Operation Manual

Operational Manual: AS8510-DK
AS8510 Demo Board
www.ams.com
Revision x.x / xx/xx/xx
page 1/4
Operational Manual: AS8510-DK
Table of Contents
1
General Description ............................................................................................................. 3
2
Kit Content ........................................................................................................................... 3
3
Getting Started ..................................................................................................................... 3
4
Software Description ............................................................................................................ 3
5
Board Schematics, Layout and BOM ................................................................................... 3
6
Advanced Usage .................................................................................................................. 4
7
Ordering Information ............................................................................................................ 4
Revision History
Revision
Date
Owner
Description
1.0
20.05.2014
GHE
Operational Manual: AS8510-DK
www.ams.com
Revision 1 / 20/05/2014
page 2/4
Operational Manual: AS8510-DK
1
General Description
The AS8510 DemoKit for AS8510 Data Acquisition Front-End IC allows easy evaluation of the
AS8510 Features. Its USB connector allows easy access to all the chips features via a user friendly
Graphical PC Interface. The GUI is supplied with the Evaluation Board and can be used to plot
measured data as well as to access all the device registers and evaluate special settings.
2
Kit Content
Board + Cable, Software is available as download
3
Getting Started









4
Plug in the demo board via the provided USB cable
Windows will detect a new device and ask for a driver. It is in the driver folder of the
software package you got with the demo board.
After installing the driver you have to install the .net framework dotnet4_installer.exe
which is also in the software package.
After successful installation you have to find out the com port which the board was
assigned. Press WIN + Pause to open the system properties. Go to Hardware, Device
manager and Ports (COM&LPT) check for an entry called USB serial port and the
COM number besides it.
Open the Demo software under software\as8510demo.exe
Select the COM port you just figured out and click the green connect button.
A connect message will show in the title. You can now use the demo board as you like
Software Description
 SW AS8510 demo kit
 Installer net.framework
 AS8510 code example
All 3 items are available on the ams website as download
http://www.ams.com/eng/Support/Demoboards/Sensor-Interfaces/Data-Acquisition-FrontEnd/AS8510-Demo-Kit
5
Board Schematics, Layout and BOM
There is a 1x10 pin connector on the board which gives access to the interesting pins of the
AS8510. The connection diagram of this port is as follows:
www.ams.com
Revision 1 / 20/05/2014
page 3/4
Operational Manual: AS8510-DK
The 2x5 pin connector is a standard ATMEL ISP programming interface which is only
needed to install the initial firmware.
Firmware update can be done via an integrated bootloader (FBOOT in the firmware
package)
For usage of this bootloader see:
http://www.mikrocontroller.net/articles/AVR_Bootloader_FastBoot_von_Peter_Dannegger#
Brennen_des_eigetlichen_Programmes
The 1x3 connector is to determine whether the board is supplied via USB or via the ISP
adapter.
Further Notice:
To use the register tab you have to do a read first in order to get an initial set of values into
the program.
6
Advanced Usage
The demo provides a standard serial interface which can be accessed by any program with
serial interface capabilities such a Hyperterminal, Matlab or Simulink.
The interface presents an informational output if you print “?\n” to the serial device.
The standard functions are as follows:
0 - (re)configure device
1 - read device
2 - read internal temperature of device
3 - start continous read
4 - stop continous read
5 - start continous temp read
6 - stop continous temp read
7 - printout configuration registers
8 - write configuration registers #reg : #value \n
9 - timing read enter number of read cycles and press enter
The number has to be ended with a newline command “\n”
7
Ordering Information
Description
Price
AS8510 DEMOBOARD / #SAP: 990600426
$ 140
www.ams.com
Revision 1 / 20/05/2014
page 4/4