Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA Features 7 pin SIP package Input / Output Isolation Voltage: 6.4kVDC High Efficiency Lead Free Design, RoHS Compliant Operating temperature: -40°C to +85°C Optional Reinforced Isolation 8kVDC Safety Standard / Approval: IEC / EN 60950-1 EC / EN 60601-1 Applications These converters are well suitable for battery operated equipment, measurement equipment, telecom, wireless network, Industry control system, everywhere where isolated, tightly regulated voltages and compact size are required. Technical Specification Model Number All specifications are typical at nominal input, full load and 25°C unless otherwise stated. Output Output Capacitive (2) Input Current (mA) Input Voltage Reinforced Eff . (3) Voltage Current (mA) Load, max. Isolation 8kVDC Range(V) (%) (V) (uF) Full Load No Load Full Load HBA1-05S0H6 HBA1-05S0H8 3.3 303 278 76 3300 HBA1-05S1H6 HBA1-05S1H8 5 200 271 78 2200 HBA1-05SBH6 HBA1-05SBH8 7.2 140 273 78 1000 HBA1-05SAH6 HBA1-05SAH8 9 111 263 80 1000 HBA1-05S2H6 HBA1-05S2H8 12 84 262 81 470 HBA1-05S3H6 HBA1-05S3H8 15 66 253 82 470 HBA1-05D0H6 HBA1-05D0H8 ±3.3 ±151 281 75 ±2200 HBA1-05D1H6 HBA1-05D1H8 ±5 ±100 271 78 ±1000 HBA1-05DBH6 HBA1-05DBH8 ±7.2 ±70 273 78 ±470 HBA1-05DAH6 HBA1-05DAH8 ±9 ±55 264 79 ±470 HBA1-05D2H6 HBA1-05D2H8 ±12 ±41 259 80 ±220 HBA1-05D3H6 HBA1-05D3H8 ±15 ±33 258 81 ±220 HBA1-12S0H6 HBA1-12S0H8 3.3 303 116 76 3300 4.5 ~ 5.5 Nominal: 5 35 HBA1-12S1H6 HBA1-12S1H8 5 200 113 78 2200 HBA1-12SBH6 HBA1-12SBH8 7.2 140 114 78 1000 HBA1-12SAH6 HBA1-12SAH8 9 111 110 80 1000 HBA1-12S2H6 HBA1-12S2H8 12 84 110 81 470 HBA1-12S3H6 15 66 106 82 470 HBA1-12D0H6 10.8 ~ 13.2 12 Nominal: HBA1-12D0H8 ±3.3 ±151 117 75 ±2200 HBA1-12D1H6 HBA1-12D1H8 ±5 ±100 113 78 ±1000 HBA1-12DBH6 HBA1-12DBH8 ±7.2 ±70 114 78 ±470 HBA1-12DAH6 HBA1-12DAH8 ±9 ±55 110 79 ±470 HBA1-12D2H6 HBA1-12D2H8 ±12 ±41 108 80 ±220 HBA1-12D3H6 HBA1-12D3H8 ±15 ±33 108 81 HBA1-12S3H8 [email protected] www.bothhandusa.com 30 Rev:20120814A ±220 Page 1 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA Model Number HBA1-15S0H6 Reinforced Input Voltage Isolation 8kVDC Range(V) HBA1-15S0H8 Output Voltage (V) Output Input Current (mA) Current (mA) Full Load No Load Full Load 3.3 303 Eff .(2) (%) Capacitive (3) Load, max. (uF) 93 76 3300 HBA1-15S1H6 HBA1-15S1H8 5 200 91 78 2200 HBA1-15SBH6 HBA1-15SBH8 7.2 140 91 78 1000 HBA1-15SAH6 HBA1-15SAH8 9 111 88 80 1000 HBA1-15S2H6 HBA1-15S2H8 12 84 88 81 470 HBA1-15S3H6 13.5 ~ 16.5 Nominal: 15 HBA1-15D0H8 15 66 85 82 470 ±3.3 ±151 94 75 ±2200 HBA1-15D0H6 HBA1-15S3H8 25 HBA1-15D1H6 HBA1-15D1H8 ±5 ±100 91 78 ±1000 HBA1-15DBH6 HBA1-15DBH8 ±7.2 ±70 91 78 ±470 HBA1-15DAH6 HBA1-15DAH8 ±9 ±55 88 79 ±470 HBA1-15D2H6 HBA1-15D2H8 ±12 ±41 87 80 ±220 HBA1-15D3H6 HBA1-15D3H8 ±15 ±33 86 81 ±220 HBA1-24S0H6 HBA1-24S0H8 3.3 303 58 76 3300 HBA1-24S1H6 HBA1-24S1H8 5 200 57 78 2200 HBA1-24SBH6 HBA1-24SBH8 7.2 140 57 78 1000 HBA1-24SAH6 HBA1-24SAH8 9 111 54 80 1000 HBA1-24S2H6 HBA1-24S2H8 12 84 55 81 470 HBA1-24S3H6 HBA1-24D0H6 HBA1-24S3H8 21.6 ~ 26.4 HBA1-24D0H8 Nominal: 24 HBA1-24D1H6 15 66 53 82 470 ±3.3 ±151 59 75 ±2200 HBA1-24D1H8 ±5 ±100 57 78 ±1000 HBA1-24DBH6 HBA1-24DBH8 ±7.2 ±70 57 78 ±470 HBA1-24DAH6 HBA1-24DAH8 ±9 ±55 55 79 ±470 HBA1-24D2H6 HBA1-24D2H8 ±12 ±41 54 80 ±220 HBA1-24D3H6 HBA1-24D3H8 ±15 ±33 54 81 ±220 20 Input Specifications 4.5~5.5V 5V nominal input Input voltage 12V nominal input 10.8~13.2V 15V nominal input 13.5~16.5V 24V nominal input 21.6~26.4V Capacitor Input filter Environmental Specifications -40°C to +85°C Operating ambient temperature +95°C Maximum case temperature -55°C to +125°C Storage temperature range 95% RH max. Relative humidity Output Specifications 1 Watts max. Output power Voltage accuracy [email protected] ±5% max. Nominal Vin and full load www.bothhandusa.com Rev:20120814A Page 2 of 7 Bothhand USA Voltage balance Isolated DC-DC Converters HBA1 Series -- 1Watt ±1% max. Dual output Minimum load 0A Line regulation For Vin charge of 1% Load Regulation 10% load to full load ±1.5% max. 10% max. 15% max. (3.3&5Vout models) 150mVp-p max. Ripple and Noise (20MHz Bandwidth) Maximum capacitive load See table Output short circuit protection 1 second General Specifications Efficiency Nominal input and full load Isolation voltage Input to output Isolation resistance 500VDC See table 6400VDC (1 second) 15GΩ min. Isolation capacitance 10pF max. Switching frequency 80kHz max. 6 Reliability, calculated MTBF 2×10 Hrs Physical Specifications Case material Plastic (UL94 V-0) Potting material Epoxy (UL94 V-0) 0.77 × 0.50 × 0.39 Inch Dimensions (19.5 ×12.5 × 9.8 mm) Weight 4.3g (0.15oz) typ. Note 1. Io below this value will not damage these converters, however, they may not meet all listed specifications. 2. Typical value, tested at nominal input and full load. 3. For each output. [email protected] www.bothhandusa.com Rev:20120814A Page 3 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA Mechanical Dimensions Single output 19.50 (0.77) 16.50 (0.65) 10.40 (0.41) 5.00 (0.20) 8.50 (0.33) HBAX-XXSXHX Pb 2.54 (0.10) Date Code 12.50 (0.50) 9.80 (0.39) Printed Face 4.10 (0.162) 7.62 (0.30) 15.24 (0.60) 0.50 (0.02) Pin 1 2 5 6 7 0.50 (0.02) 0.25 (0.01) 2.40 (0.094) 2.36 (0.093) 1.90 (0.075) Dual output 5.00 (0.20) 8.50 (0.33) HBAX-XXDXHX Pb 2.54 (0.10) Date Code 10.40 (0.41) Unit: mm (inch) Tolerance: XX.XX ±0.25 (±0.01) 9.80 (0.39) 19.50 (0.77) 16.50 (0.65) 12.50 (0.50) Pin Assignment Single Dual +Vin +Vin -Vin -Vin -Vout -Vout No pin Common +Vout +Vout Printed Face 4.10 (0.162) 7.62 (0.30) 15.24 (0.60) 0.50 (0.02) 0.50 (0.02) 0.25 (0.01) 2.40 (0.094) 1.90 (0.075) 2.36 (0.093) Specifications subject to change without notice. [email protected] www.bothhandusa.com Rev:20120814A Page 4 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA Test Configurations All specifications are typical at nominal input, full load and 25°C unless otherwise stated. A A DC Power Supply DC/DC converter V V Load ◎DC Power Supply: It offers a wide voltage and current range precisely. ◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits) 2000mA ~ 20A 2 ranges+(0.3% rdg + 2 digits). ◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits). ◎Load: At full load. ◎Wires: The resistance of the wires must be small. 1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range (2:1 and 4:1)。 EX: Narrow input voltage range(±10%) 5V nominal input 4.5~5.5V 12V nominal input 10.8~13.2V 24V nominal input 21.6~26.4V Wide input voltage range 2:1 5V nominal input 12V nominal input 24V nominal input 48V nominal input 4.5~9V 9~18V 18~36V 36~75V Wide input voltage range 4:1 (W) 24V nominal input 9~36V 48V nominal input 18~75V 2. Input power : Pin = Vin x Iin Vin:Input voltage Iin:Input current Pout = Vout x Iout Vout:Output voltage Iout:Output current 3. Output power : 4. Efficiency : Efficiency = Pout Pin x100% Pout: Output power Pin: Input power 5. Voltage accuracy: │Vout-Vout(nominal)│ │ Vout [email protected] x100% Vout:Output voltage Vout(nominal):Nominal output voltage www.bothhandusa.com Rev:20120814A Page 5 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA ││││ ││││ 6. Line regulation: (1) Wide input voltage range and regulated output voltage series. │Vout(LL)-Vout(HL)│ │ Vout(LL) LL: Low Line input voltage HL: High Line input voltage x100% (2) Narrow input voltage range(±10%)and unregulated output voltage series. Line regulation= Δ Vout Δ Vin ΔVout = Vout(+10%)-Vout(-10%) x100% Vout Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load Vout:Output voltage at Vin = Vin(nominal)&full load ΔVin = Vin(+10%)-Vin(-10%) x100% Vin(nominal) Vin(+10%):Input voltage = 1.1xVin(nominal) Vin(-10%):Input voltage = 0.9xVin(nominal) Vin(nominal):Nominal Input voltage 7. Load regulation : │ x100% │Vout(FL)-Vout(NL)│ Vout(FL) Vout(FL): Output voltage at full load Vout(NL): Output voltage at 25% full load or 10% full load 8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz. Ripple&Noise Noise Ripple [email protected] www.bothhandusa.com Rev:20120814A Page 6 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Bothhand USA Output Ripple&Noise measurement test circuit: as shown below. Copper strip DC/DC converter Co Oscilloscope Load Copper strip Co: usually 0.47uF. 9. Temperature derating curve: The DC-DC converter will operate over a wider temperature range if less power is Output Power (%) drawn from the output and the device is already running. The temperature derating curve shows the operating power-temperature range. As shown below. Ambient Temp.TA (℃) 10. Switching frequency: The nominal operating frequency of the DC-DC converters. 11. Input to output isolation: The dielectric breakdown strength test between input and output circuits. This is the isolation voltage the device is capable of withstanding for a specified time, usually 1 second or 1 minute. [email protected] www.bothhandusa.com Rev:20120814A Page 7 of 7