JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50MS-211 MATRIX SWITCH Frequency Range DC-6000 MHz Configuration 4 x 8 Blocking Matrix (See block diagram 092-5778) (Unused input ports are reflective) (Unused output ports are reflective) (all ports are bi-directional) (the ADMIN password is located on rear panel) Startup/Default States (configurable) All ports off at startup (see MATRIX command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) All of these default settings can be changed by user. Unit can be configured for up to 12 Ethernet users. Enclosure Type 19 inch rack mount @ 4RU high Impedance 50 Ohms nominal VSWR 1.5:1 maximum Insertion Loss 1 dB maximum 2 dB maximum Isolation 70 dB minimum 65 dB minimum RF Input Power 1 Watt average Switching Speed 20 milliseconds (after command is received and processed) (3 milliseconds typical processing time) Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) DC-2500 MHz 2500-6000 MHz DC-4000 MHz 4000-6000 MHz --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50MS-211 MATRIX SWITCH Remote Commands Matrix Commands: Matrix, Set Input, Set Output, Read Input, Read Output, Read All Inputs, Read All Outputs, Read Matrix Paths System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector SMA female AC Supply 100-240 VAC @ 47-63 Hz 2 Amp 5x20mm "Slo-Blo" AC fuse Littelfuse #215-002, JFW #025-021 Operating Temperature Range 0º to +70º C Physical Size See outline drawing 092-5403 ECR/ECN # DATE REV 05/03/2007 Page 2 of 2 APPR / DATE ECR/ECN # DATE REV APPR / DATE TRS 05/03/2007 16179 08/07/2008 C TRS 08/07/2008 15800 05/01/2008 A TRS 05/01/2008 21887 09/06/2012 D TRS 09/06/2012 15916 05/28/2008 B TRS 05/28/2008 24239 07/15/2015 E TRS 07/15/2015 JFW FORM E-7-F REV F