Clamp Meter

SmartZone™ Clamp Meter
S p e c i f i c a t i o n S H EET
specifications
The clamp meter enables the non-invasive, real-time monitoring of single phase current for any device or
power strip rated up to 30A by placing the clamp meter directly over a non-armoured power cable with a
choice of locking-ring collars to suit international 20A and 30A cable sizes. The clamp meter will be installed
as part of a primary/secondary topology, where all critical intelligence and monitoring power supply for the
clamp meter is retained within a connected gateway. Data captured from the clamp meter will be used to
display baseline operational data through connected gateway firmware or through the SmartZone™ Software
Suite platform. The current flow is shown on a local display.
technical information
Dimensions:
Weight:
Packaging:
Mounting:
5.3 in. x 3.5 in. x 1.6 in. (134mm x 88mm x 40mm)
1.1 lbs. (0.5Kg); 2.2 lbs. (1Kg) packaged
1.1 lbs. (0.5Kg)
Zero RU; clips onto cable; free-standing
key features and benefits
Non-invasive
Allows device to be attached directly over single phase operating power cables and begin measuring power without
the need to power down monitored device, eliminating operational interruptions, while minimizing time delays and
risks that can be associated with downtime. Included adapters accommodate cable diameters between 0.31 in.
(8mm) and 0.71 in. (18mm). All cables in the vicinity of a clamp meter should be kept at least 100mm from the
clamp meter body, except for the cable being monitored
Extended intelligence
Layers intelligent monitoring capabilities over non-intelligent devices to quickly and cost-effectively integrate DCIM benefits
into legacy installations using patented technology
RJ45 connection
Utilizes an RJ45 plug to quickly connect SmartZone™ Clamp Meter to a SmartZone™ Gateway port, avoiding complex
wiring requirements and time delays
Primary/secondary
network topology
Connects to a SmartZone™ Gateway device that houses the intelligence and monitoring power supply for the
SmartZone™ Clamp Meter within the gateway itself to simplify the network architecture and lower overall
power consumption
Vendor neutral
Attaches to the power cable of any powered device to enable monitoring of any new or existing third-party devices,
cost-effectively maximizing resources
Zero RU form factor
Allows clamp meter to be attached in any convenient cable location within a rack or cabinet enclosure, simplifying and
accelerating deployment time and reducing the need for valuable rack space
SmartZone™ Software
suite integration
Captures initial power data that is consolidated by connected gateways and then utilized by SmartZone™ Software
Suite modules for real-time monitoring and display, management, and automated documentation
applications
SmartZone™ Power Monitoring Devices capture power consumption data of non-intelligent, vendor neutral equipment within IT and facility
domains. SmartZone™ Power Monitoring Devices operate using intelligence and monitoring power supplied by SmartZone™ Gateways, connected
via RJ45 ports. The gateways collect data captured from the power monitoring devices for display via gateway firmware or for utilization by
SmartZone™ Software platforms. Unique form factors simplify installations, allowing IT and facility teams to quickly and easily retrofit legacy
(brownfield) installations with intelligence capabilities in a manner that cost-effectively maximizes current resources.
The Panduit® SmartZone™ Clamp Meter captures basic power consumption of non-intelligent devices by attaching the clamp meter casing directly
over a live power cable and then easily plugging the clamp meter into an RJ45 gateway port. This rapidly initiates power consumption monitoring
and measurement without the service interruption of powering down devices.
w w w. pa n d u it.c o m
SmartZone™ Clamp Meter
c a b l e t y p e s s u p p o r t e d – E M EA
Calibration B-Values
Value
Region
Cable Type
52.000
EMEA
Titanex 3G6 3 Core 6mm2
54.580
EMEA
K-WELL SHIN H07RN-F 3C 6.0mm2 <VDE>
58.358
EMEA
Pirelli 3G4 3 Core 4mm2
59.750
EMEA
Doncaster Cables England 3 Core 4mm2
60.819
EMEA
Titanex 3G4 3 Core 4mm2
60.252
EMEA
Lineax 3G4 3 Core 4mm2
61.000
EMEA
ESSEX ROYAL 10/3 TYPE SOW 90C (-40C) 600V WATER RESISTANT E42608-B(UL)
CSA LL35441-B FT2...P-159-18 MSHA
73.750
EMEA
3x2.5 HO5VV-F TO BS6500
75.933
EMEA
IEMMEQU <HAR> HO7RN-F 3G3.5mm2 ARISTONCAVI 2008
95.142
EMEA
3 x 1.5 3 Core 1.5mm2
113.920
EMEA
3G1.5 3 Core 1.5mm2
122.675
EMEA
BKS BS6500 HO5VV-F
cable types supported – North America
Calibration B-Values
Value
Region
Cable Type
53.860
US
E56356 60°C 300V 10-3 SJTW FT2 (UL) (-50°C) WATER RESISTANT C (UL) 60°C (140°F)
300V 3X5.26mm (10AWG)
55.200
US
(UL) E166124 SJT 3x5.251mm2 (10AWG) 105°C (221°F) 300V VW-1 SWAIN CSA LL105054
TYPE SJT 3x5.251mm2 (10AWG) 105°C (221°F) 300V FT-2
55.710
US
(UL) SJT E55333 VW-1 3C/10AWG 300V LONGWELL-P CSA TYPE SJT FT2
56.580
US
(UL) SJT 60°C (140°F) E55333 VW-1 3x5.26mm (10AWG) 300V LONGWELL-P CSA 152192 TYPE SJT 60°C
3x5.26mm (10AWG) 300V FT2
57.000
US
AMERICAN INSULATED WIRE-K 10/3 SE00N(UL) 600V -50C to 105C CSA LL 8825 ST00W(TPE)600V -50°C
to 105C FT2 WATER RESISTANT p-7K 136032 MSHA LEAD FREE
57.390
US
TF CABLE FLEXTREME 3/C 10AWG (5.3mm )(UL) SOOW E123366 90°C (194°F) SUN and WATER RES 600V
CSA SOOW 90°C (194°F) LL103932 FT2 -40°C P-7K-254013 MSHA 026/11
57.800
US
(UL) E166124 SJT 3x5.251mm2 (10AWG) 105°C 300V VW-1 SWAIN CSA LL105054 TYPE SJT 3x5.251mm2
(10AWG) 105°C (221°F) 300V FT-2
58.200
US
(UL) E166124 SJT 3x5.251mm2 (10AWG) 105°C (221°F) 300V VW-1 SWAIN CSA LL105054 TYPE SJT
3x5.251mm2 (10AWG) 105°C 300V FT-2. Black plug
59.630
US
C (UL)US E90155-D SJTW 3x5.26mm (10AWG) 105°C 300V VW-1 WELL SHIN
61.167
US
Southwire Viper (S) 3/C 10 AWG (5.26mm2) SOOW (UL) 600V 74 12/
62.240
US
CCI SEOPRENE 105 10AWG (5.26mm) 3/C SJEOOW E54864 (UL) 300V -50°C TO
105°C (-58°F to 221°F) CSA LL39753 SJTOOW (TPE) -50°C TO 105°C (-58°F to 221°F) WATER-RESISTANT
63.900
US
(UL) E166124 SJT 3x5.251mm2 (10AWG) 105°C (221°F) 300V VW-1 SWAIN CSA LL105054
TYPE SJT 3x5.251mm2 (10AWG) 105°C 300V FT-2. White plug
64.030
US
CCI 10AWG (5.26mm ) 3/C ST E54864 (UL) 60°C (140°F) 600V – CSA LL39753 ST 60°C (140°F) 600V FT1
67.160
US
CAROL 10/3 90C (UL) WATER RESISTANT SOOW CSA (-40) FT-2 P-7K-123033 MSHA MADE IN USA 600V
74.000
US
Southwire Viper (S) 3/C 12 AWG (3.31mm2) SOOW (UL) 600V
88.150
US
HELUKABEL <VDE><HAR> CE E192384 (UL) SJT 3x12 AWG 60C 300V FT2 LL113926 CSA SJT 60C FT2
102.000
US
Southwire Viper (S) 3/C 14 AWG (3.58mm2) SOOW (UL) 600V
109.370
US
Southwire Viper (S) 3/C 12 AWG (3.31mm2) SJOOW (UL) 300V
113.330
US
(UL) SJT E159216 VW-1 3X14AWG BAOHING CSA SJJ LL112007-1 3X14AWG LF
2
SmartZone™ Clamp Meter
cable types supported – Japan
Calibration B-Values
Value
Region
Cable Type
56.9
JAPAN
13245006 (VCT 5.5mm2 <PS> E FUJI E.W.C 2011)
60.4
JAPAN
5.5mm VCT <PS>E JCT TEIKOKU 2014 LFV [VCT 3x5.5 (WBG/Y)]
64.5
JAPAN
<PS>E MITSUBOSHI VCT 5.5mm 200 [VCT 3x5.5 (WBG)]
68.700
JAPAN
<PS> E JET HOKUETSU.D 2012 V7
92.500
JAPAN
<PS>E <> KAWAI VCT 2012 DAN-SOFT 3.5mm2 LFV-R
92.1
JAPAN
13245005 (VCT 3.5mm2 <PS> E FUJI E.W.C 2012)
102.2
JAPAN
<PS>E MITSUBOSHI VCT 3.5mm 2013 P [VCT 3.5x3 (WBG)]
119.100
JAPAN
T<PS>E JET YUKITA S.BAOXING.D.D.Z S-VCT 2.0mm2 2013 LF
144.7
JAPAN
<PS> E JET HOKUETSU.D 2013 2.0mm²
146.5
JAPAN
<PS>E JET YUKITA 300V 2013 LFV [VCTF (KZ-VCTFS-2M)]
147.3
JAPAN
13245007 (VCT 2mm2 <PS> E FUJI E.W.C 2012 -F-)
Not supported
JAPAN
<PS>E JET YUKITA VCT 2013 LFV) SVCT-IV
part numbers
Clamp Meter
ZACLAMP-01
Cable Wire
Clamp Meter
Included in SmartZone™ Rack Energy Kits
RMSC2T2PCLA01
(2) Clamp Meter (non-invasive), (1) Gateway, (2) Temperature Sensors, and Rack
Monitoring Software
SmartZone™ Gateway Devices
ZARKMS-01-NA
SmartZone™ Gateway EP042 with IEC – NEMA 5-15 power cable
ZARKMS-01-UNI
SmartZone™ Gateway EP042 with IEC – IEC power cable
ZARKMS-01-99
SmartZone™ Gateway EP042 (no power cable)
ZAHI3-01-NA
SmartZone™ Gateway EPA064 with IEC – NEMA 5-15 power cable
ZAHI3-01-UNI
SmartZone™ Gateway EPA064 with IEC – IEC power cable
ZAHI3-01-99
SmartZone™ Gateway EPA064 (no power cable)
ZAEI-01-NA
SmartZone™ Gateway EPA126 with IEC – NEMA 5-15 power cable
ZAEI-01-UNI
SmartZone™ Gateway EPA126 with IEC – IEC power cable
ZAEI-01-99
SmartZone™ Gateway EPA126 (no power cable)
ZAEIPEXP01NA
SmartZone™ Gateway Expansion Unit EPAX18 with IEC – NEMA 5-15 power cable
ZAEIPEXP01UNI
SmartZone™ Gateway Expansion Unit EPAX18 with IEC power leads
ZAEIPEXP-01-99
SmartZone™ Gateway Expansion Unit EPAX18 (no power cable)
3
SmartZone™ Clamp Meter
clamp meter
134
5.3
[134]
88
3.5
[88]
40
1.6
[40]
Dimensions are in inches. [Dimensions in brackets are metric].
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
[email protected]
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
[email protected]
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
[email protected]
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
[email protected]
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
[email protected]
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
[email protected]
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: [email protected]
or by phone: 800.777.3300
©2014 Panduit Corp.
All rights reserved.
PVSP96--WW-ENG
8/2014