KBPC1, KBPC6 Series Vishay High Power Products Single Phase Rectifier Bridge, 3 A, 6 A FEATURES • Suitable for printed circuit board or chassis mounting • Compact construction • High surge current capability • Compliant to RoHS directive 2002/95/EC DESCRIPTION D-72 PRODUCT SUMMARY IO(AV) 3.0 A, 6.0 A VRRM 50 V to 1000 V The KBPC series of single phase rectifier bridge consists of four silicon junctions connected as a full bridge. These devices are intended for general use in industrial and consumer equipment. MAJOR RATINGS AND CHARACTERISTICS SYMBOL CHARACTERISTICS KBPC1 KBPC6 UNITS 3 6 A 50 Hz 50 125 60 Hz 55 137 IO IFSM I2 t VRRM 50 Hz 12.5 78 60 Hz 11.4 71 Range TJ A A2s 50 to 1000 V - 40 to 150 °C ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V PART NUMBER VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V VRMS, MAXIMUM RECOMMENDED RMS SUPPLY VOLTAGE V KBPC1005 KBPC6005 50 50 20 KBPC102 KBPC602 200 200 80 KBPC104 KBPC604 400 400 125 KBPC106 KBPC606 600 600 250 KBPC108 KBPC608 800 800 380 KBPC110 KBPC610 1000 1000 500 Document Number: 93585 Revision: 23-Dec-08 For technical questions, contact: [email protected] www.vishay.com 1 KBPC1, KBPC6 Series Single Phase Rectifier Bridge, 3 A, 6 A Vishay High Power Products FORWARD CONDUCTION PARAMETER SYMBOL Maximum DC output current IO TEST CONDITIONS KBPC1 KBPC6 TC = 50 °C, resistive or inductive load 3.0 6.0 TC = 50 °C, capacitive load 2.4 4.7 50 125 55 137 12.5 78 t = 10 ms, 20 ms Maximum peak one cycle, non-repetitive surge current IFSM t = 8.3 ms, 16.7 ms Following any rated load condition and with rated VRRM reapplied t = 10 ms t = 8.3 ms Initial TJ = TJ maximum 100 % VRRM reapplied 11.4 71 17.7 110 UNITS A Maximum I2t capability for fusing I2t t = 8.3 ms 16.1 1000 Maximum I2√t capability for fusing I2√t t = 0.1 ms to 10 ms, no voltage reapplied 177 1105 A2√s Maximum peak forward voltage per diode VFM IFM = 0.5 x IO, TJ = 25 °C 1.1 1.2 V TJ = 25 °C, 100 % VRRM 10 10 TJ = 150 °C, 100 % VRRM 1.0 1.0 Typical peak reverse leakage per diode t = 10 ms IRM Operating frequency range Maximum repetitive peak reverse voltage range A2 s mA f 40 to 1000 Hz VRRM 50 to 1000 V THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER SYMBOL Operating and storage temperature range KBPC1 TJ, TStg Thermal resistance, junction to case KBPC6 RthJC - Approximate weight 4.0 K/W 5 6 g 0.18 0.21 oz. 8 KBPC6... 3.5 Average Output Current (A) Average Output Current (A) °C - KBPC1... 3.0 Resistive, inductive load 2.5 2.0 Capacitive load 1.5 1.0 0.5 0.0 7 6 Resistive, inductive load 5 4 Capacitive load 3 2 1 0 0 93585_01 UNITS - 40 to 150 20 40 60 80 100 120 140 160 Maximum Allowable Case Temperature (°C) Fig. 1 - Case Temperature Ratings www.vishay.com 2 0 93585_02 20 40 60 80 100 120 140 160 Maximum Allowable Case Temperature (°C) Fig. 2 - Case Temperature Ratings For technical questions, contact: [email protected] Document Number: 93585 Revision: 23-Dec-08 KBPC1, KBPC6 Series 60 Maximum Peak Output Current (A) Maximum Peak Output Current (A) Single Phase Rectifier Bridge, 3 A, 6 A KBPC1... 50 From any rated load condition 40 30 20 10 0 10-2 93585_03 10-1 1 10 Pulse Train Duration (s) Vishay High Power Products 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 10-2 KBPC6... From any rated load condition 10-1 Fig. 3 - Non-Repetitive Surge Ratings 1 10 Pulse Train Duration (s) 93585_04 Fig. 4 - Non-Repetitive Surge Ratings CIRCUIT CONFIGURATION + IO(av) ~ ~ LINKS TO RELATED DOCUMENTS Dimensions Document Number: 93585 Revision: 23-Dec-08 www.vishay.com/doc?95250 For technical questions, contact: [email protected] www.vishay.com 3 Outline Dimensions www.vishay.com Vishay Semiconductors D-72 DIMENSIONS in millimeters (inches): KBPC6, KBPC8 15.75 (0.620) 14.75 (0.580) Ø 3.80 (Ø 0.150) 5.33 (0.210) 4.33 (0.170) ~ + 15.75 (0.620) 14.75 (0.580) 10.8 (0.425) 10.0 (0.394) ~ 25.4 (1.000) MIN. 10.8 (0.425) 10.0 (0.394) Ø 1.10 (Ø 0.043) Ø 0.90 (Ø 0.035) DIMENSIONS in millimeters (inches): KBPC1 15.7 (0.62) 16.7 (0.66) Ø 3.8 (Ø 0.15) Ø 4.2 (Ø 0.16) 5.5 (0.22) 6.5 (0.26) + ~ 15.7 (0.62) 16.7 (0.66) 10 (0.39) 11 (0.43) ~ 22 (0.87) MIN. 10 (0.39) 11 (0.43) Ø 0.7 (Ø 0.028) Ø 0.9 (Ø 0.035) Revision: 20-Jan-16 Document Number: 95250 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000