MAQ5280YME Evaluation Board User Guide

MAQ5280 Evaluation Board
25mA, 120V, Low IQ, High PSRR LDO
Automotive
General Description
The MAQ5280 is a high performance, linear regulator,
offering a very low noise output with a very wide input
voltage operating range, from 4.5V to 120V DC input
voltage.
Ideal for high input voltage applications such as
automotive and telecom, the MAQ5280 offers 2% initial
accuracy, extremely high power supply rejection ratio
(PSRR > 80dB) and low ground current (typically 31µA).
The MAQ5280 can also be put into a zero-off-mode
current state, drawing minuscule amount of current when
disabled.
The MAQ5280 has a very wide input voltage range, with
DC rated from –24V to +120V. This wide input range
covers the automotive load dump range and the
MAQ5280 is optimized for line transient response, making
it ideal for harsh environment applications.
Requirements
The MAQ5280 evaluation board requires an input power
source that is able to deliver greater than 0.1A at
+120VDC.
Precautions
The evaluation board does not have reverse polarity
protection. Applying a negative voltage lower than –24V to
the VIN (J1) terminal may damage the device.
The MAQ5280 evaluation board is tailored for a 4.5V to
120V input voltage range. The input voltage range should
not exceed 120VDC on the input.
Getting Started
1. Connect an external supply to the VIN. Apply
desired input voltage to the VIN (J1) and ground
(J2) terminals of the evaluation board, paying
careful attention to polarity and supply voltage
(4.5V ≤ VIN ≤ 120V). An ammeter may be placed
between the input supply and the VIN terminal to
the evaluation board. Ensure that the supply
voltage is monitored at the VIN terminal. The
ammeter and/or power lead resistance can
reduce the voltage supplied to the input.
2. Enabling the MAQ5280. The MAQ5280 has an
enable pin EN for enable/disable functionality.
EN: A logic high will turn on the linear regulator
and a logic low will shut down the linear regulator
reducing the quiescent current to less than
0.02µA (typical).
Output Voltage
The output voltage on the MAQ5280 evaluation board is
adjustable. The output voltage is controlled by the
feedback resistors (R1 and R2) and can be calculated as
follows:
⎛ R1 ⎞
+ 1⎟
VOUT = VREF ⋅ ⎜
⎝ R2
⎠
VREF = 1.219V
The evaluation board is initially adjusted to 5V, but can
easily be modified by removing R1 and replacing it with
the value that yields the desired output voltage.
⎛V
⎞
R1 = R2 ⋅ ⎜⎜ OUT − 1⎟⎟
⎝ VREF
⎠
Ensure the output voltage selected does not exceed 5V.
Ordering Information
Part Number
Description
MAQ5280YME EV
Evaluation board for the
MAQ5280QYME device
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
September 2008
M9999-091708-A
Micrel, Inc.
MAQ5280 Evaluation Board
Evaluation Board Schematic
Bill of Materials
Item
Part Number
NMC-P1210X7R184K200TRPLPF
C1
C1812C184K2RAC
VJ1812Y184KXC
R1
R2
NIC
Description
(1)
Kemet
Qty.
0.18µF, 200V, 1210, X7R Ceramic Capacitor
(2)
0.18µF, 200V, 1812, X7R Ceramic Capacitor
(3)
Vishay
C1608X5R1A225K
TDK(4)
0603C225MAT
AVX(5)
GRM188R60J225KE19D
Murata(6)
C1608X5R0J105K
TDK(4)
VJ0603G105KXYPW1BC
Vishay(3)
GRM188R60J105KA01D
(6)
C2
C3
Manufacturer
1
2.2µF, 6.3V, 0603, X5R Ceramic Capacitor
1
0.1µF, 6.3V, 0603, X5R Ceramic Capacitor
1
Murata
CRCW060315R4FKEYE3
Vishay Dale(4)
15.4k, 0603, 1%, 1/16W Resistor
1
CRCW06034R87FKEYE3
(4)
4.87k, 0603, 1%, 1/16W Resistor
1
(7)
25mA, 120V, Low IQ, High PSRR LDO
1
U1
MAQ5280YME
Vishay Dale
Micrel, Inc.
Notes:
1. NIC: www.niccomp.com
2. Kemet: www.kemet.com
3. Vishay: www.vishay.com
4. TDK: www.tdk.com
5. AVX: www.avx.com
6. Murata: www.murata.com
7. Micrel, Inc.: www.micrel.com
September 2008
2
M9999-091708-A
Micrel, Inc.
MAQ5280 Evaluation Board
PCB Layout Recommendations
Top Layer
Bottom Layer
September 2008
3
M9999-091708-A
Micrel, Inc.
MAQ5280 Evaluation Board
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its
use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product
can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical
implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A
Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully
indemnify Micrel for any damages resulting from such use or sale.
© 2008 Micrel, Incorporated.
September 2008
4
M9999-091708-A