Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-716
LC HANDOVER TEST SYSTEM
Frequency Range
2-6 GHz
Configuration
8 X 2 LC Handover Test System
(See block diagram 092-7337)
Enclosure Type
19 inch rack mount @ 2RU high
Impedance
50 Ohms nominal
Attenuation Range
0-95 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command
Prompts off (see PROMPT command)
VSWR
1.6:1 maximum
Attenuation Accuracy
(guaranteed monotonic)
± 0.50 dB
1-3 dB
± 0.75 dB
4-7 dB
± 1.00 dB
8-11 dB
± 1.25 dB or 4%
12-95 dB
(whichever is greater)
Insertion Loss
27 dB maximum
22 dB typical @ 2 GHz
25 dB typical @ 6 GHz
Isolation
28 dB minimum (Ant 1-8 to Ant 1-8)
18 dB minimum (J1 to J2)
RF Input Power
+20 dBm average
+25 dBm (no damage)
Switching Speed
1 microsecond typical
(after command is received & processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse#215-002, JFW#025-021
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-716
LC HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Attenuator, Read Attenuator, Set
All Attenuators, Read All Attenuators, Read
All Extended, Fade Attenuator, Variable
Attenuator Handover, Block, Set Block, Read
Block, Read All Blocks, Fade Block, Variable
Block Handover
System Commands:
Help, Identification, Store, Recall, Pause,
Net, Serial, Close, Disconnect, MOTD, Date,
Message, Restrict, IDENT, Name, Show Users,
Reboot, Uptime, Prompt
RF Connector
N or SMA female
Operating Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-7336
ECR/ECN #
DATE
REV
04/26/2012
Page 2 of 2
APPR / DATE
ECR/ECN #
CLK 04/26/2012
22684
03/27/2013
A
CLK 03/27/2013
24239
07/03/2014
B
TRS 07/03/2014
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE