Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-799
LC HANDOVER TEST SYSTEM
Frequency Range
700-3000 MHz
Configuration
6 x 1 LC Handover Test System
(See block diagram 092-5640)
Enclosure Type
19 inch rack mount @ 2RU high
Impedance
50 Ohms nominal
VSWR
1.7:1 maximum
1.5:1 typical
Attenuation Range
0-127 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command
Prompts off (see PROMPT command)
Attenuation Accuracy
(guaranteed monotonic)
± 0.7 dB or 2% maximum
± 0.5 dB or 2% typical
(whichever is greater)
Insertion Loss
20 dB maximum
14.2 dB typical @ 700 MHz
17.8 dB typical @ 3000 MHz
Isolation
30 dB minimum IN 1-6 to IN 1-6
RF Input Power
+20 dBm average
+30 dBm (no damage)
Switching Speed
5 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
0.4 Amps @ 120 VAC nominal
0.2 Amps @ 240 VAC nominal
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse#215-002, JFW#025-021
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-799
LC HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Attenuator, Read Attenuator, Set
All Attenuators, Read All Attenuators, Read
All Extended, Fade Attenuator, Variable
Attenuator Handover, Block, Set Block, Read
Block, Read All Blocks, Fade Block, Variable
Block Handover
System Commands:
Help, Identification, Store, Recall, Pause,
Net, Serial, Close, Disconnect, MOTD, Date,
Message, Restrict, IDENT, Name, Show Users,
Reboot, Uptime, Prompt
RF Connector
SMA or N female
Operating Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-6453
ECR/ECN #
DATE
05/20/2013
Page 2 of 2
REV
APPR / DATE
ECR/ECN #
CLK 05/20/2013
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE