TISP4xxxM3AJ

*R
oH
S
CO
M
PL
IA
NT
TISP4070M3AJ THRU TISP4115M3AJ,
TISP4125M3AJ THRU TISP4220M3AJ,
TISP4240M3AJ THRU TISP4395M3AJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4xxxM3AJ Overvoltage Protector Series
4 kV 10/700, 100 A 5/310 ITU-T K.20/21 rating
SMAJ Package (Top View)
SMA (DO-214AC) Package
25% Smaller Placement Area than SMB
Low Differential Capacitance ........................................... 39 pF
R (B) 1
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
VDRM
V(BO)
V
V
‘4070
58
70
‘4080
65
80
‘4090
68
90
‘4095
75
95
‘4115
90
115
‘4125
100
125
‘4145
120
145
‘4165
135
165
‘4180
145
180
‘4200
155
200
‘4220
160
220
‘4240
180
240
‘4250
190
250
‘4265
200
‘4290
220
‘4300
Device
2 T (A)
MDXXCCE
Device Symbol
T
SD4XAA
R
T erminals T and R correspond to the
alternative line designators of A and B
Rated for International Surge Wave Shapes
ITSP
Wave Shape
Standard
2/10 µs
GR-1089-CORE
300
265
8/20 µs
IEC 61000-4-5
220
290
10/160 µs
FCC Part 68
120
230
300
10/700 µs
ITU-T K.20/21/45
100
‘4320
240
320
10/560 µs
FCC Part 68
75
‘4350
275
350
10/1000 µs
GR-1089-CORE
50
‘4360
290
360
‘4395
320
395
A
............................................ UL Recognized Components
How To Order
Device
Package
Order As
Carrier
TISP 4xxxM3AJ AJ (J-Bend DO-214AC/SMA) Embossed Tape Reeled
TISP4xxxM3AJR-S
Insert xxx value corresponding to protection voltages of 070, 080, 095, etc.
Description
These devices are designed to limit overvoltages on the telephone line. Overvoltages are normally caused by a.c. power system or lightning
flash disturbances which are induced or conducted on to the telephone line. A single device provides 2-point protection and is typically used
for the protection of 2-wire telecommunication equipment (e.g. between the Ring and Tip wires for telephones and modems). Combinations of
devices can be used for multi-point protection (e.g. 3-point protection between Ring, Tip and Ground).
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially clipped by breakdown clamping until
the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on state. This low-voltage on state causes the
current resulting from the overvoltage to be safely diverted through the device. The high crowbar holding current helps prevent d.c. latchup as
the diverted current subsides.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
Description (continued)
The TISP4xxxM3AJ range consists of twenty voltage variants to meet various maximum system voltage levels (58 V to 320 V). They are
guaranteed to voltage limit and withstand the listed international lightning surges in both polarities. These medium (M) current protection
devices are in a plastic package SMAJ (JEDEC DO-214AC with J-bend leads) and supplied in embossed tape reel pack. For alternative
voltage and holding current values, consult the factory. For higher rated impulse currents, the 100 A 10/1000 TISP4xxxH3BJ series in the SMB
(JEDEC DO-214AA) package is available.
Absolute Maximum Ratings, TA = 25 °C (Unless Otherwise Noted)
Rating
Repetitive peak off-state voltage, (see Note 1)
Symbol
‘4070
‘4080
‘4090
‘4095
‘4115
‘4125
‘4145
‘4165
‘4180
‘4200
‘4220
‘4240
‘4250
‘4265
‘4290
‘4300
‘4320
‘4350
‘4360
‘4395
VDRM
Value
± 58
± 65
± 68
± 75
± 90
±100
±120
±135
±145
±155
±160
±180
±190
±200
±220
±230
±240
Unit
V
±275
±290
±320
Non-repetitive peak on-state pulse current (see Notes 2, 3 and 4)
2/10 µs (GR-1089-CORE, 2/10 µs voltage wave shape)
300
8/20 µs (IEC 61000-4-5, combination wave generator, 1.2/50 voltage, 8/20 current)
220
10/160 µs (FCC Part 68, 10/160 µs voltage wave shape)
120
5/200 µs (VDE 0433, 10/700 µs voltage wave shape)
110
ITSP
A
0.2/310 µs (I3124, 0.5/700 µs voltage wave shape)
100
5/310 µs (ITU-T K.20/21/45, K.44 10/700 µs voltage wave shape)
100
5/310 µs (FTZ R12, 10/700 µs voltage wave shape)
100
10/560 µs (FCC Part 68, 10/560 µs voltage wave shape)
75
10/1000 µs (GR-1089-CORE, 10/1000 µs voltage wave shape)
50
Non-repetitive peak on-state current (see Notes 2, 3 and 5)
20 ms (50 Hz) full sine wave
23
ITSM
16.7 ms (60 Hz) full sine wave
24
A
1000 s 50 Hz/60 Hz a.c.
1.6
Initial rate of rise of on-state current, Exponential current ramp, Maximum ramp value < 100 A
di T/dt
300
A/µs
Junction temperature
TJ
-40 to +150
°C
Storage temperature range
Tstg
-65 to +150
°C
NOTES: 1. See Applications Information and Figure 10 for voltage values at lower temperatures.
2. Initially, the TISP4xxxM3AJ must be in thermal equilibrium with TJ = 25 °C.
3. The surge may be repeated after the TISP4xxxM3AJ returns to its initial conditions.
4. See Applications Information and Figure 11 for current ratings at other temperatures.
5. EIA/JESD51-2 environment and EIA/JESD51-3 PCB with standard footprint dimensions connected with 5 A rated printed wiring
track widths. See Figure 9 for the current ratings at other durations. Derate current values at -0.61 %/°C for ambient temperatures
above 25 ° C.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
Electrical Characteristics, TA = 25 °C (Unless Otherwise Noted)
IDRM
V(BO)
V(BO)
I(BO)
VT
IH
dv/dt
Parameter
Repetitive peak offstate current
Breakover voltage
Impulse breakover
voltage
Breakover current
On-state voltage
Holding current
Critical rate of rise of
off-state voltage
Test Conditions
VD = VDRM
dv/dt = ±250 V/ms, R SOURCE = 300 Ω
dv/dt ≤ ±1000 V/µs, Linear voltage ramp,
Maximum ramp value = ±500 V
di/dt = ±20 A/µs, Linear current ramp,
Maximum ramp value = ±10 A
dv/dt = ±250 V/ms, R SOURCE = 300 Ω
I T = ±5 A, t W = 100 µs
I T = ±5 A, di/dt = +/-30 mA/ms
Linear voltage ramp, Maximum ramp value < 0.85V DRM
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TA = 25 °C
TA = 85 °C
‘4070
‘4080
‘4090
Min
Max
±5
±10
±70
±80
±90
‘4095
‘4115
‘4125
‘4145
‘4165
‘4180
‘4200
‘4220
‘4240
‘4250
‘4265
‘4290
‘4300
‘4320
±95
±115
±125
±145
±165
±180
±200
±220
±240
±250
±265
±290
±300
±320
‘4350
‘4360
‘4395
‘4070
‘4080
‘4090
±350
±360
±395
±78
±88
±98
‘4095
‘4115
‘4125
‘4145
‘4165
‘4180
‘4200
‘4220
‘4240
‘4250
‘4265
‘4290
‘4300
‘4320
±102
±122
±132
±151
±171
±186
±207
±227
±247
±257
±272
±298
±308
±328
‘4350
‘4360
‘4395
±359
±370
±405
±0.15
±0.15
±5
Typ
±0.6
±3
±0.35
Unit
µA
V
V
A
V
A
kV/µs
TISP4xxxM3AJ Overvoltage Protector Series
Electrical Characteristics, TA = 25 °C (Unless Otherwise Noted)
Parameter
ID
Test Conditions
Off-state current
Min
VD = ±50 V
4070 thru ‘4115
‘4125 thru ‘4220
‘4240 thru ‘4400
‘4070 thru ‘4115
‘4125 thru ‘4220
‘4240 thru ‘4395
‘4070 thru ‘4115
‘4125 thru ‘4220
‘4240 thru ‘4395
‘4070 thru ‘4115
‘4125 thru ‘4220
‘4240 thru ‘4400
‘4125 thru ‘4220
‘4240 thru ‘4395
f = 1 MHz, Vd = 1 V rms, VD = -1 V
Off-state capacitance
f = 1 MHz, Vd = 1 V rms, VD = -2 V
f = 1 MHz, Vd = 1 V rms, VD = -50 V
f = 1 MHz, Vd = 1 V rms, VD = -100 V
(see Note 6)
NOTE
Max
Unit
±10
µA
83
62
50
78
56
45
72
52
42
36
26
19
21
15
100
74
60
94
67
54
87
62
50
44
31
22
25
18
pF
Typ
Max
Unit
TA = 85 °C
f = 1 MHz, Vd = 1 V rms, VD = 0,
Coff
Typ
6: To avoid possible voltage clipping, the ‘4125 is tested with V D = -98 V.
Thermal Characteristics
Parameter
RθJA
NOTE
Junction to free air thermal resistance
Test Conditions
Min
EIA/JESD51-3 PCB, IT = ITSM(1000),
TA = 25 °C, (see Note 7)
265 mm x 210 mm populated line card,
4-layer PCB, IT = ITSM(1000), TA = 25 °C
115
°C/W
52
7: EIA/JESD51-2 environment and PCB has standard footprint dimensions connected with 5 A rated printed wiring track widths.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
Parameter Measurement Information
+i
Quadrant I
ITSP
Switching
Characteristic
ITSM
IT
V(BO)
VT
I(BO)
IH
V DRM
-v
IDRM
ID
VD
ID
IDRM
VD
VDRM
+v
IH
I(BO)
V(BO)
VT
IT
ITSM
I
Quadrant III
ITSP
Switching
Characteristic
-i
Figure 1. Voltage-Current Characteristic for T and R Terminals
All Measurements are Referenced to the R Terminal
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
PMXXAAB
TISP4xxxM3AJ Overvoltage Protector Series
Typical Characteristics
OFF-STATE CURRENT
vs
JUNCTION TEMPERATURE
1.10
TCMAG
100
NORMALIZED BREAKOVER VOLTAGE
vs
JUNCTION TEMPERATURE TC4MAF
Normalized Breakover Voltage
VD = ±50 V
|I D| - Off-State Current - µA
10
1
0·1
0·01
0·001
1.05
1.00
0.95
-25
0
25
50
75
100
TJ - Junction Temperature - °C
125
150
-25
ON-STATE CURRENT
vs
ON-STATE VOLTAGE
50
40
30
TA = 25 °C
t W = 100 µs
10
5
4
3
2
1.5
1
0.7
'4125
THRU
'4200
'4240
THRU
'4395
1
NORMALIZED HOLDING CURRENT
vs
JUNCTION TEMPERATURE TC4MAD
1.5
20
15
7
2.0
TC4MACC
Normalized Hol ding Current
IT - On-State Current - A
70
150
Figure 3.
Figure 2.
100
0
25
50
75
100 125
TJ - Junction Temperature - °C
Figure 4.
0.9
0.8
0.7
0.6
0.5
'4070
THRU
'4115
1.5
2
31 4 5
VT - On-State Voltage - V
1.0
0.4
7
10
-25
0
25
50
75
100
TJ - Junction Temperature - °C
125
150
Figure 5.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
Typical Characteristics
TJ = 25 °C
Vd = 1 Vrms
0.8
0.7
0.6
0.5
'4070 THRU '4115
0.4
'4125 THRU '4200
0.3
'4240 THRU '4395
0.2
0.5
TCMAEB
40
0.9
Capacitance Normali zed to VD = 0
DIFFERENTIAL OFF-STATE CAPACITANCE
vs
RATED REPETITIVE PEAK OFF-STATE VOLTAGE
∆C - Differential Off-State Capacitance- pF
1
NORMALIZED CAPACITANCE
vs
OFF-STATE VOLTAGE
TC4MABC
1
2
3
5
10
20 30
VD - Off-state Voltage - V
50
35
∆C = Coff(-2 V) - Coff (-50 V)
30
25
20
100 150
50
Figure 6.
Figure 7.
3
|Coff(+VD) - Coff(-VD) | — Capacitance Asymmetry — pF
60 70 80 90 100
150
200 250 300 350
VDRM - Repetitive Peak Off-State Voltage - V
TYPICAL CAPACITANCE ASYMMETRY
vs
OFF-STATE VOLTAGE
TC4XBB
Vd = 10 mV rms, 1 MHz
2
1
Vd = 1 V rms, 1 MHz
0
0.5 0.7 1
2
3 4 5
7 10
VD — Off-State Voltage — V
Figure 8.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
20 30 4050
TISP4xxxM3AJ Overvoltage Protector Series
Rating and Thermal Information
ITSM(t) - Non-Repetitive Peak On-State Current - A
NON-REPETITIVE PEAK ON-STATE CURRENT
vs
CURRENT DURATION
TI4MAl
20
VGEN = 600 Vrms, 50/60 Hz
RGEN = 1.4*VGEN / ITSM(t)
EIA/JESD51-2 ENVIRONMENT
EIA/JESD51-3 PCB
TA = 25 °C
15
10
9
8
7
6
5
4
3
2
1.5
0·1
1
10
100
1000
t - Current Duration - s
Figure 9.
IMPULSE RATING
vs
AMBIENT TEMPERATURE
VDRM DERATING FACTOR
vs
MINIMUM AMBIENT TEMPERATURE
400
TI4MADAB
1.00
Impulse Current - A
Derating Factor
250
'4125 THRU '4200
0.97
0.96
0.95
BELLCORE 2/10
300
0.99
0.98
TC4MAA
'4070 THRU '4115
FCC 10/160
120
100
90
80
70
ITU-T 10/700
FCC 10/560
50
'4240 THRU '4395
0
5
10 15 20 25
TAMIN - Minimum Ambient Temperature - °C
Figure 10.
150
60
0.94
0.93
-40 -35 -30 -25 -20 -15 -10 -5
IEC 1.2/50, 8/20
200
40
-40 -30 -20 -10 0
BELLCORE 10/1000
10 20 30 40 50 60 70 80
TA - Ambient Temperature - °C
Figure 11.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
APPLICATIONS INFORMATION
Deployment
These devices are two terminal overvoltage protectors. They may be used either singly to limit the voltage between two conductors (Figure 12)
or in multiples to limit the voltage at several points in a circuit (Figure 13).
Th3
Th1
Th1
Th2
Figure 12. Two Point Protection
Figure 13. Multi-Point Protection
In Figure 12, protector Th1 limits the maximum voltage between the two conductors to ±V(BO). This configuration is normally used to protect
circuits without a ground reference, such as modems. In Figure 13, protectors Th2 and Th3 limit the maximum voltage between each conductor and ground to the ±V(BO) of the individual protector. Protector Th1 limits the maximum voltage between the two conductors to its ±V(BO)
value. If the equipment being protected has all its vulnerable components connected between the conductors and ground, then protector Th1
is not required.
Impulse Testing
To verify the withstand capability and safety of the equipment, standards require that the equipment is tested with various impulse wave forms.
The table below shows some common values.
Standard
Peak Voltage
Setting
V
Voltage
Wave Shape
µs
2/10
10/1000
10/160
10/560
9/720 †
9/720 †
0.5/700
Peak Current
Value
A
Current
Wave Shape
µs
TISP4XXXM3
25 °C Rating
A
Series
Resistance
Ω
2500
500
2/10
300
11
1000
100
10/1000
50
1500
200
10/160
120
2x5.6
800
100
10/560
75
3
FCC Part 68
1500
37.5
5/320 †
100
0
(March 1998)
1000
25
5/320 †
100
0
I3124
1500
37.5
0.2/310
100
0
37.5
1500
5/310
100
0
10/700
ITU-T K.20/K.21
100
4000
† FCC Part 68 terminology for the waveforms produced by the ITU-T recommendation K.21 10/700 impulse generator
GR-1089-CORE
If the impulse generator current exceeds the protector’s current rating, then a series resistance can be used to reduce the current to the
protector’s rated value to prevent possible failure. The required value of series resistance for a given waveform is given by the following
calculations. First, the minimum total circuit impedance is found by dividing the impulse generator’s peak voltage by the protector’s rated
current. The impulse generator’s fictive impedance (generator’s peak voltage divided by peak short circuit current) is then subtracted from the
minimum total circuit impedance to give the required value of series resistance.
For the FCC Part 68 10/560 waveform, the following values result. The minimum total circuit impedance is 800/75 = 10.7 Ω and the generator’s
fictive impedance is 800/100 = 8 Ω. This gives a minimum series resistance value of 10.7 - 8 = 2.7 Ω. After allowing for tolerance, a 3 Ω ±10%
resistor would be suitable. The 10/160 waveform needs a standard resistor value of 5.6 Ω per conductor. These would be R1a and R1b in
Figure 15 and Figure 16. FCC Part 68 allows the equipment to be non-operational after the 10/160 (conductor to ground) and 10/560 (interconductor) impulses. The series resistor value may be reduced to zero to pass FCC Part 68 in a non-operational mode, e.g. Figure 14. For this
type of design, the series fuse must open before the TISP4xxxM3 fails. For Figure 14, the maximum fuse i2t is 2.3 A2s. In some cases, the
equipment will require verification over a temperature range. By using the rated waveform values from Figure 11, the appropriate series resistor
value can be calculated for ambient temperatures in the range of -40 °C to 85 °C.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
AC Power Testing
The protector can withstand currents applied for times not exceeding those shown in Figure 9. Currents that exceed these times must be
terminated or reduced to avoid protector failure. Fuses, PTC (Positive Temperature Coefficient) thermistors and fusible resistors are overcurrent
protection devices which can be used to reduce the current flow. Protective fuses may range from a few hundred milliamperes to one ampere.
In some cases, it may be necessary to add some extra series resistance to prevent the fuse opening during impulse testing. The current versus
time characteristic of the overcurrent protector must be below the line shown in Figure 9. In some cases, there may be a further time limit
imposed by the test standard (e.g. UL 1459 wiring simulator failure).
Capacitance
The protector characteristic off-state capacitance values are given for d.c. bias voltage, V D, values of 0, -1 V, -2 V and -50 V. Where possible
values are also given for -100 V. Values for other voltages may be calculated by multiplying the VD = 0 capacitance value by the factor given in
Figure 6. Up to 10 MHz, the capacitance is essentially independent of frequency. Above 10 MHz, the effective capacitance is strongly
dependent on connection inductance. In many applications, such as Figure 15 and Figure 17, the typical conductor bias voltages will be about
-2 V and -50 V. Figure 7 shows the differential (line unbalance) capacitance caused by biasing one protector at -2 V and the other at -50 V.
Figure 8 shows the typical capacitance asymmetry; the difference between the capacitance measured with a positive value of V D and the
capacitance value when the polarity of V D is reversed. Capacitance asymmetry is an important parameter in ADSL systems where the
protector often has no d.c. bias and the signal level is in the region of ±10 V.
Normal System Voltage Levels
The protector should not clip or limit the voltages that occur in normal system operation. For unusual conditions, such as ringing without the
line connected, some degree of clipping is permissible. Under this condition, about 10 V of clipping is normally possible without activating the
ring trip circuit.
Figure 10 allows the calculation of the protector VDRM value at temperatures below 25 °C. The calculated value should not be less than the
maximum normal system voltages. The TISP4265M3AJ, with a VDRM of 200 V, can be used for the protection of ring generators producing
100 V rms of ring on a battery voltage of -58 V (Th2 and Th3 in Figure 17). The peak ring voltage will be 58 + 1.414*100 = 199.4 V. However,
this is the open circuit voltage and the connection of the line and its equipment will reduce the peak voltage. In the extreme case of an
unconnected line, clipping the peak voltage to 190 V should not activate the ring trip. This level of clipping would occur at the temperature
when the VDRM has reduced to 190/200 = 0.95 of its 25 °C value. Figure 10 shows that this condition will occur at an ambient temperature of
-28 °C. In this example, the TISP4265M3AJ will allow normal equipment operation provided that the minimum expected ambient temperature
does not fall below -28 °C.
JESD51 Thermal Measurement Method
To standardize thermal measurements, the EIA (Electronic Industries Alliance) has created the JESD51 standard. Part 2 of the standard
(JESD51-2, 1995) describes the test environment. This is a 0.0283 m3 (1 ft3) cube which contains the test PCB (Printed Circuit Board)
horizontally mounted at the center. Part 3 of the standard (JESD51-3, 1996) defines two test PCBs for surface mount components; one for
packages smaller than 27 mm on a side and the other for packages up to 48 mm. The SMBJ measurements used the smaller 76.2 mm x
114.3 mm (3.0 “ x 4.5 “) PCB. The JESD51-3 PCBs are designed to have low effective thermal conductivity (high thermal resistance) and
represent a worst case condition. The PCBs used in the majority of applications will achieve lower values of thermal resistance, and can
dissipate higher power levels than indicated by the JESD51 values.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP4xxxM3AJ Overvoltage Protector Series
Typical Circuits
MODEM
TIP
WIRE
RING
FUSE
RING DETECTOR
R1a
Th3
HOOK SWITCH
TISP4350
PROTECTED
EQUIPMENT
Th1
D.C. SINK
E.G. LINE CARD
Th2
SIGNAL
RING
WIRE
TIP
AI6XBMA
R1b
AI6XBK
Figure 15. Protection Module
Figure 14. Modem Inter-Wire Protection
R1a
Th3
SIGNAL
Th1
Th2
R1b
AI6XBL
D.C.
Figure 16. ISDN Protection
TIP
WIRE
OVERCURRENT
PROTECTION
RING/TEST
PROTECTION
TEST
RELAY
RING
RELAY
SLIC
RELAY
S3a
R1a
Th3
S1a
SLIC
PROTECTION
Th4
S2a
SLIC
Th1
Th2
RING
WIRE
Th5
R1b
S3b
S1b
S2b
TISP6xxxx,
TISPPBLx,
1/2TISP6NTP2
C1
220 nF
TEST
EQUIPMENT
RING
GENERATOR
Figure 17. Line Card Ring/Test Protection
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
V BAT
AI6XBJ
TISP4xxxM3AJ Overvoltage Protector Series
MECHANICAL DATA
Recommended Printed Wiring Footprint
SMA Land Pattern
2.34
(. 092)
1.90
(.075)
2.16
(.085)
MILLIMETERS
DIMENSIONS ARE:
(INCHES)
MDXX BIC
Device Symbolization Code
Devices will be coded as below. As the device parameters are symmetrical, terminal 1 is not identified.
TISP4070M3AJ
TISP4080M3AJ
TISP4090M3AJ
Symbolization
Code
4070M3
4080M3
4090M3
TISP4095M3AJ
TISP4115M3AJ
TISP4125M3AJ
TISP4145M3AJ
TISP4165M3AJ
TISP4180M3AJ
TISP4200M3AJ
TISP4220M3AJ
TISP4240M3AJ
TISP4250M3AJ
TISP4265M3AJ
TISP4290M3AJ
TISP4300M3AJ
TISP4350M3AJ
TISP4360M3AJ
TISP4395M3AJ
4095M3
4115M3
4125M3
4145M3
4165M3
4180M3
4200M3
4220M3
4240M3
4250M3
4265M3
4290M3
4300M3
4350M3
4360M3
4395M3
Device
Carrier Information
For production quantities, the carrier will be embossed tape reel pack. Evaluation quantities may be shipped in bulk pack or embossed tape.
Carrier
Embossed Tape Reel Pack
Standard Quantity
5,000
“TISP” is a trademark of Bourns, Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Office.
“Bourns” is a registered trademark of Bourns, Inc. in the U.S. and other countries.
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.