SmartZone™ Gateway EPA126 S pe c i f i c a t i o n S H E E T specifications The Gateway EPA126 is installed as part of a primary/secondary topology and provides support for up to six connected power devices, 12 environmental sensors and two access control devices all through a single IP address. The gateway will allow for expansion of additional power devices, without need for additional network ports, using the Gateway EPAX18 Expansion Unit that connects to the base unit. The Gateway EPA126 consolidates all data captured from the connected power devices and sensors and displays baseline operational data through a web interface or via SmartZone™ Software platforms. The gateway supports keypad or card reader devices to provide cabinet access control. The gateway supports the "open" Simple Network Management Protocol (SNMP) to allow monitoring for conditions that warrant administrative attention via any network management system that supports the SNMP protocol, as well as supporting HTTP/HTTPS protocols for remote management capabilities. technical information Dimensions: Weight: Packaging: Mounting: 18 in. x 4.5 in. x 1.7 in. (465mm x 114mm x 44 mm) 4.76 lbs. (2.16Kg); 6.75 lbs. (3.06Kg) packaged 1.98 lbs. (0.9Kg) 19" rack mountable, housed in a 1RU metal case key features and benefits Centralized device management Connects up to six connected power devices, 12 environmental sensors and two access control devices into one intelligent gateway to consolidate monitoring and management of operational data, simplify troubleshooting, and allow faster polling of data Single IP address Allows all connected power devices and sensors to be combined through one single gateway IP address, reducing the need for separate IP ports, IP capital costs, and management overhead Primary/secondary network topology Houses the intelligence and power supply for connected devices within the gateway itself to simplify the network architecture and lower overall power consumption Access and control security Powers access control card readers on cabinets and manages encrypted access data to support smart card technologies and other readers that enhance data center security Scalable design Allows Gateway EPA126 to be attached to the Gateway EPAX18 Expansion Unit to provide additional power device inputs through the gateway’s single IP address, enabling cost-effective monitoring scalability and growth SNMP enabled Uses open SNMP protocol to provide alerts (traps) on potential service impacting power and environmental conditions to mitigate operational downtime HTTP/HTTPS web interface Provides authentication safeguards to securely allow users to configure, monitor, and control the gateway through remote management SmartZone ™ Software platform integration Consolidates power and environmental data to be utilized by SmartZone™ Software platforms for real-time monitoring and display, management, and automated documentation applications The SmartZone™ Gateway EPA126 is an innovative, SNMP based gateway that simplifies the management of power devices and sensors with one IP address, significantly reducing the number of IP addresses needed in the data center. This management information can then be displayed via an internal web interface or utilized by SmartZone™ Software platforms for real-time monitoring, management, and automated reporting of operational metrics. SmartZone™ Gateways are scalable solutions, ideally suited to brownfield or greenfield data centers and telco areas. When coupled with the SmartZone™ Gateway EPAX18 Expansion Unit, the number of power devices that can be monitored increases from 6 to 24, significantly improving flexibility and scalability. The SmartZone™ Gateway EPA126 supports up to six connected power devices, 12 environmental sensors and two access control devices. To enhance cabinet security, the Gateway EPA126 supports keypads or HID card readers, which, when used with electronic handles, provide secure access to the cabinet. w w w. pa n d u it.c o m SmartZone™ Gateway EPA126 Gateway EPA126 test data Power Supply Cable Wire Input Power 100~240 VAC Input Connector 2 x IEC C14 Inlet Power Consumption (Max) 40W Additional Information Isolated supply Internal PSU Dual Operating Environment Operating Temperature 32°F to 113°F (0°C to 45°C) Storage Temperature 14°F to 158°F (-10°C to 70°C) Operating Humidity 15% to 85% RH Storage Humidity 5% to 90% RH MTBF >100,000 Hrs. Connectivity and Networking Network Type Ethernet (802.3u) Network Connection RJ45 Link Speeds 10/100 Mbps with auto negotiation Network Indications Connection LED (Green); Network Speed LED (Yellow) Sensors Number of Inputs 12 sensor inputs Input Connector 8-way RJ45 Parameters Monitored Temperature, humidity, smoke, door contact, shock, water, PIR, airflow sensors, and any 0-10 VDC output sensor Temperature Monitoring Range 32°F to 140°F (0°C to 60°C) Temperature Monitoring Accuracy ±5% Standard Transducer @ 68°F (20°C) Humidity Monitoring Range 30% to 90% relative humidity Humidity Monitoring Accuracy ±5% RH @ 77°F (25°C) Analogue Resolution 12 Bit A/D for analogue inputs Additional Information Inputs are not isolated; auto detection of supported sensors Access and Control Access 2 ports that support 2x5 Keypad or HID Card Reader Control 4 relay output ports for controlling flashing beacons, or electronic handles PDU Monitoring and Control Number of Inputs 6 inputs for connected power monitoring devices PDU In/Out Connector RJ45 Parameters Monitored Volts, amps, total kVA, total kWh, total power factor, and frequency Voltage Monitoring Range 0V to 500V Current Monitoring Range 0A to 65A kWh Monitoring Range 0 kWh to 429496729 kWh kWh Monitoring Accuracy Dependent on PDU kWh Monitoring Accuracy Dependant on PDU 2 SmartZone™ Gateway EPA126 Gateway EPA126 test data (continued) Output Relays Cable Wire Number of Outputs 4 Output Connectors WeidMuller (Output 1and 2), Screw lock Pheonix Contact (Output 3 and 4) Output Connections Normally Open, Common, Normally Closed Maximum Switching 48V at 1A (Resistive Load) Additional Information 12V DC Output fused at 1AMP available on Weidmuller connector Monitoring and Configuration Outputs 1 and 2 offer a 12+ VDC supply fused at 1 Amp The following monitoring and configuration methods are provided Web management interface via HTTP or HTTPS (Secure); Configurable SNMP and email alarm messages Compliance UL 60950-1 2nd edition, CAN/CSA-C22.2 No. 60950-1-07 Incl. Amd 1, CAN/CSA-CISPR 22-10, FCC Part 15B.Emissions LCD Status Monitor The optional backlit LCD status monitor can display the following Summary page displaying configured PDUs and inputs 1 and 2, all 6 digital inputs and all 4 PDUs, alternative display via selector switches The following system information is also available Firmware version, IP address, sub-net mask, gateway, MAC address Additional Information Backlit, powered from unit (no additional power source required) Front Panel Indicators Green LED Network Ethernet connection present (flashing indicates traffic present) Yellow LED Network Speed Off indicates 10Mbps network; On indicates 100Mbps network link Green LED CPU Status Flash indicates correct operation of the Gateway EPA126 Red LED Alarm Status One or more sensor input has exceeded a pre-set threshold Blue LED Internal low voltage power supply is within range Yellow LED AC Feed A Presence of AC power on input Feed A Yellow LED AC Feed B Presence of AC power on input Feed B Rear Panel Indicators Green LED CPU Status Flashing indicates PDU Expansion Units CPU alive Blue LED Power ON Internal low voltage power supply is within range Red LED Alarm Status One or more sensor input has exceeded a pre-set threshold part numbers Gateway EPA126 Cable Wire ZAEI-01 SmartZone™ Gateway EPA126 – UK-IEC power cable ZAEI-01-99 SmartZone™ Gateway EPA126 – no power cable ZAEI-01-NA SmartZone™ Gateway EPA126 – NEMA 5-15 power cable ZAEI-01-UNI SmartZone™ Gateway EPA126 – IEC-IEC power cable Gateway EPAX18 Expansion Unit ZAEIPEXP01 SmartZone™ Gateway EPAX18 Expansion Unit – UK-IEC power cable ZAEIPEXP0199 SmartZone™ Gateway EPAX18 Expansion Unit – no power cable ZAEIPEXP01NA SmartZone™ Gateway EPAX18 Expansion Unit – IEC - NEMA 5-15 power cable ZAEIPEXP01UNI SmartZone™ Gateway EPAX18 Expansion Unit – IEC power leads (2x IEC-IEC) 3 SmartZone™ Gateway EPA126 part numbers (continued) Sensors ZAPDUMOD-03 LCD Display Module with Selector Switches ZAPDUMODKIT External LCD Display Kit with Case Enclosure FLABEA-01 Flashing Beacon with No Sounder FLABEA-02 Flashing Beacon with Sounder ZEAIR-02 Airflow Sensor ZECRDRKIT-01 HID Access Control Card Reader ZEDIC05-01 Digital Input Sensor ZEDL05-01 Door Contact Sensor (micro switch type) ZEDL05-02 Door Contact Sensor (magnetic type) ZEKPKIT-01 Keypad Kit ZEPIR-04 PIR Sensor ZESMA05-01 Smoke Detector ZESS04-01 Shock Sensor ZETHL-10 Humidity Sensor ZETHL-11 Temperature/Humidity Sensor ZETHL-12 Temperature Sensor ZETHL-13 External Temperature Sensor ZEWD3-05 Water Sensor (contact type) ZEWS-03-03 Water Sensor (rope type) Gateway EPA126 dimensions 1.260 [32.00] 1.677 [42.60] .138 [3.50] 18.455 [468.50] 1.677 [42.60] 19.016 [483.00] Dimensions are in inches. [Dimensions in brackets are metric]. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 ©2014 Panduit Corp. All rights reserved. PVSP109--WW-ENG 5/2014