7850 E. Gelding Drive Scottsdale, AZ 85260 USA 1-877-2BUYNKK (228-9655) Phone 480.991.0942 Fax 480.998.1435 www.nkksmartswitch.com 06–07 Demonstration Kit User Guide CONTENTS NOTES Introduction . . . . . . . . . . . . . . . . . . . 2 Shipping Contents . . . . . . . . . . . . . . 3 Hardware Installation . . . . . . . . . . . . 4 Software Installation . . . . . . . . . . . . . 5 Programming Bitmaps . . . . . . . . . . . . 7 Demonstration Kit Specifications . . . . . 8 Battery Box Specifications . . . . . . . . 13 Precautions for Handling & Storage . .14 INTRODUCTION This User Guide will assist you in using the IS Demonstration Kit (DEM KIT), consisting of an IS switch or IS display module mounted on PC board. A subminiature controller manages 64 bitmaps and backlight data. Bitmap data is controlled by 6-bit parallel TTL level signal and is edited by the “IS Easy Editor,” downloaded to the kit via USB Type A-mini B cable (required for connection to a PC). “IS Easy Editor” is the software to create and edit graphics. A variety of tool functions allows you to customize bitmap images as well as change the setting of the backlight. Transfer of graphic data is simple with IS Easy Display Controller. An assortment of samples is available, allowing customization of graphic images with ease for your applications. 2 15 PRECAUTIONS FOR HANDLING & STORAGE Handling 1. The IS Series devices are electrostatic sensitive. ATTENTION ELECTROSTATIC SENSITIVE DEVICES SHIPPING CONTENTS 1. Demonstration Kit User Guide 2. CD for “IS Easy Editor” Software and Manual 2. Avoid excessive force to protect the LCD. 3. SMARTDISPLAYTM Mounted on Controller Board 3. Do not exceed 60°C at the LCD level. 4. If the LCD is accidentally broken, avoid contact with the liquid and wash off any liquid spills to the skin or clothing. 4. SMARTSWITCHTM Mounted on Controller Board 5. Do not connect to PC via USB when IS Easy Disply Kit is mounted on battery box. 6. Deviation of drive current and temperature may change LCD contrast. Control contrast via contrast adjustment on backside of IS Controller. or 5. Connector Block 6. USB Type A-Mini B Cable 7. (Optional) Battery Box (Batteries not included) 7. The IS series devices are not process sealed. 8. Clean cap surface with dry cloth. If further cleaning is needed, wipe with dampened cloth using neutral cleanser and dry with clean cloth. Do not use organic solvent. 7 1 Storage 1. Store away from direct sunlight. 2. Keep away from static electricity. 3. Avoid extreme temperatures, high humidity, gaseous substances, and all forms of chemical contamination. 6 2 5 4 14 or 3 3 (OPTIONAL) BATTERY BOX SPECIFICATIONS HARDWARE INSTALLATION The Connector Block (A) is required to illuminate the backlight of the DEM KIT while programming through the USB Type A-mini B cable. Pin 1 Connect as shown, prior to connecting to the USB cable. Note the orientation of the Connector Block to that of the DEM KIT. Connector Block (A) The Connector Block is used ONLY during the programming phase; it is not used with the Battery Box option. The Battery Box provides portability to demonstrate functionality without any system connections. • Power Switch activates power • FWD/REV Switch directs sequences of bitmaps for IS15 SMARTSWITCH TM • Knob for cycling bitmaps may also simulate animation • Socket to mount IS Easy Display Controller • Battery holder accommodates four (4) AA alkaline batteries (not included) Note: Orientation of DEM KIT–1 or DEM KIT–2 to Battery Box (100.0) 3.937 (70.0) 2.756 Power Switch (35.0) 1.378 Knob to cycle through bimaps for both IS15 and IS01 Switch to direct the sequence of bitmaps for IS15 SMARTSWITCH TM Connector for IS Easy Display Kit 4 13 IMPORTANT! READ BEFORE SOFTWARE INSTALLATION TYPICAL DEM KIT DIMENSIONS Dem Kit –1 Side View Dem Kit –2 Side View 1. Read installation manual on CD (See Figure A). 2. Do not connect hardware (IS Easy Display Controller) until installation of drivers. 3. Turn off all resident software (i.e., antivirus software) before beginning installation. 4. Make sure you have administrative rights to install software on your computer. 5. Minimum system requirements: (2.54) .100 (2.54) .100 (1.6) .063 (10.1) .398 (26.9) 1.059 CN1 USB Mini-B Connector (17.4) .685 (1.6) .063 (10.1) .398 (2.8) DiaTyp .110 (3.0) .118 • CPU Pentium or compatible processor • OS Windows XP Professional, Windows XP Home Edition Windows 2000 Professional (Service Pack 2 or later) Windows 98 Second Edition • RAM 128MB • Disk Space 60MB of available space • Browser Internet Explorer 6.0 or later SOFTWARE INSTALLATION (20.5) .807 (16.5) .650 (21.0) .827 Application Top View 12 (16.0) .630 (24.5) .965 2 16 15 (20.0) .787 1 (44.5) 1.752 (7.0) .276 Contrast Adjustment Bottom View CN2 2.54mm 16-pin Header Connector 1. Click on “Installation of ‘IS Easy Editor’ Application” (see Figure A). “End User License Agreement” window appears. Click “Agree” to continue. 2. Follow the onscreen instructions to load your software and configure the settings. Figure A 3. “Install Complete” window appears. Click “Finish”. 5 SOFTWARE INSTALLATION (CONTINUED) Control of Backlight LEDs 4. Installation window opens again (Figure A). Continue to install drivers. For LED control, settings of “IS Easy Editor” are transferred to IS Display Controller via switching transistors connected to LED_1c/LED_2c. 5. Click on “Installation of Drivers” and follow the onscreen instruc- tions. After installing drivers, follow directions as shown in Figure B. NOTE: CONTROLLING INFORMATION (CONTINUED) • To activate LED backlight, supply power to LEDs and insert resistor for current limitation. • Drive backlight LEDs at voltage two (2) times greater than forward voltage of LEDs. If using Windows XP, a warning message “has not passed Windows Logo testing” may appear. Click “Continue Anyway” in message box. Figure B DEM KIT–1 USB Type A Mini-B Cable allows transfer of bitmaps from PC to IS Easy Controller • Between LED_1k-LED_1c or LED_2k-LED_2c, insert resistors for current limitation as displayed in diagram below. LED_com 2 Resistor for Current Limit 7 LED_1k 8 LED_2k LED_1c 9 Backlight LED 10 LED_2c 3, 4 GND LED Control Output DEM KIT–2 Uninstall 1. To uninstall “IS Easy Editor”, locate “Add or Remove Programs” in Start/Control Panel. 2. Select “IS Easy Editor” and click “Change/Remove”. 6 NOTE: Consult factory if using IS Switch or Display other than what is included in DEM KIT. 11 PROGRAMMING BITMAPS BLOCK DIAGRAM Functions of IS Easy Display Controller • • CN1 Connector (USB Mini-B Connector) Transfers bitmaps created on PC to IS Easy Controller via USB Type A Mini-B Cable USB Mini-B E2 PROM CPU CN1 6 bit 6 LED Dr 2 16-pin Header Connector CN2 IS Series IS-15 IS-01 FLM/LP/SCP/Data 4 2 LED 3 SW 2 5 3.3V to 5V CN2 Connector 5V to 7~8V (2.54mm pitch 16-pin header) Connector for power supply, GND, switch operation, backlight LED control and selection of bitmaps CONTROLLING INFORMATION Control of Data Bitmap data is transferred to IS Easy Display Controller by setting the 6-bits parallel TTL level signals (terminals 11~16). To display desired bitmaps in “IS Easy Editor”, refer to diagram below and set appropriate values to terminals. 10 Connector CN2 Terminal Number/Logic Level Note: Bitmap image for reference only. Values Bitmap Number 16 15 14 13 12 11 1 L L L L L L 2 L L L L L H 3 L L L L H L • • • • • • • • • • • • • • • • • • • • • 62 H H H H L H 63 H H H H H L 64 H H H H H H Run “IS Easy Editor” and open “sample.isl” for test. File contains samples of created bitmaps. Low (L) Level = 0 ~ 0.8V High (H) Level = 2 ~ 5.25V Read and print “Graphic Editing Software Operating Manual” from the computer. See instructions below. 1. Go to “Start” on Windows screen 2. Select “Programs” 3. Find “IS Easy Editor” 4. Select Manual 7 PIN CONFIGURATIONS DEMONSTRATION KIT SPECIFICATIONS ATTENTION SMARTSWITCH TM ATTENTION ELECTROSTATIC SENSITIVE DEVICES ELECTROSTATIC SENSITIVE DEVICES SMARTDISPLAY TM Standard LED Backlighting Super Bright LED Backlighting Part Number LCD Mode LED Color Part Number LCD Mode LED Color IS15AACP4CF Yellow STN Positive Red/Green IS01BCCF Yellow STN Positive Red/Green Typical Electrical Characteristics (Temperature at 25°C) Backlight Color Symbols Red/Green Unit Forward Current IF 15/15 mA Forward Voltage VF 2.1/2.2 V Ratings (Temperature at 25°C) Items Symbols Ratings Supply Voltage for Logics VDD 5.0V ±10% Input Voltage VI 0 ~ 5.25V 0 ~ 28V Current I DD ~ 150mA Operating Temperature Range TOP 0 ~ 40°C Storage Temperature Range TST 0 ~ 60°C Description Supplied by USB while connected to PC Header connector pins 11 ~ 16 Header connector pin 2 Pin No. Symbol NameFunction 1 VDD Power 2 LED_com LED common (anode) 3 4 VSS Ground 5 SW 1 Switch 1 6 SW 2 Switch 2 7 LED_1k LED 1 (cathode) 8 LED_2k LED 2 (cathode) 9 LED_1c LED 1 Control (Open Collector) 10 LED_2c LED 2 Control (Open Collector) 11 Disp_1 Bitmap number set bit1 LSB bit 12 Disp_2 Bitmap number set bit2 13 Disp_3 Bitmap number set bit3 14 Disp_4 Bitmap number set bit4 15 Disp_5 Bitmap number set bit5 16 Disp_6 Bitmap number set bit6 MSB bit Supply +5.0V (When connected to PC via USB, do not supply the controller with another external power.) Common anode of backlight LEDs of IS External power supply terminal for drive of LEDs GND terminal IS15: Connected to switch terminal 1; IS01: no connection IS15: Connected to switch terminal 2; IS01: no connection Cathode terminal of backlight LED 1 Cathode terminal of backlight LED 2 Output terminal for backlight control set by “IS Easy Editor” * Connected to LED_1k terminal via resistor for current limitation Output terminal for backlight control set by “IS Easy Editor” * Connected to LED_2k terminal via resistor for current limitation } 0; Low (L) Level = 0 ~ 0.8V 1; High (H) Level = 2 ~ 5.25V * See Control of Data on next page 8 9