c11713ca c11714cb kacc1225e

Mini-spectrometers
TG series
C11713CA
C11714CB
For Raman spectrophotometry,
high resolution type (spectral resolution: 0.3 nm)
The C11713CA and C11714CB are polychromators integrated with optical elements, an image sensor and a driver circuit. Light
to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the
built-in image sensor is output from the USB port to a PC for data acquisition. The C11713CA has sensitivity in a wavelength
range of 500 to 600 nm, while the C11714CB covers a range of 790 to 920 nm. Both types offer a spectral resolution of 0.3
nm. Their products come supplied with free evaluation software that allows setting measurement conditions, acquiring and
saving data, and displaying graphs. Original measurement software can be designed on an end-user’s side as DLL’s function
specification is disclosed.
Features
Applications
High accuracy optical characteristics:
spectral resolution 0.3 nm
Raman spectrophotometry
Easy to install into equipment due to compact design
High throughput due to transmission grating made of quartz
Wavelength conversion factor is recorded in internal memory *1
*1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor
for converting the A/D converted count into the input light intensity is not provided.
Selection guide (Typ.)
Parameter
Spectral response range
Spectral resolutiion
Built-in image sensor
C11713CA
500 to 600
C11714CB
790 to 920
Unit
nm
nm
0.3
IR-enhanced
back-thinned CCD image sensor
Back-thinned CCD image sensor
-
High sensitivity in near infrared region (C11714CB)
Spectral response
Using a CCD image sensor with enhanced near infrared
sensitivity, the C11714CB offers higher sensitivity than that of
the previous product.
(Typ. Ta=25 °C)
100
90
Relative photosensitivity (%)
C11714CB
80
70
Previous product
60
50
40
30
20
10
0
750
800
850
900
950
Wavelength (nm)
KACCB0371EA
www.hamamatsu.com
1
TG series
Mini-spectrometers
C11713CA, C11714CB
Structure
Parameter
Dimensions (W × D × H)
Weight
Image sensor
Number of pixels
Slit*2 (H × V)
NA*3
Connector for optical fiber
A/D conversion
Interface
External power supply (AC adapter)
C11713CA
C11714CB
120 × 70 × 60
592
Back-thinned type CCD image sensor IR-enhanced back-thinned CCD image sensor
(S10420-1106-01)
(S11510-1006)
2048
1024
10 × 1000
0.11
SMA905D
16
USB 1.1
AC 100V-240V, 50/60Hz
Unit
mm
g
pixels
μm
bit
°C
*2: Entrance slit aperture size
*3: Numeric aperture (solid angle)
Absolute maximum ratings
Parameter
External power supply voltage
Operating temperature*4
Storage temperature*4
Value
5.25
+5 to +40
-20 to +70
Unit
V
°C
°C
*4: No dew condensation
When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation
may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability.
Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the
product within the absolute maximum ratings.
Electrical characteristics (Ta=25 °C, unless otherwise noted)
Parameter
Integration time
Consumption current of USB bus power*5
External power supply voltage
Consumption current of external power supply*5
Min.
-
Typ.
10 to 10000
5
-
Max.
Unit
ms
mA
V
A
150
0.8
*5: When operated with the supplied evaluation software (at default settings, dark state, excluding start-up).
Electrical and optical characteristics (Ta=25 °C, unless otherwise noted)
Parameter
Spectral response range
Spectral resolution (FWHM)*6
Wavelength reproducibility*7
Wavelength temperature dependence
Spectral stray light*6 *8
Min.
-
-
C11713CA
Typ.
500 to 600
0.3
-0.1 to +0.1
-0.04 to +0.04
-
Max.
Min.
0.5
-
-30
-
C11714CB
Typ.
790 to 920
0.3
-0.1 to +0.1
-0.04 to +0.04
-
Max.
0.5
-30
Unit
nm
nm
nm
nm/°C
dB
*6: Depends on the slit opening. Values were measured with the slit listed in the table “ Structure”.
*7: Measured under constant light input conditions
*8: When monochromatic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count measured at
the input wavelength, to the count measured in a region of the input wavelength ±10 nm
C11713CA: 550 nm, C11714CB: 860 nm
2
TG series
Mini-spectrometers
C11713CA, C11714CB
Spectral response (typical example)
C11713CA
C11714CB
(Typ. Ta=25 °C)
90
90
80
80
70
60
50
40
30
70
60
50
40
30
20
20
10
10
0
450
500
550
600
(Typ. Ta=25 °C)
100
Relative sensitivity (%)
Relative sensitivity (%)
100
0
750
650
800
850
900
950
Wavelength (nm)
Wavelength (nm)
KACCB0240EA
KACCB0372EA
Spectral resolution vs. wavelength
C11713CA
C11714CB
(Typ. Ta=25 °C)
0.5
0.4
Spectral resolution (nm)
Spectral resolution (nm)
0.4
0.3
0.2
0.1
0
450
(Typ. Ta=25 °C)
0.5
0.3
0.2
0.1
500
550
600
650
0
750
800
850
900
950
Wavelength (nm)
Wavelength (nm)
KACCB0224EA
KACCB0373EA
3
TG series
Mini-spectrometers
C11713CA, C11714CB
Linearity (typical example)
Typical example of A/D output
Ideal value of A/D output
Difference between ideal value
and typical example
8
6
10000
4
A/D output
2
1000
0
-2
-4
100
-6
-8
10
10
100
-10
10000
1000
100000
10
Typical example of A/D output
Ideal value of A/D output
Difference between ideal value
and typical example
8
6
10000
4
A/D output
10
100000
Difference between ideal value and typical example (%)
C11714CB
Difference between ideal value and typical example (%)
C11713CA
2
1000
0
-2
-4
100
-6
-8
10
10
100
-10
10000
1000
Integration time (ms)
Integration time (ms)
KACCB0235EA
KACCB0374EA
A/D output is the output with dark output is subtracted when light is input. The difference between the ideal value and
typical example contains a measurement error. The smaller the A/D output, the larger the measurement error.
Dark output vs. ambient temperature (typical example)
C11713CA
(Integration time 1 s)
60000
50000
40000
30000
20000
10000
0
(Integration time 1 s)
70000
A/D output (averaged over all pixels)
70000
A/D output (averaged over all pixels)
C11714CB
60000
50000
40000
30000
20000
10000
0
0
10
20
30
40
50
0
10
20
30
40
50
Ambient temperature (°C)
Ambient temperature (°C)
KACCB0237EA
KACCB0375EA
A/D output is the sum of the sensor and circuit offset outputs and the sensor dark output.
4
Mini-spectrometers
TG series
C11713CA, C11714CB
Connection example (transmission light measurement)
Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the
built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable
measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement
setup.
AC adapter
Minispectrometer
PC
USB cable
Exciting LD light source
Fiber
Raman probe
Measuring cell
KACCC0577EB
Optical component layout
TG series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a
rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics.
Focus lens
Transmission grating
Image sensor
Collimating lens
Input slit
KACCC0256EA
5
TG series
Mini-spectrometers
C11713CA, C11714CB
Measurement example
Raman spectrophotometry using nophthalene (C11714CB)
14000
(Pump laser 785 nm/60 mW, connection fiber 200 μm core dia., integration time 5 s)
12000
A/D counts
10000
8000
6000
4000
2000
0
790 800
820
840
860
880
900
920
Wavelength (nm)
KACCB0229EA
Evaluation software package (supplied with unit)
Installing the evaluation software package (Spec Evaluation.exe)*8
into your PC allows running the following basic tasks:
· Measurement data acquisition and save
· Measurement condition setup
· Module information acquisition
(wavelength conversion factor, polychromator type, etc.)
· Graphic display
· Arithmetic operation
Pixel number to wavelength conversion
Comparison calculation with reference data
(transmittance, reflectance)
Dark subtraction
Gaussian approximation
(peak position and count, FWHM)
Note:
· Two or more mini-spectrometers can be connected and used
with one PC simultaneously.
· The external trigger input function does not work with the evaluation software. If using an external trigger input or designing original
application software, the user software must be configured to support that function.
*8: Compatible OS: Microsoft® Windows® 7 Professional SP1 (32-bit, 64-bit)
Microsoft® Windows® 8 Professional (32-bit, 64-bit)
DLL for controlling hardware is also provided.
You can develop your own measurement programs by using a following software development environment.
Microsoft® Visual Studio® 2008 (SP1) Visual C++®
Microsoft® Visual Studio® 2008 (SP1) Visual Basic®
Note: Microsoft, Windows, Visual Studio, Visual C++ and Visual Basic are either registerd trademarks or trademarks of Microsoft
Corporation in the United States and other countries.
6
TG series
Mini-spectrometers
C11713CA, C11714CB
Dimensional outline (unit: mm, tolerance unless otherwise noted: ±0.5)
120.0
50.0 ± 0.2
60.0
70.0
(4 ×) M3.0 tap depth 5
(from backside)
110.0 ± 0.2
Weight: 592 g
KACCA0281EB
Accessories
· USB cable
· Dedicated software (evaluation software, sample software, DLL)
· AC adapter (for power supply)
Options (sold separately)
· Coaxial cable for external trigger input A10670
· Optical fibers for light input
Type no.
Product name
Fiber for visible/near
infrared range
A9763-01
Core diameter (μm)
Specification
600
NA=0.22, length 1.5 m,
connectorized SMA905D
at both ends
ϕ14.5
Dimensional outline (A10670, unit: mm)
ϕ6.4
Cable length: 1.5 m
Cable specification: 1.5QEV
26.0
LEMO connector
FFA.00.250 (made by LEMO)
31.7
BNC connector
BNC-P-1.5 (40) (made by HIROSE or equivalent)
KACCA0220EB
7
TG series
Mini-spectrometers
C11713CA, C11714CB
Mini-spectrometer/micro-spectrometer lineup
Type no.
Type
TM-UV/VIS-CCD
High sensitivity
C10082CAH
TM-UV/VIS-CCD
High resolution
C10082MD
C10083CA
C10083CAH
Mini-spectrometer
TM series
C10082CA
TM-VIS/NIR-MOS-II
Trigger-compatible
Mini-spectrometer
TG series
TG-UV-CCD
High resolution
C11482GA
Non-cooled type
C13053MA
C13054MA
C13555MA
C11007MA
C11008MA
Back-thinned CCD
image sensor
CMOS linear
image sensor
3
200 to 400
1*
500 to 1100
500 to 600
790 to 920
Back-thinned CCD
image sensor
5
(λ=550 to 900 nm)
IR-enhanced
back-thinned CCD
image sensor
0.3*
Back-thinned CCD
image sensor
0.3*
IR-enhanced
back-thinned CCD
image sensor
Mini-spectrometer
TG series
TG2-NIR
Mini-spectrometer Mini-spectrometer
RC series
TF series
C11118GA
Image sensor
8
(λ=320 to 900 nm) Back-thinned CCD
image sensor
1*
(λ=320 to 900 nm)
CMOS linear
8
image sensor
High-sensitivity CMOS
8
linear image sensor
320 to 1000
TG-RAMAN-I
High resolution
TG-RAMAN-II
High resolution
C9914GB
1*
6
TG-SWNIR-CCD-II
IR-enhanced
C11714CB
C9913GC
200 to 800
TG-UV-CCD
High sensitivity
C9404CA
Spectral resolution
max.
(nm)
6
TM-VIS/NIR-CCD
High resolution
C11697MB
C11713CA
Spectral response range (nm)
800 1000 1200 1400 1600 1800 2000 2200 2400 2600
600
TM-VIS/NIR-CCD
High sensitivity
TM-VIS/NIR-MOS
Wide dynamic range
C9405CB
400
TM-UV/VIS-MOS
Wide dynamic range
C10083MD
C9404CAH
200
7
900 to 1700
TG-cooled NIR-I
Low noise (cooled type)
7
TG-cooled NIR-II
Low noise (cooled type)
1100 to 2200
TG-cooled NIR-III
Low noise (cooled type)
900 to 2550
TF-SWIR-MOS-II
500 to 1100
Compact, thin case
TF-RAMAN
790 to 920
Compact, thin case
TF-VIS-MOS-II
340 to 830
Compact, thin case
RC-VIS-MOS
340 to 780
Spectrometer module
RC-SWNIR-MOS
640 to 1050
Spectrometer module
8
InGaAs linear
image sensor
20
3.5
0.4*
High-sensitivity
CMOS linear
image sensor
3
9
CMOS linear
image sensor
8
IR-enhanced
CMOS linear
image sensor
Spectral resolution
max.
(nm)
Image sensor
9
CMOS linear
image sensor
8
IR-enhanced
CMOS linear
image sensor
Spectral resolution
max.
(nm)
Image sensor
20
CMOS linear
image sensor
15
CMOS linear
image sensor
* Typ.
For installation into mobile measuring equipment
C11009MA
C11010MA
Type
Mini-spectrometer
RC series
Type no.
200
RC-VIS-MOS
400
Spectral response range (nm)
800 1000 1200 1400 1600 1800 2000 2200 2400 2600
600
340 to 780
Spectrometer head
RC-SWNIR-MOS
640 to 1050
Spectrometer head
For installation into mobile measuring equipment (ultra-compact)
C11708MA
C12666MA
Type
Mini-spectrometer
rometer MS series
Type no.
MS-SWNIR-MOS
Spectrometer head
Spectrometer head
200
400
600
Spectral response range (nm)
800 1000 1200 1400 1600 1800 2000 2200 2400 2600
640 to 1050
340 to 780
i h
i i i
8
Mini-spectrometers
TG series
C11713CA, C11714CB
Related information
www.hamamatsu.com/sp/ssd/doc_en.html
Precautions
· Disclamer
· Mini-spectrometers
Technical information
· Mini-spectrometers
Information described in this material is current as of October, 2015.
Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the
information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always
contact us for the delivery specification sheet to check the latest specifications.
The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that
one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product use.
Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741
China: Hamamatsu Photonics (China) Co., Ltd.: B1201, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866
Cat. No. KACC1225E02 Oct. 2015 DN