JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75PA-103 PROGRAMMABLE ATTENUATOR ASSEMBLY Frequency Range 5-1650 MHz Configuration Single individually controlled solid-state programmable attenuator Enclosure Type Benchtop Impedance 75 Ohms nominal Attenuation Range 0-63 dB in 1 dB steps Startup/Default States (configurable) Attenuators to 63dB at startup (see ATTEN command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) Jog speed 5 (see JOG SPEED command) All of these default settings can be changed by user. Unit can be configured for up to 12 Ethernet users. VSWR 1.7:1 maximum 1.5:1 typical Attenuation Accuracy ± 0.5 dB or 3% of programmed (whichever is greater) (guaranteed monotonic) Insertion Loss 2.0 3.0 4.0 4.5 RF Input Power +10 dBm Switching Speed 10 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115,200 Baud) Manual Control Momentary Lever Actuator Switches with 7-Segment LED Displays (tap to step, hold to jog) (jog speed range is 0-10) (jog speed set to 0 will disable all levers) dB dB dB dB typical typical typical maximum @ 5MHz @ 1000MHz @ 1650MHz 5-1650MHz --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75PA-103 PROGRAMMABLE ATTENUATOR ASSEMBLY Remote Commands Attenuator Control Commands: Atten, Set Attenuator, Read Attenuator, Fade Attenuator System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector F female AC Supply 100-240 VAC @ 47-63 Hz Operating Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-8559 ECR/ECN # DATE 02/22/2016 Page 2 of 2 REV APPR / DATE ECR/ECN # TRS 02/22/2016 JFW FORM E-7-F REV F DATE REV APPR / DATE