JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50MS-305 MATRIX SWITCH Frequency Range DC-6 GHz Configuration 18 x 4 Blocking Matrix (See block diagram 092-7410) (maximum of 4 active RF paths) (inputs & outputs are self-terminating*) (all ports are bi-directional) (the ADMIN password is located on rear panel) Startup/Default States (configurable) All ports off at startup (see MATRIX command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) All of these default settings can be changed by user. Unit can be configured for up to 12 Ethernet users. Enclosure Type 19 inch rack mount @ 4RU high Impedance 50 Ohms nominal VSWR 1.2:1 typical 1.3:1 typical 1.4:1 typical DC-2GHz 2-4GHz 4-6GHz 1.5:1 maximum 1.6:1 maximum 1.7:1 maximum DC-2GHz 2-4GHz 4-6GHz Insertion Loss 2.5 dB typical @ 6GHz 3.0 dB maximum DC-6GHz Isolation Input to Input - 65 dB minimum Input to Output - 65 dB minimum Output to Output - 65 dB minimum RF Input Power +30 dBm average (Hot Switched) Switching Speed 20 milliseconds Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50MS-305 MATRIX SWITCH Remote Commands Matrix Commands: Matrix, Set Input, Set Output, Read Input, Read Output, Read All Inputs, Read All Outputs, Read Matrix Paths System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector SMA female AC Supply 100-240 VAC @ 47-63 Hz 2 Amp 5x20mm "Slo-Blo" AC fuse Littelfuse #215-002, JFW #025-021 Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-7409 * The unused inputs and outputs are terminated when the unit is powered only. If AC power is lost, all inputs and outputs are open. ECR/ECN # DATE REV 07/17/2012 24239 Page 2 of 2 07/15/2015 APPR / DATE ECR/ECN # BAC 08/22/2012 A TRS 07/15/2015 JFW FORM E-7-F REV F DATE REV APPR / DATE