LAM2SB600-38-1Y Product Page

ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
Two-Hole, Vertical Two-Barrel Lug
For Use with Stranded Aluminum or Copper Code Conductors
Type LAM2SB
• Dual barrel provides termination of two conductors
• Vertical configuration saves space
• Made from high strength, extruded aluminum alloy to provide
premium electrical and mechanical performance
• Tin-plated to inhibit corrosion
• Wide wire range-taking capability minimizes inventory requirements
• Inspection window to visually assure full conductor insertion
• Plated steel or aluminum set screw provides high strength, durable
electrical contact between conductor and connector
• UL Listed and CSA Certified for use up to 600 V and UL
temperature rated 90°C
P
L
W
W
HOLE
SPACING
HOLE
SPACING
C1.
Wiring
Duct
H1
P
H2
T
H1
H2
T
L
Figure 1
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
Figure
Part Number
No.
LAM2SB600-38-1Y*
1
Figure 2
Figure Dimensions
(In.)
Conductor Size Range
#2 AWG – 600 kcmil
Stud Hole
Size
(In.)
3/8
Stud Hole
Spacing
(In.)
1.38
Hex Key
Size
(In.)
3/8
L
4.91
W
1.50
H1
3.00
H2
1.88
T
0.75
P
2.34
Std.
Pkg.
Qty.
1
LAM2SB750-38-1Y*
1
1/0 AWG – 750 kcmil
3/8
1.38
3/8
4.91
1.50
3.00
1.88
0.75
2.34
1
LAM2SSB500-141Y
2
4/0 AWG – 500 kcmil
1/4
0.69
1/2
2.91
1.44
2.38
1.77
0.63
1.69
1
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155.
*UL Listed and CSA Certified.
Two-Hole, Three-Barrel Lug
D1.
Terminals
For Use with Stranded Aluminum or Copper Code Conductors
Type LAM3B
D2.
Power
Connectors
D3.
Grounding
Connectors
• Triple barrel provides termination of three conductors
• Made from high strength, extruded aluminum alloy to provide
premium electrical and mechanical performance
• Tin-plated to inhibit corrosion
• Wide wire range-taking capability minimizes inventory requirements
• Inspection window to visually assure full conductor insertion
• Plated steel or aluminum set screw provides high strength, durable
electrical contact between conductor and connector
• LAM3LB connector is provided with dual set screws to allow
premium clamping of conductor to connector for heavy
duty applications
• For use up to 600 V and temperature rated 90°C
• Available with NEMA hole sizes and spacing
L
L
HOLE
SPACING
E1.
Labeling
Systems
W
W
HOLE
SPACING
E2.
Labels
T
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
D2.144
H
Part Number
LAM3B1/0-38-6Y
Figure
No.
1
Conductor
Size Range
#14 AWG – 1/0 AWG
Stud
Hole
Size
(In.)
3/8
Stud Hole
Spacing
(In.)
1.00
P
H
Figure 2
Figure 1
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
T
P
Figure Dimensions
(In.)
Hex Key
Size
(In.)
**
L
2.91
W
2.00
H
0.88
T
0.25
P
2.16
Std.
Pkg.
Qty.
6
◆ LAM3B3/0-12-3Y
1
#6 AWG – 3/0 AWG
1/2
1.75
1/4
4.25
2.81
1.19
0.31
3.25
3
◆ LAM3B250-12-1Y
1
#6 AWG – 250 kcmil
1/2
1.75
5/16
4.00
2.82
1.19
0.31
3.00
1
◆ LAM3B350-12-1Y
1
#6 AWG – 350 kcmil
1/2
1.75
5/16
4.50
3.50
1.38
0.31
3.25
1
◆ LAM3LB600-12-1
2
#2 AWG – 600 kcmil
1/2
1.75
3/8
5.50
4.32
1.50
0.38
3.25
1
◆ LAM3LB1000-121Y
2
500 kcmil – 1000 kcmil
1/2
1.75
1/2
6.19
5.27
1.88
0.56
3.44
1
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155.
**Uses slotted head set screw.
◆NEMA hole sizes and spacing.
Prime items appear in BOLD.