D0106LT‐33‐0604 VFD (Vacuum Fluorescent Display) RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] November 10, 2009 Vacuum Fluorescent Display Specification PART NUMBER: D0106LT-33-0604 FEATURES: 6 Digits, 7-Segmented, Instrumentation APPLICATION: Character Display (7-Segmented) RATINGS: Below Panel Length Panel Height Panel Thickness P.L. P.H. P.T. 98.0 33.0 8.0 mm mm mm Leads Lead Pitch Lead Out L.P. - 4.0 SIL mm Character Size Character Height Character Width C.H. C.W. 12.4 6.8 mm mm Outer Dimensions Item Symbol Min. Recommended Max. Unit Filament Voltage Peak Grid Voltage Peak Anode Voltage Duty Cycle Pulse Width Operating Temperature Storage Temperature Ef ec eb Du 3.4 - 3.8 26.0 26.0 1/7 4.2 33.0 33.0 - Vac Vp-p Vp-p - tp Topr Tstg -40 -50 200 - + 85 + 95 uS C C Color of Illumination Green -1- D0106LT-33-0604 Electrical Characteristics Symbol Test Condition Min. Typical Max. Unit If Ef = 3.8 Vac eb = ec = 0 97.0 108.0 119.0 mAac Anode Current ib/1G~6G - Ef = 3.8 Vac eb = 26.0 Vp-p ec = 26.0 Vp-p Du = 1/7 Tp = 200 uS - 5.0 - 10.0 - mAp-p mAp-p mAp-p mAp-p mAp-p Grid Current ic / 1G~6G - - 7.0 - 14.0 - MAp-p MAp-p - - - - MAp-p MAp-p MAp-p L(G) - 343 (100) 686 (200) - cd/m2 fL 50 - - % -4.0 - - Vdc -2.0 - - Vdc Item Filament Current Luminance Lmin/Lmax Luminance Ratio Grid Cut-off Voltage Ecco Anode Cut-off Voltage Ebco Ef = 3.8 Vac eb = 26.0 Vdc Ef = 3.8 Vac ec = 26.0 Vp-p Du = 1/7 Tp = 200uS -2- Mechanical Drawing D0106LT-33-0604 Display Pattern D0106LT-33-0604 Grid Assignment D0106LT-33-0604 Anode Connection D0106LT-33-0604