NT IA PL † Ro HS CO M Radial Lead RF Chokes Model 6000 is currently available, although not recommended for new designs. Model RLB9012 is preferred. Special Features • High current capacity • Ferrite bobbin core • Low core loss at frequency • High reliability, efficiency • Winding covered with shrink tubing • Fixed lead spacing • Operating temperature -55 to +105 °C Notes * Current to cause 5 % max. inductance drop † RoHS Directive 2002/95/EC Jan 27 2003 including Annex. 9.0 Max. 12.2 Max. 10 Min. 0.7 5.0 -/+0.3 Dimensions: mm Part Number L (µH) ±20 % 6000-1R0M-RC 6000-1R5M-RC 6000-2R2M-RC 6000-3R3M-RC 6000-4R7M-RC 6000-6R8M-RC 1.0 1.5 2.2 3.3 4.7 6.8 ±10 % 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 2700 3300 3900 4700 5600 6800 8200 10,000 12,000 15,000 18,000 22,000 27,000 33,000 39,000 47,000 6000-100K-RC 6000-120K-RC 6000-150K-RC 6000-180K-RC 6000-220K-RC 6000-270K-RC 6000-330K-RC 6000-390K-RC 6000-470K-RC 6000-560K-RC 6000-680K-RC 6000-820K-RC 6000-101K-RC 6000-121K-RC 6000-151K-RC 6000-181K-RC 6000-221K-RC 6000-271K-RC 6000-331K-RC 6000-391K-RC 6000-471K-RC 6000-561K-RC 6000-681K-RC 6000-821K-RC 6000-102K-RC 6000-122K-RC 6000-152K-RC 6000-182K-RC 6000-222K-RC 6000-272K-RC 6000-332K-RC 6000-392K-RC 6000-472K-RC 6000-562K-RC 6000-682K-RC 6000-822K-RC 6000-103K-RC 6000-123K-RC 6000-153K-RC 6000-183K-RC 6000-223K-RC 6000-273K-RC 6000-333K-RC 6000-393K-RC 6000-473K-RC 6000 Series Test Freq. Q (MHz) Min. SRF (MHz) Min. DCR Ω Max. I, DC* (A) 20 20 20 20 20 20 7.96 7.96 7.96 7.96 7.96 7.96 150 130 100 79 51 29 0.013 0.016 0.021 0.025 0.030 0.035 10 8.5 6.5 5.5 4.6 4.1 50 50 50 40 40 40 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.079 0.079 0.079 0.079 0.079 0.079 0.079 0.079 0.079 14 13 12 11 9.2 8.5 7.8 6.9 6.5 5.4 4.9 4.1 3.7 3.4 3.2 2.8 2.7 2.4 2.3 2.1 1.9 1.8 1.6 1.5 1.3 1.2 1.1 1.0 0.8 0.7 0.6 0.55 0.5 0.45 0.4 0.35 0.32 0.28 0.25 0.23 0.21 0.19 0.17 0.15 0.12 0.045 0.050 0.056 0.061 0.070 0.080 0.090 0.10 0.16 0.18 0.21 0.23 0.28 0.32 0.37 0.58 0.65 0.75 0.85 1.0 1.1 1.4 1.6 1.8 2.9 3.4 3.8 5.3 5.9 8.2 9.1 9.9 13.6 14.9 20.7 22.7 25.1 34.7 48.9 53.6 59.3 82.7 91.5 125.5 137.8 3.4 3.1 2.9 2.66 2.4 2.22 2.05 1.85 1.77 1.48 1.36 1.3 1.4 1.25 1.15 1.08 1.0 0.90 0.78 0.74 0.68 0.64 0.59 0.56 0.51 0.48 0.43 0.39 0.36 0.32 0.29 0.27 0.24 0.22 0.20 0.18 0.17 0.15 0.14 0.12 0.11 0.10 0.09 0.08 0.08 “-RC” suffix indicates RoHS compliance. Tel. (877) 426-8767 • Fax (951) 781-5006 REV. 06/07 www.bourns.com 15.1