2469

Features
Applications
■ Self-resetting sneak current protection with
■ Telecommunications
Bourns® TBU® Electronic Current Limiter
(ECL) for overcurrent and overvoltage
protection
Fast-acting
High DC voltage
Stable breakdown throughout life
High bandwidth performance
■ Data communications
■
■
■
■
2469 Series 5-Pin TBU® Surge Protector
The Bourns® 2469 Series Surge Protector Module incorporates Bourns® TBU® Electronic Current Limiters. Bourns® TBU® ECL devices
are electronic circuit protectors that provide high-speed overcurrent protection. The Model 2469 is designed to fail “open” should a
power cross or high current event occur.
Characteristics
Test Methods per UL 497, CSA C22.2, Telcordia GR 974 and 1361.
DC Breakdown ........................................................................................................................................................700 V typ.
670 V min.
800 V max.
Insulation Resistance ...............................................................100 Vdc .................................................................> 100 MΩ
Voltage Control (Vop/Vout) ........................................................1 kV/µs @ 25°C.....................................................670/800 V
Current Control (Iop/Iout) ..........................................................25°C ......................................................................180/360 mA
Line Series Resistance ............................................................................................................................................24 Ω typ.
Line Resistance Balance .........................................................................................................................................0.5 Ω typ. / 1.0 Ω max.
Capacitance Tip to Ring ..........................................................1 MHz ....................................................................30 pF typ.
Capacitance Tip or Ring to Ground .........................................1 MHz ....................................................................30 pF typ.
Time-to-protect (tprotect) ...........................................................................................................................................10 µs
Impulse Life Characteristics (ELTGS) .....................................10 A 10/1000 µs ....................................................Unlimited
40 A, 10/1000 µs ...................................................Unlimited
2.5 kA, 8/20 µs (ELTGS 5 kA total) .......................1 operation1
AC Life Characteristics (ELTGS) ..............................................600 Vrms 1 A 1 second fault..................................> 60 operations
600 Vrms 5 A 1 second fault..................................1 operation1
Absolute Maximum Ratings
Continuous AC Fault Voltage (Vac) ....................................................................................................................470 Vrms / 670 Vpeak
Impulse Discharge Current (Ifault) .......................................8/20 µs ELTGS ......................................................250 A
Storage and Operating Temperature .......................................................................................................................-55 to +85 °C
Notes:
1
Fuse will fail open and disconnect from circuit.
Definitions:
Vac ..................Maximum blocking voltage for continuous AC faults; module shunts voltages greater than these ratings.
Ifault ................Maximum current-carrying capability of the module .
Vimpulse ...........Maximum protection voltage for impulse faults (Vimpulse = Ifault X Rload).
Vop ..................Maximum voltage on the input of the device that will not cause voltage limiting.
Vout .................Maximum voltage on the output of the device under any condition.
Iop ...................Maximum current through the device that will not cause current blocking (at 85 °C, use 0.80 derating factor, linear
throughout temperature range.
Iout ...................Maximum current through the device under any condition (at 85 °C, use 0.80 derating factor, linear throughout
temperature range.
tprotect .............Maximum time for the device to go from normal operating state to protected state.
ELTGS ............Each Line to Ground Simultanuously.
Line resistance
balance ............Maximum difference in series resistance for tip/ring pair (line-line).
Consult factory for alternate specification values.
“TBU” is a registered trademark of Bourns, Inc. in the United States and other countries (in Japan, use”Bourns® TBU™ HSP”.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
2469 Series 5-Pin TBU® Surge Protector
Product Dimensions
13.0
(0.51)
64.5
(2.54)
5.7
(0.223)
19.1
(0.75)
11.2
(0.44)
5.6
(0.22)
52.6
(2.07)
DIMENSIONS:
6.1
(0.24)
MILLIMETERS
(INCHES)
How to Order
Schematic
2469 - 4 x(x) - x - x(x)
Outside Plant Tip
Equipment Tip
Ground
Outside Plant Ring
Equipment Ring
Model Number Designator
Housing Color/Circuit Type
1 = Black
3 = Red
6 = Blue
7 = Violet
9 = Orange
10 = Yellow
Pin Plating
G = Gold-plated
N = Tin-plated (GND pin is tin-plated on all models)
Special Options
S = Sealed Case
ST = Sealed Case and Test Points
T = Test Points
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
REV. B 04/13
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.