Touch LSIG 1SDA070776R1 1SDA071406R1 E1.2L 800 Ekip Hi-Touch LSI 1SDA070778R1 1SDA071408R1 E1.2L 800 Ekip Hi-Touch LSIG 1SDA070779R1 1SDA071409R1 E1.2L 1000 Ekip Dip LI 1SDA070811R1 1SDA071441R1 E1.2L 1000 Ekip Dip LSI 1SDA070812R1 1SDA071442R1 E1.2L 1000 Ekip Dip LSIG 1SDA070813R1 1SDA071443R1 E1.2L 1000 Ekip Touch LI 1SDA070814R1 1SDA071444R1 E1.2L 1000 Ekip Touch LSI 1SDA070815R1 1SDA071445R1 E1.2L 1000 Ekip Touch LSIG 1SDA070816R1 1SDA071446R1 E1.2L 1000 Ekip Hi-Touch LSI 1SDA070818R1 1SDA071448R1 E1.2L 1000 Ekip Hi-Touch LSIG 1SDA070819R1 1SDA071449R1 E1.2L 1250 Ekip Dip LI 1SDA070851R1 1SDA071481R1 E1.2L 1250 Ekip Dip LSI 1SDA070852R1 1SDA071482R1 E1.2L 1250 Ekip Dip LSIG 1SDA070853R1 1SDA071483R1 E1.2L 1250 Ekip Touch LI 1SDA070854R1 1SDA071484R1 E1.2L 1250 Ekip Touch LSI 1SDA070855R1 1SDA071485R1 E1.2L 1250 Ekip Touch LSIG 1SDA070856R1 1SDA071486R1 E1.2L 1250 Ekip Hi-Touch LSI 1SDA070858R1 1SDA071488R1 E1.2L 1250 Ekip Hi-Touch LSIG 1SDA070859R1 1SDA071489R1 9 ABB Catalogue | 1SDC200023D0201 | 9/9 Emax2_cap09.indd 9 15/04/2013 18:00:43 Automatic circuit-breakers Fixed version for power distribution 1SDC200662F001 SACE Emax E2.2B • Orientable rear terminals (HR) Size E2.2B Iu 1600 2000 Icu Icw (440 V) (1s) Type 42 42 42 42 3 Poles 4 Poles Code Code E2.2B 1600 Ekip Dip LI 1SDA070981R1 1SDA071611R1 E2.2B 1600 Ekip Dip LSI 1SDA070982R1 1SDA071612R1 E2.2B 1600 Ekip Dip LSIG 1SDA070983R1 1SDA071613R1 E2.2B 1600 Ekip Touch LI 1SDA070984R1 1SDA071614R1 E2.2B 1600 Ekip Touch LSI 1SDA070985R1 1SDA071615R1 E2.2B 1600 Ekip Touch LSIG 1SDA070986R1 1SDA071616R1 E2.2B 1600 Ekip Hi-Touch LSI 1SDA070988R1 1SDA071618R1 E2.2B 1600 Ekip Hi-Touch LSIG 1SDA070989R1 1SDA071619R1 E2.2B 2000 Ekip Dip LI 1SDA071021R1 1SDA071651R1 E2.2B 2000 Ekip Dip LSI 1SDA071022R1 1SDA071652R1 E2.2B 2000 Ekip Dip LSIG 1SDA071023R1 1SDA071653R1 E2.2B 2000 Ekip Touch LI 1SDA071024R1 1SDA071654R1 E2.2B 2000 Ekip Touch LSI 1SDA071025R1 1SDA071655R1 E2.2B 2000 Ekip Touch LSIG 1SDA071026R1 1SDA071656R1 E2.2B 2000 Ekip Hi-Touch LSI 1SDA071028R1 1SDA071658R1 E2.2B 2000 Ekip Hi-Touch LSIG 1SDA071029R1 1SDA071659R1 9 9/10 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 10 15/04/2013 18:00:44 1SDC200662F001 SACE Emax E2.2N • Orientable rear terminals (HR) Size E2.2N Iu 800 1000 1250 1600 2000 2500 Icu Icw (440 V) (1s) Type 66 66 66 66 66 66 66 66 66 66 66 66 3 Poles 4 Poles Code Code E2.2N 800 Ekip Dip LI 1SDA070891R1 1SDA071521R1 E2.2N 800 Ekip Dip LSI 1SDA070892R1 1SDA071522R1 E2.2N 800 Ekip Dip LSIG 1SDA070893R1 1SDA071523R1 E2.2N 800 Ekip Touch LI 1SDA070894R1 1SDA071524R1 E2.2N 800 Ekip Touch LSI 1SDA070895R1 1SDA071525R1 E2.2N 800 Ekip Touch LSIG 1SDA070896R1 1SDA071526R1 E2.2N 800 Ekip Hi-Touch LSI 1SDA070898R1 1SDA071528R1 E2.2N 800 Ekip Hi-Touch LSIG 1SDA070899R1 1SDA071529R1 E2.2N 1000 Ekip Dip LI 1SDA070921R1 1SDA071551R1 E2.2N 1000 Ekip Dip LSI 1SDA070922R1 1SDA071552R1 E2.2N 1000 Ekip Dip LSIG 1SDA070923R1 1SDA071553R1 E2.2N 1000 Ekip Touch LI 1SDA070924R1 1SDA071554R1 E2.2N 1000 Ekip Touch LSI 1SDA070925R1 1SDA071555R1 E2.2N 1000 Ekip Touch LSIG 1SDA070926R1 1SDA071556R1 E2.2N 1000 Ekip Hi-Touch LSI 1SDA070928R1 1SDA071558R1 E2.2N 1000 Ekip Hi-Touch LSIG 1SDA070929R1 1SDA071559R1 E2.2N 1250 Ekip Dip LI 1SDA070951R1 1SDA071581R1 E2.2N 1250 Ekip Dip LSI 1SDA070952R1 1SDA071582R1 E2.2N 1250 Ekip Dip LSIG 1SDA070953R1 1SDA071583R1 E2.2N 1250 Ekip Touch LI 1SDA070954R1 1SDA071584R1 E2.2N 1250 Ekip Touch LSI 1SDA070955R1 1SDA071585R1 E2.2N 1250 Ekip Touch LSIG 1SDA070956R1 1SDA071586R1 E2.2N 1250 Ekip Hi-Touch LSI 1SDA070958R1 1SDA071588R1 E2.2N 1250 Ekip Hi-Touch LSIG 1SDA070959R1 1SDA071589R1 E2.2N 1600 Ekip Dip LI 1SDA070991R1 1SDA071621R1 E2.2N 1600 Ekip Dip LSI 1SDA070992R1 1SDA071622R1 E2.2N 1600 Ekip Dip LSIG 1SDA070993R1 1SDA071623R1 E2.2N 1600 Ekip Touch LI 1SDA070994R1 1SDA071624R1 E2.2N 1600 Ekip Touch LSI 1SDA070995R1 1SDA071625R1 E2.2N 1600 Ekip Touch LSIG 1SDA070996R1 1SDA071626R1 E2.2N 1600 Ekip Hi-Touch LSI 1SDA070998R1 1SDA071628R1 E2.2N 1600 Ekip Hi-Touch LSIG 1SDA070999R1 1SDA071629R1 E2.2N 2000 Ekip Dip LI 1SDA071031R1 1SDA071661R1 E2.2N 2000 Ekip Dip LSI 1SDA071032R1 1SDA071662R1 E2.2N 2000 Ekip Dip LSIG 1SDA071033R1 1SDA071663R1 E2.2N 2000 Ekip Touch LI 1SDA071034R1 1SDA071664R1 E2.2N 2000 Ekip Touch LSI 1SDA071035R1 1SDA071665R1 E2.2N 2000 Ekip Touch LSIG 1SDA071036R1 1SDA071666R1 E2.2N 2000 Ekip Hi-Touch LSI 1SDA071038R1 1SDA071668R1 E2.2N 2000 Ekip Hi-Touch LSIG 1SDA071039R1 1SDA071669R1 E2.2N 2500 Ekip Dip LI 1SDA071061R1 1SDA071691R1 E2.2N 2500 Ekip Dip LSI 1SDA071062R1 1SDA071692R1 E2.2N 2500 Ekip Dip LSIG 1SDA071063R1 1SDA071693R1 E2.2N 2500 Ekip Touch LI 1SDA071064R1 1SDA071694R1 E2.2N 2500 Ekip Touch LSI 1SDA071065R1 1SDA071695R1 E2.2N 2500 Ekip Touch LSIG 1SDA071066R1 1SDA071696R1 E2.2N 2500 Ekip Hi-Touch LSI 1SDA071068R1 1SDA071698R1 E2.2N 2500 Ekip Hi-Touch LSIG 1SDA071069R1 1SDA071699R1 9 ABB Catalogue | 1SDC200023D0201 | 9/11 Emax2_cap09.indd 11 15/04/2013 18:00:44 Automatic circuit-breakers Fixed version for power distribution 1SDC200662F001 SACE Emax E2.2S • Orientable rear terminals (HR) Size E2.2S Iu 250 800 1000 Icu Icw (440 V) (1s) Type 85 85 85 66 66 66 9 1250 85 66 3 Poles 4 Poles Code Code E2.2S 250 Ekip Dip LI 1SDA073628R1 1SDA073638R1 E2.2S 250 Ekip Dip LSI 1SDA073629R1 1SDA073639R1 E2.2S 250 Ekip Dip LSIG 1SDA073630R1 1SDA073640R1 E2.2S 250 Ekip Touch LI 1SDA073631R1 1SDA073641R1 E2.2S 250 Ekip Touch LSI 1SDA073632R1 1SDA073642R1 E2.2S 250 Ekip Touch LSIG 1SDA073633R1 1SDA073643R1 E2.2S 250 Ekip Hi-Touch LSI 1SDA073635R1 1SDA073645R1 E2.2S 250 Ekip Hi-Touch LSIG 1SDA073636R1 1SDA073646R1 E2.2S 800 Ekip Dip LI 1SDA070901R1 1SDA071531R1 E2.2S 800 Ekip Dip LSI 1SDA070902R1 1SDA071532R1 E2.2S 800 Ekip Dip LSIG 1SDA070903R1 1SDA071533R1 E2.2S 800 Ekip Touch LI 1SDA070904R1 1SDA071534R1 E2.2S 800 Ekip Touch LSI 1SDA070905R1 1SDA071535R1 E2.2S 800 Ekip Touch LSIG 1SDA070906R1 1SDA071536R1 E2.2S 800 Ekip Hi-Touch LSI 1SDA070908R1 1SDA071538R1 E2.2S 800 Ekip Hi-Touch LSIG 1SDA070909R1 1SDA071539R1 E2.2S 1000 Ekip Dip LI 1SDA070931R1 1SDA071561R1 E2.2S 1000 Ekip Dip LSI 1SDA070932R1 1SDA071562R1 E2.2S 1000 Ekip Dip LSIG 1SDA070933R1 1SDA071563R1 E2.2S 1000 Ekip Touch LI 1SDA070934R1 1SDA071564R1 E2.2S 1000 Ekip Touch LSI 1SDA070935R1 1SDA071565R1 E2.2S 1000 Ekip Touch LSIG 1SDA070936R1 1SDA071566R1 E2.2S 1000 Ekip Hi-Touch LSI 1SDA070938R1 1SDA071568R1 E2.2S 1000 Ekip Hi-Touch LSIG 1SDA070939R1 1SDA071569R1 E2.2S 1250 Ekip Dip LI 1SDA070961R1 1SDA071591R1 E2.2S 1250 Ekip Dip LSI 1SDA070962R1 1SDA071592R1 E2.2S 1250 Ekip Dip LSIG 1SDA070963R1 1SDA071593R1 E2.2S 1250 Ekip Touch LI 1SDA070964R1 1SDA071594R1 E2.2S 1250 Ekip Touch LSI 1SDA070965R1 1SDA071595R1 E2.2S 1250 Ekip Touch LSIG 1SDA070966R1 1SDA071596R1 E2.2S 1250 Ekip Hi-Touch LSI 1SDA070968R1 1SDA071598R1 E2.2S 1250 Ekip Hi-Touch LSIG 1SDA070969R1 1SDA071599R1 9/12 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 12 15/04/2013 18:00:44 1SDC200662F001 SACE Emax E2.2S • Orientable rear terminals (HR) Size E2.2S Iu 1600 2000 2500 Icu Icw (440 V) (1s) Type 85 85 85 66 66 66 3 Poles 4 Poles Code Code E2.2S 1600 Ekip Dip LI 1SDA071001R1 1SDA071631R1 E2.2S 1600 Ekip Dip LSI 1SDA071002R1 1SDA071632R1 E2.2S 1600 Ekip Dip LSIG 1SDA071003R1 1SDA071633R1 E2.2S 1600 Ekip Touch LI 1SDA071004R1 1SDA071634R1 E2.2S 1600 Ekip Touch LSI 1SDA071005R1 1SDA071635R1 E2.2S 1600 Ekip Touch LSIG 1SDA071006R1 1SDA071636R1 E2.2S 1600 Ekip Hi-Touch LSI 1SDA071008R1 1SDA071638R1 E2.2S 1600 Ekip Hi-Touch LSIG 1SDA071009R1 1SDA071639R1 E2.2S 2000 Ekip Dip LI 1SDA071041R1 1SDA071671R1 E2.2S 2000 Ekip Dip LSI 1SDA071042R1 1SDA071672R1 E2.2S 2000 Ekip Dip LSIG 1SDA071043R1 1SDA071673R1 E2.2S 2000 Ekip Touch LI 1SDA071044R1 1SDA071674R1 E2.2S 2000 Ekip Touch LSI 1SDA071045R1 1SDA071675R1 E2.2S 2000 Ekip Touch LSIG 1SDA071046R1 1SDA071676R1 E2.2S 2000 Ekip Hi-Touch LSI 1SDA071048R1 1SDA071678R1 E2.2S 2000 Ekip Hi-Touch LSIG 1SDA071049R1 1SDA071679R1 E2.2S 2500 Ekip Dip LI 1SDA071071R1 1SDA071701R1 E2.2S 2500 Ekip Dip LSI 1SDA071072R1 1SDA071702R1 E2.2S 2500 Ekip Dip LSIG 1SDA071073R1 1SDA071703R1 E2.2S 2500 Ekip Touch LI 1SDA071074R1 1SDA071704R1 E2.2S 2500 Ekip Touch LSI 1SDA071075R1 1SDA071705R1 E2.2S 2500 Ekip Touch LSIG 1SDA071076R1 1SDA071706R1 E2.2S 2500 Ekip Hi-Touch LSI 1SDA071078R1 1SDA071708R1 E2.2S 2500 Ekip Hi-Touch LSIG 1SDA071079R1 1SDA071709R1 9 ABB Catalogue | 1SDC200023D0201 | 9/13 Emax2_cap09.indd 13 15/04/2013 18:00:45 Automatic circuit-breakers Fixed version for power distribution 1SDC200662F001 SACE Emax E2.2H • Orientable rear terminals (HR) Size E2.2H Iu 800 1000 1250 Icu Icw (440 V) (1s) Type 100 100 100 85 85 85 9 1600 2000 2500 100 100 100 85 85 85 3 Poles 4 Poles Code Code E2.2H 800 Ekip Dip LI 1SDA070911R1 1SDA071541R1 E2.2H 800 Ekip Dip LSI 1SDA070912R1 1SDA071542R1 E2.2H 800 Ekip Dip LSIG 1SDA070913R1 1SDA071543R1 E2.2H 800 Ekip Touch LI 1SDA070914R1 1SDA071544R1 E2.2H 800 Ekip Touch LSI 1SDA070915R1 1SDA071545R1 E2.2H 800 Ekip Touch LSIG 1SDA070916R1 1SDA071546R1 E2.2H 800 Ekip Hi-Touch LSI 1SDA070918R1 1SDA071548R1 E2.2H 800 Ekip Hi-Touch LSIG 1SDA070919R1 1SDA071549R1 E2.2H 1000 Ekip Dip LI 1SDA070941R1 1SDA071571R1 E2.2H 1000 Ekip Dip LSI 1SDA070942R1 1SDA071572R1 E2.2H 1000 Ekip Dip LSIG 1SDA070943R1 1SDA071573R1 E2.2H 1000 Ekip Touch LI 1SDA070944R1 1SDA071574R1 E2.2H 1000 Ekip Touch LSI 1SDA070945R1 1SDA071575R1 E2.2H 1000 Ekip Touch LSIG 1SDA070946R1 1SDA071576R1 E2.2H 1000 Ekip Hi-Touch LSI 1SDA070948R1 1SDA071578R1 E2.2H 1000 Ekip Hi-Touch LSIG 1SDA070949R1 1SDA071579R1 E2.2H 1250 Ekip Dip LI 1SDA070971R1 1SDA071601R1 E2.2H 1250 Ekip Dip LSI 1SDA070972R1 1SDA071602R1 E2.2H 1250 Ekip Dip LSIG 1SDA070973R1 1SDA071603R1 E2.2H 1250 Ekip Touch LI 1SDA070974R1 1SDA071604R1 E2.2H 1250 Ekip Touch LSI 1SDA070975R1 1SDA071605R1 E2.2H 1250 Ekip Touch LSIG 1SDA070976R1 1SDA071606R1 E2.2H 1250 Ekip Hi-Touch LSI 1SDA070978R1 1SDA071608R1 E2.2H 1250 Ekip Hi-Touch LSIG 1SDA070979R1 1SDA071609R1 E2.2H 1600 Ekip Dip LI 1SDA071011R1 1SDA071641R1 E2.2H 1600 Ekip Dip LSI 1SDA071012R1 1SDA071642R1 E2.2H 1600 Ekip Dip LSIG 1SDA071013R1 1SDA071643R1 E2.2H 1600 Ekip Touch LI 1SDA071014R1 1SDA071644R1 E2.2H 1600 Ekip Touch LSI 1SDA071015R1 1SDA071645R1 E2.2H 1600 Ekip Touch LSIG 1SDA071016R1 1SDA071646R1 E2.2H 1600 Ekip Hi-Touch LSI 1SDA071018R1 1SDA071648R1 E2.2H 1600 Ekip Hi-Touch LSIG 1SDA071019R1 1SDA071649R1 E2.2H 2000 Ekip Dip LI 1SDA071051R1 1SDA071681R1 E2.2H 2000 Ekip Dip LSI 1SDA071052R1 1SDA071682R1 E2.2H 2000 Ekip Dip LSIG 1SDA071053R1 1SDA071683R1 E2.2H 2000 Ekip Touch LI 1SDA071054R1 1SDA071684R1 E2.2H 2000 Ekip Touch LSI 1SDA071055R1 1SDA071685R1 E2.2H 2000 Ekip Touch LSIG 1SDA071056R1 1SDA071686R1 E2.2H 2000 Ekip Hi-Touch LSI 1SDA071058R1 1SDA071688R1 E2.2H 2000 Ekip Hi-Touch LSIG 1SDA071059R1 1SDA071689R1 E2.2H 2500 Ekip Dip LI 1SDA071081R1 1SDA071711R1 E2.2H 2500 Ekip Dip LSI 1SDA071082R1 1SDA071712R1 E2.2H 2500 Ekip Dip LSIG 1SDA071083R1 1SDA071713R1 E2.2H 2500 Ekip Touch LI 1SDA071084R1 1SDA071714R1 E2.2H 2500 Ekip Touch LSI 1SDA071085R1 1SDA071715R1 E2.2H 2500 Ekip Touch LSIG 1SDA071086R1 1SDA071716R1 E2.2H 2500 Ekip Hi-Touch LSI 1SDA071088R1 1SDA071718R1 E2.2H 2500 Ekip Hi-Touch LSIG 1SDA071089R1 1SDA071719R1 9/14 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 14 15/04/2013 18:00:45 1SDC200663F001 SACE Emax E4.2N-S • Orientable rear terminals (HR) Size E4.2N Iu 3200 4000 E4.2S 3200 4000 Icu Icw (440 V) (1s) Type 66 66 85 85 66 66 66 66 3 Poles 4 Poles Code Code E4.2N 3200 Ekip Dip LI 1SDA071141R1 1SDA071771R1 E4.2N 3200 Ekip Dip LSI 1SDA071142R1 1SDA071772R1 E4.2N 3200 Ekip Dip LSIG 1SDA071143R1 1SDA071773R1 E4.2N 3200 Ekip Touch LI 1SDA071144R1 1SDA071774R1 E4.2N 3200 Ekip Touch LSI 1SDA071145R1 1SDA071775R1 E4.2N 3200 Ekip Touch LSIG 1SDA071146R1 1SDA071776R1 E4.2N 3200 Ekip Hi-Touch LSI 1SDA071148R1 1SDA071778R1 E4.2N 3200 Ekip Hi-Touch LSIG 1SDA071149R1 1SDA071779R1 E4.2N 4000 Ekip Dip LI 1SDA071191R1 1SDA071821R1 E4.2N 4000 Ekip Dip LSI 1SDA071192R1 1SDA071822R1 E4.2N 4000 Ekip Dip LSIG 1SDA071193R1 1SDA071823R1 E4.2N 4000 Ekip Touch LI 1SDA071194R1 1SDA071824R1 E4.2N 4000 Ekip Touch LSI 1SDA071195R1 1SDA071825R1 E4.2N 4000 Ekip Touch LSIG 1SDA071196R1 1SDA071826R1 E4.2N 4000 Ekip Hi-Touch LSI 1SDA071198R1 1SDA071828R1 E4.2N 4000 Ekip Hi-Touch LSIG 1SDA071199R1 1SDA071829R1 E4.2S 3200 Ekip Dip LI 1SDA071151R1 1SDA071781R1 E4.2S 3200 Ekip Dip LSI 1SDA071152R1 1SDA071782R1 E4.2S 3200 Ekip Dip LSIG 1SDA071153R1 1SDA071783R1 E4.2S 3200 Ekip Touch LI 1SDA071154R1 1SDA071784R1 E4.2S 3200 Ekip Touch LSI 1SDA071155R1 1SDA071785R1 E4.2S 3200 Ekip Touch LSIG 1SDA071156R1 1SDA071786R1 E4.2S 3200 Ekip Hi-Touch LSI 1SDA071158R1 1SDA071788R1 E4.2S 3200 Ekip Hi-Touch LSIG 1SDA071159R1 1SDA071789R1 E4.2S 4000 Ekip Dip LI 1SDA071201R1 1SDA071831R1 E4.2S 4000 Ekip Dip LSI 1SDA071202R1 1SDA071832R1 E4.2S 4000 Ekip Dip LSIG 1SDA071203R1 1SDA071833R1 E4.2S 4000 Ekip Touch LI 1SDA071204R1 1SDA071834R1 E4.2S 4000 Ekip Touch LSI 1SDA071205R1 1SDA071835R1 E4.2S 4000 Ekip Touch LSIG 1SDA071206R1 1SDA071836R1 E4.2S 4000 Ekip Hi-Touch LSI 1SDA071208R1 1SDA071838R1 E4.2S 4000 Ekip Hi-Touch LSIG 1SDA071209R1 1SDA071839R1 9 ABB Catalogue | 1SDC200023D0201 | 9/15 Emax2_cap09.indd 15 15/04/2013 18:00:46 Automatic circuit-breakers Fixed version for power distribution 1SDC200663F001 SACE Emax E4.2H-V • Orientable rear terminals (HR) Size E4.2H Iu 3200 4000 E4.2V 2000 Icu Icw (440 V) (1s) Type 100 100 150 85 85 100 9 2500 3200 4000 150 150 150 100 100 100 3 Poles 4 Poles Code Code E4.2H 3200 Ekip Dip LI 1SDA071161R1 1SDA071791R1 E4.2H 3200 Ekip Dip LSI 1SDA071162R1 1SDA071792R1 E4.2H 3200 Ekip Dip LSIG 1SDA071163R1 1SDA071793R1 E4.2H 3200 Ekip Touch LI 1SDA071164R1 1SDA071794R1 E4.2H 3200 Ekip Touch LSI 1SDA071165R1 1SDA071795R1 E4.2H 3200 Ekip Touch LSIG 1SDA071166R1 1SDA071796R1 E4.2H 3200 Ekip Hi-Touch LSI 1SDA071168R1 1SDA071798R1 E4.2H 3200 Ekip Hi-Touch LSIG 1SDA071169R1 1SDA071799R1 E4.2H 4000 Ekip Dip LI 1SDA071211R1 1SDA071841R1 E4.2H 4000 Ekip Dip LSI 1SDA071212R1 1SDA071842R1 E4.2H 4000 Ekip Dip LSIG 1SDA071213R1 1SDA071843R1 E4.2H 4000 Ekip Touch LI 1SDA071214R1 1SDA071844R1 E4.2H 4000 Ekip Touch LSI 1SDA071215R1 1SDA071845R1 E4.2H 4000 Ekip Touch LSIG 1SDA071216R1 1SDA071846R1 E4.2H 4000 Ekip Hi-Touch LSI 1SDA071218R1 1SDA071848R1 E4.2H 4000 Ekip Hi-Touch LSIG 1SDA071219R1 1SDA071849R1 E4.2V 2000 Ekip Dip LI 1SDA071101R1 1SDA071731R1 E4.2V 2000 Ekip Dip LSI 1SDA071102R1 1SDA071732R1 E4.2V 2000 Ekip Dip LSIG 1SDA071103R1 1SDA071733R1 E4.2V 2000 Ekip Touch LI 1SDA071104R1 1SDA071734R1 E4.2V 2000 Ekip Touch LSI 1SDA071105R1 1SDA071735R1 E4.2V 2000 Ekip Touch LSIG 1SDA071106R1 1SDA071736R1 E4.2V 2000 Ekip Hi-Touch LSI 1SDA071108R1 1SDA071738R1 E4.2V 2000 Ekip Hi-Touch LSIG 1SDA071109R1 1SDA071739R1 E4.2V 2500 Ekip Dip LI 1SDA071121R1 1SDA071751R1 E4.2V 2500 Ekip Dip LSI 1SDA071122R1 1SDA071752R1 E4.2V 2500 Ekip Dip LSIG 1SDA071123R1 1SDA071753R1 E4.2V 2500 Ekip Touch LI 1SDA071124R1 1SDA071754R1 E4.2V 2500 Ekip Touch LSI 1SDA071125R1 1SDA071755R1 E4.2V 2500 Ekip Touch LSIG 1SDA071126R1 1SDA071756R1 E4.2V 2500 Ekip Hi-Touch LSI 1SDA071128R1 1SDA071758R1 E4.2V 2500 Ekip Hi-Touch LSIG 1SDA071129R1 1SDA071759R1 E4.2V 3200 Ekip Dip LI 1SDA071171R1 1SDA071801R1 E4.2V 3200 Ekip Dip LSI 1SDA071172R1 1SDA071802R1 E4.2V 3200 Ekip Dip LSIG 1SDA071173R1 1SDA071803R1 E4.2V 3200 Ekip Touch LI 1SDA071174R1 1SDA071804R1 E4.2V 3200 Ekip Touch LSI 1SDA071175R1 1SDA071805R1 E4.2V 3200 Ekip Touch LSIG 1SDA071176R1 1SDA071806R1 E4.2V 3200 Ekip Hi-Touch LSI 1SDA071178R1 1SDA071808R1 E4.2V 3200 Ekip Hi-Touch LSIG 1SDA071179R1 1SDA071809R1 E4.2V 4000 Ekip Dip LI 1SDA071221R1 1SDA071851R1 E4.2V 4000 Ekip Dip LSI 1SDA071222R1 1SDA071852R1 E4.2V 4000 Ekip Dip LSIG 1SDA071223R1 1SDA071853R1 E4.2V 4000 Ekip Touch LI 1SDA071224R1 1SDA071854R1 E4.2V 4000 Ekip Touch LSI 1SDA071225R1 1SDA071855R1 E4.2V 4000 Ekip Touch LSIG 1SDA071226R1 1SDA071856R1 E4.2V 4000 Ekip Hi-Touch LSI 1SDA071228R1 1SDA071858R1 E4.2V 4000 Ekip Hi-Touch LSIG 1SDA071229R1 1SDA071859R1 9/16 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 16 15/04/2013 18:00:46 SACE Emax E6.2H-V • Orientable rear terminals (HR) 1SDC200664F001 Size E6.2H Iu 4000 5000 6300 E6.2V 4000 5000 6300 Icu Icw (440 V) (1s) Type 100 100 100 150 150 150 100 100 100 100 100 100 3 Poles 4 Poles Code Code E6.2H 4000 Ekip Dip LI 1SDA071231R1 1SDA071861R1 E6.2H 4000 Ekip Dip LSI 1SDA071232R1 1SDA071862R1 E6.2H 4000 Ekip Dip LSIG 1SDA071233R1 1SDA071863R1 E6.2H 4000 Ekip Touch LI 1SDA071234R1 1SDA071864R1 E6.2H 4000 Ekip Touch LSI 1SDA071235R1 1SDA071865R1 E6.2H 4000 Ekip Touch LSIG 1SDA071236R1 1SDA071866R1 E6.2H 4000 Ekip Hi-Touch LSI 1SDA071238R1 1SDA071868R1 E6.2H 4000 Ekip Hi-Touch LSIG 1SDA071239R1 1SDA071869R1 E6.2H 5000 Ekip Dip LI 1SDA071261R1 1SDA071891R1 E6.2H 5000 Ekip Dip LSI 1SDA071262R1 1SDA071892R1 E6.2H 5000 Ekip Dip LSIG 1SDA071263R1 1SDA071893R1 E6.2H 5000 Ekip Touch LI 1SDA071264R1 1SDA071894R1 E6.2H 5000 Ekip Touch LSI 1SDA071265R1 1SDA071895R1 E6.2H 5000 Ekip Touch LSIG 1SDA071266R1 1SDA071896R1 E6.2H 5000 Ekip Hi-Touch LSI 1SDA071268R1 1SDA071898R1 E6.2H 5000 Ekip Hi-Touch LSIG 1SDA071269R1 1SDA071899R1 E6.2H 6300 Ekip Dip LI 1SDA071291R1 1SDA071921R1 E6.2H 6300 Ekip Dip LSI 1SDA071292R1 1SDA071922R1 E6.2H 6300 Ekip Dip LSIG 1SDA071293R1 1SDA071923R1 E6.2H 6300 Ekip Touch LI 1SDA071294R1 1SDA071924R1 E6.2H 6300 Ekip Touch LSI 1SDA071295R1 1SDA071925R1 E6.2H 6300 Ekip Touch LSIG 1SDA071296R1 1SDA071926R1 E6.2H 6300 Ekip Hi-Touch LSI 1SDA071298R1 1SDA071928R1 E6.2H 6300 Ekip Hi-Touch LSIG 1SDA071299R1 1SDA071929R1 E6.2V 4000 Ekip Dip LI 1SDA071241R1 1SDA071871R1 E6.2V 4000 Ekip Dip LSI 1SDA071242R1 1SDA071872R1 E6.2V 4000 Ekip Dip LSIG 1SDA071243R1 1SDA071873R1 E6.2V 4000 Ekip Touch LI 1SDA071244R1 1SDA071874R1 E6.2V 4000 Ekip Touch LSI 1SDA071245R1 1SDA071875R1 E6.2V 4000 Ekip Touch LSIG 1SDA071246R1 1SDA071876R1 E6.2V 4000 Ekip Hi-Touch LSI 1SDA071248R1 1SDA071878R1 E6.2V 4000 Ekip Hi-Touch LSIG 1SDA071249R1 1SDA071879R1 E6.2V 5000 Ekip Dip LI 1SDA071271R1 1SDA071901R1 E6.2V 5000 Ekip Dip LSI 1SDA071272R1 1SDA071902R1 E6.2V 5000 Ekip Dip LSIG 1SDA071273R1 1SDA071903R1 E6.2V 5000 Ekip Touch LI 1SDA071274R1 1SDA071904R1 E6.2V 5000 Ekip Touch LSI 1SDA071275R1 1SDA071905R1 E6.2V 5000 Ekip Touch LSIG 1SDA071276R1 1SDA071906R1 E6.2V 5000 Ekip Hi-Touch LSI 1SDA071278R1 1SDA071908R1 E6.2V 5000 Ekip Hi-Touch LSIG 1SDA071279R1 1SDA071909R1 E6.2V 6300 Ekip Dip LI 1SDA071301R1 1SDA071931R1 E6.2V 6300 Ekip Dip LSI 1SDA071302R1 1SDA071932R1 E6.2V 6300 Ekip Dip LSIG 1SDA071303R1 1SDA071933R1 E6.2V 6300 Ekip Touch LI 1SDA071304R1 1SDA071934R1 E6.2V 6300 Ekip Touch LSI 1SDA071305R1 1SDA071935R1 E6.2V 6300 Ekip Touch LSIG 1SDA071306R1 1SDA071936R1 E6.2V 6300 Ekip Hi-Touch LSI 1SDA071308R1 1SDA071938R1 E6.2V 6300 Ekip Hi-Touch LSIG 1SDA071309R1 1SDA071939R1 9 ABB Catalogue | 1SDC200023D0201 | 9/17 Emax2_cap09.indd 17 15/04/2013 18:00:47 Automatic circuit-breakers Fixed version for power distribution SACE Emax E6.2X • Orientable rear terminals (HR) 1SDC200664F001 Size E6.2X Iu 4000 5000 6300 9 Icu Icw (440 V) (1s) Type 200 200 200 120 120 120 3 Poles 4 Poles Code Code E6.2X 4000 Ekip Dip LI 1SDA071251R1 1SDA071881R1 E6.2X 4000 Ekip Dip LSI 1SDA071252R1 1SDA071882R1 E6.2X 4000 Ekip Dip LSIG 1SDA071253R1 1SDA071883R1 E6.2X 4000 Ekip Touch LI 1SDA071254R1 1SDA071884R1 E6.2X 4000 Ekip Touch LSI 1SDA071255R1 1SDA071885R1 E6.2X 4000 Ekip Touch LSIG 1SDA071256R1 1SDA071886R1 E6.2X 4000 Ekip Hi-Touch LSI 1SDA071258R1 1SDA071888R1 E6.2X 4000 Ekip Hi-Touch LSIG 1SDA071259R1 1SDA071889R1 E6.2X 5000 Ekip Dip LI 1SDA071281R1 1SDA071911R1 E6.2X 5000 Ekip Dip LSI 1SDA071282R1 1SDA071912R1 E6.2X 5000 Ekip Dip LSIG 1SDA071283R1 1SDA071913R1 E6.2X 5000 Ekip Touch LI 1SDA071284R1 1SDA071914R1 E6.2X 5000 Ekip Touch LSI 1SDA071285R1 1SDA071915R1 E6.2X 5000 Ekip Touch LSIG 1SDA071286R1 1SDA071916R1 E6.2X 5000 Ekip Hi-Touch LSI 1SDA071288R1 1SDA071918R1 E6.2X 5000 Ekip Hi-Touch LSIG 1SDA071289R1 1SDA071919R1 E6.2X 6300 Ekip Dip LI 1SDA071311R1 1SDA071941R1 E6.2X 6300 Ekip Dip LSI 1SDA071312R1 1SDA071942R1 E6.2X 6300 Ekip Dip LSIG 1SDA071313R1 1SDA071943R1 E6.2X 6300 Ekip Touch LI 1SDA071314R1 1SDA071944R1 E6.2X 6300 Ekip Touch LSI 1SDA071315R1 1SDA071945R1 E6.2X 6300 Ekip Touch LSIG 1SDA071316R1 1SDA071946R1 E6.2X 6300 Ekip Hi-Touch LSI 1SDA071318R1 1SDA071948R1 E6.2X 6300 Ekip Hi-Touch LSIG 1SDA071319R1 1SDA071949R1 9/18 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 18 15/04/2013 18:00:48 SACE Emax E6.2H-V/f Full size • Orientable rear terminals (HR) 1SDC200664F001 Size Iu Icu (440V) Icw (1s) Type 4 Poles Code E6.2H/f 4000 5000 6300 E6.2V/f 4000 5000 6300 100 100 100 150 150 150 100 100 100 100 100 100 E6.2H/f 4000 Ekip Dip LI 1SDA071951R1 E6.2H/f 4000 Ekip Dip LSI 1SDA071952R1 E6.2H/f 4000 Ekip Dip LSIG 1SDA071953R1 E6.2H/f 4000 Ekip Touch LI 1SDA071954R1 E6.2H/f 4000 Ekip Touch LSI 1SDA071955R1 E6.2H/f 4000 Ekip Touch LSIG 1SDA071956R1 E6.2H/f 4000 Ekip Hi-Touch LSI 1SDA071958R1 E6.2H/f 4000 Ekip Hi-Touch LSIG 1SDA071959R1 E6.2H/f 5000 Ekip Dip LI 1SDA071981R1 E6.2H/f 5000 Ekip Dip LSI 1SDA071982R1 E6.2H/f 5000 Ekip Dip LSIG 1SDA071983R1 E6.2H/f 5000 Ekip Touch LI 1SDA071984R1 E6.2H/f 5000 Ekip Touch LSI 1SDA071985R1 E6.2H/f 5000 Ekip Touch LSIG 1SDA071986R1 E6.2H/f 5000 Ekip Hi-Touch LSI 1SDA071988R1 E6.2H/f 5000 Ekip Hi-Touch LSIG 1SDA071989R1 E6.2H/f 6300 Ekip Dip LI 1SDA072011R1 E6.2H/f 6300 Ekip Dip LSI 1SDA072012R1 E6.2H/f 6300 Ekip Dip LSIG 1SDA072013R1 E6.2H/f 6300 Ekip Touch LI 1SDA072014R1 E6.2H/f 6300 Ekip Touch LSI 1SDA072015R1 E6.2H/f 6300 Ekip Touch LSIG 1SDA072016R1 E6.2H/f 6300 Ekip Hi-Touch LSI 1SDA072018R1 E6.2H/f 6300 Ekip Hi-Touch LSIG 1SDA072019R1 E6.2V/f 4000 Ekip Dip LI 1SDA071961R1 E6.2V/f 4000 Ekip Dip LSI 1SDA071962R1 E6.2V/f 4000 Ekip Dip LSIG 1SDA071963R1 E6.2V/f 4000 Ekip Touch LI 1SDA071964R1 E6.2V/f 4000 Ekip Touch LSI 1SDA071965R1 E6.2V/f 4000 Ekip Touch LSIG 1SDA071966R1 E6.2V/f 4000 Ekip Hi-Touch LSI 1SDA071968R1 E6.2V/f 4000 Ekip Hi-Touch LSIG 1SDA071969R1 E6.2V/f 5000 Ekip Dip LI 1SDA071991R1 E6.2V/f 5000 Ekip Dip LSI 1SDA071992R1 E6.2V/f 5000 Ekip Dip LSIG 1SDA071993R1 E6.2V/f 5000 Ekip Touch LI 1SDA071994R1 E6.2V/f 5000 Ekip Touch LSI 1SDA071995R1 E6.2V/f 5000 Ekip Touch LSIG 1SDA071996R1 E6.2V/f 5000 Ekip Hi-Touch LSI 1SDA071998R1 E6.2V/f 5000 Ekip Hi-Touch LSIG 1SDA071999R1 E6.2V/f 6300 Ekip Dip LI 1SDA072021R1 E6.2V/f 6300 Ekip Dip LSI 1SDA072022R1 E6.2V/f 6300 Ekip Dip LSIG 1SDA072023R1 E6.2V/f 6300 Ekip Touch LI 1SDA072024R1 E6.2V/f 6300 Ekip Touch LSI 1SDA072025R1 E6.2V/f 6300 Ekip Touch LSIG 1SDA072026R1 E6.2V/f 6300 Ekip Hi-Touch LSI 1SDA072028R1 E6.2V/f 6300 Ekip Hi-Touch LSIG 1SDA072029R1 9 ABB Catalogue | 1SDC200023D0201 | 9/19 Emax2_cap09.indd 19 15/04/2013 18:00:48 Automatic circuit-breakers Fixed version for power distribution SACE Emax E6.2X/f Full size • Orientable rear terminals (HR) 1SDC200664F001 Size Iu Icu (440V) Icw (1s) Type 4 Poles Code E6.2X/f 4000 5000 6300 9 200 200 200 120 120 120 E6.2X/f 4000 Ekip Dip LI 1SDA071971R1 E6.2X/f 4000 Ekip Dip LSI 1SDA071972R1 E6.2X/f 4000 Ekip Dip LSIG 1SDA071973R1 E6.2X/f 4000 Ekip Touch LI 1SDA071974R1 E6.2X/f 4000 Ekip Touch LSI 1SDA071975R1 E6.2X/f 4000 Ekip Touch LSIG 1SDA071976R1 E6.2X/f 4000 Ekip Hi-Touch LSI 1SDA071978R1 E6.2X/f 4000 Ekip Hi-Touch LSIG 1SDA071979R1 E6.2X/f 5000 Ekip Dip LI 1SDA072001R1 E6.2X/f 5000 Ekip Dip LSI 1SDA072002R1 E6.2X/f 5000 Ekip Dip LSIG 1SDA072003R1 E6.2X/f 5000 Ekip Touch LI 1SDA072004R1 E6.2X/f 5000 Ekip Touch LSI 1SDA072005R1 E6.2X/f 5000 Ekip Touch LSIG 1SDA072006R1 E6.2X/f 5000 Ekip Hi-Touch LSI 1SDA072008R1 E6.2X/f 5000 Ekip Hi-Touch LSIG 1SDA072009R1 E6.2X/f 6300 Ekip Dip LI 1SDA072031R1 E6.2X/f 6300 Ekip Dip LSI 1SDA072032R1 E6.2X/f 6300 Ekip Dip LSIG 1SDA072033R1 E6.2X/f 6300 Ekip Touch LI 1SDA072034R1 E6.2X/f 6300 Ekip Touch LSI 1SDA072035R1 E6.2X/f 6300 Ekip Touch LSIG 1SDA072036R1 E6.2X/f 6300 Ekip Hi-Touch LSI 1SDA072038R1 E6.2X/f 6300 Ekip Hi-Touch LSIG 1SDA072039R1 9/20 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 20 15/04/2013 18:00:49 Automatic circuit-breakers Withdrawable version for power distribution 1SDC200665F001 SACE Emax E1.2B • Mobile part of withdrawable circuit-breaker (MP) Size E1.2B Iu 630 800 1000 1250 1600 Icu Icw (440 V) (1s) Type 42 42 42 42 42 42 42 42 42 42 3 Poles 4 Poles Code Code E1.2B 630 Ekip Dip LI 1SDA072051R1 1SDA072681R1 E1.2B 630 Ekip Dip LSI 1SDA072052R1 1SDA072682R1 E1.2B 630 Ekip Dip LSIG 1SDA072053R1 1SDA072683R1 E1.2B 630 Ekip Touch LI 1SDA072054R1 1SDA072684R1 E1.2B 630 Ekip Touch LSI 1SDA072055R1 1SDA072685R1 E1.2B 630 Ekip Touch LSIG 1SDA072056R1 1SDA072686R1 E1.2B 630 Ekip Hi-Touch LSI 1SDA072058R1 1SDA072688R1 E1.2B 630 Ekip Hi-Touch LSIG 1SDA072059R1 1SDA072689R1 E1.2B 800 Ekip Dip LI 1SDA072091R1 1SDA072721R1 E1.2B 800 Ekip Dip LSI 1SDA072092R1 1SDA072722R1 E1.2B 800 Ekip Dip LSIG 1SDA072093R1 1SDA072723R1 E1.2B 800 Ekip Touch LI 1SDA072094R1 1SDA072724R1 E1.2B 800 Ekip Touch LSI 1SDA072095R1 1SDA072725R1 E1.2B 800 Ekip Touch LSIG 1SDA072096R1 1SDA072726R1 E1.2B 800 Ekip Hi-Touch LSI 1SDA072098R1 1SDA072728R1 E1.2B 800 Ekip Hi-Touch LSIG 1SDA072099R1 1SDA072729R1 E1.2B 1000 Ekip Dip LI 1SDA072131R1 1SDA072761R1 E1.2B 1000 Ekip Dip LSI 1SDA072132R1 1SDA072762R1 E1.2B 1000 Ekip Dip LSIG 1SDA072133R1 1SDA072763R1 E1.2B 1000 Ekip Touch LI 1SDA072134R1 1SDA072764R1 E1.2B 1000 Ekip Touch LSI 1SDA072135R1 1SDA072765R1 E1.2B 1000 Ekip Touch LSIG 1SDA072136R1 1SDA072766R1 E1.2B 1000 Ekip Hi-Touch LSI 1SDA072138R1 1SDA072768R1 E1.2B 1000 Ekip Hi-Touch LSIG 1SDA072139R1 1SDA072769R1 E1.2B 1250 Ekip Dip LI 1SDA072171R1 1SDA072801R1 E1.2B 1250 Ekip Dip LSI 1SDA072172R1 1SDA072802R1 E1.2B 1250 Ekip Dip LSIG 1SDA072173R1 1SDA072803R1 E1.2B 1250 Ekip Touch LI 1SDA072174R1 1SDA072804R1 E1.2B 1250 Ekip Touch LSI 1SDA072175R1 1SDA072805R1 E1.2B 1250 Ekip Touch LSIG 1SDA072176R1 1SDA072806R1 E1.2B 1250 Ekip Hi-Touch LSI 1SDA072178R1 1SDA072808R1 E1.2B 1250 Ekip Hi-Touch LSIG 1SDA072179R1 1SDA072809R1 E1.2B 1600 Ekip Dip LI 1SDA072211R1 1SDA072841R1 E1.2B 1600 Ekip Dip LSI 1SDA072212R1 1SDA072842R1 E1.2B 1600 Ekip Dip LSIG 1SDA072213R1 1SDA072843R1 E1.2B 1600 Ekip Touch LI 1SDA072214R1 1SDA072844R1 E1.2B 1600 Ekip Touch LSI 1SDA072215R1 1SDA072845R1 E1.2B 1600 Ekip Touch LSIG 1SDA072216R1 1SDA072846R1 E1.2B 1600 Ekip Hi-Touch LSI 1SDA072218R1 1SDA072848R1 E1.2B 1600 Ekip Hi-Touch LSIG 1SDA072219R1 1SDA072849R1 9 ABB Catalogue | 1SDC200023D0201 | 9/21 Emax2_cap09.indd 21 15/04/2013 18:00:50 Automatic circuit-breakers Withdrawable version for power distribution 1SDC200665F001 SACE Emax E1.2C • Mobile part of withdrawable circuit-breaker (MP) Size E1.2C Iu 630 800 1000 Icu Icw (440 V) (1s) Type 50 50 50 42 42 42 9 1250 1600 50 50 42 42 3 Poles 4 Poles Code Code E1.2C 630 Ekip Dip LI 1SDA072061R1 1SDA072691R1 E1.2C 630 Ekip Dip LSI 1SDA072062R1 1SDA072692R1 E1.2C 630 Ekip Dip LSIG 1SDA072063R1 1SDA072693R1 E1.2C 630 Ekip Touch LI 1SDA072064R1 1SDA072694R1 E1.2C 630 Ekip Touch LSI 1SDA072065R1 1SDA072695R1 E1.2C 630 Ekip Touch LSIG 1SDA072066R1 1SDA072696R1 E1.2C 630 Ekip Hi-Touch LSI 1SDA072068R1 1SDA072698R1 E1.2C 630 Ekip Hi-Touch LSIG 1SDA072069R1 1SDA072699R1 E1.2C 800 Ekip Dip LI 1SDA072101R1 1SDA072731R1 E1.2C 800 Ekip Dip LSI 1SDA072102R1 1SDA072732R1 E1.2C 800 Ekip Dip LSIG 1SDA072103R1 1SDA072733R1 E1.2C 800 Ekip Touch LI 1SDA072104R1 1SDA072734R1 E1.2C 800 Ekip Touch LSI 1SDA072105R1 1SDA072735R1 E1.2C 800 Ekip Touch LSIG 1SDA072106R1 1SDA072736R1 E1.2C 800 Ekip Hi-Touch LSI 1SDA072108R1 1SDA072738R1 E1.2C 800 Ekip Hi-Touch LSIG 1SDA072109R1 1SDA072739R1 E1.2C 1000 Ekip Dip LI 1SDA072141R1 1SDA072771R1 E1.2C 1000 Ekip Dip LSI 1SDA072142R1 1SDA072772R1 E1.2C 1000 Ekip Dip LSIG 1SDA072143R1 1SDA072773R1 E1.2C 1000 Ekip Touch LI 1SDA072144R1 1SDA072774R1 E1.2C 1000 Ekip Touch LSI 1SDA072145R1 1SDA072775R1 E1.2C 1000 Ekip Touch LSIG 1SDA072146R1 1SDA072776R1 E1.2C 1000 Ekip Hi-Touch LSI 1SDA072148R1 1SDA072778R1 E1.2C 1000 Ekip Hi-Touch LSIG 1SDA072149R1 1SDA072779R1 E1.2C 1250 Ekip Dip LI 1SDA072181R1 1SDA072811R1 E1.2C 1250 Ekip Dip LSI 1SDA072182R1 1SDA072812R1 E1.2C 1250 Ekip Dip LSIG 1SDA072183R1 1SDA072813R1 E1.2C 1250 Ekip Touch LI 1SDA072184R1 1SDA072814R1 E1.2C 1250 Ekip Touch LSI 1SDA072185R1 1SDA072815R1 E1.2C 1250 Ekip Touch LSIG 1SDA072186R1 1SDA072816R1 E1.2C 1250 Ekip Hi-Touch LSI 1SDA072188R1 1SDA072818R1 E1.2C 1250 Ekip Hi-Touch LSIG 1SDA072189R1 1SDA072819R1 E1.2C 1600 Ekip Dip LI 1SDA072221R1 1SDA072851R1 E1.2C 1600 Ekip Dip LSI 1SDA072222R1 1SDA072852R1 E1.2C 1600 Ekip Dip LSIG 1SDA072223R1 1SDA072853R1 E1.2C 1600 Ekip Touch LI 1SDA072224R1 1SDA072854R1 E1.2C 1600 Ekip Touch LSI 1SDA072225R1 1SDA072855R1 E1.2C 1600 Ekip Touch LSIG 1SDA072226R1 1SDA072856R1 E1.2C 1600 Ekip Hi-Touch LSI 1SDA072228R1 1SDA072858R1 E1.2C 1600 Ekip Hi-Touch LSIG 1SDA072229R1 1SDA072859R1 9/22 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 22 15/04/2013 18:00:51 1SDC200665F001 SACE Emax E1.2N • Mobile part of withdrawable circuit-breaker (MP) Size E1.2N Iu 250 630 800 1000 1250 1600 Icu Icw (440 V) (1s) Type 66 66 66 66 66 66 50 50 50 50 50 50 3 Poles 4 Poles Code Code E1.2N 250 Ekip Dip LI 1SDA072041R1 1SDA072671R1 E1.2N 250 Ekip Dip LSI 1SDA072042R1 1SDA072672R1 E1.2N 250 Ekip Dip LSIG 1SDA072043R1 1SDA072673R1 E1.2N 250 Ekip Touch LI 1SDA072044R1 1SDA072674R1 E1.2N 250 Ekip Touch LSI 1SDA072045R1 1SDA072675R1 E1.2N 250 Ekip Touch LSIG 1SDA072046R1 1SDA072676R1 E1.2N 250 Ekip Hi-Touch LSI 1SDA072048R1 1SDA072678R1 E1.2N 250 Ekip Hi-Touch LSIG 1SDA072049R1 1SDA072679R1 E1.2N 630 Ekip Dip LI 1SDA072071R1 1SDA072701R1 E1.2N 630 Ekip Dip LSI 1SDA072072R1 1SDA072702R1 E1.2N 630 Ekip Dip LSIG 1SDA072073R1 1SDA072703R1 E1.2N 630 Ekip Touch LI 1SDA072074R1 1SDA072704R1 E1.2N 630 Ekip Touch LSI 1SDA072075R1 1SDA072705R1 E1.2N 630 Ekip Touch LSIG 1SDA072076R1 1SDA072706R1 E1.2N 630 Ekip Hi-Touch LSI 1SDA072078R1 1SDA072708R1 E1.2N 630 Ekip Hi-Touch LSIG 1SDA072079R1 1SDA072709R1 E1.2N 800 Ekip Dip LI 1SDA072111R1 1SDA072741R1 E1.2N 800 Ekip Dip LSI 1SDA072112R1 1SDA072742R1 E1.2N 800 Ekip Dip LSIG 1SDA072113R1 1SDA072743R1 E1.2N 800 Ekip Touch LI 1SDA072114R1 1SDA072744R1 E1.2N 800 Ekip Touch LSI 1SDA072115R1 1SDA072745R1 E1.2N 800 Ekip Touch LSIG 1SDA072116R1 1SDA072746R1 E1.2N 800 Ekip Hi-Touch LSI 1SDA072118R1 1SDA072748R1 E1.2N 800 Ekip Hi-Touch LSIG 1SDA072119R1 1SDA072749R1 E1.2N 1000 Ekip Dip LI 1SDA072151R1 1SDA072781R1 E1.2N 1000 Ekip Dip LSI 1SDA072152R1 1SDA072782R1 E1.2N 1000 Ekip Dip LSIG 1SDA072153R1 1SDA072783R1 E1.2N 1000 Ekip Touch LI 1SDA072154R1 1SDA072784R1 E1.2N 1000 Ekip Touch LSI 1SDA072155R1 1SDA072785R1 E1.2N 1000 Ekip Touch LSIG 1SDA072156R1 1SDA072786R1 E1.2N 1000 Ekip Hi-Touch LSI 1SDA072158R1 1SDA072788R1 E1.2N 1000 Ekip Hi-Touch LSIG 1SDA072159R1 1SDA072789R1 E1.2N 1250 Ekip Dip LI 1SDA072191R1 1SDA072821R1 E1.2N 1250 Ekip Dip LSI 1SDA072192R1 1SDA072822R1 E1.2N 1250 Ekip Dip LSIG 1SDA072193R1 1SDA072823R1 E1.2N 1250 Ekip Touch LI 1SDA072194R1 1SDA072824R1 E1.2N 1250 Ekip Touch LSI 1SDA072195R1 1SDA072825R1 E1.2N 1250 Ekip Touch LSIG 1SDA072196R1 1SDA072826R1 E1.2N 1250 Ekip Hi-Touch LSI 1SDA072198R1 1SDA072828R1 E1.2N 1250 Ekip Hi-Touch LSIG 1SDA072199R1 1SDA072829R1 E1.2N 1600 Ekip Dip LI 1SDA072231R1 1SDA072861R1 E1.2N 1600 Ekip Dip LSI 1SDA072232R1 1SDA072862R1 E1.2N 1600 Ekip Dip LSIG 1SDA072233R1 1SDA072863R1 E1.2N 1600 Ekip Touch LI 1SDA072234R1 1SDA072864R1 E1.2N 1600 Ekip Touch LSI 1SDA072235R1 1SDA072865R1 E1.2N 1600 Ekip Touch LSIG 1SDA072236R1 1SDA072866R1 E1.2N 1600 Ekip Hi-Touch LSI 1SDA072238R1 1SDA072868R1 E1.2N 1600 Ekip Hi-Touch LSIG 1SDA072239R1 1SDA072869R1 9 ABB Catalogue | 1SDC200023D0201 | 9/23 Emax2_cap09.indd 23 15/04/2013 18:00:52 Automatic circuit-breakers Withdrawable version for power distribution 1SDC200665F001 SACE Emax E1.2L-B • Mobile part of withdrawable circuit-breaker (MP) Size E1.2L Iu 630 800 1000 Icu Icw (440 V) (1s) Type 130 130 130 15 15 15 9 1250 E2.2B 1600 2000 130 42 42 15 42 42 3 Poles 4 Poles Code Code E1.2L 630 Ekip Dip LI 1SDA072081R1 1SDA072711R1 E1.2L 630 Ekip Dip LSI 1SDA072082R1 1SDA072712R1 E1.2L 630 Ekip Dip LSIG 1SDA072083R1 1SDA072713R1 E1.2L 630 Ekip Touch LI 1SDA072084R1 1SDA072714R1 E1.2L 630 Ekip Touch LSI 1SDA072085R1 1SDA072715R1 E1.2L 630 Ekip Touch LSIG 1SDA072086R1 1SDA072716R1 E1.2L 630 Ekip Hi-Touch LSI 1SDA072088R1 1SDA072718R1 E1.2L 630 Ekip Hi-Touch LSIG 1SDA072089R1 1SDA072719R1 E1.2L 800 Ekip Dip LI 1SDA072121R1 1SDA072751R1 E1.2L 800 Ekip Dip LSI 1SDA072122R1 1SDA072752R1 E1.2L 800 Ekip Dip LSIG 1SDA072123R1 1SDA072753R1 E1.2L 800 Ekip Touch LI 1SDA072124R1 1SDA072754R1 E1.2L 800 Ekip Touch LSI 1SDA072125R1 1SDA072755R1 E1.2L 800 Ekip Touch LSIG 1SDA072126R1 1SDA072756R1 E1.2L 800 Ekip Hi-Touch LSI 1SDA072128R1 1SDA072758R1 E1.2L 800 Ekip Hi-Touch LSIG 1SDA072129R1 1SDA072759R1 E1.2L 1000 Ekip Dip LI 1SDA072161R1 1SDA072791R1 E1.2L 1000 Ekip Dip LSI 1SDA072162R1 1SDA072792R1 E1.2L 1000 Ekip Dip LSIG 1SDA072163R1 1SDA072793R1 E1.2L 1000 Ekip Touch LI 1SDA072164R1 1SDA072794R1 E1.2L 1000 Ekip Touch LSI 1SDA072165R1 1SDA072795R1 E1.2L 1000 Ekip Touch LSIG 1SDA072166R1 1SDA072796R1 E1.2L 1000 Ekip Hi-Touch LSI 1SDA072168R1 1SDA072798R1 E1.2L 1000 Ekip Hi-Touch LSIG 1SDA072169R1 1SDA072799R1 E1.2L 1250 Ekip Dip LI 1SDA072201R1 1SDA072831R1 E1.2L 1250 Ekip Dip LSI 1SDA072202R1 1SDA072832R1 E1.2L 1250 Ekip Dip LSIG 1SDA072203R1 1SDA072833R1 E1.2L 1250 Ekip Touch LI 1SDA072204R1 1SDA072834R1 E1.2L 1250 Ekip Touch LSI 1SDA072205R1 1SDA072835R1 E1.2L 1250 Ekip Touch LSIG 1SDA072206R1 1SDA072836R1 E1.2L 1250 Ekip Hi-Touch LSI 1SDA072208R1 1SDA072838R1 E1.2L 1250 Ekip Hi-Touch LSIG 1SDA072209R1 1SDA072839R1 E2.2B 1600 Ekip Dip LI 1SDA072331R1 1SDA072961R1 E2.2B 1600 Ekip Dip LSI 1SDA072332R1 1SDA072962R1 E2.2B 1600 Ekip Dip LSIG 1SDA072333R1 1SDA072963R1 E2.2B 1600 Ekip Touch LI 1SDA072334R1 1SDA072964R1 E2.2B 1600 Ekip Touch LSI 1SDA072335R1 1SDA072965R1 E2.2B 1600 Ekip Touch LSIG 1SDA072336R1 1SDA072966R1 E2.2B 1600 Ekip Hi-Touch LSI 1SDA072338R1 1SDA072968R1 E2.2B 1600 Ekip Hi-Touch LSIG 1SDA072339R1 1SDA072969R1 E2.2B 2000 Ekip Dip LI 1SDA072371R1 1SDA073001R1 E2.2B 2000 Ekip Dip LSI 1SDA072372R1 1SDA073002R1 E2.2B 2000 Ekip Dip LSIG 1SDA072373R1 1SDA073003R1 E2.2B 2000 Ekip Touch LI 1SDA072374R1 1SDA073004R1 E2.2B 2000 Ekip Touch LSI 1SDA072375R1 1SDA073005R1 E2.2B 2000 Ekip Touch LSIG 1SDA072376R1 1SDA073006R1 E2.2B 2000 Ekip Hi-Touch LSI 1SDA072378R1 1SDA073008R1 E2.2B 2000 Ekip Hi-Touch LSIG 1SDA072379R1 1SDA073009R1 9/24 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 24 15/04/2013 18:00:53 SACE Emax E2.2N • Mobile part of withdrawable circuit-breaker (MP) 1SDC200666F001 Size E2.2N Iu 800 1000 1250 1600 2000 2500 Icu Icw (440 V) (1s) Type 66 66 66 66 66 66 66 66 66 66 66 66 3 Poles 4 Poles Code Code E2.2N 800 Ekip Dip LI 1SDA072241R1 1SDA072871R1 E2.2N 800 Ekip Dip LSI 1SDA072242R1 1SDA072872R1 E2.2N 800 Ekip Dip LSIG 1SDA072243R1 1SDA072873R1 E2.2N 800 Ekip Touch LI 1SDA072244R1 1SDA072874R1 E2.2N 800 Ekip Touch LSI 1SDA072245R1 1SDA072875R1 E2.2N 800 Ekip Touch LSIG 1SDA072246R1 1SDA072876R1 E2.2N 800 Ekip Hi-Touch LSI 1SDA072248R1 1SDA072878R1 E2.2N 800 Ekip Hi-Touch LSIG 1SDA072249R1 1SDA072879R1 E2.2N 1000 Ekip Dip LI 1SDA072271R1 1SDA072901R1 E2.2N 1000 Ekip Dip LSI 1SDA072272R1 1SDA072902R1 E2.2N 1000 Ekip Dip LSIG 1SDA072273R1 1SDA072903R1 E2.2N 1000 Ekip Touch LI 1SDA072274R1 1SDA072904R1 E2.2N 1000 Ekip Touch LSI 1SDA072275R1 1SDA072905R1 E2.2N 1000 Ekip Touch LSIG 1SDA072276R1 1SDA072906R1 E2.2N 1000 Ekip Hi-Touch LSI 1SDA072278R1 1SDA072908R1 E2.2N 1000 Ekip Hi-Touch LSIG 1SDA072279R1 1SDA072909R1 E2.2N 1250 Ekip Dip LI 1SDA072301R1 1SDA072931R1 E2.2N 1250 Ekip Dip LSI 1SDA072302R1 1SDA072932R1 E2.2N 1250 Ekip Dip LSIG 1SDA072303R1 1SDA072933R1 E2.2N 1250 Ekip Touch LI 1SDA072304R1 1SDA072934R1 E2.2N 1250 Ekip Touch LSI 1SDA072305R1 1SDA072935R1 E2.2N 1250 Ekip Touch LSIG 1SDA072306R1 1SDA072936R1 E2.2N 1250 Ekip Hi-Touch LSI 1SDA072308R1 1SDA072938R1 E2.2N 1250 Ekip Hi-Touch LSIG 1SDA072309R1 1SDA072939R1 E2.2N 1600 Ekip Dip LI 1SDA072341R1 1SDA072971R1 E2.2N 1600 Ekip Dip LSI 1SDA072342R1 1SDA072972R1 E2.2N 1600 Ekip Dip LSIG 1SDA072343R1 1SDA072973R1 E2.2N 1600 Ekip Touch LI 1SDA072344R1 1SDA072974R1 E2.2N 1600 Ekip Touch LSI 1SDA072345R1 1SDA072975R1 E2.2N 1600 Ekip Touch LSIG 1SDA072346R1 1SDA072976R1 E2.2N 1600 Ekip Hi-Touch LSI 1SDA072348R1 1SDA072978R1 E2.2N 1600 Ekip Hi-Touch LSIG 1SDA072349R1 1SDA072979R1 E2.2N 2000 Ekip Dip LI 1SDA072381R1 1SDA073011R1 E2.2N 2000 Ekip Dip LSI 1SDA072382R1 1SDA073012R1 E2.2N 2000 Ekip Dip LSIG 1SDA072383R1 1SDA073013R1 E2.2N 2000 Ekip Touch LI 1SDA072384R1 1SDA073014R1 E2.2N 2000 Ekip Touch LSI 1SDA072385R1 1SDA073015R1 E2.2N 2000 Ekip Touch LSIG 1SDA072386R1 1SDA073016R1 E2.2N 2000 Ekip Hi-Touch LSI 1SDA072388R1 1SDA073018R1 E2.2N 2000 Ekip Hi-Touch LSIG 1SDA072389R1 1SDA073019R1 E2.2N 2500 Ekip Dip LI 1SDA072411R1 1SDA073041R1 E2.2N 2500 Ekip Dip LSI 1SDA072412R1 1SDA073042R1 E2.2N 2500 Ekip Dip LSIG 1SDA072413R1 1SDA073043R1 E2.2N 2500 Ekip Touch LI 1SDA072414R1 1SDA073044R1 E2.2N 2500 Ekip Touch LSI 1SDA072415R1 1SDA073045R1 E2.2N 2500 Ekip Touch LSIG 1SDA072416R1 1SDA073046R1 E2.2N 2500 Ekip Hi-Touch LSI 1SDA072418R1 1SDA073048R1 E2.2N 2500 Ekip Hi-Touch LSIG 1SDA072419R1 1SDA073049R1 9 ABB Catalogue | 1SDC200023D0201 | 9/25 Emax2_cap09.indd 25 15/04/2013 18:00:54 Automatic circuit-breakers Withdrawable version for power distribution SACE Emax E2.2S • Mobile part of withdrawable circuit-breaker (MP) 1SDC200666F001 Size E2.2S Iu 250 800 1000 Icu Icw (440 V) (1s) Type 85 85 85 66 66 66 9 1250 85 66 3 Poles 4 Poles Code Code E2.2S 250 Ekip Dip LI 1SDA073648R1 1SDA073658R1 E2.2S 250 Ekip Dip LSI 1SDA073649R1 1SDA073659R1 E2.2S 250 Ekip Dip LSIG 1SDA073650R1 1SDA073660R1 E2.2S 250 Ekip Touch LI 1SDA073651R1 1SDA073661R1 E2.2S 250 Ekip Touch LSI 1SDA073652R1 1SDA073662R1 E2.2S 250 Ekip Touch LSIG 1SDA073653R1 1SDA073663R1 E2.2S 250 Ekip Hi-Touch LSI 1SDA073655R1 1SDA073665R1 E2.2S 250 Ekip Hi-Touch LSIG 1SDA073656R1 1SDA073666R1 E2.2S 800 Ekip Dip LI 1SDA072251R1 1SDA072881R1 E2.2S 800 Ekip Dip LSI 1SDA072252R1 1SDA072882R1 E2.2S 800 Ekip Dip LSIG 1SDA072253R1 1SDA072883R1 E2.2S 800 Ekip Touch LI 1SDA072254R1 1SDA072884R1 E2.2S 800 Ekip Touch LSI 1SDA072255R1 1SDA072885R1 E2.2S 800 Ekip Touch LSIG 1SDA072256R1 1SDA072886R1 E2.2S 800 Ekip Hi-Touch LSI 1SDA072258R1 1SDA072888R1 E2.2S 800 Ekip Hi-Touch LSIG 1SDA072259R1 1SDA072889R1 E2.2S 1000 Ekip Dip LI 1SDA072281R1 1SDA072911R1 E2.2S 1000 Ekip Dip LSI 1SDA072282R1 1SDA072912R1 E2.2S 1000 Ekip Dip LSIG 1SDA072283R1 1SDA072913R1 E2.2S 1000 Ekip Touch LI 1SDA072284R1 1SDA072914R1 E2.2S 1000 Ekip Touch LSI 1SDA072285R1 1SDA072915R1 E2.2S 1000 Ekip Touch LSIG 1SDA072286R1 1SDA072916R1 E2.2S 1000 Ekip Hi-Touch LSI 1SDA072288R1 1SDA072918R1 E2.2S 1000 Ekip Hi-Touch LSIG 1SDA072289R1 1SDA072919R1 E2.2S 1250 Ekip Dip LI 1SDA072311R1 1SDA072941R1 E2.2S 1250 Ekip Dip LSI 1SDA072312R1 1SDA072942R1 E2.2S 1250 Ekip Dip LSIG 1SDA072313R1 1SDA072943R1 E2.2S 1250 Ekip Touch LI 1SDA072314R1 1SDA072944R1 E2.2S 1250 Ekip Touch LSI 1SDA072315R1 1SDA072945R1 E2.2S 1250 Ekip Touch LSIG 1SDA072316R1 1SDA072946R1 E2.2S 1250 Ekip Hi-Touch LSI 1SDA072318R1 1SDA072948R1 E2.2S 1250 Ekip Hi-Touch LSIG 1SDA072319R1 1SDA072949R1 9/26 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 26 15/04/2013 18:00:56 SACE Emax E2.2S • Mobile part of withdrawable circuit-breaker (MP) 1SDC200666F001 Size E2.2S Iu 1600 2000 2500 Icu Icw (440 V) (1s) Type 85 85 85 66 66 66 3 Poles 4 Poles Code Code E2.2S 1600 Ekip Dip LI 1SDA072351R1 1SDA072981R1 E2.2S 1600 Ekip Dip LSI 1SDA072352R1 1SDA072982R1 E2.2S 1600 Ekip Dip LSIG 1SDA072353R1 1SDA072983R1 E2.2S 1600 Ekip Touch LI 1SDA072354R1 1SDA072984R1 E2.2S 1600 Ekip Touch LSI 1SDA072355R1 1SDA072985R1 E2.2S 1600 Ekip Touch LSIG 1SDA072356R1 1SDA072986R1 E2.2S 1600 Ekip Hi-Touch LSI 1SDA072358R1 1SDA072988R1 E2.2S 1600 Ekip Hi-Touch LSIG 1SDA072359R1 1SDA072989R1 E2.2S 2000 Ekip Dip LI 1SDA072391R1 1SDA073021R1 E2.2S 2000 Ekip Dip LSI 1SDA072392R1 1SDA073022R1 E2.2S 2000 Ekip Dip LSIG 1SDA072393R1 1SDA073023R1 E2.2S 2000 Ekip Touch LI 1SDA072394R1 1SDA073024R1 E2.2S 2000 Ekip Touch LSI 1SDA072395R1 1SDA073025R1 E2.2S 2000 Ekip Touch LSIG 1SDA072396R1 1SDA073026R1 E2.2S 2000 Ekip Hi-Touch LSI 1SDA072398R1 1SDA073028R1 E2.2S 2000 Ekip Hi-Touch LSIG 1SDA072399R1 1SDA073029R1 E2.2S 2500 Ekip Dip LI 1SDA072421R1 1SDA073051R1 E2.2S 2500 Ekip Dip LSI 1SDA072422R1 1SDA073052R1 E2.2S 2500 Ekip Dip LSIG 1SDA072423R1 1SDA073053R1 E2.2S 2500 Ekip Touch LI 1SDA072424R1 1SDA073054R1 E2.2S 2500 Ekip Touch LSI 1SDA072425R1 1SDA073055R1 E2.2S 2500 Ekip Touch LSIG 1SDA072426R1 1SDA073056R1 E2.2S 2500 Ekip Hi-Touch LSI 1SDA072428R1 1SDA073058R1 E2.2S 2500 Ekip Hi-Touch LSIG 1SDA072429R1 1SDA073059R1 9 ABB Catalogue | 1SDC200023D0201 | 9/27 Emax2_cap09.indd 27 15/04/2013 18:00:57 Automatic circuit-breakers Withdrawable version for power distribution SACE Emax E2.2H • Mobile part of withdrawable circuit-breaker (MP) 1SDC200666F001 Size E2.2H Iu 800 1000 1250 Icu Icw (440 V) (1s) Type 100 100 100 85 85 85 9 1600 2000 2500 100 100 100 85 85 85 3 Poles 4 Poles Code Code E2.2H 800 Ekip Dip LI 1SDA072261R1 1SDA072891R1 E2.2H 800 Ekip Dip LSI 1SDA072262R1 1SDA072892R1 E2.2H 800 Ekip Dip LSIG 1SDA072263R1 1SDA072893R1 E2.2H 800 Ekip Touch LI 1SDA072264R1 1SDA072894R1 E2.2H 800 Ekip Touch LSI 1SDA072265R1 1SDA072895R1 E2.2H 800 Ekip Touch LSIG 1SDA072266R1 1SDA072896R1 E2.2H 800 Ekip Hi-Touch LSI 1SDA072268R1 1SDA072898R1 E2.2H 800 Ekip Hi-Touch LSIG 1SDA072269R1 1SDA072899R1 E2.2H 1000 Ekip Dip LI 1SDA072291R1 1SDA072921R1 E2.2H 1000 Ekip Dip LSI 1SDA072292R1 1SDA072922R1 E2.2H 1000 Ekip Dip LSIG 1SDA072293R1 1SDA072923R1 E2.2H 1000 Ekip Touch LI 1SDA072294R1 1SDA072924R1 E2.2H 1000 Ekip Touch LSI 1SDA072295R1 1SDA072925R1 E2.2H 1000 Ekip Touch LSIG 1SDA072296R1 1SDA072926R1 E2.2H 1000 Ekip Hi-Touch LSI 1SDA072298R1 1SDA072928R1 E2.2H 1000 Ekip Hi-Touch LSIG 1SDA072299R1 1SDA072929R1 E2.2H 1250 Ekip Dip LI 1SDA072321R1 1SDA072951R1 E2.2H 1250 Ekip Dip LSI 1SDA072322R1 1SDA072952R1 E2.2H 1250 Ekip Dip LSIG 1SDA072323R1 1SDA072953R1 E2.2H 1250 Ekip Touch LI 1SDA072324R1 1SDA072954R1 E2.2H 1250 Ekip Touch LSI 1SDA072325R1 1SDA072955R1 E2.2H 1250 Ekip Touch LSIG 1SDA072326R1 1SDA072956R1 E2.2H 1250 Ekip Hi-Touch LSI 1SDA072328R1 1SDA072958R1 E2.2H 1250 Ekip Hi-Touch LSIG 1SDA072329R1 1SDA072959R1 E2.2H 1600 Ekip Dip LI 1SDA072361R1 1SDA072991R1 E2.2H 1600 Ekip Dip LSI 1SDA072362R1 1SDA072992R1 E2.2H 1600 Ekip Dip LSIG 1SDA072363R1 1SDA072993R1 E2.2H 1600 Ekip Touch LI 1SDA072364R1 1SDA072994R1 E2.2H 1600 Ekip Touch LSI 1SDA072365R1 1SDA072995R1 E2.2H 1600 Ekip Touch LSIG 1SDA072366R1 1SDA072996R1 E2.2H 1600 Ekip Hi-Touch LSI 1SDA072368R1 1SDA072998R1 E2.2H 1600 Ekip Hi-Touch LSIG 1SDA072369R1 1SDA072999R1 E2.2H 2000 Ekip Dip LI 1SDA072401R1 1SDA073031R1 E2.2H 2000 Ekip Dip LSI 1SDA072402R1 1SDA073032R1 E2.2H 2000 Ekip Dip LSIG 1SDA072403R1 1SDA073033R1 E2.2H 2000 Ekip Touch LI 1SDA072404R1 1SDA073034R1 E2.2H 2000 Ekip Touch LSI 1SDA072405R1 1SDA073035R1 E2.2H 2000 Ekip Touch LSIG 1SDA072406R1 1SDA073036R1 E2.2H 2000 Ekip Hi-Touch LSI 1SDA072408R1 1SDA073038R1 E2.2H 2000 Ekip Hi-Touch LSIG 1SDA072409R1 1SDA073039R1 E2.2H 2500 Ekip Dip LI 1SDA072431R1 1SDA073061R1 E2.2H 2500 Ekip Dip LSI 1SDA072432R1 1SDA073062R1 E2.2H 2500 Ekip Dip LSIG 1SDA072433R1 1SDA073063R1 E2.2H 2500 Ekip Touch LI 1SDA072434R1 1SDA073064R1 E2.2H 2500 Ekip Touch LSI 1SDA072435R1 1SDA073065R1 E2.2H 2500 Ekip Touch LSIG 1SDA072436R1 1SDA073066R1 E2.2H 2500 Ekip Hi-Touch LSI 1SDA072438R1 1SDA073068R1 E2.2H 2500 Ekip Hi-Touch LSIG 1SDA072439R1 1SDA073069R1 9/28 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 28 15/04/2013 18:00:59 SACE Emax E4.2N-S-H • Mobile part of withdrawable circuit-breaker (MP) 1SDC200667F001 Size E4.2N Iu 3200 4000 E4.2S 3200 4000 E4.2H 3200 4000 Icu Icw (440 V) (1s) Type 66 66 85 85 100 100 66 66 66 66 85 85 3 Poles 4 Poles Code Code E4.2N 3200 Ekip Dip LI 1SDA072491R1 1SDA073121R1 E4.2N 3200 Ekip Dip LSI 1SDA072492R1 1SDA073122R1 E4.2N 3200 Ekip Dip LSIG 1SDA072493R1 1SDA073123R1 E4.2N 3200 Ekip Touch LI 1SDA072494R1 1SDA073124R1 E4.2N 3200 Ekip Touch LSI 1SDA072495R1 1SDA073125R1 E4.2N 3200 Ekip Touch LSIG 1SDA072496R1 1SDA073126R1 E4.2N 3200 Ekip Hi-Touch LSI 1SDA072498R1 1SDA073128R1 E4.2N 3200 Ekip Hi-Touch LSIG 1SDA072499R1 1SDA073129R1 E4.2N 4000 Ekip Dip LI 1SDA072541R1 1SDA073171R1 E4.2N 4000 Ekip Dip LSI 1SDA072542R1 1SDA073172R1 E4.2N 4000 Ekip Dip LSIG 1SDA072543R1 1SDA073173R1 E4.2N 4000 Ekip Touch LI 1SDA072544R1 1SDA073174R1 E4.2N 4000 Ekip Touch LSI 1SDA072545R1 1SDA073175R1 E4.2N 4000 Ekip Touch LSIG 1SDA072546R1 1SDA073176R1 E4.2N 4000 Ekip Hi-Touch LSI 1SDA072548R1 1SDA073178R1 E4.2N 4000 Ekip Hi-Touch LSIG 1SDA072549R1 1SDA073179R1 E4.2S 3200 Ekip Dip LI 1SDA072501R1 1SDA073131R1 E4.2S 3200 Ekip Dip LSI 1SDA072502R1 1SDA073132R1 E4.2S 3200 Ekip Dip LSIG 1SDA072503R1 1SDA073133R1 E4.2S 3200 Ekip Touch LI 1SDA072504R1 1SDA073134R1 E4.2S 3200 Ekip Touch LSI 1SDA072505R1 1SDA073135R1 E4.2S 3200 Ekip Touch LSIG 1SDA072506R1 1SDA073136R1 E4.2S 3200 Ekip Hi-Touch LSI 1SDA072508R1 1SDA073138R1 E4.2S 3200 Ekip Hi-Touch LSIG 1SDA072509R1 1SDA073139R1 E4.2S 4000 Ekip Dip LI 1SDA072551R1 1SDA073181R1 E4.2S 4000 Ekip Dip LSI 1SDA072552R1 1SDA073182R1 E4.2S 4000 Ekip Dip LSIG 1SDA072553R1 1SDA073183R1 E4.2S 4000 Ekip Touch LI 1SDA072554R1 1SDA073184R1 E4.2S 4000 Ekip Touch LSI 1SDA072555R1 1SDA073185R1 E4.2S 4000 Ekip Touch LSIG 1SDA072556R1 1SDA073186R1 E4.2S 4000 Ekip Hi-Touch LSI 1SDA072558R1 1SDA073188R1 E4.2S 4000 Ekip Hi-Touch LSIG 1SDA072559R1 1SDA073189R1 E4.2H 3200 Ekip Dip LI 1SDA072511R1 1SDA073141R1 E4.2H 3200 Ekip Dip LSI 1SDA072512R1 1SDA073142R1 E4.2H 3200 Ekip Dip LSIG 1SDA072513R1 1SDA073143R1 E4.2H 3200 Ekip Touch LI 1SDA072514R1 1SDA073144R1 E4.2H 3200 Ekip Touch LSI 1SDA072515R1 1SDA073145R1 E4.2H 3200 Ekip Touch LSIG 1SDA072516R1 1SDA073146R1 E4.2H 3200 Ekip Hi-Touch LSI 1SDA072518R1 1SDA073148R1 E4.2H 3200 Ekip Hi-Touch LSIG 1SDA072519R1 1SDA073149R1 E4.2H 4000 Ekip Dip LI 1SDA072561R1 1SDA073191R1 E4.2H 4000 Ekip Dip LSI 1SDA072562R1 1SDA073192R1 E4.2H 4000 Ekip Dip LSIG 1SDA072563R1 1SDA073193R1 E4.2H 4000 Ekip Touch LI 1SDA072564R1 1SDA073194R1 E4.2H 4000 Ekip Touch LSI 1SDA072565R1 1SDA073195R1 E4.2H 4000 Ekip Touch LSIG 1SDA072566R1 1SDA073196R1 E4.2H 4000 Ekip Hi-Touch LSI 1SDA072568R1 1SDA073198R1 E4.2H 4000 Ekip Hi-Touch LSIG 1SDA072569R1 1SDA073199R1 9 ABB Catalogue | 1SDC200023D0201 | 9/29 Emax2_cap09.indd 29 15/04/2013 18:01:00 Automatic circuit-breakers Withdrawable version for power distribution SACE Emax E4.2V • Mobile part of withdrawable circuit-breaker (MP) 1SDC200667F001 Size E4.2V Iu 2000 2500 3200 Icu Icw (440 V) (1s) Type 150 150 150 100 100 100 9 4000 150 100 3 Poles 4 Poles Code Code E4.2V 2000 Ekip Dip LI 1SDA072451R1 1SDA073081R1 E4.2V 2000 Ekip Dip LSI 1SDA072452R1 1SDA073082R1 E4.2V 2000 Ekip Dip LSIG 1SDA072453R1 1SDA073083R1 E4.2V 2000 Ekip Touch LI 1SDA072454R1 1SDA073084R1 E4.2V 2000 Ekip Touch LSI 1SDA072455R1 1SDA073085R1 E4.2V 2000 Ekip Touch LSIG 1SDA072456R1 1SDA073086R1 E4.2V 2000 Ekip Hi-Touch LSI 1SDA072458R1 1SDA073088R1 E4.2V 2000 Ekip Hi-Touch LSIG 1SDA072459R1 1SDA073089R1 E4.2V 2500 Ekip Dip LI 1SDA072471R1 1SDA073101R1 E4.2V 2500 Ekip Dip LSI 1SDA072472R1 1SDA073102R1 E4.2V 2500 Ekip Dip LSIG 1SDA072473R1 1SDA073103R1 E4.2V 2500 Ekip Touch LI 1SDA072474R1 1SDA073104R1 E4.2V 2500 Ekip Touch LSI 1SDA072475R1 1SDA073105R1 E4.2V 2500 Ekip Touch LSIG 1SDA072476R1 1SDA073106R1 E4.2V 2500 Ekip Hi-Touch LSI 1SDA072478R1 1SDA073108R1 E4.2V 2500 Ekip Hi-Touch LSIG 1SDA072479R1 1SDA073109R1 E4.2V 3200 Ekip Dip LI 1SDA072521R1 1SDA073151R1 E4.2V 3200 Ekip Dip LSI 1SDA072522R1 1SDA073152R1 E4.2V 3200 Ekip Dip LSIG 1SDA072523R1 1SDA073153R1 E4.2V 3200 Ekip Touch LI 1SDA072524R1 1SDA073154R1 E4.2V 3200 Ekip Touch LSI 1SDA072525R1 1SDA073155R1 E4.2V 3200 Ekip Touch LSIG 1SDA072526R1 1SDA073156R1 E4.2V 3200 Ekip Hi-Touch LSI 1SDA072528R1 1SDA073158R1 E4.2V 3200 Ekip Hi-Touch LSIG 1SDA072529R1 1SDA073159R1 E4.2V 4000 Ekip Dip LI 1SDA072571R1 1SDA073201R1 E4.2V 4000 Ekip Dip LSI 1SDA072572R1 1SDA073202R1 E4.2V 4000 Ekip Dip LSIG 1SDA072573R1 1SDA073203R1 E4.2V 4000 Ekip Touch LI 1SDA072574R1 1SDA073204R1 E4.2V 4000 Ekip Touch LSI 1SDA072575R1 1SDA073205R1 E4.2V 4000 Ekip Touch LSIG 1SDA072576R1 1SDA073206R1 E4.2V 4000 Ekip Hi-Touch LSI 1SDA072578R1 1SDA073208R1 E4.2V 4000 Ekip Hi-Touch LSIG 1SDA072579R1 1SDA073209R1 9/30 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 30 15/04/2013 18:01:02 SACE Emax E6.2H-V • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size E6.2H Iu 4000 5000 6300 E6.2V 4000 5000 6300 Icu Icw (440 V) (1s) Type 100 100 100 150 150 150 100 100 100 100 100 100 3 Poles 4 Poles Code Code E6.2H 4000 Ekip Dip LI 1SDA072581R1 1SDA073211R1 E6.2H 4000 Ekip Dip LSI 1SDA072582R1 1SDA073212R1 E6.2H 4000 Ekip Dip LSIG 1SDA072583R1 1SDA073213R1 E6.2H 4000 Ekip Touch LI 1SDA072584R1 1SDA073214R1 E6.2H 4000 Ekip Touch LSI 1SDA072585R1 1SDA073215R1 E6.2H 4000 Ekip Touch LSIG 1SDA072586R1 1SDA073216R1 E6.2H 4000 Ekip Hi-Touch LSI 1SDA072588R1 1SDA073218R1 E6.2H 4000 Ekip Hi-Touch LSIG 1SDA072589R1 1SDA073219R1 E6.2H 5000 Ekip Dip LI 1SDA072611R1 1SDA073241R1 E6.2H 5000 Ekip Dip LSI 1SDA072612R1 1SDA073242R1 E6.2H 5000 Ekip Dip LSIG 1SDA072613R1 1SDA073243R1 E6.2H 5000 Ekip Touch LI 1SDA072614R1 1SDA073244R1 E6.2H 5000 Ekip Touch LSI 1SDA072615R1 1SDA073245R1 E6.2H 5000 Ekip Touch LSIG 1SDA072616R1 1SDA073246R1 E6.2H 5000 Ekip Hi-Touch LSI 1SDA072618R1 1SDA073248R1 E6.2H 5000 Ekip Hi-Touch LSIG 1SDA072619R1 1SDA073249R1 E6.2H 6300 Ekip Dip LI 1SDA072641R1 1SDA073271R1 E6.2H 6300 Ekip Dip LSI 1SDA072642R1 1SDA073272R1 E6.2H 6300 Ekip Dip LSIG 1SDA072643R1 1SDA073273R1 E6.2H 6300 Ekip Touch LI 1SDA072644R1 1SDA073274R1 E6.2H 6300 Ekip Touch LSI 1SDA072645R1 1SDA073275R1 E6.2H 6300 Ekip Touch LSIG 1SDA072646R1 1SDA073276R1 E6.2H 6300 Ekip Hi-Touch LSI 1SDA072648R1 1SDA073278R1 E6.2H 6300 Ekip Hi-Touch LSIG 1SDA072649R1 1SDA073279R1 E6.2V 4000 Ekip Dip LI 1SDA072591R1 1SDA073221R1 E6.2V 4000 Ekip Dip LSI 1SDA072592R1 1SDA073222R1 E6.2V 4000 Ekip Dip LSIG 1SDA072593R1 1SDA073223R1 E6.2V 4000 Ekip Touch LI 1SDA072594R1 1SDA073224R1 E6.2V 4000 Ekip Touch LSI 1SDA072595R1 1SDA073225R1 E6.2V 4000 Ekip Touch LSIG 1SDA072596R1 1SDA073226R1 E6.2V 4000 Ekip Hi-Touch LSI 1SDA072598R1 1SDA073228R1 E6.2V 4000 Ekip Hi-Touch LSIG 1SDA072599R1 1SDA073229R1 E6.2V 5000 Ekip Dip LI 1SDA072621R1 1SDA073251R1 E6.2V 5000 Ekip Dip LSI 1SDA072622R1 1SDA073252R1 E6.2V 5000 Ekip Dip LSIG 1SDA072623R1 1SDA073253R1 E6.2V 5000 Ekip Touch LI 1SDA072624R1 1SDA073254R1 E6.2V 5000 Ekip Touch LSI 1SDA072625R1 1SDA073255R1 E6.2V 5000 Ekip Touch LSIG 1SDA072626R1 1SDA073256R1 E6.2V 5000 Ekip Hi-Touch LSI 1SDA072628R1 1SDA073258R1 E6.2V 5000 Ekip Hi-Touch LSIG 1SDA072629R1 1SDA073259R1 E6.2V 6300 Ekip Dip LI 1SDA072651R1 1SDA073281R1 E6.2V 6300 Ekip Dip LSI 1SDA072652R1 1SDA073282R1 E6.2V 6300 Ekip Dip LSIG 1SDA072653R1 1SDA073283R1 E6.2V 6300 Ekip Touch LI 1SDA072654R1 1SDA073284R1 E6.2V 6300 Ekip Touch LSI 1SDA072655R1 1SDA073285R1 E6.2V 6300 Ekip Touch LSIG 1SDA072656R1 1SDA073286R1 E6.2V 6300 Ekip Hi-Touch LSI 1SDA072658R1 1SDA073288R1 E6.2V 6300 Ekip Hi-Touch LSIG 1SDA072659R1 1SDA073289R1 9 ABB Catalogue | 1SDC200023D0201 | 9/31 Emax2_cap09.indd 31 15/04/2013 18:01:05 Automatic circuit-breakers Withdrawable version for power distribution SACE Emax E6.2X • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size E6.2X Iu 4000 5000 6300 9 Icu Icw (440 V) (1s) Type 200 200 200 120 120 120 3 Poles 4 Poles Code Code E6.2X 4000 Ekip Dip LI 1SDA072601R1 1SDA073231R1 E6.2X 4000 Ekip Dip LSI 1SDA072602R1 1SDA073232R1 E6.2X 4000 Ekip Dip LSIG 1SDA072603R1 1SDA073233R1 E6.2X 4000 Ekip Touch LI 1SDA072604R1 1SDA073234R1 E6.2X 4000 Ekip Touch LSI 1SDA072605R1 1SDA073235R1 E6.2X 4000 Ekip Touch LSIG 1SDA072606R1 1SDA073236R1 E6.2X 4000 Ekip Hi-Touch LSI 1SDA072608R1 1SDA073238R1 E6.2X 4000 Ekip Hi-Touch LSIG 1SDA072609R1 1SDA073239R1 E6.2X 5000 Ekip Dip LI 1SDA072631R1 1SDA073261R1 E6.2X 5000 Ekip Dip LSI 1SDA072632R1 1SDA073262R1 E6.2X 5000 Ekip Dip LSIG 1SDA072633R1 1SDA073263R1 E6.2X 5000 Ekip Touch LI 1SDA072634R1 1SDA073264R1 E6.2X 5000 Ekip Touch LSI 1SDA072635R1 1SDA073265R1 E6.2X 5000 Ekip Touch LSIG 1SDA072636R1 1SDA073266R1 E6.2X 5000 Ekip Hi-Touch LSI 1SDA072638R1 1SDA073268R1 E6.2X 5000 Ekip Hi-Touch LSIG 1SDA072639R1 1SDA073269R1 E6.2X 6300 Ekip Dip LI 1SDA072661R1 1SDA073291R1 E6.2X 6300 Ekip Dip LSI 1SDA072662R1 1SDA073292R1 E6.2X 6300 Ekip Dip LSIG 1SDA072663R1 1SDA073293R1 E6.2X 6300 Ekip Touch LI 1SDA072664R1 1SDA073294R1 E6.2X 6300 Ekip Touch LSI 1SDA072665R1 1SDA073295R1 E6.2X 6300 Ekip Touch LSIG 1SDA072666R1 1SDA073296R1 E6.2X 6300 Ekip Hi-Touch LSI 1SDA072668R1 1SDA073298R1 E6.2X 6300 Ekip Hi-Touch LSIG 1SDA072669R1 1SDA073299R1 9/32 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 32 15/04/2013 18:01:08 SACE Emax E6.2H-V/f Full size • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size Iu Icu (440 V) Icw (1s) Type 4 Poles Code E6.2H/f 4000 5000 6300 E6.2V/f 4000 5000 6300 100 100 100 150 150 150 100 100 100 100 100 100 E6.2H/f 4000 Ekip Dip LI 1SDA073301R1 E6.2H/f 4000 Ekip Dip LSI 1SDA073302R1 E6.2H/f 4000 Ekip Dip LSIG 1SDA073303R1 E6.2H/f 4000 Ekip Touch LI 1SDA073304R1 E6.2H/f 4000 Ekip Touch LSI 1SDA073305R1 E6.2H/f 4000 Ekip Touch LSIG 1SDA073306R1 E6.2H/f 4000 Ekip Hi-Touch LSI 1SDA073308R1 E6.2H/f 4000 Ekip Hi-Touch LSIG 1SDA073309R1 E6.2H/f 5000 Ekip Dip LI 1SDA073331R1 E6.2H/f 5000 Ekip Dip LSI 1SDA073332R1 E6.2H/f 5000 Ekip Dip LSIG 1SDA073333R1 E6.2H/f 5000 Ekip Touch LI 1SDA073334R1 E6.2H/f 5000 Ekip Touch LSI 1SDA073335R1 E6.2H/f 5000 Ekip Touch LSIG 1SDA073336R1 E6.2H/f 5000 Ekip Hi-Touch LSI 1SDA073338R1 E6.2H/f 5000 Ekip Hi-Touch LSIG 1SDA073339R1 E6.2H/f 6300 Ekip Dip LI 1SDA073361R1 E6.2H/f 6300 Ekip Dip LSI 1SDA073362R1 E6.2H/f 6300 Ekip Dip LSIG 1SDA073363R1 E6.2H/f 6300 Ekip Touch LI 1SDA073364R1 E6.2H/f 6300 Ekip Touch LSI 1SDA073365R1 E6.2H/f 6300 Ekip Touch LSIG 1SDA073366R1 E6.2H/f 6300 Ekip Hi-Touch LSI 1SDA073368R1 E6.2H/f 6300 Ekip Hi-Touch LSIG 1SDA073369R1 E6.2V/f 4000 Ekip Dip LI 1SDA073311R1 E6.2V/f 4000 Ekip Dip LSI 1SDA073312R1 E6.2V/f 4000 Ekip Dip LSIG 1SDA073313R1 E6.2V/f 4000 Ekip Touch LI 1SDA073314R1 E6.2V/f 4000 Ekip Touch LSI 1SDA073315R1 E6.2V/f 4000 Ekip Touch LSIG 1SDA073316R1 E6.2V/f 4000 Ekip Hi-Touch LSI 1SDA073318R1 E6.2V/f 4000 Ekip Hi-Touch LSIG 1SDA073319R1 E6.2V/f 5000 Ekip Dip LI 1SDA073341R1 E6.2V/f 5000 Ekip Dip LSI 1SDA073342R1 E6.2V/f 5000 Ekip Dip LSIG 1SDA073343R1 E6.2V/f 5000 Ekip Touch LI 1SDA073344R1 E6.2V/f 5000 Ekip Touch LSI 1SDA073345R1 E6.2V/f 5000 Ekip Touch LSIG 1SDA073346R1 E6.2V/f 5000 Ekip Hi-Touch LSI 1SDA073348R1 E6.2V/f 5000 Ekip Hi-Touch LSIG 1SDA073349R1 E6.2V/f 6300 Ekip Dip LI 1SDA073371R1 E6.2V/f 6300 Ekip Dip LSI 1SDA073372R1 E6.2V/f 6300 Ekip Dip LSIG 1SDA073373R1 E6.2V/f 6300 Ekip Touch LI 1SDA073374R1 E6.2V/f 6300 Ekip Touch LSI 1SDA073375R1 E6.2V/f 6300 Ekip Touch LSIG 1SDA073376R1 E6.2V/f 6300 Ekip Hi-Touch LSI 1SDA073378R1 E6.2V/f 6300 Ekip Hi-Touch LSIG 1SDA073379R1 9 ABB Catalogue | 1SDC200023D0201 | 9/33 Emax2_cap09.indd 33 15/04/2013 18:01:10 Automatic circuit-breakers Withdrawable version for power distribution SACE Emax E6.2X/f Full size • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size Iu Icu (440 V) Icw (1s) Type 4 Poles Code E6.2X/f 4000 5000 6300 9 200 200 200 120 120 120 E6.2X/f 4000 Ekip Dip LI 1SDA073321R1 E6.2X/f 4000 Ekip Dip LSI 1SDA073322R1 E6.2X/f 4000 Ekip Dip LSIG 1SDA073323R1 E6.2X/f 4000 Ekip Touch LI 1SDA073324R1 E6.2X/f 4000 Ekip Touch LSI 1SDA073325R1 E6.2X/f 4000 Ekip Touch LSIG 1SDA073326R1 E6.2X/f 4000 Ekip Hi-Touch LSI 1SDA073328R1 E6.2X/f 4000 Ekip Hi-Touch LSIG 1SDA073329R1 E6.2X/f 5000 Ekip Dip LI 1SDA073351R1 E6.2X/f 5000 Ekip Dip LSI 1SDA073352R1 E6.2X/f 5000 Ekip Dip LSIG 1SDA073353R1 E6.2X/f 5000 Ekip Touch LI 1SDA073354R1 E6.2X/f 5000 Ekip Touch LSI 1SDA073355R1 E6.2X/f 5000 Ekip Touch LSIG 1SDA073356R1 E6.2X/f 5000 Ekip Hi-Touch LSI 1SDA073358R1 E6.2X/f 5000 Ekip Hi-Touch LSIG 1SDA073359R1 E6.2X/f 6300 Ekip Dip LI 1SDA073381R1 E6.2X/f 6300 Ekip Dip LSI 1SDA073382R1 E6.2X/f 6300 Ekip Dip LSIG 1SDA073383R1 E6.2X/f 6300 Ekip Touch LI 1SDA073384R1 E6.2X/f 6300 Ekip Touch LSI 1SDA073385R1 E6.2X/f 6300 Ekip Touch LSIG 1SDA073386R1 E6.2X/f 6300 Ekip Hi-Touch LSI 1SDA073388R1 E6.2X/f 6300 Ekip Hi-Touch LSIG 1SDA073389R1 9/34 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 34 15/04/2013 18:01:13 Automatic circuit-breakers Fixed version for generators 1SDC200661F001 SACE Emax E1.2B-C-N-L • Front terminals (F) Size E1.2B Iu 630 800 1000 1250 1600 E1.2C 42 E1.2B 630 Ekip G Touch LSIG 1SDA070707R1 1SDA071337R1 E1.2B 630 Ekip G Hi-Touch LSIG 1SDA070710R1 1SDA071340R1 42 42 42 42 42 42 42 42 42 50 42 800 50 42 1000 50 42 1600 50 50 42 42 250 66 50 630 66 50 800 66 50 1000 1250 1600 E1.2L Type 630 1250 E1.2N Icu Icw (440 V) (1s) 630 800 1000 1250 66 66 66 130 130 130 130 50 50 50 15 15 15 15 3 Poles 4 Poles Code Code E1.2B 800 Ekip G Touch LSIG 1SDA070747R1 1SDA071377R1 E1.2B 800 Ekip G Hi-Touch LSIG 1SDA070750R1 1SDA071380R1 E1.2B 1000 Ekip G Touch LSIG 1SDA070787R1 1SDA071417R1 E1.2B 1000 Ekip G Hi-Touch LSIG 1SDA070790R1 1SDA071420R1 E1.2B 1250 Ekip G Touch LSIG 1SDA070827R1 1SDA071457R1 E1.2B 1250 Ekip G Hi-Touch LSIG 1SDA070830R1 1SDA071460R1 E1.2B 1600 Ekip G Touch LSIG 1SDA071497R1 1SDA070867R1 E1.2B 1600 Ekip G Hi-Touch LSIG 1SDA070870R1 1SDA071500R1 E1.2C 630 Ekip G Touch LSIG 1SDA070717R1 1SDA071347R1 E1.2C 630 Ekip G Hi-Touch LSIG 1SDA070720R1 1SDA071350R1 E1.2C 800 Ekip G Touch LSIG 1SDA070757R1 1SDA071387R1 E1.2C 800 Ekip G Hi-Touch LSIG 1SDA070760R1 1SDA071390R1 E1.2C 1000 Ekip G Touch LSIG 1SDA070797R1 1SDA071427R1 E1.2C 1000 Ekip G Hi-Touch LSIG 1SDA070800R1 1SDA071430R1 E1.2C 1250 Ekip G Touch LSIG 1SDA070837R1 1SDA071467R1 E1.2C 1250 Ekip G Hi-Touch LSIG 1SDA070840R1 1SDA071470R1 E1.2C 1600 Ekip G Touch LSIG 1SDA070877R1 1SDA071507R1 E1.2C 1600 Ekip G Hi-Touch LSIG 1SDA070880R1 1SDA071510R1 E1.2N 250 Ekip G Touch LSIG 1SDA070697R1 1SDA071327R1 E1.2N 250 Ekip G Hi-Touch LSIG 1SDA070700R1 1SDA071330R1 E1.2N 630 Ekip G Touch LSIG 1SDA070727R1 1SDA071357R1 E1.2N 630 Ekip G Hi-Touch LSIG 1SDA070730R1 1SDA071360R1 E1.2N 800 Ekip G Touch LSIG 1SDA070767R1 1SDA071397R1 E1.2N 800 Ekip G Hi-Touch LSIG 1SDA070770R1 1SDA071400R1 E1.2N 1000 Ekip G Touch LSIG 1SDA070807R1 1SDA071437R1 E1.2N 1000 Ekip G Hi-Touch LSIG 1SDA070810R1 1SDA071440R1 E1.2N 1250 Ekip G Touch LSIG 1SDA070847R1 1SDA071477R1 E1.2N 1250 Ekip G Hi-Touch LSIG 1SDA070850R1 1SDA071480R1 E1.2N 1600 Ekip G Touch LSIG 1SDA070887R1 1SDA071517R1 E1.2N 1600 Ekip G Hi-Touch LSIG 1SDA070890R1 1SDA071520R1 E1.2L 630 Ekip G Touch LSIG 1SDA070737R1 1SDA071367R1 E1.2L 630 Ekip G Hi-Touch LSIG 1SDA070740R1 1SDA071370R1 E1.2L 800 Ekip G Touch LSIG 1SDA070777R1 1SDA071407R1 E1.2L 800 Ekip G Hi-Touch LSIG 1SDA070780R1 1SDA071410R1 E1.2L 1000 Ekip G Touch LSIG 1SDA070817R1 1SDA071447R1 E1.2L 1000 Ekip G Hi-Touch LSIG 1SDA070820R1 1SDA071450R1 E1.2L 1250 Ekip G Touch LSIG 1SDA070857R1 1SDA071487R1 E1.2L 1250 Ekip G Hi-Touch LSIG 1SDA070860R1 1SDA071490R1 9 ABB Catalogue | 1SDC200023D0201 | 9/35 Emax2_cap09.indd 35 15/04/2013 18:01:13 Automatic circuit-breakers Fixed version for generators 1SDC200662F001 SACE Emax E2.2B-N-S-H • Orientable rear terminals (HR) Size E2.2B Iu 1600 2000 E2.2N 800 1000 1250 1600 E2.2S 42 E2.2B 1600 Ekip G Touch LSIG 42 66 66 66 66 42 42 66 66 66 66 66 66 2500 66 66 250 85 85 66 66 1000 85 66 1250 85 66 1600 2000 2500 E2.2H Type 2000 800 9 Icu Icw (440 V) (1s) 800 1000 1250 1600 2000 2500 85 85 85 100 100 100 100 100 100 66 66 66 85 85 85 85 85 85 3 Poles 4 Poles Code Code 1SDA070987R1 1SDA071617R1 E2.2B 1600 Ekip G Hi-Touch LSIG 1SDA070990R1 1SDA071620R1 E2.2B 2000 Ekip G Touch LSIG 1SDA071027R1 1SDA071657R1 E2.2B 2000 Ekip G Hi-Touch LSIG 1SDA071030R1 1SDA071660R1 E2.2N 800 Ekip G Touch LSIG 1SDA070897R1 1SDA071527R1 E2.2N 800 Ekip G Hi-Touch LSIG 1SDA070900R1 1SDA071530R1 E2.2N 1000 Ekip G Touch LSIG 1SDA070927R1 1SDA071557R1 E2.2N 1000 Ekip G Hi-Touch LSIG 1SDA070930R1 1SDA071560R1 E2.2N 1250 Ekip G Touch LSIG 1SDA070957R1 1SDA071587R1 E2.2N 1250 Ekip G Hi-Touch LSIG 1SDA070960R1 1SDA071590R1 E2.2N 1600 Ekip G Touch LSIG 1SDA070997R1 1SDA071627R1 E2.2N 1600 Ekip G Hi-Touch LSIG 1SDA071000R1 1SDA071630R1 E2.2N 2000 Ekip G Touch LSIG 1SDA071037R1 1SDA071667R1 E2.2N 2000 Ekip G Hi-Touch LSIG 1SDA071040R1 1SDA071670R1 E2.2N 2500 Ekip G Touch LSIG 1SDA071067R1 1SDA071697R1 E2.2N 2500 Ekip G Hi-Touch LSIG 1SDA071070R1 1SDA071700R1 E2.2S 250 Ekip G Touch LSIG 1SDA073634R1 1SDA073644R1 E2.2S 250 Ekip G Hi-Touch LSIG 1SDA073637R1 1SDA073647R1 E2.2S 800 Ekip G Touch LSIG 1SDA070907R1 1SDA071537R1 E2.2S 800 Ekip G Hi-Touch LSIG 1SDA070910R1 1SDA071540R1 E2.2S 1000 Ekip G Touch LSIG 1SDA070937R1 1SDA071567R1 E2.2S 1000 Ekip G Hi-Touch LSIG 1SDA070940R1 1SDA071570R1 E2.2S 1250 Ekip G Touch LSIG 1SDA070967R1 1SDA071597R1 E2.2S 1250 Ekip G Hi-Touch LSIG 1SDA070970R1 1SDA071600R1 E2.2S 1600 Ekip G Touch LSIG 1SDA071007R1 1SDA071637R1 E2.2S 1600 Ekip G Hi-Touch LSIG 1SDA071010R1 1SDA071640R1 E2.2S 2000 Ekip G Touch LSIG 1SDA071047R1 1SDA071677R1 E2.2S 2000 Ekip G Hi-Touch LSIG 1SDA071050R1 1SDA071680R1 E2.2S 2500 Ekip G Touch LSIG 1SDA071077R1 1SDA071707R1 E2.2S 2500 Ekip G Hi-Touch LSIG 1SDA071080R1 1SDA071710R1 E2.2H 800 Ekip G Touch LSIG 1SDA070917R1 1SDA071547R1 E2.2H 800 Ekip G Hi-Touch LSIG 1SDA070920R1 1SDA071550R1 E2.2H 1000 Ekip G Touch LSIG 1SDA070947R1 1SDA071577R1 E2.2H 1000 Ekip G Hi-Touch LSIG 1SDA070950R1 1SDA071580R1 E2.2H 1250 Ekip G Touch LSIG 1SDA070977R1 1SDA071607R1 E2.2H 1250 Ekip G Hi-Touch LSIG 1SDA070980R1 1SDA071610R1 E2.2H 1600 Ekip G Touch LSIG 1SDA071017R1 1SDA071647R1 E2.2H 1600 Ekip G Hi-Touch LSIG 1SDA071020R1 1SDA071650R1 E2.2H 2000 Ekip G Touch LSIG 1SDA071057R1 1SDA071687R1 E2.2H 2000 Ekip G Hi-Touch LSIG 1SDA071060R1 1SDA071690R1 E2.2H 2500 Ekip G Touch LSIG 1SDA071087R1 1SDA071717R1 E2.2H 2500 Ekip G Hi-Touch LSIG 1SDA071090R1 1SDA071720R1 9/36 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 36 15/04/2013 18:01:14 1SDC200663F001 SACE Emax E4.2N-S-H-V • Orientable rear terminals (HR) Size E4.2N Iu 3200 4000 E4.2S 3200 4000 E4.2H 3200 4000 E4.2V Icu Icw (440 V) (1s) Type 66 E4.2N 3200 Ekip G Touch LSIG 66 85 85 100 100 66 66 66 66 85 85 2000 150 100 2500 150 100 3200 4000 150 150 100 100 3 Poles 4 Poles Code Code 1SDA071147R1 1SDA071777R1 E4.2N 3200 Ekip G Hi-Touch LSIG 1SDA071150R1 1SDA071780R1 E4.2N 4000 Ekip G Touch LSIG 1SDA071197R1 1SDA071827R1 E4.2N 4000 Ekip G Hi-Touch LSIG 1SDA071200R1 1SDA071830R1 E4.2S 3200 Ekip G Touch LSIG 1SDA071157R1 1SDA071787R1 E4.2S 3200 Ekip G Hi-Touch LSIG 1SDA071160R1 1SDA071790R1 E4.2S 4000 Ekip G Touch LSIG 1SDA071207R1 1SDA071837R1 E4.2S 4000 Ekip G Hi-Touch LSIG 1SDA071210R1 1SDA071840R1 E4.2H 3200 Ekip G Touch LSIG 1SDA071167R1 1SDA071797R1 E4.2H 3200 Ekip G Hi-Touch LSIG 1SDA071170R1 1SDA071800R1 E4.2H 4000 Ekip G Touch LSIG 1SDA071217R1 1SDA071847R1 E4.2H 4000 Ekip G Hi-Touch LSIG 1SDA071220R1 1SDA071850R1 E4.2V 2000 Ekip G Touch LSIG 1SDA071107R1 1SDA071737R1 E4.2V 2000 Ekip G Hi-Touch LSIG 1SDA071110R1 1SDA071740R1 E4.2V 2500 Ekip G Touch LSIG 1SDA071127R1 1SDA071757R1 E4.2V 2500 Ekip G Hi-Touch LSIG 1SDA071130R1 1SDA071760R1 E4.2V 3200 Ekip G Touch LSIG 1SDA071177R1 1SDA071807R1 E4.2V 3200 Ekip G Hi-Touch LSIG 1SDA071180R1 1SDA071810R1 E4.2V 4000 Ekip G Touch LSIG 1SDA071227R1 1SDA071857R1 E4.2V 4000 Ekip G Hi-Touch LSIG 1SDA071230R1 1SDA071860R1 9 ABB Catalogue | 1SDC200023D0201 | 9/37 Emax2_cap09.indd 37 15/04/2013 18:01:14 Automatic circuit-breakers Fixed version for generators SACE Emax E6.2H-V-X • Orientable rear terminals (HR) 1SDC200664F001 Size E6.2H Iu 4000 5000 6300 E6.2V 4000 5000 6300 E6.2X Icu Icw (440 V) (1s) Type 100 E6.2H 4000 Ekip G Touch LSIG 100 100 150 150 150 100 100 100 100 100 100 4000 200 120 5000 200 120 6300 200 120 3 Poles 4 Poles Code Code 1SDA071237R1 1SDA071867R1 E6.2H 4000 Ekip G Hi-Touch LSIG 1SDA071240R1 1SDA071870R1 E6.2H 5000 Ekip G Touch LSIG 1SDA071267R1 1SDA071897R1 E6.2H 5000 Ekip G Hi-Touch LSIG 1SDA071270R1 1SDA071900R1 E6.2H 6300 Ekip G Touch LSIG 1SDA071297R1 1SDA071927R1 E6.2H 6300 Ekip G Hi-Touch LSIG 1SDA071300R1 1SDA071930R1 E6.2V 4000 Ekip G Touch LSIG 1SDA071247R1 1SDA071877R1 E6.2V 4000 Ekip G Hi-Touch LSIG 1SDA071250R1 1SDA071880R1 E6.2V 5000 Ekip G Touch LSIG 1SDA071277R1 1SDA071907R1 E6.2V 5000 Ekip G Hi-Touch LSIG 1SDA071280R1 1SDA071910R1 E6.2V 6300 Ekip G Touch LSIG 1SDA071307R1 1SDA071937R1 E6.2V 6300 Ekip G Hi-Touch LSIG 1SDA071310R1 1SDA071940R1 E6.2X 4000 Ekip G Touch LSIG 1SDA071257R1 1SDA071887R1 E6.2X 4000 Ekip G Hi-Touch LSIG 1SDA071260R1 1SDA071890R1 E6.2X 5000 Ekip G Touch LSIG 1SDA071287R1 1SDA071917R1 E6.2X 5000 Ekip G Hi-Touch LSIG 1SDA071290R1 1SDA071920R1 E6.2X 6300 Ekip G Touch LSIG 1SDA071317R1 1SDA071947R1 E6.2X 6300 Ekip G Hi-Touch LSIG 1SDA071320R1 1SDA071950R1 9 9/38 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 38 15/04/2013 18:01:15 SACE Emax E6.2H-V-X/f Full size • Orientable rear terminals (HR) 1SDC200664F001 Size E6.2H/f Iu 4000 5000 6300 E6.2V/f Icw (1s) 100 100 100 100 100 100 150 100 5000 150 100 150 100 4000 200 120 5000 200 120 6300 200 Type 4 Poles Code 4000 6300 E6.2X/f Icu (440 V) 120 E6.2H/f 4000 Ekip G Touch LSIG 1SDA071957R1 E6.2H/f 4000 Ekip G Hi-Touch LSIG 1SDA071960R1 E6.2H/f 5000 Ekip G Touch LSIG 1SDA071987R1 E6.2H/f 5000 Ekip G Hi-Touch LSIG 1SDA071990R1 E6.2H/f 6300 Ekip G Touch LSIG 1SDA072017R1 E6.2H/f 6300 Ekip G Hi-Touch LSIG 1SDA072020R1 E6.2V/f 4000 Ekip G Touch LSIG 1SDA071967R1 E6.2V/f 4000 Ekip G Hi-Touch LSIG 1SDA071970R1 E6.2V/f 5000 Ekip G Touch LSIG 1SDA071997R1 E6.2V/f 5000 Ekip G Hi-Touch LSIG 1SDA072000R1 E6.2V/f 6300 Ekip G Touch LSIG 1SDA072027R1 E6.2V/f 6300 Ekip G Hi-Touch LSIG 1SDA072030R1 E6.2X/f 4000 Ekip G Touch LSIG 1SDA071977R1 E6.2X/f 4000 Ekip G Hi-Touch LSIG 1SDA071980R1 E6.2X/f 5000 Ekip G Touch LSIG 1SDA072007R1 E6.2X/f 5000 Ekip G Hi-Touch LSIG 1SDA072010R1 E6.2X/f 6300 Ekip G Touch LSIG 1SDA072037R1 E6.2X/f 6300 Ekip G Hi-Touch LSIG 1SDA072040R1 9 ABB Catalogue | 1SDC200023D0201 | 9/39 Emax2_cap09.indd 39 15/04/2013 18:01:15 Automatic circuit-breakers Withdrawable version for generators 1SDC200665F001 SACE Emax E1.2B-C-N-L • Mobile part of withdrawable circuit-breaker (MP) Size E1.2B Iu 630 800 1000 1250 1600 E1.2C 630 E1.2B 630 Ekip G Touch LSIG 1SDA072057R1 1SDA072687R1 E1.2B 630 Ekip G Hi-Touch LSIG 1SDA072060R1 1SDA072690R1 42 42 42 42 50 42 42 42 42 42 42 42 1000 50 42 50 50 42 42 250 66 50 630 66 50 800 1000 1250 1600 E1.2L 42 50 1600 9 Type 800 1250 E1.2N Icu Icw (440 V) (1s) 630 800 1000 1250 66 66 66 66 130 130 130 130 50 50 50 50 15 15 15 15 3 Poles 4 Poles Code Code E1.2B 800 Ekip G Touch LSIG 1SDA072097R1 1SDA072727R1 E1.2B 800 Ekip G Hi-Touch LSIG 1SDA072100R1 1SDA072730R1 E1.2B 1000 Ekip G Touch LSIG 1SDA072137R1 1SDA072767R1 E1.2B 1000 Ekip G Hi-Touch LSIG 1SDA072140R1 1SDA072770R1 E1.2B 1250 Ekip G Touch LSIG 1SDA072177R1 1SDA072807R1 E1.2B 1250 Ekip G Hi-Touch LSIG 1SDA072180R1 1SDA072810R1 E1.2B 1600 Ekip G Touch LSIG 1SDA072217R1 1SDA072847R1 E1.2B 1600 Ekip G Hi-Touch LSIG 1SDA072220R1 1SDA072850R1 E1.2C 630 Ekip G Touch LSIG 1SDA072067R1 1SDA072697R1 E1.2C 630 Ekip G Hi-Touch LSIG 1SDA072070R1 1SDA072700R1 E1.2C 800 Ekip G Touch LSIG 1SDA072107R1 1SDA072737R1 E1.2C 800 Ekip G Hi-Touch LSIG 1SDA072110R1 1SDA072740R1 E1.2C 1000 Ekip G Touch LSIG 1SDA072147R1 1SDA072777R1 E1.2C 1000 Ekip G Hi-Touch LSIG 1SDA072150R1 1SDA072780R1 E1.2C 1250 Ekip G Touch LSIG 1SDA072187R1 1SDA072817R1 E1.2C 1250 Ekip G Hi-Touch LSIG 1SDA072190R1 1SDA072820R1 E1.2C 1600 Ekip G Touch LSIG 1SDA072227R1 1SDA072857R1 E1.2C 1600 Ekip G Hi-Touch LSIG 1SDA072230R1 1SDA072860R1 E1.2N 250 Ekip G Touch LSIG 1SDA072047R1 1SDA072677R1 E1.2N 250 Ekip G Hi-Touch LSIG 1SDA072050R1 1SDA072680R1 E1.2N 630 Ekip G Touch LSIG 1SDA072077R1 1SDA072707R1 E1.2N 630 Ekip G Hi-Touch LSIG 1SDA072080R1 1SDA072710R1 E1.2N 800 Ekip G Touch LSIG 1SDA072117R1 1SDA072747R1 E1.2N 800 Ekip G Hi-Touch LSIG 1SDA072120R1 1SDA072750R1 E1.2N 1000 Ekip G Touch LSIG 1SDA072157R1 1SDA072787R1 E1.2N 1000 Ekip G Hi-Touch LSIG 1SDA072160R1 1SDA072790R1 E1.2N 1250 Ekip G Touch LSIG 1SDA072197R1 1SDA072827R1 E1.2N 1250 Ekip G Hi-Touch LSIG 1SDA072200R1 1SDA072830R1 E1.2N 1600 Ekip G Touch LSIG 1SDA072237R1 1SDA072867R1 E1.2N 1600 Ekip G Hi-Touch LSIG 1SDA072240R1 1SDA072870R1 E1.2L 630 Ekip G Touch LSIG 1SDA072087R1 1SDA072717R1 E1.2L 630 Ekip G Hi-Touch LSIG 1SDA072090R1 1SDA072720R1 E1.2L 800 Ekip G Touch LSIG 1SDA072127R1 1SDA072757R1 E1.2L 800 Ekip G Hi-Touch LSIG 1SDA072130R1 1SDA072760R1 E1.2L 1000 Ekip G Touch LSIG 1SDA072167R1 1SDA072797R1 E1.2L 1000 Ekip G Hi-Touch LSIG 1SDA072170R1 1SDA072800R1 E1.2L 1250 Ekip G Touch LSIG 1SDA072207R1 1SDA072837R1 E1.2L 1250 Ekip G Hi-Touch LSIG 1SDA072210R1 1SDA072840R1 9/40 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 40 15/04/2013 18:01:16 SACE Emax E2.2B-N-S-H • Mobile part of withdrawable circuit-breaker (MP) 1SDC200666F001 Size E2.2B Iu 1600 2000 E2.2N 800 1000 1250 1600 E2.2S Type 42 E2.2B 1600 Ekip G Touch LSIG 42 66 66 66 66 42 42 66 66 66 66 2000 66 66 2500 66 66 250 800 85 85 66 66 1000 85 66 1250 85 66 1600 85 66 2000 2500 E2.2H Icu Icw (440 V) (1s) 800 1000 1250 1600 2000 2500 85 85 100 100 100 100 100 100 66 66 85 85 85 85 85 85 3 Poles 4 Poles Code Code 1SDA072337R1 1SDA072967R1 E2.2B 1600 Ekip G Hi-Touch LSIG 1SDA072340R1 1SDA072970R1 E2.2B 2000 Ekip G Touch LSIG 1SDA072377R1 1SDA073007R1 E2.2B 2000 Ekip G Hi-Touch LSIG 1SDA072380R1 1SDA073010R1 E2.2N 800 Ekip G Touch LSIG 1SDA072247R1 1SDA072877R1 E2.2N 800 Ekip G Hi-Touch LSIG 1SDA072250R1 1SDA072880R1 E2.2N 1000 Ekip G Touch LSIG 1SDA072277R1 1SDA072907R1 E2.2N 1000 Ekip G Hi-Touch LSIG 1SDA072280R1 1SDA072910R1 E2.2N 1250 Ekip G Touch LSIG 1SDA072307R1 1SDA072937R1 E2.2N 1250 Ekip G Hi-Touch LSIG 1SDA072310R1 1SDA072940R1 E2.2N 1600 Ekip G Touch LSIG 1SDA072347R1 1SDA072977R1 E2.2N 1600 Ekip G Hi-Touch LSIG 1SDA072350R1 1SDA072980R1 E2.2N 2000 Ekip G Touch LSIG 1SDA072387R1 1SDA073017R1 E2.2N 2000 Ekip G Hi-Touch LSIG 1SDA072390R1 1SDA073020R1 E2.2N 2500 Ekip G Touch LSIG 1SDA072417R1 1SDA073047R1 E2.2N 2500 Ekip G Hi-Touch LSIG 1SDA072420R1 1SDA073050R1 E2.2S 250 Ekip G Touch LSIG 1SDA073654R1 1SDA073664R1 E2.2S 250 Ekip G Hi-Touch LSIG 1SDA073657R1 1SDA073667R1 E2.2S 800 Ekip G Touch LSIG 1SDA072257R1 1SDA072887R1 E2.2S 800 Ekip G Hi-Touch LSIG 1SDA072260R1 1SDA072890R1 E2.2S 1000 Ekip G Touch LSIG 1SDA072287R1 1SDA072917R1 E2.2S 1000 Ekip G Hi-Touch LSIG 1SDA072290R1 1SDA072920R1 E2.2S 1250 Ekip G Touch LSIG 1SDA072317R1 1SDA072947R1 E2.2S 1250 Ekip G Hi-Touch LSIG 1SDA072320R1 1SDA072950R1 E2.2S 1600 Ekip G Touch LSIG 1SDA072357R1 1SDA072987R1 E2.2S 1600 Ekip G Hi-Touch LSIG 1SDA072360R1 1SDA072990R1 E2.2S 2000 Ekip G Touch LSIG 1SDA072397R1 1SDA073027R1 E2.2S 2000 Ekip G Hi-Touch LSIG 1SDA072400R1 1SDA073030R1 E2.2S 2500 Ekip G Touch LSIG 1SDA072427R1 1SDA073057R1 E2.2S 2500 Ekip G Hi-Touch LSIG 1SDA072430R1 1SDA073060R1 E2.2H 800 Ekip G Touch LSIG 1SDA072267R1 1SDA072897R1 E2.2H 800 Ekip G Hi-Touch LSIG 1SDA072270R1 1SDA072900R1 E2.2H 1000 Ekip G Touch LSIG 1SDA072297R1 1SDA072927R1 E2.2H 1000 Ekip G Hi-Touch LSIG 1SDA072300R1 1SDA072930R1 E2.2H 1250 Ekip G Touch LSIG 1SDA072327R1 1SDA072957R1 E2.2H 1250 Ekip G Hi-Touch LSIG 1SDA072330R1 1SDA072960R1 E2.2H 1600 Ekip G Touch LSIG 1SDA072367R1 1SDA072997R1 E2.2H 1600 Ekip G Hi-Touch LSIG 1SDA072370R1 1SDA073000R1 E2.2H 2000 Ekip G Touch LSIG 1SDA072407R1 1SDA073037R1 E2.2H 2000 Ekip G Hi-Touch LSIG 1SDA072410R1 1SDA073040R1 E2.2H 2500 Ekip G Touch LSIG 1SDA072437R1 1SDA073067R1 E2.2H 2500 Ekip G Hi-Touch LSIG 1SDA072440R1 1SDA073070R1 9 ABB Catalogue | 1SDC200023D0201 | 9/41 Emax2_cap09.indd 41 15/04/2013 18:01:18 Automatic circuit-breakers Withdrawable version for generators SACE Emax E4.2N-S-H-V • Mobile part of withdrawable circuit-breaker (MP) 1SDC200667F001 Size E4.2N Iu 3200 4000 E4.2S 3200 4000 E4.2H 3200 4000 E4.2V Icu Icw (440 V) (1s) Type 66 E4.2N 3200 Ekip G Touch LSIG 66 85 85 100 100 66 66 66 66 85 85 2000 150 100 2500 150 100 3200 4000 150 150 100 100 3 Poles 4 Poles Code Code 1SDA072497R1 1SDA073127R1 E4.2N 3200 Ekip G Hi-Touch LSIG 1SDA072500R1 1SDA073130R1 E4.2N 4000 Ekip G Touch LSIG 1SDA072547R1 1SDA073177R1 E4.2N 4000 Ekip G Hi-Touch LSIG 1SDA072550R1 1SDA073180R1 E4.2S 3200 Ekip G Touch LSIG 1SDA072507R1 1SDA073137R1 E4.2S 3200 Ekip G Hi-Touch LSIG 1SDA072510R1 1SDA073140R1 E4.2S 4000 Ekip G Touch LSIG 1SDA072557R1 1SDA073187R1 E4.2S 4000 Ekip G Hi-Touch LSIG 1SDA072560R1 1SDA073190R1 E4.2H 3200 Ekip G Touch LSIG 1SDA072517R1 1SDA073147R1 E4.2H 3200 Ekip G Hi-Touch LSIG 1SDA072520R1 1SDA073150R1 E4.2H 4000 Ekip G Touch LSIG 1SDA072567R1 1SDA073197R1 E4.2H 4000 Ekip G Hi-Touch LSIG 1SDA072570R1 1SDA073200R1 E4.2V 2000 Ekip G Touch LSIG 1SDA072457R1 1SDA073087R1 E4.2V 2000 Ekip G Hi-Touch LSIG 1SDA072460R1 1SDA073090R1 E4.2V 2500 Ekip G Touch LSIG 1SDA072477R1 1SDA073107R1 E4.2V 2500 Ekip G Hi-Touch LSIG 1SDA072480R1 1SDA073110R1 E4.2V 3200 Ekip G Touch LSIG 1SDA072527R1 1SDA073157R1 E4.2V 3200 Ekip G Hi-Touch LSIG 1SDA072530R1 1SDA073160R1 E4.2V 4000 Ekip G Touch LSIG 1SDA072577R1 1SDA073207R1 E4.2V 4000 Ekip G Hi-Touch LSIG 1SDA072580R1 1SDA073210R1 9 9/42 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 42 15/04/2013 18:01:19 SACE Emax E6.2H-V-X • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size E6.2H Iu 4000 5000 6300 E6.2V 4000 5000 6300 E6.2X Icu Icw (440 V) (1s) Type 100 E6.2H 4000 Ekip G Touch LSIG 100 100 150 150 150 100 100 100 100 100 100 4000 200 120 5000 200 120 6300 200 120 3 Poles 4 Poles Code Code 1SDA072587R1 1SDA073217R1 E6.2H 4000 Ekip G Hi-Touch LSIG 1SDA072590R1 1SDA073220R1 E6.2H 5000 Ekip G Touch LSIG 1SDA072617R1 1SDA073247R1 E6.2H 5000 Ekip G Hi-Touch LSIG 1SDA072620R1 1SDA073250R1 E6.2H 6300 Ekip G Touch LSIG 1SDA072647R1 1SDA073277R1 E6.2H 6300 Ekip G Hi-Touch LSIG 1SDA072650R1 1SDA073280R1 E6.2V 4000 Ekip G Touch LSIG 1SDA072597R1 1SDA073227R1 E6.2V 4000 Ekip G Hi-Touch LSIG 1SDA072600R1 1SDA073230R1 E6.2V 5000 Ekip G Touch LSIG 1SDA072627R1 1SDA073257R1 E6.2V 5000 Ekip G Hi-Touch LSIG 1SDA072630R1 1SDA073260R1 E6.2V 6300 Ekip G Touch LSIG 1SDA072657R1 1SDA073287R1 E6.2V 6300 Ekip G Hi-Touch LSIG 1SDA072660R1 1SDA073290R1 E6.2X 4000 Ekip G Touch LSIG 1SDA072607R1 1SDA073237R1 E6.2X 4000 Ekip G Hi-Touch LSIG 1SDA072610R1 1SDA073240R1 E6.2X 5000 Ekip G Touch LSIG 1SDA072637R1 1SDA073267R1 E6.2X 5000 Ekip G Hi-Touch LSIG 1SDA072640R1 1SDA073270R1 E6.2X 6300 Ekip G Touch LSIG 1SDA072667R1 1SDA073297R1 E6.2X 6300 Ekip G Hi-Touch LSIG 1SDA072670R1 1SDA073300R1 9 ABB Catalogue | 1SDC200023D0201 | 9/43 Emax2_cap09.indd 43 15/04/2013 18:01:22 Automatic circuit-breakers Withdrawable version per generators SACE Emax E6.2H-V-X/f Full size • Mobile part of withdrawable circuit-breaker (MP) 1SDC200668F001 Size E6.2H/f Iu 4000 5000 6300 E6.2V/f 4000 5000 6300 E6.2X/f Icu (440 V) Icw (1s) 100 100 100 100 150 150 150 100 100 100 100 100 200 120 5000 200 120 200 4 Poles Code 4000 6300 Type 120 E6.2H/f 4000 Ekip G Touch LSIG 1SDA073307R1 E6.2H/f 4000 Ekip G Hi-Touch LSIG 1SDA073310R1 E6.2H/f 5000 Ekip G Touch LSIG 1SDA073337R1 E6.2H/f 5000 Ekip G Hi-Touch LSIG 1SDA073340R1 E6.2H/f 6300 Ekip G Touch LSIG 1SDA073367R1 E6.2H/f 6300 Ekip G Hi-Touch LSIG 1SDA073370R1 E6.2V/f 4000 Ekip G Touch LSIG 1SDA073317R1 E6.2V/f 4000 Ekip G Hi-Touch LSIG 1SDA073320R1 E6.2V/f 5000 Ekip G Touch LSIG 1SDA073347R1 E6.2V/f 5000 Ekip G Hi-Touch LSIG 1SDA073350R1 E6.2V/f 6300 Ekip G Touch LSIG 1SDA073377R1 E6.2V/f 6300 Ekip G Hi-Touch LSIG 1SDA073380R1 E6.2X/f 4000 Ekip G Touch LSIG 1SDA073327R1 E6.2X/f 4000 Ekip G Hi-Touch LSIG 1SDA073330R1 E6.2X/f 5000 Ekip G Touch LSIG 1SDA073357R1 E6.2X/f 5000 Ekip G Hi-Touch LSIG 1SDA073360R1 E6.2X/f 6300 Ekip G Touch LSIG 1SDA073387R1 E6.2X/f 6300 Ekip G Hi-Touch LSIG 1SDA073390R1 9 9/44 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 44 15/04/2013 18:01:24 Switch-disconnectors Fixed version 1SDC200669F001 SACE Emax E1.2B-N/MS • Fixed terminals (F) Size E1.2B/MS E1.2N/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 630 42 E1.2B/MS 630 1SDA073392R1 1SDA073431R1 800 42 E1.2B/MS 800 1SDA073394R1 1SDA073433R1 1000 42 E1.2B/MS 1000 1SDA073396R1 1SDA073435R1 1250 42 E1.2B/MS 1250 1SDA073398R1 1SDA073437R1 1600 42 E1.2B/MS 1600 1SDA073400R1 1SDA073439R1 250 50 E1.2N/MS 250 1SDA073391R1 1SDA073430R1 630 50 E1.2N/MS 630 1SDA073393R1 1SDA073432R1 800 50 E1.2N/MS 800 1SDA073395R1 1SDA073434R1 1000 50 E1.2N/MS 1000 1SDA073397R1 1SDA073436R1 1250 50 E1.2N/MS 1250 1SDA073399R1 1SDA073438R1 1600 50 E1.2N/MS 1600 1SDA073401R1 1SDA073440R1 1SDC200670F001 SACE Emax E2.2B-N-H/MS • Orientable rear terminals (HR) 3 Poles 4 Poles Code Code 1SDA073408R1 1SDA073447R1 Size Iu Icw (1s) Type E2.2B/MS 1600 42 E2.2B/MS 1600 2000 42 E2.2B/MS 2000 1SDA073411R1 1SDA073450R1 800 66 E2.2N/MS 800 1SDA073402R1 1SDA073441R1 1000 66 E2.2N/MS 1000 1SDA073404R1 1SDA073443R1 1250 66 E2.2N/MS 1250 1SDA073406R1 1SDA073445R1 1600 66 E2.2N/MS 1600 1SDA073409R1 1SDA073448R1 2000 66 E2.2N/MS 2000 1SDA073412R1 1SDA073451R1 2500 66 E2.2N/MS 2500 1SDA073414R1 1SDA073453R1 800 85 E2.2H/MS 800 1SDA073403R1 1SDA073442R1 1000 85 E2.2H/MS 1000 1SDA073405R1 1SDA073444R1 1250 85 E2.2H/MS 1250 1SDA073407R1 1SDA073446R1 1600 85 E2.2H/MS 1600 1SDA073410R1 1SDA073449R1 2000 85 E2.2H/MS 2000 1SDA073413R1 1SDA073452R1 2500 85 E2.2H/MS 2500 1SDA073415R1 1SDA073454R1 E2.2N/MS E2.2H/MS 9 ABB Catalogue | 1SDC200023D0201 | 9/45 Emax2_cap09.indd 45 15/04/2013 18:01:25 Switch-disconnectors Fixed version SACE Emax E4.2N-H-V/MS • Orientable rear terminals (HR) 1SDC200671F001 Size E4.2N/MS E4.2H/MS E4.2V/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 1SDA073457R1 3200 66 E4.2N/MS 3200 1SDA073418R1 4000 66 E4.2N/MS 4000 1SDA073421R1 1SDA073460R1 3200 85 E4.2H/MS 3200 1SDA073419R1 1SDA073458R1 4000 85 E4.2H/MS 4000 1SDA073422R1 1SDA073461R1 2000 100 E4.2V/MS 2000 1SDA073416R1 1SDA073455R1 2500 100 E4.2V/MS 2500 1SDA073417R1 1SDA073456R1 3200 100 E4.2V/MS 3200 1SDA073420R1 1SDA073459R1 4000 100 E4.2V/MS 4000 1SDA073423R1 1SDA073462R1 SACE Emax E6.2H-X/MS • Orientable rear terminals (HR) 1SDC200672F001 Size E6.2H/MS E6.2X/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 4000 100 E6.2H/MS 4000 1SDA073424R1 1SDA073463R1 5000 100 E6.2H/MS 5000 1SDA073426R1 1SDA073465R1 6300 100 E6.2H/MS 6300 1SDA073428R1 1SDA073467R1 4000 120 E6.2X/MS 4000 1SDA073425R1 1SDA073464R1 5000 120 E6.2X/MS 5000 1SDA073427R1 1SDA073466R1 6300 120 E6.2X/MS 6300 1SDA073429R1 1SDA073468R1 9 9/46 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 46 15/04/2013 18:01:26 SACE Emax E6.2H-X/MS/f Full size • Orientable rear terminals (HR) 1SDC200672F001 Size Iu Icw (1s) Type 4 Poles Code E6.2H/MS/f E6.2X/MS/f 4000 100 E6.2H/MS/f 4000 1SDA073469R1 5000 100 E6.2H/MS/f 5000 1SDA073471R1 6300 100 E6.2H/MS/f 6300 1SDA073473R1 4000 120 E6.2X/MS/f 4000 1SDA073470R1 5000 120 E6.2X/MS/f 5000 1SDA073472R1 6300 120 E6.2X/MS/f 6300 1SDA073474R1 9 ABB Catalogue | 1SDC200023D0201 | 9/47 Emax2_cap09.indd 47 15/04/2013 18:01:26 Switch-disconnectors Withdrawable version SACE Emax E1.2B-N/MS • Mobile part of withdrawable circuit-breaker (MP) 1SDC200673F001 Size E1.2B/MS E1.2N/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 630 42 E1.2B/MS 630 1SDA073476R1 1SDA073515R1 800 42 E1.2B/MS 800 1SDA073478R1 1SDA073517R1 1000 42 E1.2B/MS 1000 1SDA073480R1 1SDA073519R1 1250 42 E1.2B/MS 1250 1SDA073482R1 1SDA073521R1 1600 42 E1.2B/MS 1600 1SDA073484R1 1SDA073523R1 250 50 E1.2N/MS 250 1SDA073475R1 1SDA073514R1 630 50 E1.2N/MS 630 1SDA073477R1 1SDA073516R1 800 50 E1.2N/MS 800 1SDA073479R1 1SDA073518R1 1000 50 E1.2N/MS 1000 1SDA073481R1 1SDA073520R1 1250 50 E1.2N/MS 1250 1SDA073483R1 1SDA073522R1 1600 50 E1.2N/MS 1600 1SDA073485R1 1SDA073524R1 1SDC200674F001 SACE Emax E2.2B-N-H/MS • Mobile part of withdrawable circuit-breaker (MP) 3 Poles 4 Poles Code Code 1SDA073492R1 1SDA073531R1 E2.2B/MS 2000 1SDA073495R1 1SDA073534R1 66 E2.2N/MS 800 1SDA073486R1 1SDA073525R1 1000 66 E2.2N/MS 1000 1SDA073488R1 1SDA073527R1 1250 66 E2.2N/MS 1250 1SDA073490R1 1SDA073529R1 1600 66 E2.2N/MS 1600 1SDA073493R1 1SDA073532R1 2000 66 E2.2N/MS 2000 1SDA073496R1 1SDA073535R1 2500 66 E2.2N/MS 2500 1SDA073498R1 1SDA073537R1 800 85 E2.2H/MS 800 1SDA073487R1 1SDA073526R1 1000 85 E2.2H/MS 1000 1SDA073489R1 1SDA073528R1 1250 85 E2.2H/MS 1250 1SDA073491R1 1SDA073530R1 1600 85 E2.2H/MS 1600 1SDA073494R1 1SDA073533R1 2000 85 E2.2H/MS 2000 1SDA073497R1 1SDA073536R1 2500 85 E2.2H/MS 2500 1SDA073499R1 1SDA073538R1 Size Iu Icw (1s) Type E2.2B/MS 1600 42 E2.2B/MS 1600 2000 42 800 E2.2N/MS 9 E2.2H/MS 9/48 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 48 15/04/2013 18:01:29 SACE Emax E4.2N-H-V/MS • Mobile part of withdrawable circuit-breaker (MP) 1SDC200675F001 Size E4.2N/MS E4.2H/MS E4.2V/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 1SDA073541R1 3200 66 E4.2N/MS 3200 1SDA073502R1 4000 66 E4.2N/MS 4000 1SDA073505R1 1SDA073544R1 3200 85 E4.2H/MS 3200 1SDA073503R1 1SDA073542R1 4000 85 E4.2H/MS 4000 1SDA073506R1 1SDA073545R1 2000 100 E4.2V/MS 2000 1SDA073500R1 1SDA073539R1 2500 100 E4.2V/MS 2500 1SDA073501R1 1SDA073540R1 3200 100 E4.2V/MS 3200 1SDA073504R1 1SDA073543R1 4000 100 E4.2V/MS 4000 1SDA073507R1 1SDA073546R1 SACE Emax E6.2H-X/MS • Mobile part of withdrawable circuit-breaker (MP) 1SDC200676F001 Size E6.2H/MS E6.2X/MS Iu Icw (1s) Type 3 Poles 4 Poles Code Code 4000 100 E6.2H/MS 4000 1SDA073508R1 1SDA073547R1 5000 100 E6.2H/MS 5000 1SDA073510R1 1SDA073549R1 6300 100 E6.2H/MS 6300 1SDA073512R1 1SDA073551R1 4000 120 E6.2X/MS 4000 1SDA073509R1 1SDA073548R1 5000 120 E6.2X/MS 5000 1SDA073511R1 1SDA073550R1 6300 120 E6.2X/MS 6300 1SDA073513R1 1SDA073552R1 SACE Emax E6.2H-X/MS/f Full size • Mobile part of withdrawable circuit-breaker (MP) Size Iu Icw (1s) Type 4 Poles E6.2H/MS/f 4000 100 E6.2H/MS/f 4000 1SDA073553R1 5000 100 E6.2H/MS/f 5000 1SDA073555R1 6300 100 E6.2H/MS/f 6300 1SDA073557R1 4000 120 E6.2X/MS/f 4000 1SDA073554R1 5000 120 E6.2X/MS/f 5000 1SDA073556R1 6300 120 E6.2X/MS/f 6300 1SDA073558R1 Code E6.2X/MS/f 9 ABB Catalogue | 1SDC200023D0201 | 9/49 Emax2_cap09.indd 49 15/04/2013 18:01:33 Automatic circuit-breakers and switch-disconnectors Version for applications up to 1150V AC Size Iu Icu (1150 V) Icw (1s) Type 3 Poles 4 Poles Code Code E1.2N/E 630 25 25 E1.2N/E 630 Upgrade Kit 1150V AC 1SDA074316R1 1SDA074321R1 E1.2N/E 800 25 25 E1.2N/E 800 Upgrade Kit 1150V AC 1SDA074317R1 1SDA074322R1 E1.2N/E 1000 25 25 E1.2N/E 1000 Upgrade Kit 1150V AC 1SDA074318R1 1SDA074323R1 E1.2N/E 1250 25 25 E1.2N/E 1250 Upgrade Kit 1150V AC 1SDA074319R1 1SDA074324R1 E1.2N/E 1600 25 25 E1.2N/E 1600 Upgrade Kit 1150V AC 1SDA074320R1 1SDA074325R1 E2.2H/E 800 30 30 E2.2H/E 800 Upgrade Kit 1150V AC 1SDA074326R1 1SDA074332R1 E2.2H/E 1000 30 30 E2.2H/E 1000 Upgrade Kit 1150V AC 1SDA074327R1 1SDA074333R1 E2.2H/E 1250 30 30 E2.2H/E 1250 Upgrade Kit 1150V AC 1SDA074328R1 1SDA074334R1 E2.2H/E 1600 30 30 E2.2H/E 1600 Upgrade Kit 1150V AC 1SDA074329R1 1SDA074335R1 E2.2H/E 2000 30 30 E2.2H/E 2000 Upgrade Kit 1150V AC 1SDA074330R1 1SDA074336R1 E2.2H/E 2500 30 30 E2.2H/E 2500 Upgrade Kit 1150V AC 1SDA074331R1 1SDA074337R1 E4.2H/E 3200 50 50 E4.2H/E 3200 Upgrade Kit 1150V AC 1SDA074338R1 1SDA074340R1 E4.2H/E 4000 50 50 E4.2H/E 4000 Upgrade Kit 1150V AC 1SDA074339R1 1SDA074341R1 E6.2X/E 4000 65 65 E6.2X/E 4000 Upgrade Kit 1150V AC 1SDA074342R1 1SDA074345R1 E6.2X/E 5000 65 65 E6.2X/E 5000 Upgrade Kit 1150V AC 1SDA074343R1 1SDA074346R1 E6.2X/E 6300 65 65 E6.2X/E 6300 Upgrade Kit 1150V AC 1SDA074344R1 1SDA074347R1 9 9/50 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 50 15/04/2013 18:01:33 Switch-disconnectors Fixed version for applications up to 1000V DC Size Iu Icu (1000 V) Icw (1s) Type 3 Poles 4 Poles Code Code E1.2N/DC/MS 800 E1.2N/DC/MS 800A 750-1000V DC 1SDA074381R1 1SDA074382R1 E1.2N/DC/MS 1250 E1.2N/DC/MS 1250A 750-1000V DC 1SDA074383R1 1SDA074384R1 E2.2S/DC/MS 1250 E2.2S/DC/MS 1250A 750-1000V DC 1SDA074389R1 1SDA074390R1 E2.2S/DC/MS 1600 E2.2S/DC/MS 1600A 750-1000V DC 1SDA074391R1 1SDA074392R1 E2.2S/DC/MS 2000 E2.2S/DC/MS 2000A 750-1000V DC 1SDA074393R1 1SDA074394R1 E2.2S/DC/MS 2500 E2.2S/DC/MS 2500A 750-1000V DC 1SDA074395R1 1SDA074396R1 E4.2H/DC/MS 1250 E4.2H/DC/MS 1250A 750-1000V DC 1SDA074405R1 1SDA074406R1 E4.2H/DC/MS 1600 E4.2H/DC/MS 1600A 750-1000V DC 1SDA074407R1 1SDA074408R1 E4.2H/DC/MS 2000 E4.2H/DC/MS 2000A 750-1000V DC 1SDA074409R1 1SDA074410R1 E4.2H/DC/MS 2500 E4.2H/DC/MS 2500A 750-1000V DC 1SDA074411R1 1SDA074412R1 E4.2H/DC/MS 3200 E4.2H/DC/MS 3200A 750-1000V DC 1SDA074413R1 1SDA074414R1 E4.2H/DC/MS 4000 E4.2H/DC/MS 4000A 750-1000V DC 1SDA074415R1 1SDA074416R1 E6.2X/DC/MS 4000 E6.2X/DC/MS 4000A 750-1000V DC 1SDA074429R1 1SDA074430R1 E6.2X/DC/MS 5000 E6.2X/DC/MS 5000A 750-1000V DC 1SDA074431R1 1SDA074432R1 E6.2X/DC/MS 6300 E6.2X/DC/MS 6300A 750-1000V DC 1SDA074433R1 1SDA074434R1 9 ABB Catalogue | 1SDC200023D0201 | 9/51 Emax2_cap09.indd 51 15/04/2013 18:01:33 Switch-disconnectors Withdrawable version for applications up to 1000V DC Withdrawable version - Mobile part Size Iu Icu (1000 V) Icw (1s) Type 3 Poles 4 Poles Code Code E1.2N/DC/MS 800 E1.2N/DC/MS 800A 750-1000VDC 1SDA074385R1 1SDA074386R1 E1.2N/DC/MS 1250 E1.2N/DC/MS 1250A 750-1000VDC 1SDA074387R1 1SDA074388R1 E2.2S/DC/MS 1250 E2.2S/DC/MS 1250A 750-1000VDC 1SDA074397R1 1SDA074398R1 E2.2S/DC/MS 1600 E2.2S/DC/MS 1600A 750-1000VDC 1SDA074399R1 1SDA074400R1 E2.2S/DC/MS 2000 E2.2S/DC/MS 2000A 750-1000VDC 1SDA074401R1 1SDA074402R1 E2.2S/DC/MS 2500 E2.2S/DC/MS 2500A 750-1000VDC 1SDA074403R1 1SDA074404R1 E4.2H/DC/MS 1250 E4.2H/DC/MS 1250A 750-1000VDC 1SDA074417R1 1SDA074418R1 E4.2H/DC/MS 1600 E4.2H/DC/MS 1600A 750-1000VDC 1SDA074419R1 1SDA074420R1 E4.2H/DC/MS 2000 E4.2H/DC/MS 2000A 750-1000VDC 1SDA074421R1 1SDA074422R1 E4.2H/DC/MS 2500 E4.2H/DC/MS 2500A 750-1000VDC 1SDA074423R1 1SDA074424R1 E4.2H/DC/MS 3200 E4.2H/DC/MS 3200A 750-1000VDC 1SDA074425R1 1SDA074426R1 E4.2H/DC/MS 4000 E4.2H/DC/MS 4000A 750-1000VDC 1SDA074427R1 1SDA074428R1 E6.2X/DC/MS 4000 E6.2X/DC/MS 4000A 750-1000VDC 1SDA074435R1 1SDA074436R1 E6.2X/DC/MS 5000 E6.2X/DC/MS 5000A 750-1000VDC 1SDA074437R1 1SDA074438R1 E6.2X/DC/MS 6300 E6.2X/DC/MS 6300A 750-1000VDC 1SDA074439R1 1SDA074440R1 Withdrawable version - Fixed part Size 9 Iu Type of terminal Type 3 Poles 4 Poles Code Code E1.2 1600 HR - HR E1.2DC W FP Iu=1600 HR HR 1SDA073923R1 1SDA073924R1 E2.2 2000 HR - HR E2.2DC W FP Iu=2000 HR HR 1SDA073925R1 1SDA073926R1 E2.2 2500 HR - HR E2.2DC W FP Iu=2500 HR HR 1SDA073927R1 1SDA073928R1 E4.2 3200 HR - HR E4.2DC W FP Iu=3200 HR HR 1SDA073929R1 1SDA073930R1 E4.2 / E4.2V 4000 HR - HR E4.2DC W FP Iu=4000 or V HR HR version 1SDA073931R1 1SDA073932R1 E6.2 5000 HR - HR E6.2DC W FP Iu=5000 HR HR 1SDA073933R1 E6.2/f 5000 HR - HR E6.2DC W FP Iu=5000 HR HR E6.2 / E6.2X 6300 HR - HR E6.2DC W FP Iu=6300 HR HR E6.2/f / E6.2X/f 6300 HR - HR E6.2DC W FP Iu=6300 HR HR 1SDA073935R1 1SDA073936R1 1SDA073938R1 9/52 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 52 15/04/2013 18:01:33 Derived versions Sectionalizing truck - CS Size Iu Type 3 poles 4 poles Code Code E2.2/CS 2500 E2.2/CS 2500 MP 3p 1SDA074348R1 1SDA074349R1 E4.2/CS 4000 E4.2/CS 4000 MP 3p 1SDA074350R1 1SDA074351R1 E6.2/CS 6300 E6.2/CS 6300 MP 3p 1SDA074352R1 1SDA074353R1 Earthing truck - MT Size Iu Type 3 poles 4 poles Code Code E2.2 MT 2500 E2.2MT 2500 MP Earth connection from upper terminals 1SDA074354R1 1SDA074355R1 E4.2 MT 4000 E4.2MT 4000 MP Earth connection from upper terminals 1SDA074356R1 1SDA074357R1 E6.2 MT 6300 E6.2MT 6300 MP Earth connection from upper terminals 1SDA074358R1 1SDA074359R1 E2.2 MT 2500 E2.2MT 2500 MP Earth connection from lower terminals 1SDA074360R1 1SDA074361R1 E4.2 MT 4000 E4.2MT 4000 MP Earth connection from lower terminals 1SDA074362R1 1SDA074363R1 E6.2 MT 6300 E6.2MT 6300 MP Earth connection from lower terminals 1SDA074364R1 1SDA074365R1 3 poles 4 poles Earthing switch with making capacity - MTP Size Iu Type Code Code E2.2 MTP 2500 E2.2MTP 2500 MP Earth connection from upper terminals 1SDA074366R1 1SDA074367R1 E4.2 MTP 4000 E4.2MTP 4000 MP Earth connection from upper terminals 1SDA074368R1 1SDA074369R1 E6.2 MTP 6300 E6.2MTP 6300 MP Earth connection from upper terminals 1SDA074370R1 1SDA074371R1 E2.2 MTP 2500 E2.2MTP 2500 MP Earth connection from lower terminals 1SDA074372R1 1SDA074373R1 E4.2 MTP 4000 E4.2MTP 4000 MP Earth connection from lower terminals 1SDA074374R1 1SDA074375R1 E6.2 MTP 6300 E6.2MTP 6300 MP Earth connection from lower terminals 1SDA074376R1 1SDA074377R1 9 Accessories for MT and MTP Size Type Code E2.2 Grounding clamp PF E2.2 for MT/MTP 1SDA074378R1 E4.2 Grounding clamp PF E4.2 for MT/MTP 1SDA074379R1 E6.2 Grounding clamp PF E6.2 for MT/MTP 1SDA074380R1 ABB Catalogue | 1SDC200023D0201 | 9/53 Emax2_cap09.indd 53 15/04/2013 18:01:33 Fixed parts Performance Iu Type of terminal Type 3 Poles 4 Poles Code Code E1.2 B, C, N, L 1600 HR - HR E1.2 W FP Iu=1600 HR HR 1SDA073907R1 1SDA073908R1 E2.2 B, N, S, H 2000 HR - HR E2.2 W FP Iu=2000 HR HR 1SDA073909R1 1SDA073910R1 E2.2 N, S, H 2500 HR - HR E2.2 W FP Iu=2500 HR HR 1SDA073911R1 1SDA073912R1 E4.2 N, S, H 3200 HR - HR E4.2 W FP Iu=3200 HR HR 1SDA073913R1 1SDA073914R1 E4.2 N, S, H, V 4000 HR - HR E4.2 W FP Iu=4000 or V HR HR version 1SDA073915R1 1SDA073916R1 E6.2 H, V 5000 HR - HR E6.2 W FP Iu=5000 HR HR 1SDA073917R1 1SDA073918R1 E6.2/f H, V 5000 HR - HR E6.2 W FP Iu=5000 HR HR E6.2 H, V, X 6300 HR - HR E6.2X W FP Iu=6300 or X HR HR version E6.2/f H, V, X 6300 HR - HR E6.2 W FP Iu=6300 or X HR HR version 1SDA073919R1 1SDA073920R1 1SDA073921R1 1SDA073922R1 1SDC200679F001 1SDC200678F001 1SDC200677F001 Size 1SDC200680F001 9 9/54 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 54 15/04/2013 18:01:42 Accessories Electrical accessories 1SDC200510F001 First and second opening release - YO Size Type Code E1.2..E6.2 YO E1.2..E6.2 24V AC/DC 1SDA073668R1 E1.2..E6.2 YO E1.2..E6.2 30V AC/DC 1SDA073669R1 E1.2..E6.2 YO E1.2..E6.2 48V AC/DC 1SDA073670R1 E1.2..E6.2 YO E1.2..E6.2 60V AC/DC 1SDA073671R1 E1.2..E6.2 YO E1.2..E6.2 110-120V AC/DC 1SDA073672R1 E1.2..E6.2 YO E1.2..E6.2 120-127V AC/DC 1SDA073673R1 E1.2..E6.2 YO E1.2..E6.2 220-240V AC/DC 1SDA073674R1 E1.2..E6.2 YO E1.2..E6.2 240-250V AC/DC 1SDA073675R1 E1.2..E6.2 YO E1.2..E6.2 380-400V AC 1SDA073677R1 E1.2..E6.2 YO E1.2..E6.2 415-440V AC 1SDA073678R1 E1.2..E6.2 YO E1.2..E6.2 480-500V AC 1SDA073679R1 First and second closing release- YC Size Type Code E1.2..E6.2 YC E1.2..E6.2 24V AC/DC 1SDA073681R1 E1.2..E6.2 YC E1.2..E6.2 30V AC/DC 1SDA073682R1 E1.2..E6.2 YC E1.2..E6.2 48V AC/DC 1SDA073683R1 E1.2..E6.2 YC E1.2..E6.2 60V AC/DC 1SDA073684R1 E1.2..E6.2 YC E1.2..E6.2 110-120V AC/DC 1SDA073685R1 E1.2..E6.2 YC E1.2..E6.2 120-127V AC/DC 1SDA073686R1 E1.2..E6.2 YC E1.2..E6.2 220-240V AC/DC 1SDA073687R1 E1.2..E6.2 YC E1.2..E6.2 240-250V AC/DC 1SDA073688R1 E1.2..E6.2 YC E1.2..E6.2 380-400V AC 1SDA073690R1 E1.2..E6.2 YC E1.2..E6.2 415-440V AC 1SDA073691R1 E1.2..E6.2 YC E1.2..E6.2 480-500V AC 1SDA073692R1 9 YO/YC test unit Size Type Code E1.2...E6.2 YO/YC test unit E1.2...E6.2 1SDA073707R1 Undervoltage release - YU Size Type Code E1.2..E6.2 YU E1.2..E6.2 24V AC/DC 1SDA073694R1 E1.2..E6.2 YU E1.2..E6.2 30V AC/DC 1SDA073695R1 E1.2..E6.2 YU E1.2..E6.2 48V AC/DC 1SDA073696R1 E1.2..E6.2 YU E1.2..E6.2 60V AC/DC 1SDA073697R1 E1.2..E6.2 YU E1.2..E6.2 110-120V AC/DC 1SDA073698R1 E1.2..E6.2 YU E1.2..E6.2 120-127V AC/DC 1SDA073699R1 E1.2..E6.2 YU E1.2..E6.2 220-240V AC/DC 1SDA073700R1 E1.2..E6.2 YU E1.2..E6.2 240-250V AC/DC 1SDA073701R1 E1.2..E6.2 YU E1.2..E6.2 380-400V AC 1SDA073703R1 E1.2..E6.2 YU E1.2..E6.2 415-440V AC 1SDA073704R1 E1.2..E6.2 YU E1.2..E6.2 480-500V AC 1SDA073705R1 Electronic time-delay device for undervoltage release - UVD Size Type Code E1.2...E6.2 24...30V DC 1SDA074623R1 E1.2...E6.2 48V AC/DC 1SDA074624R1 E1.2...E6.2 60V AC/DC 1SDA074625R1 E1.2...E6.2 110...127V AC/DC 1SDA074626R1 E1.2...E6.2 220...250V AC/DC 1SDA074627R1 ABB Catalogue | 1SDC200023D0201 | 9/55 Emax2_cap09.indd 55 15/04/2013 18:01:43 Accessories Electrical accessories 1SDC200514F001 1SDC200513F001 1SDC200512F001 1SDC200511F001 Remote Reset - YR 1SDC200556F001 1SDC200555F001 9 Size Type Code E1.2 YR 24V DC E1.2 1SDA073744R1 E1.2 YR 110V AC/DC E1.2 1SDA073745R1 E1.2 YR 250V AC/DC E1.2 1SDA073746R1 E2.2...E6.2 YR 24V DC E2.2...E6.2 1SDA073747R1 E2.2...E6.2 YR 110V AC/DC E2.2...E6.2 1SDA073748R1 E2.2...E6.2 YR 250V AC/DC E2.2...E6.2 1SDA073749R1 Motor - M Size Type Code E1.2 M E1.2 24-30V AC/DC 1SDA073708R1 E1.2 M E1.2 48-60V AC/DC 1SDA073709R1 E1.2 M E1.2 100-130V AC/DC 1SDA073710R1 E1.2 M E1.2 220-250V AC/DC 1SDA073711R1 E1.2 M E1.2 380-415V AC 1SDA073713R1 E1.2 M E1.2 440-480V AC 1SDA073714R1 E2.2...E6.2 M E2.2...E6.2 24-30V AC/DC 1SDA073722R1 E2.2...E6.2 M E2.2...E6.2 48-60V AC/DC 1SDA073723R1 E2.2...E6.2 M E2.2...E6.2 100-130V AC/DC 1SDA073724R1 E2.2...E6.2 M E2.2...E6.2 220-250V AC/DC 1SDA073725R1 E2.2...E6.2 M E2.2...E6.2 380-415V AC 1SDA073727R1 E2.2...E6.2 M E2.2...E6.2 440-480V AC 1SDA073728R1 E1.2 M E1.2 24-30V AC/DC + S33 M/2 24V DC 1SDA073715R1 E1.2 M E1.2 48-60V AC/DC + S33 M/2 24V DC 1SDA073716R1 E1.2 M E1.2 100-130V AC/DC + S33 M/2 24V DC 1SDA073717R1 E1.2 M E1.2 220-250V AC/DC + S33 M/2 24V DC 1SDA073718R1 E1.2 M E1.2 380-415V AC + S33 M/2 24V DC 1SDA073720R1 E1.2 M E1.2 440-480V AC + S33 M/2 24V DC 1SDA073721R1 E2.2...E6.2 M E2.2...E6.2 24-30V AC/DC + S33 M/2 24V DC 1SDA073729R1 E2.2...E6.2 M E2.2...E6.2 48-60V AC/DC + S33 M/2 24V DC 1SDA073730R1 E2.2...E6.2 M E2.2...E6.2 100-130V AC/DC + S33 M/2 24V DC 1SDA073731R1 E2.2...E6.2 M E2.2...E6.2 220-250V AC/DC + S33 M/2 24V DC 1SDA073732R1 E2.2...E6.2 M E2.2...E6.2 380-415V AC + S33 M/2 24V DC 1SDA073734R1 E2.2...E6.2 M E2.2...E6.2 440-480V AC + S33 M/2 24V DC 1SDA073735R1 Current sensor for neutral conductor outside the circuit-breaker Size Type Code E1.2 Ext CS N E1.2 E2.2 2000A 1SDA073736R1 E2.2 Ext CS N E2.2 2500A 1SDA073737R1 E4.2 Ext CS N E4.2 3200A 1SDA073738R1 E6.2 Ext CS N E4.2 4000A E6.2 50% 1SDA073739R1 E6.2 Ext CS N E6.2 1SDA073740R1 Homopolar toroid for the earthing conductor of main power supply Size Type Code E1.2..E6.2 Homopolar toroid E1.2 … E6.2 1SDA073743R1 1SDC200557F001 Toroid for differential protection Size Type Code E1.2 - E2.2 3p Toroid RC E1.2, E2.2 3p 1SDA073741R1 E2.2 4p - E4.2 Toroid RC E2.2 4p, E4.2 1SDA073742R1 9/56 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 56 15/04/2013 18:01:45 1SDC200503F001 1SDC200505F001 1SDC200504F001 Open/closed auxiliary contacts - AUX Type Code E1.2 AUX 4Q 400V E1.2 1SDA073750R1 E1.2 AUX 4Q 24V E1.2 1SDA073751R1 E1.2 AUX 2Q 400V + 2Q 24V E1.2 1SDA073752R1 E2.2...E6.2 AUX 4Q 400V E2.2...E6.2 1SDA073753R1 E2.2...E6.2 AUX 4Q 24V E2.2...E6.2 1SDA073754R1 E2.2...E6.2 AUX 2Q 400V + 2Q 24V E2.2...E6.2 1SDA073755R1 E2.2...E6.2 AUX 6Q 400V E2.2...E6.2 1SDA073756R1 E2.2...E6.2 AUX 6Q 24V E2.2...E6.2 1SDA073757R1 E2.2...E6.2 AUX 3Q 400V AC + 3Q 24V DC E2.2...E6.2 1SDA075973R1 E1.2 AUX 15Q 400V E1.2 * 1SDA073758R1 E1.2 AUX 15Q 24V E1.2 * 1SDA073759R1 E2.2...E6.2 AUX 15Q 400V E2.2...E6.2 * 1SDA073760R1 E2.2...E6.2 AUX 15Q 24V E2.2...E6.2 * 1SDA073761R1 * not compatible with mechanical locks on compartment doors or mechanical interlocks; must be ordered with interlock support. 1SDC200506F001 Auxiliary position contacts - AUP 1SDC200507F001 1SDC200508F001 Size Size Type Code E1.2 AUP 6 contacts 400V E1.2 1SDA073762R1 E1.2 AUP 6 contacts 24V E1.2 1SDA073763R1 E2.2...E6.2 AUP 5 contacts 400V E2.2...E6.2 - left set 1SDA073764R1 E2.2...E6.2 AUP 5 contacts 24V E2.2...E6.2 - left set 1SDA073765R1 E2.2...E6.2 AUP 5 suppl. contacts 400V E2.2...E6.2 - right set 1SDA073766R1 E2.2...E6.2 AUP 5 suppl. contacts 24V E2.2...E6.2 - right set 1SDA073767R1 E1.2 AUP Ekip aux. contacts position E1.2 1SDA073768R1 E2.2...E6.2 AUP Ekip aux. contacts position E2.2..E6.2 1SDA073769R1 9 Ready to close signalling contact- RTC Size Type Code E1.2 RTC 250V E1.2 1SDA073770R1 E1.2 RTC 24V E1.2 1SDA073771R1 E1.2 RTC Ekip 24V E1.2 1SDA073772R1 E2.2...E6.2 RTC 250V E2.2...E6.2 1SDA073773R1 E2.2...E6.2 RTC 24V E2.2...E6.2 1SDA073774R1 E2.2...E6.2 RTC Ekip 24V E2.2...E6.2 1SDA073775R1 Contact signalling tripping of Ekip protection trip unit - S51 Size Type Code E1.2 S51 250V E1.2 1SDA073776R1 E1.2 S51 24V E1.2 1SDA073777R1 E2.2...E6.2 S51 250V E2.2...E6.2 1SDA073778R1 E2.2...E6.2 S51 24V E2.2...E6.2 1SDA073779R1 1SDC200681F001 Terminals for auxiliary connection Size Type Code E1.2..E6.2 Terminals 10 pcs 1SDA073906R1 ABB Catalogue | 1SDC200023D0201 | 9/57 Emax2_cap09.indd 57 15/04/2013 18:01:48 1SDC200524F001 Accessories Mechanical accessories Mechanical operation counter - MOC Size Type Code E1.2 MOC Mechanical operation counter 1SDA073780R1 E2.2...E6.2 MOC Mechanical operation counter 1SDA073781R1 1SDC200516F001 1SDC200515F001 Key lock in open position - KLC 9 Size Type Code E1.2 KLC-D Bl. Key lock open E1.2 1SDA073782R1 E1.2 KLC-S Bl. Key lock open N.20005 E1.2 1SDA073783R1 E1.2 KLC-S Bl. Key lock open N.20006 E1.2 1SDA073784R1 E1.2 KLC-S Bl. Key lock open N.20007 E1.2 1SDA073785R1 E1.2 KLC-S Bl. Key lock open N.20008 E1.2 1SDA073786R1 E1.2 KLC-S Bl. Key lock open N.20009 E1.2 1SDA073787R1 E1.2 KLA Bl. Castell key lock open E1.2 1SDA073788R1 E1.2 KLA Bl. Kirk key lock open E1.2 1SDA073789R1 E1.2 KLA Bl. Ronis Profalux key lock open E1.2 1SDA073790R1 E2.2...E6.2 KLC-D Bl. Key lock open E2.2...E6.2 1SDA073791R1 E2.2...E6.2 KLC-S Bl. key lock AP N.20005 E2.2..E6.2 1SDA073792R1 E2.2...E6.2 KLC-S Bl. key lock AP N.20006 E2.2..E6.2 1SDA073793R1 E2.2...E6.2 KLC-S Bl. key lock AP N.20007 E2.2..E6.2 1SDA073794R1 E2.2...E6.2 KLC-S Bl. key lock AP N.20008 E2.2..E6.2 1SDA073795R1 E2.2...E6.2 KLC-S Bl. key lock AP N.20009 E2.2..E6.2 1SDA073796R1 E2.2...E6.2 KLA Bl. Castell key lock open E2.2...E6.2 1SDA073797R1 E2.2...E6.2 KLA Bl. AP Castell Kirk key lock E2.2..E6.2 1SDA073798R1 E2.2...E6.2 KLA Bl. AP Ronis Profalux key lock E2.2..E6.2 1SDA073799R1 1SDC200518F001 1SDC200517F001 Padlocks in open position - PLC Size Type Code E1.2 PLC E1.2 Bl. Padlocks in open position D=4mm 1SDA073800R1 E1.2 PLC E1.2 Bl. Padlocks in open position D=7mm 1SDA073801R1 E1.2 PLC E1.2 Bl. Padlocks in open position D=8mm 1SDA073802R1 E2.2...E6.2 PLC E2.2..E6.2 Bl. Padlocks in open position D=4mm 1SDA073803R1 E2.2...E6.2 PLC E2.2..E6.2 Bl. Padlocks in open position D=7mm 1SDA073804R1 E2.2...E6.2 PLC E2.2..E6.2 Bl. Padlocks in open position D=8mm 1SDA073805R1 9/58 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 58 15/04/2013 18:01:50 1SDC200519F001 1SDC200520F001 Key lock in racked-in / test / racked-out position- KLP Size Type Code E1.2 KLP-D Bl. Racked in/out E1.2 1st key 1SDA073822R1 E1.2 KLP-S Bl. Racked in/out N.20005 E1.2 1st key 1SDA073823R1 E1.2 KLP-S Bl. Racked in/out N.20006 E1.2 1st key 1SDA073824R1 E1.2 KLP-S Bl. Racked in/out N.20007 E1.2 1st key 1SDA073825R1 E1.2 KLP-S Bl. Racked in/out N.20008 E1.2 1st key 1SDA073826R1 E1.2 KLP-S Bl. Racked in/out N.20009 E1.2 1st key 1SDA073827R1 E1.2 KLP-D Bl. Racked in/out E1.2 2nd key 1SDA073828R1 E1.2 KLP-S Bl. Racked in/out N.20005 E1.2 2nd key 1SDA073829R1 E1.2 KLP-S Bl. Racked in/out N.20006 E1.2 2nd key 1SDA073830R1 E1.2 KLP-S Bl. Racked in/out N.20007 E1.2 2nd key 1SDA073831R1 E1.2 KLP-S Bl. Racked in/out N.20008 E1.2 2nd key 1SDA073832R1 E1.2 KLP-S Bl. Racked in/out N.20009 E1.2 2nd key 1SDA073833R1 E1.2 KLP-A Bl. Racked in/out RonProf Kirk E1.2 1st key 1SDA073834R1 E1.2 KLP-A Bl. Racked in/out RonProf Kirk E1.2 2nd key 1SDA073835R1 E1.2 KLP-A Bl. Racked in/out Castell E1.2 1st key 1SDA073836R1 E1.2 KLP-A Bl. Racked in/out Castell E1.2 2nd key 1SDA073837R1 E2.2...E6.2 KLP-D Bl. Racked in/out E2.2...E6.2 1st key 1SDA073806R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20005 E2.2..E6.2 1st key 1SDA073807R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20006 E2.2..E6.2 1st key 1SDA073808R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20007 E2.2..E6.2 1st key 1SDA073809R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20008 E2.2..E6.2 1st key 1SDA073810R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20009 E2.2..E6.2 1st key 1SDA073811R1 E2.2...E6.2 KLP-D Bl. Racked in/out E2.2...E6.2 2nd key 1SDA073812R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20005 E2.2..E6.2 2nd key 1SDA073813R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20006 E2.2..E6.2 2nd key 1SDA073814R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20007 E2.2..E6.2 2nd key 1SDA073815R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20008 E2.2..E6.2 2nd key 1SDA073816R1 E2.2...E6.2 KLP-S Bl. Racked in/out N.20009 E2.2..E6.2 2nd key 1SDA073817R1 E2.2...E6.2 KLP-A Bl. Racked in/out RoProKirk E2.2..E6.2 1st key 1SDA073818R1 E2.2...E6.2 KLP-A Bl. Racked in/out RoProKirk E2.2..E6.2 2nd key 1SDA073819R1 E2.2...E6.2 KLP-A Bl. Racked in/out Castell E2.2..E6.2 1st key 1SDA073820R1 E2.2...E6.2 KLP-A Bl. Racked in/out Castell E2.2..E6.2 2nd key 1SDA073821R1 9 1SDC200521F001 Accessory for supplementary lock in racked-out position Size Type Code E1.2 Suppl. locks in racked-out E1.2 1SDA073838R1 E2.2...E6.2 Suppl. locks in racked-out E2.2...E6.2 1SDA073839R1 Padlock in racked-in / test / racked-out position - PLP Size Type Code E1.2 PLP Bl. padlocks Racked in/out D=4/6/8mm E1.2 1SDA073840R1 E2.2...E6.2 PLP Bl. padlocks Racked in/out D=4/6/8mm E2.2..E6.2 1SDA073841R1 1SDC200522F001 External shutter lock- SLE Size Type Code E2.2 SLE Bl. shutter lock D=4/6/8mm E2.2 1SDA073842R1 E4.2 SLE Bl. shutter lock D=4/6/8mm E4.2 1SDA073843R1 E6.2 SLE Bl. shutter lock D=4/6/8mm E6.2 1SDA073844R1 ABB Catalogue | 1SDC200023D0201 | 9/59 Emax2_cap09.indd 59 15/04/2013 18:01:52 Accessories Mechanical accessories Lock for racking in / racking out the mobile part when the door is open - DLR Size Type Code E2.2 DLR E2.2 1SDA073845R1 E4.2 DLR E4.2 1SDA073846R1 E6.2 DLR E6.2 1SDA073847R1 1SDC200523F001 Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP Size Type Code E2.2...E6.2 DLP E2.2...E6.2 1SDA073849R1 Lock to prevent door opening when circuit-breaker is in closed position - DLC Size Type Code E1.2 DLC Interlock cable door E1.2 1SDA073850R1 E1.2 DLC Interlock direct door E1.2 1SDA073851R1 E2.2...E6.2 DLC Interlock cable door E2.2...E6.2 1SDA073852R1 E2.2...E6.2 DLC Interlock direct door E2.2…E6.2 1SDA073853R1 1SDC200525F001 1SDC200526F001 Protection device for opening and closing pushbuttons - PBC 9 Size Type Code E1.2 PBC Prot. Pushbuttons AP/CH E1.2 1SDA073854R1 E1.2 PBC Prot. Pushbuttons AP/CH D=4mm E1.2 1SDA073855R1 E1.2 PBC Prot. Pushbuttons AP/CH D=7mm E1.2 1SDA073856R1 E1.2 PBC Prot. Pushbuttons AP/CH D=8mm E1.2 1SDA073857R1 E2.2...E6.2 PBC Prot. Pushbuttons AP/CH E2.2...E6.2 1SDA073858R1 E2.2...E6.2 PBC Prot. Pushbuttons AP/CH D=4mm E2.2..E6.2 1SDA073859R1 E2.2...E6.2 PBC Prot. Pushbuttons AP/CH D=7mm E2.2..E6.2 1SDA073860R1 E2.2...E6.2 PBC Prot. Pushbuttons AP/CH D=8mm E2.2..E6.2 1SDA073861R1 1SDC200529F001 1SDC200528F001 1SDC200527F001 Circuit-breaker flange Size Type Code E1.2 IP30 Flange E1.2 F 1SDA073862R1 E1.2 IP30 Flange E1.2 W 1SDA073863R1 E2.2...E6.2 IP30 Flange E2.2...E6.2 F 1SDA073864R1 E2.2...E6.2 IP30 Flange E2.2...E6.2 W 1SDA073865R1 E1.2 IP54 Flange different keys E1.2 1SDA073866R1 E2.2...E6.2 IP54 Flange different keys E2.2...E6.2 1SDA073867R1 E1.2 IP54 Flange key No. 20005 E1.2 1SDA073868R1 E2.2...E6.2 IP54 Flange key No. 20005 E2.2...E6.2 1SDA073869R1 E2.2...E6.2 Sealable trip unit cover 1SDA073870R1 High or low terminal covers- HTC/LTC 1SDC200530F001 Size Type 3 poles 4 poles Code Code E1.2 HTC high terminal covers E1.2 2pcs 1SDA073871R1 1SDA073872R1 E1.2 LTC low terminal covers E1.2 F 2pcs 1SDA073873R1 1SDA073874R1 E1.2 LTC low terminal covers E1.2 W 2pcs 1SDA073875R1 1SDA073876R1 1SDC200531F001 Separators - PB Size Type Code E1.2 PB Separators H=100mm 4pz E1.2 3P 1SDA073877R1 E1.2 PB Separators H=100mm 6pz E1.2 4P 1SDA073878R1 E1.2 PB Separators H=200mm 4pz E1.2 3P 1SDA073879R1 E1.2 PB Separators H=200mm 6pz E1.2 4P 1SDA073880R1 9/60 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 60 15/04/2013 18:01:55 Accessories Mechanical interlock Cables for mechanical interlock [Group 1] Size Type Code E1.2..E6.2 Type A horizontal 1SDA073881R1 E2.2..E6.2 Type B,C,D horizontal 1SDA073882R1 E1.2..E6.2 Type A vertical 1SDA073885R1 E2.2..E6.2 Type B,C,D vertical 1SDA073886R1 Order one type of cable for each interlock. The cable must be ordered on the fixed circuit-breaker or on the fixed part of withdrawable circuit-breaker. Lever for mechanical interlock of fixed circuit-breaker or mobile part [Group 2] Size Type 3 Poles 4 Poles Code Code E2.2 Lever for mechanical interlock 1SDA073889R1 1SDA073889R1 E4.2 Lever for mechanical interlock 1SDA073890R1 1SDA073890R1 E6.2 Lever for mechanical interlock 1SDA073891R1 1SDA073892R1 The lever for mechanical interlock is not required for E1.2 Support for mechanical interlock of fixed circuit-breaker [Group 3] Size Type Code E1.2 Type A 1SDA073893R1 E1.2 Type A - Installed on bottom plate 1SDA073894R1 E2.2 … E6.2 Type A / B / D 1SDA073895R1 E2.2 … E6.2 Type C 1SDA073897R1 Support for mechanical interlock of fixed part [Group 4] Size Type Code E1.2 Type A 1SDA073896R1 E2.2 … E6.2 Type A / B / D 1SDA073895R1 E2.2 … E6.2 Type C 1SDA073897R1 9 Automatic transfer switch Size Type Code E1.2..E6.2 ATS021 1SDA065523R1 E1.2..E6.2 ATS022 1SDA065524R1 ABB Catalogue | 1SDC200023D0201 | 9/61 Emax2_cap09.indd 61 15/04/2013 18:01:56 1SDC200476F001 1SDC200475F001 1SDC200480F001 1SDC200466F001 1SDC200446F001 Accessories Ekip modules Ekip electrical trip units - loose supply Size Type Code E1.2..E6.2 Ekip Dip LI 1SDA074194R1 E1.2..E6.2 Ekip Dip LSI 1SDA074195R1 E1.2..E6.2 Ekip Dip LSIG 1SDA074196R1 E1.2..E6.2 Ekip Touch LI 1SDA074197R1 E1.2..E6.2 Ekip Touch LSI 1SDA074198R1 E1.2..E6.2 Ekip Touch LSIG 1SDA074199R1 E1.2..E6.2 Ekip G Touch LSIG 1SDA074200R1 E1.2..E6.2 Ekip Hi-Touch LSI 1SDA074201R1 E1.2..E6.2 Ekip Hi-Touch LSIG 1SDA074202R1 E1.2..E6.2 Ekip G Hi-Touch LSIG 1SDA074203R1 E1.2..E6.2 Ekip LCD LI 1SDA074204R1 E1.2..E6.2 Ekip LCD LSI 1SDA074205R1 E1.2..E6.2 Ekip LCD LSIG 1SDA074206R1 E1.2..E6.2 Ekip G LCD LSIG 1SDA074207R1 E1.2..E6.2 Ekip Hi-LCD LSI 1SDA074208R1 E1.2..E6.2 Ekip Hi-LCD LSIG 1SDA074209R1 E1.2..E6.2 Ekip G Hi-LCD LSIG 1SDA074210R1 E1.2..E6.2 Battery for Ekip trip units 1SDA074193R1 Options for Ekip electrical trip units 9 Size Type Code E1.2..E6.2 Ekip LCD Installed 1SDA074211R1 E1.2..E6.2 Ekip Power Controller 1SDA074212R1 E1.2..E6.2 Upper internal installed voltage outlets 1SDA074216R1 E1.2..E6.2 External installed voltage outlets 1SDA074217R1 E1.2..E6.2 Arrangement for cables with lower internal voltage outlets 1SDA074213R1 E1.2..E6.2 Arrangement for cables with upper internal voltage outlets 1SDA074214R1 E1.2..E6.2 Arrangement for cables with external voltage outlets 1SDA074215R1 1SDC200541F001 1SDC200540F001 1SDC200539F001 Power Supply modules Size Type Code E1.2..E6.2 Ekip Supply 110-240V AC/DC 1SDA074172R1 E1.2..E6.2 Ekip Supply 24-48V DC 1SDA074173R1 Connectivity modules Size Type Code E1.2..E6.2 Ekip Com Modbus RS-485 1SDA074150R1 E1.2..E6.2 Ekip Com Modbus TCP 1SDA074151R1 E1.2..E6.2 Ekip Com Profibus 1SDA074152R1 E1.2..E6.2 Ekip Com Profinet 1SDA074153R1 E1.2..E6.2 Ekip Com DeviceNet 1SDA074154R1 E1.2..E6.2 Ekip Com EtherNet/IP 1SDA074155R1 E1.2..E6.2 Ekip Com IEC61850 1SDA074156R1 E1.2..E6.2 Ekip Com R Modbus RS-485 1SDA074157R1 E1.2..E6.2 Ekip Com R Modbus TCP 1SDA074158R1 E1.2..E6.2 Ekip Com R Profibus 1SDA074159R1 E1.2..E6.2 Ekip Com R Profinet 1SDA074160R1 E1.2..E6.2 Ekip Com R DeviceNet 1SDA074161R1 E1.2..E6.2 Ekip Com R EtherNet/IP 1SDA074162R1 E1.2..E6.2 Ekip Link 1SDA074163R1 E1.2..E6.2 Ekip Bluetooth 1SDA074164R1 E1.2..E6.2 Ekip Com GPRS-M 1SDA074165R1 E1.2..E6.2 Ekip Com Actuator 1SDA074166R1 9/62 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 62 15/04/2013 18:01:58 1SDC200544F001 Signalling modules Size Type Code E1.2..E6.2 Ekip 2K-1 1SDA074167R1 E1.2..E6.2 Ekip 2K-2 1SDA074168R1 E1.2..E6.2 Ekip 2K-3 1SDA074169R1 E2.2..E6.2 Ekip 4K 1SDA074170R1 E1.2..E6.2 Ekip 10K 1SDA074171R1 1SDC200548F001 Measuring and protection modules Size Type Code E1.2 Ekip Measuring 1SDA074184R1 E1.2 Ekip Measuring Pro 1SDA074185R1 E2.2 Ekip Measuring 1SDA074186R1 E2.2 Ekip Measuring Pro 1SDA074187R1 E4.2 Ekip Measuring 1SDA074188R1 E4.2 Ekip Measuring Pro 1SDA074189R1 E6.2 Ekip Measuring 1SDA074190R1 E6.2 Ekip Measuring Pro 1SDA074191R1 E1.2..E6.2 Ekip Synchrocheck 1SDA074183R1 E2.2..E6.2 Ekip Fan 24V DC 1SDA074174R1 E2.2 Fan module for three-pole circuit-breaker 1SDA074176R1 E2.2 Fan module for four-pole circuit-breaker 1SDA074177R1 E4.2 Fan module for three-pole circuit-breaker 1SDA074178R1 E4.2 Fan module for four-pole circuit-breaker 1SDA074179R1 E6.2 Fan module for three-pole circuit-breaker 1SDA074180R1 E6.2 Fan module for four-pole circuit-breaker 1SDA074181R1 E6.2 Fan module for four-pole circuit-breaker with full size neutral 1SDA074182R1 9 1SDC200559F001 1SDC200558F001 Displaying and supervision systems Size Type Code E1.2..E6.2 Ekip Multimeter Display on front of switchgear 1SDA074192R1 E1.2..E6.2 Ekip Control Panel for 10 circuit-breakers 1SDA074311R1 E1.2..E6.2 Ekip control panel for 30 circuit-breakers 1SDA074312R1 E1.2..E6.2 Ekip Control Panel license extension to 30 circuit-breakers 1SDA074313R1 E1.2..E6.2 Ekip Control Panel alarm dispatcher option 1SDA074314R1 E1.2..E6.2 Ekip Control Panel option 5 eccess web client 1SDA074315R1 E1.2..E6.2 Ekip View Software for 30 circuit-breakers 1SDA074298R1 E1.2..E6.2 Ekip View software for 60 circuit-breakers 1SDA074299R1 E1.2..E6.2 Ekip View software for unlimited circuit-breakers 1SDA074300R1 E1.2..E6.2 Ekip View license extension to 60 circuit-breakers 1SDA074301R1 E1.2..E6.2 Ekip View license extension for an unlimited number of circuit-breakers 1SDA074302R1 E1.2..E6.2 Ekip View alarm dispatcher option for 30 circuit-breakers 1SDA074303R1 E1.2..E6.2 Ekip View alarm dispatcher option for 60 circuit-breakers 1SDA074304R1 E1.2..E6.2 Ekip View alarm dispatcher option for an unlimited number of circuit-breakers 1SDA074305R1 E1.2..E6.2 Ekip View 5 web access client option license of 30 circuit-breakers 1SDA074306R1 E1.2..E6.2 Ekip View 5 web access client option license of 60 circuit-breakers 1SDA074307R1 E1.2..E6.2 Ekip View 5 web access client option license for an unlimited number of circuit-breakers 1SDA074308R1 E1.2..E6.2 Ekip View redundancy option 1SDA074309R1 E1.2..E6.2 Ekip View OPC server-client option 1SDA074310R1 ABB Catalogue | 1SDC200023D0201 | 9/63 Emax2_cap09.indd 63 15/04/2013 18:01:59 1SDC200554F001 Accessories Ekip modules 9 Rating plug for Ekip trip units Size Type Code (loose supply) Code (installed) E1.2..E6.2 Rating Plug 100A 1SDA074218R1 1SDA074258R1 E1.2..E6.2 Rating Plug 200A 1SDA074219R1 1SDA074259R1 E1.2..E6.2 Rating Plug 250A 1SDA074220R1 1SDA074260R1 E1.2..E6.2 Rating Plug 400A 1SDA074221R1 1SDA074261R1 E1.2..E6.2 Rating Plug 630A 1SDA074222R1 1SDA074262R1 E1.2..E6.2 Rating Plug 800A 1SDA074223R1 1SDA074263R1 E1.2..E6.2 Rating Plug 1000A 1SDA074224R1 1SDA074264R1 E1.2..E6.2 Rating Plug 1250A 1SDA074225R1 1SDA074265R1 E1.2..E6.2 Rating Plug 1600A 1SDA074226R1 1SDA074266R1 E1.2..E6.2 Rating Plug 2000A 1SDA074227R1 1SDA074267R1 E1.2..E6.2 Rating Plug 2500A 1SDA074228R1 1SDA074268R1 E1.2..E6.2 Rating Plug 3200A 1SDA074229R1 1SDA074269R1 E1.2..E6.2 Rating Plug 4000A 1SDA074230R1 1SDA074270R1 E1.2..E6.2 Rating Plug 5000A 1SDA074231R1 1SDA074271R1 E1.2..E6.2 Rating Plug 6300A 1SDA074232R1 1SDA074272R1 E1.2..E6.2 Rating Plug 100A L OFF 1SDA074233R1 1SDA074273R1 E1.2..E6.2 Rating Plug 200A L OFF 1SDA074234R1 1SDA074274R1 E1.2..E6.2 Rating Plug 250A L OFF 1SDA074235R1 1SDA074275R1 E1.2..E6.2 Rating Plug 400A L OFF 1SDA074236R1 1SDA074276R1 E1.2..E6.2 Rating Plug 630A L OFF 1SDA074237R1 1SDA074277R1 E1.2..E6.2 Rating Plug 800A L OFF 1SDA074238R1 1SDA074278R1 E1.2..E6.2 Rating Plug 1000A L OFF 1SDA074239R1 1SDA074279R1 E1.2..E6.2 Rating Plug 1250A L OFF 1SDA074240R1 1SDA074280R1 E1.2..E6.2 Rating Plug 1600A L OFF 1SDA074241R1 1SDA074281R1 E1.2..E6.2 Rating Plug 2000A L OFF 1SDA074242R1 1SDA074282R1 E1.2..E6.2 Rating Plug 2500A L OFF 1SDA074243R1 1SDA074283R1 E1.2..E6.2 Rating Plug 3200A L OFF 1SDA074244R1 1SDA074284R1 E1.2..E6.2 Rating Plug 4000A L OFF 1SDA074245R1 1SDA074285R1 E1.2..E6.2 Rating Plug 5000A L OFF 1SDA074246R1 1SDA074286R1 E1.2..E6.2 Rating Plug 6300A L OFF 1SDA074247R1 1SDA074287R1 E1.2..E6.2 Rating Plug RC 100A 1SDA074248R1 1SDA074288R1 E1.2..E6.2 Rating Plug RC 200A 1SDA074249R1 1SDA074289R1 E1.2..E6.2 Rating Plug RC 250A 1SDA074250R1 1SDA074290R1 E1.2..E6.2 Rating Plug RC 400A 1SDA074251R1 1SDA074291R1 E1.2..E6.2 Rating Plug RC 630A 1SDA074252R1 1SDA074292R1 E1.2..E6.2 Rating Plug RC 800A 1SDA074253R1 1SDA074293R1 E1.2..E6.2 Rating Plug RC 1250A 1SDA074254R1 1SDA074294R1 E1.2..E6.2 Rating Plug RC 2000A 1SDA074255R1 1SDA074295R1 E1.2..E6.2 Rating Plug RC 3200A 1SDA074256R1 1SDA074296R1 E1.2..E6.2 Rating Plug RC 4000A 1SDA074257R1 1SDA074297R1 9/64 | 1SDC200023D0201 | ABB Catalogue Emax2_cap09.indd 64 15/04/2013 18:02:00 Accessories Terminals Kit for terminals - installed for fixed circuit-breaker Size Rear orientable terminal - HR VR Horizontal rear spread terminal - SHR Vertical rear spread terminal - SVR Extended front terminal - EF Front terminal - F Front spread terminal - ES Version Iu max Type 3 Poles 4 Poles Code Code E1.2 F 1600 Kit EF Upper 1SDA073963R1 1SDA073964R1 E1.2 F 1600 Kit EF Lower 1SDA073965R1 1SDA073966R1 E1.2 F 1600 Kit ES Upper 1SDA073975R1 1SDA073976R1 E1.2 F 1600 Kit ES Lower 1SDA073977R1 1SDA073978R1 E1.2 F 1600 Kit HR Upper 1SDA073981R1 1SDA073982R1 E1.2 F 1600 Kit HR Lower 1SDA073983R1 1SDA073984R1 E1.2 F 1600 Kit VR Upper 1SDA073985R1 1SDA073986R1 E1.2 F 1600 Kit VR Lower 1SDA073987R1 1SDA073988R1 E1.2 F 1600 Kit FC CuAl 4x240 mm2 Upper 1SDA073997R1 1SDA073998R1 E1.2 F 1600 Kit FC CuAl 4x240 mm2 Lower 1SDA073999R1 1SDA074000R1 E2.2 F 2000 Kit VR Upper 1SDA074003R1 1SDA074004R1 E2.2 F 2000 Kit VR Lower 1SDA074005R1 1SDA074006R1 E2.2 F 2500 Kit VR Upper 1SDA074009R1 1SDA074010R1 E2.2 F 2500 Kit VR Lower 1SDA074011R1 1SDA074012R1 E2.2 F 2000 Kit SHR Upper 1SDA074045R1 1SDA074046R1 E2.2 F 2000 Kit SHR Lower 1SDA074047R1 1SDA074048R1 E2.2 F 2500 Kit SHR Upper 1SDA074051R1 1SDA074052R1 E2.2 F 2500 Kit SHR Lower 1SDA074053R1 1SDA074054R1 E2.2 F 2000 Kit SVR Upper 1SDA074057R1 1SDA074058R1 E2.2 F 2000 Kit SVR Lower 1SDA074059R1 1SDA074060R1 E2.2 F 2500 Kit SVR Upper 1SDA074063R1 1SDA074064R1 E2.2 F 2500 Kit SVR Lower 1SDA074065R1 1SDA074066R1 E2.2 F 2500 Kit F Upper 1SDA074118R1 1SDA074119R1 E2.2 F 2500 Kit F Lower 1SDA074120R1 1SDA074121R1 E4.2 F 3200 Kit VR Upper 1SDA074015R1 1SDA074016R1 E4.2 F 3200 Kit VR Lower 1SDA074017R1 1SDA074018R1 E4.2 F 4000 Kit VR Upper 1SDA074021R1 1SDA074022R1 E4.2 F 4000 Kit VR Lower 1SDA074023R1 1SDA074024R1 E4.2 F 4000 Kit F Upper 1SDA074126R1 1SDA074127R1 E4.2 F 4000 Kit F Lower 1SDA074128R1 1SDA074129R1 E6.2 F 5000 Kit VR Upper 1SDA074027R1 1SDA074028R1 E6.2 F 5000 Kit VR Lower 1SDA074030R1 E6.2/f F 5000 Kit VR Upper E6.2/f F 5000 Kit VR Lower E6.2 F 6300 Kit F Upper 1SDA074134R1 E6.2 F 6300 Kit F Lower 1SDA074137R1 E6.2/f F 6300 Kit F Upper 1SDA074136R1 E6.2/f F 6300 Kit F Lower 1SDA074139R1 E6.2 F 6300 Kit VR Upper 1SDA074036R1 E6.2 F 6300 Kit VR Lower 1SDA074039R1 E6.2/f F 6300 Kit VR Upper 1SDA074038R1 E6.2/f F 6300 Kit VR Lower 1SDA074041R1 9 1SDA074031R1 1SDA074029R1 1SDA074032R1 1SDA074135R1 1SDA074138R1 1SDA074037R1 1SDA074040R1 Terminal for cable FcCuAl 4x240mm2 - Fc CuAl ABB Catalogue | 1SDC200023D0201 | 9/65 Emax2_cap09.indd 65 15/04/2013 18:02:01 Accessories Terminals Kit for terminals - installed for fixed part of withdrawable circuit-breaker Size Rear orientable terminal - HR VR Horizontal rear terminal - SHR Vertical rear spread terminal - SVR 9 Front terminal - F Extended front terminal - EF Front spread terminal - ES Terminal for cable FcCuAl 4x240mm2 - Fc CuAl Version Iu max Type 3 Poles 4 Poles Code Code E1.2 W 1600 Kit EF Upper 1SDA073939R1 1SDA073940R1 E1.2 W 1600 Kit EF Lower 1SDA073941R1 1SDA073942R1 E1.2 W 1600 Kit VR Upper 1SDA073945R1 1SDA073946R1 E1.2 W 1600 Kit VR Lower 1SDA073947R1 1SDA073948R1 E1.2 W 1600 Kit ES Upper * 1SDA073951R1 1SDA073952R1 E1.2 W 1600 Kit ES Lower * 1SDA073953R1 1SDA073954R1 E1.2 W 1600 Kit SHR Upper 1SDA073957R1 1SDA073958R1 E1.2 W 1600 Kit SHR Lower 1SDA073959R1 1SDA073960R1 E1.2 W 1600 Kit FC CuAl 4x240 mm2 Upper 1SDA073991R1 1SDA073993R1 E1.2 W 1600 Kit FC CuAl 4x240 mm2 Lower 1SDA073992R1 1SDA073994R1 E2.2 W 2000 Kit VR Upper 1SDA074577R1 1SDA074578R1 E2.2 W 2000 Kit VR Lower 1SDA074579R1 1SDA074580R1 E2.2 W 2500 Kit VR Upper 1SDA074581R1 1SDA074582R1 E2.2 W 2500 Kit VR Lower 1SDA074583R1 1SDA074584R1 E2.2 W 2000 Kit SHR Upper 1SDA074585R1 1SDA074586R1 E2.2 W 2000 Kit SHR Lower 1SDA074587R1 1SDA074588R1 E2.2 W 2500 Kit SHR Upper 1SDA074589R1 1SDA074590R1 E2.2 W 2500 Kit SHR Lower 1SDA074591R1 1SDA074592R1 E2.2 W 2000 Kit SVR Upper 1SDA074593R1 1SDA074594R1 E2.2 W 2000 Kit SVR Lower 1SDA074595R1 1SDA074596R1 E2.2 W 2500 Kit SVR Upper 1SDA074597R1 1SDA074598R1 E2.2 W 2500 Kit SVR Lower 1SDA074599R1 1SDA074600R1 E2.2 W 2500 Kit FL Upper 1SDA074069R1 1SDA074070R1 E2.2 W 2500 Kit FL Lower 1SDA074071R1 1SDA074072R1 E2.2 W 2500 Kit F Upper 1SDA074090R1 1SDA074091R1 E2.2 W 2500 Kit F Lower 1SDA074092R1 1SDA074093R1 E4.2 W 3200 Kit VR Upper 1SDA074601R1 1SDA074602R1 E4.2 W 3200 Kit VR Lower 1SDA074603R1 1SDA074604R1 E4.2 W 4000 Kit VR Upper 1SDA074605R1 1SDA074606R1 E4.2 W 4000 Kit VR Lower 1SDA074607R1 1SDA074608R1 Kit F Upper 1SDA074098R1 1SDA074099R1 E4.2 W 4000 E4.2 W 4000 Kit F Lower 1SDA074100R1 1SDA074101R1 E4.2 W 4000 Kit FL Upper 1SDA074075R1 1SDA074076R1 E4.2 W 4000 Kit FL Lower 1SDA074077R1 1SDA074078R1 E6.2 W 5000 Kit VR Upper 1SDA074609R1 1SDA074610R1 1SDA074612R1 E6.2 W 5000 Kit VR Lower E6.2/f W 5000 Kit VR Upper E6.2/f W 5000 Kit VR Lower E6.2 W 6300 Kit VR Upper 1SDA074615R1 1SDA074618R1 E6.2 W 6300 Kit VR Lower E6.2/f W 6300 Kit VR Upper 1SDA074614R1 E6.2/f W 6300 Kit VR Lower W 6300 Kit F Upper 1SDA074106R1 1SDA074109R1 E6.2 W 6300 Kit F Lower W 6300 Kit F Upper 1SDA074616R1 1SDA074619R1 1SDA074617R1 E6.2 E6.2/f 1SDA074613R1 1SDA074611R1 1SDA074620R1 1SDA074107R1 1SDA074110R1 1SDA074108R1 E6.2/f W 6300 Kit F Lower E6.2 W 6300 Kit FL Upper 1SDA074081R1 1SDA074084R1 1SDA074111R1 1SDA074082R1 E6.2 W 6300 Kit FL Lower E6.2/f W 6300 Kit FL Upper 1SDA074083R1 E6.2/f W 6300 Kit FL Lower 1SDA074086R1 * can be ordered only if the fixed part has EF terminals. 9/66 | 1SDC200023D0201 | ABB Catalogue 1SDA074085R1 Kit for terminals - loose supply for fixed circuit-breaker Size Rear orientable terminal - HR VR Horizontal rear spread terminal - SHR Vertical rear spread terminal - SVR Extended front terminal - EF Version Iu max Type 3 Poles 4 Poles Code Code E1.2 F 1600 Kit EF 1SDA073967R1 1SDA073968R1 E1.2 F 1600 Kit F 1SDA073973R1 1SDA073974R1 E1.2 F 1600 Kit ES 1SDA073979R1 1SDA073980R1 E1.2 F 1600 Kit Adjustable HR/VR 1SDA073989R1 1SDA073990R1 E1.2 F 1600 Kit FC CuAl 4x240 mm2 1SDA074001R1 1SDA074002R1 E2.2 F 2000 Kit Adjustable HR/VR 1SDA074007R1 1SDA074008R1 E2.2 F 2500 Kit Adjustable HR/VR 1SDA074013R1 1SDA074014R1 E2.2 F 2000 Kit SHR 1SDA074049R1 1SDA074050R1 E2.2 F 2500 Kit SHR 1SDA074055R1 1SDA074056R1 E2.2 F 2000 Kit SVR 1SDA074061R1 1SDA074062R1 E2.2 F 2500 Kit SVR 1SDA074067R1 1SDA074068R1 E4.2 F 3200 Kit Adjustable HR/VR 1SDA074019R1 1SDA074020R1 E4.2 F 4000 Kit Adjustable HR/VR 1SDA074025R1 1SDA074026R1 E4.2 F 4000 Kit F Upper 1SDA074130R1 1SDA074131R1 E4.2 F 4000 Kit F Lower 1SDA074132R1 1SDA074133R1 E6.2 F 5000 Kit Adjustable HR/VR 1SDA074033R1 1SDA074034R1 E6.2/f F 5000 Kit Adjustable HR/VR E6.2 F 6300 Kit Adjustable HR/VR E6.2/f F 6300 Kit Adjustable HR/VR E6.2 F 6300 Kit F Upper 1SDA074140R1 1SDA074141R1 E6.2 F 6300 Kit F Lower 1SDA074143R1 1SDA074144R1 E6.2/f F 6300 Kit F Upper 1SDA074142R1 E6.2/f F 6300 Kit F Lower 1SDA074145R1 1SDA074035R1 1SDA074042R1 1SDA074043R1 1SDA074044R1 9 Adapter plate for terminals - loose supply for fixed circuit-breaker Size Version Iu Type 3 Poles 4 Poles Code Code E2.2 F 2500 Kit Terminal Adapter Plate 1SDA074146R1 1SDA074147R1 E4.2 F 4000 Kit Terminal Adapter Plate 1SDA074148R1 1SDA074149R1 Front terminal - F Front spread terminal - ES Terminal for cable FcCuAl 4x240mm2 - Fc CuAl ABB Catalogue | 1SDC200023D0201 | 9/67 Emax2_cap09.indd 67 15/04/2013 18:02:05 Accessories Terminals Kit for terminals - loose supply for fixed part of withdrawable circuit-breaker Size Rear orientable terminal - HR VR Horizontal rear terminal - SHR Vertical rear spread terminal - SVR 9 Front terminal - F Version Iu max Type 3 Poles 4 Poles Code Code E1.2 W 1600 Kit EF 1SDA073943R1 1SDA073944R1 E1.2 W 1600 Kit Adjustable HR/VR 1SDA073949R1 1SDA073950R1 E1.2 W 1600 Kit ES 1SDA073955R1 1SDA073956R1 E1.2 W 1600 Kit SHR 1SDA073961R1 1SDA073962R1 E1.2 W 1600 Kit FC CuAl 4x240 mm2 1SDA073995R1 1SDA073996R1 E2.2 W 2000 Kit Adjustable HR/VR 1SDA074007R1 1SDA074008R1 E2.2 W 2500 Kit Adjustable HR/VR 1SDA074013R1 1SDA074014R1 E2.2 W 2000 Kit SHR 1SDA074049R1 1SDA074050R1 E2.2 W 2500 Kit SHR 1SDA074055R1 1SDA074056R1 E2.2 W 2000 Kit SVR 1SDA074061R1 1SDA074062R1 E2.2 W 2500 Kit SVR 1SDA074067R1 1SDA074068R1 E2.2 W 2500 Kit FL 1SDA074073R1 1SDA074074R1 Kit Adjustable HR/VR 1SDA074019R1 1SDA074020R1 E4.2 W 3200 E4.2 W 4000 Kit Adjustable HR/VR 1SDA074025R1 1SDA074026R1 E4.2 W 4000 Kit F Upper 1SDA074102R1 1SDA074103R1 E4.2 W 4000 Kit F Lower 1SDA074104R1 1SDA074105R1 E4.2 W 4000 Kit FL 1SDA074079R1 1SDA074080R1 1SDA074033R1 E6.2 W 5000 Kit Adjustable HR/VR E6.2/f W 5000 Kit Adjustable HR/VR E6.2 W 6300 Kit Adjustable HR/VR E6.2/f W 6300 Kit Adjustable HR/VR 1SDA074042R1 E6.2 W 6300 Kit F Upper 1SDA074112R1 W 6300 Kit F Lower 1SDA074115R1 E6.2/f W 6300 Kit F Upper E6.2/f W 6300 Kit F Lower E6.2 W 6300 Kit FL E6.2/f W 6300 Kit FL Front spread terminal - ES Terminal for cable FcCuAl 4x240mm2 - Fc CuAl 9/68 | 1SDC200023D0201 | ABB Catalogue 1SDA074043R1 1SDA074044R1 E6.2 Extended front terminal - EF 1SDA074034R1 1SDA074035R1 1SDA074113R1 1SDA074116R1 1SDA074114R1 1SDA074117R1 1SDA074087R1 1SDA074088R1 1SDA074089R1 www.abb.com The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2013 ABB. All rights reserved. 1SDC200023D0201 - 03/2013 - 6.000 - CAL - Preliminary ABB SACE A division of ABB S.p.A. L.V. Breakers Via Baioni, 35 24123 Bergamo Phone: +39 035 395.111 Fax: +39 035 395.306-433 SACE Emax 2. New low voltage air circuit-breakers Contact us Technical catalogue - Edition 03.2013 - Preliminary Technical cat. | Ed. 03.2013 | Preliminary SACE Emax 2 New low voltage air circuit-breakers