spf5103 ds en

500V breakdown voltage Full bridge driver C
■Features
SPF5103 (Negative drive system)
■Package
●500V breakdown voltage negative power supply drive system
Exclude gate remain dimension
●Encapsulate IGBT (4pieces) and a control MIC
●Compact type power surface mount package
Exclude flash
Include flash
●Suitable for inverter element for HID ballast unit
Gate
burr
■Absolute maximum ratings
No.
Item
Symbol
1
Power Source Voltage
2
Input Voltage
Unit
Rating
Conditions
between Power GND and –HV
VM
V
500
VIN
V
15
Ta=-40℃∼150℃
Ta=-40℃∼150℃
Vcc
V
15
Ta=-40℃∼150℃
VOUT
V
500
Ta=-40℃∼150℃
Output Current (DC)
IOUT(DC)
A
7
Ta=25℃
6
Output current (pulse)
IOUT(pulse)
A
22
Ta=125℃, Pulse width = 15μs
7
Total Power Dissipation
PD
W
27.2
Tc=25℃
8
Thermal Resistance
θj-c
℃/W
4.6
Tc=25℃
9
Operation Temperature
Topr
℃
-40∼+105
10
Storage Temperature
Tstg
℃
-40∼+150
11
Junction Temperature
Tj
℃
150
3
Operating Voltage
4
Output Voltage
5
■Circuit block diagram
Metal fin
Vcc UVLO
circuit
Filter circuit
Circuit
avoiding
same time
ON
Drive circuit
(for H/S Q1)
Drive circuit
(for L/S Q’1)
■Electrical characteristics
No.
1
2
3
Item
Symbol
Unit
Value
Min.
Typ.
Max.
570
IGBT Output
Breakdown Voltage
IGBT Output
Leakage Current
IGBT Output On-State Voltage
BVOUT
V
IOUT(off)
μA
VOUT(on)
Icc1
100
300※
VOUT=500V, Ta=-40∼150℃
500※
1.2
1.3
1.8
IOUT=2.0A, VIN=10V
3.0
Vcc=10V, VM=VIN=0V, Ta=25℃
V
mA
Quiescent Circuit Current
4.0
Icc2
mA
7.0
4.0
5
Operating Circuit Current
Icc3
mA
VIH
V
VIL
V
7.0
6
7
Delay time
Low side
0.2・Vcc
td(on)
2.0
2.3
td(off)
td(on)
2.4
1.0
2.8
1.4
μs
td(off)
1.6
⊿td
8
9
10
UVLO Voltage
UVLO start voltage
Hysteresis width
Operating Voltage
Vcc=9∼15V, VM=VIN=0V,
Ta=-40∼125℃
Vcc=10V, VM=450V, VIN=0V,
Ta=25℃
Vcc=9∼15V, VM=450V, VIN=0V
Ta=-40∼125℃
Vcc=10V, VM=450V
VIN1(orVIN2)=10V, Ta=25℃
Vcc=10V, VM=450V
VIN1(orVIN2)=10V
Ta=-40∼125℃
0.8・Vcc
Input Threshold Voltage
High side
2.1
3.0
Vcc=9∼15V
VM=85V, IO=0.41A
VCC=10V
VIN=10V(Out Stage=ON)
VIN=0V(Out Stage=OFF)
⊿td=H/S td(off) – L/S td(on)
or L/S td(off) – H/S td(on)
VUVLO+
V
5.7
6.2
6.7
VUVLO−
V
5.3
5.9
6.6
ΔVUVLO
V
0.1
0.2
0.4
ΔVUVLO = VUVLO+−VUVLO−
VCC
V
9
15
Ta=-40∼+105℃
Recommended operation
No.
Item
Symbol
1
Stable operation
2
Recommended dead time
dV/dt
■Typical connection diagram
IOUT=0.4A, VIN=10V
1.0
4.5
4
Conditions
IOUT=100μA, Ta=25℃
IOUT=100μA,
Ta=-40∼150℃
VOUT=500V, Ta=25℃
Unit
dV/dt
V/μs
td
μs
Value
Min.
Typ.
Max.
30
3
Conditions
Ta=−40∼150℃
Vcc=9∼15V, VM=400V
Ta=−40∼150℃
■Timing chart
Drive circuit
(for H/S Q2)
Drive circuit
(for L/S Q’2)