T PL IA N M CO Features Applications ■ Surface Mount Device Provides overcurrent protection in: ■ Customer Premise Equipment (CPE) ■ Central Office (CO) ■ Access/Outside Plant Equipment *R oH S ■ Reduced footprint size ■ High voltage surge capabilities ■ Assists in meeting ITU K.20/K.21/K.45 specifications ■ RoHS compliant* ■ Agency recognition: MF-SM013/250V - Telecom PTC Resettable Fuses Electrical Characteristics Model Max. Interrupt Ratings Volts Amps (V) (A) Max. Max. 250 3.0 Max. Operating Voltage Volts MF-SM013/250V 60 Hold Current Amps at 23 °C IH 0.13 Initial Resistance Ohms at 23 °C Min. 4.0 Ohms at 23 °C Max. 7.0 One Hour Post-Trip Resistance Ohms at 23 °C Max. 16.0 Tripped Power Dissipation Watts at 23 °C Typ. 3.0 Environmental Characteristics Operating Temperature......................................... -40 °C to +85 °C Maximum Device Surface Temperature in Tripped State ................................................. 125 °C Passive Aging ....................................................... +85 °C, 1000 hours ............................................... ±5 % typical resistance change +60 °C, 1000 hours ............................................... ±5 % typical resistance change Humidity Aging...................................................... +85 °C, 85 % R.H. 500 hours ............................... ±5 % typical resistance change Thermal Shock ..................................................... MIL-STD-202F, Method 107G,.............................. ±10 % typical resistance change +125 °C to -55 °C,10 times ................................... ±15 % typical resistance change Solvent Resistance ............................................... MIL-STD-202, Method 215B ................................. No change Lead Solerability ................................................... ANSI/J-STD-002 Flammability ......................................................... IEC 695-2-2 .......................................................... No Flame for 60 secs. Vibration ............................................................... MIL-STD-883C, Method 2007.1, Condition A ....... No change Test Procedures And Requirements For Model MF-SM013/250V Series Test Test Conditions Accept/Reject Criteria Visual/Mech. ......................................................... Verify dimensions and materials ........................... Per MF physical description Resistance ............................................................ In still air @ 23 °C ................................................. Rmin ≤ R ≤ Rmax Time to Trip ........................................................... At specified current, Vmax, 23 °C ......................... T ≤ max. time to trip (seconds) Hold Current ......................................................... 30 min. at Ihold ..................................................... No trip Trip Cycle Life ....................................................... Vmax, Imax, 100 cycles ........................................ No arcing or burning Trip Endurance ..................................................... Vmax, 48 hours..................................................... No arcing or burning Solderability .......................................................... MIL-STD-202F, Method 208F ............................... 95 % min. coverage UL File Number ..................................................... E174545 TÜV File Number .................................................. R2057213 Thermal Derating Chart - Ihold/Itrip (Amps) Model MF-SM013/250V -40 °C 0.21 / 0.42 -20 °C 0.18 / 0.37 0 °C 0.16 / 0.31 Ambient Operating Temperature 23 °C 40 °C 50 °C 0.13 / 0.26 0.10 / 0.23 0.09 / 0.18 60 °C 0.08 / 0.15 70 °C 0.07 / 0.12 *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 85 °C 0.05 / 0.10 MF-SM013/250V - Telecom PTC Resettable Fuses Recommended Pad Layout Product Dimensions 6.6 MAX. (.260) 2.29 (.090) 7.4 (.291) MAX. 2.29 (.090) 2.41 (.095) 3.43 (.135) 2.41 (.095) 6.35 (.250) 3.2 (.126) MAX. 1.94 (.076) DIMENSIONS: MM (INCHES) Terminal material: Tin-plated brass Packaging: TAPE & REEL: 1000 pcs. per reel Solder Reflow Recommendations 300 Preheating Soldering Cooling Temperature (°C) 250 200 150 100 Solder reflow • Recommended reflow methods: IR, vapor phase oven, hot air oven. • Devices are not designed to be wave soldered to the bottom side of the board. • Gluing the devices is not recommended. • Recommended maximum paste thickness is 0.25 mm (.010 inch). • Devices can be cleaned using standard industry methods and solvents. Note: • 50 If reflow temperatures exceed the recommended profile, devices may not meet the performance requirements. Rework 0 160–220 10–20 120 • A device should not be reworked. Time (seconds) Storage Recommendations The recommended long term storage conditions for Multifuse® Polymer PTC devices are 40 °C maximum and 70 % RH maximum. All devices should remain in the original sealed packaging prior to use. Devices may not conform with data sheet specifications if these storage recommendations are exceeded. Devices stored in this manner have an indefinite shelf life. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. MF-SM013/250V - Telecom PTC Resettable Fuses Typical Time to Trip at 23 ˚C Typical Part Marking Represents total content. Layout may vary. 20 10 MANUFACTURER'S TRADEMARK Time to Trip (Seconds) 013V 4C PART IDENTIFICATION DATE CODE: WEEK 3 OF 2004 = 4C WEEK 29 OF 2004 = C4 1 How to Order MF - SM 013/250V - 2 0.1 0.01 0.1 1 Fault Current (Amps) 5 Multifuse® Product Designator Series SM = Surface Mount Component Hold Current, Ihold 013 = 0.13 Amps Max. Interrupt Voltage, V 250 = 250 Volts Telecom Options V = Vertical Profile (Surface Mount Products Only) Packaging Options - 0 = Bulk Packaging - 2 = Tape and Reel* *Packaged per EIA486-B MF-SM013/250V, REV. F, 08/15 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. MF-SM/250V Series Tape and Reel Specifications MF-SM013/250V per EIA 481-1 Tape Dimensions W 16.0 ± 0.3 (0.630 ± 0.012) P0 4.0 ± 0.1 (0.157 ± 0.004) 8.0 ± 0.1 (0.315 ± 0.004) 2.0 ± 0.1 (0.079 ± 0.004) 3.3 ± 0.1 (0.130 ± 0.004) 6.66 ± 0.1 (0.262 ± 0.004) 7.2 (0.283) 1.5 ± 0.1 (0.059 ± 0.004) 7.5 ± 0.1 (0.295 + 0.004) 1.75 ± 0.1 (0.069 ± 0.004) P1 P2 A0 B0 B1 max. D0 F E1 14.25 (0.561) 0.45 (0.018) 0.1 (0.004) E2 min. T max. T1 max. 7.0 (0.276) 390 (15.35) 160 (6.30) K0 Leader min. Trailer min. Reel Dimensions N min. 340 (13.39) 50 (1.97) W1 16.4 (0.646) W2 max. 22.4 (0.882) A max. MM UNIT = (INCHES) P0 T D0 P2 E1 W2(MEASURED AT HUB) COVER TAPE F E2 W B1 A N(HUB DIA.) B0 K0 T1 P1 A0 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. W1(MEASURED AT HUB)