HBA2 Series 20130814A

Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
Features
7 pin SIP package
Input / Output Isolation Voltage: 6.4kVDC
High Efficiency
Lead Free Design, RoHS Compliant
Operating temperature: -40°C to +85°C
Optional Reinforced Isolation 8kVDC
Safety Standard / Approval : IEC / EN 60950-1
IEC / EN 60601-1
Applications
These converters are well suitable for battery operated
equipment, measurement equipment, telecom, wireless
network, Industry control system, everywhere where
isolated, tightly regulated voltages and compact size are
required.
Technical Specification
Model
Number
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
Output
Output
Capacitive
(2)
Input Current (mA)
Input Voltage
Reinforced
Eff .
(3)
Voltage Current (mA)
Load, max.
Isolation 8kVDC Range(V)
(%)
(V)
(uF)
Full Load No Load Full Load
HBA2-05S0H6
HBA2-05S0H8
3.3
600
550
76
3300
HBA2-05S1H6
HBA2-05S1H8
5
400
541
78
1200
HBA2-05SBH6
HBA2-05SBH8
7.2
278
526
80
1200
HBA2-05SAH6
HBA2-05SAH8
9
222
513
82
1200
HBA2-05S2H6
HBA2-05S2H8
12
167
513
82
680
HBA2-05S3H6
HBA2-05S3H8
15
132
513
82
680
HBA2-05D0H6
HBA2-05D0H8
±3.3
±300
535
78
±1500
HBA2-05D1H6
HBA2-05D1H8
±5
±200
526
80
±470
HBA2-05DBH6
HBA2-05DBH8
±7.2
±139
526
80
±470
HBA2-05DAH6
HBA2-05DAH8
±9
±111
519
81
±470
HBA2-05D2H6
HBA2-05D2H8
±12
±85
519
81
±330
HBA2-05D3H6
HBA2-05D3H8
±15
±66
513
82
±330
HBA2-12S0H6
HBA2-12S0H8
3.3
600
223
78
3300
4.5 ~ 5.5
Nominal: 5
70
HBA2-12S1H6
HBA2-12S1H8
5
400
219
80
1200
HBA2-12SBH6
HBA2-12SBH8
7.2
278
213
82
1200
HBA2-12SAH6
HBA2-12SAH8
9
222
211
83
1200
HBA2-12S2H6
HBA2-12S2H8
12
167
211
83
680
HBA2-12S3H6
15
132
211
83
680
HBA2-12D0H6
10.8 ~ 13.2
12
Nominal:
HBA2-12D0H8
±3.3
±300
217
80
±1500
HBA2-12D1H6
HBA2-12D1H8
±5
±200
213
82
±470
HBA2-12DBH6
HBA2-12DBH8
±7.2
±139
211
83
±470
HBA2-12DAH6
HBA2-12DAH8
±9
±111
208
84
±470
HBA2-12D2H6
HBA2-12D2H8
±12
±85
208
84
±330
HBA2-12D3H6
HBA2-12D3H8
±15
±66
206
85
HBA2-12S3H8
[email protected]
www.bothhandusa.com
30
Rev:20130522A
±330
Page 1 of 4
Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
Model
Number
HBA2-15S0H6
Reinforced
Input Voltage
Isolation 8kVDC Range(V)
HBA2-15S0H8
Output
Voltage
(V)
Output
Input Current (mA)
Current (mA)
Full Load No Load Full Load
3.3
600
Eff .(2)
(%)
Capacitive
(3)
Load, max.
(uF)
178
78
3300
HBA2-15S1H6
HBA2-15S1H8
5
400
175
80
1200
HBA2-15SBH6
HBA2-15SBH8
7.2
278
171
82
1200
HBA2-15SAH6
HBA2-15SAH8
9
222
169
83
1200
HBA2-15S2H6
HBA2-15S2H8
12
167
167
84
680
HBA2-15S3H6
13.5 ~ 16.5
Nominal:
15
HBA2-15D0H8
15
132
165
85
680
±3.3
±300
174
80
±1500
HBA2-15D0H6
HBA2-15S3H8
25
HBA2-15D1H6
HBA2-15D1H8
±5
±200
171
82
±470
HBA2-15DBH6
HBA2-15DBH8
±7.2
±139
169
83
±470
HBA2-15DAH6
HBA2-15DAH8
±9
±111
167
84
±470
HBA2-15D2H6
HBA2-15D2H8
±12
±85
167
84
±330
HBA2-15D3H6
HBA2-15D3H8
±15
±66
165
85
±330
HBA2-24S0H6
HBA2-24S0H8
3.3
600
111
78
3300
HBA2-24S1H6
HBA2-24S1H8
5
400
110
80
1200
HBA2-24SBH6
HBA2-24SBH8
7.2
278
113
78
1200
HBA2-24SAH6
HBA2-24SAH8
9
222
113
78
1200
HBA2-24S2H6
HBA2-24S2H8
12
167
113
78
680
HBA2-24S3H6
HBA2-24D0H6
HBA2-24S3H8 21.6 ~ 26.4
HBA2-24D0H8 Nominal: 24
HBA2-24D1H6
15
132
111
79
680
±3.3
±300
113
77
±1500
HBA2-24D1H8
±5
±200
110
80
±470
HBA2-24DBH6
HBA2-24DBH8
±7.2
±139
114
77
±470
HBA2-24DAH6
HBA2-24DAH8
±9
±111
113
78
±470
HBA2-24D2H6
HBA2-24D2H8
±12
±85
110
80
±330
HBA2-24D3H6
HBA2-24D3H8
±15
±66
111
79
±330
20
Input Specifications
4.5~5.5V
5V nominal input
Input voltage
12V nominal input
10.8~13.2V
15V nominal input
13.5~16.5V
24V nominal input
21.6~26.4V
Capacitor
Input filter
Environmental Specifications
-40°C to +85°C
Operating ambient temperature
+95°C
Maximum case temperature
-55°C to +125°C
Storage temperature range
95% RH max.
Relative humidity
Output Specifications
2 Watts max.
Output power
Voltage accuracy
[email protected]
±5% max.
Nominal Vin and full load
www.bothhandusa.com
Rev:20130522A
Page 2 of 4
Bothhand USA
Voltage balance
Isolated DC-DC Converters
HBA2 Series -- 2Watt
±1% max.
Dual output
Minimum load
Line regulation
0A
±1.5% max.
For Vin change of 1%
10% max.
Load Regulation
10% load to full load
15% max.
(5Vout models)
20% max. (3.3Vout models)
Ripple and Noise (20MHz Bandwidth)
200mVp-p max.
Maximum capacitive load
See table
Output short circuit protection
1 second
General Specifications
Efficiency
Nominal input and full load
Isolation voltage
Input to output
Isolation resistance
500VDC
See table
6400VDC (1 second)
10GΩ min.
Isolation capacitance
10pF max.
Switching frequency
80kHz max.
6
Reliability, calculated MTBF
2×10 Hrs
Physical Specifications
Case material
Plastic (UL94 V-0)
Potting material
Epoxy (UL94 V-0)
0.77 × 0.50 × 0.39 Inch
Dimensions
(19.5 ×12.5 × 9.8 mm)
Weight
4.3g (0.15oz) typ.
Note
1. Io below this value will not damage these converters, however, they may not meet all listed specifications.
2. Typical value, tested at nominal input and full load.
3. For each output.
[email protected]
www.bothhandusa.com
Rev:20130522A
Page 3 of 4
Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
Mechanical Dimensions
Single output
19.50
(0.77)
16.50
(0.65)
10.40
(0.41)
5.00
(0.20)
8.50
(0.33)
HBAX-XXSXHX
Pb
2.54
(0.10)
Date Code
12.50
(0.50)
9.80
(0.39)
Printed
Face
4.10
(0.162)
7.62
(0.30)
15.24
(0.60)
0.50
(0.02)
Pin
1
2
5
6
7
0.50
(0.02)
0.25
(0.01)
2.40
(0.094)
2.36
(0.093)
1.90
(0.075)
Dual output
5.00
(0.20)
8.50
(0.33)
HBAX-XXDXHX
Pb
2.54
(0.10)
Date Code
10.40
(0.41)
Unit: mm (inch)
Tolerance: XX.XX ±0.25 (±0.01)
9.80
(0.39)
19.50
(0.77)
16.50
(0.65)
12.50
(0.50)
Pin Assignment
Single
Dual
+Vin
+Vin
-Vin
-Vin
-Vout
-Vout
No pin
Common
+Vout
+Vout
Printed
Face
4.10
(0.162)
7.62
(0.30)
15.24
(0.60)
0.50
(0.02)
0.50
(0.02)
0.25
(0.01)
2.40
(0.094)
1.90
(0.075)
2.36
(0.093)
Specifications subject to change without notice.
[email protected]
www.bothhandusa.com
Rev:20130522A
Page 4 of 4
Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
Test Configurations
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
A
DC
Power Supply
DC/DC
converter
V
V
Load
◎DC Power Supply: It offers a wide voltage and current range precisely.
◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A
2 ranges+(0.3% rdg + 2 digits).
◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits).
◎Load: At full load.
◎Wires: The resistance of the wires must be small.
1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range (2:1 and 4:1)。
EX: Narrow input voltage range(±10%)
5V nominal input 4.5~5.5V
12V nominal input 10.8~13.2V
24V nominal input 21.6~26.4V
Wide input voltage range 2:1
5V nominal input 12V nominal input 24V nominal input 48V nominal input 4.5~9V
9~18V
18~36V
36~75V
Wide input voltage range 4:1 (W)
24V nominal input 9~36V
48V nominal input 18~75V
2. Input power :
Pin = Vin x Iin
Vin:Input voltage
Iin:Input current
Pout = Vout x Iout
Vout:Output voltage
Iout:Output current
3. Output power :
4. Efficiency :
Efficiency =
Pout
Pin
x100%
Pout: Output power
Pin: Input power
5. Voltage accuracy:
│
│Vout-Vout(nominal)│
Vout
[email protected]
x100%
Vout:Output voltage
Vout(nominal):Nominal output voltage
www.bothhandusa.com
Rev:20130522A
Page 5 of 4
Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
││││
││││
6. Line regulation: (1) Wide input voltage range and regulated output voltage series.
│
│Vout(LL)-Vout(HL)│
Vout(LL)
LL: Low Line input voltage
HL: High Line input voltage
x100%
(2) Narrow input voltage range(±10%)and unregulated output voltage series.
Line regulation=
Δ Vout
Δ Vin
ΔVout = Vout(+10%)-Vout(-10%) x100%
Vout
Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load
Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load
Vout:Output voltage at Vin = Vin(nominal)&full load
ΔVin = Vin(+10%)-Vin(-10%) x100%
Vin(nominal)
Vin(+10%):Input voltage = 1.1xVin(nominal)
Vin(-10%):Input voltage = 0.9xVin(nominal)
Vin(nominal):Nominal Input voltage
7. Load regulation :
│ x100%
│Vout(FL)-Vout(NL)│
Vout(FL)
Vout(FL): Output voltage at full load
Vout(NL): Output voltage at 25% full load or 10% full load
8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz.
Ripple&Noise
Noise
Ripple
[email protected]
www.bothhandusa.com
Rev:20130522A
Page 6 of 4
Isolated DC-DC Converters
HBA2 Series -- 2Watt
Bothhand USA
Output Ripple&Noise measurement test circuit: as shown below.
Copper strip
DC/DC
converter
Co
Oscilloscope
Load
Copper strip
Co: usually 0.47uF.
9. Temperature derating curve: The DC-DC converter will operate over a wider temperature range if less power is
Output Power (%)
drawn from the output and the device is already running. The temperature derating curve shows the operating
power-temperature range. As shown below.
Ambient Temp.TA (℃)
10. Switching frequency: The nominal operating frequency of the DC-DC converters.
11. Input to output isolation: The dielectric breakdown strength test between input and output circuits. This is the
isolation voltage the device is capable of withstanding for a specified time, usually 1 second or 1 minute.
[email protected]
www.bothhandusa.com
Rev:20130522A
Page 7 of 4