u01

Features
n Built-in automatic voltage regulation enables a wide input voltage window to deliver power while preventing unnecessary battery
drain
n Internal bypass switch provides power if UPS fails and prevents unnecessary shutdown of connected equipment
n Listed to UL 60950-22 standard for outdoor
equipment
n Connectorized internal circuit board assemblies for easy repairs
n LED indicators show status of load and
batteries
n Heavy-duty surge protection and noise filtering protects load and UPS
n Wide temperature, pure lead, gel batteries and internal cooling fan extend battery life and protect electronic components
U01 Compact Series Outdoor UPS (AC/AC)
The Bourns® U01 Compact Series Outdoor Uninterruptible Power Supply (UPS) is equipped with wide-temperature, pure lead, gel
batteries and is housed in a weather-protected enclosure. It offers line-interactive automatic voltage regulation, over / under voltage
protection, surge protection with heavy-duty noise filtering, communications capability and optional extended battery back-up.
The U01 Series Compact Outdoor UPS provides automatic voltage regulation with surge protection and noise filtering, as well as
overvoltage protection with a threshold of 136 V and undervoltage protection with a threshold of 96 V. In the event of a brownout,
overvoltage, or loss of power, the UPS will transfer to battery power quickly, enabling uninterrupted operation of the critical load.
This Compact Outdoor UPS is ideal for the protection of outdoor telecommunications infrastructures, DAS Systems, perimeter
surveillance, security / gate control systems, LED traffic light and roadway display systems.
Characteristics
Specification
INPUT
Nominal Voltage & Frequency
Operating Voltage
Current @ 96 V & Max. Charging
Circuit Breaker
Model
U01120-050-120
7.8 A
10 A
Surge Withstand and Let-through
Voltage
OUTPUT
Voltage
Output Power
Crest Factor
Waveform and THD
Power Efficiency
Power On / Off Switch
Transfer Time
BATTERY
Type
Dimensions:
mm/(inches)
Weight
Ah @ 20 hr Rate and Bus Voltage
Number of Batteries
Battery Circuit Breaker
Battery Heater Pad BH 5
Battery Back-up Time vs. Load
Recharge Time
INDICATORS AND ALARMS
LED Status Indicators on Control
Board
N/O or N/C Contacts
500 W
Model
U01120-084-120
Model
U01120-105-120
116 V, 60 Hz
96 - 136 V
11.4 A
15 A
ANSI/IEEE:
6 kV, 1.2 x 50 µs
/
3 kA, 8 x 20 µs;
L-N: 450 V L-G: 300 V N-G: 300 V
115 V ± 8 %
840 W
3:1
Sine wave, < 3 % THD with linear load
Line: 97 %, Inverter: 92 % under full load conditions
On / off rocker style power switch
0 to 8 milliseconds
8GU1
14.2 A
15 A
1050 W
NP 18-12
180 x 76 x 167 (7.1 x 3 x 6.57)
196 x 132 x 183 (7.71 x 5.18 x 7.22)
13.7 lbs. / 6.2 kg
23 lbs. / 10.5 kg
31.6 Ah, 24 VDC
17.2 Ah, 48 VDC
2
4
30 A
40 A
40 A
34 W, one required
34 W, two required
32 min.
17 min.
27 min.
Temperature compensated charger, charge to 90 % capacity after full discharge
7 hrs.
Inverter on:
Amber: Low battery: Amber after inverter shut down following low battery after long outage;
Fault: Red for overload / red blinks for high temperature;
AC ok: Green when AC in buck, bypass or boost mode
>44 V / <44 V / or >22 V / <22 V / On / Off,
Six position terminal block on control board assembly
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Applications
Features (Continued)
n Perimeter surveillance cameras (CCTV)
n Wireless access points
n Industrial Remote Terminal Units (RTUs)
n Compact design
n Quiet - ideal for use in locations with noise
ordinances
n Pole or wall mounting options
n Precise output current limiting permits start-up of induction motors and other difficult loads
U01 Compact Series Outdoor UPS (AC/AC)
Characteristics (Continued)
Model
U01120-050-120
Specification
PHYSICAL
Dimensions
Aluminum Cabinet
Input / Output Connections
Weight with Batteries (lbs/kg)
Mounting Options
ENVIRONMENTAL
Model
U01120-105-120
419 mm (16.5 “) wide x 521 mm (20.5 “) high x 241 mm (9.5 “) deep
Outdoor type, power coated
3-position terminal block provided for 3 x 12 AWG, 7/8 “ holes for 1/2 “ conduit connectors
100 / 45.4
103 / 46.8
110 / 49.8
Wall mounting is standard; optional pole mounting bracket is available
+14 to +131 °F / -10 to +55 °C
-40 to +131 °F / -40 to +55 °C with BH5 optional battery heater
+149 °F / +65 °C
Thermostat controlled exhaust fan
Conformal coating of electronic boards for moisture resistance
Operating Temperature
Maximum Operating Temperature
Cooling Method
Moisture Protection
SAFETY
cETLus
Model
U01120-084-120
UL 1778 Ed: 4, CSA C22.2 #107.3, UL 60950-1, UL 60950-22, CSA C22.2#60950-22
Mounting Options
Product Images
Rear View
Front View
Wall Mount
Latching Options
Standard Slotted Latch
Key Lock
Bellcore 216
Pole Mount
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
U01 Compact Series Outdoor UPS (AC/AC)
How to Order
U01 120 - XXX - 120 - YY - __ - __
Series Designator
U01 = Compact Series Outdoor UPS (AC/AC)
Input Voltage
120 = 120 VAC
Power Rating
050 = 500 W
084 = 840 W
105 = 1050 W
Output Voltage
120 = 120 V
Battery Options
A = 2 Batteries
B = 4 Batteries
AH = 2 Battery with Heater
BH = 4 Batteries with Heater
Mounting Options
Blank = Wall (Standard)
1 = Pole Mount
Latching Options
Blank = Standard Slotted Latch
K = Key Lock
B = Bellcore 216
Standard Offering: Wall mount, Standard latch, 1 string, heated/unheated.
U01 Compact Series UPS (AC/AC) Schematic
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
REV. B 03/16
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.