Product Specification

 D0106LT‐33‐0604 VFD (Vacuum Fluorescent Display) RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] November 10, 2009
Vacuum Fluorescent Display
Specification
PART NUMBER:
D0106LT-33-0604
FEATURES: 6 Digits, 7-Segmented, Instrumentation
APPLICATION: Character Display (7-Segmented)
RATINGS: Below
Panel Length
Panel Height
Panel Thickness
P.L.
P.H.
P.T.
98.0
33.0
8.0
mm
mm
mm
Leads
Lead Pitch
Lead Out
L.P.
-
4.0
SIL
mm
Character Size
Character Height
Character Width
C.H.
C.W.
12.4
6.8
mm
mm
Outer Dimensions
Item
Symbol
Min.
Recommended
Max.
Unit
Filament Voltage
Peak Grid Voltage
Peak Anode Voltage
Duty
Cycle
Pulse Width
Operating Temperature
Storage Temperature
Ef
ec
eb
Du
3.4
-
3.8
26.0
26.0
1/7
4.2
33.0
33.0
-
Vac
Vp-p
Vp-p
-
tp
Topr
Tstg
-40
-50
200
-
+ 85
+ 95
uS
C
C
Color of Illumination
Green
-1-
D0106LT-33-0604
Electrical
Characteristics
Symbol
Test Condition
Min.
Typical
Max.
Unit
If
Ef = 3.8 Vac
eb = ec = 0
97.0
108.0
119.0
mAac
Anode Current
ib/1G~6G
-
Ef = 3.8 Vac
eb = 26.0 Vp-p
ec = 26.0 Vp-p
Du = 1/7
Tp = 200 uS
-
5.0
-
10.0
-
mAp-p
mAp-p
mAp-p
mAp-p
mAp-p
Grid Current
ic / 1G~6G
-
-
7.0
-
14.0
-
MAp-p
MAp-p
-
-
-
-
MAp-p
MAp-p
MAp-p
L(G)
-
343
(100)
686
(200)
-
cd/m2
fL
50
-
-
%
-4.0
-
-
Vdc
-2.0
-
-
Vdc
Item
Filament Current
Luminance
Lmin/Lmax
Luminance Ratio
Grid Cut-off Voltage
Ecco
Anode Cut-off Voltage
Ebco
Ef = 3.8 Vac
eb = 26.0 Vdc
Ef = 3.8 Vac
ec = 26.0 Vp-p
Du = 1/7
Tp = 200uS
-2-
Mechanical Drawing
D0106LT-33-0604
Display Pattern
D0106LT-33-0604
Grid Assignment
D0106LT-33-0604
Anode Connection
D0106LT-33-0604