Features Applications ■ Self-resetting sneak current protection with ■ Telecommunications Bourns® TBU® Electronic Current Limiter (ECL) for overcurrent and overvoltage protection Fast-acting High DC voltage Stable breakdown throughout life High bandwidth performance ■ Data communications ■ ■ ■ ■ 2469 Series 5-Pin TBU® Surge Protector The Bourns® 2469 Series Surge Protector Module incorporates Bourns® TBU® Electronic Current Limiters. Bourns® TBU® ECL devices are electronic circuit protectors that provide high-speed overcurrent protection. The Model 2469 is designed to fail “open” should a power cross or high current event occur. Characteristics Test Methods per UL 497, CSA C22.2, Telcordia GR 974 and 1361. DC Breakdown ........................................................................................................................................................700 V typ. 670 V min. 800 V max. Insulation Resistance ...............................................................100 Vdc .................................................................> 100 MΩ Voltage Control (Vop/Vout) ........................................................1 kV/µs @ 25°C.....................................................670/800 V Current Control (Iop/Iout) ..........................................................25°C ......................................................................180/360 mA Line Series Resistance ............................................................................................................................................24 Ω typ. Line Resistance Balance .........................................................................................................................................0.5 Ω typ. / 1.0 Ω max. Capacitance Tip to Ring ..........................................................1 MHz ....................................................................30 pF typ. Capacitance Tip or Ring to Ground .........................................1 MHz ....................................................................30 pF typ. Time-to-protect (tprotect) ...........................................................................................................................................10 µs Impulse Life Characteristics (ELTGS) .....................................10 A 10/1000 µs ....................................................Unlimited 40 A, 10/1000 µs ...................................................Unlimited 2.5 kA, 8/20 µs (ELTGS 5 kA total) .......................1 operation1 AC Life Characteristics (ELTGS) ..............................................600 Vrms 1 A 1 second fault..................................> 60 operations 600 Vrms 5 A 1 second fault..................................1 operation1 Absolute Maximum Ratings Continuous AC Fault Voltage (Vac) ....................................................................................................................470 Vrms / 670 Vpeak Impulse Discharge Current (Ifault) .......................................8/20 µs ELTGS ......................................................250 A Storage and Operating Temperature .......................................................................................................................-55 to +85 °C Notes: 1 Fuse will fail open and disconnect from circuit. Definitions: Vac ..................Maximum blocking voltage for continuous AC faults; module shunts voltages greater than these ratings. Ifault ................Maximum current-carrying capability of the module . Vimpulse ...........Maximum protection voltage for impulse faults (Vimpulse = Ifault X Rload). Vop ..................Maximum voltage on the input of the device that will not cause voltage limiting. Vout .................Maximum voltage on the output of the device under any condition. Iop ...................Maximum current through the device that will not cause current blocking (at 85 °C, use 0.80 derating factor, linear throughout temperature range. Iout ...................Maximum current through the device under any condition (at 85 °C, use 0.80 derating factor, linear throughout temperature range. tprotect .............Maximum time for the device to go from normal operating state to protected state. ELTGS ............Each Line to Ground Simultanuously. Line resistance balance ............Maximum difference in series resistance for tip/ring pair (line-line). Consult factory for alternate specification values. “TBU” is a registered trademark of Bourns, Inc. in the United States and other countries (in Japan, use”Bourns® TBU™ HSP”. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 2469 Series 5-Pin TBU® Surge Protector Product Dimensions 13.0 (0.51) 64.5 (2.54) 5.7 (0.223) 19.1 (0.75) 11.2 (0.44) 5.6 (0.22) 52.6 (2.07) DIMENSIONS: 6.1 (0.24) MILLIMETERS (INCHES) How to Order Schematic 2469 - 4 x(x) - x - x(x) Outside Plant Tip Equipment Tip Ground Outside Plant Ring Equipment Ring Model Number Designator Housing Color/Circuit Type 1 = Black 3 = Red 6 = Blue 7 = Violet 9 = Orange 10 = Yellow Pin Plating G = Gold-plated N = Tin-plated (GND pin is tin-plated on all models) Special Options S = Sealed Case ST = Sealed Case and Test Points T = Test Points Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com REV. B 04/13 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.