Specs

SPECIFICATION SHEET
JFW MODEL 75PA-088
PROGRAMMABLE ATTENUATOR ASSEMBLY
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
Frequency Range
DC-1000 MHz
Configuration
Two individually controlled
electromechanical programmable attenuators
Enclosure Type
Benchtop
Impedance
75 Ohms nominal
Attenuation Range
0-95.5 dB in 0.5 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command
Prompts off (see PROMPT command)
VSWR
1.5:1 maximum
Attenuation Accuracy
(guaranteed monotonic)
± 0.2 dB or 2% of programmed
(whichever is greater)
Insertion Loss
3.0 dB maximum
RF Input Power
0.5 Watts average
Switching Speed
6 milliseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse#215-002, JFW#025-021
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
Remote Commands
Attenuator Control Commands:
Atten, Set Attenuator, Read Attenuator, Set All
Attenuators, Read All Attenuators, Read All
Extended, Block, Set Block, Read Block, Read All
Blocks
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot,
Uptime, Prompt
RF Connector
F female
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 75PA-088
PROGRAMMABLE ATTENUATOR ASSEMBLY
Operating Temperature
Range
0ºC to +50ºC
Physical Size
See outline drawing 092-8245
ECR/ECN #
DATE
02/19/2015
Page 2 of 2
REV
APPR / DATE
ECR/ECN #
CLK 02/19/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE