T PL IA N M Features Applications ■ Mini-compact size: 4 mm diameter, ■ Industrial equipment/electronics *R oH S CO 4.2 mm length ■ Telecommunications electronics ■ Surface mount device ■ Consumer electronics ■ High voltage range ■ High insulation resistance ■ RoHS compliant* ■ UL Recognized 2087 Series High Voltage Mini-2-Electrode Gas Discharge Tube Characteristics Test Methods per ITU-T (CCITT) K.12 and IEC 61643-311. Model No. Characteristic DC Sparkover ±20 % @ 100 V/s Impulse Sparkover 100 V/µs 1000 V/µs (1) 2087-80 2087-100 2087-120 2087-150 2087-180 2087-200 800 V 1000 V 1200 V 1500 V 1800 V 2000 V < 1300 V < 1400 V < 1500 V < 1600 V < 1700 V < 1800 V < 2000 V < 2100 V < 2500 V < 2600 V < 2700 V < 2800 V (1) Impulse Sparkover voltage is defined as typical values of distribution. Insulation Resistance (IR) (2) ............................ 250/500 Vdc......................................................> 1 GΩ Glow Voltage ................................................... 10 mA................................................................~ 60 V Arc Voltage ...................................................... 1 A .....................................................................~ 15 V Glow-Arc Transition Current .......................................................................................................< 1 A Capacitance..................................................... 1 MHz ...............................................................< 0.5 pF Impulse Discharge Current .............................. 3,000 A, 8/20 µs ................................................ 1 operation 2,000 A, 8/20 µs ................................................ 10 operations Alternating Discharge Current 2 Arms, 50 Hz, 1 second................................... 1 operation min. 4 Arms, 50 Hz, 9 cycles .................................... 1 operation min. Impulse Life ..................................................... 100 A, 10/1000 µs .............................................> 100 operations Operating Temperature............................................................................................................... -30 to +85 °C Storage Temperature .................................................................................................................. -40 to +115 °C Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21 Notes: (2) Insulation Resistance measured at 500 V for GDTs with >1000 V DCBD. • UL Recognized component: UL File E313168. • At delivery AQL 0.65 Level II, DIN ISO 2859. • Bourns recommends reflowing surface mount devices per IPC/JEDEC J-STD-020 rev D. Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 2087 Series High Voltage Mini-2-Electrode Gas Discharge Tube Surge Protector Product Dimensions Recommended Pad Layout 4.0 ± 0.2 (.157 ± .008) 3.5 (.138) 4.0 ± 0.2 (.157 ± .008) 4.0 ± 0.2 (.157 ± .008) 5.0 (.197) 1.3 (.051) 0.5 ± 0.1 (.020 ± .004) DIMENSIONS: MM (INCHES) Packaging Specifications How to Order The Model 2087-xxx-SM ships standard reelpack (-RP), 900 pieces per reel, 2,700 pieces per box. Reel is 13 inches in diameter. 4.0 ± 0.1 (.157 ± .004) 1.75 ± 0.1 (.069 ± .004) DIA. 1.55 ± 0.05 (.061 ± .002) 4.6 ± 0.1 (.181 ± .004) 16.0 ± 0.3 (.630 ± .012) 7.5 ± 0.1 (.295 ± .004) 12.0 ± 0.1 (.472 ± .004) DIMENSIONS: 2087 - xxx - SM - RP LF Model Number Designator Voltage (Divided by 10) 80 = 800 V 100 = 1000 V 120 = 1200 V 150 = 1500 V 180 = 1800 V 200 = 2000 V Surface Mount Packaging RP = Reelpack (900 pcs./13 “ reel) RoHS Compliancy LF = RoHS Compliant Product 0.5 ± 0.05 (.020 ± .002) MM (INCHES) REV. C 08/15 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.