Mini-spectrometer TG series C11118GA Long-wavelength type (to 2.55 μm) nearinfrared mini-spectrometer Hamamatsu TG series mini-spectrometers are polychromators integrated with optical elements and an image sensor. Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the builtin image sensor is output from the USB port to a PC for data acquisition. The C11118GA has sensitivity extending to longer wavelengths (up to 2.55 μm) than the existing C9914GB (up to 2.2 μm). The C11118GA comes supplied with free evaluation software that allows setting measurement conditions, acquiring and saving data, and displaying graphs. Original measurement software can be designed on an end-user’s side as DLL’s function specification is disclosed. Features Applications Spectral response range: 0.9 to 2.55 μm Measurement of C-H group absorption (2.3 μm band) Compatible with USB 2.0 interface Soil analysis and component analysis High throughput due to transmission grating made of quartz Highly accurate optical characteristics Low noise: cooled type Compact design for easy assembly Wavelength conversion factor*1 is recorded in internal memory Compatible with external trigger *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor for converting the A/D converted count into the input light intensity is not provided. Optical characteristics (Ta=25 °C) Parameter Spectral response range Spectral resolution (spectral response half width)*2 Wavelength reproducibility*3 Wavelength temperature dependence Spectral stray light*2*4 Specification 0.9 to 2.55 20 max. -0.8 to +0.8 -0.08 to +0.08 -30 max. Unit μm nm nm nm/°C dB *2: Depends on the slit opening. Values were measured with the slit listed in the table " Structure". *3: Measured under constant light input conditions, etc. *4: When monochromatic light of λ=1700 nm is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured at a wavelength 40 nm longer or shorter than the input wavelength. Electrical characteristics (Ta=25 °C) Parameter A/D conversion Integration time*5 Interface USB bus power current consumption Current consumption for cooling element (+5 V)*7 Current consumption for cooling fan (+12 V)*7 Specification 16 6 to 40000*6 USB 2.0 250 max. 2.8 max. 0.2 max. Unit bits μs mA A A *5: Depends on the image sensor dark current. *6: Excluding defective pixels *7: Maximum value in steady state. Note that inrush current flows at start-up. www.hamamatsu.com 1 Mini-spectrometer TG series C11118GA Structure Parameter Dimensions (W × D × H) Specification 142 × 218 × 82 1.7 InGaAs linear image sensor (G9208-256W) 256 140 × 500 0.22 SMA905D -20 Weight Image sensor Number of pixels*8 Slit*9 (H × V) NA*10 Connector for optical fiber Image sensor cooling temperature Unit mm kg pixels μm °C *8: Up to 3 discontinuous defective pixels might exist (when inspecting at low gain). Defective pixels are those whose electrical and optical characteristics do not meet our specifications. *9: Entrance slit aperture size *10: Numerical aperture (solid angle) Absolute maximum ratings Parameter Operating temperature*11 Storage temperature*11 Value +5 to +35 (+5 to +30*12) -20 to +70 Unit °C °C *11: No dew condensation When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability. *12: Range capable of cooling control Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings. Linearity (typical example) (Ta=25 °C) 20 (Low gain) 100000 Typical example of A/D output Ideal value of A/D output Difference between ideal value and typical example 19 8 6 17 4 16 2 A/D output Spectral resolution (nm) 18 10 15 14 0 10000 -2 13 -4 12 -6 11 -8 10 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Wavelength (nm) 1000 1 10 -10 100 Difference between ideal value and typical example (% Spectral resolution vs. wavelength (typical example) Integration time (ms) KACCB0213EA KACCB0256EA A/D output is the output with dark output is subtracted when light is input. The difference between the ideal value and typical example contains a measurement error. The smaller the A/D output, the larger the measurement error. 2 Mini-spectrometer TG series C11118GA Dark output vs. ambient temperature (typical example) (Integration time 40 ms, Low gain) A/D output (averaged over all pixels) 70000 60000 50000 40000 30000 20000 10000 0 0 10 20 30 40 50 Ambient temperature (°C) KACCB0257EA A/D output is the sum of the sensor and circuit offset outputs and the sensor dark output. Optical component layout TG series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics. Focus lens Transmission grating Image sensor Collimating lens Input slit KACCC0256EA 3 Mini-spectrometer TG series C11118GA Connection example (transmission light measurement) Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the builtin image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup. PC USB cable Fiber light source Mini-spectrometer C11118GA Power supply for cooling element and cooling fan * Quartz cell (for holding liquid sample) FIBER * External power supply should be prepared by the user. KACCC0490EA Evaluation software (supplied with unit) Installing the evaluation software (SpecEvaluationUSB2.exe)*13 into your PC allows running the following basic tasks: · Measurement data acquisition and save · Measurement condition setup · Module information acquisition (wavelength conversion factor, polychromator type, etc.) · Graphic display · Arithmetic function Pixel number to wavelength conversion Comparison calculation with reference data (transmittance, reflectance) Dark subtraction Gaussian approximation (peak position and count, FWHM) Note: Up to 8 mini-spectrometers can be connected and used with one PC. *13: Compatible OS: Microsoft® Windows® 7 Professional SP1 (32-bit, 64-bit) Microsoft® Windows® 8 Professional (32-bit, 64-bit) DLL for controlling hardware is also provided. You can develop your own measurement programs by using a following software development environment. Microsoft® Visual Studio® 2008 (SP1) Visual C++® Microsoft® Visual Studio® 2008 (SP1) Visual Basic® Note: Microsoft, Windows, Visual Studio, Visual C++ and Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries. 4 Mini-spectrometer TG series C11118GA Dimensional outline (unit: mm) 218 142 COOLED NIR-III (λ: 2.55) Spectrometer 82 ± 2 COOLED NIR-III (λ: 2.55) Spectrometer Tolerance unless otherwise noted: ±1.0 Weight: 1.7 kg KACCA0258ED Accessories · USB cable · Dedicated software (evaluation software, DLL) · Power supply connector for cooling element and cooling fan (FGG0B304CLAD56 made by LEMO S.A.) Options (sold separately) · Optical fiber for light input Type no. Product name Core diameter (μm) A9763-01 Fiber for visible/near infared range 600 Specification NA=0.22, length 1.5 m, connectorized SMA905D at both ends · Coaxial cable for external trigger input A10670 ϕ14.5 Dimensional outline (unit: mm) ϕ6.4 Cable length: 1.5 m Cable specification: 1.5QEV 26.0 LEMO connector FFA.00.250 (made by LEMO) 31.7 BNC connector BNC-P-1.5 (40) (made by HIROSE or equivalent) KACCA0220EB 5 Mini-spectrometer TG series C11118GA Mini-spectrometer lineup Type no. Type C10082CAH TM-UV/VIS-CCD High resolution C10082MD C10083CA C10083CAH Mini-spectrometer TM series C10082CA TM-UV/VIS-CCD High sensitivity TM-VIS/NIR-MOS-II Trigger-compatible Mini-spectrometer TG series TG-UV-CCD High resolution C11482GA Non-cooled type C13053MA C13054MA C13555MA C11007MA C11008MA Back-thinned CCD image sensor CMOS linear image sensor 3 200 to 400 1* 500 to 1100 500 to 600 790 to 920 Back-thinned CCD image sensor 5 (λ=550 to 900 nm) IR-enhanced back-thinned CCD image sensor 0.3* Back-thinned CCD image sensor 0.3* IR-enhanced back-thinned CCD image sensor Mini-spectrometer TG series TG2-NIR Mini-spectrometer Mini-spectrometer RC series TF series C11118GA Image sensor 8 (λ=320 to 900 nm) Back-thinned CCD image sensor 1* (λ=320 to 900 nm) CMOS linear 8 image sensor High-sensitivity CMOS 8 linear image sensor 320 to 1000 TG-RAMAN-I High resolution TG-RAMAN-II High resolution C9914GB 1* 6 TG-SWNIR-CCD-II IR-enhanced C11714CB C9913GC 200 to 800 TG-UV-CCD High sensitivity C9404CA Spectral resolution max. (nm) 6 TM-VIS/NIR-CCD High resolution C11697MB C11713CA Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 600 TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-MOS Wide dynamic range C9405CB 400 TM-UV/VIS-MOS Wide dynamic range C10083MD C9404CAH 200 7 900 to 1700 TG-cooled NIR-I Low noise (cooled type) 7 TG-cooled NIR-II Low noise (cooled type) 1100 to 2200 TG-cooled NIR-III Low noise (cooled type) 900 to 2550 TF-SWIR-MOS-II 500 to 1100 Compact, thin case TF-RAMAN 790 to 920 Compact, thin case TF-VIS-MOS-II 340 to 830 Compact, thin case RC-VIS-MOS 340 to 780 Spectrometer module RC-SWNIR-MOS 640 to 1050 Spectrometer module 8 InGaAs linear image sensor 20 3.5 0.4* High-sensitivity CMOS linear image sensor 3 9 CMOS linear image sensor 8 IR-enhanced CMOS linear image sensor Spectral resolution max. (nm) Image sensor 9 CMOS linear image sensor 8 IR-enhanced CMOS linear image sensor Spectral resolution max. (nm) Image sensor 20 CMOS linear image sensor 15 CMOS linear image sensor 15 High-sensitivity CMOS linear image sensor * Typ. For installation into mobile measuring equipment C11009MA C11010MA Type Mini-spectrometer RC series Type no. 200 RC-VIS-MOS 400 Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 600 340 to 780 Spectrometer head RC-SWNIR-MOS 640 to 1050 Spectrometer head For installation into mobile measuring equipment (ultra-compact) C11708MA C12666MA C12880MA Type MicroMini-spectrometer spectrometer MS series Type no. MS-SWNIR-MOS Spectrometer head Spectrometer head Spectrometer head 200 400 600 Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 640 to 1050 340 to 780 340 to 850 6 Mini-spectrometer TG series C11118GA Related information http://www.hamamatsu.com/sp/ssd/doc_en.html Precautions ∙ Disclaimer ∙ Mini-spectrometers Technical information ∙ Mini-spectrometers Information described in this material is current as of February, 2016. Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always contact us for the delivery specification sheet to check the latest specifications. The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product use. Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741 China: Hamamatsu Photonics (China) Co., Ltd.: B1201, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866 Cat. No. KACC1170E12 Feb. 2016 DN 7