2097

T
PL
IA
N
M
CO
*R
oH
S
Features
Applications
■ Size: 11.8 mm diameter, 17.5 mm length
■ Industrial equipment/electronics
■ High power rating
■ Telecommunications electronics
■ High voltage range
■ RoHS compliant*
■
UL Recognized**
2097 Series High-Voltage 2-Electrode Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12 and IEC 61643-311.
Model No.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
(1)
2097-100**
2097-120
2097-140
2097-160
2097-200
2097-220
1000 V
1200 V
1400 V
1600 V
2000 V
2200 V
< 1500 V
< 1700 V
< 1800 V
< 2000 V
< 2000 V
< 2200 V
< 2300 V
< 2500 V
< 2600 V
< 2700 V
< 2700 V
< 2800 V
(1)
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) (2) ............................ 500/1000 Vdc....................................................> 10 GΩ
Glow Voltage ................................................... 10 mA................................................................~ 60 V
Arc Voltage ...................................................... 1 A .....................................................................~ 15 V
Glow-Arc Transition Current .......................................................................................................< 1 A
Capacitance..................................................... 1 MHz ...............................................................< 1.0 pF
Impulse Discharge Current .............................. 25,000 A, 8/20 µs .............................................. 1 operation
20,000 A, 8/20 µs .............................................. 5 operations
Alternating Discharge Current
20 Arms, 50 Hz, 1 second................................. 1 operation min.
120 Arms, 50 Hz, 9 cycles ................................ 1 operation min.
Impulse Life ..................................................... 500 A, 10/1000 µs .............................................> 400 operations
Operating Temperature............................................................................................................... -30 to +85 °C
Storage Temperature .................................................................................................................. -40 to +115 °C
Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21
Notes:
(2)
Insulation Resistance measured at 1000 V for GDTs with >2000 V DCBD.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
** UL Recognized components, UL File E313168. Model 2097-100 is not UL Recognized.
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
2097 Series High-Voltage 2-Electrode Gas Discharge Tube
Product Dimensions
32.0 ± 1.0
(1.260 ± .039)
7.3 ± 0.3
(.287 ± .012)
17.4 ± 0.5
(.685 ± .020)
5.8 ± 0.2
(.228 ± .008)
11.8 ± 0.2
(.465 ± .008)
DIA.
DIMENSIONS:
MM
(INCHES)
M3
Packaging Specifications
Model 2097 ships standard bulk, 35 pcs. per tray; 3 trays per box
(105 units).
How to Order
2097 - xxx - D LF
Model Number Designator
Voltage (Divided by 10)
100 = 1000 V
120 = 1200 V
140 = 1400 V
160 = 1600 V
200 = 2000 V
220 = 2200 V
Contact Terminals
D = M3
RoHS Compliancy
LF = RoHS Compliant Product
REV. E 08/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.