Features
Applications
■ Surface Mount Device
Provides overcurrent protection in:
■ Customer Premise Equipment (CPE)
■ Central Office (CO)
■ Access/Outside Plant Equipment
*R
oH
S
■ Reduced footprint size
■ High voltage surge capabilities
■ Assists in meeting ITU K.20/K.21/K.45
specifications
■ RoHS compliant*
■ Agency recognition:
MF-SM013/250V - Telecom PTC Resettable Fuses
Electrical Characteristics
Model
Max.
Interrupt
Ratings
Volts
Amps
(V)
(A)
Max.
Max.
250
3.0
Max.
Operating
Voltage
Volts
MF-SM013/250V
60
Hold
Current
Amps
at 23 °C
IH
0.13
Initial
Resistance
Ohms
at 23 °C
Min.
4.0
Ohms
at 23 °C
Max.
7.0
One Hour
Post-Trip
Resistance
Ohms
at 23 °C
Max.
16.0
Tripped
Power
Dissipation
Watts
at 23 °C
Typ.
3.0
Environmental Characteristics
Operating Temperature......................................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................. 125 °C
Passive Aging ....................................................... +85 °C, 1000 hours ............................................... ±5 % typical resistance change
+60 °C, 1000 hours ............................................... ±5 % typical resistance change
Humidity Aging...................................................... +85 °C, 85 % R.H. 500 hours ............................... ±5 % typical resistance change
Thermal Shock ..................................................... MIL-STD-202F, Method 107G,.............................. ±10 % typical resistance change
+125 °C to -55 °C,10 times ................................... ±15 % typical resistance change
Solvent Resistance ............................................... MIL-STD-202, Method 215B ................................. No change
Lead Solerability ................................................... ANSI/J-STD-002
Flammability ......................................................... IEC 695-2-2 .......................................................... No Flame for 60 secs.
Vibration ............................................................... MIL-STD-883C, Method 2007.1, Condition A ....... No change
Test Procedures And Requirements For Model MF-SM013/250V Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech. ......................................................... Verify dimensions and materials ........................... Per MF physical description
Resistance ............................................................ In still air @ 23 °C ................................................. Rmin ≤ R ≤ Rmax
Time to Trip ........................................................... At specified current, Vmax, 23 °C ......................... T ≤ max. time to trip (seconds)
Hold Current ......................................................... 30 min. at Ihold ..................................................... No trip
Trip Cycle Life ....................................................... Vmax, Imax, 100 cycles ........................................ No arcing or burning
Trip Endurance ..................................................... Vmax, 48 hours..................................................... No arcing or burning
Solderability .......................................................... MIL-STD-202F, Method 208F ............................... 95 % min. coverage
UL File Number ..................................................... E174545
TÜV File Number .................................................. R2057213
Thermal Derating Chart - Ihold/Itrip (Amps)
Model
MF-SM013/250V
-40 °C
0.21 / 0.42
-20 °C
0.18 / 0.37
0 °C
0.16 / 0.31
Ambient Operating Temperature
23 °C
40 °C
50 °C
0.13 / 0.26 0.10 / 0.23 0.09 / 0.18
60 °C
0.08 / 0.15
70 °C
0.07 / 0.12
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
85 °C
0.05 / 0.10
MF-SM013/250V - Telecom PTC Resettable Fuses
Recommended Pad Layout
Product Dimensions
6.6
MAX.
(.260)
2.29
(.090)
7.4
(.291)
MAX.
2.29
(.090)
2.41
(.095)
3.43
(.135)
2.41
(.095)
6.35
(.250)
3.2
(.126)
MAX.
1.94
(.076)
DIMENSIONS:
MM
(INCHES)
Terminal material:
Tin-plated brass
Packaging:
TAPE & REEL: 1000 pcs. per reel
Solder Reflow Recommendations
300
Preheating
Soldering
Cooling
Temperature (°C)
250
200
150
100
Solder reflow
•
Recommended reflow methods: IR, vapor phase oven, hot air oven.
•
Devices are not designed to be wave soldered to the bottom side of the
board.
•
Gluing the devices is not recommended.
•
Recommended maximum paste thickness is 0.25 mm (.010 inch).
•
Devices can be cleaned using standard industry methods and solvents.
Note:
•
50
If reflow temperatures exceed the recommended profile, devices may not
meet the performance requirements.
Rework
0
160–220
10–20
120
•
A device should not be reworked.
Time (seconds)
Storage Recommendations
The recommended long term storage conditions for Multifuse® Polymer PTC devices are 40 °C maximum and 70 % RH maximum. All devices should remain in the original sealed packaging prior to use. Devices may not conform with data sheet specifications if these storage recommendations are exceeded. Devices stored in this manner
have an indefinite shelf life.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-SM013/250V - Telecom PTC Resettable Fuses
Typical Time to Trip at 23 ˚C
Typical Part Marking
Represents total content. Layout may vary.
20
10
MANUFACTURER'S
TRADEMARK
Time to Trip (Seconds)
013V
4C
PART
IDENTIFICATION
DATE CODE:
WEEK 3 OF 2004 = 4C
WEEK 29 OF 2004 = C4
1
How to Order
MF - SM 013/250V - 2
0.1
0.01
0.1
1
Fault Current (Amps)
5
Multifuse®
Product Designator
Series
SM = Surface Mount
Component
Hold Current, Ihold
013 = 0.13 Amps
Max. Interrupt Voltage, V
250 = 250 Volts
Telecom Options
V = Vertical Profile
(Surface Mount Products Only)
Packaging Options
- 0 = Bulk Packaging
- 2 = Tape and Reel*
*Packaged per EIA486-B
MF-SM013/250V, REV. F, 08/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-SM/250V Series Tape and Reel Specifications
MF-SM013/250V
per EIA 481-1
Tape Dimensions
W
16.0 ± 0.3
(0.630 ± 0.012)
P0
4.0 ± 0.1
(0.157 ± 0.004)
8.0 ± 0.1
(0.315 ± 0.004)
2.0 ± 0.1
(0.079 ± 0.004)
3.3 ± 0.1
(0.130 ± 0.004)
6.66 ± 0.1
(0.262 ± 0.004)
7.2
(0.283)
1.5 ± 0.1
(0.059 ± 0.004)
7.5 ± 0.1
(0.295 + 0.004)
1.75 ± 0.1
(0.069 ± 0.004)
P1
P2
A0
B0
B1 max.
D0
F
E1
14.25
(0.561)
0.45
(0.018)
0.1
(0.004)
E2 min.
T max.
T1 max.
7.0
(0.276)
390
(15.35)
160
(6.30)
K0
Leader min.
Trailer min.
Reel Dimensions
N min.
340
(13.39)
50
(1.97)
W1
16.4
(0.646)
W2 max.
22.4
(0.882)
A max.
MM
UNIT =
(INCHES)
P0
T
D0
P2
E1
W2(MEASURED
AT HUB)
COVER
TAPE
F
E2 W
B1
A
N(HUB DIA.)
B0
K0
T1
P1
A0
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
W1(MEASURED
AT HUB)