CHECKER LAMP FOR UVTRON

CHECKER LAMP FOR
UVTRON®
UV SOURCE L9657-03
The L9657-03 UV source is a UV lamp designed to check the
operation of UVTRON flame sensors which are widely used
for fire alarm and combustion monitoring devices.
Since the L9657-03 is very small and highly reliable in lighting
up, it can be assembled with a UVTRON into existing devices
to check UVTRON operation easily and accurately.
Checking UVTRON operation helps improve the reliability of
the devices that use UVTRON flame sensors.
SPECIFICATIONS
10 mm
GENERAL
Parameter
Spectral distribution
Window material
Weight
Description / Value
185 to 400
UV glass
Approx. 1
Unit
nm
—
g
Figure 1: Spectral distribution
Description / Value
600
200
Unit
V
µA
-20 to +60
°C
RECOMMENDED OPERATING CONDITIONS
AND CHARACTERISTICS (at 25 °C)
Parameter
Discharge starting voltage
(DC) (Max.)
Recommended
supply voltage (DC)
Recommended
discharge current
Guaranteed life 2
Description / Value
Unit
260
V
300
V
150
µA
1000
h
NOTES:
1Operating at a current higher than this value may drastically shorten
the operating life.
2Life end is defined as the time that the radiant intensity falls to 50 %
of its initial value.
100
RELATIVE IRRADIANCE (%)
Parameter
Supply voltage (DC)
Peak current 1
Operating/storage
temperature range
Data below 200 nm is for reference.
TPT B0047EA
MAXIMUM RATINGS
75
50
25
0
200
250
300
350
400
WAVELENGTH (nm)
Figure 2: Directivity (light distribution)
0°
●Measurement image
-30°
30°
ANODE
-60°
-90°
-100
CATHODE
60°
-80
-60
-40
-20
0
20
40
60
80
90°
100
RELATIVE IRRADIANCE (%)
CATHODE
ANODE
TPT B0048EA
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2016 Hamamatsu Photonics K.K.
CHECKER LAMP FOR UVTRON®
UV SOURCE L9657-03
Figure 3: Dimensional outlines (Unit: mm)
Figure 4: Recommended operating circuit
5.8 ± 0.7
1 MΩ*
ANODE
CATHODE
CATHODE
25 ± 3
Approx. 150 µA
DISCHARGE POINT
ANODE MARK (RED)
* This 1 MΩ resistor must be connected within 1 cm from the
end of the anode lead of the L9657-03 UV source.
7±1 5±2
14 ± 2
LEAD
0.7 ± 0.1
ANODE
UV SOURCE
L9657-03
DC 300 V
TPTC0031EA
2±1
4±2
8±2
SIDE VIEW
FRONT VIEW
TPT A0054EA
■HANDLING PRECAUTIONS
●Soldering
When mounting the L9657-03 on a printed circuit board, solder the leads as quickly as possible (350 °C within 5
seconds). If the leads are heated excessively, the glass bulb may crack and the performance characteristics may
deteriorate.
●Vibration and shock
The L9657-03 is designed to pass vibration and shock tests in compliance with IEC 60068-2-6 (sinusoidal vibration test:
1.5 mm peak to peak, 100 m/s2,10 Hz to 500 Hz) and IEC 60068-2-27 (shock test: 1000 m/s2, 11 ms). However, if
subjected to strong mechanical shocks such as drop impacts, the glass bulb might crack or the internal electrode
deform, causing poor electrical characteristics. So use extreme caution when handling.
●Polarity
The L9657-03 has an anode and cathode, so be sure to connect them with the correct polarity. Mistakenly reversing the
connection polarity may cause malfunction or breakdown.
●Use in the dark
Avoid using the L9657-03 in the dark at an illuminance of 50 lx or less.
If used in the dark, a delay of 0.5 seconds or more may occur between the ON signal and the start of operation.
●Use after long-term storage
The amount of ions inside the bulb decreases after a long period of storage and this may cause the discharge starting
voltage to increase and a delay in lighting up as in the case in the dark. So before using the L9657-03 after long-term
storage, make sure that it lights up properly.
■WARRANTY
The L9657-03 is covered by a warranty for a period of one year after delivery. The warranty is limited to replacement of
the defective product. Even if within one year after delivery, the warranty will not cover any defect when the operating time
has exceeded the guaranteed life. The warranty will also not cover any malfunction or trouble caused by improper use or
natural disaster.
* UVTRON is a registered trademark of Hamamatsu Photonics K. K.
HAMAMATSU PHOTONICS K.K.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: [email protected]
TPT 1032E01
China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]
Taiwan: Hamamatsu Photonics Taiwan Co., Ltd.: 8F-3, No.158, Section2, Gongdao 5th Road, East District, Hsinchu, 300, Taiwan R.O.C. Telephone: (886)03-659-0080, Fax: (886)07-811-7238 E-mail: [email protected]
MAR. 2016 IP